AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling to 5 Tons GAS FURNACES ML180UHE

Size: px
Start display at page:

Download "AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling to 5 Tons GAS FURNACES ML180UHE"

Transcription

1 PRODUCT SPECIFICTIONS GS FURNCES ML80UHE MERIT SERIES Upflow / Horizontal - High Efficiency lower Motor ulletin No July 208 Supersedes February 208 FUE - 80% Input - 44,000 to 32,000 tuh Nominal dd-on Cooling -.5 to 5 Tons MODEL NUMER IDENTIFICTION ML 80 UH 070 X E 36 Unit Type ML =Merit Series Stages = Single-Stage FUE 80 = 80% Configuration UH = Upflow/Horizontal Nominal Gas Heat Input 045 = 44,000 tuh 070 = 66,000 tuh 090 = 88,000 tuh 0 = 0,000 tuh 35 = 32,000 tuh Cabinet Width = 4-/2 in. = 7-/2 in. C = 2 in. D = 24-/2 in. Nominal dd-on Cooling Capacity 36 =.5-3 tons 48 = tons 60 = 3-5 tons lower E = High Efficiency Constant Torque lower Motor Low NO x X = Units meet California Nitrogen Oxides Standard (40ng/J) Indoor coils with the same letter designation will physically match the furnace.

2 FETURES J CONTENTS lower Data... 3 Dimensions - Furnace/Coil Combined Dimensions... 2 Dimensions - Horizontal Position... 0 F Dimensions - Upflow Position... 9 Features... 2 Gas Heat ccessories... 8 High ltitude Derate... 8 Installation Clearances... 7 Model Number Identification... Optional ccessories - Order Separately... 8 Optional ccessory Dimensions... G D L E C K I Specifications... 7 H NOTE - ML80UHE FURNCES RE NOT VILLE IN CND! WRRNTY Duralok luminized Steel Heat Exchanger - Limited twenty year warranty in residential applications, ten years in non-residential applications. ll other covered components - Limited five year warranty in residential applications, one year in nonresidential applications. Refer to Lennox Equipment Limited Warranty certificate included with equipment for details. PPROVLS Units are Certified by HRI. Units tested and rated according to US DOE test procedures and FTC labeling regulations. pproved by the California Energy Commission and meets California Nitrogen Oxides Standard (NOx) limits of 40 ng/j. ISO 900 Registered Manufacturing Quality System. lower data from unit tests conducted in Lennox Laboratory air test chamber. ML80UHE / Page 2 PPLICTIONS Input capacities of 44,000, 66,000, 88,000, 0,000 and 32,000 tuh. Energy efficiency (FUE) of 80%. Compact cabinet for upflow, horizontal-left or horizontalright applications. Utility room, alcove, closet, crawl space, basement or attic installation. Lennox add-on indoor coils, high-efficiency air cleaners and humidifiers can easily be added to furnace. Shipped factory assembled with all controls installed and wired. Ready for installation in upflow or horizontal right-hand position without any modifications. Horizontal left-hand position requires repositioning of pressure switch. Removable bottom seal panel shipped in place for side return air is easily removed for bottom/end return air applications. Each unit factory test operated to ensure proper operation.

3 FETURES C D E F G HETING SYSTEM Lennox Duralok Heat Exchanger ssembly Heavy gauge aluminized steel heat exchanger. Crimped seam clamshell type design. Designed for normal expansion and contraction. Minimum resistance to air flow. Heat exchanger has been laboratory life cycle tested in excess of industry standards. Compact size of heat exchanger permits low overall design of furnace cabinet. Inshot urners luminized steel inshot burners provide efficient, trouble-free operation. urner venturi mixes air and gas in correct proportion for proper combustion. urner assembly is removable from the unit as a single component for ease of service. SureLight Hot Surface Ignitor Tough, reliable, long-life, trouble-free performance. Silicon nitride ignitor. Cemented to steatite block for protection against current leakage. Ignition leads are constructed of nickel plated copper and are enclosed in high temperature Teflon insulation for dependable operation. Gas Control Valve 24 volt redundant combination gas control valve combines manual shut off switch (On-Off), automatic electric valve (dual) and gas pressure regulation into a compact combination control. Combustion ir Inducer Shaded pole heavy duty blower prepurges heat exchanger and safely vents flue products. Pressure switch proves blower operation before allowing gas valve to open. Operates only during heating cycle. Direct access allows inducer assembly to be rotated 90 clockwise or counterclockwise to facilitate easy vent attachment from either side of the cabinet in upflow applications and from the top in horizontal applications. Flame Rollout Switches (2) Manual reset switches are factory installed on burner box. Switches provides protection from abnormal operating conditions. H Limit Control utomatic reset, primary limit is accurately located on vestibule panel on all units. Optional ccessories High ltitude Pressure Switch Kit Required on most units for proper unit operation at altitudes from 4,50 to 7500 ft. Natural Gas to LPG/Propane Conversion Kit Required for field changeover from natural gas to LPG/ Propane. LPG/Propane to Natural Gas Conversion Kit Required for field changeover from LPG/Propane to natural gas. Vent daptor (Upflow pplications Only) llows venting through a masonry chimney without the need of a flue liner. Manual reset temperature sensor protects against abnormal operating conditions. Sensor wiring may be routed from either side of adaptor. Minimum winter design temperatures: 0 F when used with interior masonry chimneys. +5 F when used with exterior masonry chimneys. Refer to Winter Design Temperatures Map on page 6 for application information. lso refer to the installation instructions for detailed information. LOWER 6 in. (52 mm) 7 in. (78 mm) Power Saver Constant Torque lower Motor Programmable high efficiency multi-speed blower motor. y maintaining constant torque output, blower motor can deliver more uniform (but not constant) airflow over the static pressure range. Programmable multi-speed operation is achieved by the use of an ECM (Electronically Commutated Motor) motor. Leadless blower motor features simple plug-in connections. Motor is controlled by the Integrated Furnace Control. lower speeds are easily changed on the integrated furnace control. See lower Data tables. lower ssembly Lennox designed and built, direct drive blower. Each blower is statically and dynamically balanced as an assembly before installation in the unit. lower motor is resiliently mounted to blower assembly. lower is easily removed for servicing. ML80UHE / Page 3

4 FETURES I CONTROLS SureLight Integrated Furnace Control Control contains all necessary controls and relays to operate furnace. Combustion air inducer is operated by the integrated furnace control. Prior to ignition, a pre-purge cycle for 5 seconds is initiated. fter the main burners are turned off, a post-purge cycle for 5 seconds is run. Flame sensor assures safe and reliable operation. Should loss of flame occur the integrated furnace control will initiate 4 re-attempts at ignition before locking out unit operation for 60 minutes. Watchguard type circuit automatically resets ignition controls after one hour of continuous thermostat demand after unit lockout, eliminating nuisance calls for service. Fan control consists of adjustable blower timed-off delay (60, 90, 20, 80 seconds - factory setting 90 seconds) and fixed blower timed-on delay (30 seconds - heating, 2 seconds - cooling). For air-conditioning applications, blower is automatically energized on thermostat demand for cooling. Control has low speed continuous blower speed setting for humidifier or air cleaner operation. Two accessory terminals furnished for additional power supply requirements for 20 volt (less than amp) power humidifiers and powered air cleaners. One additional terminal is furnished for power supply requirements for 24V (less than 0.5 amp) low voltage accessories. Ignition control has single red LED to indicate status and as an aid in troubleshooting. Last five codes are stored in non-volatile memory (accessible by recall button on control) for servicing. 24 Volt Transformer Furnished and factory installed on outside of control box. 40V transformer has fuse wired in series. Field Wiring Make-up ox Furnished for line voltage wiring. Factory installed internally on left side of furnace. ox may be installed on right side of furnace. Optional ccessories lower Relay Kit (For Use With Two-Stage Outdoor Units) llows furnace blower speed changes when matched with two-stage air conditioners or heat pumps. Furnace Twinning Kit Required to operate two furnaces simultaneously. Kit consists of twinning relays, quick connect terminals and mounting hardware. Used for single-stage heating/single-stage cooling with a single-stage thermostat. Thermostat Thermostat (programmable/non-programmable) is not furnished with unit. See Thermostat bulletins in Controls Section and Lennox Price ook for selection. Night Service Kit Contains most commonly used service parts: Furnace Control Ignitor Flame sensor Gas valve Transformer FILTER (Not Furnished) Filter and provisions for external mounting must be field provided. Optional ccessories ir Filter and Rack Kit for Horizontal Return ir (End) pplications Washable or vacuum cleanable polyurethane frame type filter and external end return air rack available for field installation. Rack has filter door for easy filter servicing. Flanges on rack allow easy duct connection. See dimension drawing. ir Filter and Rack Kit for Upflow Side Return ir pplications - Not for use with Return ir ase Washable or vacuum cleanable polyurethane frame type filter and external side return air rack available for field installation. vailable in single and ten pack kits. Rack has filter door for easy filter servicing. Flanges on rack allow easy duct connection. Field installs on either side of unit cabinet. See dimension drawing. ML80UHE / Page 4

5 FETURES J K L CINET Low-profile, narrow width cabinet allows easy installation. Heavy-gauge, cold rolled steel construction. Pre-painted cabinet finish. Flue outlet on top of cabinet for upflow applications, can be relocated to either side of cabinet for horizontal applications. Flanges provided on supply air opening for ease of plenum connection or alignment with indoor coil. Insulated cabinet with foil faced insulation on sides and back of heating compartment. Sealed blower compartment. Inner blower compartment access panel seals blower compartment from air leakage. Complete service access. Safety interlock switch automatically shuts off power to unit when blower compartment access panel is removed. Gas piping and electrical inlets are provided in both sides of cabinet. Low Leakage Cabinet ll models have less than 2% air leakage and meet NSI/SHRE Standard Method of Test for Determining the ir Tightness of HVC Equipment. Return ir Entry: For bottom/end return-air entry for upflow/horizontal applications, remove furnished bottom seal panel from cabinet. For side return-air entry (upflow applications only), corners are marked on either side of cabinet for return air cut-outs. See dimension drawings. NOTE - 60C and 60D size units that require air volumes over 800 cfm must have one of the following:. Single side return air and Optional Return ir ase with transition that must accommodate required 20 x 25 x inch air filter to maintain proper velocity. 2. ottom return air. 3. Return air from both sides. 4. ottom and one side return air. See lower Performance Tables for additional information. Coil Match-up ll furnaces exactly match Lennox cased upflow indoor coils and horizontal indoor coils with same letter designation (,, C, D) in model number. No adaptor required. Engaging holes furnished on cabinet for alignment. Lennox uncased coils match furnaces without any overhang but require an optional adaptor base or field fabricated transition to match furnace opening. See coil bulletin for additional information. Optional ccessories Horizontal Suspension Kit Provides suspension of unit and indoor coil in horizontal applications. llows complete service access. Consists of corner mounted hanging brackets with vibration isolators, return air end support rail and hardware for assembly. Metal hanging straps must be field provided. Return ir ase field fabricated transition or Return ir ase is required when using an IQ product higher than 4-3/6 in. installed next to the unit and serviced from the front. IQ products higher than 20 in. require a field fabricated transition. ase must be used for 60C and 60D models with air volumes over 800 cfm in upflow applications when only one side return is required. Cabinet is shipped flat for easy field assembly and is pre-painted steel to match the furnace. See Dimension Drawing. High Performance Economizer(Commercial pplications Only) Designed for applications requiring outdoor air to be utilized in a commercial HVC system. llows the entry of fresh outdoor air for free cooling, reducing the requirement for mechanical cooling. Heavy gauge galvanized steel cabinet lined with thick fiberglass insulation. Mixed air sensor, outdoor air sensor and 24VC transformer furnished. pproved for California Title 24 building standards. SHRE compliant. See separate Product Specifications bulletin for additional information and available control and sensor options. ML80UHE / Page 5

6 99% WINTER DESIGN TEMPERTURES FOR THE CONTIGUOUS UNITED STTES 5 o F 0 o F 7 o F 27 o F 0 o F 5 o F 37 o F 0 o F 7 o F 27 o F 37 o F This map is a necessarily generalized guide to temperatures in the contiguous Unites States. Temperatures shown for areas such as mountainous regions and large urban centers may not be accurate. The data used to develop this map was taken from the 993 SHRE Fundamentals Handbook (Chapter 24, Table : Climate Conditions for the United States). Reprinted with permission from NFP 54: National Fuel Gas Code 999, National Fire Protection ssociation, Quincy, M This reprinted material is not the complete and official position of the National Fire Protection ssociation on the referenced subject, which is represented only by the standard in its entirety. ML80UHE / Page 6

7 SPECIFICTIONS Gas Model No. ML80UH045E36 ML80UH070E36 ML80UH090E48 Heating Model No. - Low Nox ML80UH045XE36 ML80UH070XE36 ML80UH090XE48 Performance HRI Ref. No. non X models X models FUE 80% 80% 80% Input - tuh 44,000 66,000 88,000 Output - tuh 36,000 53,000 72,000 Temperature rise range - F Gas Manifold Pressure (in. w.g.) 3.5 / / / 0.0 Nat. Gas / LPG/Propane High Static - in. w.g Connections Flue connection - in. round in. Gas pipe size IPS /2 /2 /2 Indoor lower Electrical Data Wheel nom. dia. x width - in. 0 x 8 0 x 0 0 x 0 Motor Type DC rushless DC rushless DC rushless Motor output - hp /2 /2 3/4 Tons of add-on cooling ir Volume Range - cfm Voltage 20 volts - 60 hertz - phase lower motor full load amps Maximum overcurrent protection Shipping Data lbs. - package SPECIFICTIONS Gas Model No. ML80UH090E60C ML80UH0E60C ML80UH35E60D Heating Model No. - Low Nox ML80UH0XE60C Performance HRI Ref. No. non X models X models FUE 80% 80% 80% Input - tuh 88,000 0,000 32,000 Output - tuh 72,000 90,000 07,000 Temperature rise range - F Gas Manifold Pressure (in. w.g.) 3.5 / / / 0.0 Nat. Gas / LPG/Propane High Static - in. w.g Connections Flue connection - in. round in. Gas pipe size IPS /2 /2 /2 Indoor lower Electrical Data Wheel nom. dia. x width - in. -/2 x 0 -/2 x 0 x Motor Type DC rushless DC rushless DC rushless Motor output - hp Tons of add-on cooling ir Volume Range - cfm Voltage 20 volts - 60 hertz - phase lower motor full load amps Maximum overcurrent protection Shipping Data lbs. - package NOTE - Filters and provisions for mounting are not furnished and must be field provided. nnual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces. INSTLLTION CLERNCES - INCHES (MM) UPFLOW POSITION Vent Type Type Type C Sides 0 (0) 0 (0) Rear 0 (0) 0 (0) Top (25) (25) Front 2-/4 (57) 2-/4 (57) Front (service/alcove) 24 (60) 24 (60) Floor Combustible Combustible Flue (25) 6 (52) NOTE ir for combustion must conform to the methods outlined in the National Fuel Gas Code (NFP 54/NSI-Z223.). NOTE In the U.S. flue sizing must conform to the methods outlined in the current National Fuel Gas Code (NFP 54/NSI-Z223.) or applicable provisions of local building codes. Left side requires 4 in. if single wall vent is used on 4-/2 in. cabinets, 2 in. on 7-/2 in. cabinets. HORIZONTL POSITION Vent Type Type Type C End 2 2 Rear 0 (0) 0 (0) Top 0 (0) 0 (0) Front 2-/4 (57) 2-/4 (57) Front (service) 24 (60) 24 (60) Floor Combustible Combustible Flue (25) 6 (52) NOTE ir for combustion must conform to the methods outlined in the National Fuel Gas Code (NFP 54/NSI-Z223.). NOTE In the U.S. flue sizing must conform to the methods outlined in the current National Fuel Gas Code (NFP 54/NSI-Z223.) or applicable provisions of local building codes. Line contact installation permissible between jacket top or sides and building joists. ML80UHE / Page 7

8 OPTIONL CCESSORIES - ORDER SEPRTELY Width Models Width Models C Width Models D Width Models CINET CCESSORIES Horizontal Suspension Kit - Horizontal only 5W0 5W0 5W0 5W0 Return ir ase - Upflow only 65W75 50W98 50W99 5W00 High Performance Economizer (Commercial Only) 0U53 0U53 0U53 0U53 CONTROLS lower Relay Kit (for two-stage outdoor units) 85W66 85W66 85W66 85W66 Furnace Twinning Kit 6W72 6W72 6W72 6W72 FILTERS ir Filter and Rack Kit Horizontal (end) 87L95 87L96 87L97 87L98 Size of filter - in. 4 x 25 x 8 x 25 x 20 x 25 x 25 x 25 x Side Return Single 44J22 44J22 44J22 44J22 Ten Pack 66K63 66K63 66K63 66K63 Size of filter - in. 6 x 25 x 6 x 25 x 6 x 25 x 6 x 25 x NIGHT SERVICE KIT Night Service Kit 84W47 84W47 84W47 84W47 VENTING Vent daptor 6 in. conn. size upflow applications only 8M79 8M79 8M79 8M79 Cleanable polyurethane, frame-type filter. GS HET CCESSORIES Input High ltitude Pressure Switch Kit Natural Gas to LPG/Propane Kit LPG/Propane to Natural Gas Kit Natural Gas High ltitude Orifice Kit ft ft ,000 ft ft ,000 ft ft ,000 ft. 045 No Change 80W52 80W5 K49 K44 73W8 73W No Change 80W52 80W5 K49 K44 73W8 73W No Change 80W52 80W5 K49 K44 73W8 73W37 0 No Change 80W52 80W52 K49 K44 73W8 73W37 35 No Change 80W52 80W5 K49 K44 73W8 73W37 HIGH LTITUDE DERTE NOTE - Units may be installed at altitudes up to 2000 ft. above sea level without any modifications. t altitudes above 2000 ft. units must be derated to match information in the shaded areas shown below. NOTE - This is the only permissible derate for these units. Gas Manifold Pressure (Outlet) in. w.g. Line Pressure - in. w.g. Input Feet Feet Feet 750-0,000 ft. Minimum Natural Gas LPG/ Propane Natural Gas LPG/ Propane Natural Gas LPG/ Propane Natural Gas LPG/ Propane Natural Gas LPG/ Propane Maximum Natural Gas High ltitude Orifice Kit required. ML80UHE / Page 8

9 DIMENSIONS - INCHES (MM) - UPFLOW POSITION NOTE - 60C and 60D size units that require air volumes over 800 cfm must have one of the following:. Single side return air and Optional Return ir ase with transition that must accommodate required 20 x 25 x inch (508 x 635 x 25 mm) air filter to maintain proper velocity. 2. ottom return air. 3. Return air from both sides. 4. ottom and one side return air. See lower Performance Tables for additional information. D FLUE OUTLET (Top) 3-/8 (79) SUPPLY IR OPENING 2 Flue outlet may be horizontal but furnace must be vented vertically 3 Optional External Side Return ir Filter Kit is not for use with the optional Return ir ase. 3 OPTIONL EXTERNL SIDE RETURN IR FILTER KIT (Either Side) 23-3/4 (603) 25 (635) TOP VIEW 9/6 (4) 3/4(9) Front Panel 3 (76) Right 6-3/4 (7) Left 3-/4 (83) 27-3/4 (705) 9-7/6 (494) 9/6 (4) 3 OPTIONL EXTERNL SIDE RETURN IR FILTER KIT (Either Side) 33 (838) 9-/8 (232) Right 8-5/8 (29) Left 5-3/8 (37) Right 2-3/6 (56) Left 2 FLUE OUTLET (Either Side) ELECTRICL INLET (Either Side) GS PIPING INLET (Either Side) 4-3/4 (375) 6 (406) ELECTRICL INLET (Either Side) 23 (584) Side Return ir Opening (Either Side) 4 (356) -/2 (38) -5/6 (49) 3/4 (9) C ottom Return ir Opening 3/4 (9) 5/8 (6) 3-/4 (83) 23-/2 (597) ottom Return ir Opening FRONT VIEW SIDE VIEW Model No. C D in. mm in. mm in. mm in. mm ML80UH045E36 4-/ / /4 2 ML80UH070E36 ML80UH090E48 ML80UH090E60C ML80UH0E60C 7-/ / / / / ML80UH35E60D 24-/ / /4 248 ML80UHE / Page 9

10 DIMENSIONS - INCHES (MM) - HORIZONTL POSITION Flue outlet may be from end but furnace must be vented vertically 9-/8 (232) Top 8-5/8 (29) ottom FLUE OUTLET (Top) 3 (76) LEFT-HND IR DISCHRGE GS PIPING INLET (Top or ottom) IR FLOW ELECTRICL INLET (Top or ottom) 3/4 (9) Front Panel 27-3/4 (705) 9/6 (4) FLUE OUTLET (End) 6-3/4 (7) TOP VIEW 33 (838) 5-3/8 (37) Top 2-3/6 (56) ottom 3/4 (9) 27-3/4 (705) 9/6 (4) 9-7/6 (494) SUPPLY IR OPENING D IR FLOW 4-/4 (08) C 23-/2 (597) RETURN IR OPENING END VIEW 3-/8 (79) FRONT VIEW RIGHT-HND IR DISCHRGE END VIEW ELECTRICL INLET (Top or ottom) IR FLOW GS PIPING INLET (Top or ottom) 6-3/4 (7) Flue outlet may be horizontal but furnace must be vented vertically FLUE OUTLET (Top) 3/4 (9) Front Panel 3 (76) 27-3/4 (705) 2-3/6 (56) Top 5-3/8 (37) ottom TOP VIEW 33 (838) 8-5/8 (29) Top 9-/8 (232) ottom FLUE OUTLET (End) 27-3/4 3-/8 (705) (79) 23-/2 (597) RETURN IR OPENING C 4-/4 (08) IR FLOW D 9-7/6 (494) SUPPLY IR OPENING 9/6 (4) END VIEW 3/4 (9) FRONT VIEW END VIEW 9/6 (4) Model No. C D in. mm in. mm in. mm in. mm ML80UH045E36 4-/ / /4 2 ML80UH070E36 ML80UH090E48 7-/ / /4 59 ML80UH090E60C ML80UH0E60C / / ML80UH35E60D 24-/ / /4 248 ML80UHE / Page 0

11 OPTIONL CCESSORY DIMENSIONS - INCHES (MM) HORIZONTL (END) FILTER KIT 5/8 (6) 24 3/4 (629) -/4 (32) 5/8 (6) RETURN IR OPENING 23 /2 (597) 5/8 (6) IR FLOW Furnace Cabinet Width Catalog Number in. mm in. mm 87L / L /4 425 C 87L /4 476 D 87L / /8 (6) SIDE VIEW IR FILTER (Furnished) FRONT VIEW Optional Return ir ase (Upflow pplications Only - For use with,, C and D cabinets) FURNCE FRONT IR FLOW INDOOR IR QULITY CINET (PCO, Filter Cabinet, etc.) IF SE IS USED WITHOUT IQ CINET, SINGLE RETURN IR PLENUM MUST COVER OTH UNIT ND RETURN IR SE OPENINGS 3-/4 (83) 7-/4 (84) 23 (584) Overall (Maximum) Unit side return air Opening 5-5/8 (43) Minimum (279) 2 Maximum 4 (356) SIDE RETURN IR OPENINGS (Either Side) 22-7/6 (570) Overall (Maximum) 4-/2 (368) Width (65W75) 7-/2 (446) Width (50W98) 2 (533) C Width (50W99) 24-/2 (622) D Width (5W00) OPTIONL RETURN IR SE 26-7/8 (683) 23 (584) SIDE VIEW 3/4 (9) NOTE- Optional Side Return ir Filter Kits are not for use with Optional Return ir ase. oth the unit return air opening and the base return air opening must be covered by a single plenum or IQ cabinet. Minimum unit side return air opening dimensions for units requiring 800 cfm or more of air (W x H): 23 x in. (584 x 279 mm). The opening can be cut as needed to accommodate plenum or IQ cabinet while maintaining dimensions shown. Side return air openings must be cut in the field. There are cutting guides stenciled on the cabinet for the side return air opening. The size of the opening must not extend beyond the markings on the furnace cabinet. 2 To minimize pressure drop, the largest opening height possible, up to 4 in. (356 mm), is preferred. ML80UHE / Page

12 DIMENSIONS - INCHES (MM) - FURNCE/COIL COMINED DIMENSIONS UPFLOW POSITION Model No C35/C37/CX35/CX38 Cased C35 Uncased C35/CX35 C37 CX38 in. mm in. mm in. mm in. mm C35/CX35-8/24 C35/CX35-8/24 C35/CX35-24 C35/CX35-24 C35/CX35-30 C35/CX35-30 C37-25 C / / / /8 97 CX38-25 CX / / / / CX / / C37-3 C37-3 C35/CX35-30/36 C37-36 C35/CX35-30/36 C37-36 C35/CX35-30/36C C37-36C C35/CX35-36 C35/CX35-36 C37-38 C37-38 CX38-3 CX38-3 CX38-36 CX38-36 CX38-36C CX38-38 CX / / / / / / / / / / / / C37-42 CX / / C35/CX35-48 C35/CX35-48C C37-43 C37-43C C37-48 C37-48C CX38-43 CX38-43C CX38-44/48 CX38-44/48C 27-/ / / / / / C35/CX35-49C C37-49C CX38-49C 29-/ / / /2 562 C35/CX35-50/60C C37-50/60C CX38-50/60C 27-/ / / / C37-60D CX38-60D 25-/ / CX35-60C C37-62C CX38-62C 3-/ / / /8 66 CX35-60D C37-62D CX38-62D 29-/ / (838) 33 (838) HORIZONTL POSITION Model No. in. mm in. mm CH33 CH / /2 384 CH33-24/30, CH33-42, 26-/ /2 5 CH33-36, CH33-36, CH33-36C, CH33-48C, CH33-60D CH33-44/48, CH33-62D 3-/ /2 638 CH33-50/60C, CH35 CH35-8, CH35-24, CH35-24, CH35-30, CH35-30, CH35-42, CH35-48, CH35-36, CH35-36, CH35-36C, CH35-42C, CH35-48C CH35-5C, CH35-60D 26-/ /2 5 3-/ /2 638 ML80UHE / Page 2

13 LOWER DT ML80UH045E36 PERFORMNCE (Less Filter) External Static Pressure in. w.g. ir Volume / Watts at Various lower Speeds High Medium-High Medium Medium-Low Low cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts ML80UH070E36 PERFORMNCE (Less Filter) External Static Pressure in. w.g. ir Volume / Watts at Various lower Speeds High Medium-High Medium Medium-Low Low cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts ML80UH090E48 PERFORMNCE (Less Filter) External Static Pressure in. w.g. ir Volume / Watts at Various lower Speeds High Medium-High Medium Medium-Low Low cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts N/ N/ ML80UHE / Page 3

14 LOWER DT ML80UH090E60C PERFORMNCE (Less Filter) ir Volume / Watts at Different lower Speeds ottom Return ir, Side Return ir from oth Sides or Return ir from ottom and One Side. External Static Pressure in. w.g. Single Side Return ir ir volumes in bold require Optional return ir ase and field fabricated transition to accommodate 20 x 25 x in. air filter in order to maintain proper air velocity. High Med-High Medium Med-Low Low High Med-High Medium Med-Low Low cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts ML80UH0E60C PERFORMNCE (Less Filter) ir Volume / Watts at Different lower Speeds ottom Return ir, Side Return ir with Return ir from oth Sides or Return ir from ottom and One Side. External Static Pressure in. w.g. Single Side Return ir ir volumes in bold require Optional return ir ase and field fabricated transition to accommodate 20 x 25 x in. air filter in order to maintain proper air velocity. High Med-High Medium Med-Low Low High Med-High Medium Med-Low Low cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts ML80UH35E60D PERFORMNCE (Less Filter) ir Volume / Watts at Different lower Speeds ottom Return ir, Side Return ir with Return ir from oth Sides or Return ir from ottom and One Side. External Static Pressure in. w.g. ML80UHE / Page 4 Single Side Return ir ir volumes in bold require Optional return ir ase and field fabricated transition to accommodate 20 x 25 x in. air filter in order to maintain proper air velocity. High Med-High Medium Med-Low Low High Med-High Medium Med-Low Low cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts

15

16 REVISIONS Sections Controls Specifications Description of Change dded Furnace Twinning Kit. dded HRI reference numbers. Visit us at For the latest technical information, Contact us at LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 208 Lennox Industries, Inc.

ML 1 80 UH 070 X E 36 B

ML 1 80 UH 070 X E 36 B PRODUCT SPECIFICTIONS GS FURNCES ML80UHE MERIT SERIES Upflow / Horizontal - High Efficiency Blower Motor Bulletin No. 2063 ugust 202 Supersedes January 202 FUE - 80% Input - 44,000 to 32,000 Btuh Nominal

More information

ML180UH. MERIT SERIES Upflow / Horizontal. AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons ML 1 80 UH 070 X P 36 B

ML180UH. MERIT SERIES Upflow / Horizontal. AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons ML 1 80 UH 070 X P 36 B E N G I N E E R I N G D T G S F U R N C E S ML80UH MERIT SERIES Upflow / Horizontal Bulletin No. 20590 June 20 Supersedes May 20 FUE - 80% Input - 44,000 to 32,000 Btuh Nominal dd-on Cooling - 2 to 5 Tons

More information

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor PRODUCT SPECIFICTIONS GS FURNCES EL80UHE ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor Bulletin No. 20660 February 208 Supersedes January 208 FUE - 80% Input - 44,000 to 32,000 Btuh Nominal

More information

MERIT SERIES Upflow / Horizontal

MERIT SERIES Upflow / Horizontal PRODUCT SPECIFICTIONS GS FURNCES ML80UH MERIT SERIES Upflow / Horizontal Bulletin No. 20590 February 208 Supersedes November 207 FUE - 80% Input - 44,000 to 32,000 Btuh Nominal dd-on Cooling - 2 to 5 Tons

More information

ELITE SERIES Upflow / Horizontal - Two-Stage Heat

ELITE SERIES Upflow / Horizontal - Two-Stage Heat PRODUCT SPECIFICTIONS GS FURNCES EL280UH ELITE SERIES Upflow / Horizontal - Two-Stage Heat ulletin No. 2063 June 205 Supersedes January 205 FUE - 80% Input - 66,000 to 32,000 tuh Nominal dd-on Cooling

More information

MERIT SERIES Up Flow / Horizontal

MERIT SERIES Up Flow / Horizontal G S F U R N C E S G40UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D T Bulletin No. 210278 December 2008 Supersedes May 2007 FUE 80% Input 44,000 to 154,000 Btuh Nominal dd on Cooling 1.5

More information

ELITE SERIES Downflow - High Efficiency Blower Motor

ELITE SERIES Downflow - High Efficiency Blower Motor PRODUCT SPECIFICATIONS GAS FURNACES EL80DFE ELITE SERIES Downflow - High Efficiency Blower Motor Bulletin No. 2066 July 208 Supersedes February 208 AFUE - 80% Input - 44,000 to 0,000 Btuh Nominal Add-on

More information

MERIT SERIES Downflow

MERIT SERIES Downflow PRODUCT SPECIFICATIONS GAS FURNACES ML80DF MERIT SERIES Downflow Bulletin No. 20643 February 208 Supersedes November 207 AFUE - 80% Input - 44,000 to 0,000 Btuh Nominal Add-on Cooling -.5 to 5 Tons MODEL

More information

ML180UHT (ce) MERIT SERIES Upflow / Horizontal 50HZ. Net Input to 34.8 kw Nominal Add-on Cooling to 17.

ML180UHT (ce) MERIT SERIES Upflow / Horizontal 50HZ. Net Input to 34.8 kw Nominal Add-on Cooling to 17. PRODUCT SPECIFICTIONS GS FURNCES ML80UHT (ce) MERIT SERIES Upflow / Horizontal 50HZ ulletin Number 49060 June 205 Supersedes June 203 Net Input - 7.4 to 34.8 kw Nominal dd-on Cooling - 0.6 to 7.6 kw MODEL

More information

ML 1 93 UH 070 x P 36 B

ML 1 93 UH 070 x P 36 B PRODUCT SPECIFICTIONS GS FURNCES ML93UH MERIT SERIES Upflow / Horizontal Bulletin No. 20588 October 202 Supersedes ugust 202 FUE - 93% Input - 44,000 to 32,000 Btuh Nominal dd-on Cooling - 2 to 5 Tons

More information

MERIT SERIES Upflow / Horizontal

MERIT SERIES Upflow / Horizontal PRODUCT SPECIFICTIONS GS FURNCES ML9UH MERIT SERIES Upflow / Horizontal Bulletin No. 0588 May 05 Supersedes January 05 FUE - 9% Input - 44,000 to,000 Btuh Nominal dd-on Cooling - to 5 Tons MODEL NUMBER

More information

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower P R O D U C T S P E C I F I C AT I O N S G A S F U R N A C E S SL280DFV DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Blower Bulletin No. 20576 December 200 Supersedes July 200

More information

MERIT SERIES Upflow / Horizontal

MERIT SERIES Upflow / Horizontal PRODUCT SPECIFICTIONS GS FURNCES ML9UH MERIT SERIES Upflow / Horizontal Bulletin No. 0588 March 08 Supersedes February 08 FUE - 9% Input - 44,000 to,000 Btuh Nominal dd-on Cooling - to 5 Tons MODEL NUMBER

More information

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2. P R O D U C T S P E C I F I C AT I O N S G A S F U R N A C E S G6MP ELITE Series Multi-Position - Two-Stage Heat Bulletin No. 038 August 009 Supersedes December 008 AFUE - Up to 95% Input - 44,000 to 3,000

More information

MERIT SERIES Upflow / Horizontal

MERIT SERIES Upflow / Horizontal PRODUCT SPECIFICATIONS GAS FURNACES ML95UH MERIT SERIES Upflow / Horizontal Bulletin No. 059 March 08 Supersedes February 08 AFUE - 95% Input - 44,000 to,000 Btuh Nominal Add-on Cooling - to 5 Tons MODEL

More information

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor PRODUCT SPECIFICATIONS GAS FURNACES EL95UHE ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor Bulletin No. 065 March 08 Supersedes February 08 AFUE - 95% Input - 0,000 to,000 Btuh Nominal

More information

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2. G A S F U R N A C E S G61MP ELITE SERIES Multi Position Two Stage Heat E N G I N E E R I N G D A T A Bulletin No. 210382 September 2006 Supersedes August 2006 AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal

More information

MERIT SERIES Downflow

MERIT SERIES Downflow PRODUCT SPECIFICATIONS GAS FURNACES ML95DF MERIT SERIES Downflow Bulletin No. 06 February 08 Supersedes November 07 MODEL NUMBER IDENTIFICATION AFUE - 95% Input - 44,000 to 0,000 Btuh Nominal Add-on Cooling

More information

Heating Capacity - 23,700 to 220,000 Btuh Nominal Add-On Cooling - 2 to 5 Tons WATER HEATING / BOILERS CBWMV. Residential Hot Water Heat Air Handler

Heating Capacity - 23,700 to 220,000 Btuh Nominal Add-On Cooling - 2 to 5 Tons WATER HEATING / BOILERS CBWMV. Residential Hot Water Heat Air Handler WTER HETING / OILERS CWMV PRODUCT SPECIFICTIONS Residential Hot Water Heat ir Handler ulletin No. 0434 ugust 05 Supersedes June 04 Heating Capacity - 3,700 to 0,000 tuh Nominal dd-on Cooling - to 5 Tons

More information

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Two-Stage Heat - Variable Speed Blower

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Two-Stage Heat - Variable Speed Blower PRODUCT SPECIFICATIONS GAS FURNACES SL80UHV DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Two-Stage Heat - Variable Blower Bulletin No. 0600 February 08 Supersedes November 07 MODEL NUMBER IDENTIFICATION

More information

8+* Bulletin No November 1997

8+* Bulletin No November 1997 ENGINEERING DATA VALUE 80Z UP-FLOW/HORIZONTAL GAS FURNACES *80.0 to 80.5% A.F.U.E. 45,000 to 20,000 Btuh (3.2 to 32.2 kw) Input Heating Capacity -/2 thru 6 Tons (3.5 thru 2. kw) Nominal Add-on Cooling

More information

DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower PRODUCT SPECIFICATIONS GAS FURNACES SL80DFV DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Blower Bulletin No. 060 November 07 Supersedes August 05 MODEL NUMBER IDENTIFICATION SL

More information

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications ENGINEERING DATA Typical Applications G20RE and G20RXE WhisperHeat DOWN-FLO GAS FURNACES *78.0% A.F.U.E. 50,000 to 150,000 Btuh Input Add-On Cooling 2 thru 5 Nominal Tons *Isolated Combustion System rating

More information

Heavy Duty Transformer. Low Voltage Circuit Breaker. Visit us at For the latest technical information,

Heavy Duty Transformer. Low Voltage Circuit Breaker. Visit us at   For the latest technical information, ENGINEERING DT Duralok Plus luminized Steel Heat Exchanger Pressure es Factory installed Field Wiring Make Up Box can be installed on either side Tool Less Entry Sight Glass Terminals for ccessory Connections

More information

13 GEP A L P - 1 A

13 GEP A L P - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800

More information

MERIT SERIES Downflow

MERIT SERIES Downflow PRODUCT SPECIFICATIONS GAS FURNACES ML9DF MERIT SERIES Downflow Bulletin No. 0589 March 09 Supersedes September 08 AFUE - 9% Input - 44,000 to 0,000 Btuh Nominal Add-on Cooling - to 5 Tons MODEL NUMBER

More information

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0204 L2 Revised 11 2006 G60UH(X) G60UH(X) SERIES UNITS G60UH(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with

More information

DuralokPlus Aluminized Steel Heat Exchanger G 32 V

DuralokPlus Aluminized Steel Heat Exchanger G 32 V ENGINEERING DATA GAS FURNACES G32V DAVE LENNOX SIGNATURE COLLECTION Up Flow Two Stage Heat Variable Speed Blower AFUE up to 94.2% Input 75,000 to 125,000 Btuh (22.0 to 36.6 kw) Add on Cooling 2 to 5 Tons

More information

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120 P R O D U C T S P E C I F I C AT I O N S O I L F U R N A C E S OHR23 ELITE SERIES Horizontal/Downflow ulletin No. 20097 February 20 Supersedes October 200 AFUE - Up to 83.5% Input - 05,000 to 54,000 tuh

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh PRODUCT SPECIFICATIONS GAS UNIT HEATERS / DUCT FURNACES TU T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ Bulletin No. 20402 November 207 Supersedes November 206

More information

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0804 L2 Revised 05 05 2008 G71MPP G71MPP SERIES UNITS G71MPP series units are high efficiency multi position (upflow, downflow, horizontal right and left) gas furnaces equipped

More information

G34M Bulletin #69/ August 2003

G34M Bulletin #69/ August 2003 ENGINEERING DATA G34M MULTI POSITION GAS FURNACE 12.4 to 31.0 kw Output 52.7 to 131.9 Mj Input 3.5 to 17.6 kw Nominal Add-on Cooling GAS FURNACES 50 Hz G34M Bulletin #69/490045 August 2003 Typical Applications

More information

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh GAS UNIT HEATERS / DUCT FURNACES LF24 COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ PRODUCT SPECIFICATIONS Bulletin 2008 July 206 Supersedes October 20 Steady-State Efficiency - up to 8% Input

More information

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0204 L2 Revised 09 2006 G60UH(X) G60UH(X) SERIES UNITS G60UH(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with

More information

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b PRODUCT SPECIFICATIONS OIL FURNACES El083b ELITE SERIES Lo-Boy Bulletin No. 20629 February 209 Supersedes July 202 MODEL NUMBER IDENTIFICATION el O 83 bf 0/4 p 60 AFUE - 83% Heating Input - 0,000 to 5,000

More information

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0124 L11 Revised 11 2006 G60UHV(X) G60UHV(X) SERIES UNITS G60UHV(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with

More information

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Variable Capacity - Variable Speed Blower

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Variable Capacity - Variable Speed Blower PRODUCT SPECIFICATIONS GAS FURNACES SLP98UHV DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Variable Capacity - Variable Speed Blower Bulletin No. 20577 March 208 Supersedes February 208 MODEL

More information

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh HEATERS / BOILERS GWB8-E PRODUCT SPECIFICATIONS Gas-Fired Hot Water Boiler Bulletin No. 065 September 0 Supersedes Bulletin No. 06 AFUE up to 83.9% Heating Input 50,000 to 99,000 Btuh MODEL NUMBER IDENTIFICATION

More information

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 1029 L7 SLP98UHV SLP98UHV SERIES UNITS SLP98UHV series units are high efficiency upflow, horizontal right and left) gas furnaces equipped with variable capacity gas valve, variable

More information

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower PRODUCT SPECIFICATIONS OIL FURNACES sl085bv DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower Bulletin No. 0677 August 05 Supersedes September 04 AFUE - Up to 87% Heating Input - 79,000 to

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGF1TA 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 80+ Upflow/Horizontal 2 Stage Gas Furnace with Variable Speed Blower 2 10 YEAR WARRANTY WORRY-FREE

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PGF1TE 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 95.1 AFUE Direct Vent or Non Direct Vent Condensing Furnace 10 YEAR WARRANTY WORRY-FREE PERFORMANCE

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0

More information

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E WATER HEATERS / BOILERS -E PRODUCT SPECIFICATIONS Gas-Fired Steam Boiler Bulletin No. 20653 September 202 Supersedes Bulletin No. 20263 AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh MODEL NUMBER

More information

AFUE 95% Heating Input 50,000 to 200,000 Btuh

AFUE 95% Heating Input 50,000 to 200,000 Btuh PRODUCT SPECIFICATIONS WATER HEATERS / BOILERS GWM-IE Gas-Fired, Modulating, Condensing, Wall Hung Hot Water Boiler Bulletin No. 210650 March 2018 Supersedes December 2015 AFUE 95% Heating Input 50,000

More information

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace XL 95 TUH2B060A936VA, TUH2B080A92VA, TUH2C100A98VA, TUH2D1A960VA, TDH2B060A936VA, TDH2B080A92VA, TDH2C100A98VA, TDH2D1A960VA

More information

GSR21Q PULSE21 SERIES

GSR21Q PULSE21 SERIES GSR21Q PULSE21 SERIES ENGINEERING DATA HORIZONTAL/DOWN-FLOW GAS FURNACES HORIZONTAL UNIT HEATERS AND DOWN-FLOW MOBILE HOME UNITS *91.7% to 95.3% A.F.U.E. 50,000 to 100,000 Btuh (14.7 to 29.3 kw) Input

More information

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES P R O D U C T S P E C I F I C AT I O N S W A T E R H E A T E R S / B O I L E R S CONSERVATOR Gas-Fired Steam Boiler Bulletin No. 20263 October 200 Supersedes September 2008 AFUE up to 82.7% Heating Input

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGF1RA Series M1010 Product Line High Efficiency / Upflow / Horizontal Gas Furnace Induced Draft - 80+ AFUEurnace 2 10 YEAR WARRANTY WORRY-FREE PERFORMANCE 5 YEAR DEPENDABILITY

More information

GSR21Q GAS FURNACES EXISTING NEG EXISTING NEG ENGINEERING DATA HORIZONTAL POSITION. Typical Applications DOWN-FLO POSITION

GSR21Q GAS FURNACES EXISTING NEG EXISTING NEG ENGINEERING DATA HORIZONTAL POSITION. Typical Applications DOWN-FLO POSITION ENGINEERING DATA GSR21Q PULSE21 SERIES HORIZONTAL/DOWN-FLO GAS FURNACES HORIZONTAL UNIT HEATERS AND DOWN-FLO MOBILE HOME UNITS *91.7% to 95.3% A.F.U.E. 50,000 to 100,000 Btuh Input Add-On Cooling 1-1/2

More information

FG7T (C and L Series)

FG7T (C and L Series) TECHNICAL SPECIFICATIONS FG7T (C and L Series) WARRANTY Smartlite Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The

More information

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh HEATERS / BOILERS GWB8-E Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 065 July 06 Supersedes September 05 AFUE up to 83.9% Heating Input 50,000 to 99,000 Btuh MODEL NUMBER IDENTIFICATION

More information

LF24. UNIT HEATERS Horizontal - 60 HZ. Thermal Efficiency - up to 80.5% Input - 100,000 to 390,000 Btuh LF A MODEL NUMBER IDENTIFICATION

LF24. UNIT HEATERS Horizontal - 60 HZ. Thermal Efficiency - up to 80.5% Input - 100,000 to 390,000 Btuh LF A MODEL NUMBER IDENTIFICATION E N G I N E E R I N G D ATA G A S U N I T H E A T E R S / D U C T F U R N A C E S LF4 UNIT HEATERS Horizontal - 60 HZ Bulletin. 0000 June 0 Supersedes February 0 Front View Tubular Heat Exchanger Thermal

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 060 March 05 Supersedes November 0 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0 kw

More information

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES SIZES AVAILABLE: 024045 through 060155 EFFICIENCY: The GB1AAV Induced-Combustion Gas Furnace provides the efficiency customers want with 80% Annual Fuel Utilization Efficiency (AFUE). IGNITION: The field-proven

More information

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE). This document was created with FrameMaker 4.0.4 SIZES AVAILABLE: 024065 through 060150 EFFICIENCY: IGNITION: HEAT EXCHANGER: CONTROL BOARD: The GA1A Induced-Combustion Gas Furnace provides the efficiency

More information

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS KG6TE Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 95.1 Upflow/Horizontal The high effi ciency 2-Stage gas furnace

More information

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A Upflow/Horizontal 2-Stage, Communicating Speed Gas Furnace XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D1ACV52A TUD2D140ACV52A TDD2B060ACV32A TDD2B080ACV32A TDD2C100ACV52A

More information

G51MP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G51MP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0307 L5 Revised 11 2006 G51MP SERIES UNITS G51MP G51MP series units are high efficiency multiple position (upflow, downflow, horizontal left and horizontal right) gas furnaces

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGC2T (C and L) Series SmartStart M1200 Product Line Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces 95.1 AFUE Input 60,000-120,000

More information

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS KG6RC Series High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/ Horizontal Gas Furnace Induced Draft - 92+ AFUE Input 40,000-120,000 Btuh The high effi ciency

More information

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa) 80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Series B approved for Twinning applications (0902116, 1002122, and 1352422) with accessory (order separately) Supports two stage cooling

More information

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV Upflow/Horizontal 2-Stage, Communicating Speed Gas Furnace Platinum SV AUD2B060ACV32A AUD2B080ACV32A AUD2C080ACV42A AUD2B100ACV32A AUD2C100ACV52A AUD2D120ACV52A AUD2D140ACV52A Two-Stage Fan Assisted Combustion

More information

G60DFV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60DFV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0211 L3 Revised 09 2006 G60DFV(X) G60DFV(X) SERIES UNITS G60DFV series units are mid efficiency gas furnaces used for downflow applications only, manufactured with Lennox Duralok

More information

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS FG6T(C,L) Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 92+ Upflow/Horizontal 90+ Downflow The high effi ciency 2-Stage

More information

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace XT 80 TUDA00A9H2B, TUDB060A9H3B TUDB080A9H3B, TUDC080A9HB TUDB00A9H3B, TUDC00A9H5B TUDDA9H5B, TUDD0A9H5B TDDB060A9H3B, TDDB080A9H3B TDDC00A9H5B,

More information

EL195UH WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. EL195UH SERIES UNITS

EL195UH WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. EL195UH SERIES UNITS Corp. 1101 L1 Service Literature Revised 03/2011 EL195UH EL195UH series units are high efficiency gas furnaces manufactured with Lennox DuralokPlus aluminized steel clamshell type heat exchangers, with

More information

Product Data. CBLAAA LOW-BOY OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES 140

Product Data. CBLAAA LOW-BOY OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES 140 CBL LOW-BOY OIL FURNCE INPUT RTES: 70,000 thru 154,000 BTUH SERIES 140 Product Data THE LTEST IN OIL FURNCE TECHNOLOGY 96280 The model CBL combines high efficiency and quiet operation with oil heating

More information

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING DIRECT OR NON -DIRECT VENT 4-WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct Vent furnace S

More information

G6RC Series TECHNICAL SPECIFICATIONS

G6RC Series TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS G6RC Series High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/ Horizontal Gas Furnace Induced Draft - 92+ AFUE Input 40,000-120,000 Btuh The high effi ciency upfl

More information

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh PA C KA G E D G A S / E L E C T R I C LRP14GE Residential - R-410A Bulletin No. 210720 November 2016 P R O D U C T S P E C I F I C AT I O N S Supersedes June 2016 SEER - 14.00 AFUE - 81% 2 to 5 Tons Cooling

More information

Downflow/Horizontal Right Induced Draft Gas Furnace

Downflow/Horizontal Right Induced Draft Gas Furnace Downflow/Horizontal Right Induced Draft Gas Furnace American Standard 80 ADE1A060A9361A, ADE1B060A9361A ADE1B080A951A, ADE1B100A951A ADE1C100A9601A, ADE1D120A9601A Single-Stage Fan Assisted Combustion

More information

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh WATER HEATERS / BOILERS COWB3 Oil-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 0654 March 08 Supersedes September 05 AFUE up to 85.% Heating Input 05,000 to 45,000 Btuh MODEL NUMBER IDENTIFICATION

More information

MERIT SERIES Up Flow / Horizontal

MERIT SERIES Up Flow / Horizontal A I R H A N D L E R S CB26UH / CBX26UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D A T A Bulletin No. 210429 December 2006 Supersedes November 2006 Nominal Capacity 1.5 to 5 Tons Optional

More information

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 TUC1B00A921A, TUC1B060A9361A TUC1B080A921A, TUC1C100A981A TUC1D100A9601A, TUC1D1A9601A Single-Stage Fan Assisted Combustion System PUB. NO. 22-1669-15

More information

Corp L12 Revised G24M SERIES UNITS

Corp L12 Revised G24M SERIES UNITS Service Literature G24M series units are mid efficiency gas furnaces manufactured with tubular steel heat exchangers formed of aluminized steel. G24M units are available in heating capacities of 45,000

More information

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION PA C KA G E D H E AT P U M P LRP4DF Dual-Fuel Residential - R-40A Bulletin No. 20722 November 206 P R O D U C T S P E C I F I C AT I O N S Supersedes October 206 SEER - 4.00 HSPF - 8.00 AFUE - 8% 2 to

More information

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace XR 95 TUHB00A92C, TUHB060A936C, TUHB080A92C, TUHC080A960C, TUHC00A98C, TUHD00A960C, TUHDA960C, TDHB00A92C, TDHB065A92C,

More information

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL 25--21--65 Representative photo only, some models may vary in appearance. MANUFACTURED FOR NATURAL GAS CONVERTIBLE TO (LP) PROPANE GAS NOTE: These

More information

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90 TUX060, 080, 100, 120R TDX060, 080, 100, 120R Direct Vent with Variable Speed Inducer PUB. NO. 22-1705-02-1202

More information

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES 036-1354-001 Rev. D (110) Heating TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE NATURAL GAS 37-111 MBH OUTPUT Air Conditioning EFFICIENCY RATING

More information

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner XV80i TUD2B060AFV32A, TUD2B080AFV32A, TUD2C080AFV42A, TUD2B100AFV32A, TUD2D120AFV52A 2009 Trane All Rights Reserved

More information

Upflow/Horizontal Condensing, Gas-Fired Furnace

Upflow/Horizontal Condensing, Gas-Fired Furnace Upflow/Horizontal Condensing, Gas-Fired Furnace TDD-D-1 90% Furnace AUC1B00A921A, AUC1B060A9361A AUC1B080A921A, AUC1C100A981A AUC1D100A9601A, AUC1D120A9601A Single-Stage Fan Assisted Combustion System

More information

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES FORM NO. G11-489 REV. 2 Supersedes Form No. G11-489 Rev. 1 GAS FURNACES RGPR- SERIES ECM Equipped Models with Input Rates from 50,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single Phase [15 to 37 kw] (U.S.

More information

RG7D 1-Stage Heat Series

RG7D 1-Stage Heat Series TECHNICAL SPECIFICATIONS RG7D 1-Stage Heat Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace

More information

G41UF WARNING. Service Literature G41UF SERIES UNITS. Table of Contents

G41UF WARNING. Service Literature G41UF SERIES UNITS. Table of Contents Service Literature Corp. 0303 L2 Revised 10 2004 G41UF SERIES UNITS G41UF G41UF series units are high efficiency upflow gas furnaces manufactured with Lennox DuralokPlus aluminized primary and stainless

More information

JE Series Cast Iron Commercial Natural Gas Steam Boiler Submittal/Specifications

JE Series Cast Iron Commercial Natural Gas Steam Boiler Submittal/Specifications JE Series Cast Iron Commercial Natural Gas Steam Boiler Submittal/Specifications Engineer: Project Name: Project Location: Contractor: PPLICTION: Modular Gas Fired Steam heating boiler for indoor installations.

More information

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG: Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B080U4PSAA Note: Graphics in this document are

More information

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG: Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B040U3PSAA Note: Graphics in this document are

More information

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3 FORM NO. G66-538 REV. 4 Supersedes Form No. G66-536 Rev. 3 W95T- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] MULTI-POSITION GAS FURNACES Features 95% residential gas furnace

More information

ELITE SERIES Downflow - Two-Stage Heating - Variable Speed Blower

ELITE SERIES Downflow - Two-Stage Heating - Variable Speed Blower PRODUCT SPECIFICATIONS GAS FURNACES EL96DFV ELITE SERIES Downflow - Two-Stage Heating - Variable Speed Blower Bulletin No. 060 March 09 Supersedes September 08 MODEL NUMBER IDENTIFICATION EL 96 DF 070

More information

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE AUXB00A92A, AUXB060A92A, AUXB060A936A, AUXB080A92A, AUXB080A92A, AUXC080A960A, AUXC00A936A,

More information

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80 Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80 TUDA00A92B, TUDA00A930B, TUDA060A92B, TUDA060A936B, TUDB060A936B, TUDB080A92B, TUDB080A936B, TUDB080A98B, TUDC080A960B,

More information

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80 Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80 TDD-D- TUDA00A92A, TUDA00A930A, TUDA060A92A, TUDA060A936A, TUDB060A936A, TUDB080A92A, TUDB080A936A, TUDB080A98A, TUDC080A960A,

More information

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G11-490 GAS FURNACES RGLR- SERIES ECM Equipped Models with Input Rates from 75,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single-Phase [22 to 37 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat) ENGINEERING DATA COILS BLOWER COIL UNITS B24/C22/24 B24 SERIES ADD-ON BLOWER UNITS UP-FLO DOWN-FLO HORIZONTAL WITH C22FC/CR22/CH22 & C24FC/CH24 COILS 1-1/2 Thru 5 Ton (5.3 thru 17.6 kw) Capacity 6,400

More information

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH FORM NO. G11-508 Supersedes Form No. G11-508 GAS FURNACES RGLE- SERIES ECM Equipped Models with Input Rates from 75,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single-Phase [22 to 37 kw] (U.S. & Canadian Models)

More information

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG: Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B080U3PSAA Note: Graphics in this document are

More information

Upflow/ Downflow Horizontal Right or Left Gas-Fired Furnace

Upflow/ Downflow Horizontal Right or Left Gas-Fired Furnace Upflow/ Downflow Horizontal Right or Left Gas-Fired Furnace Freedom 80 AUD2A00A922A, AUD2A060A9362A, AUD2B060A9362A, AUD2B080A9362A, AUD2B080A982A, AUD2B00A9362A, AUD2C00A982A, AUD2C00A9602A, AUD2D00A9602A,

More information