Design Standards Manual
|
|
- Ashlie Byrd
- 5 years ago
- Views:
Transcription
1 Design Standards Manual Table of Contents: Part III (Divisions 1-32) Section No. Title Revision DIVISION 1: GENERAL REQUIREMENTS Construction Waste Management 05/ HVAC Commissioning Requirements 05/07 DIVISION 02: EXISTING CONDITIONS Maintenance of Existing Conditions 10/ Common Work Results for Existing Conditions - RESERVED Schedules for Existing Conditions 10/ Commissioning of Existing Conditions - RESERVED Surveys 10/ Existing Conditions Assessment 10/ Environmental Assessment 10/ Existing Material Assessment 10/ Hazardous Material Assessment 10/ Geophysical Investigations 10/ Geotechnical Investigations 10/ Demolition 10/ Selective Demolition of Roofing 10/ Removal and Salvage of Construction Materials 10/ Site Remediation 10/ Remediation Soil Stabilization RESERVED Site Containment RESERVED Snow Control RESERVED Contaminated Site Material Removal 10/ Removal and Disposal of Contaminated Soils RESERVED Hazardous Waste Recovery Processes RESERVED Underground Storage tank Removal 10/ Water Remediation 10/ Groundwater Treatment RESERVED
2 Water Decontamination RESERVED Facility Remediation 10/ Transportation and Disposal of Hazardous Materials RESERVED Asbestos Remediation 10/ Removal of Asbestos Containing Roofing Material 10/ Lead Remediation RESERVED Polychlorinated Biphenyl Remediation RESERVED Mold Remediation RESERVED Hazardous Waste Drum Handling - RESERVED DIVISION 3: CONCRETE Cast-in-Place Concrete 05/ Lightweight Concrete Roof Insulation 05/07 DIVISION 4: MASONRY Cast Stone 05/ Unit Masonry Assemblies 05/ Masonry Restoration and Cleaning 05/07 DIVISION 5: METALS Structural Steel Framing 04/ Steel Decking 04/ Cold-Formed Metal Framing 04/ Metal Fabrications 04/ Metal Railings 04/17 DIVISION 6: WOOD AND PLASTICS General 08/ Timber Trusses 08/ Finish Carpentry 08/ Architectural Woodwork 08/00 DIVISION 7: THERMAL & MOISTURE PROTECTION Dampproofing and Waterproofing 01/12
3 07175 Water Repellent Coatings 01/ Roof insulation and Overlay Boards 01/ Exterior Insulation and Finish Systems 01/ Slate Shingles 01/ Metal Roof Panels 01/ Roofing General 01/ Metal Fasciae and Copings 01/ Roof Access 01/ Skylights 01/ Sealants 01/12 DIVISION 8: OPENINGS Metal Doors and Frames 06/ Wood Doors 06/ Entrances and Storefronts 06/ Windows 06/ Security Window Screens 06/ Hardware 06/ Automatic Door Operators 06/ Access Control System 06/ Louvers and Vents 06/18 DIVISION 9: FINISHES Acoustical Panel Ceilings 05/ Resilient Floor Tile 05/ Carpeting 05/ Painting 05/08 DIVISION 10: SPECIALTIES Signage 06/ Toilet Compartments 06/ Toilet, Bath and Laundry Accessories 06/ Fire Protection Specialties 06/18 DIVISION 11: EQUIPMENT Food Service Equipment 11/15
4 Laboratory Fume Hoods 11/15 DIVISION 12: FURNISHINGS Laboratory Casework 05/ Floor Mats and Frames 05/ Horizontal Louver Blinds 05/ Vertical Louver Blinds 05/07 DIVISION 13: SPECIAL CONSTRUCTION Elevated Water Storage Tanks RESERVED Surface Water Storage Tanks RESERVED Fire Alarm 06/ Fire Suppression Systems 06/ Fire Suppression Piping RESERVED Fire Pumps RESERVED Electric-Drive, Centrifugal Fire Pumps RESERVED Diesel-Drive, Centrifugal Fire Pumps RESERVED Electric-Drive, Vertical-Turbine Fire Pumps RESERVED Diesel-Drive, Vertical-Turbine Fire Pumps RESERVED Foam Fire-Extinguishing RESERVED Clean-Agent Extinguishing Systems RESERVED DIVISION 14: CONVEYING SYSTEMS Elevators 08/00 DIVISION 22 PLUMBING Domestic Water Piping RESERVED Domestic Water Piping Specialties 06/ Domestic Water Pumps RESERVED Domestic Water Packaged Booster Pumps RESERVED Facility Potable Water Storage Tanks RESERVED Sanitary Waste and Vent Piping 06/ Sanitary Waste Piping Specialties RESERVED Sanitary Sewerage Pumps RESERVED
5 Facility Storm Drainage Piping 06/ Sump Pumps RESERVED General Service Compressed Air Piping RESERVED General Service Compressed Air Valves RESERVED General Service Packaged Air Compressors and Receivers RESERVED Domestic Water Softeners RESERVED Domestic Water Filtration Equipment RESERVED Electric Domestic Water Heaters 06/ Fuel-Fired Domestic Water Heaters 06/ Domestic Water Heat Exchangers 06/ Plumbing Fixtures 06/ Emergency Plumbing Fixtures 06/ Drinking Fountains and Water Coolers 06/ Compressed Air Piping for Laboratory and Health Care Facilities RESERVED Compressed Air Equipment for Laboratory and Health Care Facilities RESERVED Vacuum Piping for Laboratory and Health Care Facilities RESERVED Gas Piping for Laboratory and Health Care Facilities RESERVED Chemical Waste Systems for Laboratory and Health Care Facilities RESERVED Chemical Waste Tanks RESERVED Processed Water Piping for Laboratory and Health Care Facilities RESERVED DIVISION 23 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) General 06/ HVAC Air Distribution System Cleaning 06/ Common Work Results for HVAC 06/ Common Motor Requirements for HVAC RESERVED Expansion Fittings and Loops for HVAC Piping 06/ Meters and Gages for HVAC Piping 06/ General Duty Valves for HVAC 06/18
6 Hangers and Supports for HVAC Piping and Equipment 06/ Vibration and Seismic Controls for HVAC Piping And Equipment 06/ Identification for HVAC Piping and Equipment 06/ Testing, Adjusting, and Balancing for HVAC 06/ Duct Insulation 06/ HVAC Equipment Insulation 06/ HVAC Piping Insulation 06/ Instrumentation and Controls for HVAC 06/ Sequence of Operations for HVAC Controls 06/ Facility Fuel Oil Piping RESERVED Facility Natural Gas Piping 06/ Hydronic Piping 06/ Ground Loop Heat Pump Piping RESERVED Hydronic Pumps 06/ Steam and Condensate Heating Piping 06/ Steam Condensate Pumps RESERVED Refrigerant Piping RESERVED HVAC Water Treatment 06/ HVAC Ducts and Casings RESERVED Metal Ducts 06/ Fibrous-Glass Ducts RESERVED Thermoset Fiberglass-Reinforced Plastic Ducts RESERVED Air Duct Accessories RESERVED Flexible Ducts RESERVED HVAC Fans RESERVED Axial HVAC Fans RESREVED Centrifugal HVAC Fans 06/ HVAC Power Ventilators RESERVED Air Curtains RESERVED Air Terminal Units 06/ Diffusers, Registers, and Grilles RESERVED HVAC Gravity Ventilators RESERVED Commercial Kitchen Hoods RESERVED
7 Particulate Air Filters 06/ Chimneys, Breechings, and Stacks 06/ Draft Control Devices - RESERVED Heating Boilers 06/ Electric Boilers 06/ Condensing Boilers 06/ Cast Iron Boilers 06/ Water-Tube Boilers RESERVED Finned Water-Tube Boilers 06/ Fire-Tube Boilers 06/ Heating Boiler Feedwater Equipment 06/ Deaerators RESERVED Furnaces RESERVED Fuel-Fired Heaters 06/ Fuel-Fired Duct Heaters RESERVED Gas-Fired Radiant Heaters RESERVED Fuel-Fired Unit Heaters RESERVED Heat Exchangers for HVAC 06/ Packaged Compressor and Condenser Units 06/ Packaged Air-Cooled Refrigerant Compressor and Condenser Units 06/ Evaporative Refrigerant Condensers RESERVED Packaged Water Chillers RESERVED Direct-Fired Absorption Water Chillers RESERVED Indirect-Fired Absorption Water Chillers RESERVED Centrifugal Water Chillers 06/ Reciprocating Water Chillers 06/ Scroll Water Chillers RESERVED Rotary-Screw Chillers RESERVED Open-Circuit, Forced Draft Cooling Towers 06/ Closed-Circuit, Forced Draft Cooling Towers RESERVED Air-to-Air Energy Recovery Equipment RESERVED Indoor Central-Station Air Handling Units RESERVED Modular Indoor Central-Station Air Handling Units 06/ Indoor, Indirect Fuel-Fired Heating and
8 Ventilating Units RESERVED Indoor, Direct Gas-Fired Heating and Ventilating Units RESERVED Decentralized Unitary HVAC Equipment 06/ Packaged Terminal Air Conditioners 06/ Computer Room Air Conditioners RESERVED Split-System Air Conditioners RESERVED Water-Source Unitary Heat Pumps 06/ Air Coils 06/ Fan-Coil Units 06/ Unit Ventilators RESERVED Radiators 06/ Cabinet Unit Heaters RESERVED Propeller Unit Heaters RESERVED Radiant Heating Units RESERVED Radiant Heating Electric Cables RESERVED Radiant Heating Electric Panels RESERVED Humidifiers 06/ Dehumidifiers RESERVED DIVISION 26 ELECTRICAL General 06/ Maintenance Testing of Electrical Systems 06/ Medium-Voltage Cables 06/ Low Voltage Electric Power Conductors and Cables 06/ Undercarpet Electrical Power Cables - RESERVED Grounding and Bonding for Electrical Systems 06/ Hangers and Supports for Electrical Systems RESERVED Raceway and Boxes for Electrical Systems 06/ Cable Trays for Electrical Systems RESERVED Underfloor Raceways for Electrical Systems RESERVED Vibration and Seismic Controls of Electrical Systems RESERVED Identification for Electrical Systems RESERVED
9 Overcurrent Protective Device Coordination Study 06/ Electrical Power Monitoring - RESERVED Lighting Control Devices 06/ Unit Substations 06/ Medium-Voltage Transformers RESERVED Substation Transformers 06/ Pad-Mounted, Liquid Filled Transformwers 06/ Dry-Type Transformers (600 V and Less) 06/ Panelboards 06/ Motor Control Centers 06/ Electricity Metering 06/ Wiring Devices 06/ Variable-Frequency Motor Controllers - RESERVED Packaged Engine Generators 06/ Central Battery Inverters RESERVED Static Uninterruptible Power Supply RESERVED Power Factor Correction Equipment RESERVED Facility Lightning Protection 06/ Interior Lighting 06/ Exterior Lighting 06/18 DIVISION 27 COMMUNICATIONS Voice and Data Communications Systems 06/18 DIVISION 31 EARTHWORK Maintenance of Earthwork 10/ Soils for Earthwork 10/ Aggregates for Earthwork 10/ Geosynthetics for Earthwork 10/ Schedules for Earthwork 10/ Schedules for Clearing RESERVED Schedules for Earth Moving RESERVED Commissioning of Earthwork 10/ Geotechnical Instrumentation and Monitoring of Earthwork 10/ Clearing and Grubbing 10/ Selective Clearing RESERVED
10 Selective Tree and Shrub Removal, Trimming and Replacement 10/ Earth Stripping and Stockpiling 10/ Off-Gassing Mitigation RESERVED Grading 10/ Rough Grading RESERVED Fine Grading RESERVED Roadway Subgrade Reshaping RESERVED Finish Grading RESERVED Spreading and Grading Topsoil RESERVED Excavation and Fill 10/ Embankments RESERVED Erosion and Sedimentation Controls 10/ New Jersey Department of Environmental Protection (NJDEP) Phase II Stormwater Management Regulations 10/ New Jersey Pollution Discharge Elimination System (NJPDES) General permit No. NJG Stormwater Discharge Associated with Construction And Mining Activity 10/ Environmental Permitting (Other) 10/ Stormwater Drainage Systems 10/ Earthwork Methods 10/ Shoring and Underpinning 10/ Excavation Support and Protection 10/15 DIVISION 32 EXTERIOR IMPROVEMENTS Operation and Maintenance of Exterior Improvements 1/ Operation and Maintenance of Irrigation RESERVED Common Work Results for Exterior Improvements 1/ Schedules for Exterior Improvements 1/ Bases, Ballasts, and Paving 1/ Base Courses RESERVED Flexible Paving RESERVED Rigid Paving RESERVED Unit Paving 1/ Aggregate Surfacing RESERVED
11 Curbs, Gutters, Sidewalks, and Driveways 1/ Paving Specialties RESERVED Athletic and Recreational Surfacing RESERVED Fences and Gates 1/ Retaining Walls 1/ Site Furnishings 1/ Manufactured Metal Bollards 1/ Constructed Wetlands 1/ Irrigation 1/ Planting Preparation 1/ Turf and Grasses 1/ Seeding 1/ Plants 1/ Planting Accessories RESERVED Exterior Planting Support Structures RESERVED Transplanting RESERVED DIVISION 33 UTILITIES Common Work Results for Utilities RESERVED Water Utility Distribution Piping 6/ Water Supply Wells RESERVED Sanitary Sewerage Utilities 6/ Packaged Utility Lift Stations 6/ Utility Septic Tank Systems RESERVED Storm Drainage Utilities 6/ Subdrainage RESERVED Pond and Reservoir Liners RESERVED Natural-Gas Distribution RESERVED Liquid Fuel Distribution RESERVED Fuel-Oil Distribution 6/ Hydronic Energy Distribution 6/ Steam Energy Distribution RESERVED Electrical Underground Ducts and Manholes 6/18
12
DOCUMENT TABLE OF CONTENTS
DOCUMENT 00003 June 16, 2005 TABLE OF CONTENTS DOCUMENT NO. INTRODUCTORY INFORMATION DOCUMENT 00003 TABLE OF CONTENTS DIVISION 1 GENERAL REQUIREMENTS SECTION 01011 SECTION 01025 SSP21.1-1 SECTION 01026
More informationSpringpoint Architects, pc SECTION Childcare Center Architect s Project No TABLE OF CONTENTS Monroe County Comm. Sch. Corp.
Volume 1 Bidding Requirements, Contract Forms, Conditions of the Contract, Division 1, Architectural and Site Specifications 000107 Certification Page 000110 Table of Contents DIV00 PROCUREMENT AND CONTRACTING
More informationSITE SYSTEMS: FANNIE MAE EXPECTED USEFUL LIFE TABLES (FMEUL)
SITE SYSTEMS: FANNIE MAE EXPECTED USEFUL LIFE TABLES (FMEUL) Basketball Courts 15 25 Built Improvements Playgrounds, Site Furniture, etc. 20 20 Catch Basin 40 40 Cold Water Lines 40 40 Compactors DHW Supply
More informationAppendix 13. Categories of Cooling and Heating systems
EcoShopping - Energy efficient & Cost competitive retrofitting solutions for Shopping buildings Co-funded by the European Commission within the 7 th Framework Programme. Grant Agreement no: 609180. 2013-09-01
More informationFACILITY STANDARDS (FS) 2 TABLE OF CONTENTS
FACILITY STANDARDS (FS) 2 TABLE OF CONTENTS FS 2 Orientation and Navigation Volume I- Introduction and Principles A. Overview 1. Guideline Compliance 2. Process B. Economic Impact Program 1. Economic Impact
More informationTABLE OF CONTENTS Mechanical Library
DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS 000101 Project Title Page Project Manual title page. 000107 Seals Page For seals of design professionals on Project Manual. 000115 List of Drawing
More informationTABLE OF CONTENTS Mechanical Library
DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS 000101 Project Title Page 03/17 Project Manual title page. 000107 Seals Page 02/12 For seals of design professionals on Project Manual. 000115 List
More informationCITY & COUNTY OF DENVER COMMUNITY PLANNING & DEVELOPMENT BUILDING PERMIT POLICY
Number: ADMIN 120A Issued Date: March 21, 2016 Page: 1 of 10 Reference: ADMIN Section 120 LICENSES AND REGISTRATIONS General. There shall be various classes of licenses and an electrical registration,
More informationSCHEDULE OF FEES. Penalty Fees. Building Fee Schedule FEE
SCHEDULE OF S Penalty Fees. The fee for construction work performed before securing permit(s), where required, may be charged a fee of TWO TIMES THE COST OF THE PERMIT (S). Building Fee Schedule Residential
More information21. Plumbing fixture mixing valves, PRV, electronic faucets and flush valve(excluding batteries)optional Cost proposal to include these device
DIVISION 23800 APPENDIX A ASHTABULA CAMPUS: 1. Air Handling Equipment And Appurtenances 2. Exhaust Fans 3. Fume Hood Exhaust Fans 4. Fume Hood monitoring devices and annual certification of face velocity
More informationMUKWONAGO AREA SCHOOL DISTRICT CAPITAL IMPROVEMENT / MAINTENANCE STUDY
ARCHITECTURE ROLLING HILLS ELEMENTARY SCHOOL Rolling Hills Elementary was built in 1999 and is the newest addition to the Mukwonago Area School District. The building contains approximately 64,900 gross
More informationINDEX OF VA STANDARD DETAILS AS OF DECEMBER 2014
DIVISION 00 SD000115-01 SD000115-02 SD000115-03 SD000115-04 SD000115-05 SD000115-06 SD000115-07 SD000115-08 SD000115-09 SD000115-10 SD000115-11 SD000115-12 SD000115-13 SD000115-14 SD000115-15 SD000115-16
More informationA/E REVIEW CHECKLIST SITE & LANDSCAPE
A/E REVIEW CHECKLIST SITE & LANDSCAPE Reviewers should - Use Checklists when reviewing any type of VA construction project for the following disciplines: Architectural, Boiler Safety Devices Operation
More informationThe latest cost data for reliable plumbing estimates. Cost data from the most trusted source in North America
The latest cost data for reliable plumbing estimates Cost data from the most trusted source in North America 38th annual edition Melville J. Mossman, PE, Senior Editor Engineering Director Bob Mewis, CCC
More informationSchedule of Fees Schedule B
Schedule of Fees Schedule B BUILDING DEPARTMENT 2. Building Permit* $65.00 for value or valuation up to $1,000. After $1,000 of value $8.00 per $1,000. After $1,000,000 of value $6 per $1,000 3. Demolition
More informationEnergy-Efficiency Measures List
Guidelines for Public Agencies Energy-Efficiency Measures List 1.0 Envelope 1.1 Reduce Heat Losses-Ceiling/roof 1.11 Additional Ceiling/Roof Insulation 1.12 Exhaust Attics 1.13 Use Light-Colored Roof Surfaces
More informationDOMESTIC WATER PACKAGED BOOSTER PUMPS
DIVISION 22 PLUMBING 22 11 16 DOMESTIC WATER PIPING 22 11 19 DOMESTIC WATER PIPING SPECIALTIES 1. To facilitate landscape and other maintenance operations, exterior hose bibs shall be provided at 150 foot
More informationDESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES
2.05 PLUMBING GENERAL DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES - 2.05 It is expected that the plumbing design professional will conform to accepted good engineering design practices.
More informationMH Non-Residential Permit Fees All Commercial Permit fees require a 3% BBS State Tax and are subject to a plan review and base fee.
BUILDING New Building $.45 per sq ft $3,500 Min $.40 per sq ft $1,000 Min $.20 per sq ft $250 Min Demolition $.10 per sq ft $150 Min Accessory Structure (over 200 sq ft) $.40 per sq ft $750 Min Retaining
More informationOperating Performance
INFORMATION SHEET 1 Jackson Engineering Advisers are specialist Building Services Engineers. This information sheet is offered as an aid to Building Owners and Managers as a guide to plant life expectancies.
More informationTighe&Bond. Groton Heights School Mechanical Evaluation. 1 Existing Conditions. 1.1 Water Service Entrance
Groton Heights School Mechanical Evaluation TO: FROM: Amy Vaillancourt, Project Manager Harley Langford, Project Manger Jason Curtis, P.E. DATE: February 24, 2016; Revised May 31, 2016 On Monday, December
More informationEstimated Repair, Replacement, and Upgrade Costs
Description Electrical Attic ventilator-mechanical $250 Baseboard heater (4') $150-$400 Ceiling fan $200 Doorbell system $80-$100 Dryer duct $100-$150 Hardwired smoke detector $60-$120 Exhaust Fan-Bathroom
More informationA. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.
Page 238126-1 SECTION 238126 - This Section includes requirements for the LEED Rating System. However, equipment specified in this Section may not qualify for LEED Rating System prerequisites and credits.
More informationResidential Construction and Remodeling Estimates. compliments of. pillartopost.com
Residential Construction and Remodeling Estimates compliments of STRUCTURE/EXTERIOR Structure > addition (foundation to roof) $95 $130/sq.ft. > basement entrance $5250 $10500 > basement main beam $2100
More informationPLAN REVIEW SUBMITTAL GUIDE
PLAN REVIEW SUBMITTAL GUIDE Plans, specifications and other construction documentation for the initial plan review should be as complete as possible at the time of submittal. Use this convenient guide
More informationTABLE OF CONTENTS. Part I Administrative... 1
Part I Administrative............................ 1 CHAPTER 1 ADMINISTRATION............... 1 R101 Title, Scope and Purpose.................... 1 R102 Applicability.............................. 1 R103
More informationKINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION
SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to
More informationService Description Service Shop Customer Charge Comments. Electronic Shop. Electric Shop Yes additional circuits for equipment
Fire alarm repairs Electronic Shop Fire alarm sound level testing Electronic Shop Fire system inspections Electronic Shop Installation of additional fire detection/alarm/supression devices Electronic Shop
More information$ Each additional variance per petition. $ All Other Zoning Districts: One variance per petition
2015 SCHEDULE COMMUNITY DEVELOPMENT DEPT. ENGINEERING PLAN REVIEW Single Family New Construction All Other Plan Reviews Minimum Engineering Fee Planned Unit Development - PUD: Step #1: Step #2: See Site
More informationCONSTRUCTION DOCUMENTS CHECKLIST
CONSTRUCTION DOCUMENTS CHECKLIST To be completed by the Designer and reviewed for accuracy by the UNC Planning Manager. for PROJECT: PREPARED BY: date: (name of Designer) phone no. (name of Design firm)
More informationAHRI Certification Program Scopes - COOLING
Air-to-Air Energy Recovery Ventilators (AHRI Std. 1060) Automatic Commercial Ice-Cube Machines and Ice Storage Bins (AHRI Stds. 810 & 820) Central Station Air-Handling Units (AHRI Std. 430) Commercial
More informationC. Samples for Initial Selection: For units with factory-applied color finishes.
SECTION 238126- SPLIT-SYSTEM AIR-CONDITIONERS PART 1- GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More information2013 ASHRAE. Standards & Guidelines CD. Contents
2013 ASHRAE Standards & Guidelines CD Contents ANSI/ARI/ASHRAE ISO Standard 13256-1:1998 (RA 2012) Water-source heat pumps testing and rating for performance Part 1: Water-to-air and brine-to-air heat
More informationREQUIRED CONTRACT DETAIL. $2, , Direct DC Fuel Cell Power System, Stationary PACE Power output < 40 kw
Residential Eligible Improvements and Guidelines FLORIDA To qualify for Ygrene funding, all project improvements must meet or exceed applicable local, state and federal codes and standards, and be installed
More informationRSES SERVICE APPLICATION MANUAL TABLE OF CONTENTS AUGUST 2016
This Table of Contents lists the complete contents of the RSES s (SAM) issued to date. Section 1 Refrigeration 620-05 Principles of Refrigeration Part 1 620-06 Principles of Refrigeration Part 2 620-67
More informationExisting Conditions Assessment November 14, 2006 NORTH MIDDLESEX REGIONAL HIGH SCHOOL Townsend, MA L21366/ /Page 1
L21366/101 090 00.00/Page 1 HVAC EXECUTIVE SUMMARY The North Middlesex Regional High School has received average maintenance of the HVAC systems over its occupied years. Even with adequate maintenance,
More informationCook - Wissahickon Elementary School
Cook - Wissahickon Elementary School 201 E. Salaignac St., Philadelphia, PA 19128 HVAC Replacement Project Scope Determination Report May 10, 2018 Prepared by: G.P. Lamina, Jr., P.E., MBA School District
More informationAugust 15, 2013 Page 1 of 19
Section C401 Application Compliance with C402, C403, C404 and C405 AND (either C406.2, C406.3 or C406.4) Compliance with C402, C403, C404 or C405 Section C402 Building Envelope (Climate Zone 5A) Space-Conditioning
More informationMUKWONAGO SCHOOL DISTRICT CAPITAL IMPROVEMENT / MAINTENANCE STUDY
MUKWONAGO SCHOOL DISTRICT ARCHITECTURE PARK VIEW MIDDLE SCHOOL The original school building was dedicated in 1954 as the High School, with an addition in 1959, a library addition in 1970, and an addition/renovation
More informationEdward Jenner Elementary Academy of the Arts
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationRecent Updates as of July 7, 2016
University of New Hampshire University of New Hampshire Scholars' Repository Recent Changes Facilities 7-7-2016 Recent Updates as of July 7, 2016 Sandra Hickey sandra.hickey@unh.edu Follow this and additional
More informationAIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University
AIR-CONDITIONING SYSTEMS AND APPLICATIONS Abdullah Nuhait Ph D. King Saud University AIR-CONDITIONING SYSTEMS Earliest air conditioning system used only for heating (winter) Provided heated air for comfort
More informationSECTION/SUBSECTION (scroll down to view more listings; this list is arranged alphabetically) SCOPE. AHRI Section-Subsection Scopes
Air Control and Distribution Devices Product Section Ducted devices, used to deliver air into/or remove air from a space and which provide control of air volume, direction, temperature, and/or pressure.
More informationTopic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline
ME 414/514 HVAC Systems Overview Equipment Outline 2-1 The Complete System 2-2 The Air-Conditioning and Distribution System 2-3 Mechanical Equipment Air-handling Equipment Heating Equipment Boilers Furnaces
More informationMechanical Costs with RSMeans data Mechanical Costs with RSMeans data. Mechanical Costs. with RSMeans data. 42nd annual edition
A comprehensive collection of costs designed for everything from detailing large scopes of work to conceptually estimating smaller ones. With adjustments for more than 970 locations across North America,
More informationAHRI Product Section and Subsection Scopes
Air Control and Distribution Devices Product Section Air-Cooled and Evaporative Condensers Subsection Air-Cooling and Air Heating Coils Subsection Air-to-Air Energy Recovery Ventilation Product Section
More informationGenevieve Melody Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationCanadian Property Inspections
Cover Page Canadian Property Inspections Home Inspection Report L9Z-1K4 Inspection prepared for: K.C. Pitman Date of Inspection: 3/6/2017 Time: 3pm Age of Home: 42 Size: 500-1000 Weather: Cloudy, cool.
More informationTABLE OF CONTENTS. Part I Administrative
Part I Administrative.......................... 1-1 CHAPTER 1 SCOPE AND ADMINISTRATION. 1-1 R101 General............................. 1-1 R102 Applicability......................... 1-2 R103 (Not adopted)........................
More informationNYC Department of Education
Asset: P.S. 841- QUEENS, 48-25 37TH STREET, New York, 11104 Inspection Id Inspection Type Time In Last Edited ME : Mechanical 2018-04-02 12:54 PM 2018-05-14 12:28 PM Asset Data Are there fuel tanks? Total
More informationGARCIA GALUSKA DESOUSA Consulting Engineers
L#56566/Page 1/May 23, 2017 HVAC Heating Plant The original Town Hall building and Addition building are primarily heated by a gas fired hot water plant that is located in the basement. The boiler plant
More informationElement Z General Design Requirements Existing Facilities Information
Charles M. LeMaistre PART 1 - INTRODUCTION 1.01 OVERVIEW A. This Section provides general information for building systems and components. B. Refer to the Owner s Design Guideline Elements A though G and
More informationCONTENTS. B. System Design and Performance Requirements
15625 Water Chillers This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes
More informationREPAIR ESTIMATE GUIDE
REPAIR ESTIMATE GUIDE STRUCTURE Foundation Addition (foundation to roof)... $125 - $170/sq.ft. Basement entrance... $6485 - $13690 Basement main beam... $2740 Basement support post/foundation... $650 -
More informationInspecta-Homes 2469 University Avenue West St. Paul MN Ph#: (651)
Page 1 Doc #: Inspector: Date: Dwelling Address: Client Name: Client's Agent: Real Estate Company: Please refer to the General Home Inspection Contract. Thank you for using Minnesota and Western Wisconsin's
More informationJohn Palmer Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationLetter of Credit Itemized Cost Estimate For: 100% Site Development Costs
Letter of Credit Itemized Cost Estimate For: 100% Site Development Costs The following form is to be filled out by the Project Consultant(s) and submitted to the City of Kitchener, Planning Division for
More informationNYC Department of Education
Asset: P.S. 86 ANNEX - BRONX, 124 EAMES PLACE, New York, 10468 Inspection Id Inspection Type Time In Last Edited ME : Mechanical 2018-04-05 1:03 PM 2018-04-27 1:35 PM Asset Data Are there fuel tanks? Total
More informationVOTER BOND REFERENDUM 2018 SUMMARY OF WORK PROPOSED
Ashton Elementary School 1 Masonry Repair $ 42,781.50 2 Replace HVAC $ 375,000.00 3 Replace SAT @ Various Locations $ 92,364.00 3 Recoat & Resurface Exterior Paved Play Area $ 135,978.30 3 Various Technological
More informationTop of the World Tower
Workplace Building Preventive Maintenance Checklist conducted for Top of the World Tower Conducted on 22 Oct 2018 11:00 AM Prepared by Greg Langley Location 1247 Dartmouth St, Albany, CA 94706, USA Completed
More informationUNIFORM MECHANICAL CODE
INDEX Note: Content and section numbers will be updated before publishing. 2009 International Association of Plumbing and Mechanical Officials. All rights reserved. The copyright in this index is separate
More informationAxiom Property Inspections
Cover Page Axiom Property Inspections Property Inspection Report 868 Wally Avenue, Henderson NV, 89178 Inspection prepared for: John Doe Agent: David Lawson - Axiom Inspection Date: 8/12/2010 Time: 2:30
More informationSECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS
SECTION 237413 - PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, outdoor, central-station air-handling units (rooftop units) with the
More informationRead Only Document Not For Distribution
Chapter 9 Indirect Waste Piping and Special Wastes 9.1 INDIRECT WASTES 9.1.1 General Drains from fixtures, fixture compartments, equipment, appliances, appurtenances, and other devices requiring protection
More informationSECTION SPLIT-SYSTEM AIR-CONDITIONERS
SECTION 238126 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to
More informationRoutine Maintenance Schedule and Checklist
Landscaping and Grounds Routine Maintenance Building Exterior Routine Maintenance Schedule and Checklist Walk property-pick up trash Daily Staff Weekly / Mow lawn (Mulching lawnmower); edge if needed Seasonal
More informationUrban Conservation Practice Physical Effects ESTABLISHMENT, GROWTH, AND HARVEST NUTRIENT MANAGEMENT
NOT WELL 800 - Urban Stormwater Wetlands A constructed system of shallow pools that create growing conditions for wetland plants to lessen the impacts of stormwater quality and quantity in urban areas.
More informationThe Ultimate Home Maintenance Schedule
The Ultimate Home Maintenance Schedule On-Going Quarterly Maintenance Schedule Check interior and exterior faucets for leaks. Clean aerators. Replace washers if Clean with baking soda. Pour water down
More informationJoseph Brennemann Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationFacilities Management Services
Facilities Management Services Operating Budget Facilities Management (FM) receives an Operating Budget each year predicated on funding the routine, predictable costs of cleaning, maintaining,, and repairing,
More informationFrancis M McKay Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationSECTION HEATING TERMINAL UNITS
SECTION 15830 HEATING TERMINAL UNITS PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Baseboard or Fin-Tube Radiation. 2. Convectors. 3. Cabinet Unit Heaters. 4. Unit Heaters - Hot Water. 5. Hydronic
More informationSECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS
SECTION 22 34 00 (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS System shall provide a complete hot water return throughout the entire system with balancing (flow control) valves not less than 10 feet from
More informationCMHC HOME MAINTENANCE CHECKLIST
Make sure air vents indoors and outdoors (intake, exhaust and forced air) are not blocked by snow or debris. Check and clean range hood filters on a monthly basis. Test ground fault circuit interrupter(s)
More informationNYC Department of Education
Asset: P.S. 69 - STATEN ISLAND, 144 KEATING PLACE, New York, 10314 Inspection Id Inspection Type Time In Last Edited ME : Mechanical 2018-01-19 8:39 AM 2018-01-23 4:33 PM Asset Data Are there fuel tanks?
More informationCOMMERCIAL PERMIT APPLICATION AND CHECKLIST. Depending on the scope of your project, the following submittal requirements will apply:
Planning/Building Department 115 Ramsdell Street Fircrest WA 98466 (253) 564-8902 COMMERCIAL PERMIT APPLICATION AND CHECKLIST Depending on the scope of your project, the following submittal requirements
More informationATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL
LINE ITEM # ATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL LINE ITEM DETAIL Labor Material FURNACE COMPONENTS 1 Furnish & Install Sight-Impaired Thermostat For Heating and Cooling
More informationCharter Township of Flushing Construction Permit Fee Schedule.Construction and Development Services Department
Charter Township of Flushing Construction Permit Fee Schedule.Construction and Development Services Department 1. CONSTRUCTION PERMIT FEES: A. General: Fee basis/value of construction shall be determined
More informationVapor-Compression Refrigeration
Vapor-Compression Refrigeration condenser D C expansion device compressor A B evaporator Types of Heat Pumps water-source heat pumps water-to-water heat pump air-source heat pumps Cooling Heating
More informationConstruction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA
Construction Standards Page 233423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified
More informationNYC Department of Education
Asset: P.S. 111 - MANHATTAN, 440 WEST 53 STREET, New York, 10019 Inspection Id Inspection Type Time In Last Edited ME : Mechanical 2018-03-16 8:47 AM 2018-03-21 8:02 AM Asset Data Are there fuel tanks?
More informationFacilities Management State-Funded and Billable Services
Facilities Management State-Funded and Billable Services Facilities Management receives funding to provide maintenance in eligible state-supported areas only, per UCOP guidelines. State-supported areas,
More informationSECTION SPLIT-SYSTEM AIR-CONDITIONERS
SECTION 23 81 26 SPLIT-SYSTEM AIR-CONDITIONERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.
More information2009 IPC ,IMC Q &A ANDIFGC
2009 IPC,IMC ANDIFGC Q &A TABLE OF CONTENTS PREFACE.... ix ABOUT THE INTERNATIONAL CODE COUNCIL...x IPC CHAPTER 1 SCOPE AND ADMINISTRATION...1 Section 101 General... 1 Section 102 Applicability... 1 Section
More informationNYC Department of Education
Asset: P.S. 199 ANNEX (@ ST. TERESA'S) - QUEENS, 50-15 44TH STREET, New York, 11377 Inspection Id Inspection Type Time In Last Edited ME : Mechanical 2018-04-18 11:39 AM 2018-05-14 12:27 PM Asset Data
More informationMEP Syllabus CAREER DEVELOPMENT CENTRE SHRISTI MEP. Trichy-26
SHRISTI MEP CAREER DEVELOPMENT CENTRE Trichy-26 MEP Syllabus Contact : dhinesh.shristimep@gmail.com / sangeetha.shristimep@gmail.com +91-80984 49847, 97158 67493 ELECTRICAL DESIGNING AND DRAUGHTING FUNDAMENTALS
More information1354 CHECKLIST for Project Closeout
1354 CHECKLIST for Project Closeout PROJECT NUMBER: BUILDING NUMBER: DESCRIPTION OF PROJECT: Describe description of work; i.e., New Construction, Addition, Modification, Renovation, etc DRAWING NUMBER
More informationNYC Department of Education
Asset: ACHIEVEMENT FIRST ENDEAVOR CHARTER SCHOOL- BROOKLYN, 510 WAVERLY AVENUE, New York, 11238 Inspection Id Inspection Type Time In Last Edited ME : Mechanical 2018-03-14 8:42 AM 2018-03-23 10:17 AM
More informationNYC Department of Education
Asset: LIBERTY HS - MANHATTAN, 250 WEST 18 STREET, New York, 10011 Inspection Id Inspection Type Time In Last Edited ME : Mechanical 2018-01-29 11:32 AM 2018-02-01 10:16 AM Asset Data Are there fuel tanks?
More informationSECTION CONVECTION HEATING AND COOLING UNITS
PART 1 GENERAL 1.01 SECTION INCLUDES A. Baseboard radiation. B. Finned tube radiation. C. Convectors. D. Unit heaters. E. Cabinet unit heaters. F. Fan-coil units. G. Unit ventilators. H. Blower-coil units.
More informationElement Z General Design Requirements Existing Facilities Information
PART 1 - INTRODUCTION 1.01 OVERVIEW A. This Section provides general information for building systems and components. B. Refer to the Owner s Design Guideline Elements A though G and Element Z for technical
More informationJosefa Ortiz De Dominguez Elementary School
Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual
More informationTechnical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer
Technical Development Program PRESENTED BY: COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems Ray Chow Sales Engineer TDP Updates Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section
More informationCIVIC CONDOMINIUM PREVENTIVE MAINTENANCE SCHEDULE
Index No. Category/Component DescripCon Doors & Windows DW- 1 Door Hardware & Closers X DW- 2 Exterior Metal Doors X DW- 3 Garage & Loading Ramp Doors DW- 4 Interior Wood & Metal Doors X DW- 5 Storefront
More informationA. Install all temporary erosion control measures (in accordance with MNDOT General Conditions 2573) prior to site disturbance.
The language provided in these specifications is meant to serve as a reminder and provide a generic example of the type of language that should be provided in final construction documents. This language
More informationNYC Department of Education
Asset: P.S. 146 - BRONX, 968 CAULDWELL AVENUE, New York, 10456 Inspection Id Inspection Type Time In Last Edited ME : Mechanical 2017-12-01 8:57 AM 2018-05-31 2:59 PM Asset Data Are there fuel tanks? Total
More informationSummary Comparison of Simulation Program Features
Summary Comparison of Simulation Program Features FEATURE DOE2.2 equest TRACE 700 HAP Public/Proprietary Public Domain Proprietary Proprietary Proprietary Simulation Method 8760 hours 8760 hours 8760 hours
More informationNYC Department of Education
Asset: P.S./I.S. 194 - BRONX, 2365 WATERBURY AVENUE, New York, 10462 Inspection Id Inspection Type Time In Last Edited ME : Mechanical 2018-01-24 8:34 AM 2018-02-01 10:02 AM Asset Data Are there fuel tanks?
More informationMECHANICAL SERVICES 101. Ian White
MECHANICAL SERVICES 101 Ian White Contents 1. Ventilation 2. Heat Gains & Losses 3. Heating Ventilation Air Conditioning (HVAC) Systems What are Building Services Building Services incorporate all aspects
More informationAFFORDABLE CANADIAN HOME INSPECTIONS
AFFORDABLE CANADIAN HOME INSPECTIONS Al Wright Hamilton, Ontario Cell: 905-730-9300 Expectancy of Household Components Appliances Compactors 7-12 Dishwashers 9-16 Disposal, Food Waste 11-16 Dryers 11-16
More information