1 Brivis Inverter Multi-Head Split System R40A INSTALLATION MANUAL PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLING & USING THIS PRODUCT

2 CONTENTS SAFETY PRECAUTIONS Warning...2 Caution...2 SPECIFICATIONS Technical data...3 INSTALLATION INSTRUCTIONS Hi-Wall indoor unit...4 Selecting installation position...4 Ducted indoor unit...9 Outdoor unit installation...4 REFRIGERANT PIPE CONNECTION Refrigerant pipe connection...5 ELECTRICAL INSTALLATION Electrical installation...6 REFRIGERATION Air purging with vacuum pump...9 Electrical safety and leak test...2 COMMISSIONING AND TEST RUN Commissioning...22 Please read this manual carefully and retain for future reference Inside you will find many helpful hints on how to install, test and operate the Brivis system properly. All illustrations and specifications in this manual are subject to change without notice. CAUTION Installation must be carried out by suitably authorised and qualified personnel. This appliance must be installed in accordance with all local and national wiring regulations. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Young children should be supervised to ensure that they do not play with the system. Do not install this system in a wet room such as a bathroom or laundry. Model Numbers Outdoor Hi-Wall Indoor Slim Ducted Indoor MON2H053 MINHW020 MINSD020 MON3H076 MINHW026 MINSD026 MON4H078 MINHW035 MINSD035 MON5H05 MINHW052 MINSD052 MON5H36 MINHW070 MINSD kW Outdoor Unit available late 204

3 SAFETY PRECAUTIONS Please read the follow SAFETY PRECAUTIONS carefully before installation. Electrical work must be installed by a licensed electrician. Be sure to use the correct wiring ratings for power and communications wiring. Incorrect or incomplete installation or failure to adhere to these instructions may cause harm or damage. The seriousness is classified by the following indications. WARNING CAUTION This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to property. The items to be followed are classified by the symbols: Symbol denotes item that is PROHIBITED. WARNING ) Only qualified personnel shall undertake the installation. If the installation is defective, it may cause water or refrigerant leaks, electrical shock or fire. 2) Install strictly in accordance with these installation instructions. If installation is defective, it may cause water or refrigerant leaks, electrical shock or fire. 3) Use the appropriate accessories/parts and specified items for installation. Otherwise, the equipment may fall, leak refrigerant or water, or cause electrical shock or fire., 4) Install the equipment in a strong, firm location, able to withstand the unit s operating weight. If the installation location is insufficient or the installation is incomplete, the equipment may fall and cause injury. 5) For electrical work, follow all local and national wiring standards and regulations, and in accordance with the installation instructions. An independent circuit must be used. If the electrical circuit capacity is insufficient or defective, it may cause electrical shock or fire. 6) Use the specified cables sizes and connect tightly. Clamp the cable so that no external force can be acted on the terminals. If the connection or fixing is inadequate, the connections may overheat and cause fire. 7) Wiring routing must be properly arranged so that control board cover is fixed properly. If the control board is not properly fixed, it may cause the connections to overheat and cause fire or electrical shock. 8) When carrying out piping connection, take care not to let air or other contaminants enter the refrigeration system. Use only clean, specified refrigerant, otherwise the system will operate at a lower capacity/efficiency, or at abnormally high pressures causing risk of explosion or injury. 9) Do not modify the length of any power supply cords or use extension cords. Do not share the power supply with other electrical appliances. Otherwise, it may cause fire or electrical shock. CAUTION ) This equipment must be suitably earthed and installed with an appropriate circuit breaker. Electrical shock may occur if the grounding is inadequate. 2) Do not install the unit in an area where leakage of flammable gases may occur. If the refrigerant leaks and is allowed to accumulate around the unit, it may cause fire. 3) Install the condensate drain piping as per the installation instructions. If the drainage is inadequate or incomplete, it may leak into the space and cause damage. 4) The appliance shall be installed in accordance with all local and national wiring regulations. 5) Do not install or operate this system in a wet room such as a bathroom or laundry. 2

4 SPECIFICATIONS Maximum Number of Indoor Units MON2H053 MON3H076 MON4H078 MON5H05 MON5H36 Qty Power Supply V-Ph-Hz 220~ Cooling Heating Compressor Maximum Input Current Sound Power Level Sound m Dimensions Refrigerant Refrigerant Piping OUTDOOR UNIT Rated Capacity (Maximum) kw 5.3 (6.77) 7.6 (0.8) 7.7 (0.96) 0.4 (2.68) 3.6 (5.2) Power Input Running Current A AEER W/W Star Rating Rated Capacity (Maximum) kw 5.8 (6.86) 8. (0.8) 8.4 (.03).6 (3.48) 4.5 (5.54) Power Input Running Current A ACOP W/W Star Rating Type Twin-rotary Twin-rotary Twin-rotary Twin-rotary Twin-rotary A Net (W x D x H) mm 845 x 320 x x 35 x x 35 x x 345 x x 392 x 369 Gross (W x D x H) mm 965 x 395 x x 395 x x 395 x x 435 x x 495 x 505 Net / Gross Weight kg 48 / / / / / 2 Type Connection Size: Liquid Line 2x Ø6.35 3x Ø6.35 4x Ø6.35 5x Ø6.35 5x Ø6.35 mm 2x Ø9.52 3x Ø9.52 4x Ø9.52 4x Ø9.52 Connection Size: Gas 2x Ø9.52 x Ø2.7 x Ø2.7 x Ø2.7 x Ø2.7 Maximum Total System Pipe Length Pre-Charged Length Maximum Length Per Indoor Unit Maximum Vertical Separation Outdoor Unit ABOVE Indoor Unit Maximum Vertical Separation Outdoor Unit BELOW Indoor Unit Maximum Height Difference Between Indoor Units Ambient Cooling Operating Range Heating INDOOR UNIT - HIWALL Power supply Cooling Heating Airflow (Hi / Med / Lo) Sound Pressure (Hi / Med / Dimensions Control V-Ph-Hz MINHW020 MINHW026 MINHW035 MINHW052 MINHW070 Rated Capacity (Range) kw 2.0 (.7 ~ 3.7) 2.6 (.90 ~ 4.04) 3.5 (2.2 ~ 4.7) 5.2 (3.03 ~ 6.46) 7.0 (4.25 ~ 9.06) Power Input W Rated Current A Rated Capacity (Range) kw 2.3 (.78 ~ 3.79) 2.9 (.97 ~ 4.20) 3.8 (2.25 ~ 4.80) 5.5 (3.3 ~ 6.68) 7.5 (3.93 ~ 8.38) Input W Rated Current A L/s 47 / 28 / / 28 / / 50 / / 222 / / 36 / 292 db(a) 4 / 35 / 25 4 / 35 / / 40 / / 39 / / 48 / 38 Net (W x D x H) mm 750 x 98 x x 98 x x98 x x 28 x x 258 x 340 Gross (W x D x H) mm 830 x 270 x x 270 x x 270 x x 300 x x 420 x 340 Net / Gross Weight Kg 8 / 0 9 / 9 / 2 / 4 8 / 23 Refrigeration Pipe Size: Liquid / Gas mm Ø6.35 / Ø9.52 Ø6.35 / Ø9.52 Ø6.35 / Ø9.52 Ø6.35 / Ø2.7 Ø Ø2.7 Type Indoor Operating Range o C 7 ~ 30 MINSD020 MINSD026 MINSD035 MINSD052 MINSD070 Power supply V-Ph-Hz 220~ Cooling Heating Airflow (Hi / Med / Lo) INDOOR UNIT - DUCTED Maximum External Static Pressure (Hi) Sound Pressure (Hi / Med / Dimensions Condensate Drain Connection Control db(a) m o C Rated Capacity (Range) kw 2.0 (.7 ~ 3.7) 2.6 (.90 ~ 4.04) 3.5 (2.2 ~ 4.7) 5.2 (3.03 ~ 6.46) 7.0 (4.25 ~ 9.06) Power Input W Rated Current A Rated Capacity (Range) kw 2.3 (.78 ~ 3.79) 2.9 (.97 ~ 4.20) 3.8 (2.25 ~ 4.80) 5.5 (3.3 ~ 6.68) 7.5 (3.93 ~ 8.38) Input W Rated Current A L/s 67 / 50 / / 50 / / 67 / / 70 / / 333 / 303 Pa db(a) 36 / 33 / / 33 / / 36 / / 39 / / 4 / 38 Net (W x D x H) mm 700 x 635 x x 635 x x 635 x x 635 x x 635 x 270 Gross (W x D x H) mm 95 x 655 x x 655 x x 655 x x 655 x x 655 x 350 Net / Gross Weight kg 8 / 23 8 / 23 8 / / / 32 Refrigeration Pipe Size: Liquid / Gas mm Ø6.35 / Ø9.52 Ø6.35 / Ø9.52 Ø6.35 / Ø9.52 Ø6.35 / Ø2.7 Ø Ø2.7 mm OD Ø25 OD Ø25 OD Ø25 OD Ø25 OD Ø25 Type Indoor Operating Range o C 7 ~ 30 3 R40A -5 ~ 50-5 ~ ~ Wireless Remote Control Wired Manual Thermostat Capacities tested in accordance with AS , with 5m interconnecting length for all attached Indoor Units. E & OE

5 INSTALLATION INSTRUCTIONS. Hi-Wall type Selecting installation position Read completely, then follow step by step. Indoor unit Do not expose the indoor unit to external heat or steam. Select a position where there are no obstacles in front or around the unit. Make sure that the condensate drain and pipework can be conveniently routed. Do not install near doorways. Ensure that the clearance to the left and the right Fig. of the unit is more than 2cm. Use a stud finder to locate studs for secure mounting and prevent damage to the wall. The indoor unit should be installed on the wall at a height of 2. metres or more from the floor. The indoor unit should be installed allowing a minimum clearance of 5cm from the ceiling above. Any variations in pipe length may require adjustment to the refrigerant charge. Install away from direct sunlight. The sun may fade the plastic cabinet and affect its appearance. If unavoidable, adequate sunlight prevention should be taken into consideration. More than 2cm More than 5cm More than 20cm More than 2cm Outdoor unit More than 30cm If an awning is built over the outdoor unit to minimise direct sunlight or rain exposure, ensure that the air paths and heat radiation from the condenser is uninhibited. Ensure that the clearance to the back of the unit is more than 30cm and left side is more than 30cm. The front of the unit should have more than 00cm of clearance and the connection side (right side) should have more than 60cm of clearance. Fig.2 Do not place animals or plants in the path of the air inlet or outlet. Take the unit s operating weight into account and select a suitable position to minimise noise and vibration both internally and externally. Select a suitable position so that the air discharge and noise from the unit does not disturb neighbors. More than 30cm More than 00cm More than 60cm Roof installation: If the outdoor unit is installed on a roof structure, ensure it is installed on a secure level base. Ensure the roof structure and securing method are adequate for the unit location. Consult local codes and regulations regarding roof mounting. If the outdoor unit is installed on roof structures or external walls, this may result in excessive noise and vibration, it may also be classed as a non serviceable installation, and void the manufacturers warranty. 4

6 INSTALLATION INSTRUCTIONS Tools required for installation: Spirit level Screwdrivers Electric drill, Hole core drill (φ65mm) Flaring tool set Specified torque wrenches:.8kgf.m, 4.2kgf.m, 5.5kgf.m, 6.6kgf.m (depending on model) Spanners Allen key (4mm) Leak detector Vacuum pump Manifold gauges User manual Thermometer Multimeter Pipe cutter Tape measure De-burring tool Accessories Number Accessory Description Installation Plate Plastic Expansion Sheath Self-tapping Screw A ST3.9X25 Connecting refrigerant pipe Remote control Field supplied parts Consult specifications for the proper sizes. 6 Self-tapping Screw B ST2.9X0 Optional 2 7 Remote controller holder parts 8 Seal 9 0 Drain Joint Liquid side Gas side Transfer connector (Pipe reducer - Packed with the indoor or outdoor unit, depending on model) (NOTE: Pipe sizes differ from unit to unit. To meet different pipe size requirement, depending on the pipe sizes, the pipe reducer may be required to be fitted to the outdoor unit connections.) Magnetic Tyroid (Install on the interconnective cable between indoor unit and outdoor unit after installation.) Qty/unit 5-8 (depending on model) 5-8 (depending on model) Optional part (one piece/indoor unit) Optional part (-5 pieces for outdoor unit, depending on model) Optional part (one piece/one cable) 2 Cord protection sheath (For smaller cables, if the cord clamp cannot fasten the cord please use this sheath to ensure adequate clamping. (on some models) Note: Excepting the above parts provided mentioned above, other parts required are field supplied/purchased. 5

7 INSTALLATION INSTRUCTIONS 2 More than 5cm 3 Air fil ter Air filter Air filter Air filter Remote controller Remote controller 5 Remote controller 4 Remote controller More than 30cm A Air out More than 60cm 6 More than 30cm Air filte r B More tha n 00cm More than 60cm C Loop a connective cable Remote controller Fig.3 One outdoor unit - With two indoor units One outdoor unit - With three indoor units One outdoor unit - With four indoor units One outdoor unit - With five indoor units CAUTION Use a stud finder to locate studs to prevent unnecessary damage to the wall. A minimum pipe run of 3 metres is required to minimise vibration & excessive noise. A, B and C directions should be free from intrusion or obstruction. CAUTION This illustration is for explanation purposes only. The actual style of indoor and outdoor unit may be slightly different. Copper refrigerant lines must be insulated independently 6

8 INSTALLATION INSTRUCTIONS Indoor unit installation (Hi-Wall type). Fit the Installation Plate. Fit the installation plate horizontally on a structural part of the wall with required space around the installation plate. 2. If the wall is made of brick, concrete or the like, drill 5mm diameter holes in the wall. Insert anchor plugs for the appropriate mounting screws. 3. Fit the installation plate on the wall with five or eight type A screws. Note: Fit the Installation Plate and drill holes in the wall according to the wall structure and indoor unit dimensions and the corresponding mounting points on the installation plate. The Installation Plate may be slightly different according to the different models of indoor unit. See Fig.5 for example. Indoor unit outline 20mm or more to wall H Correct orientation of Installation Plate Fig.4 (Dimensions in mm unless otherwise stated) Indoor Unit Dimensions mm(wxh) MINHW x280 MINHW026/ x280 MINHW x35 MINHW070-86x343 L 50mm or more to ceiling Installation plate R Mounting dimensions L (Left) R (Right) Fig.5 20mm or more to wall 2. Drill pipework hole in the wall. Determine hole positions according to the diagram detailed in Fig.5. Drill one () hole (φ65mm) slanting slightly to outdoor side. 2. Always use wall hole conduit when drilling metal grid, metal plate or the like. 3. Condensate drain and refrigerant pipe installation Drainage. Run the condensate drain hose sloping downward. Do not install the drain hose as illustrated in Fig When connecting an extension drain hose, insulate the connecting part of extension drain hose with a shield pipe (See Fig. 8), do not let the drain hose droop or kink. Left rear side refrigerant pipe hole φ65 45 Indoor W Wall Do not block water flow by a rise. Outdoor 5-7mm 45 Do not put the end of drain hose into water. Right rear side refrigerant pipe hole φ65 Fig.6 Fig.7 Fig.8 Refrigerant pipe installation. For the left-hand and right-hand piping, remove the pipe cover from the side panel. 2. For the rear-right-hand and rear-left-hand piping, install the piping as shown in Fig Fix the end of the refrigerant pipe. (Refer to Tightening Connection in REFRIGERANT PIPING CONNECTION) Right-hand piping Rear-right piping 7 Left-hand piping Fig.9 Rear-left piping Fig.0

9 INSTALLATION INSTRUCTIONS 4. Piping and wrapping Bundle the refrigerant pipe, connecting cable, and condensate drain hose with tape securely. Fig Condensate is drained away from the indoor unit via a condensate tray. Do not put any foreign objects in the tray as it may block the drain and cause a water leak. CAUTION Connect the indoor unit first, then the outdoor unit. Ensure the bundled pipework is retained in the rear of the indoor unit. Ensure that the condensate drain falls correctly Insulate the refrigerant pipes individually. Ensure that the condensate drain hose is at the bottom of the bundle. If located at the top of the bundle will cause the condensate tray to overflow inside the unit. Ensure that the power wiring is routed separately to all other wiring. Run the condensate drain hose sloped downward ensure the condensate flows away effectively. Drain hose Indoor unit Connecting cable Fig. Condensate tray Pipe enclosure Connecting pipe Wrapping 4. Indoor unit installation. Pass the piping through the hole in the wall. 2. Put the upper slot at the back of the indoor unit on the upper hook of the installation plate, move the indoor unit from side to side to see that it is securely hooked (see Fig.2). 3. Piping can be manipulated more easily by propping the indoor unit out from the wall with a cushioning material between the indoor unit and the wall. Ensure this is removed after finishing the piping. 4. Push the lower part of the indoor unit onto the wall, then move the indoor unit from side to side, up and down to check it is securely fastened on the installation plate. Fig.2 8

10 3. Ducted type INSTALLATION INSTRUCTIONS Installation precautions. Determine the access route to the installation position. 2. To minimise damage, if possible, move the unit to the installation position with packaging intact. 3. Ensure all wiring is strictly in accordance with relevant local and national standards. Ensure that insulation is in accordance with the standards, in case installation is on a metal part of the building. 4. Avoid installing this system in the following locations, it may cause a malfunction. (if unavoidable, please contact Brivis): A. There is mineral oil present (as in the oil of machinery). B. Highly corrosive environments. (Near the coast) C. Highly caustic environments or near sulfuric gas. (Near hot spring.) D. Areas where the voltage may fluctuate greatly. E. On a mobile apparatus, caravan, mobile home, boat, bus etc... F. In a kitchen or laundry with an overly steamy environment. G. There are strong electromagnetic waves present. H. There are combustible gases or materials present. I. Highly acid or alkaline environments. J. Other especially corrosive or arduous environments. Accessories No Name Qty. Outline Function Insulation pipe Wired remote control Large metal washers Binding tape Water outlet joint 2 8 Pipe joint thermal insulation Indoor unit remote control Indoor unit fixing Binding insulation pipe Outdoor unit drainage Gasket Outdoor unit drainage Copper nut 2 Connecting pipe Condensate drain hose Indoor unit drainage Alkaline batteries (2) Remote signal receiver subassembly Indoor unit installation Installation location Ensure sufficient room for installation and maintenance. Supply air outlet Refrigerant pipe <000mm >250mm <500mm Air return box View A >00mm Supply air Outlet 9 Supply Duct Air return box Ensure that the installation is of sufficient strength to withstand the weight of the unit. Ensure that the air inlet and outlet are not impeded and are not affected by outside air Position so that the unit can distribute air effectively throughout the room. Ensure that refrigerant pipes and condensate drain are accessible. Avoid direct radiation from any external heat sources. <500mm View A <3m >200mm

11 INSTALLATION INSTRUCTIONS Installation of unit Install φ0 (4 pieces) hanging screw bolt (Field Supplied) Locate the hanging rods in accordance with dimensional data as shown in Fig.40. Ensure that the hanging rods are at least φ0mm diameter. Please inspect and verify that the mounting facilities are of sufficient strength to withstand the full operating weight of the unit. Reinforce the structural elements as required. Proceed with the connection of piping and wiring. Determine the piping route to ensure shortest and most accessible route. Ensure wiring is correctly routed before hanging the unit. Install the hang rods according to the different applications shown below: Wooden structure Put a timber across the beams and install the bolts. Timber over the beam Concrete bricks Install the hanging hook with expansible bolt into the concrete. Roof beam Ceiling Hanging screw bolts Fig.34 New concrete bricks Install with insertion or embedding screw. Steel bar Steel roof beam structre Fig.35 Install the supporting angle steel. Hanging screw bolt (Blade shape insertion) (Slide insertion) (Pipe hanging and embedding screw bolt) Hanging bolts Supporting angl e steel Fig.36 Fig.37 Hang the unit Install the hanging screw rod in the unit hanging bracket.. Hang the indoor unit and check that it is level.. Fasten and tighten the hanging rod nuts. Hanging screw bolt Nut (upside) Washer (upside) Hanging bracket Washer (underside) Nut (underside) Fig.38 Spirit level Fasten the nut Fig.39 0

12 Hanging rod position and unit dimension detail INSTALLATION INSTRUCTIONS Unit and Supply air dimensions Return air size Air filter Bottom return air dimensional data Hanging bracket Air filter Electric control box Position of hanging brackets Electric control box Fig.40 MINSD020, 026, 035 MINSD052, 070 External dimensions Supply air outlet size Return air outlet size Hanging bracket A B C D E F G H I J K L M

13 INSTALLATION INSTRUCTIONS How to convert from rear supply air to bottom return air. Remove the bottom access panel and return air spigot. Remove the staples from the side rail. Return air spigot 2. Adhere the sealing sponge (supplied) as shown below. Then fix the bottom access panel to the rear of the unit, and fix the return air spigot to the bottom of the unit. Bottom access panel Side rail Sealing sponge 3. To install the filter, place it on an incline through the return air spigot, and push up into place. 4. The configuration change is complete when the filter fixing blocks are positioned in the relevant holes. Fig.4 NOTE All the figures in this manual are for explanation purpose only. There may be slight differences depending on the model purchased. Alway check the physical unit for actual detail. 7 2

14 INSTALLATION INSTRUCTIONS Condensate drain CAUTION Ensure that the condensate drain pipe and its connections are properly insulated to prevent condensation and water leaks. Connect the pipe with appropriate adhesive to ensure a proper fit with no leaks. Do not put undue stress on the condensate fittings, it may cause the pipe to break and leak. The downward slope of the condensate drain pipe should be at least :50, do not bend or let droop. Condensate drain pipe length shall be less than 20m. Install pipe supports as required to prevent the pipe from drooping and trapping condensate. Refer to the figures for correct installation procedure..5m~2m Slope downward at least :50 Fig.44 Fold Bend Fig.45 Supporting Unit Installation accessories Duct design - Low Static (40-70Pa) This is a low static unit, ensure that the duct is as short as possible to minimise static pressure. Use a flexible duct connection on the supply and return air spigots to isolated any vibration. As deep as possible (at least 0cm) Slope downward at least :50 Fig.46 Duct installation Fix the ducts onto the spigots. NOTE:.Do not let the indoor unit bear the weight of duct. Support the ducts independently of the unit. 2.Allow adequate space for service and maintenance. 3.In noise critical spaces like meeting rooms or bedrooms, use acoustic duct and/or additional insulation to minimise noise. Acoustic duct and insulation are field supplied 3

15 INSTALLATION INSTRUCTIONS Outdoor unit installation Outdoor installation precaution Install the outdoor unit on a firm rigid base to prevent minimise noise and vibration. Position the unit so the condenser air discharge is free of obstruction. If the unit is exposed to strong prevailing winds, such as in coastal areas ensure that the condenser air discharge is positioned properly by placing the unit lengthwise along the wall, or by using a wind deflector. In especially windy areas, use an alternative installation position to prevent influence from the strong breeze. If installed on a wall or roof bracket, ensure that the bracket is of sufficient strength to withstand the operating weight of the unit. For wall mounted applications, the wall should be of solid brick, concrete or the similar construction. Appropriate reinforcement may be required to support the unit. The connection between the bracket and wall, and bracket and the unit should be firm, stable and reliable. Ensure there are no obstructions to the air inlets or outlets. Strong wind Fig.5 Fixing the outdoor unit Anchor the outdoor unit with φ0 or φ8 bolts tightly. Ensure the unit is level and secure. Outdoor unit dimensions mm Mounting dimensions (L x H x W) L2 (mm) W2 (mm) MON2H x700x MON3H076 & MON4H x860x MON5H05-990x965x MON5H36-938x369x Fig.52 4

16 REFRIGERANT PIPE CONNECTION Outdoor drain joint installation NOTE: The drain joint is product specific. Fit the seal to the drain joint, then insert the drain joint into the base pan hole of outdoor unit. o Rotate the joint 90 to lock in place. Connect the drain joint with a drain hose (field supplied), and drain to waste. The drain is required to drain the water produced by the unit in heating mode, including defrost. Seal Drain joint () (2) Base pan hole of outdoor unit Seal Drain pipe Refrigerant pipe connection. Pipe flaring The primary cause of refrigerant leaks is defective pipe flared connections. Follow the correct flaring procedure as detailed below: A: Cut the pipes to length.. Only use new, clean, refrigerant grade copper pipe. 2. Measure the distance between the indoor and the outdoor unit. 3. Cut the pipes square and slightly longer than the measured distance. B: Burr removal. Remove all burrs completely from the cut cross section of pipe. 2. Hold the end of the copper pipe down as you remove the burrs. This will prevent the burrs falling into the refrigerant pipe. Fig Angled Uneven Burred Fig.54 Pipe Reamer/Deburrer Point down Fig.55 Flare nut C: Put the flare nut on Remove the flare nuts attached to indoor and outdoor units. Put them on the pipe after removing the burrs. Flare nuts cannot be put on the pipe after the flares have been made. D: Flaring the pipe Hold the copper pipe firmly in a die, in accordance with the dimensions shown in the table below. Outer diam. (mm) Max. A(mm) Min Bar Copper tube "A" Fig.56 Bar Copper pipe Clamp handle Handle Yoke Cone 5 Fig.57

17 REFRIGERANT PIPE CONNECTION Tightening flare connection Align the centrelines of the pipes. Tighten the flare by hand at first, then tighten to the torque setting as detailed in the table below. Use two spanners as shown in Fig. 59 Pipe Flare nut Pipe Fig.58 Outside diameter Tightening Additional tightening torque(n.cm) torque(n.cm) (53kgf.cm) (63kgf.cm) 2500 (255kgf.cm) 3500 (357kgf.cm) 2600 (265kgf.cm) 3600 (367kgf.cm) Caution Excessive torque can break the flare nut. Use only specified torque. Fig.59 Selecting a 7.0kW Indoor Unit When selecting a 7.0kW indoor unit, it must be connected to the A circuit on the outdoor unit to ensure the appropriate pipe size for a unit of this size. See Fig. 60 Pipe sizes for all indoor units is as follows: Indoor Unit Capacity kw Liquid (mm/in) Gas (mm/in) 2.0 / 2.5 / / / / / / / / 3/ / / / 5/8 C (6.35 / /4) C (9.53 / 3/8) B (6.35 / /4) B (9.53 / 3/8) A (6.35 / /4) A (2.70 / 5/8) Electrical work Electric safety regulations for installation. If there is a serious safety issue regarding the power supply, technicians should refuse to install the system, and fully explain the issue to the client to gain a resolution. 2. Power supply voltage should be in the range of 90%~0% of rated voltage. 3. A circuit breaker and main power switch adequately sized to accommodate the maximum input current of the unit should be installed in power circuit. 4. Ensure that the system is earthed properly. 5. Wiring shall be in accordance with the Electrical Connection Diagram located on the access panel of the outdoor unit. 6. All wiring must comply with all local and national electrical standards and codes and be installed by qualified and skilled electricians. 7. An individual electrical circuit and single power outlet must be used for the unit. Do not share the electrical circuit with other electrical devices. 6 Fig.60

18 ELECTRICAL WORK Wiring connection NOTE: Before performing any electrical work, turn off the mains power to the system. CAUTION Do not touch the capacitors even if you have disconnected the power. A stored electrical charge may be evident, causing an electrical shock. For your safety, wait at least 5 minutes after the power has been turned off to start work on the system. Minimum nominal cross-sectional area of conductors: Rated current of appliance (A) >3 and <6 >6 and <0 >0 and <6 >6 and <25 Nominal cross-sectional 2 area (mm) Power is supplied from the outdoor unit. The indoor units are connected with power and signal wires. Ensure they are correctly connected, otherwise the system may not run, or will run abnormally. NOTE: The cable size and the current rating of the circuit breaker are determined by the maximum current on the nameplate, located on the side panel of the unit. Please refer to the nameplate before selecting the cable, circuit breaker and/or switch. Please refer to the above tables and choose the appropriate cable size to suit the electrical requirements of the system. Connect the cable to the outdoor unit. Remove the electrical control board cover from the outdoor unit by loosening the screw as shown in Fig.6 2. Connect the electrical cables to the terminals as identified with their respective matched terminals on the terminal blocks of the indoor and outdoor units. 3. Secure the cable onto the control board with the cord clamp. 4. To prevent the ingress of water, form a loop in the connecting cables as illustrated in the installation diagram of the indoor and outdoor units. 5. Isolate any exposed wires/cables with electrical terminators. Arrange the wiring to ensure it does not touch any electrical or metal parts. Fig.6 Connection Cable 0mm 40mm Fig.62 Screw Cover CAUTION Be sure to connect the indoor units (A, B, C, D, E) to the Active and Neutral terminals of the signal wires (A, B, C, D, E) of outdoor unit as identified with their respective matched terminals. Incorrect/incomplete wiring connections may cause the system to malfunction. 7 POWER Connective cable of indoor unit and outdoor unit Connective cable of indoor unit and outdoor unit Connective cable of indoor unit and outdoor unit Connective cable of indoor unit and outdoor unit One-two One-three One-four One-five E Connective cable of indoor unit and outdoor unit E

19 ELECTRICAL WORK NOTE: Please refer to the following diagrams for the wiring connections for the various models. Please run the main power cord through the lower line-outlet of the cord clamp. One Outdoor - Two Indoor models: L N L(A) N(A) S(A) L(B) N(B) S(B) POWER TO A TO B One Outdoor - Three Indoor models: L N L(A)N(A)S(A) POWER TO A L(B)N(B)S(B) L(C)N(C)S(C) TO B TO C One Outdoor - Four Indoor models: L N L(A)N(A)S(A) POWER L(B) N(B) S(B) L(C) N(C) S(C) L(D) N(D) S(D) CAUTION CAUTION CAUTION ) An individual power circuit must be used for this system. Wiring shall be conducted in accordance with the unit circuit diagram, and these installation instructions. 2) The screws which fasten the wiring within the electrical switchboard may come loose from vibration in transportation. Please ensure that all electrical connections within the unit are sufficiently tightened. Loose connections may cause overheating at the terminals, leading to an electrical failure or malfunction. 3) Confirm the suitability of the power source. 4) Confirm that electrical capacity is sufficient for the operating current of the system. 5) Ensure that the starting voltage is maintained at more than 90 percent of the rated voltage marked as marked on the name plate. 6) Confirm that the cable thickness is suitable for the power source specification. 7) Always use an adequately sized circuit breaker. 8) The following issues may be caused by voltage drop. Vibration/chattering of contactors, which will damage the contact points, blown fuses breaking, overload and/or malfunction of the system. 9) Before accessing the electrical terminals, disconnect all power from the system. TO A TO B TO C TO D One Outdoor - Five Indoor models: Compressor / Power Supply Information L N L(A)N(A)S(A) L(B) N(B) S(B) L(C) N(C) S(C) L(D) N(D) S(D) L(E) N(E) S(E) Compressor start/stop Stop time Minimum 3 minutes POWER Voltage variance Within +/- 0% of supply voltage Power supply voltage Voltage drop Voltage imbalance Within +/- 5% of supply voltage Within +/- 3% of supply voltage TO A TO B TO C TO D TO E 8

20 Air purging Air and/or moisture in the refrigerant system can have undesirable effects as indicated below: Higher system operating pressures. Higher system operating current. Performance and efficiency loss Moisture in the refrigerant circuit may freeze and cause blockages in the system. Water may lead to corrosion of key components in the refrigeration system. Therefore, the system components, indoor, outdoor and refrigerant pipe between the units must be leak tested and evacuated thoroughly to remove any non-condensables and/or moisture from the system. Air purging with vacuum pump REFRIGERATION Preparation: Please refer to Page 8 of this manual for specific pipe length and height specifications. Check that all piping (both liquid and gas side pipes) between the indoor and outdoor units have been properly connected and all wiring has been completed. Remove the service valve caps from both the gas and the liquid side on the outdoor unit. Note that both the liquid and gas side service valves on the outdoor unit are to be kept closed at this stage. System charging The outdoor unit is charged for a nominal 0m pipe length for each indoor unit up to the maximum no. of indoor units (2-Head Outdoor 20m, 3-Head Outdoor 30m, 4-Head Outdoor 40m & 5-Head Outdoor 50m). The total system refrigerant charge must be adjusted according to the table below: System Refrigerant Adjustment - Calculated for each Indoor Unit Less than 0m pipe length More than 0m pipe length REMOVE Refrigerant ADD Refrigerant 5g/m for Ø 6.35mm Liquid Line or 5g/m for Ø 6.35mm Liquid Line Example FIVE Indoor Units ( kW) - 5 Head Outdoor Unit pre-charged for 50m Indoor Unit Size (kw) Actual Length (m) Pre-charged Pipe Length Variance (m) Liquid Line Size (mm) Indoor Unit Charge Adjustment (g/m) System Charge Adjustment (g) Unit Ø Unit Ø Unit Ø Unit Ø Unit Ø Total System Length 62 Total System Refrigerant Adjustment (g) 20 In this example, an additional 240g of refrigerant is required to be ADDED to the system 9

21 REFRIGERATION System charging (cont) Example 2 FOUR Indoor Units ( kW) - 5 Head Outdoor Unit pre-charged for 50m Indoor Unit Size (kw) Actual Length (m) Pre-charged Pipe Length Variance (m) Liquid Line Size (mm) Indoor Unit Charge Adjustment (g/m) System Charge Adjustment (g) Unit Ø Unit Ø Unit Ø Unit Ø Unit Ø Total System Length 42 Total System Refrigerant Adjustment (g) -60 In this example, 60g of refrigerant is required to be REMOVED from the system. In these instances, the amount of refrigerant for the not connected indoor unit is calculated using the Ø6.35mm liquid line size (i.e. 5g/m). When relocating the system to another place, fully evacuate and seal the system. Make sure the any additional refrigerant is added in liquid form. Outdoor unit A B Service valve Gas side Indoor unit C Liquid side D Flare connection Take caution in handling the service valve Fully open the valve stem until it hits against the stop. Do not try to open it further. Securely tighten the valve stem cap with a spanner. Valve stem cap tightening torque (See Tightening torque table on page 6). Fig.65 Flare nut Valve Cap Valve body Valve stem Fig.66 20

22 Using the vacuum pump. Completely tighten the flare nuts, A, B, C, D, E connect the manifold valve charge hose to a charge port of the low-pressure valve on the gas pipe side. 2. Connect the charge hose connection to the vacuum pump. 3. Fully open the Lo tap of the manifold gauges. 4. Turn on the vacuum pump to evacuate. After starting evacuation, slightly loosen the flare nut of the Lo tap on the gas pipe side and check that air is entering. (The operating noise of the vacuum pump changes and the compound gauge indicates 0 instead of negative) 5. After the evacuation is complete, fully close the Lo tap of the manifold gauges and turn off the vacuum pump. Evacuate the system for 5 minutes or more and check that the compound gauges indicate -76cm Hg or 5 (-x0 Pa). 6. Turn the stem of service valve B about 45 counterclockwise for 6~7 seconds after the gas coming out, then tighten the flare nut again. Make sure the pressure display in the pressure gauge is higher than the atmospheric pressure. 7. Remove the charge hose from the Lo pressure charge hose. 8. Fully open the service valve stems B and A. 9. Securely tighten the caps of the service valve. o Manifold Compound gauges -76cm Hg Lo tap Charge hose Low pressure valve REFRIGERATION Fig.67 Hi tap Charge hose Vacuum pump Electrical safety and leak check Electrical safety check Perform a thorough electrical safety check after completing installation:. Insulated resistance The insulated resistance must be more than 2MΩ. Indoor unit check point n m k j i h 2. Earthing After completing the wiring installation, visually check the earthing and measure for earth leakage, it must be less than 4 Ω. Outdoor unit check point A B C f e d c b 3. Electrical leakage check (performing during test running) After finishing the installation, test run the system. The system must be check electrically using a multi-meter and other test tools to perform the check. Turn off the system immediately if leakage is present. Diagnose the issue and resolve before completing the system commissioning.. Fig.68 a 2

23 TEST RUNNING Refrigerant leak test. Soapy water method: Apply a soapy water solution to the indoor and outdoor unit connections using a soft brush. If there are bubbles observed at the connections, this is confirmation of a refrigerant leak. The leak must be repaired before restarting. 2. Leak detector Use a handheld leak detector to check for leaks. Outdoor unit check point Indoor unit check point CAUTION A: Lo service valve B: Hi service valve C and D are the ends of indoor unit connection. NOTE: This diagram is for illustration purposes only. The actual order of the A, B, C, D & E connections on the system may differ slightly from the unit to unit depending on the model. Check the actual system for final configuration. A,B,C,D are points for one outdoor-four indoor systems. A,B,C,D, E are points for one outdoor-five indoor systems. Fig.69 E Commissioning / Test run Perform a test operation after completing a leak test at the flare nut connections and after a full electrical safety check. Check that all pipe work and wiring have been properly connected. Check that the gas and liquid service valves are fully open.. Connect the power, press the ON/OFF button on the remote control to turn the unit on. 2. Use the MODE button to select COOL, HEAT, AUTO and FAN to check the operation of all of the functions. o 3. When the ambient temperature is too low (lower than 7 C), the unit cannot be controlled by the remote control to run in cooling mode, but manual operation can be selected. Manual operation is used only when the remote control is disabled or maintenance is necessary. Hold the indoor unit front panel sides and lift the panel up to an angle until it clicks, and remains open at an angle. Press the Manual control button to select the AUTO or COOL, the unit will operate under a Forced AUTO or COOL mode (see User Manual for details). 4. The test operation will last for approximately 30 minutes. Manual control button AUTO/COOL Fig

24 For all your Sales and Service enquiries call us on 300 BRIVIS ( ) Brivis Australia 6 Malcolm Rd Braeside Victoria 395 Australia 300 BRIVIS ( ) Fax: +6 (03) sales@brivis.com.au Brivis New Zealand Distributor: Warm Air Ltd 69 Marsden Street Lower Hutt 500 New Zealand PO Box Wellington Mail Centre Wellington 5043 New Zealand 0800 WARMAIR ( ) Ph: +64 (04) Fax: +64(04) sales@warmair.co.nz Brivis South Africa Distributor: Lorenz and Associates Northlands Deco Park Cnr Witkoppen and Newmarket Roads North Riding, Johannesburg South Africa BRIVIS ( ) Ph: +27 (0) Fax: +27 (0) info@brivis.co.za 203 Brivis Climate Systems Pty. Ltd. All rights reserved. No part of these documents may be used in any way or form without prior written consent from Brivis Climate Systems Pty Ltd. Part Number: B06894 December 204 Brivis Climate Systems Pty. Ltd. ABN AU24752 Version 4 Specifications subject to change without notice. 203 Brivis Climate Systems Pty. Ltd.

INVERTER SPLIT - TYPE

INVERTER SPLIT - TYPE INVERTER SPLIT - TYPE ISSUE No 2 DATE 04/09/08 P/No 2020323A2868 CONTENTS SAFETY PRECAUTIONS Warning 2 Operating temperature 2 BEFORE INSTALLATION Tools needed for installation 3 Items required for installing

More information

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump COMFORT...BUILT TO LAST 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump INSTALLATION MANUAL INDOOR UNIT: 1PAMSH09-SZW-14.5 1PAMSH09-SZW-15 1PAMSH12-SZW-15 1PAMSH18-SZW-15

More information

ROOM AIR CONDITIONER INSTALLATION MANUAL

ROOM AIR CONDITIONER INSTALLATION MANUAL ROOM AIR CONDITIONER INSTALLATION MANUAL (Inverter Split Type) Please read this installation manual completely before installing the product When the power cord is damaged, replacement work shall be performed

More information

SPLIT-TYPE ROOM AIR CONDITIONER

SPLIT-TYPE ROOM AIR CONDITIONER Before using your air conditioner, please read this manual carefully and keep it for future reference SPLIT-TYPE ROOM AIR CONDITIONER Please read this installation manual completely before installing the

More information

INVERTER SPLIT -TYPE ROOM AIR CONDITIONER

INVERTER SPLIT -TYPE ROOM AIR CONDITIONER Before using your air conditioner, please read this manual carefully and keep it for future reference. INVERTER SPLIT -TYPE ROOM AIR CONDITIONER Please read this installation manual completely before installing

More information

Choosing the installation site. Installation. 07 Choosing the installation site

Choosing the installation site. Installation. 07 Choosing the installation site Installation Installation warnings: 1. Carefully read the installation manual before beginning. 2. Follow each step as shown. 3. Observe all local, state, and national electrical codes and by qualified,

More information

INVENTER SPLIT -TYPE ROOM AIR CONDITIONER

INVENTER SPLIT -TYPE ROOM AIR CONDITIONER Before using your air conditioner, please read this manual carefully and keep it for future reference INVENTER SPLIT -TYPE ROOM AIR CONDITIONER Please read this installation manual completely before installing

More information

SPLIT -TYPE ROOM AIR CONDITIONER

SPLIT -TYPE ROOM AIR CONDITIONER Before using your air conditioner, please read this manual carefully and keep it for future reference. SPLIT -TYPE ROOM AIR CONDITIONER iqool9 iqool2 iqool8 iqool24 Please read this installation manual

More information

R410A SPLIT SERIES DC INVERTER

R410A SPLIT SERIES DC INVERTER R410A SPLIT SERIES DC INVERTER Models ECO906SD ECO908SD ECO1206SD ECO1208SD ECO1806SD Read This Manual Inside you will find many helpful hints on how to use and maintain your air conditioner properly Just

More information

SINGLE - ZONE Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual

SINGLE - ZONE Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual Presents SINGLE - ZONE Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual 9k,12k 18k 24k, 30k, 36k ECR International, Inc. 2201 Dwyer Avenue, Utica NY 13501 Phone: 800.325.5479

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC AQB8J6WC_IM_E_25864 2006.4.4 3:29 PM Page 7 INSTALLATION MANUAL Indoor Unit AQB8J6WC AQB24J2WC Outdoor Unit UQB8J6WC UQB24J2WC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC AQB09JJ6WC_IM_E_2585 2006.4.17 4:26 PM Page 17 INSTALLATION MANUAL Indoor Unit AQB09JJWC AQB12JJWC Outdoor Unit UQB09JJWC UQB12JJWC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

Installation Manual. KS Series KS09 KS12 KS18 KS24 KS28. J3387_Kaden_Installer_Manual_ indd 1

Installation Manual. KS Series KS09 KS12 KS18 KS24 KS28. J3387_Kaden_Installer_Manual_ indd 1 Wall Mounted AIR CONDITIONER Installation Manual KS Series KS09 KS12 KS18 KS24 KS28 J3387_Kaden_Installer_Manual_050917.indd 1 5/09/2017 9:07 AM J3387_Kaden_Installer_Manual_050917.indd 2 5/09/2017 9:07

More information

Installation. All about the. of your. Split Type Room Air Conditioner. Refer to Page 2 for table of contents.

Installation. All about the. of your. Split Type Room Air Conditioner. Refer to Page 2 for table of contents. All about the Installation of your Split Type Room Air Conditioner Refer to Page 2 for table of contents. www.frigidaire.com USA 1-866-942-1567 www.frigidaire.ca Canada 1-866-942-1567 2020323B2335 (June

More information

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13 R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.

More information

Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241

Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241 Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241 Please read this user manual first! Dear Customer, Thank you for preferring a Beko product.

More information

QUICK CONNECT INSTALLATION MANUAL DUCTLESS MINI-SPLIT SYSTEM FOR MODELS: 2PAMSHQC12 2PAMSHQC18 2PAMSHQC24 2PAMSHQC36

QUICK CONNECT INSTALLATION MANUAL DUCTLESS MINI-SPLIT SYSTEM FOR MODELS: 2PAMSHQC12 2PAMSHQC18 2PAMSHQC24 2PAMSHQC36 QUICK CONNECT DUCTLESS MINI-SPLIT SYSTEM INSTALLATION MANUAL FOR MODELS: 2PAMSHQC12 2PAMSHQC18 2PAMSHQC24 2PAMSHQC36 Before using your air conditioner, please read this manual carefully and keep it for

More information

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT SWING LRSWING Installation Manual Split Type Wall Mounted Air Conditioner COOL RUN C SPEED TURBO ON/OFF FAN COOL HEAT SWING SWING Rinnai Systems Models System Indoor Outdoor HSNRQ25B HINRQ25B HONRQ25B

More information

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units Installation and Operation Manual CMA12SB-0 Series Horizontal/Side Discharge Condensing Units 517.787.2100 www.marsdelivers.com www.heatcontroller.com Heat Controller CONTENTS PAGE 1. PRES... 1 2. INSTALLATION

More information

Brivis Ducted Reverse Cycle Inverter. Installation Manual. Please read this manual carefully prior to installation

Brivis Ducted Reverse Cycle Inverter. Installation Manual. Please read this manual carefully prior to installation Brivis Ducted Reverse Cycle Inverter Installation Manual Please read this manual carefully prior to installation CONTENTS PAGE PRES... INSTALLATION INFORMATION... ACCESSORIES... 3 INSPECTING AND HANDLING

More information

Installation Instructions

Installation Instructions 40MAQ High Wall Ductless Split System Sizes 09 to 36 Installation Instructions NOTE: Read the entire instruction manual before starting the installation TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS 2 PARTS

More information

Horizontal/Side Discharge Condensing Units

Horizontal/Side Discharge Condensing Units INSTALLATION, OPERATION & MAINTENANCE MANUAL Horizontal/Side Discharge Condensing Units Models CMA12SD-0 CMA18SD-1 CMA24SD-1 CMA30SD-1 CMA36SD-1 CMA48SD-1 517.787.2100 www.marsdelivers.com Horizontal/Side

More information

Split Air Conditioner

Split Air Conditioner Change for Life Split Air Conditioner Installation Manual Residential Air Conditioners MODEL: GWC09AB-D3DNA2D GWC12AB-D3DNA2D GWC18AC-D3DNA2D GWC24AC-D3DNA2D GWH09AB-D3DNA2D GWH12AB-D3DNA2D GWH18AC-D3DNA2D

More information

Installation Instructions

Installation Instructions 40MBFQ Floor Console Ductless System Sizes 09 to 58 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING... 4 DIMENSIONS... 5 CLEARANCES...

More information

SPLIT -TYPE ROOM AIR CONDITIONER

SPLIT -TYPE ROOM AIR CONDITIONER efore using your air conditioner, please read this manual carefully and keep it for future reference. SPLIT -TYPE ROOM IR CONDITIONER The design and specifications are subject to change without prior notice

More information

DUCTLESS MINI-SPLIT INSTALLATION MANUAL FOR MODELS: 1PAMSHQCW PAMSHQCW12-15 COMFORT...BUILT TO LAST 12,000 BTU / 15 SEER QUICK CONNECT

DUCTLESS MINI-SPLIT INSTALLATION MANUAL FOR MODELS: 1PAMSHQCW PAMSHQCW12-15 COMFORT...BUILT TO LAST 12,000 BTU / 15 SEER QUICK CONNECT COMFORT...BUILT TO LAST 12,000 BTU / 15 SEER QUICK CONNECT DUCTLESS MINI-SPLIT With 11,500 BTU Heat Pump INSTALLATION MANUAL FOR MODELS: 1PAMSHQCW12-15 Indoor Wall Unit 1PAMSHQCW12-15 Outdoor Condenser

More information

- INVERTER SPLIT TYPE ROOM AIR CONDITIONER

- INVERTER SPLIT TYPE ROOM AIR CONDITIONER Before using your air conditioner, please read this manual carefully and keep it for future reference. - INVERTER SPLIT TYPE ROOM AIR CONDITIONER SERIES Please read this installation manual completely

More information

Installation Manual SPLIT-TYPE ROOM AIR CONDITIONER

Installation Manual SPLIT-TYPE ROOM AIR CONDITIONER SPLIT-TYPE ROOM AIR CONDITIONER Installation Manual IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.

More information

Installation Manual. WAS / WYS Series. For 9,000-36,000 BTU/hr Systems. Inverter+ and Inverter++ Models

Installation Manual. WAS / WYS Series. For 9,000-36,000 BTU/hr Systems. Inverter+ and Inverter++ Models DUCTLESS MINI SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP WAS / WYS Series WAS: Cooling Only Version WYS: Cooling and Heating Version Inverter+ and Inverter++ Models For 9,000-36,000 BTU/hr Systems Installation

More information

DUCTLESS MINI-SPLIT INSTALLATION MANUAL COMFORT...BUILT TO LAST

DUCTLESS MINI-SPLIT INSTALLATION MANUAL COMFORT...BUILT TO LAST COMFORT...BUILT TO LAST SINGLE ZONE DUCTLESS MINI-SPLIT INSTALLATION MANUAL 2PAMS SERIES Before using your air conditioner please read this manual carefully and keep it for future reference, along with

More information

Installation and Operation Manual. SVH Series. Inverter Single Zone Ductless Mini-Split SVH09SA-0 SVH09SA-1 SVH12SA-0 SVH12SA-1 SVH18SA-1 SVH24SA-1

Installation and Operation Manual. SVH Series. Inverter Single Zone Ductless Mini-Split SVH09SA-0 SVH09SA-1 SVH12SA-0 SVH12SA-1 SVH18SA-1 SVH24SA-1 Installation and Operation Manual SVH Series Inverter Single Zone Ductless Mini-Split SVH09SA-0 SVH09SA-1 SVH12SA-0 SVH12SA-1 SVH18SA-1 SVH24SA-1 www.marsdelivers.com Table of Contents Installation Manual

More information

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS DLCLRA INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 Fig. 1 - Size 36 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING...

More information

CENTRAL AIR CONDITIONER SPLIT SYSTEM

CENTRAL AIR CONDITIONER SPLIT SYSTEM CENTRAL AIR CONDITIONER SPLIT SYSTEM WITH ELECTRONIC CONTROL SERIES: DS INSTALLATION INSTRUCTIONS INDEX GENERAL... 2 UNIT LOCATION CRITERIA... 2 DIMENSIONAL DRAWINGS... 3 INDOOR UNIT INSTALLATION... 5

More information

Installation Instructions

Installation Instructions 38MHR Outdoor Unit Single Zone Ductless System Sizes 09 to 24 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. NOTE: Images are for illustration purposes

More information

Installation Manual Forest Series All Model Numbers

Installation Manual Forest Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER Installation Manual Forest Series All Model Numbers CS78421-548-754 IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit.

More information

Installation Manual. Aurora Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

Installation Manual. Aurora Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS SPLIT-TYPE ROOM AIR CONDITIONER Installation Manual Aurora Series All Model Numbers IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to

More information

Please read this manual carefully before installation and keep it for future reference. CONTENTS. Installation Manual. DIY Series

Please read this manual carefully before installation and keep it for future reference. CONTENTS. Installation Manual. DIY Series Please read this manual carefully before installation and keep it for future reference. CONTENTS Installation Manual DIY Series The design and specifications are subject to change without prior notice.

More information

Installation Instructions

Installation Instructions 40MAQ High Wall Ductless System Sizes 09 to 36 Installation Instructions NOTES: Read the entire instruction manual before starting the installation. Images are for illustration purposes only. Actual models

More information

Installation Instructions

Installation Instructions 40MBFQ Floor Console Ductless System Sizes 09 to 12 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS... 5 CLEARANCES... 5

More information

DVC/DVH Series. Inverter Single Zone Ductless Mini-Split A-DVC/DVH 09SF A-DVC/DVH 12SF A-DVC/DVH 18SF A-DVC/DVH 24SF

DVC/DVH Series. Inverter Single Zone Ductless Mini-Split A-DVC/DVH 09SF A-DVC/DVH 12SF A-DVC/DVH 18SF A-DVC/DVH 24SF Installation Manual DVC/DVH Series Inverter Single Zone Ductless Mini-Split A-DVC/DVH 09SF A-DVC/DVH 12SF A-DVC/DVH 18SF A-DVC/DVH 24SF B-DVC/DVH 09SF B-DVC/DVH 12SF B-DVC/DVH 18SF B-DVC/DVH 24SF www.marsdelivers.com

More information

UltraV Series Outdoor Units

UltraV Series Outdoor Units INSTALLATION MANUAL UltraV Series Outdoor Units Models A-VMH18DU-1 A-VMH28TU-1 A-VMH36QU-1 517.787.2100 www.marsdelivers.com Table of Contents Installation Manual 1 2 3 4 5 Accessories... 4 Safety Precautions...

More information

SPLIT WALL-MOUNTED AIR CONDITIONER

SPLIT WALL-MOUNTED AIR CONDITIONER SPLIT WALL-MOUNTED AIR CONDITIONER MODELS: WS 090C / WS 090H / WS00H EMAILAIR I N S T A L L A T I O N I N S T R U C T I O N S ACCESSORIES SUPPLIED WITH THE AIR CONDITIONER 2 LOCATION OF INDOOR AND OUTDOOR

More information

DAIKIN AIR CONDITIONER

DAIKIN AIR CONDITIONER 3P226011-1A M07B242A DAIKIN AIR CONDITIONER Two-dimensional bar code is a code for manufacturing. Safety Precautions (1) Read these Safety Precautions carefully to ensure correct installation. This manual

More information

Installation Manual. All Model Numbers SERIES SPLIT-TYPE ROOM AIR CONDITIONER

Installation Manual. All Model Numbers SERIES SPLIT-TYPE ROOM AIR CONDITIONER SERIES SPLIT-TYPE ROOM AIR CONDITIONER Manual All Model Numbers IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for

More information

Installation Manual. Forest Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER

Installation Manual. Forest Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER SPLIT-TYPE ROOM AIR CONDITIONER Installation Manual Forest Series All Model Numbers IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to

More information

Installation Manual. KSIF Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER

Installation Manual. KSIF Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER SPLIT-TYPE ROOM AIR CONDITIONER Installation Manual KSIF Series All Model Numbers IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to

More information

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO ) SPLIT TYPE ROOM AIR CONDITIONER INSTALLATION MANUAL (PART NO. 9312791019-01) This air conditioner uses new refrigerant HFC (R410A). The basic installation work procedures are the same as conventional refrigerant

More information

SPLIT -TYPE ROOM AIR CONDITIONER

SPLIT -TYPE ROOM AIR CONDITIONER Before using your air conditioner, please read this manual carefully and keep it for future reference. PLIT -TYPE ROOM AIR CONDITIONER The design and specifications are subject to change without prior

More information

Exceptional Service and Warranty. Ultimate in Total Comfort. Energy Efficient and Superior Design. Brivis DRC Series. Summer Cool and Winter Warmth

Exceptional Service and Warranty. Ultimate in Total Comfort. Energy Efficient and Superior Design. Brivis DRC Series. Summer Cool and Winter Warmth Ultimate in Total Comfort Brivis Ducted Reverse Cycle (DRC) air conditioning gives you total climate control and comfort with the convenience and flexibility to cool and heat your home just how you like

More information

SPLIT -TYPE ROOM AIR CONDITIONER

SPLIT -TYPE ROOM AIR CONDITIONER efore using your air conditioner, please read this manual carefully and keep it for future reference. SPLIT -TYPE ROOM IR CONDITIONER The design and specifications are subject to change without prior notice

More information

Inverter Room Air Conditioner Installation Manual KSV26CRC, KSV26HRC, KSV35CRC, KSV35HRC, KSV53HRC, KSV62HRC, KSV70CRC, KSV70HRC, KSV80HRC

Inverter Room Air Conditioner Installation Manual KSV26CRC, KSV26HRC, KSV35CRC, KSV35HRC, KSV53HRC, KSV62HRC, KSV70CRC, KSV70HRC, KSV80HRC Inverter Room Air Conditioner Installation Manual KSV26CRC, KSV26HRC, KSV35CRC, KSV35HRC, KSV53HRC, KSV62HRC, KSV70CRC, KSV70HRC, KSV80HRC Refrigerant R410A Congratulations Contents Congratulations and

More information

Installation Manual. SYSPLIT WALL FLEXI Series SPLIT-TYPE ROOM AIR CONDITIONER

Installation Manual. SYSPLIT WALL FLEXI Series SPLIT-TYPE ROOM AIR CONDITIONER SPLIT-TYPE ROOM AIR CONDITIONER Installation Manual SYSPLIT WALL FLEXI Series IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save

More information

Installation manual for room air conditioner

Installation manual for room air conditioner Installation manual for room air conditioner HSU-26HEK03/R2(D)/I HSU-35HEK03/R2(D)/I HSU-53HEK03/R2(D)/I HSU-71HEK03/R2(D)/I HSU-26HEK03/R2(D)/O HSU-35HEK03/R2(D)/O HSU-53HEK03/R2(D)/O HSU-71HEK03/R2(D)/O

More information

Installation Instructions

Installation Instructions 8GXM / 0GXM Multi---Split High---Wall Duct Free Split System 8GXM --- Size 18k, k, and 0k 0GXM --- Size 9k, 1k, and 18k Installation Instructions NOTE: Read the entire instruction manual before starting

More information

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO AOYG8LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL For authorized service personnel only. English PART NO. 93778639 93778639_IM.indb /20/20 6:07:25 PM AIR CONDITIONER OUTDOOR UNIT INSTALLATION

More information

Split Air Conditioner

Split Air Conditioner Split Air Conditioner Owner's Manual Residential Air Conditioners Thank you for choosing Residential Air Conditioners,please read this owner s manual carefully before operation and retain it for future

More information

Installation Manual. Aurora Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER

Installation Manual. Aurora Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER SPLIT-TYPE ROOM AIR CONDITIONER Installation Manual Aurora Series All Model Numbers 2925CP65 292CP565 2925CP66 292CP566 2925CP67 292CP567 2925CP68 292CP568 CS78421-548-754 IMPORTANT NOTE: Read this manual

More information

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS DLCSRA INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 NOTES: Read the entire instruction manual before starting the installation. Images are for illustration purposes only.

More information

Brivis Compact Classic Ducted Gas Heater

Brivis Compact Classic Ducted Gas Heater Brivis Compact Classic Ducted Gas Heater Installer s Manual PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLING THIS PRODUCT i Scope This Installer's Manual is intended to be used as a guideline

More information

OWNER S AND INSTALLATION MANUAL RAV-480FS2B/RAV-480AS2B RAV-600FS8B/RAV-600AS8B

OWNER S AND INSTALLATION MANUAL RAV-480FS2B/RAV-480AS2B RAV-600FS8B/RAV-600AS8B OWNER S AND INSTALLATION MANUAL RAV-480FS2B/RAV-480AS2B RAV-600FS8B/RAV-600AS8B P/N: 52FS2B54070-R CONTENTS PRECAUTIONS Important Safety Information Hints For Economical Operation Standard Safety Instructions

More information

FLOOR-STANDING TYPE AIR CONDITIONER INSTALLATION MANUAL

FLOOR-STANDING TYPE AIR CONDITIONER INSTALLATION MANUAL FLOOR-STANDING TYPE AIR CONDITIONER INSTALLATION MANUAL CONTENTS SAFETY PRECAUTIONS Warning... Caution... INSTALLATION INSTRUCTIONS Accessories...;...3 Selecting installation place...4 PIPE CONNECTION

More information

Inverter Air Conditioner Installation Manual

Inverter Air Conditioner Installation Manual Inverter Air Conditioner Installation Manual KSV25CRG, KSV35CRG, KSV70CRG, KSV25HRG, KSD25HRG, KSV35HRG, KSD35HRG, KSV50HRG, KSD50HRG, KSV70HRG, KSD70HRG, KSV80HRG, KSD80HRG Congratulations Contents Congratulations

More information

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER Installation Manual IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make

More information

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL Split-type Air-Conditioner MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL Refer to the installation manual of each indoor unit for indoor unit installation. English Deutsch Français Nederlands Español Italiano

More information

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English Split-type Air-Conditioner MXZ-3B54VA MXZ-4B71VA INSTALLATION MANUAL English Refer to the installation manual of each indoor unit for indoor unit installation. IMPORTANT NOTES TO COMPLY WITH THE REQUIREMENTS

More information

Installation Instructions

Installation Instructions 40MHH High Wall Ductless System Sizes 09 to 24 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. NOTE: Images are for illustration purposes only. Actual

More information

HEAT PUMP INSTALLATION MANUAL

HEAT PUMP INSTALLATION MANUAL DUCTLESS INVERTER HEAT PUMP INSTALLATION MANUAL Models: TERRA09HP230V1A TERRA12HP230V1A TERRA18HP230V1B TERRA24HP230V1B Thank you for choosing a Gree Terra Ductless Heat Pump for your customer. Please

More information

VMH09/12/18/24 SU Series

VMH09/12/18/24 SU Series Installation and Operation Manual VMH09/12/18/24 SU Series Inverter Single Zone Ductless Mini-Split 517.787.2100 www.marsdelivers.com www.heatcontroller.com TABLE OF CONTENTS Safety Precautions Warnings

More information

[FLARE CONNECTION TYPE] ATTENTION

[FLARE CONNECTION TYPE] ATTENTION SPLIT-TYPE AIR CONDITIONERS Model MXZ-2A20NA [FLARE CONNECTION TYPE] HFC utilized R410A INSTALLATION MANUAL ATTENTION This manual mentions how to install only the outdoor unit, MXZ-2A20NA. As for the way

More information

Ductless Split Air Conditioner

Ductless Split Air Conditioner Ductless Split Air Conditioner Installation Manual Indoor HSU09VHG(DB)-W HSU12VHG(DB)-W HSU18VHH(DB)-W HSU24VHG(DB)-W Outdoor HSU09VHG(DB)-G HSU12VHG(DB)-G HSU18VHH(DB)-G HSU24VHG(DB)-G Table of Contents

More information

Split Air Conditioner

Split Air Conditioner Change for Life Split Air Conditioner Installation Manual Residential Air Conditioners MODEL: GWH09MA-A3DNXXA GWC09MA-A3DNXXA GWH12MB-A3DNXXA GWC12MB-A3DNXXA GWH09MB-D3DNXXD GWC09MB-D3DNXXD GWH12MB-D3DNXXD

More information

Installation Manual. Oasis Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

Installation Manual. Oasis Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS SPLIT-TYPE ROOM AIR CONDITIONER Installation Manual Oasis Series All Model Numbers CS78421-548-754 IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit.

More information

Fixed Speed Split Room Air Conditioner Installation Manual KSE26CRC, KSE26HRC, KSE35CRC, KSE35HRC, KSE53HRC, KSE62HRC, KSE70CRC, KSE70HRC, KSE88CRC

Fixed Speed Split Room Air Conditioner Installation Manual KSE26CRC, KSE26HRC, KSE35CRC, KSE35HRC, KSE53HRC, KSE62HRC, KSE70CRC, KSE70HRC, KSE88CRC Fixed Speed Split Room Air Conditioner Installation Manual KSE26CRC, KSE26HRC, KSE35CRC, KSE35HRC, KSE53HRC, KSE62HRC, KSE70CRC, KSE70HRC, KSE88CRC KSE88HRC Refrigerant R410A Congratulations Contents Congratulations

More information

DLCMRA. INSTALLATION INSTRUCTIONS Multi zone Outdoor Unit Ductless System Sizes 18, 27, 36 and 48 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

DLCMRA. INSTALLATION INSTRUCTIONS Multi zone Outdoor Unit Ductless System Sizes 18, 27, 36 and 48 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... DLCMRA INSTALLATION INSTRUCTIONS Multi zone Outdoor Unit Ductless System Sizes 18, 27, 36 and 48 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 GENERAL... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4

More information

Brivis. Ducted Reverse Cycle Inverter R410A INSTALLATION, START-UP, MAINTENANCE INSTRUCTIONS & USER OPERATING GUIDE

Brivis. Ducted Reverse Cycle Inverter R410A INSTALLATION, START-UP, MAINTENANCE INSTRUCTIONS & USER OPERATING GUIDE Brivis Ducted Reverse Cycle Inverter R410A INSTALLATION, START-UP, MAINTENANCE INSTRUCTIONS & USER OPERATING GUIDE PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLING & USING THIS PRODUCT Bonus

More information

INSTALLATION MANUAL. R410A Split Series. Model RXS24LVJU. Installation manual R410A Split series. Manual de instalación Serie Split R410A.

INSTALLATION MANUAL. R410A Split Series. Model RXS24LVJU. Installation manual R410A Split series. Manual de instalación Serie Split R410A. INSTALLATION MANUAL R410A Split Series Installation manual R410A Split series English Français Manual de instalación Serie Split R410A Español Model RXS24LVJU Safety Precautions Read these Safety Precautions

More information

Brivis Classic Ducted Gas Heater

Brivis Classic Ducted Gas Heater Brivis Classic Ducted Gas Heater Installer s Manual PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLING THIS PRODUCT Scope This Installer s Manual is intended to be used as a guideline for the installation

More information

Brivis Touch Controller. Installer Manual

Brivis Touch Controller. Installer Manual Brivis Touch Controller Installer Manual Brivis Touch Controller Kit Scope Please read these instructions carefully before installing this product. This manual covers the installation of the wall mounted

More information

MULTI TYPE ROOM AIR CONDITIONERS INSTALLATION INSTRUCTIONS

MULTI TYPE ROOM AIR CONDITIONERS INSTALLATION INSTRUCTIONS MULTI TYPE ROOM IR CONDITIONERS INSTLLTION INSTRUCTIONS Please read this instruction sheet completely before installing the product. When the power cord is damaged, replacement work shall be performed

More information

1. BEFORE INSTALLATION

1. BEFORE INSTALLATION ENGLISH SPLIT-TYPE AIR CONDITIONERS INSTALLATION MANUAL MSZ-D30/36NA MSY-D30/36NA JG79A061H01 Phillips screwdriver Level Scale Utility knife or scissors 3 in. (75 mm) hole saw Torque wrench Wrench (or

More information

AIR CONDITIONER CONSOLE

AIR CONDITIONER CONSOLE Installation manual ENGLISH AIR CONDITIONER CONSOLE English Indoor unit console type IT IS MANDATORY TO CUT OFF POWER SUPPLY BEFORE STARTING TO WORK IN THE ELECTRIC CASING BOXES. GENERAL RECOMMENDATIONS

More information

Notices for installation

Notices for installation Notices for installation Important Notices Before installing, please contact with local authorized maintenance center, if unit is not installed by the authorized maintenance center, the malfunction may

More information

FLOOR-STANDING SPLIT TYPE ROOM AIR CONDITIONER

FLOOR-STANDING SPLIT TYPE ROOM AIR CONDITIONER Before using your air conditioner, please read this manual carefully and keep it for future reference. FLOOR-STANDING SPLIT TYPE ROOM AIR CONDITIONER Please read this installation manual completely before

More information

Installation Instructions

Installation Instructions 38MGR Multi-zone Outdoor Unit Ductless System Sizes 18, 24, 30, 36 and 48 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 GENERAL... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS...

More information

Installation Instructions

Installation Instructions 38MPRA Outdoor Unit Single Zone Ductless System Sizes 09 to 12 Installation Instructions NOTES: Read the entire instruction manual before starting the installation. Images are for illustration purposes

More information

General safety precautions English

General safety precautions English English A min (m 2 ) 550 530 540 510 520 490 500 470 480 450 460 430 440 410 420 390 400 370 380 350 360 330 340 310 320 290 300 270 280 250 260 230 240 210 220 190 200 170 180 150 160 130 140 110 120

More information

General safety precautions English

General safety precautions English English A min (m 2 ) 550 530 540 510 520 490 500 470 480 450 460 430 440 410 420 390 400 370 380 350 360 330 340 310 320 290 300 270 280 250 260 230 240 210 220 190 200 170 180 150 160 130 140 110 120

More information

Installation Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Installation Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER Installation Manual IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make

More information

Safety Precautions (1)

Safety Precautions (1) 3P207257-3D M07B061D DAIKIN AIR CONDITIONER Two-dimensional bar code is a code for manufacturing. Safety Precautions (1) Read these Safety Precautions carefully to ensure correct installation. This manual

More information

INSTALLATION MANUAL. R410A Split Series. Models RXS15LVJU RXS18LVJU. Installation manual R410A Split series. Manuel dinstallation Série split R410A

INSTALLATION MANUAL. R410A Split Series. Models RXS15LVJU RXS18LVJU. Installation manual R410A Split series. Manuel dinstallation Série split R410A INSTALLATION MANUAL R410A Split Series Installation manual R410A Split series English Manuel dinstallation Série split R410A Français Manual de instalación Serie Split R410A Español Models RXS15LVJU RXS18LVJU

More information

Installation Instructions

Installation Instructions 40MAQ / 38MAQ 619PB / 538PR High---Wall Ductless Split System Sizes 09 to 30 Installation Instructions TABLE OF CONTENTS PAGE PARTS LIST... 2 SAFETY CONSIDERATIONS... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS...

More information

Table of Contents. Installation Manual. Accessories Safety Precautions Installation Overview Installation Diagram.

Table of Contents. Installation Manual. Accessories Safety Precautions Installation Overview Installation Diagram. Table of Contents Installation Manual 1 2 3 Accessories...04 Safety Precautions...05 Installation Overview...06 4 Installation Diagram...07 5 Specifications...08 6 Outdoor Unit Installation... 09 a. Outdoor

More information

Installation Instructions

Installation Instructions 38MGQ Multi-Zone Ductless System Sizes 18, 27, 36 and 48 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

More information

FOR SLIM DUCT/CEILING TYPE

FOR SLIM DUCT/CEILING TYPE INSTALLATION MANUAL AIR CONDITIONER FOR SLIM DUCT/CEILING TYPE For correct installation, read this manual before starting installation. This manual may be subject to change without notice for purpose of

More information

Inverter Air Conditioner Installation Manual

Inverter Air Conditioner Installation Manual Inverter Air Conditioner Installation Manual KSV25CRH, KSV35CRH, KSV71CRH, KSV25HRH, KSV35HRH, KSV50HRH, KSV71HRH, KSV90HRH, KSD25HRH, KSD35HRH, KSD50HRH, KSD71HRH, KSD90HRH Congratulations Contents Congratulations

More information

InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1

InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1 INSTALLATION, OPERATION & MAINTENANCE MANUAL InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1 Heat Controller 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100

More information

1. BEFORE INSTALLATION

1. BEFORE INSTALLATION ENGLISH SPLIT-TYPE AIR CONDITIONERS INSTALLATION MANUAL JG79A191H07 MSZ-GE06/09/12/15/18NA MSY-GE09/12/15/18NA When installing multi units, refer to the installation manual of the multi unit for outdoor

More information

Split-type Air-Conditioner

Split-type Air-Conditioner Split-type Air-Conditioner MXZ-2C52VA Installation Manual For INSTALLER This manual only describes the installation of outdoor unit. When installing the indoor unit, refer to the installation manual of

More information

Split-type Air-Conditioner

Split-type Air-Conditioner Split-type Air-Conditioner MXZ-2D52VA Installation Manual For INSTALLER This manual only describes the installation of outdoor unit. When installing the indoor unit, refer to the installation manual of

More information

Wall Air Handler Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual

Wall Air Handler Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual Presents Wall Air Handler Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual 615000156 REV B, 11/12/2018 2201 Dwyer Avenue, Utica, NY 13501 Tel. 800 253 7900 www.ecrinternational.com

More information