Water Pumps. turbo-hydraulic pumps, positive-displacement pumps.

Size: px
Start display at page:

Download "Water Pumps. turbo-hydraulic pumps, positive-displacement pumps."

Transcription

1 WATER PUMPS

2 Water Pumps Water pumps are devices designed to convert mechanical energy to hydraulic energy. All forms of water pumps may be classified into two basic categories: turbo-hydraulic pumps, positive-displacement pumps.

3 Turbo-hydraulic pumps are: centrifugal pumps, Propeller pumps, and jet pumps.

4 Analysis of turbo-hydraulic pumps: is a problem involving fundamental principles of hydraulics. Positive-displacement pumps: move fluid strictly by precise machine displacements such as a gear system rotating within a closed housing (screw pumps) or a piston moving in a sealed cylinder (reciprocal pumps).

5 Centrifugal Pumps Modern centrifugal pumps basically consist of two parts:- 1. the rotating element ( commonly called the impeller); 2. the housing that encloses the rotating element and seals the pressurized liquid inside. The power is supplied by a motor to the shaft of the impeller.

6 Cross section of a centrifugal pump

7

8

9

10 Jet (Mixed-Flow) Pumps

11 Pumps and Pumping Stations Pumps add energy to fluids and therefore are accounted for in the energy equation Energy required by the pump depends on: Discharge rate Resistance to flow (head that the pump must overcome) Pump efficiency (ratio of power entering fluid to power supplied to the pump) Efficiency of the drive (usually an electric motor) 2 2 v1 p1 v2 p2 z1 H pump z2 H 2g 2g L 2 H v L h f h h K minor f i 2 g

12 Pump Definition (Total) Static head difference in head between suction and discharge sides of pump in the absence of flow; equals difference in elevation of free surfaces of the fluid source and destination Static suction head head on suction side of pump in absence of flow, if pressure at that point is >0 Static discharge head head on discharge side of pump in absence of flow Static discharge head Total static head Static suction head

13 Pump Definition (Total) Static head difference in head between suction and discharge sides of pump in the absence of flow; equals difference in elevation of free surfaces of the fluid source and destination Static suction lift negative head on suction side of pump in absence of flow, if pressure at that point is <0 Static discharge head head on discharge side of pump in absence of flow Total static head Static discharge head Static suction lift

14 Pump Definition Static discharge head Total static head (both) Static suction head Static discharge head Static suction lift Total static head Static discharge head Static suction head Static discharge head Static suction lift Note: Suction and discharge head/ lift measured from pump centerline

15 Pump Definition (Total) Dynamic head, dynamic suction head or lift, and dynamic discharge head same as corresponding static heads, but for a given pumping scenario; includes frictional and minor headlosses Energy Line Total dynamic head Dynamic discharge head Dynamic suction lift

16 Example. Determine the static head, total dynamic head (TDH), and total headloss in the system shown below. El = 640 ft p s =6 psig El = 730 ft El = 630 ft p d =48 psig Total static head 730 ft 630 ft 100 ft 2.31 ft TDH 48 6 psi ft psi H TDH Static head ft 24.7 ft L

17 Example. A booster pumping station is being designed to transport water from an aqueduct to a water supply reservoir, as shown below. The maximum design flow is 25 mgd (38.68 ft 3 /s). Determine the required TDH, given the following: H-W C values are 120 on suction side and 145 on discharge side Minor loss coefficients are 0.50 for pipe entrance 0.18 for 45 o bend in a 48-in pipe 0.30 for 90 o bend in a 36-in pipe 0.16 and 0.35 for 30-in and 36-in butterfly valves, respectively Minor loss for an expansion is 0.25(v 2 2 v 12 )/2g El = 6127 to 6132 ft 30 to 48 expansion 8500of 36 pipe w/one 90 o bend and eight butterfly valves El = 6349 to 6357 ft Short 30 pipe w/30 butterfly valve 4000of 48 pipe w/two 45 o bends

18 1. Determine pipeline velocities from v = Q/A.. v 30 = 7.88 ft/s, v 36 = 5.47 ft/s, v 48 = 3.08 ft/s 2. Minor losses, suction side: 2 v30 Entrance: hl ft 2g 2 v30 Butterfly valve: hl ft 2g 2 2 v30 v 48 Expansion: hl ft 2g 2 o v 48 Two 45 bends: hl 2* ft 2g h L,minor 0.91 ft

19 3. Minor losses, discharge side: 2 v 36 8 Butterfly valves: hl 8* ft 2g 2 o v36 One 90 bend: hl ft 2g h L,minor 1.90 ft

20 4. Pipe friction losses: S h 1.85 f Q 2.63 L 0.43CD h f 1.85 Q L CD h f, suction ft /12 h f, discharge ft /12

21 5. Loss of velocity head at exit: Exit: h L v g 0.46 ft 6. Total static head under worst-case scenario (lowest water level in aqueduct, highest in reservoir): Static head ft 230 ft 7. Total dynamic head required: TDH H h h h static L, minor f L, exit ft ft

22 Pump Power P Q TDH CF E p P = Power supplied to the pump from the shaft; also called brake power (kw or hp) Q = Flow (m 3 /s or ft 3 /s) TDH = Total dynamic head = Specific wt. of fluid (9800 N/m 3 or 62.4 lb/ft 3 at 20 o C) CF = conversion factor: 1000 W/kW for SI, 550 (ft-lb/s)/hp for US E p = pump efficiency, dimensionless; accounts only for pump, not the drive unit (electric motor) Useful conversion: kw/hp

23 Example. Water is pumped 10 miles from a lake at elevation 100 ft to a reservoir at 230 ft. What is the monthly power cost at $0.08/kW-hr, assuming continuous pumping and given the following info: Diameter D = 48 in; Roughness e = ft, Efficiency P e =80% Flow = 25 mgd = ft 3 /s T = 60 o F Ignore minor losses El = 230 ft 2 El = 100 ft 1 10 mi of 48 pipe, e =0.003 ft 2 v1 2g p 1 2 v2 p2 z1 H pump 2g z2 HL H TDH z z H H h pump 2 1 stat L f TDH Hstat hf

24 El = 230 ft 2 El = 100 ft 1 10 mi of 48 pipe, e = ft TDH Hstat hf H ft 130 ft stat 2 L v hf f D 2 g v Q / A 3.08 ft/s Find f from Moody diagram 3.08 ft/s4 ft 6 vd Re 1.01x10 e D x10 ft /s ft 4 ft 7.5x10 4

25 El = 230 ft 2 10 mi of 48 pipe, El = 100 ft 1 e = ft 6 Re 1.01x10 e D 7.5x10 4 f

26 h f 2 10*5280 ft 3.08 ft/s ft 2 4 ft ft/s TDH H h ft ft stat f P ft /s ft 62.4 lb/ft Q TDH CF Ep ft-lb/s hp 918 hp kw $0.08 hr Daily cost 918 hp $1315 / d hp kw-hr d

27 Pump Selection System curve indicates TDH required as a function of Q for the given system For a given static head, TDH depends only on H L, which is approximately proportional to v 2 /2g Q is proportion to v, so H L is approximately proportional to Q 2 (or Q 1.85 if H-W eqn is used to model h f ) System curve is therefore approximately parabolic

28 Example. Generate the system curve for the pumping scenario shown below. The pump is close enough to the source reservoir that suction pipe friction can be ignored, but valves, fittings, and other sources of minor losses should be considered. On the discharge side, the 1000 ft of 16-in pipe connects the pump to the receiving reservoir. The flow is fully turbulent with D-W friction factor of Coefficients for minor losses are shown below. K values 40 ft 6 ft Suction Discharge

29 The sum of the K values for minor losses is 2.52 on the suction side and 5.52 on the discharge side. The total of minor headlosses is therefore 8.04 v 2 /2g. An additional 1.0 v 2 /2g of velocity head is lost when the water enters the receiving reservoir L v 1000 ft v v The frictional headloss is: hf f D 2 g 1.33 ft 2 g 2 g Total headloss is therefore ( )v 2 /2g = v 2 /2g. v can be written as Q/A, and A = pd 2 / 4 = 1.40 ft 2. The static head is 34 ft. So: 2 v TDH Hstat HL 34 ft g ft Q /1.40 ft 34 ft 0.19 s Q 2 ft ft/s 2

30 s TDH 34ft 0.19 Q ft 5 2 TDH (ft) System curve Static head Discharge, Q (ft 3 /s)

31 Pump Selection Pump curve indicates TDH provided by the pump as a function of Q; Depends on particular pump; info usually provided by manufacturer TDH at zero flow is called the shutoff head Pump efficiency Can be plotted as fcn(q), along with pump curve, on a single graph Typically drops fairly rapidly on either side of an optimum; flow at optimum efficiency known as normal or rated capacity Ideally, pump should be chosen so that operating point corresponds to nearly peak pump efficiency ( BEP, best efficiency point)

32 Pump Performance and Efficiency Curves Shutoff head Rated hp Rated capacity

33 Pump Efficiency Pump curves depend on pump geometry (impeller D) and speed

34 Pump Selection At any instant, a system has a single Q and a single TDH, so both curves must pass through that point; operating point is intersection of system and pump curves

35 Pump System Curve System curve may change over time, due to fluctuating reservoir levels, gradual changes in friction coefficients, or changed valve settings.

36 Pump Selection: Multiple Pumps Pumps often used in series or parallel to achieve desired pumping scenario In most cases, a backup pump must be provided to meet maximum flow conditions if one of the operating ( duty ) pumps is out of service. Pumps in series have the same Q, so if they are identical, they each impart the same TDH, and the total TDH is additive Pumps in parallel must operate against the same TDH, so if they are identical, they contribute equal Q, and the total Q is additive Adding a second pump moves the operating point up the system curve, but in different ways for series and parallel operation

37 Efficiency, % TDH (ft) Example. A pump station is to be designed for an ultimate Q of 1200 gpm at a TDH of 80 ft. At present, it must deliver 750 gpm at 60 ft. Two types of pump are available, with pump curves as shown. Select appropriate pumps and describe the operating strategy. How will the system operate under an interim condition when the requirement is for 600 gpm and 80-ft TDH? Pump B Pump A Flow rate (gpm)

38 Efficiency, % TDH (ft) Either type of pump can meet current needs (750 gpm at 60 ft); pump B will supply slightly more flow and head than needed, so a valve could be partially closed. Pump B has higher efficiency under these conditions, and so would be preferred Pump B Pump A Flow rate (gpm)

39 Efficiency, % TDH (ft) The pump characteristic curve for two type-b pumps in parallel can be drawn by taking the curve for one type-b pump, and doubling Q at each value of TDH. Such a scenario would meet the ultimate need (1200 gpm at 80 ft), as shown below Pump B Pump A Flow rate (gpm)

40 Efficiency, % TDH (ft) A pump characteristic curve for one type-a and one type-b pump in parallel can be drawn in the same way. This arrangement would also meet the ultimate demand. Note that the type-b pump provides no flow at TDH>113 ft, so at higher TDH, the composite curve is identical to that for just one type-a pump. (A check valve would prevent reverse flow through pump B.) Again, since type B is more efficient, two type-b pumps would be preferred over one type-a and one type-b One A and one B in parallel Pump B Pump A Flow rate (gpm)

41 Efficiency, % TDH (ft) At the interim conditions, a single type B pump would suffice. A third type B pump would be required as backup One A and one B in parallel Pump B Pump A Flow rate (gpm)

42 External Considerations External Conditions Hydraulic Operating Conditions Installation Practices Drive Train Flow Rate Piping Base Coupling Driver Pressure Configuration Size and Style Size and Style Size Turbulent Flow Alignment Grouting Alignment Speed Support

43 Cavitation in Water Pumps One of the important considerations in pump installation design is the relative elevation between the pump and the water surface in the supply reservoir. Whenever a pump is positioned above the supply reservoir, the water in the suction line is under pressure lower than atmospheric. The phenomenon of cavitation becomes a potential danger whenever the water pressure at any location in the pumping system drops substantially below atmospheric pressure. To make matters worse, water enters into the suction line through a strainer that is designed to keep out trash. This additional energy loss at the entrance reduces pressure even further.

44 A common site of cavitation is near the tips of the impeller vanes where the velocity is very high. In regions of high velocities much of the pressure energy is converted to kinetic energy. This is added to the elevation difference between the pump and the supply reservoir, hp, and to the inevitable energy loss in the pipeline between the reservoir and the pump, h L. Those three items all contribute to the total suction head, Hs, in a pumping installation

45 The value of Hs must be kept within a limit so that the pressure at every location in the pump is always above the vapor pressure of water; otherwise, the water will be vaporized and cavitation will occur. The vaporized water forms small vapor bubbles in the flow. These bubbles collapse when they reach the region of higher pressure in the pump. Violent vibrations may result from the collapse of vapor bubbles in water. Successive bubble breakup with considerable impact force may cause high local stresses on the metal surface of the vane blades and the housing. These stresses cause surface pitting and will rapidly damage the pump.

46 To prevent cavitation, the pump should be installed at an elevation so that the total suction head is less than the difference between the atmospheric head and the water vapor pressure head, or (Patm/ - Pvap/ ) > Hs

47

48 FAN AND BLOWER

49 Introduction Fan Components Provide air for ventilation and industrial processes that need air flow Outlet Diffusers Turning Vanes (typically used on short radius elbows) Baffles Heat Exchanger (US DOE, 1989) Filter Inlet Vanes Centrifugal Fan Belt Drive Motor Controller Variable Frequency Motor Drive 50 UNEP 2006

50 Introduction System Resistance Sum of static pressure losses in system Configuration of ducts, pickups, elbows Pressure drop across equipment Increases with square of air volume Long narrow ducts, many bends: more resistance Large ducts, few bends: less resistance 51 UNEP 2006

51 Introduction System Resistance System resistance curve for various flows Actual with system resistance calculated (US DOE, 1989) 52 UNEP 2006

52 Introduction Fan Curve Performance curve of fan under specific conditions Fan volume System static pressure Fan speed Brake horsepower (US DOE, 1989) 53 UNEP 2006

53 Introduction Operating Point Fan curve and system curve intersect Flow Q1 at pressure P1 and fan speed N1 Move to flow Q2 by closing damper (increase system resistance) (BEE India, Move to flow Q2 by reducing fan speed 54 UNEP 2006

54 Introduction Fan Laws (BEE India, 55 UNEP 2006

55 Types of Fans & Blowers Types of fans Centrifugal Axial Types of blowers Centrifugal Positive displacement 56 UNEP 2006

56 Types of Fans & Blowers Centrifugal Fans Rotating impeller increases air velocity Air speed is converted to pressure High pressures for harsh conditions High temperatures Moist/dirty air streams Material handling Categorized by blade shapes Radial Forward curved Backward inclined 57 UNEP 2006

57 Types of Fans & Blowers Centrifugal Fans Radial fans Advantages High pressure and temp Simple design High durability Efficiency up to 75% Large running clearances Disadvantages Suited for low/medium airflow rates only (Canadian Blower) 58 UNEP 2006

58 Types of Fans & Blowers Centrifugal Fans Forward curved Advantages Large air volumes against low pressure Relative small size Low noise level Disadvantages Not high pressure / harsh service Difficult to adjust fan output Careful driver selection Low energy efficiency 55-65% ( Canadian Blower) 59 UNEP 2006

59 Types of Fans & Blowers Centrifugal Fans - Backward-inclined Advantages Operates with changing static pressure Suited for high flow and forced draft services Efficiency >85% Disadvantages Not suited for dirty airstreams Instability and erosion risk ( Canadian Blower) 60 UNEP 2006

60 Types of Fans & Blowers Axial Fans Work like airplane propeller: Blades create aerodynamic lift Air is pressurized Air moves along fan axis Popular with industry: compact, low cost and light weight Applications Ventilation (requires reverse airflow) Exhausts (dust, smoke, steam) 61 UNEP 2006

61 Types of Fans & Blowers Axial Fans Propeller fans Advantages High airflow at low pressure Little ductwork Inexpensive Suited for rooftop ventilation Reverse flow Disadvantages Low energy efficiency Noisy (Fan air Company) 62 UNEP 2006

62 Types of Fans & Blowers Axial Fans Tube axial fans Advantages High pressures to overcome duct losses Suited for medium-pressure, high airflow rates Quick acceleration Space efficient Disadvantages Expensive Moderate noise Low energy efficiency 65% (Canadian Blower) 63 UNEP 2006

63 Types of Fans & Blowers Axial Fans Vane axial fans Advantages Suited for medium/high pressures Quick acceleration Suited for direct motor shaft connection Most energy efficient 85% Disadvantages Expensive (Canadian Blower) 64 UNEP 2006

64 Types of Fans & Blowers Blowers Difference with fans Much higher pressures <1.20 kg/cm2 Used to produce negative pressures for industrial vacuum systems Types Centrifugal blower Positive displacement 65 UNEP 2006

65 Types of Fans & Blowers Centrifugal Blowers Gear-driven impeller that accelerates air Single and multi-stage blowers Operate at kg/cm2 pressure Airflow drops if system pressure rises (Fan air Company) 66 UNEP 2006

66 Types of Fans & Blowers Positive Displacement Blowers Rotors trap air and push it through housing Constant air volume regardless of system pressure Suited for applications prone to clogging Turn slower than centrifugal blowers Belt-driven for speed changes 67 UNEP 2006

67 Assessment of fans and blowers Fan Efficiency and Performance Fan efficiency: Ratio of the power conveyed to air stream and power delivered by the motor to the fan Depends on type of fan and impeller Fan performance curve Graph of different pressures and corresponding required power Supplier by manufacturers 68 UNEP 2006

68 Efficiency Assessment of fans and blowers Peak efficiency or Best Efficiency Point (BEP) Backward Airfoil Type of Fan Peak Efficiency Range Radial Centrifugal fans: Airfoil, Backward curved/inclined Modified radial Tubular Radial Pressure blower Forward curved (BEE India, 2004) Forward Flow rate Axial fans: Vane axial Tube axial Propeller UNEP

69 Assessment of fans and blowers Methodology fan efficiency Before calculating fan efficiency Measure operating parameters Air velocity, pressure head, air stream temp, electrical motor input Ensure that Fan is operating at rated speed Operations are at stable condition 70 UNEP 2006

70 Assessment of fans and blowers Methodology fan efficiency Step 1: Calculate air/gas density t = Temperature of air/gas at site condition Step 2: Measure air velocity and calculate average Cp = Pitot tube constant, 0.85 (or) as given by the manufacturer p = Average differential pressure γ = Density of air or gas at test condition Step 3: Calculate the volumetric flow in the duct 71 UNEP 2006

71 Assessment of fans and blowers Methodology fan efficiency Step 4: Measure the power drive of the motor Step 5: Calculate fan efficiency Fan mechanical efficiency Fan static efficiency 72 UNEP 2006

72 Assessment of fans and blowers Difficulties in Performance Assessment Non-availability of fan specification data Difficulty in velocity measurement Improper calibration of instruments Variation of process parameters during tests 73 UNEP 2006

73 Energy Efficiency Opportunities 1. Choose the right fan 2. Reduce the system resistance 3. Operate close to BEP 4. Maintain fans regularly 5. Control the fan air flow 74 UNEP 2006

74 Energy Efficiency Opportunities 1. Choose the Right Fan Considerations for fan selection Noise Rotational speed Air stream characteristics Temperature range Variations in operating conditions Space constraints and system layout Purchase/operating costs and operating life Systems approach most important! 75 UNEP 2006

75 Energy Efficiency Opportunities 1. Choose the Right Fan Avoid buying oversized fans Do not operate at Best Efficiency Point Risk of unstable operation Excess flow energy High airflow noise Stress on fan and system 76 UNEP 2006

76 Energy Efficiency Opportunities 2. Reduce the System Resistance Increased system resistance reduces fan efficiency Check periodically Check after system modifications Reduce where possible (BEE India, 2004) 77 UNEP 2006

77 Energy Efficiency Opportunities 3. Operate Close to BEP Best Efficiency Point = maximum efficiency Normally close to rated fan capacity Deviation from BEP results in inefficiency and energy loss 78 UNEP 2006

78 Energy Efficiency Opportunities 4. Maintain Fans Regularly Periodic inspection of all system components Bearing lubrication and replacement Belt tightening and replacement Motor repair or replacement Fan cleaning 79 UNEP 2006

79 Energy Efficiency Opportunities 5. Control the Fan Air flow a) Pulley change b) Dampers c) Inlet guide vanes d) Variable pitch fans e) Variable speed drives (VSD) f) Multiple speed drive g) Disc throttle h) Operating fans in parallel i) Operating fans in series 80 UNEP 2006

Ducted Propeller. Airflow Volume

Ducted Propeller. Airflow Volume Total Pressure Radial-Blade Centrifugal Tubeaxial Backward-inclined Airfoil Centrifugal Forward-curved Centrifugal Ducted Propeller Airflow Volume Figure 2: Forward-Curved Centrifugal Fan

More information

Introduction to Fans. The Basics of Fan Principles and Terminology

Introduction to Fans. The Basics of Fan Principles and Terminology Introduction to Fans The Basics of Fan Principles and Terminology Airflow Principles A fan is a rotating device that creates pressure differential that results in air movement Pressure rise in a fan Downstream

More information

Rotodynamic Pumps INTRODUCTION:

Rotodynamic Pumps INTRODUCTION: Rotodynamic Pumps INTRODUCTION: Liquids have to be moved from one location to another and one level to another in domestic, agricultural and industrial spheres. The liquid is more often water in the domestic

More information

CENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components:

CENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components: Pumps DOE-HDBK-1018/1-93 CENTRIFUGAL PUMPS CENTRIFUGAL PUMPS Centrifugal pumps are the most common type of pumps found in DOE facilities. Centrifugal pumps enjoy widespread application partly due to their

More information

Selecting the Correct Fan

Selecting the Correct Fan Selecting the Correct Fan Ryan B. Johnson Air Purification Company Sales Engineer Member, ASHRAE Pikes Peak Chapter rjohnson@airpurificationcompany.com 1 Your Speaker circa 1998 Fan Types Applications

More information

FAN TYPES CENTRIFUGAL FAN Forward Curve Centrifugal Fan

FAN TYPES CENTRIFUGAL FAN Forward Curve Centrifugal Fan FAN TYPES In order to cover a wide range of applications, fans are manufactured in a variety of type. They can be classified under three general types : (a) Centrifugal, (b) Axial and (c) Mixed flow. Table

More information

Fan Selection. and Energy Savings

Fan Selection. and Energy Savings Fan Selection and Energy Savings Reducing power consumption by minimizing system pressure loss and choosing the right equipment HBy BRIAN MLEZIVA Greenheck Fan Corp. Schofield, Wis. Power Consumption HVAC

More information

Fan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10

Fan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10 Fan Laws Keith Miller Samuel Tepp Associates Paul Cenci, P. E.-Principal Brian England-Principal Basic Terms CFM - Cubic Feet per Minute, volume (amount) of air being moved SP - Static Pressure, resistance

More information

Fan Performance and Selection. Overview

Fan Performance and Selection. Overview Fan Performance and Selection References Burmeister, L.C., Elements of Thermal-Fluid System Design, Prentice Hall, 1998. ASHRAE Handbook: HVAC Systems and Equipment, 1992. Overview Common fan types: centrifugal

More information

1900 Series In-Line Pump

1900 Series In-Line Pump Water Circulation Pumps & Circulators 1900 Series In-Line Pump HYDRONIC COMPONENTS & SYSTEMS Taco Catalog #: 300-1.4 Supersedes: 300-1.4 Dated: 06/15/95 Effective Date: 03/15/05 Printed in USA 2. Features

More information

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans PARAG FANS & COOLING SYSTEMS LTD. Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans Registered Office & Works Plot No.1/2B & 1B/3A, Industrial Area No.1 A.B.Road, Dewas 455001 (M.P.)

More information

Agitation and Mixing

Agitation and Mixing Agitation and Mixing Agitation: Agitation refers to the induced motion of a material in a specified way, usually in a circulatory pattern inside some sort of container. Purpose is to make homogeneous phase.

More information

Condenser Water Pump Calculator Guide

Condenser Water Pump Calculator Guide Condenser Water Pump Calculator Guide Table of Contents 1.0 Introduction... 3 1.1 Units... 3 2.0 Disclaimer... 3 3.0 Overall Condenser Water System... 3 4.0 Condenser Water Pump Calculator - Inputs...

More information

Fans: Features and Analysis

Fans: Features and Analysis Technical Development Program COMMERCIAL HVAC EQUIPMENT Fans: Features and Analysis PRESENTED BY: Michael Ho Version 1.2 Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Section

More information

FANS & BLOWERS ENERGY EFFICIENCY REFERENCE GUIDE TRAINING & SUPPORT

FANS & BLOWERS ENERGY EFFICIENCY REFERENCE GUIDE TRAINING & SUPPORT FANS & BLOWERS ENERGY EFFICIENCY REFERENCE GUIDE TRAINING & SUPPORT Disclaimer: Neither CEATI International, the authors, nor any of the organizations providing funding support for this work (including

More information

PEMP RMD M.S. Ramaiah School of Advanced Studies

PEMP RMD M.S. Ramaiah School of Advanced Studies Hydraulic Pumps Session delivered by: Prof. Q.H. Nagpurwala 1 Session Objectives This session is intended to discuss and understand the following: Classification of hydraulic pumps Construction and working

More information

AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS

AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS FPAC FPMC FPDA CATALOG AX351 JULY 2001 WWW.TCF.COM

More information

The Advantages of Choosing Centrifugal Fans

The Advantages of Choosing Centrifugal Fans The Advantages of Choosing Centrifugal Fans Introduction Centrifugal fans are widely used for various commercial and industrial applications today. These fans are popular choices for automotive, heating,

More information

Pumps for Florida Irrigation and Drainage Systems 1

Pumps for Florida Irrigation and Drainage Systems 1 CIR832 1 Dorota Z. Haman 2 The primary function of a pump is to transfer energy from a power source to a fluid, and as a result to create flow, lift, or greater pressure on the fluid. A pump can impart

More information

Pumps SELECTION OF A PUMP

Pumps SELECTION OF A PUMP Pumps SELECTION OF A PUMP A water system needs to move the water produced from the source to its customers. In almost all cases in Minnesota, the source is at a lower elevation than the user so the water

More information

Water engineers and utilities are often

Water engineers and utilities are often FWRJ Horizontal or Vertical? High-Service Pump Selection Mark Ludwigson, Len Rago, and Jeff Greenfield Water engineers and utilities are often faced with a decision concerning the best type of pump when

More information

Selecting Fans and Determining Airflow for Grain Drying and Storage

Selecting Fans and Determining Airflow for Grain Drying and Storage Proceedings of the Integrated Crop Management Conference Proceedings of the 1993 Integrated Crop Management Conference Dec 2nd, 12:00 AM Selecting Fans and Determining Airflow for Grain Drying and Storage

More information

FAN ENGINEERING. Surge, Stall and Instabilities in Fans

FAN ENGINEERING. Surge, Stall and Instabilities in Fans FAN ENGINEERING Industrial Fans & Services Information and Recommendations for the Engineer Surge, Stall and Instabilities in Fans Introduction Users of fan systems would like to experience a steady, continuous

More information

Boiler Draft Equipment

Boiler Draft Equipment Boiler Draft Equipment Learning Outcome When you complete this module you will be able to: Discuss, sketch and describe the basic equipment used to supply combustion air to a boiler furnace. Learning Objectives

More information

COMMERCIAL HVAC AIR-HANDLING EQUIPMENT. Fans in VAV Systems

COMMERCIAL HVAC AIR-HANDLING EQUIPMENT. Fans in VAV Systems COMMERCIAL HVAC AIR-HANDLING EQUIPMENT Fans in VAV Systems Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application topics.

More information

GT Series Single-Stage, Double Suction Horizontal Split Case Pumps

GT Series Single-Stage, Double Suction Horizontal Split Case Pumps Water Circulation Pumps & Circulators GT Series Single-Stage, Double Suction Horizontal Split Case Pumps GT Series Pumps provide the ultimate in reliability and ease of installation for heating, air conditioning,

More information

What is the correct type of fan: Axial, radial, diagonal?

What is the correct type of fan: Axial, radial, diagonal? Press News The theory and practice of small fans (1) What is the correct type of fan: Axial, radial, diagonal? Fans are as varied in their construction as they are in their applications. These "air-donors"

More information

Rich Knoelke. Questions or Comments: Mulcahy Shaw Water.

Rich Knoelke. Questions or Comments: Mulcahy Shaw Water. Rich Knoelke Mulcahy Shaw Water Questions or Comments: rknoelke@mulcahyshaw.com CASE STUDY LaCrosse WI WWTP Four New Turbo Blowers New Diffusers with Tapered Layout DO Control System Automated Air Valves

More information

FANS & BLOWERS. Energy Efficiency Reference Guide. Airflow Volume. Ducted Propeller

FANS & BLOWERS. Energy Efficiency Reference Guide. Airflow Volume. Ducted Propeller Total Pressure FANS & BLOWERS Energy Efficiency Reference Guide Radial-Blade Centrifugal Tubeaxial Backward-inclined Airfoil Centrifugal Forward-curved Centrifugal Ducted Propeller Airflow Volume DISCLAIMER:

More information

PUMPS FOR LIVESTOCK WATERING SYSTEMS. This Factsheet outlines the design and operation of pumps that are suited for livestock watering systems.

PUMPS FOR LIVESTOCK WATERING SYSTEMS. This Factsheet outlines the design and operation of pumps that are suited for livestock watering systems. Livestock Watering Order No. 590.305-2 January 2006 PUMPS FOR LIVESTOCK WATERING SYSTEMS This Factsheet outlines the design and operation of pumps that are suited for livestock watering systems. Introduction

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 230593 - TESTING, ADJUSTING, AND BALANCING FOR HVAC PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Balancing Air Systems: a. Constant-volume air systems. b. Variable-air-volume systems. 2.

More information

WHY SULLAIR? For more information on the IHI-Sullair joint venture, please visit 2,000th IHI-Sullair centrifugal

WHY SULLAIR? For more information on the IHI-Sullair joint venture, please visit   2,000th IHI-Sullair centrifugal WHY SULLAIR? Since 2004 Sullair has been part of IHI-Sullair, a joint venture focused on developing and producing high performance centrifugal compressors. Those compressor models, with more than a decade

More information

Selection and Operational Considerations. Harold Streicher, Vice President Sales Hansen Technologies, Inc.

Selection and Operational Considerations. Harold Streicher, Vice President Sales Hansen Technologies, Inc. Selection and Operational Considerations Harold Streicher, Vice President Sales Hansen Technologies, Inc. Introduction to liquid refrigerant pumps Open Drive and Semi-Hermetic (sealless) centrifugal pumps

More information

Irrigation Water Pumps

Irrigation Water Pumps AE1057 (Revised) Irrigation Water Pumps The heart of most irrigation systems is a pump. To make an irrigation system as efficient as possible, the pump must be selected to match the requirements of the

More information

Vacuum System Troubleshooting Author: Keith Webb, P.E. Application Engineering Manager

Vacuum System Troubleshooting Author: Keith Webb, P.E. Application Engineering Manager INTRODUCTION The science of creating vacuum is often misunderstood and when the desired vacuum condition is not being achieved in a manufacturing setting this usually means production comes to a halt and

More information

HVAC Pumps Characteristics and Energy Efficiency

HVAC Pumps Characteristics and Energy Efficiency PDHonline Course M329 (5 PDH) HVAC Pumps Characteristics and Energy Efficiency Instructor: A. Bhatia, B.E. 2012 PDH Online PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone & Fax: 703-988-0088

More information

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP DS series Industrial End Suction Pumps ISO/DP 5199 www.sterlingpumps.com.au DS series Capacities from: Heads from: 340 to 5,680 m3/h (1,500 to 25,000 USPGM) 21 to 106 metres (70 to 350 feet) Power range

More information

Off Design Operation of Hybrid Noncondensable Gas Removal Systems for Flash Steam Cycle Geothermal Power Plants

Off Design Operation of Hybrid Noncondensable Gas Removal Systems for Flash Steam Cycle Geothermal Power Plants GRC Transactions, Vol. 40, 2016 Off Design Operation of Hybrid Noncondensable Gas Removal Systems for Flash Steam Cycle Geothermal Power Plants Jason Project Engineer, Vooner FloGard Corporation, Charlotte

More information

MCH Series Drives. HVAC Application Guide. ag-mch-e2

MCH Series Drives. HVAC Application Guide. ag-mch-e2 Drives HVAC Application Guide ag-mch-e2 % Flow, Torque, HP AFFINITY LAWS Most HVAC systems are designed to perform during peak load conditions that rarely occur during the year. Various flow control methods

More information

POWERENERGY

POWERENERGY ASME 2016 POWER CONFERENCE JUNE 26 JUNE 30, 2016 CHARLOTTE, NORTH CAROLINA, USA POWERENERGY2016-59067 EVACUATION SYSTEMS FOR STEAM SURFACE CONDENSERS: VACUUM PUMPS OR STEAM JET AIR EJECTORS? Ranga Nadig,

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 23 0594 - TESTING, ADJUSTING, AND BALANCING (TAB) PART 1 - GENERAL 1.1 SUMMARY A. This Section includes testing, adjusting and balancing HVAC systems to provide design conditions as indicated by

More information

Glossary of Terms Laboratory & Fume Exhaust Fans

Glossary of Terms Laboratory & Fume Exhaust Fans Glossary of Terms Laboratory & Fume Exhaust Fans ACTUATOR, 2-POSITION SPRING RETURN A spring return actuator generally used to control the isolation dampers below the fans. This actuator allows for fully

More information

Pumps CEU 259. Continuing Education from the American Society of Plumbing Engineers. May ASPE.ORG/ReadLearnEarn

Pumps CEU 259. Continuing Education from the American Society of Plumbing Engineers. May ASPE.ORG/ReadLearnEarn Pumps Continuing Education from the American Society of Plumbing Engineers May 2018 ASPE.ORG/ReadLearnEarn CEU 259 READ, LEARN, EARN Note: In determining your answers to the CE questions, use only the

More information

Effects of Volute Tongue Clearance and Rotational Speed on Performance of Centrifugal Blower Nitin S. Jadhav *, S. R. Patil

Effects of Volute Tongue Clearance and Rotational Speed on Performance of Centrifugal Blower Nitin S. Jadhav *, S. R. Patil 2016 IJSRSET Volume 2 Issue 4 Print ISSN : 2395-1990 Online ISSN : 2394-4099 Themed Section: Engineering and Technology Effects of Volute Tongue Clearance and Rotational Speed on Performance of Centrifugal

More information

Centrifugal and Positive Displacement Pumps for Hygienic Applications

Centrifugal and Positive Displacement Pumps for Hygienic Applications Centrifugal and Positive Displacement Pumps for Hygienic Applications ISPE Meeting November 18, 2008 Presented by: Allen E. LeBoeuf, Product Manager Oliver M. Dean, Inc. Worcester, MA Primary Issues: Selection

More information

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING TM MITTAL ENGINEERING M i t t a l E n g i n e e r i n g i s o n e o f t h e l e a d i n g m a n u f a c t u r e r s q u a l i t y e n g i n e e r i n g

More information

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) www.blowtech.in we make air move Blowtech Air Devices Pvt. Ltd. was founded in 1988 and quickly established

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN AX351 July 2001 AXICO ANTI-STALL Controllable Pitch-In-Motion and Adjustable Pitch-At-Rest Vaneaxial Fans Types FPAC, FPMC, FPDA A complete product bulletin including performance

More information

KV Vertical Inline Pumps Taco Vertical Inline Pumps meet the latest standards for hydraulic performance and dimensional

KV Vertical Inline Pumps Taco Vertical Inline Pumps meet the latest standards for hydraulic performance and dimensional Water Circulation Pumps & Circulators KV Vertical Inline Pumps Taco Vertical Inline Pumps meet the latest standards for hydraulic performance and dimensional characteristics. H ydronic C omponents & S

More information

EXPERIMENTAL ACOUSTIC CHARACTERIZATION OF A WET VACUUM CLEANER

EXPERIMENTAL ACOUSTIC CHARACTERIZATION OF A WET VACUUM CLEANER EXPERIMENTAL ACOUSTIC CHARACTERIZATION OF A WET VACUUM CLEANER Cinzia Buratti, Elisa Moretti and Michele Urbani Department of Industrial Engineering, University of Perugia, via G. Duranti 67, 06125 Perugia,

More information

ENGINEERING LETTER 4

ENGINEERING LETTER 4 ENGINEERING LETTER 4 The New York Blower Company 7660 Quincy Street, Willowbrook, Illinois 60521-5530 TEMPERATURE AND ALTITUDE AFFECT FAN SELECTION INTRODUCTION Fan performance changes with the density

More information

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS MCF 00 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS MCF 00 CENTRIFUGAL FAN FOR COMBUSTIBLE GASES MCF 00 centrifugal fan for biogas, natural gas or combustible gases, in conformity to the

More information

Modern vacuum and overpressure generation for pneumatic conveying

Modern vacuum and overpressure generation for pneumatic conveying Modern vacuum and overpressure generation for pneumatic conveying Bernd Jack Dr.-Ing. K. Busch GmbH Contents 1. General 3 2. Fields of application 4 3. Description of vacuum 5 and overpressure generators

More information

Monitoring Pump Performance with Vibration. Mitchell Stansloski, PhD, PE

Monitoring Pump Performance with Vibration. Mitchell Stansloski, PhD, PE Monitoring Pump Performance with Vibration Mitchell Stansloski, PhD, PE Centrifugal Pumps Centrifugal pumps Centrifugal Pumps (Radial Flow Pumps): A pump using radial flow impellers that give their energy

More information

Chapter 4 Compressors Overview & System Annual Power Consumption

Chapter 4 Compressors Overview & System Annual Power Consumption Chapter 4 Compressors Overview & System Annual Power Consumption Copy Right By: Thomas T.S. Wan 温 Sept. 3, 2008 All rights reserved (Cor. 07-08-12) Compressor is the heart of the refrigeration system.

More information

Main Characteristics of Appliances for Transport and Compression of Air

Main Characteristics of Appliances for Transport and Compression of Air Ing. Pavel Dostál, Ph.D., Ostrava University 1 Main Characteristics of Appliances for Transport and Compression of Air Some of the main technical characteristics of appliances for the transport and compression

More information

Energy Guide. Fan Efficiency Grades. FEG Ratings. July

Energy Guide. Fan Efficiency Grades. FEG Ratings. July Energy Guide Fan Efficiency Grades s July 2013 Certified Fans Location Mounting Airflow Application Drive Type Impeller Type Performance Model Outdoor Indoor Roof Curb Base/Floor Hanging Wall Ceiling Mounted

More information

PDHonline Course M140 (3 PDH) Pumps. Instructor: Lawrence J. Marchetti, P.E. PDH Online PDH Center

PDHonline Course M140 (3 PDH) Pumps. Instructor: Lawrence J. Marchetti, P.E. PDH Online PDH Center PDHonline Course M140 (3 PDH) Pumps Instructor: Lawrence J. Marchetti, P.E. 2012 PDH Online PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone & Fax: 703-988-0088 www.pdhonline.org www.pdhcenter.com

More information

FI / SFI Frame-Mounted End Suction Pumps

FI / SFI Frame-Mounted End Suction Pumps Water Circulation Pumps & Circulators FI / SFI Frame-Mounted End Suction Pumps FI Series Pumps provide the ultimate in reliability and ease of installation for heating, air conditioning, pressure boosting,

More information

BRINE CIRCULATED ICE THERMAL STORAGE SYSTEM DESIGN - CASE ILLUSTRATION - Partial Ice Storage for Air Conditioning Application

BRINE CIRCULATED ICE THERMAL STORAGE SYSTEM DESIGN - CASE ILLUSTRATION - Partial Ice Storage for Air Conditioning Application 1 BRINE CIRCULATED ICE THERMAL STORAGE SYSTEM DESIGN - CASE ILLUSTRATION - Partial Ice Storage for Air Conditioning Application By: T. S. Wan Date: Oct. 7, 1995 Copy Right 1995 by T. S. Wan All rights

More information

Understanding Process Vacuum for Process Improvement

Understanding Process Vacuum for Process Improvement Understanding Process Vacuum for Process Improvement Through this article we wish to give practical tips to boost process capacity, increase product quality and reduce cycle time in batch or continuous

More information

1. Know your process. The following guidelines will help you navigate what can be a challenging and time consuming task.

1. Know your process. The following guidelines will help you navigate what can be a challenging and time consuming task. Many processes today require an indirect method of heating, which implies the use of a heat transfer medium, instead of circulating the process directly into a heater. Thermal oil, water, glycol mixtures,

More information

SSRG International Journal of Thermal Engineering (SSRG-IJTE) volume 1 Issue1 Jan to April 2015

SSRG International Journal of Thermal Engineering (SSRG-IJTE) volume 1 Issue1 Jan to April 2015 Time Domain Sound Spectrum Measurements in Ducted Axial Fan under Stall Region Dr.S.Divya Sree, B.Yuvan Asst. Prof., M.Tech Student, Thermal Engineering, University of Calicut ABSTRACT: An axial fan is

More information

Multistage Centrifugal Blowers

Multistage Centrifugal Blowers Multistage Centrifugal Blowers Multistage Centrifugal Blowers In order to meet all the requirements for air and gas applications, Ingersoll Rand provides a new generation of Hibon Multistage Centrifugal

More information

DAE Systems. Fan Selection Guide. Section 1: Terminology

DAE Systems. Fan Selection Guide. Section 1: Terminology DAE Systems Fan Selection Guide Section 1: Terminology CFM : Cubic Feet per Minute Technical Terms This refers to the amount of air a fan is able to move. Pressure Inches of water is a common method of

More information

Australian Journal of Basic and Applied Sciences

Australian Journal of Basic and Applied Sciences AENSI Journals Australian Journal of Basic and Applied Sciences ISSN:1991-8178 Journal home page: www.ajbasweb.com Design and Experimental Investigation of Forward Curved, Backward Curved and Radial Blade

More information

Varofoil Controllable Pitch in Motion Fans Compared to Variable Frequency Controlled Fans

Varofoil Controllable Pitch in Motion Fans Compared to Variable Frequency Controlled Fans Varofoil Controllable Pitch in Motion Fans Compared to Variable Frequency Controlled Fans A look at two accepted technologies.. System Characteristics In general, the pressure developed by a fan is a function

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

College of Technological Studies Department of Power & Refrigeration Technology. Course Contents

College of Technological Studies Department of Power & Refrigeration Technology. Course Contents College of Technological Studies Department of Power & Refrigeration Technology Course Contents Course Designation: Air Conditioning Control systems Course No. : 272 0463 Credit Hrs.: 3 Lecture Hrs.: 2

More information

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide 1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide Installation Location! The pump should be located as close as possible to the liquid source so that the suction line can be as short and direct

More information

MODEL ANSWER PAPER. Vertical Slurry Pumps can be subdivided into two main groups:

MODEL ANSWER PAPER. Vertical Slurry Pumps can be subdivided into two main groups: SHEKHAWATI INST. OF ENG.& TECHNOLOGY COLLEGE SIKAR, RAJASTHAN 1 st MID TERM EXAMINATION 2017-18 (B.TECH 3 rd year - MI) Subject Code & Name: 6MI4 MINE MACHINERY II MM: 20 Time: 1.5hrs MODEL ANSWER PAPER

More information

SECTION STEAM CONDENSATE PUMPS

SECTION STEAM CONDENSATE PUMPS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 22 23 STEAM CONDENSATE PUMPS SPEC WRITER NOTES: 1. Delete between // ---- // if not applicable to project. Also delete any other item or paragraph not applicable

More information

FAN PERFORMANCE AND UTILIZATION OF COMPRESSED AIR IN THERMALPOWERPLANT

FAN PERFORMANCE AND UTILIZATION OF COMPRESSED AIR IN THERMALPOWERPLANT FAN PERFORMANCE AND UTILIZATION OF COMPRESSED AIR IN THERMALPOWERPLANT V Hari Kiran 1, K Uday Kiran Kumar 2, M M Praveen Kumar 3 1 Asst.Proffessor, Avanthi Institute Of Engineering And Technology, Makavaripalem,

More information

A. Codes and Standards that are Standard at the University:

A. Codes and Standards that are Standard at the University: PART 1: GENERAL 1.01 Purpose: 1.02 References: 1.03 Requirements: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 233423 - HVAC POWER VENTILATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 PERFORMANCE REQUIREMENTS A. Operating

More information

Manhardt Lindel / ERHARD-Armaturen VALVE & PIPELINE CAVITATION

Manhardt Lindel / ERHARD-Armaturen VALVE & PIPELINE CAVITATION Manhardt Lindel / ERHARD-Armaturen VALVE & PIPELINE CAVITATION What is cavitation? Cavitation is a physical process, which can arise in liquids. It describes the phase transition between the liquid and

More information

Blowers. Side channel compressors and vacuum pumps. Your Choice, Our Commitment

Blowers. Side channel compressors and vacuum pumps. Your Choice, Our Commitment Blowers Side channel compressors and vacuum pumps Your Choice, Our Commitment 02 Solutions for Water & Industry SEKO's range of side channel blowers are an effective solution to for air displacement in

More information

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004) High Plume Blowers Suggested Specification Section 15500 (Master Format 1996) Suggested Specification Section 23 38 16 (Master Format 2004) PART 1 GENERAL 1.01 WORK INCLUDED High Plume Laboratory Exhaust

More information

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Construction Standards Page 233423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified

More information

PIPING SYSTEM EQUIPMENTS

PIPING SYSTEM EQUIPMENTS PIPING SYSTEM EQUIPMENTS Introduction Equipments are devices that provide power, process and store materials. Equipments in piping systems depend on the specific industries using them. Specialized equipment

More information

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities Pulse Jet ASTEC PULSE JET BAGHOUSE for Asphalt Facilities ASTEC PULSE JET BAGHOUSE FOR ASPHALT MIXING PLANTS Astec baghouses deliver superior performance and efficiency, while helping your plant meet

More information

Multistage Centrifugal Blowers

Multistage Centrifugal Blowers Multistage Centrifugal Blowers Multistage Centrifugal Blowers In order to meet all the requirements for air and gas applications, Ingersoll Rand provides a new generation of Hibon Multistage Centrifugal

More information

PREVIEW COPY. Compressors. Table of Contents. Introduction to Compressors...3. Lesson Two Reciprocating Compressors...21

PREVIEW COPY. Compressors. Table of Contents. Introduction to Compressors...3. Lesson Two Reciprocating Compressors...21 Compressors Table of Contents Lesson One Introduction to Compressors...3 Lesson Two Reciprocating Compressors...21 Lesson Three Rotary, Helical, and Scroll Compressors...37 Lesson Four Centrifugal Compressors...51

More information

Proposal Information Template Commercial and Industrial Fans and Blowers 2017 Appliance Efficiency Standards

Proposal Information Template Commercial and Industrial Fans and Blowers 2017 Appliance Efficiency Standards Proposal Information Template 2017 Appliance Efficiency Standards Appliance Standards Awareness Project (ASAP), Northwest Energy Efficiency Alliance (NEEA), Natural Resources Defense Council (NRDC), American

More information

HVAC Clinic. Helical Rotary & Centrifugal Water Chillers

HVAC Clinic. Helical Rotary & Centrifugal Water Chillers HVAC Clinic Helical Rotary & Centrifugal Water Chillers Table Of Contents Introduction... 3 Chiller Types... 3 Chiller Components... 4 Refrigeration Cycle... 15 Application Considerations... 19 Introduction

More information

Turbo-blowers and Turbo-compressors

Turbo-blowers and Turbo-compressors Ing. Pavel Dostál, Ph.D., Ostrava University 1 Turbo-blowers and Turbo-compressors Turbo-blowers are rotational radial blade appliances without external intercoolers instrumental to the transport and compression

More information

Drive Power and Torque in Paper Machine Dryers

Drive Power and Torque in Paper Machine Dryers Drive Power and Torque in Paper Machine Dryers 2 nd Edition Gregory L. Wedel President Kadant Johnson Inc. Gerald L. Timm Vice President, Research & Development Kadant Johnson Inc. Technical White Paper

More information

Custom Design TYPE CS

Custom Design TYPE CS SHIPPENSBURG PUMP CO., INC. P.O. BOX 279, SHIPPENSBURG, PA 17257 PHONE 717-532-7321 FAX 717-532-7704 WWW.SHIPCOPUMPS.COM BULLETIN 109 Revised 3/05 Custom Design TYPE CS Cylindrical Steel Boiler Feed Pumps

More information

INSTALLATION MANUAL FOR ROTARY TWIN LOBE (ROOTS) BLOWERS / COMPRESSORS

INSTALLATION MANUAL FOR ROTARY TWIN LOBE (ROOTS) BLOWERS / COMPRESSORS INSTALLATION MANUAL FOR ROTARY TWIN LOBE (ROOTS) BLOWERS / COMPRESSORS AIRVAC INDUSTRIES & PROJECTS CORPORATE OFFICE: H-2/111, SECTOR-16, ROHINI, DELHI-110 085 PHONE: +91-11-32958731, 27298061 FAX: +91-11-27298061

More information

THERMAL ENGINEERING LABORATORY II. To train the students with principles and operation of thermal Engineering equipments.

THERMAL ENGINEERING LABORATORY II. To train the students with principles and operation of thermal Engineering equipments. AIM: THERMAL ENGINEERING LABORATORY II To train the students with principles and operation of thermal Engineering equipments. OBJECTIVES: To experimentally analyze conduction, convection and radiation.

More information

Multistage Centrifugal Blowers

Multistage Centrifugal Blowers Multistage Centrifugal Blowers Multistage Centrifugal Blowers In order to meet all the requirements for air and gas applications, Ingersoll Rand provides a new generation of Hibon Multistage Centrifugal

More information

Industrial Fans & Blowers

Industrial Fans & Blowers Industrial Fans & Blowers IN-LINE FANS ADD DIRECT DRIVE TUBEAXIAL FANS FEATURES & BENEFITS Spark resistant, cast aluminum airfoil axial impeller Aerodynamically efficient performance Factory set adjustable

More information

Analysis and Optimization of Centrifugal Blower Using CFD

Analysis and Optimization of Centrifugal Blower Using CFD Analysis and Optimization of Centrifugal Blower Using CFD Robert Paul. M 1 Department of Mechanical Engineering, Kurinji College of Engineering And Technology, Manapparai, India 1 ABSTRACT: Centrifugal

More information

High-efficiency Turbo Chiller (NART Series)

High-efficiency Turbo Chiller (NART Series) 67 High-efficiency Turbo Chiller (NART Series) Wataru Seki* 1 Kenji Ueda* 1 Jyou Masutani* 2 Yoichirou Iritani* 2 Turbo chillers are widely used for district heating and cooling, heat storage (regeneration)

More information

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS SECTION 23 34 16 CENTRIFUGAL HVAC FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Drawings and general provisions of the contract, including General and Special Conditions and Division 01 Specification

More information

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March GENERAL: 1. This section provides criteria for the design and installation of air handling units. DESIGN GUIDELINES: Design General 1. Location 1.1. For new construction, and existing buildings where possible,

More information

Calculator for Profit From Retained Product

Calculator for Profit From Retained Product Customer Name Location Baghouse Reference Sample Application Anywhere USA Calculator for Profit From Retained Product acfm 207,110 temp (deg F) 250 Dew point (deg F) 65 Humidity Ratio density factor 0.75

More information

GreenJet Transfer Fans

GreenJet Transfer Fans GreenJet Transfer Fans Model GJX High Performance Axial Transfer Fan April 2018 GreenJet As cars park in an underground parking structure, carbon monoxide (CO) and other noxious fumes are emitted into

More information

1 Development and state of the art in road tunnel ventilation technology

1 Development and state of the art in road tunnel ventilation technology 1 Development and state of the art in road tunnel ventilation technology Dipl.-Ing. Wolfgang Müller, Zweibrücken Dipl.-Phys. Jürgen Steltmann, Zweibrücken Development and state of the art in road tunnel

More information

Direct Fired Heater Model AD Specification

Direct Fired Heater Model AD Specification Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI

More information