Vision Series Installation Manual Original instructions

Size: px
Start display at page:

Download "Vision Series Installation Manual Original instructions"

Transcription

1 Vision Series Installation Manual Original instructions English version EN Italian - IT Danish - DK Finnish - FIN Appliance types covered: Model Type xx Vision 5 shelf cooler xx Vision xx Vision xx Vision 21L Integral xx Vision 21E Integral xx Vision 21E Water Cooled xx Vision 21L Water Cooled PART. PI REVISION:. 4 ISSUE DATE: 30/6/2017

2 Installation Manual Dear Customer Please read the User Guide and Installation Manual carefully before operating this unit. Please keep the User Guide and Installation safe and with the unit. Examine the equipment immediately after supply for transport damage. Contact your equipment supplier and/or carrier if necessary. Damage, which arises by inappropriate treatment or operation, is not subject to guarantee \ warranty. Equipment manufactured or supplied by Welbilt (Halesowen) Limited complies with the current legislation and standards of the EU and represents the current standard of technology. Safety during operation may only be assured by following the instructions in this guide. Reproduction of any kind without previously written permission of Welbilt (Halesowen) Limited is prohibited. 2

3 Table of Contents Section 1 Warnings 4-8 Section 2 General Description and Function of the Unit 9 Section 3 Installation & Commissioning of the unit 10 Wiring and system schematics Section 4 Maintenance and Cleaning 25 Section 5 Spare Parts List 29 Section 6 Fault Finding Charts 35 Section 8 Declaration of Conformity 48 3

4 Section 1 Section 1 Warnings WARNING: WARNING: WARNING: WARNING: WARNING: THIS APPLIANCE IS NOT TO BE USED BY PERSONS WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILLITIES OR LACK OF EXPERIENCE AND KNOWLEDGE UNLESS THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION. THIS APPLIANCE IS UNSUITABLE FOR USE BY CHILDREN, AGED OR INFIRM PERSONS. THERE ARE NO END USER SERVICEABLE PARTS. ANY FAULT OR PROBLEM WITH THE EQUIPMENT MUST ONLY BE RECTIFIED BY A QUALIFIED FACTORY APPROVED SERVICE ENGINEER (FAS). ALTHOUGH EVERY CARE IS TAKEN DURING MANUFACTURE, DAMAGE TO THE METALWORK DURING TRANSPORT, INSTALLATION AND GENERAL USE MAY OCCUR. THIS MAY RESULT IN SHARP OR JAGGED EDGES. AVOID CONTACT WITH METAL EDGES OR OTHER POTENTIAL HAZARDS. PLEASE REFER TO MANUAL HANDLING GUIDELINES WHEN LIFTING THIS EQUIPMENT. BEFORE LIFTING OR MOVING THIS EQUIPMENT IT IS RECOMMENDED THAT ALL PERSONS PERFORMING THESE TASKS SHOULD RECEIVE RELEVANT TRAINING IN SAFE HANDLING. ALL PERSONS LIFTING OR MOVING THIS EQUIPMENT MUST BE WEARING THE CORRECT PERSONAL PROTECTIVE EQUIPMENT. 4

5 Section 1 TO PREVENT PERSONAL INJURY WHERE PRACTICAL, TRANSPORTING OF THE UNIT OVER EXTENDED DISTANCES SHOULD BE DONE USING A MECHANICAL AID. ALWAYS TRANSPORT THE UNIT IN THE CORRECT UPRIGHT POSITION, NEVER ON ITS SIDE OR TOP. WARNING: WARNING: WARNING: WARNING: WARNING: WARNING: WARNING: WARNING: WARNING: IT IS UNSAFE TO LIFT OR ATTEMPT TO MOVE THE APPLIANCE DURING CLEANING OR AT ANY OTHER TIME WHEN THE UNIT IS OPERATING. ONLY USE EQUIPMENT FOR ITS INTENDED USE AS DESCRIBED IN THE INSTALLATION MANUAL. THERE ARE NO OTHER RECOMMENDED USES FOR THIS EQUIPMENT. UNINTENDED USE OF THE EQUIPMENT WILL INVALIDATE YOUR WARRANTY. WELBILT (HALESOWEN) LIMITED HAS DONE A COMPLETE QUALITY AND FUNCTION CHECK ON EACH UNIT. NEVERTHELESS, LEAKAGES ON WATER LINES DURING OPERATION CAN NOT BE EXCLUDED TOTALLY. REGULARLY INSPECT THE EQUIPMENT FOR SIGNS OF LEAKAGE. DO NOT DAMAGE THE REFRIGERANT CIRCUIT KEEP ALL VENTILATION OPENENINGS IN THE APPLIANCE CLEAR OF OBSTRUCTION DO NOT USE MECHANICAL DEVICES OR OTHER MEANS TO ACCELERATE THE DEFROSTING PROCESS, OTHER THAN THOSE RECOMMENDED BY THE MANUFACTURER THE EVAPORATION TEMPERATURE IN THE REFRIGERATION CIRCUIT CAN TYPICALLY BE -10 C. WITHOUT TAKING PREVENTATIVE STEPS THIS CAN BE A POTENTIAL SOURCE OF INJURY. THE COMPRESSOR, CONDENSER, HIGH PRESSURE REFRIGERATION TUBES AND MOTORS WILL BECOME HOT DURING OPERATION. CONTACT WITH THESE PARTS DURING OPERATION SHOULD BE AVOIDED. SOME COMPONENTS WILL ROTATE FOR A SHORT PERIOD AFTER THE POWER TO THE UNIT HAS BEEN SWITCHED OFF. THESE COMPONENTS SHOULD BE AVOIDED UNTIL STATIONARY. 5

6 Section 1 WARNING: WARNING: DO NOT DISPOSE OF THE UNIT WITHOUT FIRST REMOVING ALL R134A REFRIGERANT. THIS PROCESS CAN ONLY BE PERFORMED BY AN ENGINEER QUALIFIED TO HANDLE HYDROCARBON REFRIGERANTS. DO NOT DISPOSE OF THE UNIT WITHOUT FIRST REMOVING ALL R290 REFRIGERANT. THIS PROCESS CAN ONLY BE PERFORMED BY AN ENGINEER QUALIFIED TO HANDLE HYDROCARBON REFRIGERANTS. Warning THIS EQUIPMENT IS CHARGED WITH R290 REFRIGERANT (PROPANE). ONLY QUALIFIED SERVICE ENGINEERS HOLDING A VALID HANDLING CERTIFICATE FOR CARE 40 (PROPANE) CAN WORK ON THE REFRIGERATION SYSTEM OF THIS EQUIPMENT. PLEASE READ THE INFORMATION BELOW BEFORE ANY WORK IS CARRIED OUT. Refrigeration R290 (Care 40, Propane) te: Only engineers who have been trained in the safe handling and use of hydrocarbon refrigerants should work on this system. Work on this system in a wall ventilated area or outside. Use a local leak detector to indicate if there is hydrocarbon in the air around the system (place it at a low level as HCs are heavier than air) electrical components) within 3m (10 feet) of your work area. If replacing components use like for like replacements. Take great care when brazing to ensure all HC has been removed from the system. Use refrigerant grade propane (R290 or Care 40) WARNING: WARNING: ALL INSTALLATIONS MUST BE CHECKED THAT THEY MEET LOCAL ELECTRICAL REGULATIONS AND NATIONAL CODES BEFORE THE APPLIANCE IS TURNED ON. ALL UNITS ARE FITTED WITH A STANDARD EURO PLUG TO IEC83:1985 OR A UK PLUG. BEFORE COMMENCING ANY CLEANING ISOLATE THE UNIT BY: 1. SWITCH OFF THE SOCKET THAT THE PLUG IS INSTALLED INTO. 2. REMOVE THE PLUG FROM THE SOCKET. 6

7 Section 1 WARNING: WARNING: WARNING: IF THE MAINS LEAD FITTED TO THIS EQUIPMENT IS IN ANY WAY DAMAGED IT MUST BE REPLACED. THIS WORK SHOULD ONLY BE PERFORMED BY A QUALIFIED ELECTRICAL ENGINEER. THE MAINS LEAD CONECTION IS A Y TYPE. THIS EQUIPMENT MUST BE EARTHED. CARBON DIOXIDE LEAKS ARE POTENTIALLY FATAL IF CONCENTRATIONS RISE TO A DANGEROUS LEVEL. IN VIEW OF THIS THE INSTALLATION SHOULD BE REGULARLY CHECKED FOR INTEGRITY AND THE GENERAL AREA OF INSTALLATION PROPERLY VENTILATED AT ALL TIMES. IT IS RECOMMENDED THAT A CO2 LEAK DETECTOR IS FITTED IN THE VACINITY OF THE EQUIPMENT. THE UNIT SHOULD NOT BE INSTALLED IN A ROOM WHERE SHOULD THE CONTENTS OF THE CO2 BOTTLE BE EVACUATED INTO THE ROOM, CO2 LEVELS WOULD REACH LETHAL LEVELS. C = (Q / N V) [1 - (1 / EN T)] + (C0 - CI) (1 / EN T) + CI (1). WHERE: C = CARBON DIOXIDE CONCENTRATION IN THE ROOM (M3/M3) Q = CARBON DIOXIDE SUPPLIED TO THE ROOM (M3/H V = VOLUME OF THE ROOM (M3) E = THE CONSTANT N = NUMBER OF AIR SHIFTS PER HOUR (1/H) T = TIME (HOUR, H) CI = CARBON DIOXIDE CONCENTRATION IN THE INLET VENTILATION AIR (M3/M3) C0 = CARBON DIOXIDE CONCENTRATION IN THE ROOM AT START, T = 0 (M3/M3) THE VENTILATION IN THE ROOM WHERE THE UNIT IS INSTALLED SHOULD NOT ALLOW THE CO2 CONCENTRATION TO EXCEED 5000PPM WORK PLACE 8 HOUR EXPOSURE LIMIT. BEFORE INSTALLATION A WORK PLACE RISK ASSESSMENT MUST BE PERFORMED CONSIDERING THE RISK ASSOCIATED WITH THE USE OF CO2. 7

8 Section 1 CO2 CYLINDER SAFETY INFORMATION DANGEROUS WARNING 1. ALWAYS connect the CO2 or gas cylinder to a REDUCING VALVE. 2. NEVER try to connect cylinder directly to product container. 3. NEVER interconnect soft drinks, CO2 or gas cylinder equipment with other equipment. 4. ALWAYS secure cylinder upright whilst in use. 5. ALWAYS keep cylinder away from heat. 6. NEVER drop or throw cylinders. 7. NEVER 8. ALWAYS ventilate area after CO2 leakage. This information should be displayed in a position adjacent to the CO2 supply cylinder at all times. WARNING: WARNING: WHEN USED IN A PRECHILLER APPLICATION, IN ORDER TO COMPLY WITH UK WATER REGULATIONS A WRAS APPROVED DOUBLE NON RETURN VALVE MUST BE INSTALLED ON THE INCOMING MAINS WATER SUPPLY BEFORE THE APPLIANCE IN THE SYSTEM. FOR INSTALLATION OF EQUIPMENT ACROSS EUROPE A CLASS 3 PROTECTIVE DEVICE AS DEFINED BY EN1717, APPROVED FOR THE COUNTRY OF INSTALLATION MUST BE INSTALLED ON THE INCOMING MAINS WATER SUPPLY BEFORE THE APPLIANCE IN THE SYSTEM. DO NOT DISPOSE OF THIS EQUIPMENT AS UNSORTED MUNICIPAL WASTE, CONTACT YOUR DISTRIBUTOR OR SERVICE AGENT FOR THE COLLECTION AND SAFE DISPOSAL OF THIS EQUIPMENT. WELBILT (HALESOWEN) LTD. IS A REGISTERED MEMBER OF A WEEE PRODUCER COMPLIANCE SCHEME. 8

9 Section 2 Section 2 General description and function of the unit The Vision series of remote coolers have been designed to combine in one unit a cooler that can be used as a standard ice bank cooler, with the options of modifying the programmable control to enable the use as a glycol cooler. This unit is intended for use as a Cooling unit to cool Beers, Lagers and Ciders to the correct serving temperature. It is designed to be installed in the system between the bulk storage facility and the Dispense Head with the product(s) passing through the cooling coils(s) of the unit This equipment is designed to be installed in cellars, ventilated storerooms and areas generally away from the point of dispense. There are NO other recommended uses for this equipment. This equipment should be used only in accordance with the instructions; it should not be used for any other purpose. The equipment is not intended for use with carbonated soft drinks, fruit juice or milk based beverages. Do not operate the equipment in a wet environment. Any spillage must be wiped dry immediately. The unit should not be installed in small enclosed spaces such as cupboards or Keep the unit free from excessive heat and cold. Minimum and maximum ambient temperatures are: Minimum: 12 C Maximum: 32 C above will invalidate any warranty, and may constitute a danger to yourself and others. This cooler has been subjected to a number of thorough quality checks before leaving the factory. However, to ensure this cooler can meet the demands it has been designed for it must be installed and maintained in accordance with the manufacturer s guidelines. These can be found in this booklet, which must remain with the unit at all times. 9

10 Section 3 Section 3 Installation Unpack the unit from its transportation packing and visually check for any signs of damage. a 10 amp fuse or alternatively a standard Euro Plug to IEC83: Place the unit in a well ventilated, convenient location in the cellar or room where it is to be sited, as close to the point of dispense as possible, within 2m of an electrical socket and without obstructions to the condenser (at the front of the unit) or side and rear panel ventilation slots. Always site the equipment on a dry for installation and cleaning. A minimum clearance of 100mm to either side and rear of the unit and 800mm in front of the unit is recommended. Welbilt do not recommend installing the equipment in close proximity to other heat rejecting equipment as this may reduce performance. Unit V5 V7 V11 V12 V15 V21 V34 Glykool 130 Height / mm Width / mm Depth / mm SYSTEM SCHEMATIC - TYPICAL LAYOUT HEAT DUMP WATER/GLYCOL RECIRCULATION LINES 10mm IDx15mm OD TUBING COBRACOL RECOMMENDED PRODUCT OUT 24 VOLTS AC SUPPLY FROM VISION 3 BASE UNIT PRODUCT OUT PRODUCT IN PRODUCT KEGS 10

11 Section 3 using this cooler with a coolant suppressant, mixture ratios must be as per the coolant suppressant manufacturer s instructions. te: For water cooled units connect the Heat Dump or Glycol module where applicable to the inlet and outlet of the cooler. Please refer to the Heat Dump manual PI or Glycol module manual for guidelines on the units siting, installation and maintenance. the correct ratio of water/ glycol coolant mix (30%) to prevent freezing of the tubes connecting the heat dump to the base unit, which can be exposed to sub-zero temperatures. A 30% glycol / 70% clean water mix will protect the system down to The amount of glycol required for the system - add 2.5 pints (1.4 Litres) for the glycol tank to the length of pipe work as shown in the following tables: Feet Pints Meters Litres

12 Section 3 Connect the re-circulation pump power cable to the socket on the front of the base unit for all appliances other than the Vision 5 shelf cooler which has the power supply to the agitator motor wired internally. Connect the python product tubing to the product coils and python cooling lines to the re-circulation pump. Check that the connections are made correctly and are well prime the system. te: 12

13 Section 3 For all appliances other than the Vision 5 switch the compressor isolate switch bath and if applicable glycol tank levels must be checked and topped up once the system has been primed. Once primed turn the Compressor isolate switch to the on position. Dose the water bath with an appropriate biocide following the manufacturer s instructions and taking note of any health and safety requirements. ELECTRONIC CONTROL SETTINGS AND ADJUSTMENT INSTRUCTIONS DFX SERIES 1E CONTROLLER AND PROBE: The controller is electronic, and is supplied with a temperature probe. The Cut- Out and Cut-In temperatures are factory set at Welbilt (Halesowen) Limited, and should not require any adjustment. They are as follows: Cut-Out: -2.0 C Cut-In: +0.5 C However, the controller has a built-in feature that allows each individual account energy by powering down the cooler overnight, during the account closed period. There is a 7-day timer in the software, with factory default settings which shut the cooler down at 11:00pm and re-start the cooler at 11:00am. For accounts account, in order to maximise energy savings. Please refer to the Dfx Series 1e Instruction Manual sent with the unit for guidance on setting up this feature. Adjustment Guide: te: 1. To adjust the Cut-Out Temperature: A. Carefully remove the lens from the front of the controller. B. Press and hold the button. Release after 2 seconds. C. The display will change from Current Temperature to Current Set-Point. D. Adjust the temperature up or down using the (+) or (-) button. 13

14 Section 3 E. To store the new set-point, press the button. F. adjustment is necessary, replace the lens. The unit will revert to the Current Temperature after 30 seconds. A. Follow steps (a) and (b) above. B. The display will change from Current Temperature to Current Set-Point. C. Press and hold the button again. Release after 2 seconds. D. E. Adjust the temperature up or down using the (+) or (-) button. F. To store the new set-point, press the button. be set to 2.5 C to cause the unit to cut-in at 0.5 C. 3. To adjust the opening and closing hours: te: Opening and closing hours set-up, beginning Sunday: A. Carefully remove the lens from the front of the controller. B. Press and hold the button. Release after 2 seconds. C. The display will change from Current Temperature to Current Set-point. D. Continue to scroll through the menu, by pressing the button for 2 seconds, then releasing, until the display shows HOUR. E. Press and release the button to enter the Opening/Closing hours mode. F. each day is displayed digitally by LEDs, and is not particularly easy to decipher for some of the days. G. To adjust the trading hours for Sunday, in 10 minute increments, follow this procedure... H. corner of the display. This is the Opening Time. I. Adjust the time up or down by using the (+) or (-) buttons. J. When the desired time is displayed, press and release the button again. K. corner of the display. This is the Closing Time. 14

15 Section 3 L. Adjust the time up or down by using the (+) or (-) buttons. M. When the desired time is displayed, press and release the button again. N. right-hand corner of the display. This is the Second Opening Time for Sunday. See below for Opening/Closing options... O. If no Second Opening Time is required, press and release the (+) button until the time scrolls past 24:00, and the next increment displayed is OFF. P. Press and release the button twice to save the settings and move on to the next day (Monday). Q. If a Second Opening Time and Closing Time are required on the same day, this action should follow stage (n) above... R. Adjust the Second Opening Time, using the (+) or (-) buttons. S. When the desired time is displayed, press and release the button again. T. right-hand corner of the display. This is the Second Closing Time. U. Adjust the time by using the (+) or (-) buttons. V. When the desired time is displayed, press and release the button again. W. The display will now show Monday (displayed as rnon ). Rest of the week... X. Use the same procedure to adjust Opening and Closing hours for each day. Y. When the necessary adjustments have been made for all 7 days, press and release the button. The display will show Python Refresh Mode (displayed as pytn). Ignore this mode. Z. Carefully replace the lens. The display will revert back to Current Temperature within 30 seconds. other adjustments should be necessary. Please contact Welbilt (Halesowen) Limited before changing any other parameters, as they may impact on energy savings, performance and ice build. pressure cut-out, the function of which is to protect the refrigeration system in the event of a fault in the system. The cut-out will isolate the power supply to the compressor. Once operated, manual resetting of the cut-out is required before the system will restart. It is recommended that resetting is only undertaken by a suitably trained person who can then identify the possible cause of the initial cutout operation. 15

16 Section 3 Vision 5 wiring schematic: GN/YLW COMP FAN MOTOR GN/YLW RE-CIRC PUMP GN/YLW CONTROLLER 16

17 Section 3 Vision 11 wiring schematic: GRN/YLW ICE BANK CONTROL THERMOSTAT CONNECTION: FAN MOTOR TELEMETERY CONNECT CONNECTION: COMPRESSOR GREEN NEON INDICATOR (COMPRESSOR ON) RED NEON INDICATOR (POWER ON) 17

18 Section 3 Vision 15 wiring schematic: PROBE SWITCH: LINE CLEAN SWITCH: PROBE OVERRIDE CONNECTION: PRESSURE SWITCH CONNECTION: FAN MOTOR CONNECTION: COMPRESSOR 18

19 Section 3 Vision 21E integral wiring schematic: PROBE SWITCH: LINE CLEAN SWITCH: PROBE OVERRIDE CONNECTION: PRESSURE SWITCH CONNECTION: FAN MOTOR 13 CONNECTION: COMPRESSOR 19

20 Section 3 Vision 21E water cooled wiring schematic: 200mm HEAT SHRINK SWITCH: LINE CLEAN SWITCH: PROBE OVERRIDE PROBE CONNECTION: PRESSURE SWITCH GRN /YLW CONNECTION: FAN MOTOR CONNECTION: COMPRESSOR ORANGE T5 AMP VIOLET VIOLET ORANGE F1 AMP IEC CONNECTOR: LID PUMP CONNECTION: HEAT DUMP TERMINAL CONNECTION: TELEMETRY CONNECTION: HEAT DUMP GLYCOL PUMP 20

21 Section 3 Vision 21L Integral wiring schematic: 21

22 Section 3 Vision 21L water cooled wiring schematic 22

23 Section 3 Vision 21 INT Model Wiring Schematic: PROBE SWITCH: LINE CLEAN SWITCH: PROBE OVERRIDE LID PUMP H.P.C.O. FAN MOTOR COMPRESSOR 23

24 Section 3 Vision 21 WC Model Wiring Schematic: PROBE H.P.C.O. GRN /YLW FAN MOTOR COMPRESSOR ORANGE T5 AMP VIOLET VIOLET ORANGE SWITCH: LINE CLEAN SWITCH: PROBE OVERRIDE F1 AMP LID PUMP HEAT DUMP GLYCOL PUMP 24

25 Section 4 Section 4 Maintenance and cleaning Service & Maintenance of the equipment should only be carried out by Welbilt (Halesowen) Limited trained, competent, technicians, abiding by all the relevant statutory regulations and industry recommendations. Before removing the panels from the equipment the mains supply must be disconnected, either by removal of the plug from the wall socket, or in the being powered up. Live testing must be avoided if possible, in most cases components can be tested with a multi-meter or insulation tester, following the instructions laid out in the service manual. Where live testing becomes necessary, all possible precautions to prevent injury to the maintenance technician and other people within the vicinity must be taken. WARNING: Persons performing cleaning/ sanitizing operations MUST be competent and fully trained in safe methods of use of cleaning/sanitising agents and their applications. Personal protective equipment should always be used. or chemicals left in the system could create a health hazard. Do not use a water or steam hose to clean the unit whilst still installed. Regarding the cleaning and sanitising regimes please refer to national/eu regulations. The appliance must be thoroughly sanitised upon installation and before commissioning. thoroughly after extended periods without use. 25

26 Section 4 Cleaning: For the UK please follow the procedure below: BASIC INSPECTION CHECKS BY THE END USER There is no end user training required on this appliance other than understanding the weekly basic checks for safe unit operation. It is not recommended that the end user makes any adjustments or carries out any maintenance other than: 1. Visually check the condition of the mains lead and plug. 2. Visually check the unit and its pipework for evidence of leaks. 3. Visually check the water bath level, if low consult your service agent. 4. Visually check the glycol tank level (water cooled units only), if below the minimum level mark notify your service agent. Welbilt recommend following BFBI system cleaning guidelines; however always ensure that the national legislation and industry cleaning recommendations are followed as these may be more stringent than the UK recommendations detailed bellow: Welbilt recommend a minimum of weekly line cleaning for appliances containing Real Ale, for other alcoholic beverages line cleaning every 2 weeks at a minimum. Line cleaning process: 1. Flush beer from each dispense tap with clean water, so leaks are detected before detergent is bought into the cleaning system and as a pre-rinse to of detergent (normally one pint in a 40 litre bottle) and top up with clean warm water if available temperature for detergent wash should be hand hot approximately 40 degrees Celsius. 3. Pull detergent through the beer lines. 26

27 Section 4 4. Leave lines to soak for 10 minutes, then draw fresh solution through the entire system. e.g.: If line capacity is 2 pints then draw 2 pints through. During 5. After 20 minutes draw another fresh solution of detergent through the lines 6. After 30 minutes the line cleaning cycle should be completed. Never exceed 60 minutes detergent soak time as excess soak time can cause tainted beer lines. with clean water and reconnect to the system line cleaning system and reconnect beer supply. Seasonal Accounts dispense line hygiene Where an outlet ceases trading for a period of time longer than one month it is necessary to carry out a Closedown Procedure. This will reduce the risk of line taints and subsequent replacement of python/dispense equipment: Ensure that all the beer lines have been properly cleaned Empty and rinse cleaning bottle Use a proprietary line sterilising agent Connect to cleaning system and bleed through fob detectors. Open dispense taps and pull through. Remove nozzles from taps, clean and store hygienically. If dispense equipment is exposed to adverse weather conditions it could cause damage to the equipment when sterilising agent and water is left in the lines, clear the lines out with regulated CO2 or Nitrogen via the cleaning ring main. When re-opening outlet: Empty and rinse cleaning bottle Fill with clean warm water Connect to cleaning system and bleed clean water through the bleed valves on the fob detectors Reinstate nozzles on dispense taps gallon of water (e.g. if the line contains 3 pints then 11 pints of water is required through the tap. 27

28 Section 4 1. Isolate the appliance from the mains power supply when maintaining the 2. Remove any extraneous debris from the unit or its casing using a vacuum cleaner or brush. 3. Reconnect the appliancs to the mains power supply. 1. Isolate the unit from the mains electricity supply. 2. Clean and sanitize the product lines following the syrup suppliers\service providers instructions. Welbilt recommend sanitisation of the potable water circuit every 6 months when chlorine is not added to the municipal mains have a 30 minute soak time minimum. 1. Have the appliance service by a factory approved trained technician. 2. Dose the water bath with a bacterial growth inhibitor such as Aquacid, as per the growth inhibitor manufacturer s instructions. In the event of Freezing Up occurring, the following action is recommended: 1. Isolate the unit from Mains Electricity Supply. 2. Identify the fault and rectify. 3. Isolate Product Supply from unit and depressurise the system. 4. Apply gentle warmth to the general area of the unit and its Pipe work. 5. Check for obvious leaks. 6. Turn product supply on / re-pressurise the system whilst continually watching for leaks. 7. Reconnect Mains Electricity supply Observe the unit running for a short period watching out for Leaks, strange noises or any other form of malfunction, if no problems are observed then normal operation of the unit may be resumed. 28

29 Section 5 Section 5 Spare parts list Vision 5 spare parts: REF PART. DESCRIPTION QTY A PI56613 CONTROL 1 B OP73807 FAN BLADE 1 C PI FAN MOTOR 1 D PI FILLER CAP 1 E PU RECIRC PUMP 1 F OP74540 HANDLE 2 29

30 Section 5 Vision 11 & 15 spare parts: 16/ /8 18 Ref Part Number 1 MO PI MM MM CM CM PI PI MM CA CA CA CA CN PI PU PU OP / REF PART. DESCRIPTION QTY 1 MO46691 FAN MOTOR 2 PI FAN BLADE 8 PUSHER 3 MM FRONT GRILL 4 MM SIDE INSPECTION PANELS 5 CM45529 SC15G COMPRESSOR FOR V15 6 CM53227 NL10MFX COMPRESSOR FOR V11 7 PI V15 ELECTRICS BOX 8 PI V11 ELECTRICS BOX 9 MM INSPECTION PANEL 10 CA PRODUCT COIL 1 11 CA PRODUCT COIL 2 12 CA PRODUCT COIL 3 13 CA PRODUCT COIL 4 14 CN CONDENSER STFT PI54306 CASTOR 50MM NYLON 16 PU55117 LID PUMP 3 STG FOR V15 17 PU74485 LID PUMP 2 STG FOR V11 18 OP73884 HANDLE AND PLATE 30

31 Section 5 Vision 21E & Vision 21L Integral spare parts: 4 7/ /10 14 Ref Part N 1 MO4 2 MM0 3 MM0 4 MM0 5 CN4 6 CM7 7 PI53 8 PI42 9 PI01 10 PI01 11 OP7 12 MM42 13 MM42 14 OP7 15 PI REF PART. DESCRIPTION QTY 1 MO46690 FAN MOTOR 2 MM V21 INTEGRAL FRONT PANEL 3 MM V21 RH SIDE PANEL 4 MM V21 LH SIDE PANEL 5 CN49700 CONDENSER LUVE STFT CM73505 COMPRESSOR DANFOSS SC21F 7 PI53949 V21e PRESSURE SWITCH 8 PI42589 V21l THERMAL CONTACT 9 PI V21e ELECTRICS BOX 10 PI V21L ELECTRICS BOX 11 OP71389 FAN BLADE PUSHER MM42634-SL INSPECTION PANEL INNER 13 MM42635-SL INSPECTION PANEL OUTER 14 OP73884 HANDLE AND PLATE ASSY 15 PI MM NYLON CASTOR 31

32 Section 5 Vision 21E & Vision 21L Water cooled spare parts: / /10 14 Ref REF PART. DESCRIPTION QTY 1 MO46690 FAN MOTOR 2 MM V21 WC FRONT PANEL 3 MM V21 RH SIDE PANEL 4 MM V21 LH SIDE PANEL 5 PI PLATE HEAT EXCHANGER 6 CM73505 DANFOSS SC21F COMPRESSOR 7 PI53949 V21e PRESSURE SWICTH 8 PI42589 V21l PRESSURE SWITCH 9 PI V21e ELECTRICS BOX 10 PI V21L ELECTRICS BOX 11 OP71389 FAN BLADE 10 PUSHER 12 MM42634-SL INSPECTION PANEL INNER 13 MM42635-SL INSOECTION PANEL OUTER 14 OP73884 HANDLE ASSY 15 PI54306 CASTER NYLON 50MM 16 PU GP20/12 BASE PUMP GLYCOL 17 PI42544 TRANSFORMER 90VA 32

33 Section 5 Vision 21 INT Model Spares: PART NUMBE 1 PI SA OP SA MM MM OP CA CA PU MM PI CM REF PART. DESCRIPTION QTY 1 PI56328 DFX SERIES 1 CONTROL 1 2 SA EBM IQ 3620 FAN MOTOR 1 3 OP MM FAN BLADE 1 4 SA DANFOSS H.P.C.O SWITCH 1 5 MM SIDE PANEL 2 6 MM FRONT PANEL 1 7 OP73714 COIL BLANK 2 8 CA47138 STD PRODUCT COIL ASSY (3.5M) AS PER. 9 CA43479 LONG PRODUCT COIL ASSY (10M) AS PER. 10 PU55117 SPC18 LID PUMP 1 11 MM FAN MOUTING BRACKET 1 12 PI CONDENSOR 1 13 CM NLE12.6MN COMPRESSOR *NOT SHOWN FOR CLARITY* 1 33

34 Section 5 Vision 21 WC Model Spares: PART NUMBER 1 PI56328 D 2 SA E 3 OP SA DA 5 MM MM OP CA43479 STD P 9 CA43479 LONG 10 PU MM FA 12 PI PU PI CM NL *NO REF PART. DESCRIPTION QTY 1 PI56328 DFX SERIES 1 CONTROL 1 2 SA EBM IQ 3620 FAN MOTOR 1 3 OP MM FAN BLADE 1 4 SA DANFOSS H.P.C.O. SWITCH 1 5 MM SIDE PANEL 2 6 MM FRONT PANEL 1 7 OP73714 COIL BLANK 2 8 CA43479 STD PRODUCT COIL ASSY (3.5M) AS PER. 9 CA43479 LONG PRODUCT COIL ASSY (10M) AS PER. 10 PU55117 SPC18 - LID PUMP 1 11 MM FAN MOUNTING BRACKET 1 12 PI PLATE B.P.H.E PU GP20/12 BASE PUMP 1 14 PI vA TRANSFORMER 1 15 CM NLE12.6MN COMPRESSOR *NOT SHOWN FOR CLARITY* 1 34

35 Section 6 FAULT DIAGNOSIS FLOW CHART 1 COMPRESSOR Is the compressor running? Is the unit in a Is line clean high ambient switch on? Is the unit s bath temperature at its set point? Switch line Re-site Unit Has there been excessive product draw? and start relay End Is there a probe on Stat Leave unit to recover Is the compressor running? Is the python length excessive or exposed to high temperatures? Faulty Re-route python and resite unit closer to dispense point 35

36 Section 6 FAULT DIAGNOSIS FLOW CHART 2 COMPRESSOR Is the compressor running? Is compressor Is the unit in a high ambient temp Switch compressor isolate switch to on Resite unit Has there been excessive product draw Is compressor running Leave unit to recover Change capicitor and start relay End End Is the python length excessive or exposed to high temperatures Is compressor running Check for refrigerant leaks Re - route python and resite unit closer to dispense point Faulty compressor 36

37 Section 6 FAULT DIAGNOSIS FLOW CHART LID DUMP around the system? but 37

38 Section 6 FAULT DIAGNOSIS FLOW CHART HEAT DUMP Is heat dump fan running Is heat dump connected to unit Is radiator matrix blocked restricting Check for 24V supply at head dump socket Plug heat dump connection into socket Clean radiator matrix Is the heat dump sited in full sunlight or near other heat sources without adequate ventilation Check for 24V output at transformer Check for 24V supply at heat dump Re site heat dump Check Fuses Internal wiring fault Faulty wire between unit & heat dump Replace fan motor Ok Replace Transformer 38

39 Section 6 FAULT DIAGNOSIS FLOW CHART GLYCOL PUMP Does the pump run Is pump plugged into it s mating connection Is header tank glycol level between max - min marks Check for 240v supply at connection Plug pump into connection Top up to maximum level and check for leaks Is the glycol mixture recirculating Faulty pump motor Internal wiring fault Go to heat dump fault diagnosis chart Are the valves open on pump Faulty pump Open shut Have the glycol lines collapsed been restricted, blocked or secured together Ensure tubing is the correct type and ensure pipes are not secured together and are away from heat sources. Clear blockage restriction 39

40 Section 7 Vision 5 Performance Ice Bank Pull 19 C Ambient Waterbath Physical Data Electrical Refrigeration Controls System Protection Coils Ice Bank Weight VISION 5 INTEGRAL 95 mins 4 kg Max Operating Ambient Temperature 32 C Height Width Depth Waterbath Dry Weight Operating Weight Mains Voltage Run Current Fuse Rating Compressor Size -10 C Evaporation Refrigerant Charge Climate Class 3 Ice Bank Compressor Recirculation Pump Coil Lid 275 mm 515 mm 375 mm 12 litres 23 kg 35 kg 230V 1.8 amps 5 amps 5.7cc 454 Watts* R g C02(e) 0.195kg Electronic Klixon (Auto reset) Thermal overload 2 x 5.5m x 3/8 Coils, 316 stainless steel * Compressor manufacture s data for -10 C evaporation temperatures, according to EN Household (CECOMAF) 40

41 Section 7 Vision 11 Performance VISION 11 INTEGRAL Ice Bank Pull 19 C Ambient Waterbath 3.22 Physical Data Electrical Refrigeration Controls System Protection Coils Ice Bank Weight 11kg (nominal) Max Operating Ambient Temperature 32 C Height Width Depth Waterbath Dry Weight Operating Weight Mains Voltage Run Current Fuse Rating Compressor Size -10 C Evaporation Refrigerant Charge Climate Class 3 Ice Bank Compressor Recirculation Pump Plain Lid Coil Lid 730 mm 425 mm 500 mm 28 litres 35.2 kg 63.2 kg 230V 5.0 amps 10 amps 10cc 441 Watts* R-134a 185 g C02(e) 262.7kg Mechanical Klixon (Auto reset) Thermal overload (Auto reset) 0 coils 4 x 6m 3/8 Coils, 316 stainless steel * Compressor manufacture s data for -10 C evaporation temperatures, according to EN Household (CECOMAF) 41

42 Section 7 Vision 15 Performance VISION 15 INTEGRAL Ice Bank Pull 19 C Ambient Waterbath 2:45 Physical Data Electrical Refrigeration Controls System Protection Coils Ice Bank Weight 11 kg (nominal) Max Operating Ambient Temperature 32 C Height Width Depth Waterbath Dry Weight Operating Weight Mains Voltage Run Current Fuse Rating Compressor Size -10 C Evaporation Refrigerant Charge Climate Class 3 Ice Bank Compressor Recirculation Pump Plain Lid Coil Lid 770 mm 425 mm 500 mm 28 litres 43.5 kg 61.5 kg 230V 5.0 amps 10 amps 8.8cc 689 Watts* R g C02(e) 0.315kg Electronic Klixon (Auto reset) Thermal overload (Auto reset) 0 coils 4 x 6m 3/8 Coils, 316 stainless steel * Compressor manufacture s data for -10 C evaporation temperatures, according to EN Household (CECOMAF) 42

43 Section 7 Vision 21 Performance VISION 21 INTEGRAL VISION V21 WATER-COOLED Ice Bank Pull 19 C Ambient Waterbath 3:50 (no python) 3:50 (no python) Physical Data H Electrical Refrigeration Controls System Protection Coils W Ice Bank Weight 22 Kg (nominal) 22 Kg (nominal) Max Operating Ambient Temperature 32 C 32 C D Height 900 mm 900 mm Width 540 mm 540 mm Depth 660 mm 660 mm Waterbath 62 litres 62 litres Dry Weight 64.8 kg 67 kg Operating Weight kg 129 kg Mains Voltage 230V/50Hz Single Phase 230V/50Hz Single Phase Run Current 4.6 amps 5.2 amps Fuse Rating 10 amps 10 amps Compressor Size 14.5cc 14.5cc -10 C Evaporation 1098 Watts* 1098 Watts* Refrigerant R290 R290 Charge 390g 110g Climate Class 3 C02(e) 1.17kg C02(e) 3.3kg Ice Bank Electronic Electronic Compressor Klixon (Thermal Overload) Klixon (Thermal Overload) Recirculation Pump Thermal overload Thermal overload Short 3/8 (9.5mm) OD x 3m 316 SS - Max Qty 14 3/8 (9.5mm) OD x 3m 316 SS - Max Qty 14 Long 3/8 (9.5mm) OD x 3.8m 316 SS - Max Qty 14 3/8 (9.5mm) OD x 3.8m 316 SS - Max Qty 14 X Long 3/8 (9.5mm) OD x 5m 316 SS - Max Qty 14 3/8 (9.5mm) OD x 5m 316 SS - Max Qty 14 XX Long 3/8 (9.5mm) OD x 10m 316 SS - Max Qty 8 3/8 (9.5mm) OD x 10m 316 SS - Max Qty 8 Super Long 3/8 (9.5mm) OD x 12m 316 SS - Max Qty 6 3/8 (9.5mm) OD x 12m 316 SS - Max Qty 6 * Compressor manufacture s data for -10 C evaporation temperatures, according to EN Household (CECOMAF) 43

44 Table 3 Climate classes TEST ROOM CLIMATE CLASS DRY BULB TEMPERATURE RELATIVE HUMIDITY DEW POINT WATER VAPOUR MASS IN DRY AIR C % C g/kg NOTE of the cabinets. See also Annex D to compare lab and store conditions. 44

45 45

46 46

47 47

48 Section 8 Section 8 Declaration of conformity EC Declaration of Conformity In accordance with the EC Guidelines - Regulation (EC) 765/ Decision 768/2008/EC + Regulation (EC) 1221/2009 New Legislative Framework Directives /95/EC General Product Safety Directive /42/EC - Machinery Directive /68/EU Pressure Equipment Directive /30/EU - EMC Directive /65/EU - RoHS Directive /96/EC WEEE Directive /2004/EC - Food Safety Regulation - 10/2011/EU - Plastic Materials in Contact with Food Regulation /2006/EC - Good Manufacturing Practice for Articles in Contact with Food Regulation /2006/EC REACH Regulation - 517/2014/EU F GAS Regulation /2009/ EC Ozone depleting substances Regulation - Water Supply (Water Fittings) Regulations of 1999 Marking of the equipment: xx Vision 5 shelf xx Vision 21 R134a W/C xx Vision 21 R134a INT xx Vision 21 EC R134a W/C xx Vision 21 EC R134a INT xx Vision 21 R xx Vision 21E R134a INT xx Vision 21E R134a W/C xx Vision 15 R134a xx Vision 11 R134a xx Vision 21L R134a INT xx Vision 21L R134a W/C xx Vision 21E R290 INT xx Vision 21E R290 W/C xx Vision 15 R290 The above named appliances have been developed, built and manufactured in agreement with above listed EC Guidelines in sole responsibility of the company Welbilt (Halesowen) Limited The following coordinated standards have been applied: - EN 378-1: A2: EN 378-2: A1: EN : A1: A2: EN A EN 50581: EN : A1: A2: EN : A11:2014 (IEC edition 5) - EN :2010 (IEC edition 2) - EN : EN : EN 62233: BS6920-1: Italian Ministerial Decree further ammendments A complete technical documentation is available. A quality safety system according to DIN ISO 9001 is installed in the business. Welbilt (Halesowen) Limited Chancel Way, Halesowen West Midlands, B62 8SE, UK Tel: Fax:

REMOTE COOLER AIR COOLED & WATER COOLED

REMOTE COOLER AIR COOLED & WATER COOLED REMOTE COOLER AIR COOLED & WATER COOLED Installation & User Instructions (To be left with the user) PLEASE READ CAREFULLY BEFORE INSTALLING THE UNIT Please follow these instructions carefully. Only if

More information

SUPER ASTRA PRODUCT MANUAL. PM R20 Issue 3 1/00

SUPER ASTRA PRODUCT MANUAL. PM R20 Issue 3 1/00 PRODUCT MAUAL PM R20 Issue 3 1/00 COTETS 1. Introduction... 1 2. Specification... 1 3. Installation... 2 4. Service Information... 3 5. User Maintenance... 3 1. ITRODUCTIO Super Astra is a compact beer

More information

Product Manual. Model Number Range XX XX

Product Manual. Model Number Range XX XX Product Manual Model Number Range 06 1 3601XX 06 1 3602XX Doc Ref: 58 0908 201 Latest rev date: 17.05.2012 Applies to Index remote cooler range: - Index21 AC, Air cooled models with part code commencing

More information

Product Manual. Viscount IV series of carbonators and chillers. Part Number 3B3075 Issue 01 [ ]

Product Manual. Viscount IV series of carbonators and chillers. Part Number 3B3075 Issue 01 [ ] Product Manual Viscount IV series of carbonators and chillers Part Number 3B3075 Issue 01 [16-04-07] Contents Section Page Section Page Introduction 2 Safety 2 Description 2 Schematics 4 Fault Finding

More information

User Manual WMF Cup&Cool WMF Cup

User Manual WMF Cup&Cool WMF Cup coffee wakes up the world User Manual WMF Cup&Cool WMF Cup Add-on Equipment English bistro! 2000S presto! 1400 prestolino! 1300 Model Series 9018 / 9019 Order Nr. 33 0916 1000 Edition 04.2010 General Information

More information

VR60 GLASS FROSTERS INSTALLATION AND OPERATING MANUAL PLEASE LEAVE WITH OPERATOR. VR60 Glass Froster. Series 1

VR60 GLASS FROSTERS INSTALLATION AND OPERATING MANUAL PLEASE LEAVE WITH OPERATOR. VR60 Glass Froster. Series 1 VR60 GLASS FROSTERS INSTALLATION AND OPERATING MANUAL PLEASE LEAVE WITH OPERATOR VR60 Glass Froster Series 1 Imperial Machine Company Limited Unit 1, Abbey Road Wrexham Industrial Estate Wrexham LL13 9RF

More information

USER MANUAL. Pharmacy Refrigerator Range. Applicable models: PSR353/PGR353 PSR273/PGR273 PSR151/PGR151

USER MANUAL. Pharmacy Refrigerator Range. Applicable models: PSR353/PGR353 PSR273/PGR273 PSR151/PGR151 USER MANUAL Pharmacy Refrigerator Range Applicable models: PSR353/PGR353 PSR273/PGR273 PSR151/PGR151 1 Contents Before first use 3 Positioning of refrigerator 3 Transportation and moving of refrigerator

More information

Introduction to the Cornelius CRYOCOOL 100 System for Extra-cold Products and Detailed Information for Surveying, Installation and Commissioning

Introduction to the Cornelius CRYOCOOL 100 System for Extra-cold Products and Detailed Information for Surveying, Installation and Commissioning Introduction to the Cornelius CRYOCOOL 100 System for Extra-cold Products and Detailed Information for Surveying, Installation and Commissioning Issue 2 06/05/05 Contents Page The System Product Overview

More information

USER MANUAL. Laboratory Refrigerator Range. Applicable models: LSR151 LSR288

USER MANUAL. Laboratory Refrigerator Range. Applicable models: LSR151 LSR288 USER MANUAL Laboratory Refrigerator Range Applicable models: LSR151 LSR288 1 Contents Before first use 3 Positioning of refrigerator 3 Transportation and moving of refrigerator 3 Energy saving tips 4 Important

More information

Autofill Wall Mount Boilers

Autofill Wall Mount Boilers USER INSTRUCTION MANUAL Autofill Wall Mount Boilers HELPLINE 0844 372 7766 Redring Warranty 2 Year Parts 2 Year Labour 083329501-05/12/13 Contents 1.0 About your Product My Product (please complete this

More information

Double Door - Dual Zone Wine Cooler

Double Door - Dual Zone Wine Cooler THE PERFECT BALANCE OF FUNCTION, STYLE AND RELIABILITY LAUNDRY - DISHWASHING - COOKING - COOLING Installation and Operating Manual Double Door - Dual Zone Wine Cooler WS38SDDX Stainless Steel Please read

More information

Progress plus Instruction manual

Progress plus Instruction manual GB Progress plus Instruction manual Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 10 Please read this user s manual carefully to ensure proper use, maintenance and installation.

More information

For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER. Instruction Manual

For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER. Instruction Manual For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER Instruction Manual Please read these instructions carefully before use and retain for future reference. Before switching on your

More information

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS 3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: 32305600 OPERATION & MAINTENANCE INSTRUCTIONS 0304 Parts List Item Part No Description Qty 1 FT900001 Top Cover 1 2 FT900002 Filter

More information

Installation & Operating Instructions

Installation & Operating Instructions PREMIUM Installation & Operating Instructions m AQP-3TAP-SS Platinum Water Dispenser Hot/Cold & Room Premium Selection Congratulations on your purchase of an Aquaport Platinum Water Dispenser Thank you

More information

The Professional s Choice

The Professional s Choice CPF Series Models: CPF2100, CPF210, CPF310, CPF4100-3, CPF4100-6 & CPF6100 Auto-Fill Catering Water Boiler With Integrated Multi-Filter Installation And User Instructions The Professional s Choice INSTANTA

More information

Recirculating Chiller RC350G-RC400G RC1400G-RC3000G. Operating Manual

Recirculating Chiller RC350G-RC400G RC1400G-RC3000G. Operating Manual Recirculating Chiller RC350G-RC400G RC1400G-RC3000G Operating Manual Part No 09931/Issue 10 Page 2 April 2010 CONTENTS 1 Safety 4 2 Installation 5 2.1 Connection for closed loop circulation 6 2.2 Connection

More information

Cabinet Refrigerators/Freezers Instruction manual

Cabinet Refrigerators/Freezers Instruction manual Cabinet Refrigerators/Freezers Instruction manual Model DL893-A/DL894-A/DL895-A/DL896-A/DL897-A/DL898-A/DL899-A /CK480-A Safety Tips Position on a flat, stable surface. A service agent/qualified technician

More information

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1 Instruction Manual M6627 / Version 7.4 Slide Drying Bench MH6616 MH6616X1 Please take your time to read this Instruction Manual in order to understand the safe and correct use of your new Electrothermal

More information

Portable Air Conditioner USER MANUAL

Portable Air Conditioner USER MANUAL AC12 AC12HP Portable Air Conditioner USER MANUAL Thank you for choosing this innovative Amcor air conditioner. We suggest that you keep this manual in a safe place for future reference. It describes the

More information

PRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL. Indoor Convective Panel Heater

PRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL. Indoor Convective Panel Heater PRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL Indoor Convective Panel Heater CONTENTS Rev A NOV14 1. Product Overview 2. Specification Data 3. Operations 4. Installation 5. Safety 6. Maintenance

More information

Operating instructions Page 12

Operating instructions Page 12 Operating instructions Page 12 Refrigerator with explosion-proof interior container Read the operating instructions before switching on for the first time 7082 271-00 LKEXv 910 Disposal notes The appliance

More information

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL Thank you for choosing ElectriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference. Visit our

More information

User and Installation Instructions C6R/75, C6R/100, C6R/105, C6R/125, C6R/130, D6R/100, D6R/125, D5R/100, D5R/125, D3R/100

User and Installation Instructions C6R/75, C6R/100, C6R/105, C6R/125, C6R/130, D6R/100, D6R/125, D5R/100, D5R/125, D3R/100 User and Installation Instructions Seal Refrigerated Merchandisers C6R/75, C6R/100, C6R/105, C6R/125, C6R/130, D6R/100, D6R/125, D5R/100, D5R/125, D3R/100 IS281 ECN3045 Dear Customer, Thank you for purchasing

More information

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

COMPACT PORTABLE AIR CONDITIONER USER MANUAL COMPACT PORTABLE AIR CONDITIONER USER MANUAL Thank you for choosing ElectriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference. Visit our page

More information

The Professional s Choice

The Professional s Choice SureFlow compact range: 1000-C & 1000-M Auto-Fill Catering Water Boiler Installation And User Instructions The Professional s Choice CONTENTS CONTENTS & INTRODUCTION 2 SAFETY & ENVIRONMENTAL INFORMATION

More information

Stainless Steel Counter Refrigerators Instruction manual

Stainless Steel Counter Refrigerators Instruction manual Stainless Steel Counter Refrigerators Instruction manual Model G596-A/G597-A/G622-A/U636-A Safety Tips Position on a flat, stable surface. A service agent/qualified technician should carry out installation

More information

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER USER MANUAL SILENT16 PORTABLE AIR CONDITIONER Thank you for choosing electriq Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference. Visit our

More information

LARDER Instruction booklet

LARDER Instruction booklet TM LARDER Instruction booklet RTL266WHA+ Index BEFORE USING YOUR FRIDGE... 2 General warnings... 2 Old and out-of-order fridges... 4 Safety warnings... 4 Installing and Operating your Fridge... 5 Before

More information

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W 10L Dehumidifier Model Number: LDH1001 220-240V AC 50/60Hz 290W For Customer Services & Spare Parts please call 0345 209 7461 Opening times: Monday - Friday 8am 8pm & Saturday 9am 1pm Or visit us at www.productcare.co.uk

More information

USER GUIDE VOGUE MAX SYSTEM

USER GUIDE VOGUE MAX SYSTEM USER GUIDE VOGUE MAX SYSTEM 15 18 26 32 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not

More information

USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE USE.

USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE USE. 65L Dual Zone Fridge USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE USE. SAFETY INSTRUCTIONS Please read the user manual and safety instructions carefully before using the appliance.

More information

FWC860 Wine Cooler Installation, Use and Maintenance

FWC860 Wine Cooler Installation, Use and Maintenance FWC860 Wine Cooler Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu W :

More information

OSD10, OSD20 & OSD30 DRINK DISPENSER

OSD10, OSD20 & OSD30 DRINK DISPENSER INSTRUCTION MANUAL Eat well, drink well and live well with Omega www.omegajuicers.com OSD10, OSD20 & OSD30 DRINK DISPENSER English PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USE OMGMAN 082009 RevA

More information

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax: TECHNICAL MANUAL CX(E) SPLIT SYSTEMS CONTENTS INDEX PART NUMBERS, OPTIONS, UNIT COMBINATIONS, DIMENSIONS & WEIGHTS 3 PERFORMANCE DATA & AIR FLOW 4 SOUND POWER AND SOUND PRESSURE LEVELS 5 ELECTRICAL DATA

More information

Instruction Manual 1.1 CU. FT. Upright Freezer UF-114W (WHITE) UF-114SS (STAINLESS STEEL)

Instruction Manual 1.1 CU. FT. Upright Freezer UF-114W (WHITE) UF-114SS (STAINLESS STEEL) Instruction Manual 1.1 CU. FT. Upright Freezer UF-114W (WHITE) UF-114SS (STAINLESS STEEL) SAFETY WARNINGS 1) WARNING Keep ventilation openings, in the appliance enclosure or in the built-in structure,

More information

Operating instructions Page 6

Operating instructions Page 6 Operating instructions Page 6 Refrigerator with explosion-proof interior container Read the operating instructions before switching on for the first time 7083 045-00 LKexv Disposal notes The appliance

More information

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40 USER GUIDE VOGUE COMBI GEN2 C26 C32 C40 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not

More information

Built-under larder fridge instruction manual RBL4. Contact Caple on or for spare parts

Built-under larder fridge instruction manual RBL4. Contact Caple on or for spare parts Built-under larder fridge instruction manual RBL4 Contact Caple on 0117 938 7420 or for spare parts www.caple.co.uk CONTENTS Warnings 3 Installation warnings 7 Before using your fridge 10 How to operate

More information

Optimax Refrigerated Retail Merchandisers

Optimax Refrigerated Retail Merchandisers V Optimax Refrigerated Retail Merchandisers MODEL NUMBERS RMR65E/SMR65ECT RMR100E/SMR100ECT RMR130E/SMR130ECT RMR65S RMR100S RMR130S RMR65SW RMR100SW RMR130SW RMR65SP RMR100SP RMR130SP Assisted service

More information

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A Blast Chiller / Freezer Instruction Manual Model DN492-A DN494-A 1 Safety Tips Position on a flat, stable surface. A service agent/qualified technician should carry out installation and any repairs if

More information

fwc152 / fwc303 / fwc603 / fwc623 Wine Coolers Manual for Installation, Use and Maintenance

fwc152 / fwc303 / fwc603 / fwc623 Wine Coolers Manual for Installation, Use and Maintenance fwc152 / fwc303 / fwc603 / fwc623 Wine Coolers Manual for Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949

More information

INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS PIE CABINET

INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS PIE CABINET Page 1 of 11 INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS PIE CABINET MODEL: SPC Page 2 of 11 PLEASE NOTE INSTALLATION OF PIE CABINET MUST BE CARRIED OUT BY A QUALIFIED ELECTRICIAN IMPORTANT

More information

PC87 American Style Double Door Fridge Freezer Manual for Installation, Use and Maintenance

PC87 American Style Double Door Fridge Freezer Manual for Installation, Use and Maintenance PC87 American Style Double Door Fridge Freezer Manual for Installation, Use and Maintenance 1 Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949

More information

A few simple steps to ensure perfect water, every time.

A few simple steps to ensure perfect water, every time. A few simple steps to ensure perfect water, every time. Use and Care Guide MODELS: A7BOTTLELESS A7BOTTLELESSBLK Registration Please visit the website below to register your new water cooler within the

More information

Arctic EVAPORATIVE COOLER USER MANUAL

Arctic EVAPORATIVE COOLER USER MANUAL Arctic EVAPORATIVE COOLER USER MANUAL Thank you for choosing ElectriQ Please read this user manual before using this innovative Air Cooler and keep it safe for future reference. Visit our page www.electriq.co.uk

More information

30-pint Dehumidifier User Guide

30-pint Dehumidifier User Guide 30-pint Dehumidifier User Guide IVADH30PW Thank you for purchasing the Ivation 30 Pint Dehumidifier. This User Guide is intended to provide you with guidelines to ensure that operation of this product

More information

FWC152 / FWC302 / FWC602 / FWC622 Wine Coolers

FWC152 / FWC302 / FWC602 / FWC622 Wine Coolers FWC152 / FWC302 / FWC602 / FWC622 Wine Coolers Manual for Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949

More information

DEHUMIDIFIER MODELS: SD-31E / SD-41E / SD-61E / SD-71E INSTRUCTION MANUAL

DEHUMIDIFIER MODELS: SD-31E / SD-41E / SD-61E / SD-71E INSTRUCTION MANUAL DEHUMIDIFIER MODELS: SD-31E / SD-41E / SD-61E / SD-71E INSTRUCTION MANUAL Please read these instructions thoroughly and keep it in a safe place for future reference. CONTENTS SAFETY PRECAUTUIONS... 2 ELECTRICAL

More information

LED Bottle Cooler. Maintenance for. I1457 Iss. 4 Jan 2014 Copyright Glen Dimplex Professional Appliances

LED Bottle Cooler. Maintenance for. I1457 Iss. 4 Jan 2014 Copyright Glen Dimplex Professional Appliances Maintenance for LED Bottle Cooler Lec Commercial Glen Dimplex Professional Appliances A division of Glen Dimplex Home Appliances Stoney Lane, Prescot, Merseyside, L35 2XW Great Britain T: 0871 222 5119

More information

PRE-INSTALLATION PROCEDURE

PRE-INSTALLATION PROCEDURE PRE-INSTALLATION PROCEDURE Required with each BLUPURA Water Treatment System. 1 each External Filter 1 each Chiller 1 each CO 2 Regulator 1 each External Filter 1 each Water Pressure Regulator 1 each 4

More information

DOMETIC PTY. LTD. Camping Boxes-Refrigerator. Models: RC 1600 EGP Type: JCB - 1. Operating Instructions AUS

DOMETIC PTY. LTD. Camping Boxes-Refrigerator. Models: RC 1600 EGP Type: JCB - 1. Operating Instructions AUS DOMETIC PTY. LTD. Camping Boxes-Refrigerator Models: RC 1600 EGP Type: JCB - 1 Operating Instructions AUS 207.5911.15 Please read these operating instructions carefully before putting the refrigeration

More information

1.0 INTRODUCTION 3 TABLE OF CONTENTS 2.0 FOR YOUR SAFETY Warnings and Safety Advice Coolants WARRANTY AND 3 CUSTOMER SERVICE 4.0 INS

1.0 INTRODUCTION 3 TABLE OF CONTENTS 2.0 FOR YOUR SAFETY Warnings and Safety Advice Coolants WARRANTY AND 3 CUSTOMER SERVICE 4.0 INS MANUAL minibar RH 436D RH 447D RH 430LD RH 440LD RH 441LD RH 455LD RH 456LD RH 460LD RH 461LD RH 456LDE English Type H20 / 60 821 2693-81 T.D. 07/02 1.0 INTRODUCTION 3 TABLE OF CONTENTS 2.0 FOR YOUR SAFETY

More information

The Professional s Choice

The Professional s Choice DB2000 Push Button Dispense Boiler Installation And User Instructions The Professional s Choice CONTENTS CONTENTS & INTRODUCTION 2 SAFETY INFORMATION 2 ENVIRONMENTAL INFORMATION & DELIVERY CHECKLIST 3

More information

Contents Safety Warnings... 3 Unpacking... 5 Installation... 6 Product Overview Operation Cleaning Maintenance...

Contents Safety Warnings... 3 Unpacking... 5 Installation... 6 Product Overview Operation Cleaning Maintenance... L5017W/S/B Contents Safety Warnings... 3 Unpacking... 5 Installation... 6 Location...6 Levelling the Unit...6 Free Space Requirements...6 Reversing the Door Swing...7 Cleaning Before Use... 10 Before Using

More information

Refrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24

Refrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24 Refrigeration / Air Conditioning Systems Circuit Drawings Nominal Student Hours: Student Resource Package No: NR 24 24 Hours. Delivery: Recognition of Prior Learning: Package Purpose: Suggested Resources:

More information

User manual: Stainless steel CGN range Storage Refrigerators and FGN Storage Freezers

User manual: Stainless steel CGN range Storage Refrigerators and FGN Storage Freezers User manual: Stainless steel CGN range Storage Refrigerators and FGN Storage Freezers To ensure safe operation, please read this user manual thoroughly before use. 2017 Husky. Husky reserve the right to

More information

IMPORTANT: RETAIN FOR FUTURE REFERENCE

IMPORTANT: RETAIN FOR FUTURE REFERENCE Black Freestanding 8 Bottle Wine Cooler User Guide Model number: RH8WC1 IMPORTANT: RETAIN FOR FUTURE REFERENCE Contents Safety Instructions. 2-3 Before Switching On. 3 Installing and Switching on Your

More information

INSTRUCTIONS MODEL: MWBT

INSTRUCTIONS MODEL: MWBT Page 1 of 15 INSTRUCTIONS MODEL: MWBT SAFETY INSTRUCTIONS INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS WIRING DIAGRAM EXPLODED VIEW / PARTS LIST WARRANTY INFORMATION DISPOSAL

More information

Heated Display Merchandiser. Instruction Manual. Models: GC875-A / GC876-A / GC877-A

Heated Display Merchandiser. Instruction Manual. Models: GC875-A / GC876-A / GC877-A Heated Display Merchandiser Instruction Manual Models: GC875-A / GC876-A / GC877-A Safety Tips Position on a flat, stable surface. A service agent/qualified technician should carry out installation and

More information

Important Notes: Please read carefully before installing your refrigerator.

Important Notes: Please read carefully before installing your refrigerator. Model: Important Notes: Please read carefully before installing your refrigerator. This Labcold product has been made with great care, tested thoroughly before being sent to you, and is expected to give

More information

VANTAGE. Installation Manual. Release Date: April 16, 2003 Publication Number: INS Revision Date: January 22, 2015 Revision: E

VANTAGE. Installation Manual. Release Date: April 16, 2003 Publication Number: INS Revision Date: January 22, 2015 Revision: E VANTAGE Installation Manual Release Date: April 16, 2003 Publication Number: 3120031005INS Revision Date: January 22, 2015 Revision: E Visit the Cornelius web site at www.cornelius.com for all your Literature

More information

INSTRUCTION MANUAL HETO CBN 8 / 18 / C Cooling Baths ID: IM.doc Revision 1

INSTRUCTION MANUAL HETO CBN 8 / 18 / C Cooling Baths ID: IM.doc Revision 1 Revision 1 INSTRUCTION MANUAL HETO CBN 8 / 18 / 28-30 - 30 C Cooling Baths ID: 88872215 Page 2 / 9 INSTRUCTION MANUAL CBN 8 / 18 / 28-30 Important user information Please read this entire manual to fully

More information

smeg LARDER Instruction booklet

smeg LARDER Instruction booklet smeg LARDER Instruction booklet Index BEFORE USING YOUR FRIDGE... 2 Safety Instructions... 2 Safety warnings... 3 Installing and Operating your Fridge... 4 Before Using your Fridge... 4 USAGE INFORMATION...

More information

Model Modèle Modell Modello Modelo Malli:

Model Modèle Modell Modello Modelo Malli: 600 / 400 / 150 litre series Refrigerators/Freezers Instruction manual Model Modèle Modell Modello Modelo Malli: CD080-A/CD081-A/CD082-A/CD083-A/CD084-A/CD085-A/CD610-A/CD611-A/ CD612-A/CD613-A/CD614-A/CD615-A/CD086-A/CD087-A/CD088-A

More information

SELF-CONTAINED CRESCENT CUBER

SELF-CONTAINED CRESCENT CUBER Reliability is a beautiful thing TM SELF-CONTAINED CRESCENT CUBER KM-250BAF KM-250BWF INSTRUCTION MANUAL ISSUED: March 14, 2000 REVISED: December 22, 2004 IMPORTANT Only qualified service technicians should

More information

FWC153, FWC304, FWC604 & FWC624

FWC153, FWC304, FWC604 & FWC624 FWC153, FWC304, FWC604 & FWC624 Wine Coolers Installation, use and maintenance www.cda.eu Important The CDA Group Ltd cannot be held responsible for injuries or losses caused by incorrect use or installation

More information

Zip Tudor. Affix Model Number Label Here Installation Section & Operating Heading Instructions. Single point open outlet (vented) water heaters

Zip Tudor. Affix Model Number Label Here Installation Section & Operating Heading Instructions. Single point open outlet (vented) water heaters Zip Tudor Installation Section & Operating Heading Instructions Single point open outlet (vented) water heaters Affix Model Number Label Here 81333 Above-Sink Tudor (No tapware included) Accessory Tapware

More information

FWC152, FWC303, FWC603 & FWC623 Wine Coolers Installation, Use and Maintenance

FWC152, FWC303, FWC603 & FWC623 Wine Coolers Installation, Use and Maintenance FWC152, FWC303, FWC603 & FWC623 Wine Coolers Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E :

More information

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference. SAFETY INSTRUCTIONS Important! Carefully

More information

Manual is for the following models: G-26 GCG-26 GCG-26-C31N* G-26-C31N* GCG-26-C231N* GCG-26-CA31N* *G,I,M,7,J plug. Instruction Manual.

Manual is for the following models: G-26 GCG-26 GCG-26-C31N* G-26-C31N* GCG-26-C231N* GCG-26-CA31N* *G,I,M,7,J plug. Instruction Manual. G-Series Cooler G-26c/GCG-26c UPRIGHT COOLER Manual is for the following models: G-26 GCG-26 GCG-26-C31N* G-26-C31N* GCG-26-C231N* GCG-26-CA31N* *G,I,M,7,J plug Instruction Manual Manual is for the following

More information

User, Installation and Servicing Instructions. Panther Static Hot Cupboards G1, G2 and G3 IS86 ECN1881

User, Installation and Servicing Instructions. Panther Static Hot Cupboards G1, G2 and G3 IS86 ECN1881 User, Installation and Servicing Instructions Panther Static Hot Cupboards G1, G2 and G3 Panther Static Hot Cupboard User Instructions Installation Remove all packaging and protective coatings from both

More information

Optimax Refrigerated Retail Merchandisers

Optimax Refrigerated Retail Merchandisers V Optimax Refrigerated Retail Merchandisers MODEL NUMBERS RMR65E RMR100E RMR130E RMR65S RMR100S RMR130S RMR65SW RMR100SW RMR130SW Assisted service 650 wide Assisted service 1000 wide Assisted service 1300

More information

Installation Instructions & Operating Manual IMPORTANT

Installation Instructions & Operating Manual IMPORTANT Installation Instructions & Operating Manual IMPORTANT These instructions should be read carefully and retained for future reference TABLE OF CONTENTS SECTION 1: WARNINGS & ELECTRIC SPECIFICATIONS 1.1

More information

Up to 60 Pint Commercial Grade DEHUMIDIFIER

Up to 60 Pint Commercial Grade DEHUMIDIFIER OWNER S MANUAL Up to 60 Pint Commercial Grade DEHUMIDIFIER Product #700834 IMPORTANT: After unpacking (or accidental tip-over) allow dehumidifier to stand upright for 20 minutes before starting. Contents

More information

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE OPERATING MANUAL AIR CONDITIONER Duct Type Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH KEEP THIS MANUAL FOR FUTURE REFERENCE PART NO. 9374379583 CONTENTS SAFETY PRECAUTIONS... 2 FEATURES AND FUNCTIONS...

More information

Health & Safety and Installation guide

Health & Safety and Installation guide Health & Safety and Installation guide EN ENGLISH Health and Safety guide... 3 Installation guide... 6 2 SAFETY INSTRUCTIONS EN IMPORTANT TO BE READ AND OBSERVED Before using the appliance carefully read

More information

UPUTSTVO ZA RAD USER INSTRUCTIONS GEBRAUCHSANWEISUNG ИНСТРУКЦИЯ ПО ЭКСПЛУАТАЦИИ И СОДЕРЖАНИЮ

UPUTSTVO ZA RAD USER INSTRUCTIONS GEBRAUCHSANWEISUNG ИНСТРУКЦИЯ ПО ЭКСПЛУАТАЦИИ И СОДЕРЖАНИЮ OPREMA-UREĐAJI d.d. Ludbreg is the only manufacturer of dispensing and cooling units for beer, wine, water, soda-water and soft drinks in Croatia. In November 1998 the company was awarded the certificate

More information

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1 DUCTED AIR CONDITIONER Owner s Manual KD Series KD24 Kaden Owner s Manual 1 Table of Contents 1. Safety Precautions 4 2. Indoor Unit Parts and Major Functions 6 3. Care and Maintenance 8 4. Troubleshooting

More information

4L Instant Water Boiler Instructions for Use

4L Instant Water Boiler Instructions for Use Power Details: 220-240Va.c. 50Hz-60Hz 2200-2600W Capacity: 4.0L Accessories: 2 Water aid trays Water Filters are not included and can be purchased separately Item Code 10747 IMPORTANT NOTES FOR YOUR INSTANT

More information

installation & operating instructions

installation & operating instructions installation & operating instructions RGE 410 RA/RM-2D 822706106 MO-M 0740 INTRODUCTION We are pleased that you have chosen this refrigerator and hope you will derive much satisfaction from using it.

More information

MeacoDry ABC Range Dehumidifiers

MeacoDry ABC Range Dehumidifiers MeacoDry ABC Range Dehumidifiers Thank you for choosing Meaco, we really do appreciate it INSTRUCTION MANUAL [EN] MeacoDry ABC range SAFETY INFORMATION ATTENTION This dehumidifier must not be used in rooms

More information

Installation guide Billi B-3000 Sparkling Dual levered slimline tap option

Installation guide Billi B-3000 Sparkling Dual levered slimline tap option Installation guide Billi B-3000 Sparkling Dual levered slimline tap option Installation requirements. IMPORTANT: This Billi appliance is to be installed by a licensed trades person in accordance with AS/NZS

More information

CRU-S Series Stainless Steel Condensate Recovery Unit

CRU-S Series Stainless Steel Condensate Recovery Unit IM-UK-CRU-S UK Issue 1 CRU-S Series Stainless Steel Condensate Recovery Unit 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Storage, shutdown and equipment protection

More information

PC71 American Style Fridge Freezer

PC71 American Style Fridge Freezer PC71 American Style Fridge Freezer Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu

More information

CREMALDI Cream machines Operating instructions

CREMALDI Cream machines Operating instructions Vaihinger GmbH Horstweg 29 65520 Bad Camberg-Erbach Telefon 0 64 34 / 94 05 0 Telefax 0 64 34 / 94 05 99 http://www.sanomat.com info@vaihinger.com CREMALDI Cream machines Operating instructions CONTENTS

More information

OPERATING INSTRUCTIONS FOR LEEC AUTOMATIC CO2 INCUBATORS. MODELS GA2000 and GA2010 MODELS GA3000 and GA3010 With Infrared CO2 detectors CONTENTS

OPERATING INSTRUCTIONS FOR LEEC AUTOMATIC CO2 INCUBATORS. MODELS GA2000 and GA2010 MODELS GA3000 and GA3010 With Infrared CO2 detectors CONTENTS OPERATING INSTRUCTIONS FOR LEEC AUTOMATIC CO2 INCUBATORS MODELS GA2000 and GA2010 MODELS GA3000 and GA3010 With Infrared CO2 detectors CONTENTS 1.0 GENERAL DESCRIPTION 2.0 INSTALLATION AND SETUP 3.0 DESCRIPTION

More information

600 / 400 / 150 litre series Refrigerators/Freezers Instruction manual

600 / 400 / 150 litre series Refrigerators/Freezers Instruction manual 600 / 400 / 150 litre series Refrigerators/Freezers Instruction manual Models: CD080-A/CD081-A/CD082-A/CD083-A/CD084-A/CD085-A/CD610-A/CD611-A/ CD612-A/CD613-A/CD614-A/CD615-A/CD086-A/CD087-A/CD088-A Telephone

More information

Chest Freezer Instruction manual

Chest Freezer Instruction manual Chest Freezer Instruction manual Model CE210-A / CE211-A / CE212-A Telephone Helpline: 1300 225 960 Safety Tips Position on a flat, stable surface. A service agent/qualified technician should carry out

More information

Operating instructions

Operating instructions Operating instructions For the operator Operating instructions HOME SYSTEM GB, IE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Tel. +49 21 91 18 0 Fax +49 21 91 18 28 10 info@vaillant.de

More information

FELIX STORCH, INC. SUMMIT APPLIANCE DIVISION

FELIX STORCH, INC. SUMMIT APPLIANCE DIVISION FELIX STORCH, INC. SUMMIT APPLIANCE DIVISION INSTRUCTION MANUAL FOR MODEL: FFAR-10 Thank you for your trust and for buying this appliance. It s designed to refrigerate your fresh foods, while adding an

More information

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N OPERATING MANUAL AIR CONDITIONER DUCT TYPE ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9374379293-02 CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS... 2 PREPARATORY OPERATION...

More information

A few simple steps to ensure perfect water, every time.

A few simple steps to ensure perfect water, every time. A few simple steps to ensure perfect water, every time. Use and Care Guide MODELS: A8CTBOTTLELESSWHT A8CTBOTTLELESSBLK Registration Please visit the website below to register your new water cooler within

More information

16 XD Mk2 Inset Electric Fire

16 XD Mk2 Inset Electric Fire 16 XD Mk2 Inset Electric Fire B-1005344 Packing Checklist Electric Fire Remote Control Handset 2 x AAA Batteries Log Set Ember Ice Crystal Set Instruction Manual Fascia IMPORTANT PLEASE READ THESE INSTRUCTIONS

More information

V 120 SG - V 160 SG. Instructions for use

V 120 SG - V 160 SG. Instructions for use V 120 SG - V 160 SG Instructions for use Warning As the appliance contains a flammable refrigerant, it is essential to ensure that the refrigerant pipes are not damaged. The quantity and type of the refrigerant

More information

FW422. Integrated In Column Larder Fridge. Installation, use and maintenance.

FW422. Integrated In Column Larder Fridge. Installation, use and maintenance. FW422 Integrated In Column Larder Fridge Installation, use and maintenance www.cda.eu Contents: 3 Important information 5 Important safety warnings 6 Before first use 7 Setting the temperature 7 Guidance

More information

LEC L6014W/S User Manual

LEC L6014W/S User Manual LEC L6014W/S User Manual Safety Information Important Please read these instructions fully before installation Before use The installation of this appliance is best carried out by 2 people. Dispose of

More information

Glass Washer. PERLICK Glass Washer NO ONE WORKS HARDER TO KEEP YOU COOKING. WHALEY FOODSERVICE REPAIRS ITEM PART NO. NO.

Glass Washer. PERLICK Glass Washer NO ONE WORKS HARDER TO KEEP YOU COOKING. WHALEY FOODSERVICE REPAIRS ITEM PART NO. NO. Glass Washer PERLICK Glass Washer 1 50567 Glasswasher Control 2 52536 Spray Arm Drive Motor 3 50445 Wash Pump 4 52528 Pump Motor Capacitor 5 52652-1 Water Inlet Valve 6 52669-1 Band Heater 7 52626A-B Rinse

More information

CONGRATULATIONS ON CHOOSING THE WATERLOGIC 4 FIREWALL YOUR WATERLOGIC WATER DISPENSER

CONGRATULATIONS ON CHOOSING THE WATERLOGIC 4 FIREWALL YOUR WATERLOGIC WATER DISPENSER User Manual CONGRATULATIONS ON CHOOSING THE WATERLOGIC 4 FIREWALL Thank you for choosing the Waterlogic 4 Firewall, the advanced water dispenser. All Waterlogic products are designed to deliver pure refreshing

More information

Power Pack Service Manual

Power Pack Service Manual Power Pack Service Manual MMPP4301-EP MMPP4301 MMPP4301-WC MMPP4301-PKG MMPP4301-PKG-WC MMPP4302 MMPP4302-WC MMPP4302-PKG MMPP4302-PKG-WC MMPP4303-PKG MMPP4303-PKG-WC MMPP4303-PKG-3 MMPP4305-PKG MMPP4305-PKG-WC

More information