1 C O M M E R C I A L A N D I N D U S T R I A L V E N T I N G Model IVSI Positive Pressure Venting Systems Ideal for discharging exhaust gases and fumes from boilers, heaters, ovens, engines, turbines and kitchen appliances NEW! Model IVSI-4ZC Offers Zero Clearance to Combustibles Available in 1", 2", or 4" insulation
2 Model IVSI Venting Increases usable floor space. Offers the lowest clearance to combustibles in the industry, as listed by UL/ULC. Your choice of 1", 2", or 4" insulated components. Many Applications AMPCO s ceramic-insulated and sealed exhaust systems are ideal for discharging exhaust gases and fumes from boilers, heaters, ovens, engines, turbines, and kitchen appliances. Reduces Skin Temperature AMPCO insulated chimneys are UL/ULC-listed and will accommodate flue gases at temperatures not exceeding 1800 F intermittent operation and up to 1400 F continuous operation. Grease duct applications will accommodate flue gases at temperatures not exceeding 500 F continuous. AMPCO insulated venting saves on cooling bills because it reduces ambient temperatures in boiler and engine rooms. AMPCO s insulated venting is interchangeable with all AMPCO stack components. You can insulate sections only as required. Furthermore, AMPCO insulated venting increases usable floor space because it reduces clearance to combustibles and noncombustible materials. You maximize floor space and reduce building heat gain. Full Product Line AMPCO chimneys are available in diameters from 6" through 48". You have a choice of 1", 2", or 4" insulated thickness. Fittings include: Variable lengths 90 manifold tees 45 lateral tees Wyes 15, 30, 45, and 90 elbows Support pieces Termination components Adapters Expansion joints Sealants Lightweight, interchangeable and easy to install AMPCO insulated components are so light and easy to install that 1 or 2 people can easily assemble them without special equipment. No welding or onsite fabrication is required. Components are interchangeable, allowing complex systems to be assembled from standard elements. This means modifications, additions or repairs can be made quickly and economically. Furthermore, AMPCO furnishes detailed drawings and easy-tofollow instructions. This reduces installation time and assures a safe installation. AMPCO ceramic-insulated venting reduces skin temperature. AMPCO 484 N. THOMAS DRIVE BENSENVILLE, IL TEL: (630) FAX: (630) Copyright, October, 2007, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved. All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances. 6
3 Model IVSI Venting Professional Engineering and Technical Support AMPCO engineers have many years of experience. This is why they can help you design a complete venting system, whether your system is very simple or complex. All you need to furnish is the basic information. (See Design Checklist on page 3.) We ll perform all sizing calculations, provide submittal CAD drawings, and furnish a bill of materials for the total system designed to your specifications. Chances are the AMPCO system can be installed at far less cost than conventional onsite construction methods. Labor savings can be as much as 50% or more! When you work with AMPCO, you deal with a company that is known for quick product delivery, quality components, and excellent customer service. That s not just a promise. It s our guarantee! Quality Construction and 10-Year Factory Warranty AMPCO insulated venting is built to last for years. Inner walls are constructed of 304 or optional 316 stainless steel. Type 316 stainless is recommended for high sulphur fuels and/or corrosive environments. All pipes and fittings are continuous seam-welded and pressure tight. Wide-end flanges provide a strong, virtually leak-proof joint. Containment and closure bands resist slippage from vibration or thermal expansion because they are deeply flanged and channeled. 1" Ceramic-Insulated Venting 2" 4" AMPCO 484 N. THOMAS DRIVE BENSENVILLE, IL TEL: (630) TEL: (630) FAX: (630) FAX: (630) Copyright, October, 2007, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved. All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.
4 Model IVSI - Assembly Many Exclusive Features Fast, on site assembly. No need for welding or special tools! AMPCO insulated elements simplify on-site installation. Components are joined together with a Containment Band that is fitted over the butted flanges of the adjoining inner wall and bolted in place. No welding is necessary. A Closure Band is then fitted over the outer wall and bolted in place. Hangers, Wall Supports, and other accessories are just as easy to install. 3. Fill the channel of the flanged band with proper sealant Apply a continuous bead of the proper sealant to one of the flanges to be joined. Join the two flanged ends of the pipe sections together. Install flange band around flanges. Install insulation strips to ensure all air gaps are filled. Secure the outer casing with the Closure Band. Check to make sure pieces are secure and air tight. AMPCO s patented spacers, a tighter fit and quieter operation AMPCO s patented spacer separates the walls of the AMPCO positive pressure insulated components. These patented spacers virtually eliminate insulation voids and hot spots. Spacers strengthen stability and provide a stronger base for the closure band. This results in extra strength, tighter fit, and quieter operation. AMPCO s sealants, a virtually leak-free joint AMPCO s VS 600 sealant is used for outer wall weather-proofing and for particle containment only. AMPCO s VS 2000 sealant is for all-temperature inner wall joint requirements. AMPCO 484 N. THOMAS DRIVE BENSENVILLE, IL TEL: (630) FAX: (630) Copyright, October, 2007, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved. All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances. 8
5 Product Information Chart Description Applications Fuel Types Exhaust Pressure Exhaust Temperature Listings Diameters Materials Double-wall either 1", 2", or 4" material insulated Boiler and chimney systems, engine/turbine exhausts, grease/oven exhausts, air/particle containment LP; natural gas; #2, #4*, #5* & or #6* fuel oil; wood; grease vapors; caustic fumes*; (*recommend 316 stainless steel containment) Positive, neutral or negative 1000 F continuous, 1400 F intermittent 1400 F continuous, 1800 F intermittent Grease Duct 500 F continuous 6" through 48" Exception: Model 4ZC, 6" through 36" Inner:.035" 20 ga 304SS standard (optional.035" 20 ga 316SS available) Outer:.025" 24 ga aluminized 6" to 24".034" 20 ga aluminized steel 26" to 48" (optional 304 or 316SS available) Insulation Eight-pound density ceramic insulation of 1", 2", or 4" thickness Clearances to Combustibles (unenclosed chimney) IVSI- 4ZC inches IVSI-1" IVSI-2" and IVSI-4" Dia. Grease Duct Dia F 1400 F Grease Duct Dia F 1400 F Grease Duct ½ ½ ½ ½ ½ ½ ½ Clearances to Noncombustibles inches ½" or distances required to allow for proper installation and maintenance inches AMPCO 484 N. THOMAS DRIVE BENSENVILLE, IL TEL: (630) TEL: (630) FAX: (630) FAX: (630) Copyright, October, 2007, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved. All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.
6 Model IVSI Installations Typical boiler stack installation using IVSI Ability to reduce clearances to one-half inch. Greatly reduces clearance requirements of welded steel and those of competitive products, while providing a safer environment. Saves on cooling bills by reducing appliance-radiated exhaust heat. Agency-listed for temperatures up to 1000 F continuous, 1400 F intermittent and 1400 F continuous, 1800 F intermittent. Interchangeable with all other AMPCO positive pressure components. Material or air-insulated components can be integrated to achieve desired results within a single exhaust system. Typical diesel engine exhaust installation using IVSI Reduced skin temperatures mean less risk of personal injury. Reduced skin temperatures result in reduced clearances to combustibles, the best in the industry. Provides minimum exhaust back pressure for maximum performance. AMPCO will design, at no charge, an exhaust system that will allow for thermal expansion, as well as increasing engine and exhaust system life. Agency-listed for temperatures up to 1000 F continuous, 1400 F intermittent and 1400 F continuous, 1800 F intermittent. AMPCO 484 N. THOMAS DRIVE BENSENVILLE, IL TEL: (630) FAX: (630) Copyright, October, 2007, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved. All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances. 10
7 Model IVSI Installations Typical grease duct installation using an insulated IVSI venting system Reduces risk of fires by providing a tough insulated barrier. Reduced clearances mean more available space. Allows for thermal expansion under severe conditions. Capabilities for automatic wash-down and fire detection/prevention systems. Grease traps control grease-laden vapors, which reduces risk of grease fires. Complete agency certification for exhaust temperatures 500 F to 2000 F. Interchangeable with other insulated and noninsulated AMPCO components. Hood Hood The Advantages of Insulated Venting 1. Your choice of 1", 2", or 4" insulated components. 2. Reduces skin temperature for a safer environment. 3. Saves on cooling bills by reducing ambient temperature in kitchens and in engine and boiler rooms. 4. Interchangeable with all AMPCO stack components. Use insulated sections only as required. 5. Increases usable floor space and reduces clearance to combustible and noncombustible material. 6. Reliable; UL- and/or ULC-listed. Model 4ZC is UL-listed only. AMPCO 484 N. THOMAS DRIVE BENSENVILLE, IL TEL: (630) TEL: (630) FAX: (630) FAX: (630) Copyright, October, 2007, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved. All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.
FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS
CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-08 Listing No. MH26687 Testing No. 11EN
More informationCorr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.
CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-1995 Listing No. MH26687 Testing No. 11EN
More informationSMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD
CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-08 Listing No. MH26687 Testing No. 11EN
More informationC. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.
SECTION 235100 - BREECHINGS, CHIMNEYS, AND STACKS PART 1 GENERAL 1.1 SECTION INCLUDES A. Fabricated breechings. B. Manufactured chimneys for gas fired equipment. C. Manufactured double wall chimneys for
More informationForced Draft Boiler Flue Gas Venting: Problems & Solutions. Presented by Steve Connor and Patrice Gouin January 27, 2016
Forced Draft Boiler Flue Gas Venting: Problems & Solutions Presented by Steve Connor and Patrice Gouin January 27, 2016 What Will We Be Covering Today? Pressurized Non-condensing Vent Systems Venting s
More informationDirect Vent Training & Installation Instructions for Venting 40/50 gallon models Telescoping Vent Kit (standard)
Choosing Location of the water heater This water heater is of the direct vent design. It takes all of its fresh air for combustion from outside the building which it is installed. It also vents the combustion
More informationSECTION DUCTWORK
PART 1 GENERAL 1.1 REFERENCES SECTION 23 31 00 DUCTWORK A. ASHRAE - Handbook, Duct Design B. ASHRAE - Handbook, Duct Construction C. ASTM A90/A90M - Standard Test Method for Weight (Mass) of Coating on
More informationApplicable codes and standards provide
For many years, duct products have often involved significant on-site measurement and construction, bringing certain advantages and risks. Here, that practice is compared to the use of listed ductwork,
More informationInstallation Instructions
Installation Instructions Type B Gas Vent Model E/R 3" 8" ECCO TYPE B GAS VENT AND ACCESSORIES ARE FOR USE ONLY WITH LISTED CATEGORY 1 GAS-FIRED APPLIANCES OR APPLIANCES LISTED FOR USE WITH TYPE B GAS
More informationSECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.
SECTION 15890 DUCTWORK PART 1 - GENERAL 1.1 SECTION INCLUDES A. Metal ductwork. B. Duct cleaning. 1.2 RELATED SECTIONS A. Section 09900 - Painting: Weld priming, weather resistant, paint or coating. B.
More informationEXCEL. ULTRABlack THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY NEVER EVER BUY ANOTHER STOVE PIPE
THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY ULTRABlack NEVER EVER BUY ANOTHER STOVE PIPE Chimney To determine what parts you need for your woodstove installation, try the
More informationVenting of Gas Fired Equipment RV
PLEASE DO NOT BOOKMARK ANY ANYTIMECE WEBPAGES! Our system will remember the last page you viewed when logging out and back in but please DO NOT exit out when taking a test. Your place will NOT be saved.
More informationZ-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS
Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS 3 & 4 SPECIAL STAINLESS STEEL VENTING SYSTEM FOR GAS BURNING APPLIANCES CATEGORY I, II, III, & IV TESTED AND LISTED BY UNDERWRITERS
More informationLombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS
Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS (630) 620-5750 Fax: (630) 629-2374 www.villageoflombard.org COMMERCIAL HOOD & DUCT SYSTEM PLAN REVIEW REQUIREMENTS International
More informationCHAPTER 8 CHIMNEYS AND VENTS
CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.
More information2015 MECHANICAL CODE REQUIREMENTS
2015 MECHANICAL CODE REQUIREMENTS ANTRIM COUNTY BUILDING DEPARTMENT PO BOX 188 205 CAYUGA STREET BELLAIRE, MI 49615 (231) 533-8373 FAX (231) 533-6041 Mechanical requirements for residential buildings per
More informationCQS POWER VENT. General. Venting Requirements. Venting Instructions PREEVA Indoor, Power-Vented Heater Model PDH
Applies to: Form I-PDH-V Venting Instructions PREEVA Indoor, Power-Vented Heater Model PDH CUSTOMER AGENCY PROCESS CQS CONVERGENT QUALITY SYSTEM PRODUCT WARRANTY START-UP Power-Vent Indoor Model PDH General
More informationANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution.
NY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution. Specialists in Flexible Z-FLEX has been providing flexible
More informationCHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2012 EDITION
CHAPTER 23.20 LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2012 EDITION Sections 23.20.100 Local amendments to the International Mechanical Code, 2012 Edition.... 2 23.20.101.2 Scope.... 2 23.20.103-110
More informationFundamentals of Making Energy-Saving and Cost-Efficient Boiler Exhaust Systems Design Solutions and Applications
Fundamentals of Making Energy-Saving and Cost-Efficient Boiler Exhaust Systems Design Solutions and Applications ASHRAE Qatar Oryx Chapter 10 th November 2012 Presenter: Steen Hagensen Make the unimaginable
More informationPOWER VENT. Standard Power Vent, Fan Type Unit Heaters: Standard Power Vent, Blower Type Unit Heaters: General WARNING WARNING. Model UDAP & Model APD
General APPLIES TO: Standard Power Vent, Fan Type Unit Heaters: Model UDAP & Model APD Standard Power Vent, Blower Type Unit Heaters: Model UDBP Form I-UD&APD Series-V-PV (05-17) Obsoletes I-UD&APD Series-V-PV
More informationThe intelligent alternative for flue gas venting systems
The intelligent alternative for flue gas venting systems FIRST LISTED InnoFlue is the first polymeric vent system tested and listed to ULC-S636 and UL-1738 in North America Intelligent for a good reason
More informationGas-Fired Unit Heaters Commercial & Industrial
6-107.10 February, 2005 Gas-Fired Unit Heaters Commercial & Industrial GRAVITY VENTED PD, BD POWER VENTED PDP, BDP, HD SEPARATED COMBUSTION PSH, BSH, HDS GAS-FIRED, GRAVITY-VENTED UNIT HEATERS Low Initial
More informationENERVEX VHX VORTEX HEAT RECOVERY CENTER
ENERVEX VORTEX HEAT RECOVERY CENTER 3002603 06.16 Installation & Operating Manual READ AND SAVE THESE INSTRUCTIONS! ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P: 770.587.3238 F:
More information2012 INTERNATIONAL FUEL GAS CODE VENTS
2012 INTERNATIONAL FUEL GAS CODE SECTION 502 (IFGC) VENTS 502.1 General. All vents, except as provided in Section 503.7, shall be listed and labeled. Type B and BW vents shall be tested in accordance with
More informationSPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT
CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT SECTION 901 GENERAL 901.1 Scope. This chapter shall govern the approval, design, installation, construction, maintenance, alteration
More informationCHIMNEYS AND VENTS CHAPTER 8
CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.
More informationBeneficial Use of Landfill Gas for Leachate Evaporation and Power Generation
Beneficial Use of Landfill Gas for Leachate Evaporation and Power Generation Efficient use of Energy Turning waste to energy, liabilities to assets and visions into reality. Table of Contents BENEFICIAL
More informationTW-Pro. Twin Wall Insulated Flue System EN T600 N1 W V2 L50040 G50 / O40
TW-Pro Twin Wall Insulated Flue System EN1856-1 T600 N1 W V2 L50040 G50 / O40 Approvals TW-Pro Twin Wall Insulated Flue System - TW-Pro has been specifically designed with the installer in mind with a
More informationPellet Stove. Flex Pipe. Appliance Connector
Installation Instructions & Owners Maintenance Guide DT-M Direct-Temp for Multi Fuel L-Vent / Vent System for Pellet, Corn and other Bio-Fuel Burning Appliances Introduction Direct-Temp for Multi-Fuel
More informationRSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2
3002239 RSIF 2014-04-04 Installation and operation manual RSIF power venter READ AND SAVE THESE INSTRUCTIONS! Product information Chapters 1 + 2 Mechanical installation Chapter 3 Electrical installation
More informationSingle Wall Flue system. Installation manual WARNING. Installation Manual CoxDENS PPs MC-CG-105 EN_892054
MC-CG-105 EN_892054 WARNING Installation Manual CoxDENS PPs Incorrect installation of Flue System and Components, or failure to follow installation instructions, can result in property damage or serious
More informationGWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions
GWS Gas-Fired Water Boilers Venting Manual Hazard definitions Contents Page Hazards that will cause severe personal injury, death or substantial property damage. Hazards that can cause severe personal
More informationTYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES
INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES LISTED TO ULC-S609 & UL641 A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES
More informationEngine Exhaust Boiler Stack Grease Duct Gas and Oil Vents Chimney Liner
All-in-One Piping System Positive Pressure Exhaust Systems up to 90-inch water column Models SWKL & SWFL - Single Wall Models DWKL & DWFL - Double Wall Air & Fiber Insulation Installation Instructions
More informationUNI-STACK An enterprise of United McGill Corporation Founded in 1951 U.L. LISTED CHIMNEY, BREECHING, and GREASE DUCT SYSTEMS
United McGill products UNI-STACK An enterprise of United McGill Corporation Founded in 1951 U.L. LISTED CHIMNEY, BREECHING, and GREASE DUCT SYSTEMS a McGill AirFlow product UNI-STACK DUCTWORK McGill AirFlow
More informationBUDERUS. Superior Equipment by Design. Comfortable. Efficient. Intelligent Heating. BUDERUS. G Cast Iron Commercial Boilers
BUDERUS BUDERUS G1 1 1 G1 G1 G1Boilers Cast Iron Commercial High Efficiency Combustion Efficiencies Up to 88.2% 0 to,982 MBH Output Thermostream Design Eliminates Thermal Shock Superior Equipment by Design
More informationInstallation Instructions Remote Blowers
Installation Instructions Remote Blowers Models: REMP3, REMP16 Suitable for use in a household cooking area. Suitable for use with solid state controls. To complete this blower, a Dacor hood assembly or
More informationAqua Balance. Direct Exhaust Venting Kit Instructions
Aqua Balance WMB-155H and WMB-155C Wall Mount Gas-Fired Heating Only Boiler & Combination Boiler Heating and Domestic Hot Water Direct Exhaust Venting Kit Instructions AquaBalance TM WMB-155H & WMB-155C
More informationFAN ENGINEERING. Sealing of Fan Housings
FAN ENGINEERING Information and Recommendations for the Engineer FE-700 Sealing of Fan Housings Introduction A variety of options are offered by fan manufacturers to seal fan housings. Sealing the housing
More informationULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER
www.weil-mclain.com ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER Water Natural/Propane Gas 80-399 MBH Direct Exhaust/Direct Vent Average Efficiency 94% AFUE HIGH EFFICIENCY CONDENSING BOILER The new
More informationMechanical Appliance and Equipment Inspection Checklist
34 2015 IRC Performing Residential Mechanical s Mechanical Appliance and Equipment Checklist Inspect Mechanical Appliance and Equipment Comments / I. Identify possible mechanical appliance and equipment
More informationSEPARATED COMBUSTION. General WARNING
Form I-UD-V-SC (09-17) Obsoletes Form I-UD-V-SC (Version 05-17) APPLIES TO: Venting Requirements for Model UDAS and Model UDBS and Instructions for Combustion Air Inlet / Vent Terminal Options CC6 and
More informationDo not use this vent pipe or fittings for venting incinerators of any kind.
! CAUTION! Do not use this vent pipe or fittings for venting incinerators of any kind. C.S.A. Certified For Natural Gas Or Propane Tested For 100 LBS. ASME Working Pressure For correct installation of
More informationDuraPlus HTC. All-fuel, double-wall chimney system. ULC S629.
DuraPlus HTC ll-fuel, double-wall chimney system. ULC S629. Specifications pplications DuraPlus HTC is a double-wall, all-fuel chimney system for both the U.S. and Canada for use with wood stoves; fireplaces;
More informationTechnical Datasheet. FHG-S Models 28, and 45. Benefits at a Glance: State Route 22 Salem, NY 12865
FHG-S Models 28, and 45 Technical Datasheet FrÖling FHG-S The FHG-S is a patented, wood-fired gasification boiler available in two sizes with outputs from 102,500-153,500 Btu/hr. Benefits at a Glance:
More informationSPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT
CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT SECTION 901 GENERAL 901.1 Scope. This chapter shall govern the approval, design, installation, construction, maintenance, alteration
More informationCHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL BURNING EQUIPMENT
CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL BURNING EQUIPMENT SECTION 901 GENERAL 901.1 Scope. This chapter shall govern the approval, design, installation, construction, maintenance, alteration
More informationULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER HIGH EFFICIENCY CONDENSING BOILER
ULTRA www.weil-mclain.com SERIES 4 HIGH EFFICIENCY CONDENSING BOILER Water Natural/Propane Gas 80-399 MBH Direct Exhaust/Direct Vent Average Efficiency 94% AFUE HIGH EFFICIENCY CONDENSING BOILER The new
More informationMighty Venter Power Vent System
Installation and Operation Instructions Document 7008B Installation and Operation Instructions for Mighty Venter Power Vent System Models MV2, MV3, MV4, and MV5 for Mighty Therm Sizes 500-1825 FOR YOUR
More informationASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)
ASSEMBLY INSTRUCTIONS - NXS SERIES OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED RADIANT
More informationCHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2000 EDITION
CHAPTER 23.20 LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2000 EDITION SECTIONS 23.20.100 Local Amendments To The International Mechanical Code, 2000 Edition 23.20.202 Definitions 23.20.301.14
More informationTechnical Guidance CE Marking of Metal Chimneys and Flues
CE Marking of Metal Chimneys and Flues Steel Chimney Programme Schiedel is the leading producer of ceramic chimney systems in Europe, and are now regarded as the market leaders in prefabricated stainless
More informationSECTION (15820) - AIR DUCT ACCESSORIES
PART 1 GENERAL 1.01 SUMMARY A. Section includes: SECTION 23 33 00 (15820) - AIR DUCT ACCESSORIES 1. Manual-Volume Dampers 2. Fire Dampers 3. Turning Vanes 4. Duct-Mounted Access Doors 5. Flexible Connectors
More informationICC Model VIC SINGLE WALL SPECIAL GAS VENT INSTALLATION AND MAINTENANCE INSTRUCTIONS
ICC Model VIC SINGLE WALL SPECIAL GAS VENT INSTALLATION AND MAINTENANCE INSTRUCTIONS The ICC Model VIC is a listed venting system designed for venting commercial and industrial appliances, condensing appliances,
More informationMFC Series Boiler Vent and Combustion Air Guide
Pre-Installation Application Guide MFC Series Boiler Vent and Combustion Air Guide Applies to Models 3000 through 10000 Exhaust venting, combustion air and piping Requirements for MFC Series boilers Other
More informationUp to 98% Thermal Efficiency CONDENSING COMMERCIAL GAS WATER HEATERS CONTROL WITH CASCADING SEQUENCER UP TO 98% THERMAL EFFICIENCY
CONDENSING COMMERCIAL GAS WATER HEATERS CONTROL WITH CASCADING SEQUENCER UP TO 98% THERMAL EFFICIENCY 8 MODELS FROM 150,000 TO 800,000 BTU/HR 5:1 TURNDOWN FIRING RATE LESS THAN 20 ppm NOx Up to 98% Thermal
More informationInstallation & Maintenance Instructions
Installation & Maintenance Instructions Listed & Tested to UL641, ULC-S609, ULC/ORD C441 AMERIVENT Model PVP Pellet Pipe Plus Vent Connector for Pellet-Fuel Appliances and Other Low-Temperature Applications
More informationCHAPTER 8 CHIMNEYS AND VENTS
CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.
More informationCHAPTER 5: EXHAUST SYSTEMS
MOTORS, FANS AND FILTERS 503.1 General. Motors and fans shall be sized to provide the required air movement. Motors in areas that contain flammable vapors or dusts shall be of a type approved for such
More informationTRIAD Boiler Systems, Inc Atlantic Drive, Unit 2 West Chicago, IL
TRIIUMPH SERIIES AIIR SUPPLY AND VENTIING GUIIDE C.S.A Design-Certified Complies with ANSI Z21.13/CSA 4.9 Gas-Fired Low Pressure Steam & Hot Water Boilers ASME Code Section IV C.S.A Design-Certified Complies
More informationANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution.
ANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution. Specialists in Flexible Z-FLEX has been providing flexible
More informationSEPARATED COMBUSTION WARNING
CUSTOMER AGENCY PROCESS CQS CONVERGENT QUALITY SYSTEM PRODUCT WARRANTY START-UP Form I-SDH-V (Version.5) Obsoletes I-SDH-V (Version.4) Vent Installation Applies to: Venting Requirements for PREEVA Separated-Combustion
More informationColumbia Boiler Company
EMG Series Boilers Available in Natural Gas & Propane Rev 12012 Columbia Boiler Company PO Box 1070 Pottstown, PA 19464 Tel (610) 473-8457 Fax (610) 367-6800 Website www.columbiaboiler.com Email cbcsales@ptd.net
More informationAdvanced Venting Systems
Advanced Venting Systems 1 Z-Vent Special Gas Vent 3 Flexible Vent Connector Systems 5 Aluminium Chimney Liner System 7 Stainless Steel Chimney Liner System 9 Oval Liner System / Advancing the Industry
More informationInternet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #
INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #238-39387-00 THIS INSTRUCTION SUPPLEMENT IS ONLY INTENDED TO GIVE INSTALLATION INSTRUCTIONS AND INFORMATION RELATED TO THE INDUCED
More informationA TRUE GAME CHANGER - The Vortex Heat Recovery Center CONDENSING EFFICIENCIES FOR TRADITIONAL BOILERS & HEATERS
A TRUE GAME CHANGER - The Vortex Heat Recovery Center CONDENSING EFFICIENCIES FOR TRADITIONAL BOILERS & HEATERS Flexibility and Performance - Unlike any other Heat Recovery System FEATURES Exceptional
More information4.3 Installing Appliances and Interior Vapor Distribution Systems Performance-Based Skills Assessment 2016
4.3 Installing Appliances and Interior Vapor Distribution Systems Performance-Based Skills Assessment 2016 Section One Task 1 Task 2 Task 3 Task 4 Task 5 Section Two Task 1 Task 2 Task 3 Task 4 Task 5
More information90% Efficiency without Boiler Replacement TRUE GREEN SOLUTIONS NEW. Patent Pending. EcoFlex 90 + System Modulating Fan-Powered Economizer
without Boiler Replacement TRUE GREEN SOLUTIONS NEW Patent Pending EcoFlex + System Modulating Fan-Powered Economizer EcoFlex + System Because They Are Your Btus EcoFlex + System - a packaged modulating
More informationUNDERSTANDING SAFETY CABINETS
UNDERSTANDING SAFETY CABINETS Why use safety cabinets? What makes a safety cabinet safe? How to choose the right safety cabinet Reduce fire risks and safely organize, segregate, and store flammable fuels,
More informationSTS-JZ (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS
SUBMITTAL DATA (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS PROJECT: ENGINEER: CONTRACTOR: DISTRIBUTOR: SCHWANK MODEL #: FUEL: APPROVED BY: DATE: APPROVAL #: 1 Submittal NOTICE:
More informationBoiler Venting. Definitions, Theory and Applications. Presented by: Jason Geagan, National Sales Manager US Draft Co Fort Worth, TX
Boiler Venting Definitions, Theory and Applications Presented by: Jason Geagan, National Sales Manager US Draft Co Fort Worth, TX Gas Appliance Listings ANSI Z21 - Categorized Appliances Gas fired low
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS FACTORY BUILT CHIMNEY CONNECTOR A MAJOR CAUSE OF CHIMNEY CONNECTOR RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE
More informationThe Only Gas Furnaces Made in Canada napoleonheatingandcooling.com
9700 SERIES TWO-STAGE VARIABLE SPEED ULTRA HIGH EFFICIENCY GAS FURNACES The highest efficiency two-stage furnace on the market available up to 97.1% AFUE The Only Gas Furnaces Made in Canada napoleonheatingandcooling.com
More informationINSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT
C US This manual must be left with owner and should be hung on or adjacent to the boilerfor reference. COMMON VENTING MODELS CHS-300 through CHS-399 INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS
More informationEasy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation
Easy to assemble Silicone gasket sealed Laser-welded seams Smooth joint connections 360 Lock-Tab secure rotation Evenly spaced inner and outer pipes Continuous column of air insulation Ultimate Pellet
More informationSECTION DUCTWORK
SECTION 15890 DUCTWORK PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 07270 - Firestopping and Fire and Smoke Barrier Caulking. 2. 15260 - Vibration Isolation. 3. 15280 - Thermal Insulation (HVAC).
More informationThe Ultimate in Pizza Baking Variable speed Black granite stone conveyor belt Turbo-Flex Airflow System
PICARD S Tunnel Oven LP-200 Get ahead of all your competitors! The Ultimate in Pizza Baking Variable speed Black granite stone conveyor belt Turbo-Flex Airflow System since Excellence & Innovation ~ 1957
More informationInstallation and Maintenance Instructions
Commercial & Industrial Positive Pressure or Condensing AL 29-4C Stainless Steel High Challenge Special Gas Vent Also for Natural Draft Appliances 3",4",5",6",7",8",9",10" and 12" Diameter Special Gas
More informationCHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS
CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS 6.1 Types of Heating Systems 6.2 Heating Energy Sources 6.3 Furnaces and Air Heaters 6.4 Boilers 6.5 District Heating 6.6 Selection of Medium- Steam
More informationTechnical and Dimensional Data. Saf-T Vent SC Plus
Technical and Dimensional Data Saf-T Vent S Plus 3"/5" & 4"/7" oncentric Reduced learance Double Wall for Special Gas Vent and/or Sealed ombustion Systems lso For Venting Listed Gas or Oil Fired ppliances
More informationP P Gas Fireplace. P See Thru
P121-10 - P131-10 Gas Fireplace Model P121/P131-NG10 P121/P131-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa)
More information2012 International Mechanical Code Significant Changes. About the Significant Changes
Significant Changes to the International Mechanical Code and the International Fuel Gas Code With Louisiana Amendments Copyright Materials This presentation is protected by US and International Copyright
More informationEsse B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL
Esse 700 27B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL Esse Stoves & Cookers Long Ing. Barnoldswick, Lancashire BB18 6BN. United Kingdom. Tel: + 44 (0) 1282 813235 F: + 44 (0) 1282 816876 enquiries@esse.com
More informationInstallation Requirements for Models:
900 & 9100 Series Refrigerators Installation Requirements for Models: 9162 9163 9182 9183 962 963 982 983 WARNING Improper installation, adjustment, alteration, service, or maintenance can cause injury
More informationDIVISION FINNED WATER-TUBE WATER HEATERS
DELTA LIMITED, TYPE WH - MODELS 399B-899B SUGGESTED SPECIFICATIONS Catalog No.: 3500.97B Effective: 04-01-17 Replaces: 11-15-08 DIVISION 23 52 33.13 FINNED WATER-TUBE WATER HEATERS - GENERAL 1.1 SUMMARY
More informationRSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...
Installation & Operating Manual RSIF Power Venter USA CAN Product Information... Chapters 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration... Chapter
More informationNovaVent. Dimensional Data
NovaVent Dimensional Data NovaVent The new vent system designed and engineered for today s competitive sales environment. NovaVent NovaVent is designed and engineered to meet the requirements of gas-fired
More informationCombustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.
System Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641. DVL Double-wall interior close clearance stovepipe for connecting woodstoves to chimney. ULC
More informationRS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN
Installation & Operating Manual 3000270 10.01 USA CAN RS Chimney Fan For Gas & Oil Applications 1200 Northmeadow Parkway, STE 180 Roswell, GA 30076 (770) 587-3238 (800) 255-2923 Fax (770) 587-4731 info@exhausto.com
More informationEXHAUST SYSTEMS COMMERCIAL CHIMNEY LINING SYSTEMS.
www.jeremiasinc.com GENERAL INFORMATION COMMERCIAL CHIMNEY LINING If an existing chimney is showing signs of wear and tear due to its age or no longer fulfills the requirements of a modern heating system,
More informationINSTALLATION INSTRUCTIONS
ELIMINATOR 36 Wood Burning Fireplace Models: 36E Non-Circulating (Smooth Face) I36E Non-Circulating (Smooth Face) Fully Insulated INSTALLATION INSTRUCTIONS SAVE THIS BOOK This book is valuable. In addition
More informationBDM Direct Vent systems are for use with direct vent gas fired appliances.
INSTALLATION INSTRUCTIONS Pro-Form DIRECT VENT SYSTEM Tested to ANSI Z21.88-2009 /CSA 2.33-2009 REPORT # 369-P-02b-6.5 Read through all venting and appliance instructions before beginning your installation.
More informationINSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods
INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods Ultra Series Models: UL2824 UL2830 UL2836 CONTENTS: Part 1 - Planning The Installation Part 2 - Electrical Connection Part 3
More informationInstallation, Operation and Service Manual
Installation, Operation and Service Manual Direct Vent CO-AXIAL DIRECT VENT SYSTEM DVS-100 INSTALLATIONS MUST MEET ALL LOCAL AND FEDERAL CODES THAT MAY DIFFER FROM THIS MANUAL Please read the manual in
More informationVenting Supplement Saf-T Vent 3" venting Special gas vent system vent and combustion air supplement for 3" diameter venting Hazard definitions
GOLD GV Water Boiler Series 3 & 4 Venting Supplement 3" venting Special gas vent system vent and combustion air supplement for 3" diameter venting Heat-Fab, Inc. AL29-4C Stainless Steel Special Gas Vent
More informationOWNERS MANUAL MODEL DO110 & DO180 IS CERTIFIED TO: Unit Serial # Purchased From Company Address
OWNERS MANUAL MODEL DO110 & DO180 IS CERTIFIED TO: UL 391 CAN/CSA B366.1 Unit Serial # Purchased From Company Address Name of Installer Installer Telephone # Date Installed IMPORTANT This manual must be
More informationVenting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4
GOLD GV Water Boiler Series 3 & 4 Venting Supplement Direct Vent Through-Roof or Through-Unused-Chimney For use with Weil-McLain Through-Roof or Through- Unused-Chimney Termination Kit Kit part # 382-200-435
More informationIntegrated Ventilation System
Integrated Ventilation System For use with models: IVS1, IVSR1, IVS2, IVSR2 Installation Instructions Part No. 65278 Rev. K Table of Contents Important Safety Instructions... 1 Important Information About
More informationPLATE HEAT EXCHANGERS BETTER BY DESIGN
PLATE HEAT EXCHANGERS BETTER BY DESIGN Construction that s better by design. Polaris quality demands careful attention to the materials and craftsmanship in every heat exchanger we make. Here s why you
More information