APPROVAL SHEET S PE CIFICATIONS OF HE R ME TIC S CR OLL COMPR E S S OR CODE MODE L C-S B353H8A

Size: px
Start display at page:

Download "APPROVAL SHEET S PE CIFICATIONS OF HE R ME TIC S CR OLL COMPR E S S OR CODE MODE L C-S B353H8A"

Transcription

1 Dirección: Scalabrini Ortiz 1375, Bs. As. Teléfonos: /6006/ No. : J S GGS Y-06 APPROVAL SHEET S PE CIFICATIONS OF HE R ME TIC S CR OLL COMPR E S S OR CODE MODE L C-S B353H8A NO. DATE PAGE REVISION DETAILS S ANYO S IGNE D CLIE NT S IGNE D REVISION RECORD USER : MANUFAC TUR E R : DALIAN SANYO COMPRESSOR CO., LTD. LEADER PURCHASING MANAGE R TECHNICAL MANAGE R APPROVED CHECKED SUBMITTED 1

2 Section 1. General Specifications 2

3 Section 2. Perform ance W arranty 2.1 Perform ance Standard Rating Conditions 2.2 Sound Level 2.3 Minim um Starting Voltage Conditions 2.4 Others 3

4 Section 3. Standard Accessories 3.1 Accessories List Parts Name Qty Parts code Revision No. Note TerminalBox Cover 1 A-0101-DSB 0 Insta led on Compressor TerminalBox Clip 1 A-0201-DSB 0 Insta led on Compressor Insulating Grommet 1 A-0301-DSB 0 Insta led on Compressor Mounting Grommet 4 M-0101-DSB 0 Included with Compressor Mounting Sleeve 4 M-0201-DSB 0 Included with Compressor Screw Special 1 B-0101-DSB 0 Insta led on Compressor 3.2 The Drawing for Reference Parts Name Compressor Outline Drawing Mounting Parts Listing Packing Dimensions Nameplate W iring Diagram Parts Code D-0101-DSB M-5101-DSB D-0201-DSB A-5106-DSB E-0910-DSB Revision No Inernal Moter Protector (in compressor) Parts Name Specification InernalMotor Protector Trip Temprature Reset Temprature Trip Current 145±5 61±9 47A /2~10s 4

5 Section 4. Compressor Protection 4.1 Protection Required but not Included with compressor Position of the Protection and Refrigerant Charging 5

6 Section 5. Operating Envelope Suction Gas Superheat 11.1K Refrigerant R22 Condensing Temperature Evaporating Temperature 6

7

8 Notes 1 Installation should be completed within 15 minutes after removing the rubber plugs. 2 Do not use the compressor to compress air. 3 Do not energize the compressor under vacuumed conditon. 4 Liquid refrigerant should be charged on liquid line between condenser and receiver. Do not charge the liquid refrigerant on the suction or discharge pipe of the compressor. 5 Do not tilt over the compressor while carrying it. 6 Do not remove the paint. 7 Crankcase heater is required when the oil sump temperature is too low to meet the requirement of item 6 on page7. 8 Voltage fluctuation between compressor terminals,during operation,shall be within 2% of the rated voltage. 9 Do not operate compressor in reverse rotational direction. 10 Suction strainers are recommended for all applications. 8

9

10 No. Part Code Qty Name Compressor 2 A-0101-DSB 1 Terminal Box Cover 3 A-0201-DSB 1 Terminal Box Clip 4 A-0301-DSB 1 Insulating Grommet 5 A-5102-DSB 1 Nameplate 6 B-0101-DSB 1 Screw Special 10 U V W Part Code D-0101-DSB Name Compressor Outline Drawing

11

12 ` 1125 [44.291] [45.197] 1160 [45.669] 1086 [42.756] [ ] 410 [2.362] 60 [2.362] 90[3.543] 60 [2.362] 410 [2.362] 60 [2.362] [ ] Part Code D-0201-DSB Name Packing Dimensions

13 C-SB353H 8A 3W 13 Part Code A-5106-DSB Name Nameplate

14 SWITCH V POWER SUPPLY 50Hz 380~415V R S T U INTERNAL PROTECTOR W MAGNETIC SWITCH COMPRESSOR R C 14 POWER SUPPLY 50Hz 220V S T REVERSAL DEFENSIBLE RELAY B A CRANKCASE HEATER Part Code E-0910-DSB Name W iring Diagram

Código : Motc.PANASONIC-CSC903H8K-12HP-PARALELO- Section 1. General Specifications

Código : Motc.PANASONIC-CSC903H8K-12HP-PARALELO- Section 1. General Specifications Código : 984031 Motc.PANASONIC-CSC903H8K-12HP-PARALELO- Section 1. General Specifications Section 2. Perform ance W arranty 2.1 Perform ance Standard Rating Conditions 2.2 Sound Level 2.3 Minim um Starting

More information

APPROVAL SHEET SPECIFICATIONS OF HERMETIC SCROLL COMPRESSOR C-SBR180H16A

APPROVAL SHEET SPECIFICATIONS OF HERMETIC SCROLL COMPRESSOR C-SBR180H16A No. :WXXS-000-GGSY-12 APPROVAL SHEET SPECIFICATIONS OF HERMETIC SCROLL COMPRESSOR MODEL C-SBR180H16A NO. DATE PAGE REVISION DETAILS SANYO SIGNED CLIENT SIGNED REVISION RECORD USER: MANUFACTURER: DALIAN

More information

Código : Motc.PANASC/SANYO-CSB453H8A--6HP-15100fr

Código : Motc.PANASC/SANYO-CSB453H8A--6HP-15100fr Código : 98422 Motc.PANASC/SANYO-CSB453H8A--6HP-151fr Section 1. General Specifications Content Unit Specification Compressor Model (Code) C-SB453H8A (89 86 88) Type Application Evap. Temp. Range Compressor

More information

NM1850 SERVICE PARTS

NM1850 SERVICE PARTS This parts list contains the service parts and wiring diagrams for this model. Check the model number in question to be sure that it is applicable to this parts list. NM0 SERVICE PARTS TABLE OF CONTENTS

More information

NM952 SERVICE PARTS TABLE OF CONTENTS. Cabinet Air Cooled Refrigeration Water Cooled Refrigeration Water System Gearmotor...

NM952 SERVICE PARTS TABLE OF CONTENTS. Cabinet Air Cooled Refrigeration Water Cooled Refrigeration Water System Gearmotor... This parts list contains the service parts and wiring diagrams for this model. Check the model number in question to be sure that it is applicable to this parts list. NM9 SERVICE PARTS TABLE OF CONTENTS

More information

SECTION 7 AIR CONDITIONING (COOLING) UNIT 41 TROUBLESHOOTING

SECTION 7 AIR CONDITIONING (COOLING) UNIT 41 TROUBLESHOOTING SECTION 7 AIR CONDITIONING (COOLING) UNIT 41 TROUBLESHOOTING UNIT OBJECTIVES After studying this unit, the reader should be able to Select the correct instruments for checking an air conditioning unit

More information

Danfoss scroll for refrigeration LLZ013 to low temperature

Danfoss scroll for refrigeration LLZ013 to low temperature MAKING MODERN LIVING POSSIBLE Application guidelines Danfoss scroll for refrigeration LLZ013 to 033 - low temperature 50-60 Hz - R404A - R507 http://cc.danfoss.com Contents Features...4 Scroll compression

More information

Contour TM Screw Compressors

Contour TM Screw Compressors Contour TM Screw Compressors Semi-Hermetic Compact Operating Instruction SCH1 High Temp Compressors Form No. 99-77 1. Introduction This series of semi-hermetic compact screw compressors is designed for

More information

NE6210CZ NE6210CZ C O M P R E S S O R TECHNICAL SPECIFICATION HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD

NE6210CZ NE6210CZ C O M P R E S S O R TECHNICAL SPECIFICATION HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD NE6210CZ NE6210CZ C O M P R E S S O R TECHNICAL SPECIFICATION HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD. 2007.3 INDEX page 1 Compressor Type..2 2 Performance Data.2 3 Running Condition 2 4 Compressor

More information

For more Parts Information:

For more Parts Information: For more Parts Information: https://manitowocfsg.sysonline.com/default.aspx TABLE OF CONTENTS Manitowoc Foodservice [Updated: Sep. 30, 2013] Manitowoc - Ice & Related Parts Catalog Ice Machine Q Series

More information

Trouble Shooting Guide FAA, 3-phase (D3631)

Trouble Shooting Guide FAA, 3-phase (D3631) Trouble Shooting Guide FAA, 3-phase (D3631) Trouble Shooting Guide Problem Possible Cause Possible Remedy Unit does not start Unit does not cool No power to unit, breaker tripped Low voltage tripped Loose

More information

AFE400 SERVICE PARTS

AFE400 SERVICE PARTS This is the parts list for the AFE00. When looking up part numbers, always check the complete model and serial numbers to be certain of ordering the correct parts. The Air Cooled model has also been manufactured

More information

CMS1402 SERVICE PARTS

CMS1402 SERVICE PARTS This parts lists shows the service parts for the CMS1402 air cooled and the CMS1402 water cooled. A B model was introduced in early 1992, the major change was the front panels. Check the model number of

More information

For more Parts Information: https://manitowocfsg.sysonline.com/default.aspx

For more Parts Information: https://manitowocfsg.sysonline.com/default.aspx For more Parts Information: https://manitowocfsg.sysonline.com/default.aspx TABLE OF CONTENTS Manitowoc Foodservice [Updated: Sep. 30, 2013] Manitowoc - Ice & Related Parts Catalog Ice Machine Q Series

More information

CME1856W Service Parts

CME1856W Service Parts This parts list contains the part numbers and description of the replacement parts available for this model. To avoid costly and time consuming errors, double check the model and voltage before ordering

More information

Danfoss Scroll for Refrigeration MLM / MLZ

Danfoss Scroll for Refrigeration MLM / MLZ s Danfoss Scroll for Refrigeration MLM / MLZ 50-60 Hz - R404A - R507 - R134a - R22 - R407A - R407F http://danfoss.us.com/ Contents Features... 6 Scroll compression principle... 7 The scroll compression

More information

AE R1 October to 5 Ton ZPS*K6 Copeland Scroll Two-Stage Compressors

AE R1 October to 5 Ton ZPS*K6 Copeland Scroll Two-Stage Compressors October 2017 1.5 to 5 Ton ZPS*K6 Copeland Scroll Two-Stage Compressors Safety Safety Instructions... 2 Safety Icon Explanation... 2 Instructions Pertaining to Risk of Electrical Shock, Fire, or Injury

More information

CK C O M P R E S S O R

CK C O M P R E S S O R CJ62 6232 32CK CK C O M P R E S S O R TECHNICAL SPECIFICATION ; HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD. 2011.8 INDEX page 1 Compressor Type..2 2 Performance Data.2 3 Running Condition 2 4 Compressor

More information

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

A/C-HEATER SYSTEM - MANUAL

A/C-HEATER SYSTEM - MANUAL A/C-HEATER SYSTEM - MANUAL 1986 Isuzu Trooper II 1986 A/C-HEATER SYSTEM Isuzu A/C-Heater Systems - Manual P UP, Trooper II * PLEASE READ THIS FIRST * CAUTION: When discharging air conditioning system,

More information

CME1856W Service Parts

CME1856W Service Parts This parts list contains the part numbers and description of the replacement parts available for this model. To avoid costly and time consuming errors, double check the model and voltage before ordering

More information

.2 Section Waste Management and Disposal.

.2 Section Waste Management and Disposal. Issued 2005/06/01 Section 15624 Packaged Rotary Screw Water Chillers Page 1 of 5 PART 1 General 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

CJ6240CK COMPRESSOR TECHNICAL SPECIFICATION HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD

CJ6240CK COMPRESSOR TECHNICAL SPECIFICATION HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD CJ6240CK COMPRESSOR TECHNICAL SPECIFICATION HUANGSHI DONPER ELECTRICAL APPLIANCE CO., LTD. 2005.10 INDEX page 1 Compressor Type..2 2 Performance Data.2 3 Running Condition 2 4 Compressor Mechanical Information

More information

Refrigeration System with a Capillary Tube and a Thermostat

Refrigeration System with a Capillary Tube and a Thermostat Exercise 2-1 Refrigeration System with a Capillary Tube Part A: REFRIGERATION CIRCUIT OBJECTIVE When you have completed this part, a refrigeration circuit using a capillary tube as a metering device will

More information

AIR-CONDITIONER SERVICE MANUAL

AIR-CONDITIONER SERVICE MANUAL FILE NO. A90-9608 SERVICE MANUAL AIR-CONDITIONER S SPLIT BUILT-IN DUCT TYPE RAV-362B-PE/ RAV-462B-PE/ SPLIT CEILING TYPE RAV-362C-PE/ RAV-462C-PE/ SPLIT CASSETTE TYPE RAV-362U-PE/ RAV-462U-PE/ PRINTED

More information

Inverter scroll compressors VSH

Inverter scroll compressors VSH Application guidelines Inverter scroll compressors VSH088-117-170 50-60 Hz - R410A http://cc.danfoss.com Content VSH scroll specificities... 6 Inverter compressors... 7 Compressor size... 7 Frequency

More information

MAKING MODERN LIVING POSSIBLE. MLZ / MLM Refrigeration scroll compressors Hz - R404A - R507 - R134a - R22. Selection & application guidelines

MAKING MODERN LIVING POSSIBLE. MLZ / MLM Refrigeration scroll compressors Hz - R404A - R507 - R134a - R22. Selection & application guidelines MAKING MODERN LIVING POSSIBLE MLZ / MLM Refrigeration scroll compressors 50-60 Hz - R404A - R507 - R134a - R22 Selection & application guidelines Contents Features... 4 Scroll compression principle...

More information

Performer Heat Pump scroll compressors 50 Hz - R407C Selection & application guidelines

Performer Heat Pump scroll compressors 50 Hz - R407C Selection & application guidelines MAKING MODERN LIVING POSSIBLE Performer Heat Pump scroll compressors 50 Hz - R407C Selection & application guidelines CONTENTS SCROLL COMPRESSION PRINCIPLE... 3 Scroll compressor components... 3 The

More information

Condensing Unit Installation and Operating Instructions

Condensing Unit Installation and Operating Instructions Bulletin WCU_O&I 01 June 2003 Condensing Unit Installation and Operating Instructions WCU Air Cooled Condensing Unit Table of Contents Section 1. Section 2. Section 3. Section 4. Section 5. Section 6.

More information

CU0415, CU0715 and CU0920 Service Parts

CU0415, CU0715 and CU0920 Service Parts CU0, CU0 and CU00 Service Parts This is the illustrated parts list for the CU0, CU0 and CU00. The CUR0, CUR0 and CUR00 are - (0-0/0/) versions of the matching models. There are voltages, /0/, 0-0/0/ and

More information

Maneurop reciprocating compressors

Maneurop reciprocating compressors MAKING MODERN LIVING POSSIBLE Maneurop reciprocating compressors NTZ R404A - R507A SELECTION & APPLICATION GUIDELINES CONTENTS MANEUROP RECIPROCATING COMPRESSORS... 4 Features... 4 Compressor reference...

More information

DANFOSS OPTYMA PLUS INVERTER UNITS

DANFOSS OPTYMA PLUS INVERTER UNITS Optyma Plus Inverter Condensing Units Danfoss Optyma Plus Inverter Units are designed with the unique benefits of stepless inverter scroll technology resulting in a 20-30% higher energy efficiency in a

More information

AE Application Guidelines for Refrigeration Copeland Discus Compressors with R-410A

AE Application Guidelines for Refrigeration Copeland Discus Compressors with R-410A AE4-1392 July 2014 Application Guidelines for Refrigeration Copeland Discus Compressors with R-410A Section TABLE OF CONTENTS Page Safety Safety Instructions...2 Safety Icon Explanation...2 Instructions

More information

Inverter scroll compressors VSH

Inverter scroll compressors VSH Inverter scroll compressors VSH088-117-170 50-60 Hz - R410A http://danfoss.us.com/ Content VSH scroll specificities...6 Inverter compressors...7 Compressor size...7 Frequency converter variants...7 Compressor

More information

Application Engineering

Application Engineering APPLICATION GUIDELINES FOR ZB*KC/ZB*KCE COPELAND SCROLL REFRIGERATION COMPRESSORS 7 TO 15 HP AE4-1318 R1 June 2008 Introduction The Copeland Scroll ZB*KC/ZB*KCE refrigeration compressor product offering

More information

1. TF Hermetic Reciprocating Compressor

1. TF Hermetic Reciprocating Compressor 1. TF Hermetic Reciprocating Compressor The TF range of refrigeration compressors have cooling capacity from 37 to 1050W and coefficient of performance (COP) from 1.23 to 1.95 W/W. Our products have been

More information

Spare Parts Catalogue AC176

Spare Parts Catalogue AC176 Spare Parts Catalogue AC176 1 - UNIT PANELS 2 - REFRIGERANT SYSTEM AIR COOLED 3 - REFRIGERANT SYSTEM WATER COOLED 4 - WATER SYSTEM - SMALL CUBE 5 - WATER SYSTEM - MEDIUM CUBE 6 - WATER SYSTEM - LARGE CUBE

More information

UNIT PANELS 6/25/ :15:30 AM Page 2 of 27

UNIT PANELS 6/25/ :15:30 AM Page 2 of 27 MF56 1 UNIT PANELS 2 REFRIGERANT SYSTEM AIR COOLED 3 REFRIGERANT SYSTEM WATER COOLED 4 WATER SYSTEM AND INSULATIONS - UP TO S.N. 23384 5 WATER SYSTEM AND INSULATIONS - FROM S.N. 23385 TO S.N. 24159 6 WATER

More information

M P 1 2 F G C O M P R E S S O R TECHNICAL SPECIFICATIO N

M P 1 2 F G C O M P R E S S O R TECHNICAL SPECIFICATIO N M P 1 2 F G C O M P R E S S O R TECHNICAL SPECIFICATIO N (200-220~50Hz & 220-230V~60Hz) REFRITZ LTD 2016.08 1.Compressor Type Compressor model Approximate Power Rated voltage/frequency Refrigerant Application

More information

HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B COUNTER SHOWCASE MODEL SERVICE MANUAL HOSHIZAKI

HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B COUNTER SHOWCASE MODEL SERVICE MANUAL HOSHIZAKI NO. S051-800 ISSUED: MAR. 26, 2010 REVISED: HOSHIZAKI COUNTER SHOWCASE MODEL HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B SERVICE MANUAL IMPORTANT This manual should be read carefully

More information

Application Guidelines for ZS**KAE Refrigeration Copeland Scroll Compressors HP

Application Guidelines for ZS**KAE Refrigeration Copeland Scroll Compressors HP AE4-1387 R8 April 2015 Application Guidelines for ZS**KAE Refrigeration Copeland Scroll Compressors 1.3-4.5 HP TABLE OF CONTENTS Section Page Section Page Safety Safety Instructions...2 Safety Icon Explanation...2

More information

Inverter scroll compressors VZH hybrid manifold

Inverter scroll compressors VZH hybrid manifold Application guidelines Inverter scroll compressors VZH hybrid manifold R410A http://cc.danfoss.com Contents...4 Scope...4 Benefits...4...5 Oil management concept...5 System configuration...5 Dimensions...8

More information

Refrigerated Compressed Air Dryer

Refrigerated Compressed Air Dryer Manual Instruction for Refrigerated Compressed Air Dryer Warning: Place the dryer machine horizontal. Never upside down Dino-power Industry & Trade Co., Ltd www.aircompressorschina.com Dino-power 1 PREPARED

More information

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit RCW-54CB RO-50CA RC-54CA RO-50CA RC-54HA RO-50HA CONTENTS SPECIFICATIONS OUTLINE AND DIMENTIONS CIRCUIT DIAGRAM REFRIGERANT SYSTEM

More information

Application Guidelines for Glacier K3 Copeland Scroll Refrigeration Compressors

Application Guidelines for Glacier K3 Copeland Scroll Refrigeration Compressors AE4-1296 R3 March 2013 Application Guidelines for Glacier K3 Copeland Scroll Refrigeration Compressors TABLE OF CONTENTS Section Page Section Page Safety Instructions... 2 Safety Icon Explanation... 2

More information

Trouble Shooting Guide PWA, 3-phase (D10571)

Trouble Shooting Guide PWA, 3-phase (D10571) Trouble Shooting Guide PWA, 3-phase (D10571) Trouble Shooting Guide Problem Possible Cause Possible Remedy Unit does not start Unit does not cool No power to unit, breaker tripped Low voltage Loose wire

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

SCE170 SERVICE PARTS

SCE170 SERVICE PARTS This is the parts list for the SCE170. When looking up part numbers, always check the complete model and serial numbers to be certain of ordering the correct parts. The SCE170 has been manufactured in

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

Scroll Compressors for Heat Pump Applications ZH12K4E to ZH11M4E, ZH06KVE to ZH48KVE

Scroll Compressors for Heat Pump Applications ZH12K4E to ZH11M4E, ZH06KVE to ZH48KVE Scroll Compressors for Heat Pump Applications ZH12K4E to ZH11M4E, ZH06KVE to ZH48KVE About this guideline... 1 1 Safety instructions... 1 1.1 Icon explanation... 1 1.2 Safety statements... 1 1.3 General

More information

UNIT PANELS 6/25/2014 9:02:04 AM Page 2 of 23

UNIT PANELS 6/25/2014 9:02:04 AM Page 2 of 23 AC126 1 UNIT PANELS 2 REFRIGERANT SYSTEM AIR COOLED 3 REFRIGERANT SYSTEM WATER COOLED 4 WATER SYSTEM - SMALL CUBE 5 WATER SYSTEM - MEDIUM CUBE 6 WATER SYSTEM - LARGE CUBE 7 CONTROL BOX AND P.C. BOARD -

More information

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2) CS*/CD*/CP* Series Air Cooled Condensing Units Operating and Installation Manual CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2) TABLE OF CONTENTS I. Receipt of Equipment 2 II. Piping...4 III. System

More information

Danfoss scroll compressors SM - SY - SZ

Danfoss scroll compressors SM - SY - SZ MAKING MODERN LIVING POSSIBLE Application guidelines Danfoss scroll compressors SM - SY - SZ R22 - R407C - R137a - R404A - R507A - 50-60 Hz www.danfoss.us.com Content Danfoss scroll compression principle...4

More information

Danfoss scroll compressors In parallel installation SM/SY/SZ

Danfoss scroll compressors In parallel installation SM/SY/SZ Application guidelines Danfoss scroll compressors In parallel installation SM/SY/SZ http://cc.danfoss.com Content Compressor model designation... 4 Nomenclature...4 General overview... 5 Benefits...5

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

RP8.1Y (ERRATA 1) (202) 2 of 8

RP8.1Y (ERRATA 1) (202) 2 of 8 530.18-RP8.1Y (ERRATA 1) (202) 2 of 8 ELECTRICAL (Cont.) FIG ITEM DESCRIPTION D6CG048N06006A D6CG048N06025A D6CG048N06046A D6CG048N06058A 3-BURNER 3-BURNER 3-BURNER 3-BURNER * 15 CONNECTOR, CAP (9-CIRCUIT)

More information

APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models)

APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models) 4-1280 Application Engineering Bulletin AE-1280R4 Revised April, 1995 APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models) Introduction The Compliant Scroll Compressor has been

More information

McQuay. Screw Chiller Water Cooled. WHS Vintage A. Last Manufactured: Replacement Parts List No New 07/2012

McQuay. Screw Chiller Water Cooled. WHS Vintage A. Last Manufactured: Replacement Parts List No New 07/2012 Replacement s List No. 700024500 New 07/2012 McQuay Screw Chiller Water Cooled WHS 155-200 Vintage A Last Manufactured: 2000 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

2 shp 13 lc 1 36 t - 1 a

2 shp 13 lc 1 36 t - 1 a HEAT PUMPs 2SHP3 PRODUCT SPECIFICATIONS Dry Charge Split System - 60 HZ Bulletin No. 20645 July 203 Supersedes June 202 3 to 5 Tons MODEL NUMBER IDENTIFICATION 2 shp 3 lc 36 t - a Refrigerant Type 2 =

More information

McQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1)

McQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1) Replacement Parts List No. 110510700 Revision G 02/2015 McQuay Concealed Ceiling Water Source Heat Pump WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1) WCAS, WCDA, WCDL, WCDS, WCMS 030 Design

More information

Trouble Shooting Guide RAA, 1-phase (D3627)

Trouble Shooting Guide RAA, 1-phase (D3627) Trouble Shooting Guide RAA, 1-phase (D3627) Trouble Shooting Guide Problem Possible Cause Possible Remedy Unit does not start Unit does not cool No power to unit, breaker tripped Low voltage tripped Loose

More information

September 2016 AE Application Guidelines for Copeland CS**KIE Compressors in Ice Machines AE4-1421

September 2016 AE Application Guidelines for Copeland CS**KIE Compressors in Ice Machines AE4-1421 AE4-1421 September 2016 Application Guidelines for Copeland CS**KIE Compressors in Ice Machines TABLE OF CONTENTS Section Page Section Page Safety Safety Instructions... 2 Safety Icon Explanation... 2

More information

Danfoss scroll compressors SM SY SZ

Danfoss scroll compressors SM SY SZ Application guidelines Danfoss scroll compressors SM SY SZ R22 - R407C - R134a - R404A - R507A - 50-60 Hz http://cc.danfoss.com Content Compressor model designation... 4 Nomenclature...4 Danfoss scroll

More information

Trouble Shooting Guide PAA, 1-phase (D3731)

Trouble Shooting Guide PAA, 1-phase (D3731) Trouble Shooting Guide PAA, 1-phase (D3731) Trouble Shooting Guide Problem Possible Cause Possible Remedy Unit does not start Unit does not cool No power to unit, breaker tripped Low voltage tripped Loose

More information

38LB/38LF AIR COOLED CONDENSING UNIT

38LB/38LF AIR COOLED CONDENSING UNIT WORLD LEADER IN AIR CONDITIONING AND HEATING TECHNOLOGY INSTALLATION, START-UP AND SERVICE INSTRUCTIONS 38LB/38LF AIR COOLED CONDENSING UNIT CONTENTS PAGE PHYSICAL DATA 2 PHYSICAL DATA 2 DIMENSION DATA

More information

Performer scroll compressors. SM - SY - SZ Hz R22 - R407C - R134a - R404A - R507A. Selection & application guidelines

Performer scroll compressors. SM - SY - SZ Hz R22 - R407C - R134a - R404A - R507A. Selection & application guidelines MAKING MODERN LIVING POSSIBLE Performer scroll compressors SM - SY - SZ - 50-60 Hz R22 - R407C - R134a - R404A - R507A Selection & application guidelines CONTENT PERFORMER SCROLL COMPRESSION PRINCIPLE...5

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513 TECHNICAL & SERVICE MANUAL SA 123A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-123A 1 851 006 95 Australia SA 123A REFERENCE NO. SM700513 IMPORTANT! Please Read Before

More information

Danfoss scroll compressors SH090 to SH485 - single

Danfoss scroll compressors SH090 to SH485 - single Application guidelines Danfoss scroll compressors SH090 to SH485 - single 50 Hz - 60 Hz - R410A http://cc.danfoss.com Content Scroll compression principle... 4 Features... 5 Compressor model designation...

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A TECHNICAL & SERVICE MANUAL SA 183A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. SA-183A 1 851 006 96 Destination Australia SA 183A REFERENCE NO. SM700514 IMPORTANT! Please Read Before

More information

INSTRUCTIONS P01-A Danfoss Commercial Compressors March 2006

INSTRUCTIONS P01-A Danfoss Commercial Compressors March 2006 INSTRUCTIONS 0.5% slope 4 m/s or more max. 4 m A B U-trap max. 4 m 8 to 12 m/s 0.5% slope 4m/s or more Evaporator Fig. 1 Fig. 3 Fig 5 Fig. 2 IN OUT 4 Cyl. Fig. 4 1 & 2 Cyl. Suction riser dimension Suction

More information

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections. SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15410 - Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections. 1.02 SUBMITTALS A. Submit properly identified

More information

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS SECTION 22 20 00 LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements",

More information

Owners Manual UA75 TO UA1200 SERIES Refrigerated Air Dryer

Owners Manual UA75 TO UA1200 SERIES Refrigerated Air Dryer 1 Owners Manual UA75 TO UA1200 SERIES Refrigerated Air Dryer DESCRIPTION PAGE INTRODUCTION 2 INSTALLATION 3 INSTALLATION GUIDE 4 DRYER CONTROLS 5 DRYER CONTROLS AND SAFTEY SHUTDOWNS 6 START UP 6 INITIAL

More information

Danfoss scroll compressors SH090 to SH485 - single

Danfoss scroll compressors SH090 to SH485 - single Application guidelines Danfoss scroll compressors SH090 to SH485 - single 50 Hz - 60 Hz - R410A http://cc.danfoss.com Content Scroll compression principle... 4 Features... 5 Compressor model designation...

More information

NO. 15FD-742 ISSUED: AUG. 10, 2007 REVISED: SEP. 30, 2013 HOSHIZAKI SELF-CONTAINED CRESCENT CUBER KM-30A KM-35A KM-50A KM-75A MODEL SERVICE MANUAL

NO. 15FD-742 ISSUED: AUG. 10, 2007 REVISED: SEP. 30, 2013 HOSHIZAKI SELF-CONTAINED CRESCENT CUBER KM-30A KM-35A KM-50A KM-75A MODEL SERVICE MANUAL NO. 15FD-742 ISSUED: AUG. 10, 2007 REVISED: SEP. 30, 2013 HOSHIZAKI SELF-CONTAINED CRESCENT CUBER MODEL KM-30A KM-35A KM-50A KM-75A SERVICE MANUAL CONTENTS PAGE I. SPECIFICATIONS--------------------------------------------------------------------------------------1

More information

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A LS Condensate Removal Pump INSTRUCTION MANUAL 6-71-075-115 REVISION A CAUTION: Combustible liquids may not be pumped! The condensate pump may not be run dry, as this can destroy the bearings in a very

More information

Case 8 Basic Performance of Screw Compressor

Case 8 Basic Performance of Screw Compressor Case 8 Basic Performance of Screw Compressor Copy Right By: Thomas T.S. Wan ) June 24, 2010 All Rights Reserved Case Background: The basic rating and performance given by a compressor manufacturer is usually

More information

KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M

KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M 2004 Lennox Industries Inc. Dallas, Texas KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04 Supersedes 503,249M Litho U.S.A. COMPRESSOR REPLACEMENT KIT INSTALLATION INSTRUCTIONS FOR COMPRESSOR

More information

ICEU 36 SPARE PARTS LIST REV. 07/2016

ICEU 36 SPARE PARTS LIST REV. 07/2016 ICEU 36 ~ SPARE PARTS LIST REV. 07/2016 ICEU 36 1 UNIT PANELS UP TO S.N. 02594 2 UNIT PANELS FROM S.N. 02595 3 REFRIGERANT SYSTEM AIR COOLED UP TO S.N. 02413 4 REFRIGERANT SYSTEM AIR COOLED - FROM S.N.

More information

MAKING MODERN LIVING POSSIBLE. Residential and light commercial scroll compressors Hz R-407C / R-22 / R-410A SELECTION & APPLICATION GUIDELINES

MAKING MODERN LIVING POSSIBLE. Residential and light commercial scroll compressors Hz R-407C / R-22 / R-410A SELECTION & APPLICATION GUIDELINES MAKING MODERN LIVING POSSIBLE Residential and light commercial scroll compressors 50-60 Hz R-407C / R-22 / R-410A SELECTION & APPLICATION GUIDELINES CONTENTS Scroll compression principle... 5 The scroll

More information

A Series Inertia Compressor Applications. Application Bulletin 115

A Series Inertia Compressor Applications. Application Bulletin 115 A Series Inertia Compressor Applications Application Bulletin 115 Application Bulletin Subject: A Series Inertia Compressor Applications Number: 115 Release EN: 006X04 Date: 1/6/92 Revision EN: Z27301

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

CABINET PARTS REFRIGERATOR. For Models: GT2SHMXMS01 (Stainless Steel) Litho In U.S.A. (ebk) 1. Part No

CABINET PARTS REFRIGERATOR. For Models: GT2SHMXMS01 (Stainless Steel) Litho In U.S.A. (ebk) 1. Part No CABINET PARTS REFRIGERATOR 12 03 Litho In U.S.A. (ebk) 1 Part No. CABINET PARTS 1 Literature Parts LIT2225762 Service & Wiring Sheet LIT2301830 Energy Label LIT2225411 Use & Care Guide LIT2225413 Customer

More information

R100 Oil-Less Refrigerant Recovery Unit

R100 Oil-Less Refrigerant Recovery Unit R100 Oil-Less Refrigerant Recovery Unit Operation Manual 1 INTRODUCTION Welcome to simple, efficient refrigerant recovery with your new YELLOW JACKET Refrigerant Recovery Unit, R100. This unit combines

More information

CABINET PARTS For Models: W8RXNGMWB02, W8RXNGMWS02, W8RXNGMWL02 (Black) (Stainless Steel) (Satina)

CABINET PARTS For Models: W8RXNGMWB02, W8RXNGMWS02, W8RXNGMWL02 (Black) (Stainless Steel) (Satina) CABINET PARTS REFRIGERATOR 1 12 Litho In U.S.A. (mlg)(bay) 1 Part No. Rev.A CABINET PARTS 1 Literature Parts W10402929 Service & Wiring Sheet 2316016 Use & Care Guide 628370 Modular Icemaker Service Sheet

More information

MVC V2.0. MVC EEV Controller

MVC V2.0. MVC EEV Controller MVC EEV Controller EEV has been applied in refrigeration industry for a long time, and it is well known that EEV can improve the performance of the refrigerator, however, the EEV should work with pressure

More information

Technical Information

Technical Information Date of last update: May-12 Ref: : Application Engineering Europe ENHANCED VAPOUR INJECTION (EVI) FOR ZH*KVE SCROLL COMPRESSORS 1 Introduction... 2 2 Principle of operation... 2 3 Capacity effect... 3

More information

Volts 115 Wiring Diagram Owner's Guide Energy Guide Service Data Sheet Installation Instructions

Volts 115 Wiring Diagram Owner's Guide Energy Guide Service Data Sheet Installation Instructions White-Westinghouse Product No. Series R134a System Color white Volts 115 Wiring Diagram 241582401 Owner's Guide 241997501 Market North America Energy Guide 241613796 Service Data Sheet 241588203 Installation

More information

TOP MOUNT REFRIGERATOR MODELS: WRT106TFDW01 (White) WRT106TFDB01 (Black) WRT106TFDT01 (Biscuit)

TOP MOUNT REFRIGERATOR MODELS: WRT106TFDW01 (White) WRT106TFDB01 (Black) WRT106TFDT01 (Biscuit) TOP MOUNT REFRIGERATOR MODELS: WRT106TFDW01 (White) WRT106TFDB01 (Black) WRT106TFDT01 (Biscuit) 05/21/2015 2015 Whirlpool Corporation Part W10806768 Rev. A CABINET PARTS 05/21/2015 2 Part W10806768 Rev.

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338 TECHNICAL & SERVICE MANUAL SA 128S5 FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-128S5-A 1 851 004 09 General (50Hz) & Europe SA 128S5 REFERENCE NO. SM700338 IMPORTANT!

More information

The rotary type compressor consists of an integrally formed rotor and shaft, five vanes, and a cylinder.

The rotary type compressor consists of an integrally formed rotor and shaft, five vanes, and a cylinder. W1860BE.book Page 12 Tuesday, January 28, 2003 11:01 PM 2. Cooling System A: COMPRESSOR The rotary type compressor consists of an integrally formed rotor and shaft, five vanes, and a cylinder. As the rotor

More information

SECTION WATER-SOURCE UNITARY HEAT PUMPS

SECTION WATER-SOURCE UNITARY HEAT PUMPS SECTION 23 81 46 WATER-SOURCE UNITARY HEAT PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification

More information

McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000

McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000 Replacement s List No. 5709900 Revision N 0/205 McQuay Incremental MQE 007, 009, 02, 05, 06 MQR 007, 009, 02, 05 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call -800-377-2787

More information

Inverter scroll compressors VZH hybrid manifold

Inverter scroll compressors VZH hybrid manifold Application guidelines Inverter scroll compressors VZH hybrid manifold R410A http://cc.danfoss.com Contents...4 Scope...4 Benefits...4...5 Oil management concept...5 System configuration...5 Dimensions...8

More information

Parts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com

Parts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com Parts List Modular Crescent Cuber Models KM-901MAJ KM-901MWJ KM-901MRJ/3 hoshizakiamerica.com Number: 71391 Issued: 10-23-2017 Revised: 6-8-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts...

More information

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons) ENGINEERING DATA HEAT PUMP OUTDOOR UNITS HP40 50HZ Capacity 6.2 to 16.3 (21 200 to 55 500 Btuh) Heating Capacity 6.4 to 16.1 (21 800 to 55 500 Btuh) Bulletin No. 490088 October 2004 Supersedes August 1999

More information

DUCT type. Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

DUCT type. Большая библиотека технической документации   каталоги, инструкции, сервисные мануалы, схемы. SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit RD-25CA RD-25HA RD-30CA RD-30HA RO-25CA RO-25HA RO-30CA RO-30HA C O N T E N T S SPECIFICATIONS.............................................

More information

CABINET PARTS For Models: GT2SHMXMS04 (Stainless Steel)

CABINET PARTS For Models: GT2SHMXMS04 (Stainless Steel) CABINET PARTS REFRIGERATOR 11 05 Litho In U.S.A. (djc) 1 Part No. CABINET PARTS 1 Literature Parts 2314274 Service & Wiring Sheet 2302187 Energy Label 2314472 Use & Care Guide 2225413 Customer Instruct

More information

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator. Bottom Mount Technical Information Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.! CAUTIN All safety information

More information

Product Data. Features/Benefits. 07DA, DB 07EA, EB, ED Condensing Units. 06D, 06E Compressors. 3 to 40 Nominal Tons

Product Data. Features/Benefits. 07DA, DB 07EA, EB, ED Condensing Units. 06D, 06E Compressors. 3 to 40 Nominal Tons Product Data 07DA, DB 07EA, EB, ED Condensing Units 3 to 40 Nominal Tons 06D, 06E Compressors An excellent choice for your built-up system Carrier 07 Series condensing units built for the engineer who

More information