Selecting the Right Air-Powered Pump for Your Landfill Pumping Application

Size: px
Start display at page:

Download "Selecting the Right Air-Powered Pump for Your Landfill Pumping Application"

Transcription

1 Selecting the Right Air-Powered Pump for Your Landfill Pumping Application David Kaminski QED Environmental Systems Inc. Ann Arbor, MI / San Leandro, CA Copyright QED Environmental Systems, Inc. 2014; all rights reserved. The information contained within this document may not be published, broadcast, rewritten or otherwise distributed without prior written authorization from QED. Today s webinar topics Air-powered pump components Principles of operation and design features Application information and project requirements Factors that affect pump performance Selecting the pump configuration and materials Air compressor sizing and air dryer systems Air & liquid tubing or hose selection and pump fittings Accessories to improve pump performance, reliability and serviceability Special Pumps for Challenging Applications 1

2 2 Air Supply to Pump Air Exhaust Air Filter/Pressure Regulator Liquid Discharge Discharge Check Valve Pump Body Air Valve Mechanism Float Assembly Discharge Tube/ Float Guide Inlet Check Valve Inlet Screen Actuator Rod Automatic Air-Powered Pump Components Air-powered automatic pump: How it works Discharge Cycle When float reaches the top of its travel, exhaust valve closes and air inlet valve opens Air pressure against liquid closes inlet check valve and pushes liquid up discharge tube As liquid level drops, float drops and pulls actuator rod down, closing the air inlet valve and opening exhaust valve to repeat Fill Cycle Fill Cycle Hydrostatic pressure opens inlet check valve As pump fills with liquid, air escapes through exhaust valve and internal float rises

3 3 Air-powered pump design features High-clearance check valves and passages maximize solids handling, liquid viscosity Low-speed moving parts minimize wear Built-in on/off level control - no need for level sensors or float switches Gentle pumping action = less foaming and solids precipitation than impeller pumps Bottom inlet allows for maximum liquid drawdown pump down to 15 (38 cm) No need for cooling can pump liquids up to 250 F (120 C) without failure Wide range of materials handles low ph, high chlorides, solvents, corrosives, etc. Air power safer than electricity in wet or potentially explosive environments (LFG) What s the application? Air-powered automatic pumps can be used in most landfill pumping applications Dewatering LFG wells or dual extraction gas and leachate wells (vertical risers) Pumping from condensate sumps and demister pots Pumping from leachate collection risers (vertical risers) For sloped riser applications, air-powered pumps with surface-mounted controls can be used low-flow wells to pump up to 3000 GPD (11,350 LPD or 11.3 m 3 /day)

4 4 What are the application requirements? Total depth of the well, sump or riser, measured from top of casing Liquid column height (from bottom) or depth to liquid (from TOC) Drawdown level desired (from TOC) or desired maximum liquid column height remaining after pumping (measured from bottom) Maximum drawdown achievable will be reduced if the well is under vacuum by the amount equivalent to the vacuum applied (in inches of water column) Lift requirements above grade - pumping to tanks, ponds, up slopes Type of discharge header gravity flow or force main Gravity flow header may require some additional pump discharge pressure to move liquids the desired distance from the well or riser to the discharge point Force main header connection will require additional pump discharge pressure to overcome header pressure and one-way check valve at header connection Flow rate desired or specified If not known, determine if the maximum flow rate that can be achieved with the selected air-powered pump will handle the desired liquid volume over time Factors that affect flow rate Total head combines pump depth, discharge line elevation above the well and frictional loss in the piping, fittings, and in-line check valves Flow rate decreases as head increases at a given air pressure; increasing air pressure generally increases flow rate Submergence is the liquid level above the top of the pump; controls the pump fill rate Flow rate increases as submergence increases Viscosity is a measure of a liquid s thickness or resistance to flow. Flow rate decreases as viscosity increases at a given submergence, lift and air supply pressure.

5 5 Instantaneous vs. average flow rate Flow curves for airpowered pumps are based on the average flow rate over a period of time, stated in gallons per minute (GPM) or liters per minute (LPM) at a stated depth Discharge header sizing for air-powered pump systems is based on average flow rate, since multiple pumps will discharge and fill at random, not simultaneously Level control in the well: the pump actuation point The point at which the liquid level inside the pump activates the air valve mechanism is called the actuation point The actuation point is the distance from the bottom of the pump to the top of the float travel (top of inlet on top-fill pumps) This varies based on pump length, float length and inlet position and is specified for each pump model The pump position in the well determines the maximum drawdown level in the well

6 6 How vacuum affects the pump actuation point A vacuum applied to the well will RAISE the actuation point above the design point when the pump exhaust is outside the well The increase in the actuation point is based on the amount of vacuum applied to the well, measured in inches (centimeters) of water column (WC) In the example, a vacuum of 20 (51 cm) WC raises the actuation point of the pump from 33 (84 cm) to 53 (135 cm) Options for wells under vacuum To maintain the design actuation point of the pump, the exhaust air line should be terminated inside the well. If exhaust air entering the well is an issue (e.g., O 2 & N 2 in a landfill gas system), the exhaust air line can be terminated outside the well. The pump can be lowered in the well to maintain desired liquid level, or a shorter pump with a lower actuation point can be used if the desired flow rate can be achieved. Where higher flow rates are needed and exhaust air must be outside the well, an equalization valve can be used to direct the majority of the exhaust air outside the well while applying vacuum to the exhaust line to lower the actuation point.

7 7 Selecting the pump configuration Bottom-inlet pump models are most commonly used for landfill applications to maximize drawdown and solids removal from the well, riser or sump Long-body pumps provide the highest flow rates but require the greatest submergence to operate Max14 GPM (53 LPM) flow, 38.4 (98 cm) drawdown Short-body pumps provide nearly the same maximum flow rate as long-body models but have a lower actuation point (more drawdown capability) and somewhat shorter service life Max13 GPM (49 LPM) flow, 26.7 (68 cm) drawdown Low-drawdown pumps have the lowest actuation point for maximum drawdown but provide lower flow rates, and can have a shorter service life when operating at higher cycling rates Max 7 GPM (26.5 LPM) flow, 15.3 (39 cm) drawdown Slider Pump for sloped risers The Slider pump is an air displacement pump with special check valves that work in sloped leachate risers and slant wells The Slider pump uses surface-mounted controls and a bubbler-type level control system to pump up to 3000 GPD (11,350 LPD or 11.3 m3/day) Automatic air-powered pumps are designed for use in vertical risers and wells the float mechanism and check valves won t work in sloped risers

8 8 Pump materials and corrosive conditions Corroded Stainless Steel Pipe Corrosion is often the result of elevated chloride levels (>1,000 ppm), especially at temperatures above 75 F (24 C) and low ph, which can be as low as 1.5 in landfill leachate and condensate QED s air-powered automatic pumps are available in a range of corrosion-resistant material configurations. The pump mechanism is not adversely affected by moderate corrosion. The AutoPump AP4+ Leachate model using stainless steel and PVDF parts is warranted for all typical landfill liquid chemistries at temperatures up to 180 F (82 C) Pump failure due to corrosion Corrosion can also be induced by high sulfides, reducing conditions (low to no oxygen present), and microbial attack from sulfate-reducing bacteria or iron bacteria Corrosion begins at the weakest point pumps made with welded bodies rather than seamless tubing and welded or machined components that haven t been properly treated after machining. WELD FAILURE

9 9 Air system design criteria 1. Determine the air pressure and air flow rate (volume) required for each pump and the total for all pumps 2. Allow for future system expansion if anticipated; costs less than adding a second compressor later 3. Choose the compressor type based on air volume, project length, and desired maintenance intervals 4. Factor in air compressor duty cycle appropriate to compressor type to determine compressor size 5. Determine if an air dryer is required and how much additional air will be required for dryer Flow rate and air consumption curves Each pump model has its own flow rate, lift and air consumption curves that should be based on actual testing, not calculated values 1. Use the pump flow curves to find the flow rate at the desired depth 2. Use the air consumption curve to find the air volume required 3. Multiply this factor by the desired pump flow rate to determine the air consumption per pump 4. Multiply the air consumption per pump by the number of pumps to determine compressor size

10 10 Air compressor types Reciprocating piston compressors are the most common type used. They generally have lower capital cost and are slightly more energy efficient, but are larger, have a lower duty cycle, create more noise and vibration, and require more maintenance over time. Rotary screw compressors are smaller, quieter, and have a 100% duty cycle. They use 5-10% more energy, but maintenance is less frequent and therefore less expensive. Reciprocating Air Compressor Rotary Screw Air Compressor Do I need an air dryer? Air dryers remove condensed moisture from the air system downstream of the compressor to protect air lines, fittings and pressure regulators from damage by corrosion or freezing Should be used at all sites with high humidity (regardless of temperature) and in any climate where ambient temperatures drop below 32 F (0 C)

11 11 Air dryer systems Select an air dryer that will achieve a dew point temperature of 20 F (7 C) below the minimum operating temperature anticipated Refrigerant air dryers are capable of drying air to 35 F (2 C) and don t consume any air from the compressor. Typically used in warm, humid climates where freezing conditions don t occur Refrigerant Air Dryer Desiccant air dryers are capable of drying air to -40 F (-40 C) but consume 15% of the available air from the compressor. Recommended for winter climates. Desiccant Air Dryer QED Flow Rate & Air Consumption Calculator QED s latest web-based tool to help you select the pump that meets your flow rate needs and determines the air system size Input factors for well depth, any additional lift above the well cap, and the desired flow rate The calculator will display the maximum achievable flow rate and the air volume required per pump Entering the number of pumps will display the air compressor size with or without an air dryer qedenv.com/flowratecalculator

12 12 Discharge line sizing and materials 1 (25 mm) and 1.25 (32 mm) OD tubing are most common sizes for down-well discharge tubing Larger diameter provides highest flow rate and lower air consumption per gallon/liter of liquid pumped Surface discharge tubing is typically UV-resistant nylon or HDPE Surface discharge sizing as well as air line diameter can be determined using on-line pipe flow calculators Jacketed tubing or rubber hose? Jacketed Nylon-12 Tubing All lines bundled together, easier to manage High temperature rated to 180 F (82 C) High chemical resistance to many organics Lighter than hose yet very strong Won t kink easily, won t double over in well More economical than rubber hose (40% less) Fuel-Resistant Industrial Rubber Hose Greater bend radius than tubing, can be easily coiled at surface for pump depth adjustment More flexible in very cold weather applications Easier to remove from barbed fittings Resistant to most solvents and fuel additives Used mostly for GW remediation applications Jacketed Nylon-12 Tubing Industrial Rubber Hose

13 13 Easy Fittings faster and safer Maintenance often requires removing pump tubing Cutting tubing and clamps from barb fittings can be difficult, time consuming, poses a safety risk, and shortens tubing length 2-3 (5-8 cm) each time Easy Fittings are high-flow quick connects with quick-release retainer clips Made of high-quality stainless steel alloys with double Viton O-ring seals Saves valuable field time and cost LESS than conventional quick-connect fittings Quick flange removal with the Easy Bolt Removing flange bolts can be a slow and difficult task. Galvanized and plated bolts corrode, and stainless steel bolt threads can gall and seize, often requiring bolts to be cut off and replaced. Easy Bolts fit standard flange holes and tighten using a simple lever action No tools required forget the wrenches and saws! High-grade investment cast stainless steel Only four Easy Bolts needed for 6 & 8 flanges Save labor expense plus replacement bolt cost

14 Air filter/pressure regulator Filter/regulators are installed at each well to protect the pump air valves from large solids and allow for pressure adjustment The regulator allows air pressure to be adjusted to reduce the discharge rate at that well if desired The filter captures solids that may be downstream of the air compressor filter, such as dirt that enters during installation or during routine pump service Moisture is also trapped by the filter, which has an auto-drain valve on the bottom to release water periodically during operation Cycle counter Used to estimate the liquid volume pumped from the well The counter advances one digit with each discharge cycle Multiply the cycle counts by the volume per discharge cycle for your pump model to determine the total volume Also useful for observing pump operation, relative flow rate increase/decrease, and for scheduling maintenance based on total cycles of operation Not subject to scaling or corrosion in leachate or contaminated water like traditional flow meters 14

15 Slowing down the rate at which the pump fills will reduce the rate at which liquid enters the well, which can help reduce the accumulation of silt in the well. Slow fill valve The slow fill valve is installed on the well cap/flange in the air exhaust line and works by controlling the rate at which air is vented from the pump, reducing the fill rate The overall flow rate of the pump will be reduced, since the fill cycle time will be extended Exhaust air equalization valve Installed in the exhaust line below the well cap/flange with exhaust terminated outside the well. Approximately 90% to 95% of the exhaust air is vented through the valve and outside the well. When exhaust line pressure is equal to atmospheric pressure outside the well, the spring loaded valve closes and allows vacuum to be applied to the exhaust line, thereby allowing the liquid level to be pumped down as low as possible. 15

16 Excess Air Flow Valve (auto air shutoff) The Automatic Air Flow Shutoff Valve is a safety feature used in landfill gas wells to prevent pumping air into the well should the air line be ruptured by fire, high temperature or physical damage. The valve is preset to allow the pump to operate at maximum flow under normal operating conditions but will close if the flow exceeds the trigger point. The valve must be manually reset to resume normal operation. Options to improve operation and reduce maintenance in tough applications Teflon-Wrapped Float Entire float assembly is coated with a thin Teflon sheath Greatly reduces build-up of solids on the float, which can extend maintenance intervals Speeds cleaning and reduces chance of damaging float during cleaning 16

17 17 Options to improve operation and reduce maintenance in tough applications Wide Slotted Float Used in wells with very high suspended solids Actuator rod slot is wider and extends through entire float body to prevent build-up Can be retrofit to existing pumps (contact Customer Service for details) Standard Float Wide Slot Float Options to improve operation and reduce maintenance in tough applications Silt and Foam Filter Designed to reduce solids loading in pumps to improve performance and extend maintenance intervals Threads onto pump inlet assembly (replaces standard inlet screen) Filter pad material can be cleaned or replaced Can also improve pump performance and reduce leachate emitting from external exhaust line in wells with foaming leachate

18 18 AutoPump AP4+ * Design Features Easier disassembly: removing four bolts on bottom inlet allows complete pump disassembly in minutes no turning of the inlet assembly or O-ring hang-up/dragging Easier service: quick-release clip on actuator rod allows quick float removal for easier cleaning. Pump body has a high-polish ID finish to reduce solids build-up and precision bore sizing to improve O-ring fit Increased durability: All metal parts are 304SS or higher for improved corrosion resistance; plastic parts are high-strength & hightemperature engineering plastics (PVDF, PEEK) Increased warranty: 5-year full warranty with no pro-rating in later years * Patent Pending QED AutoPump AP4+ Advantages Widest range of pump models and accessories available to handle difficult landfill pumping environments Longer warranty than other types of pumps (5 years) Easier to disassemble for cleaning than other designs All of this comes from QED, the originator of air-powered pumps for landfills, remediation and groundwater sampling Over 100,000 AutoPump systems installed since 1986 Manufactured in the USA Midwest & West Coast Experienced Application Specialists (18 years average) Toll-Free Customer Service and Tech Support Local QED Reps in USA, 20 international distributors Multi-million dollar inventory to meet fast delivery needs

19 19 What to consider when purchasing a pump The bitterness of poor quality remains long after the sweetness of low price is forgotten. Experienced application specialists Warranty length and coverage Designed for serviceability Cast components vs. machined parts Pump weight & ease of removal Ease of disassembly Customer Service and Support Full O&M manual provided with pump Availability of repair parts Troubleshooting & repair phone support Local field service and support availability Machined inlet housing parts must be assembled, higher corrosion potential Webinars, training and online resources One-piece cast stainless steel inlet has increase corrosion resistance, easier to service Questions? David Kaminski QED Environmental Systems, Inc. info@qedenv.com Toll-Free Numbers Ann Arbor, MI: San Leandro, CA: Website

Choosing the Right Air-Powered Pump for Your Landfill Pumping Application

Choosing the Right Air-Powered Pump for Your Landfill Pumping Application Choosing the Right Air-Powered Pump for Your Landfill Pumping Application David Kaminski QED Environmental Systems Inc. Ann Arbor, MI / San Leandro, CA Copyright QED Environmental Systems, Inc. 2014; all

More information

The pump. A pump is a device that moves fluids (liquids or gases), or sometimes slurries, by mechanical action.

The pump. A pump is a device that moves fluids (liquids or gases), or sometimes slurries, by mechanical action. The pump A pump is a device that moves fluids (liquids or gases), or sometimes slurries, by mechanical action. Pumps operate by some mechanism (typically reciprocating or rotary), and consume energy to

More information

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY PUMPS WITH MOTORS 1. No assembly required. Unpack the pump and motor and examine for any

More information

CFH Series High Efficiency Filters

CFH Series High Efficiency Filters CFH Series High Efficiency Filters Intelligent Air Technology Save energy, dollars & protect your air system The Compressed Air Challenge, a government/ industry sponsored energy savings awareness program,

More information

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, Dual-Purpose Water Supply, Domestic and Fire Sprinkler System General Description

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, Dual-Purpose Water Supply, Domestic and Fire Sprinkler System General Description Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, Dual-Purpose Water Supply, Domestic and Fire Sprinkler System General Description The TYCO RAPID RESPONSE Model

More information

Page 1 of 18. Part# /5/2013

Page 1 of 18. Part# /5/2013 Part# 1002655-06 8/5/2013 This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly and keep for future reference INSTRUCTIONS

More information

KTV DEWATERING PUMPS

KTV DEWATERING PUMPS www.tsurumi-global.com DEWATERING PUMPS Submersible Lightweight Compact Dewatering Pumps Tsurumi -series features submersible pumps of lightweight compact design. The pump body is made of die-casted aluminium

More information

J-PRO-24 Pump Chlorinator. Installation & Start-Up Guide

J-PRO-24 Pump Chlorinator. Installation & Start-Up Guide J-PRO-24 Pump Chlorinator Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance, your system will be providing treated water

More information

Environmental Design The tank has separating devices at the exhaust port to prevent oil-spraying and to reduce pollution.

Environmental Design The tank has separating devices at the exhaust port to prevent oil-spraying and to reduce pollution. As a specialized enterprise in making vacuum pumps, we have devoted ourselves to satisfy our customers need for high quality products. We adopt the latest designs and technology to make sure that our products

More information

MACHINE SHOP ACCESSORIES CLEVER, TIME-SAVING PRODUCTS TO MAKE YOUR LIFE EASIER

MACHINE SHOP ACCESSORIES CLEVER, TIME-SAVING PRODUCTS TO MAKE YOUR LIFE EASIER MACHINE SHOP ACCESSORIES CLEVER, TIME-SAVING PRODUCTS TO MAKE YOUR LIFE EASIER ROYAL R8 QUICK-CHANGE TOOLING SYSTEM Unit only protrudes 11 8" beyond spindle. 1. Loading the Quick-Change Body into a standard

More information

Full-line Product Overview

Full-line Product Overview Full-line Product Overview End Suction Centrifugal Pumps This general purpose pump can be configured in frame-mounted and close-coupled, semi-open and enclosed impeller configurations. They are available

More information

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax Part# 1000692 7/12/99 tn INSTRUCTIONS This manual contains important information concerning the installation and operation of the gun washers listed at the right. Read manual thoroughly and keep for future

More information

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features. Spot Cooling Systems, Inc. 120 Century Drive Suite 00 Carrollton, TX 7006 00-6-776 Operation Manual SCT1B and SCT1B Warning! Improper installation, adjustment, alteration, service, or maintenance can cause

More information

High Inlet Temperature Air Dryer. Desiccant Air Dryer. Membrane Air Dryer After-Clooler. Air Filter. Oil-Water Separator Automatic Drain Value

High Inlet Temperature Air Dryer. Desiccant Air Dryer. Membrane Air Dryer After-Clooler. Air Filter. Oil-Water Separator Automatic Drain Value High Inlet Temperature Air Dryer Membrane Air Dryer After-Clooler Oil-Water Separator Automatic Value 1 2 3 4 5 6 7 8 9 1 HYD model Control Panel 1. on HYD-150 and smaller - It is equipped with a low pressure

More information

IQ/OQ Protocol Installation Qualification/ Operation Qualification

IQ/OQ Protocol Installation Qualification/ Operation Qualification IQ/OQ Protocol Installation Qualification/ Operation Qualification ZZ FreeZone Freeze Dry Systems (To be used with some FreeZone Systems manufactured prior to August, 2004- see model number chart inside)

More information

Contents. Eye/Face Washes... 3 Eyewashes... 3 Swing-Away Eyewashes... 4 Eyewash/Drench Hose Units... 4 Emergency Showers... 4 Safety Stations...

Contents. Eye/Face Washes... 3 Eyewashes... 3 Swing-Away Eyewashes... 4 Eyewash/Drench Hose Units... 4 Emergency Showers... 4 Safety Stations... Contents Eye/Face Washes... 3 Eyewashes... 3 Swing-Away Eyewashes... 4 Eyewash/Drench Hose Units... 4 Emergency Showers... 4 Safety Stations... 5 Portable Eyewashes... 5 Faucet Mounted Eyewashes... 6 Barrier-Free

More information

SECTION AIR COMPRESSORS AND ACCESSORIES

SECTION AIR COMPRESSORS AND ACCESSORIES PART 1 GENERAL 1.01 WORK INCLUDED SECTION 11370 AIR COMPRESSORS AND ACCESSORIES A. This specification includes air compressors with air dryers. B. Furnish, install, start-up, and test air compressors and

More information

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...

More information

POWERFUL CUSTOMIZED SOLUTIONS UNMATCHED QUALITY

POWERFUL CUSTOMIZED SOLUTIONS UNMATCHED QUALITY Vactor celebrates over 45 years as your powerful sewer cleaning partner. For nearly 50 years, Vactor Manufacturing has been the leader in building combination sewer cleaners with technological innovation

More information

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com Read and Save These Instructions Horizon Galaxy - Installation and Operations Manual Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC 27505 www.horizondehumidif iers.com 1 Safety Notes: The Horizon

More information

Please Read and Save These Instructions.

Please Read and Save These Instructions. Page 1 of 8 RadonAway Ward Hill, MA. GP500 Fan Installation Instructions Please Read and Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL SERVICE

More information

Module 7: Air Supply System

Module 7: Air Supply System Terms and Definitions Components of the Air Supply System Basic Functions of the Air Supply System Parts of a Compressor Characteristics of Compressors Loading and Unloading Process Characteristics of

More information

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series Pamphlet A2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment

More information

Models: GW/R-T GW/R-2-T GW/R-3-T

Models: GW/R-T GW/R-2-T GW/R-3-T Part# GW/R-T-OM 1/12/04 TN Models: GW/R-T GW/R-2-T GW/R-3-T This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly

More information

Air Eliminator

Air Eliminator Cat alog Title Catalog Subtitle 730-20 Air Eliminator Principle Operation & Maintenance Manual Page 2 Table of Content Safety Warning Symbols 2 Air Elimination Principle 2 Air Eliminator Principle (Continuted)

More information

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job SERIES Commercial, Forced Draft, Hot Water or Steam Boiler Sizes from to,8 MBH output The right fit for any commercial job The Series is built to handle any installation - businesses, institutions, apartments,

More information

Nirvana. Cycling Refrigerated Dryers

Nirvana. Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Reliability Is Our Design Ingersoll Rand's Nirvana Cycling Refrigerated Dryer provides reliability like no other dryer in its class:

More information

Pressure Washers (courtesy of Mi-T-M Corp.)

Pressure Washers (courtesy of Mi-T-M Corp.) Pressure Washers (courtesy of Mi-T-M Corp.) What is pressure washing? Pressure washing or power washing is the growing practice of cleaning using high pressure water spraying. The high pressure water spraying

More information

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH TXV Horizontal Slab Coils WLSH These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system

More information

Twin-Agent Fire Fighting/Securing Systems Specifications

Twin-Agent Fire Fighting/Securing Systems Specifications Twin-Agent Fire Fighting/Securing Systems Specifications Models 450/50, 450/100, 900/100 & 1350/200 INDEX 1.0 GENERAL 1.1 References 1.2 Submittals 1.3 System Capabilities 1.4 Quality Control 1.5 Warranty,

More information

Big-Lock Tubing. Total Solutions for Air, Vacuum and Inert Gas Systems

Big-Lock Tubing. Total Solutions for Air, Vacuum and Inert Gas Systems Big-Lock Tubing Total Solutions for Air, Vacuum and Inert Gas Systems 2 High Quality Aluminum Piping Systems Simply stated there is no equal. Big-Lock from Gardner Denver has taken large diameter piping

More information

SECTION air supply system + WARNING: + NOTE: GENERAL DESCRIPTION COMPRESSED AIR RESERVOIRS / 1.

SECTION air supply system + WARNING: + NOTE: GENERAL DESCRIPTION COMPRESSED AIR RESERVOIRS / 1. 08-000.02/ 1 2011JA14 SECTION 08-000.02 GENERAL DESCRIPTION See Figure 1 for a schematic diagram of the. See the Nova LFS parts manual for a detailed schematic of the. The function of the vehicle s is

More information

Dual Column Dehydrating Breather Manual

Dual Column Dehydrating Breather Manual Dual Column Dehydrating Breather Manual DCB-MANUAL 1.6 Read and understand this manual prior to operating or servicing the products. SPX Transformer Solutions, Inc., Service & Components Division U.S.

More information

CHILLER. Operator s & Installation Manual

CHILLER. Operator s & Installation Manual CHILLER MODEL: CFF-500 Operator s & Installation Manual Release Date: November 3, 1996 Publication Number: 90667 Revision Date: May 10, 2010 Revision: E Visit the IMI Cornelius web site at www.cornelius.com

More information

HOMA Pump, Ansonia Connecticut

HOMA Pump, Ansonia Connecticut TM High Performance in HOMA began as a submersible motor manufacturer more than fifty years ago. We expanded into full pump production in the 1960s. Every product we design and manufacture has always exceeded

More information

H O B A R T F T F L I G H T - T Y P E W A R E W A S H E R. Energy efficient. Water efficient. Cleaning efficient. So you re efficient.

H O B A R T F T F L I G H T - T Y P E W A R E W A S H E R. Energy efficient. Water efficient. Cleaning efficient. So you re efficient. H O B A R T F T 9 0 0 F L I G H T - T Y P E W A R E W A S H E R Energy efficient. Water efficient. Cleaning efficient. So you re efficient. 2 H O B A R T F T 9 0 0 F L I G H T - T Y P E W A R E W A S H

More information

SYSTEMS for CATALYTIC FILTERS

SYSTEMS for CATALYTIC FILTERS OP40U5F, OP40B5F, OP80U10F, OP80B10F, OP120U15F & OP120B15F INSTALLATION, OPERATION & SERVICE INSTRUCTIONS Hydrogen Sulfide Removal SYSTEMS for CATALYTIC FILTERS NO DIAPHRAGMS OR AIR CELLS COMPLETELY CORROSION

More information

PRO 2000i LOW LEVEL DEPOSITOR

PRO 2000i LOW LEVEL DEPOSITOR DEPOSITORS AND AUTOMATED CAKE PRODUCTION SYSTEMS PRO 2000i LOW LEVEL DEPOSITOR OPERATION AND SPARE PARTS MANUAL Serial No. PR2L- (Please quote this number when ordering spares, and making service calls)

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ,t_2007 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS CH33 Series Units EVAPORATOR 505,264M (65484504) 10/07 Supersedes 09/06 COILS n _putech blications ical Litho U.S.A. RETAIN THESE

More information

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD TXV Horizontal Duct s EHD These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system

More information

SEWAGE PUMPS WITH CUTTER IMPELLER

SEWAGE PUMPS WITH CUTTER IMPELLER www.tsurumiglobal.com C SEWAGE PUMPS WITH CUTTER IMPELLER Submersible Sewage Pumps with Impeller Performance Range Tsurumi Cseries pumps are heavyduty, submersible cutter pumps for sewage and wastewater,

More information

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X INSTALLATION INSTRUCTIONS Cased N, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service,

More information

J-PRO-24 Soda Ash Injection Installation & Start-Up Guide

J-PRO-24 Soda Ash Injection Installation & Start-Up Guide J-PRO-24 Soda Ash Injection Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance, your system will be ph neutral water

More information

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD TXV Horizontal Duct s EHD These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system

More information

Condensing Unit Installation and Operating Instructions

Condensing Unit Installation and Operating Instructions Bulletin WCU_O&I 01 June 2003 Condensing Unit Installation and Operating Instructions WCU Air Cooled Condensing Unit Table of Contents Section 1. Section 2. Section 3. Section 4. Section 5. Section 6.

More information

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw SEMI-INSTANTANEOUS ENERGY: STEAM TO WATER U-TUBE SINGLE-WALL & DOUBLE-WALL HEAT EXCHANGERS FLOOR DRAIN Typical Construction Figure 34-1 FLOOR DRAIN 1. U-tube

More information

SECTION STEAM CONDENSATE PUMPS

SECTION STEAM CONDENSATE PUMPS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 22 23 STEAM CONDENSATE PUMPS SPEC WRITER NOTES: 1. Delete between // ---- // if not applicable to project. Also delete any other item or paragraph not applicable

More information

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY Unpack pump from carton and check for shipping damage. WARNING: Magnetic field hazard. This pump

More information

UltraHeat Plate and Frame Heat Exchangers. Engineered for Excellence

UltraHeat Plate and Frame Heat Exchangers. Engineered for Excellence UltraHeat Plate and Frame Heat Exchangers Engineered for Excellence Graham Corporation traces its history to the earliest development of heat transfer products in the United States during the 1920s, when

More information

SECTION AIR COMPRESSORS AND ACCESSORIES

SECTION AIR COMPRESSORS AND ACCESSORIES PART 1 GENERAL 1.01 WORK INCLUDED SECTION 11370 AIR COMPRESSORS AND ACCESSORIES A. This specification includes air compressors with air dryers. B. Furnish, install, start-up, and test air compressors and

More information

Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies

Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies SprinkFLEX Stainless Steel Sprinkler Fittings connect the branch line to the sprinkler using a flexible stainless

More information

HYDROGEN SULFIDE REMOVAL SYSTEMS

HYDROGEN SULFIDE REMOVAL SYSTEMS OX120U5, OX120U10 OX120B5, OX120B10 OX120U10R & OX120U5R INSTALLATION, OPERATION & SERVICE INSTRUCTIONS HYDROGEN SULFIDE REMOVAL SYSTEMS NO MEDIA NO CHEMICALS NO WASTE PRESSURE BOOSTING SYSTEM MODELS:

More information

J-PRO-22 Pump Proportional Feed Hydrogen Peroxide Installation & Start-Up Guide

J-PRO-22 Pump Proportional Feed Hydrogen Peroxide Installation & Start-Up Guide J-PRO-22 Pump Proportional Feed Hydrogen Peroxide Installation & Start-Up Guide Thank you for purchasing a Clean Water System! Please review this start-up guide entirely before beginning to install your

More information

Practic - HLE. Piston Compressors 2 TO 10 HP 6 TO 500 LITRES

Practic - HLE. Piston Compressors 2 TO 10 HP 6 TO 500 LITRES Practic - HLE Piston Compressors 2 TO 10 HP 6 TO 500 LITRES ALUP Driven by technology. Designed by experience. ALUP Kompressoren has over 90 years of industrial experience. It is our ambition to offer

More information

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...

More information

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS ANSUL Twin-Agent Fire Fighting/Securing Systems Specifications Models 450/50-B, 450/100-B, 900/100-B INDEX 1.0 GENERAL 1.1 References 1.2 Submittals 1.3 System Capabilities 1.4 Quality Control 1.5 Warranty,

More information

GSZ/GSD HIGH VOLUME DEWATERING PUMPS

GSZ/GSD HIGH VOLUME DEWATERING PUMPS www.tsurumi-global.com / HIGH VOLUME DEWATERING PUMPS Submersible High Volume Dewatering Pumps Tsurumi and series of submersible heavy-duty pumps deliver high volume discharge. This former consists of

More information

Series 57 WATER/OIL SEPARATORS

Series 57 WATER/OIL SEPARATORS Series 304 WATER AND OIL IN COMPRESSED AIR SYSTEM WATER ACCUMULATION When compressing air, a compressor draws in many other substances including water vapor. The compression process causes this water vapor

More information

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314) DRY AIR SYSTEMS, INC. 2655 Metro Boulevard Maryland Heights, Missouri 63043 (314) 344-1114 fax (314) 344-0677 HD SERIES DRIERS TABLE OF CONTENTS WHY AN AIR DRYER 3 WHAT IS A DESICCANT AIR DRYER 3 Desiccant

More information

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA TXV Coils for Manufactured Housing EMA NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance,

More information

Water Distribution Study Guide Class III (Made available by: Kansas Rural Water Association)

Water Distribution Study Guide Class III (Made available by: Kansas Rural Water Association) Water Distribution Study Guide Class III (Made available by: Kansas Rural Water Association) 1. Which one of the following types of pumps works on the basis of inertia or mass moving in a circular motion?

More information

EVAPORATIVE COOLER PUMPS

EVAPORATIVE COOLER PUMPS EVAPORATIVE COOLER PUMPS ebmpapst Evaporative Cooler Pump EBMALPHA $144.65 @ 1. metre Head @ 2. metre Head Power Supply 32 litres/min 25 litres/min 24V/1/5Hz Nominal Watts 5 watts Outlet Connection 2mm

More information

Daikin Water Cooling, Heating, and High Capacity Booster Coils

Daikin Water Cooling, Heating, and High Capacity Booster Coils Installation and Maintenance Manual IM 900 Daikin Water Cooling, Heating, and High Capacity Booster Coils Group: Applied Air Part Number: IM 900 Date: February 2008 Types HI-F5, E-F5 2008 Daikin International

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL HOT WATER HEATING BOILERS DOMESTIC WATER HEATERS 150,000-300,000 Btu/hr MODELS EB-EWU-02 IMPORTANT INSTALLER - AFFIX INSTALLATION MANUAL ADJACENT TO THE BOILER CONSUMER - RETAIN

More information

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS INSTRUCTION MANUAL FOR WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS DE3 - DE5 OPERATIONS GENERAL This instruction manual covers the installation, operation, maintenance and troubleshooting

More information

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products Smart Solutions for Drying Compressed Air Single Tower Heat Reactivated Desiccant Air Dryer TM HS Dryer 800.943.794 www.engineeredairproducts.com Engineered Air Products Understanding Compressed Air Moisture

More information

Screw Compressors. AS Series. Capabilities from: 64 to 143 cfm Pressures from: 80 to 217 psig. kaeser.com

Screw Compressors. AS Series. Capabilities from: 64 to 143 cfm Pressures from: 80 to 217 psig. kaeser.com Screw Compressors AS Series Capabilities from: 64 to 143 cfm Pressures from: 80 to 217 psig kaeser.com AS Series Built for a lifetime. Kaeser Compressors has pushed the boundaries of compressed air efficiency

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings. SECTION 15481 COMPRESSED AIR SYSTEM PART 1 - GENERAL 1.1 SECTION INCLUDES A. Pipe and pipe fittings, including valves, unions and couplings. B. Air compressor. C. After cooler. D. Refrigerated air dryer.

More information

Desiccant Breathers: A Front Line Defense in the War on Contamination

Desiccant Breathers: A Front Line Defense in the War on Contamination LE White WHITE PAPER Paper : A Front Line Defense in the War on Contamination 2015 Lubrication Engineers, Inc. The Lubrication Reliability Source 1 www.lelubricants.com 800-537-7683 Introduction Are you

More information

Our Know-How. Your Peace of Mind. Steam Solutions

Our Know-How. Your Peace of Mind. Steam Solutions Our Know-How. Your Peace of Mind. Steam Solutions Steam Solution Know-How Our team of specialists have years of experience in planning and engineering. This knowledge, combined with our valuable manufacturer

More information

Geothermal Flow Centers. Simply Smart. boschheatingandcooling.com

Geothermal Flow Centers. Simply Smart. boschheatingandcooling.com Geothermal Flow Centers Simply Smart Bosch Geothermal Flow Centers are built for easy, timesaving installation and available in a wide variety of combinations to suit your needs. boschheatingandcooling.com

More information

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton G Series ENCASED/UNCASED AIR COILS Geothermal/Water Source Heat Pumps R-410A Refrigerant 2- Ton Dimensional Data G Series Air Coils Installation ti Manual Installation Information Maintenance IM1018AG1

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET General Piping Recommendations and Refrigerant Line Length for Split-System Air Conditioners and Heat Pumps GENERAL GUIDELINES This Split-System (Air Conditioning Condensing/Heat

More information

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel: www.watsonmcdaniel.com 428 Jones Boulevard Limerick Airport Business Center Pottstown PA 19464 Tel: 610-495-5131 129 Return Introduction Return System Shown below is a simplified view of a steam system

More information

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is immediately

More information

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series Pamphlet M2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment

More information

Lowering Application Intensity

Lowering Application Intensity Lowering Application Intensity 1 Intensity Lowering Application 2 (a view on instantaneous area of coverage) Providing the largest area of instantaneous coverage possible, minimizes the impact on the soil

More information

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer Smart Solutions for Drying Compressed Air Dual Tower Heat Reactivated Desiccant Air Dryer HR Heated HB Blower 800.943.794 www.engineeredairproducts.com Engineered Air Products Moisture in compressed air

More information

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model BWXP OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER Electric Heater Company Base Model "BWXP" HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203)

More information

Building air conditioning systems using Ice-Cel thermal storage can be designed which cost little or no more than conventional chiller-only systems.

Building air conditioning systems using Ice-Cel thermal storage can be designed which cost little or no more than conventional chiller-only systems. WHY THERMAL STORAGE? Thermal storage is a technology that has come of age. It meets today's need for flexible energy management. Whether you're the owner of a large building, a school executive, a hospital

More information

VAC-U-DRY VACUUM DEHYDRATOR

VAC-U-DRY VACUUM DEHYDRATOR VAC-U-DRY VACUUM DEHYDRATOR Remove Free & Dissolved Water down to 20 PPM (0.002%) Flow range 5~60 gpm,19~225 lpm Visually Monitor Fluid and Process through Clear Chamber Covers High Operating Vacuum and

More information

RDT Refrigeration Book

RDT Refrigeration Book RDT Refrigeration Book Indoor / Outdoor Air-Cooled Systems Indoor Air-Cooled Systems 1. Shorter line runs. 2. Systems located off roof or dock space. 3. Weather covers are not required (saves cost). 4.

More information

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series Pamphlet U2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment

More information

Burner Comparisons. Typical Competitor s Burner

Burner Comparisons. Typical Competitor s Burner Burner Comparisons INOV8 s Typical Competitor s Burner Automatic nozzle cleanout Yes No Available BTUs rated as input 100,000 to 1,000,000 76,500 to 500,000 Burner Motor - hp 1/5 1/7 Combustion safety

More information

Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges

Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges TM High Performance in Wastewater Pumping HOMA submersible water and wastewater pumps operate worldwide in numerous domestic, municipal

More information

Operation and Maintenance Haskris LX-Series, R-Series, WW-Series, OPC-Series

Operation and Maintenance Haskris LX-Series, R-Series, WW-Series, OPC-Series Section 1: Temperature Control Your Haskris will have one of three different types of controller. Use table 1-1 to identify the relevant controller. The controller may appear different than examples. Contact

More information

SCFM REFRIGERATED COMPRESSED AIR DRYERS. CRN Series

SCFM REFRIGERATED COMPRESSED AIR DRYERS. CRN Series 10 3000 SCFM REFRIGERATED COMPRESSED AIR DRYERS CRN Series Durability Delivered Champion CRN Series refrigerated air dryers are engineered to benefit you today and tomorrow. Quality components and engineering

More information

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

Chiller Plant Design. Julian R. de Bullet President debullet Consulting Chiller Plant Design Julian R. de Bullet President debullet Consulting 703-483-0179 julian@debullet.com This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer ASHRAE

More information

LONG LINE SET APPLICATION R-410A

LONG LINE SET APPLICATION R-410A LONG LINE SET APPLICATION R-410A TECHNICAL PUBLICATION TP-107K Goodman Company, L.P. INDEX SECTION 1. General Requirements for All Long Line Set Applications... 2 SECTION 2. Outdoor Unit and Indoor Unit

More information

Cast Line Heaters The Benefits of This Space Saving Electric Heater

Cast Line Heaters The Benefits of This Space Saving Electric Heater WHITE PAPER Cast Line Heaters The Benefits of This Space Saving Electric Heater Introduction Cast line heaters, or cast-in heaters, offer an alternative to the more common inline process heaters that have

More information

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D Technical Data SD 9902D SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 PRINTED IN U.S.A. SD 79902D/9803 Condensate Commander Pump Dimensions Weight Size A B C D E* F Lbs. 1"x

More information

SPECIFICATIONS MODEL E859C MINI DEHYDRATOR

SPECIFICATIONS MODEL E859C MINI DEHYDRATOR SPECIFICATIONS MODEL E859C MINI DEHYDRATOR 1 DEHYDRATION TECHNOLOGY This proposal describes the equipment which shall be supplied by ENERVAC for a system for processing (dehydrating, de-aerating, purifying

More information

NT1-P CONDENSATE NEUTRALIZATION TANK WITH PUMP INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

NT1-P CONDENSATE NEUTRALIZATION TANK WITH PUMP INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS NT1-P CONDENSATE NEUTRALIZATION TANK WITH PUMP INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS NOTE - Check with your local water authority for regulations regarding discharge of treated condensate

More information

Single Tower Heat Reactivated Desiccant Air Dryer

Single Tower Heat Reactivated Desiccant Air Dryer Single Tower Heat Reactivated Desiccant Air Dryer iste Dryer Understanding Compressed Air Moisture in compressed air is damaging. Using untreated air results in water and contaminants in your air lines,

More information

Portable Purification zf04 Systems Models PVS 185, 600, 1200, 1800, 2700

Portable Purification zf04 Systems Models PVS 185, 600, 1200, 1800, 2700 Portable Purification zf04 Systems Models PVS 185, 600, 1200, 1800, 2700 185 Principles of Operation Contaminated oil is drawn into the Parker Portable Purification System by a vacuum of 25 In/Hg. The

More information

Fleck 2510 SXT Catalox Installation & Start Up Guide

Fleck 2510 SXT Catalox Installation & Start Up Guide Fleck 2510 SXT Catalox Installation & Start Up Guide For Catalox Filters with PotPerm Bleach Solution Tank Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance

More information

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps... PUMPS FOR INDUSTRY CONTENTS: The Vertical Pump Specialists Introduction & User List Product Overview Vertical Process Pumps... Series 600 Vertical Sewage Pumps... Series 700 Vertical Sump Pumps... Series

More information

Why is Hutchins Better?

Why is Hutchins Better? Why is Hutchins Better? Unlike imported sanders, Hutchins is an innovator in sanding technology. This means we constantly improve and re-design our sanders to offer the latest advances for performance,

More information

HE120, HE160 Humidifier Installation Kit

HE120, HE160 Humidifier Installation Kit HE120, HE160 Humidifier Installation Kit INSTALLATION INSTRUCTIONS WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and

More information