RLA kw TECHNICAL MANUAL AIR COOLED WATER CHILLERS WITH HELICAL FANS

Size: px
Start display at page:

Download "RLA kw TECHNICAL MANUAL AIR COOLED WATER CHILLERS WITH HELICAL FANS"

Transcription

1 RLA AIR COOLED WATER CHILLERS WITH HELICAL FANS FERROLI adheres to the EUROVENT certification programme. The products concerned appear in the products guide to kw TECHNICAL MANUAL

2 2

3 TABLE OF CONTENTS THIS MANUAL IS DIVIDED INTO SECTIONS. THEIR NAMES APPEAR IN THE HEADING OF EACH PAGE. GENERAL SPECIFICATIONS PRESENTATION OF THE UNIT IDENTIFICATION CODE OF THE UNIT DESCRIPTION OF THE COMPONENTS OPTIONS AND ACCESSORIES MECHANICAL ACCESSORIES DESCRIPTION OF THE CONFIGURATIONS ELECTRICAL ACCESSORIES MECHANICAL OPTIONS ELECTRICAL OPTIONS COMBINATIONS OF ACCESSORIES-MODELS TECHNICAL SPECIFICATIONS AND STANDARD PERFORMANCES - R407C TECHNICAL SPECIFICATIONS OF UNIT AB-7M NOISE LEVELS STANDARD PERFORMANCES AB-7M TECHNICAL SPECIFICATIONS OF UNIT AS-7M NOISE LEVELS OF THE UNIT STANDARD PERFORMANCES AS-7M OPERATING RANGE OPERATING RANGE HOW TO SELECT THE UNIT WATER PRESSURE DROP WORKING HEAD MAXIMUM VOLUME OF WATER MAXIMUM VOLUME OF WATER IN THE SYSTEM WITH WET MODULE OVERALL DIMENSIONS - MINIMUM SPACE REQUIRED AND WEIGHTS OVERALL DIMENSIONS DESCRIPTION OF THE COMPONENTS MINIMUM SPACE REQUIRED FOR OPERATION POSITION OF WET CONNECTIONS MOD POSITION OF WET CONNECTIONS MOD WEIGHT DISTRIBUTION DURING OPERATION

4 GENERAL SPECIFICATIONS Presentation of the unit This new series of industrial chillers has been designed to meet the air conditioning requirements of medium-large systems in the industrial, service and business sectors. Suitable for outdoor installation, they are built for various types of system and to comply with the needs of highly qualified planning engineers. The complete series for use in hydronic systems includes six sizes with refrigerating power ratings ranging from 149 to 311 kw. When the units were designed, particular attention was also paid to sound emission in our endeavour to comply with the increasingly more restrictive laws governing acoustic pollution: all the sizes are therefore available in both the basic and silenced versions, to choose depending on the noise level required. All the units can produce cold water at a temperature between 5 and 10 C and are also pre-engineered for operation at low outdoor air temperatures thanks to use of a monitoring system through control of the fans by steps. All the units have 2 independent chilling circuits, each of which is equipped with two Scroll compressors. This allows the power generated by the unit to be modulated from 25% to 100%, and to thus adapt to the heat load of the system supplied. All the units are equipped with a thermal barrier plate type evaporator protected by means of a differential water pressure switch and electric antifreeze heater, coils with extended surfaces and extensive heat exchanging areas formed by copper pipes and notched aluminium fins, electric fans with scythe-shaped vanes to reduce the sound emission, electric panel for adjustments and controls, controller with microprocessor. The standard supply can also be integrated with a vast range of electrical and mechanical accessories. The Water Storage Tank and Pumping Module with 1 or 2 Pumps are particularly important accessories. If both are chosen, the tank is configured for storage on the delivery to the system or for storage on the return part of the system, or for storage pre-engineered for the primary and secondary circuit, depending on the type of Pumping Module selected. The chillers have been designed for use with R407C eenvironment-friendly refrigerant. All the units are accurately built and tested individually. Installation only requires electrical and wet connections. Identification code of the unit The codes that identify the units are listed below and include the sequences of letters that determine the meanings for the various versions and set-ups. IR VB - AB M - 5 Type of unit IR - Unit for installation in a Hydronic system, operating as a Chiller Type of Power Supply 5-400V - 3ph+N - 50Hz N of compressors= 4 Size of unit Version of unit VB - Base Version Acoustic Version AB - Basic Version AS - Silenced Version This version includes soundproofing of the compressors and fans with reduced rotation rate Type of Refrigerant 7 - R407C Climatic Limits M - Medium temperatures The unit is suitable for use in places with the average temperatures typical of temperate climates, within limits to use up to C. 4

5 GENERAL SPECIFICATIONS Description of the components 1. Fans. These are the helical type with scytheshaped vanes to increase efficiency and reduce the sound emissions. The fans are directly coupled to the threephase motor by means of an external rotor. Thermal protection against operating faults is installed inside the winding. 2. Electric control and monitoring panel. It is housed in a cabinet made of adequately thick painted sheet metal suitable for outdoor installation (protection degree IP 54). The panel comprises the following main components: Main door-locking circuit-breaker. Disconnectable fuse holders with protection fuses for each compressor Disconnectable fuse holders with protection fuses for the oil heaters of the compressors. 1 2 Disconnectable fuse holders and protection fuses for the antifreeze heater. 3 4 Control contactor for each compressor. Disconnectable fuse holders with fan protection fuses. Fan control contactors. Magnetothermic relay/s and contactor/s for the pump/s (if one of the pumping module accessories is installed). Fan speed control board. Insulating and safety transformer to power the auxiliaries, protected with fuses. Basic monitoring board with microprocessor: the main functions of the monitoring board are: Temperature regulation of the water produced by the unit, operating hour counting for compressors and pump, balancing of operating hours for compressors, start-up timing, parameter entry digitized via the keyboard, alarm diagnosis. Functions associated with the digital inputs: low and high pressure, high compressor discharge temperature (accessory), correct electric power phase presence-sequence, thermal protection for compressors, thermal protection for fans, thermal protection for pump, differential water pressure switch, remote controlled ON/OFF commands. 1 2 Functions associated with the digital outputs: compressor control, water pump control, electric antifreeze heater, general alarm (can be remote controlled). Functions associated with the analog inputs: water inlet and outlet temperatures, circuit 1 and 2 coil temperatures. 3 4 Functions associated with the analog outputs: monitoring of the fan speed by steps in conjunction with the fan control board. 3.User interfacing terminal with display. On-off key. Operating mode selector key. Compressor on-off LED. Antifreeze heaters on LED. Check-control with alarm code display. 5

6 GENERAL SPECIFICATIONS 4. Compressors. These are the SCROLL type with orbiting coil equipped with built-in thermal protection and oil heater. As part of the standard supply, they are positioned on rubber vibration dampers to reduce the vibrations transmitted to the base of the unit. To lower the sound emission of silenced version AS, they are installed in a soundproofed booth made of galvanized sheet metal coated with polyurethane powder paints and covered in soundproofing material. 5. Bearing structure made of galvanized sheet metal coated with polyurethane powder paint to ensure good protection against adverse weather conditions. 6. Water storage tank (accessory that must be requested when the unit is ordered). Made of adequately thick painted sheet metal, this reduces the number of compressor start-ups and fluctuations in the temperature of the water conveyed to the users. It is insulated with thermal barrier insulating material to prevent the formation of condensation and heat exchanges towards the outside. In conjunction with the Pumping Module accessory, it can be supplied in 3 different configurations: Storage on the Delivery, Storage on the Return, Storage pre-engineered for the Primary and Secondary circuit. When the Pipe Kit accessory is used, the only configuration possible is with Storage on the Delivery. The water drain is installed under the tank as part of the standard supply. The water is turned on and off by a cock that allows the unit to be drained. 7 Air vent. The automatic type, turned on and off by a cock and positioned on the highest part of the tank. 8.Water safety valve, on the tank. It acts whenever faulty service leads to an operating pressure in the plumbing system that exceeds the valve opening value. 9.Antifreeze heater connection.1 1/4 female threaded connection pre-engineered for installation of the tank s antifreeze heater. 10. Evaporator, plate type made of braze-welded stainless steel (AISI 316), double chilling circuit and alternate water/refrigerant circuits. It is installed within a shell of thermal barrier insulating material to prevent the formation of condensation and heat exchanges towards the outside. Standard supply also includes a differential pressure switch on the water supply circuit to avoid the risk of freezing if the water flow is shut off for some reason. 11. Condensing coils, the aluminium finned pack type with shaped profile to increase the heat exchange coefficient and with copper pipes arranged in staggered rows. A sub-cooling section is integrated into the lower part. 12. Covering panels, made of galvanized sheet metal coated with polyurethane powder paints to ensure the utmost ability to withstand adverse weather conditions. 6

7 GENERAL SPECIFICATIONS Hydraulic and chilling circuit components 14.Refrigerant safety valve. (Conforms to the Directive governing pressurized vessels -PED). Installed on the delivery pipe of the compressors. It acts if critical service faults should occur. 15.Fluid cock - Gas cock. Allow all the refrigerant in the coils to be pumped and then stored so as to carry out servicing work or to replace all the components of the chilling circuit without having to drain it. 16.Dehydrator filter. Of the removable cartridge type. Retains impurities and traces of moisture in the circuit. 17.Fluid and humidity indicator. Signals when fluid passes through the circuit, indicating that the refrigerant charge is correct. The fluid indicator also changes colour to show the amount of moisture in the refrigerant. 18.Low pressure switch With fixed setting. It is installed on the intake pipe and blocks the compressors of the circuit if the operating pressures drop below the tolerated values. It automatically resets as the pressure increases. If it activates frequently, the circuit will block and can only be restarted by resetting via the user interface terminal. 19.High pressure switch With fixed setting. It is installed on the delivery pipe and blocks the compressors of the circuit if the operating pressures exceed the tolerated values. If it activates, the circuit will block and can only be restarted by resetting via the user interface terminal. 20.Electrical resistors to heat the compressor oil. One per compressor, belt type. It activates when the compressor switches off. Their task is to keep the temperature of the oil sufficiently high so as to prevent refrigerant from migrating during these pauses. 23.Fluid solenoid valve.one per circuit. They shut off when both the compressors of the circuit switch off, preventing liquid refrigerant from flowing towards the evaporator during periods at a standstill. 24.Thermostatic valve. With external equalizer. It s task is to supply the evaporator correctly, keeping the selected degree of superheat at a steady level. High temperature thermostat (accessory). One per compressor, installed on the delivery pipe to protect the individual compressor if the end of compression temperature exceeds 130 C. Differential water pressure switch. This is standard supply and is installed on the connections between the exchanger s water inlet and outlet. It blocks the unit if it activates. Pressure taps: 1/4 SAE (7/16 UNF) type with air pump. Allow the operating pressure of both the circuits to be measured in 3 main points: compressor delivery, flow-restricting component inlet, compressor intake. 7

8 OPTIONS AND ACCESSORIES Mechanical accessories GM (M) Pressure gauge unit. Consisting of 4 pressure gauges that display the pressure of the refrigerant fluid on the intake and delivery of the compressors of both circuits.. GP (M) Protective grilles. Consisting of metal grilles that protect the coils with extended surfaces. AVM (F) Spring vibration dampers. Consisting of 4 spring vibration dampers to install under the unit. They reduce the mechanical vibrations generated by the compressor and fans during their normal operation, and that are then transmitted to the bearing surface of the machine. The insulation degree provided by the vibration dampers is about 90%. SAA (M) Water storage tank. Made of adequately thick painted sheet metal, this reduces the number of compressor start-ups and fluctuations in the temperature of the water conveyed to the users. It is insulated with thermal barrier material to prevent the formation of condensation and heat exchanges towards the outside. The accessory is inclusive of water safety valve, air vent, water drain and antifreeze heater connection. In conjunction with the Pumping Module accessory, it can be supplied in 3 different configurations: Storage on the Delivery, Storage on the Return, Storage pre-engineered for the Primary and Secondary circuit. Pumping module with 1 o 2 Pumps (The second pump, installed in parallel to the first, allows to have one workable pump to use if the first doesn't work).: Besides the pumps, this accessory is equipped with all the hydraulic components (water filter, expansion tank, on-off valves, water pressure gauge) required for complete installation and easy maintenance. Different water accumulation tank configurations are therefore available in combination with the pumping module accessory: MP-AM : Storage on the water supply plant Delivery (1) : The pump draws water from the supply plant, sends it to the plate type heat exchanger and then to the inertial storage tank. In this configuration, when the pump operates in its nominal conditions, it is able to supply the circulating water with a residual head of about 120 to 210 kpa (from 12 to 21 m.w.c). MP-AR: Storage on the water supply plant Return (1) : The pump draws water from the inertial storage tank, sends it to the plate type heat exchanger and then to the system. In this configuration, when the pump operates in its nominal conditions, it is able to supply the circulating water with a residual head of about 120 to 210 kpa (from 12 to 21 m.w.c). MP - PS: Storage pre-engineered for the primary and secondary circuit. The pump s sole task is to allow water to circulate around the primary circuit: this circuit includes the storage tank and plate type heat exchanger (chiller s water circuit). Assembly of the pumping section for the secondary circuit is at the installer s charge and includes the storage tank (with pre-engineered wet connections) and the system to be supplied. KT - Pipe kit, consists of two steel pipes insulated with heat barrier material. If the Pumping Module accessory is not installed, the pipe kit is obligatory to be taken. Notes: (1): Refer to the respective values given for each unit in the Technical data section. 8

9 OPTIONS AND ACCESSORIES Description of the configurations MP - AM 2 Pumps with Water storage tank 9 7 MP - AM 2 Pumps without Water storage tank 1 1 IN IN 4 6 OUT OUT KT with Water storage tank 9 7 KT without Water storage tank IN OUT IN OUT KT. - Pipe kit, consists of two steel pipes insulated with heat barrier material. Allows the water IN / OUT connections to be routed to the machine. MP. Pumping module. It consists of: 1 On-off ball valves. Turn components such as the water filter, surge chamber and pump on and off when they require routine or supplementary maintenance. 2 Metal gauze water filter. Can be turned on and off and inspected. It is installed on the pump suction side. Prevents any machining residues (dust, swarf, etc.) that may be in the water pipes from entering the pump impeller or plate-type heat exchanger. 3 Hydraulic pump. Circulates water around the system. The pumps have a high head and suit the majority of installation requirements. The pump is safeguarded by a motor protector installed in the chiller s electric panel. 4 Surge chamber. This is a closed, diaphragm type chamber. It absorbs the variations in the volumes of water in the system caused by temperature variations. 5 Water filling.manual function with control positioned on the side of the unit opposite the electric panel and turned on and off by a cock that can be accessed by removing the rear panel. 6 Water pressure gauge. Connected to the water fill pipe. Displays the pressure of the water in the system. 7 Water safety valve. Standard supply. 8 Water outlet. Standard supply. 9 Air vent. Standard supply. 10 Antifreeze heater connection. Standard supply. 11One-way check valves. Only installed if the Pumping Module accessory with 2 pumps is installed (one valve for each pump). NOTE: it is essential to purchase the units with either the KT or MP accessory described previously. The choice of one automatically excludes the other. 9

10 OPTIONS AND ACCESSORIES Electrical accessories CR - Remote Control. This device consists of a remote control which allows all the control and monitoring functions of the control unit on the machine to be controlled up to 100 meters away from the actual machine itself. It has been specially designed for installation on a wall inside the building. Use a threepole. The transmission line must be routed in a dedicated duct, separate from any electric powering lines (230/400 V). It has four keys used to select the controls on the controller installed on the machine, the only difference being that the scroll-up and scroll-down functions have been separated from the mode and on-off keys in order to make the control easier to use. During normal operation, the operating temperature (or the temperature read by the probe on the exchanger inlet) in degrees centigrade appears on the LCD display or the alarm code, if at least one is activated. The temperatures read by the other probes can be read by means of a few simple operations. If faults occur during normal operation, the controller stops the machine and displays the code of the alarm in question. After the alarm has been checked and its cause eliminated, the controller can be reset by pressing the on/off key. The remote control has the following keys: The controller has five LEDs on the left-hand side of the interface, that display the status functions of the machine: LED of compressors 1 and 2 (circuit 1). LED of compressors 3 and 4 (circuit 2). Electric antifreeze heater LED. HEATING mode LED COOLING mode LED MODE KEY Selects the operating mode (waiting for start-up or operation) of the machine. ON-OFF KEY Allows the controller to be turned on and off and resets the alarms. MODE plus ON/OFF KEYS If pressed at the same time, are used to access and quit the various menu levels. UP KEY When the menu is displayed, is used to scroll forwards through the items in the menu itself, or to increase the value of a parameter. DOWN KEY When the menu is displayed, is used to scroll backwards through the items in the menu itself, or to decrease the value of a parameter. OP - Programmer Clock. Allows the unit to be turned on and off, depending on the selected time settings (up to 14 settings can be entered, divided as required throughout the 7 days of the week). RAG (F) Electric antifreeze heating element on the storage tank. Plug type. It activates in parallel with the evaporator s antifreeze heating element and keeps the water at a temperature able to prevent ice from forming during the winter, when the unit is not used. TAT - High temperature thermostat. Consists of two contact thermostats installed on the delivery pipe of the refrigerating compressors. They block the compressor if they detect a delivery temperature that exceeds a fixed value (that cannot be modified). Mechanical options Special finned heat exchangers Coils with copper fins Coils with tin-coated copper fins Coils with aluminium fins with acrylic coating Electrical options Power source voltage rating 230V-3-50Hz 10

11 OPTIONS AND ACCESSORIES Combinations of accessories-models Mechanical Accessories Electrical Acces. MODEL ACCESSORY CODE Spring vibration dampers Modulo di Pompaggio AVM 10 (F)(1)(4) AVM 11 (F)(1)(4) AVM 12 (F)(2)(4) AVM 13 (F)(2)(4) AVM 24 (F)(5) AVM 25 (F)(5) AVM 26 (F)(5) AVM 27 (F)(5) See tables below for models GM 1 (M) Pressure gauge unit GM 4 (M) GP7 (M) Protective grilles GP21 (M) SAA 13 (M) Water storage tank Standard SAA 14 (M) SAA 18 (M) MP7-AM (M) 1 Pump MP13-AM (M) With storage tank MP51-AM(M)(4) storage on the plant MP4-AM (M) Delivery 2 Pumps MP10-AM (M) MP48-AM(M)(4) MP8-AR (M) 1 Pump MP14-AR (M) With storage tank MP52-AR (M)(4) storage on the plant MP5-AR (M) Return 2 Pumps MP11-AR (M) MP49-AR (M)(4) MP9-PS (M) 1 Pump MP15-PS (M) With storage tank MP53-PS (M)(4) primary and MP6-PS (M) secondary circuit 2 Pumps MP12-PS (M) MP50-PS(M) MP55 (M) (3) 1 Pump MP58 (M) (3) Without storage tank MP60 (M) (3) MP54 (M) (3) 2 Pumps MP59 (M) (3) MP61 (M) (3) KT4 (M) (4) KT5 (M) (4) KT15 (M) (3) Pipe kit KT16 (M) (4) KT17 (M) (3) KT18 (M) (3) High temperature thermostat TAT2 (M) Remote control CR 1 (F) Programmer clock OP (F) Antifreeze heating element for the accumulation tank NOTES: (M): mounted in the factory (F): supplied for installation by customer (1): Basic version MODEL ACCESSORY CODE AVM 24 (F)(4) AVM 25 (F)(4) RAG1 (F) (2): Silenced version (3): Unit supplied without the water storage tank (4): Unit supplied with the water storage tank MATCHABLE UNIT IP 285 VB AB 7M5 IR 285 VB AB 7M5 IR 285 VB AS 7M5 IR 315 VB AB 7M5 IP 315 VB AB 7M5 IP 315 VB AS 7M5 IP 285 VB AS 7M5 IR 315 VB AS 7M5 MODEL ACCESSORY CODE AVM 26 (F)(3) AVM 27 (F)(3) (5): Please refer to tables below for coupling with each accessories: MATCHABLE UNIT IP 285 VB AB 7M5 IR 285 VB AB 7M5 IR 285 VB AS 7M5 IR 315 VB AB 7M5 IR 315 VB AS 7M5 IP 315 VB AB 7M5 IP 285 VB AS 7M5 IP 315 VB AS 7M5 11

12 TECHNICAL SPECIFICATIONS AND STANDARD PERFORMANCES - R407C Technical specifications of unit AB-7M5 Model UM Net cooling capacity (1) kw Net total power input (1) kw Maximum pressure on wet side (NB) 600 / 1000 kpa Gross cooling capacity (1)(E) kw Gross total power input (1)(E) kw Compressor specifications Type SCROLL Quantity 4 N N Throttling steps 4 N Oil charge Circuit 1 (1a+1b) l Circuit 2 (2a+2b) l Power input kw Plate-type heat exchanger specifications Quantity 1 N Water capacity l Water flow rate (1) l/s Water pressure drop (1)(E) kpa Specifications of coils with extended surfaces Number of coils 4 N Total area 11.6 m 2 Fan specifications Number of fans 4 6 N Diameter [ ] 800 mm Maximum speed 900 rpm Total air flow rate (2) l/s Motor rating 1.5 kw Water Storage Tank specifications* Water capacity 700 l * : The water storage tank is an accessory that must be requested when the unit is ordered. Pumping Module accessory specifications Model UM Pump power rating kw Surge chamber volume 24 l Service charge pressure of surge chamber 150 kpa Water flow rate (1) l/s Working head (1)(MP) kpa Electrical specifications (3)(MP) Power supply 400/3+N/50 V/ph/Hz Total maximum power input [ FLA ] A Total maximum power input [ FLI ] kw Total maximum surge current [ MIC] A NOTES: (1): The data refer to: Water temperature: inlet: 12 C - outlet: 7 C. Outdoor air temperature 35 C D.B. (2): At fan s top speed (3):At maximum tolerated operating conditions Noise levels (E) Mod. SWL (db) SPL Octave bands (Hz) Total (dba) db db(a) ,4 95,2 92,8 90,4 87,9 84,9 77,1 67, ,4 95,2 92,8 90,4 87,9 84,9 77,1 67, ,4 96,2 93,8 91,4 88,9 85,9 78,1 68, ,4 97,2 94,8 92,4 89,9 86,9 79,1 69, ,4 97,2 94,8 92,4 89,9 86,9 79,1 69, ,4 98,2 95,8 93,4 90,9 87,9 80,1 70, ,4 99,2 96,8 94,4 91,9 88,9 81,1 71, ,4 99,2 96,8 94,4 91,9 88,9 81,1 71, (E):Data certificated by EUROVENT (MP):For units equipped with Pumping Module accessory MP-AM or MP-AR. (NB):Regarding unit WITH (600 kpa) or WITHOUT (1000 kpa) Storage Tank accessory. SWL = Sound power levels, with reference to 1x10-12 W. The Total sound power level in db(a) measured in compliance with ISO 9614 standards, is certified according to the Eurovent certification program. Eurovent certification (E) exclusively refers to the Total Sound Power in db(a), which is therefore the only binding acoustic specification (the values of the Octave bands in the table are indicative). SPL = Sound pressure levels, with reference to 2x10-5 Pa. The sound pressure levels are values calculated by applying the ISO-3744 relation (Eurovent 8/1) and refer to a distance of 1 meter away from the external surface of units operating in the open field with directivity factor 2 and the units operating in nominal conditions in the cooling mode.

13 TECHNICAL SPECIFICATIONS AND STANDARD PERFORMANCES - R407C Standard performances AB-7M5 MODEL TW OUTDOOR AIR TEMPERATURE ( C D.B.) kwf kwa kwf kwa kwf kwa kwf kwa kwf kwa kwf kwa , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , Tw = Outlet water temperature in C kwf = Net refrigerating power (kw). kwa = Compressor power input (kw). The standard performances refer to a 5 C temperature difference between the water entering and leaving the plate-type heat exchanger and to operation of the unit with all the fans to top speed. A 0.44 x 10-4 m 2 K/W fouling factor has also been considered with the unit installed at zero meters above sea level (Pb = 1013mbar). 13

14 TECHNICAL SPECIFICATIONS AND STANDARD PERFORMANCES - R407C Technical specifications of unit AS-7M5 Model UM Net cooling capacity (1) kw Net total power input (1) kw Maximum pressure on wet side (NB) 600 / 1000 kpa Gross cooling capacity (1)(E) kw Gross total power input (1)(E) kw Compressor specifications Type SCROLL Quantity 4 N N Throttling steps 4 N Oil charge Circuit 1 (1a+1b) l Circuit 2 (2a+2b) l Power input kw Plate-type heat exchanger specifications Quantity 1 N Water capacity l Water flow rate (1) l/s Water pressure drop (E) kpa Specifications of coils with extended surfaces Number of coils 4 N Total area 11.6 m 2 Fan specifications Number of fans 4 6 N Diameter [ ] 800 mm Maximum speed 650 rpm Total air flow rate (2) l/s Motor rating 0.75 kw Water Storage Tank specifications* Water capacity 700 l * : The water storage tank is an accessory that must be requested when the unit is ordered. Pumping Module accessory specifications Model UM Pump power rating kw Surge chamber volume 24 l Service charge pressure of surge chamber 150 kpa Water flow rate (1) l/s Working head MP) kpa Electrical specifications (3)(MP) Power supply 400/3+N/50 V/ph/Hz Total maximum power input [ FLA ] A Total maximum power input [ FLI ] kw Total maximum surge current [ MIC] A NOTES: (1): The data refer to: Water temperature: inlet: 12 C - outlet: 7 C. Outdoor air temperature 35 C D.B. (2): At fan s top speed (3):At maximum tolerated operating conditions Noise levels (E) Mod. SWL (db) SPL Octave bands (Hz) Totale (dba) db db(a) ,4 87,0 84,8 80,3 77,4 73,8 65,3 56, ,4 87,0 84,8 80,3 77,4 73,8 65,3 56, ,4 88,0 85,8 81,3 78,4 74,8 66,3 57, ,4 89,0 86,8 82,3 79,4 75,8 67,3 58, ,4 89,0 86,8 82,3 79,4 75,8 67,3 58, ,4 90,0 87,8 83,3 80,4 76,8 68,3 59, ,4 93,0 90,8 86,3 83,4 79,8 71,3 62, ,40 93,00 90,80 86,30 83,40 79,80 71,30 62, (E):Data certificated by EUROVENT (MP):For units equipped with Pumping Module accessory MP-AM or MP-AR. (NB):Regarding unit WITH (600 kpa) or WITHOUT (1000 kpa) Storage Tank accessory. SWL = Sound power levels, with reference to 1x10-12 W. The Total sound power level in db(a) measured in compliance with ISO 9614 standards, is certified according to the Eurovent certification program. Eurovent certification (E) exclusively refers to the Total Sound Power in db(a), which is therefore the only binding acoustic specification (the values of the Octave bands in the table are indicative). SPL = Sound pressure levels, with reference to 2x10-5 Pa. The sound pressure levels are values calculated by applying the ISO-3744 relation (Eurovent 8/1) and refer to a distance of 1 meter away from the external surface of units operating in the open field with directivity factor 2 and the units operating in nominal conditions in the cooling mode.

15 TECHNICAL SPECIFICATIONS AND STANDARD PERFORMANCES - R407C Standard performances AS-7M5 MODEL OUTDOOR AIR TEMPERATURE ( C D.B.) TW kwf kwa kwf kwa kwf kwa kwf kwa kwf kwa kwf kwa , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , Tw = Outlet water temperature in C kwf = Net refrigerating power (kw). kwa = Compressor power input (kw). The standard performances refer to a 5 C temperature difference between the water entering and leaving the plate-type heat exchanger and to operation of the unit with all the fans to top speed. A 0.44 x 10-4 m 2 K/W fouling factor has also been considered with the unit installed at zero meters above sea level (Pb = 1013mbar). 15

16 OPERATING RANGE Operating range The graphs below give the operating ranges within which correct operation of the units is guaranteed. The use of the units in conditions differing from those indicated will void the warranty with which the product is supplied. In the following table, there are the thermal water head limit values of the unit. Thermal Water Head Limit value Minimun C 3 Maximus C 8 COOLING MODE 12 [ C] OUTLET WATER TEMPERATURE Water ΔT= 5 C In these applications, it s advisable to use brine. [ C B.S.] OUTDOOR AIR TEMPERATURE 16

17 HOW TO SELECT THE UNIT 1) The Standard Performances tables in the Technical data and standard performances chapter give the useful refrigerating output capacity values with the relative compressor input power values of the individual units in standard conditions, for each unit and for different outdoor air and outlet water temperature values. The data can be interpolated but not extrapolated. 2) The Technical data and standard performances tables in this technical handbook refer to use of R407C refrigerant, as shown by the titles in the reference section and depending on the unit in question. 3) The tables under the Standard Performances values give the operating temperature limits of the outdoor air that may enter the condenser. 4) The power input values in the Standard Performances tables refer to the compressors alone. Consult the Technical data of the unit tables for the power input of the fans at their top rate. 5) The Standard Performances values refer to 5 C of Δt of the water between the inlet and outlet of the evaporator. Use corrective factor F cd in Tab.3 for different values. To ensure the heat exchanger-evaporator operates in the correct way, comply with the limits to use given in the Loss of head and Useful head sections. 6) The Standard performances values are based on a 0.44* x10-4 m 2 C / W fouling factor of the heat exchanger on the wet side. Use correction factor F cp indicated in Tab. 1 for different values. 7) The Standard Performances values refer to a unit installed in places at zero meters above sea level (Pb = 1013 mbar). Use Performances correction factor F ch indicated in Tab. 2 for operation at different altitudes. 8) Consult the Loss of head section to determine the loss of head on the wet side through the unit. If the units are equipped with the Pumping Module accessory with storage on the water supply plant delivery, or storage pre-engineered for the primary or secondary circuit, the useful head of the unit can be determined by means of the diagram in the Useful head section. Remember that the curves refer to the useful head calculated as difference between the pump head and the loss of head of the components (filter, on-off devices, pipes, tank, plate type heat exchanger) installed in the hydraulic circuit of the unit. 10)Use the Noise levels tables to check the acoustics. 11)If a unit equipped with one of the Pumping Module accessories is being evaluated, check in the Maximum volume of water section to make sure that the capacity of the surge chamber supplied with the accessory suits the volume of water actually in the system being supplied. Example of how the unit is selected: Selection of a unit able to supply an 160 kw refrigerating power in the following conditions: - Outdoor air temperature = 35 C - Temperature of the cold water outlet by the machine = 6 C - Inlet/outlet temperature difference of the water Δt = 6 C Also consider: - a 0.88x10-4m 2 C/W fouling factor on the wet side of the heat exchanger - unit installed in a place at 300 meters a.s.l. The unit must also guarantee a sound pressure level of less than 68 db(a) measured one meter away from the machine. Solution: In view of the maximum sound level value, the choice will be directed towards soundproofed units of the silenced type. Beginning with the refrigerating power required at the given conditions of use and having checked the Standard Performances table, model IR 180 VB AS7M5 can be selected as it provides a standard refrigerating power of 168 kw and a sound pressure level of 65 db(a) one meter away from the machine. The effective refrigerating power provided by the machine in the real conditions of use will be: Pf = Pfs Fc H Fc Where: P f = refrigerating power provided in the real operating conditions (kw) P f s = refrigerating power provided in standard conditions (kw) F CH = correction factor for the height above sea level F CP = correction factor for the fouling factor F CD = correction factor for the temperature difference The available data and tables 1, 2, 3 can be used to determine the values of correction factors F CH = 0.99,F CP = 0.98 F CD = 1.012, after which the refrigerating power supplied in the real operating conditions can be calculated, i.e.: Pf = (168) (0.99) (0.98) (1.012) =165 kw In the given conditions of use, the selected unit provides a 165 kw refrigerating power, which meets the cooling requirements. The flow rate of the water that passes through the evaporator will be: Pf 165 Q = = = 7.88 c Δt D Fc p l/s 17

18 HOW TO SELECT THE UNIT with c = kj/kg C specific heat of the water. A 38 kpa loss of head is given in the Loss of head graph, on a level with the determined water flow rate of the selected model. This value is acceptable since it is within the limit values given in Limits to use. A 172 kpa useful head is given in the Useful head graph, on a level with the determined water flow rate and the curve of the selected model. With reference to the Maximum water volume section drawing and supposing that the difference in level between the highest point in the circuit and the unit is 20 meters (case B of table 5), the chamber must be given a 226 kpa setting while the maximum amount of water in the system (including the volume of the tank of the pumping module) will be 1732 liters (V max ). If the real volume of water in the system is less than 1732 liters, there will be no need to install an additional surge chamber. On the other hand, if the volume is greater, proceed as described below to size an additional surge chamber: Volume of the system (V i ) = 2000 liters ΔV = V i - V max = 268 liters E C = P i (Surge chamber service charge) = (H / ) x 100 = 226 kpa (326 kpa absolute) P f (Fixed value) = 700 kpa (absolute value) Volume of additional surge chamber = (E x ΔV) / (1 - P i / P f ) = (0.0074)(268)/(1-326/700) = 3.71 Liters An additional surge chamber with a capacity of more than 3.71 liters and a 226 kpa setting must therefore be installed. NOTE: If brine is added to the water, the final checks must be made considering the correction due to the percentage of brine used. The correct value of the additional surge chamber to be installed in the system is found with reference to the Correction factors for the total volume of the system with brine table in the Maximum Volume of Water section. Considering the above example again, supposing that 30% brine is to be used: the corresponding correction value for this percentage of brine used in the cooling mode is 0.652, with reference to the Correction factors for the total volume of the system with brine table. The maximum amount of water in the system with brine added is as follows: V max,g = V max x = 1732 x = 1129 liters ΔV G = Vi - V max,g = =871 liters E G = Thermal expansion E /0.652= /0.652= Thus, the volume of the surge chamber must be: (E G x ΔV G ) / (1-Pi/Pf) = (0,0113 x 871) / (1-326/700)= 18.5 liters An additional surge chamber with a capacity of more than 18.5 liters and a 226 kpa setting must therefore be installed. 18

19 HOW TO SELECT THE UNIT Tab.1 Correction factor F cp Fs (m 2 C/W) Fc - P Clean x x x FS = Fouling factor Fc - P = Refrigerating power correction factor Tab.2 Aslm (m) Sea level Correction factor F ch Pb (mbar) Aslm = Height above sea level Pb = Barometric pressure Fc - H = Refrigerating power correction factor Fc - H Tab.3 Correction factor F cd ΔT ( C) FC- D DT = Thermal gradient Fc - D = Refrigerating power correction factor If the system is not drained during winter, but is stopped and brine is used, it will be necessary to introduce multiplicative correction factors for the Refrigerating Power (F CPG ) and Water Flow Rate (F CQG ). Table 4 also gives the reference multiplication factors for the Compressor power input and Loss of head values. Supposing that brine with 30% ethylene glycol is used, the Refrigerating Power, Water Flow Rate and Loss of Head values previously found for the selected unit become: P* f = P f (F CPG ) = (165) (0.97) = 160 kw Q*= Q (F CQG ) = (7.88) (1.12) = 8.83 l/s Loss of Head = (38)(1.25) = 48 kpa Tab.4 % of brine in weight Freezing temperature Refrigerating power multiplier (FCPG) Power input multiplier Water flow rate multiplier (FCQG) Loss of head multiplier % % % %

20 WATER PRESSURE DROP The graph below illustrates the loss of head values in kpa depending on the flow rate in liters/second. The operating range is delimited by the minimum and maximum values given in the next table Water pressure drop (kpa) Water flow rate (l/s) Limits to operation Model UM NOTES Graph reference Q=Water flow rate Lower limit value Q l\s Δp 10 kpa Δp=Loss of head Upper limit value Q l\s Δp 150 kpa Maximum operating pressure on wet side 600 kpa 20

21 WORKING HEAD The graph below illustrates the useful head values (kpa) depending on the flow rate in (liters/second). The operating range is delimited by the minimum and maximum values given in the next table. Useful head is the one at the outlet of the standard pumping module minus all the loss of head values of the unit Working head (kpa) ,0 6,0 8,0 10,0 12,0 14,0 16,0 18,0 20,0 22,0 24,0 Water flow rate (l/s) Limits to operation Model UM NOTES Graph reference Q=Water flow rate Upper limit value Q l\s 21

22 MAXIMUM VOLUME OF WATER Maximum volume of water in the system with wet module Before filling the water system, it is advisable to consider the type of installation in question, i.e. check the difference in level between the wet module and user. The following table gives the maximum water content of the water supply system in liters, depending on the capacity of the standard surge chamber supplied and the pressure at which it should be charged. The surge chamber setting must be regulated to suit the maximum positive difference in level of the user. Maximum setting value 600 kpa. With a positive H of more than meters, calculate the surge chamber s service charge value in kpa using the formula below: Surge chamber service charge= [H/ ] x100 = [kpa] NOTE. In case A, make sure that the user s lowest point is able to withstand the global pressure. Tab.1 Model Surge chamber volume (liters) 24 Thermal expansion of water (10-40 C) H (metri) Surge chamber pressure (kpa) Maximum total volume of water supply system (liters) Case A H <0 150 (standard) < H < (standard) Case B NOTE: If the unit operates with brine, calculate the real volume of the system by taking into account the corrective factors for the volume of the system given in the table below. Corrective factors per total maximum volume of the system with brine % of brine 0% 10% 20% 30% 40% Cooling Mode Heating Mode CASE B U CASE A U U= User 22

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,

More information

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years

More information

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017 Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air

More information

O L R E RGA ST RA N AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION TECHNICAL MANUAL

O L R E RGA ST RA N AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION TECHNICAL MANUAL -FRIEND A R E IG RA N T G RGA ST RE F S Y E O L C AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION TECHNICAL MANUAL 1 2 SUMMARY THIS MANUAL IS DIVIDED INTO SECTIONS. THEIR NAMES APPEAR IN THE

More information

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING

More information

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS RAE 1352 F.K + MV AIR R-407C FC Series RAE... F.K Cooling capacity from 77 to 289 kw - 2 circuits The air cooled chillers of RAE... F.K series, are designed for outdoor installation and are particularly

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98 Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw Scroll Compressors Series: SCAEY-FC Leaflet: DE 98 Issue: 04/11 Supersedes: 12/10 Identification code Index Index... pag. 2 Identification code...»

More information

RTA TECHNICAL MANUAL AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L S E A F RA N

RTA TECHNICAL MANUAL AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L S E A F RA N A RE F S E -FRIEND Y R E IG RA N T G AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L RTA C TECHNICAL MANUAL 1 2 SUMMARY THIS MANUAL IS DIVIDED INTO SECTIONS. THEIR NAMES APPEAR IN THE HEADING

More information

RMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

RMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL RMA ECO-FRIENDLY REFRIGERANT GAS AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the

More information

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1 UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A

More information

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98 Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw Scroll Compressors Series: SCAEY-FC Leaflet: DE 98 Issue: 01/16 Supersedes: 12/13 Identification code Index Index... pag. 2 Identification code...»

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are

More information

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES COOLING CAPACITY FROM 76 TO 612 Kw 1 AND 2 COOLING CIRCUITS RAE 1702 F Kc + P2 28 Above picture is only indicative

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are

More information

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual u Air-to-Water Reverse Cycle Heat Pumps AQH 40 to 130 40 to 131 kw 45 to 141 kw Engineering Data Manual EDM AQH-W.3GB Date : November 2007 Supersedes : TM AQH-W.2GB/03.04 Specifications The Aqu@Logic air-to-water

More information

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10 Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW Compressors Scroll Serie: Series: Emissione: Issue: SCAEY Catalogo: Leaflet: Sostituisce: Supersedes: DE 88 04/11 12/10 Index

More information

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB R407C EASY_R Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans 5,2 41,5 kw T_ESY_R_0508_GB EASY_R R407C INDEX WORKING LIMITS... 3 SERIES IDENTIFICATION... 4 MODEL

More information

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER

More information

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 46 Above picture is only indicative and is not binding AIR FC The packaged air cooled chillers of RAS Kp series are suitable

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

TCHE-THHE TCEE

TCHE-THHE TCEE K11208-GB ed. 3 TCHE-THHE TCEE Q-Flow range Macrosystem 148,4 262,2 kw TCHE-THHE - Water cooled water chillers and heat pumps units with environmentally friendly refrigerant. Range with hermetic Scroll

More information

kw COOLING kw HEATING

kw COOLING kw HEATING Heat pump water/water liquid chillers for indoor installation. Inversion on hydraulic circuit. 394 1505 kw COOLING 477 1976 kw HEATING technicalcatalogue T_FRGSCRWP_0913_GB INDEX GENERAL CHARACTERISTICS...

More information

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.

More information

TCHE-THHE TCEE

TCHE-THHE TCEE K11206-GB ed. 6 TCHE-THHE 155 2130 TCEE 155 2130 Q-Flow range Macrosystem 50,2 124,5 kw TCHE-THHE - Water cooled water chillers and heat pumps units with environmentally friendly refrigerant. Range with

More information

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Quality Management Systems 0RB 008-05 Nominal cooling capacity 8- The new generation of Aquasnap liquid chillers was designed

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5

More information

kw. technicalcatalogue

kw. technicalcatalogue Packaged air cooled liquid chillers in A class energy efficiency for outdoor installation equipped with scroll compressor and microchannel condensing coils 108 876 kw technicalcatalogue T_PYXCLA_0413_GB

More information

44,9 202,0 kw. technicalcatalogue

44,9 202,0 kw. technicalcatalogue Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressor and microchannel condensing coils 44,9 202,0 kw technicalcatalogue T_PYXU_0413_GB INDEX EUROVENT CERTIFICATION...

More information

Air-to-water scroll chillers

Air-to-water scroll chillers Air-to-water scroll chillers Model CGA 040 to 115 Cooling capacity: 14-40 kw CG-PRC031B-GB Table of Contents Technical specifications...4 Standard configuration... 4 Hydraulic version... 4 Casing... 4

More information

Water chillers water/water type SIGMA Technical information manual

Water chillers water/water type SIGMA Technical information manual Water chillers water/water type SIGMA Technical information manual 2 INDEX Technical features 1 Versions 3 Accessory versions 4 Technical data 7 Electrical data 11 Cooling capacity 12 Heating capacity

More information

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line) ERAH MC Ka AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line) Range 394-1220 kw Liquid chillers air condensing unit Package external installation Screw compressors

More information

RFA TECHNICAL MANUAL SINGLE PACKAGED ROOFTOP UNITS ROOF-TOP. Mod

RFA TECHNICAL MANUAL SINGLE PACKAGED ROOFTOP UNITS ROOF-TOP. Mod RFA SINGLE PACKAGED ROOFTOP UNITS ROOF-TOP 34.4 9.8 kw in cooling mode 38.6 117.8 kw in heating mode DOZONE SAVE Mod. 35.1 45.1 55.1 70.2 90.2 1.2 TECHNICAL MANUAL TABLE OF CONTENTS GENERAL FEATURES................................................................................

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB Packaged air cooled liquid chillers for outdoor installation 42 574 kw technicalcatalogue T_EGL_1012_GB INDEX EUROVENT CERTIFICATION... 3 GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION...

More information

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB Next P 6 112 kw COOLING 5 93 kw HEATING Heat pump air conditioners with upflow air delivery technicalcatalogue T_NXTP_0411_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 4 MODEL IDENTIFICATION...

More information

Kälte Klima. Water cooled water chillers Not Reversible heat pumps from 18 kw to 75 kw. Series:

Kälte Klima. Water cooled water chillers Not Reversible heat pumps from 18 kw to 75 kw. Series: Water cooled water chillers Not eversible heat pumps from 18 kw to 75 kw Series: Issue: MCW N Leaflet: DE 59 03/13 Supersedes: --- Identification code Index MCWY 15/1 N PAC 1 2 3 4 5 6 7 8 1 M mini series

More information

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient PRODUCT SELECTION DATA Easy and fast installation Compact, reliable and efficient Class A variable speed circulator available Air-Cooled Liquid Chillers 0RB 008-015 CARRIER participates in the ECP programme

More information

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW TECHNICAL CATALOGUE EQSL Air Cooled Water Chillers Models: 300 V2 F06 1310 V2 F16 Cooling capacity: 299 to 1310 KW 02.16 ref. 207598 Rev.100 Thank you for trusting in Hitecsa Products. Our company has

More information

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with

More information

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES Air to water chillers and heat pumps The water chillers range is an efficient and low-noise product designed for medium to big applications. The water chillers are suitable for water outlet temperatures

More information

unico pf unico pf rcgroupairconditioning

unico pf unico pf rcgroupairconditioning : ckaged air cooled liquid chillers for indoor installation, equipped with scroll compressors and plug fan Cooling Capacity: 19,6 264 unico pf PLTE rcgroupairconditioning R410 E C MIN FETURES ir cooled

More information

ELFOENERGY LARGE 2 TECHNICAL BULLETIN HIGH EFFICIENCY AIR-COOLED LIQUID CHILLER FOR OUTDOOR INSTALLATION WSAT-XEE SERIES

ELFOENERGY LARGE 2 TECHNICAL BULLETIN HIGH EFFICIENCY AIR-COOLED LIQUID CHILLER FOR OUTDOOR INSTALLATION WSAT-XEE SERIES TECHNICAL BULLETIN ELFOENERGY LARGE HIGH EFFICIENCY AIR-COOLED LIQUID CHILLER FOR OUTDOOR INSTALLATION WSAT-XEE SERIES Nominal cooling capacity from to kw ELFOEnergy LARGE is a highly energy efficient

More information

PYXIS U PYXIS U. rcgroupairconditioning

PYXIS U PYXIS U. rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 44 284 rcgroupairconditioning MIN FETURES

More information

CRIMSON & CRIMSON MAX

CRIMSON & CRIMSON MAX High efficiency water/water and geothermal heat pumps 5 114 General High efficiency water/water and geothermal heat pumps. Ideal for heating, cooling and production of domestic hotwater with total or partial

More information

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP EVH R-407C WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP Size Cooling Heating [kw] [kw] 7 2.0 1.9 11 2.6 2.5 15 3.9 3.3 5.2 5.5 25 7.3 6.7 31 8.9 8.4 41 10.7 9.8 REPLACE: BT02E009GB-01 The Versatemp

More information

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps. Air/water cooled chillers and heat pumps 41 303 kw General BETA ECHOS is a range of chillers and ductable air-water heat pumps. Configurations HP: Reversible heat pump LE: For connection to remote evaporator

More information

ELFOEnergy Duct Inverter

ELFOEnergy Duct Inverter Technical Bulletin BT14E002GB-02(EC1) ELFOEnergy Duct Inverter Air-water ductable liquid chiller for indoor or outdoor installation SERIES WSA-XIN 21-141 Nominal cooling capacity (A35/W7) da 4 a 31 kw

More information

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES Air to water chillers and heat pumps The water chillers range have been designed for small and medium residential and commercial applications. The water chillers are suitable for water outlet temperatures

More information

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning : Packaged air cooled liquid chillers with free-cooling system for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 314 1343 Free-Cooling Capacity: 308 938 GLYCOL

More information

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER

More information

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Большая библиотека технической документации   каталоги, инструкции, сервисные мануалы, схемы. Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive,

More information

Air cooled chillers and heat pumps

Air cooled chillers and heat pumps 101 B 05/07 A Date: July 2005 Supersedes: none Air cooled chillers and heat pumps McSmart 160 500 from 48 to 155 kw McQuay is participating in the Eurovent Certification Programme. Product are as listed

More information

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

HYDROCIAT LW R407C. Water cooled chillers USE RANGE Screw compressors CIAT dry direct expansion shell and tubes evaporator HPS equipment (High Power System) cooling or heating Heat recovery ENVIRONMENTALLY HFC R407C PROTECTION DE FRIENDLY L'ENVIRONNEMENT

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

PURESTREAM CHILL-CUBE TM BY FRIULAIR

PURESTREAM CHILL-CUBE TM BY FRIULAIR PURESTREAM CHILL-CUBE TM BY FRIULAIR Air-cooled water chiller Cooling capacity from 0.5 to 6 tons R407C Refrigerant QPS Inspection label certified to CSA standards 2 Year parts warranty The QBE Chill-Cube

More information

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata EKS/HE Refrigerant R410A GWP=2.088 Scroll Compressor Shell & Tube exchanger Axial fan Brazed plate heat exchanger MultiScroll Air-cooled liquid chillers High efficiency Solution B - Base I - Integrata

More information

GLIDER EVO GLIDER EVO. rcgroupairconditioning

GLIDER EVO GLIDER EVO. rcgroupairconditioning : Packaged air cooled liquid chillers for outdoor installation equipped with screw compressors and axial fans Cooling Capacity: 300 1313 rcgroupairconditioning R134a SHELL C MIN FETURES ir cooled liquid

More information

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw TECHNICAL INSTRUCTIONS CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw CHG 1 CHG 1 8. kw. kw.7 kw 1. kw April 7 19 - GB - 2 MARKING This product marked conforms to the essential

More information

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW TECHNICAL INSTRUCTIONS PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER to KW PHRT PHRT PHRT PHRT For terminal units and boiler overhaul applications Heating Cooling PHRT.00 kw -. kw PHRT.0 kw /.0 kw

More information

Ultimate energy saving technology

Ultimate energy saving technology Ultimate energy saving technology CWT Chiller Series CWt purestream series water chillers The new CWT Purestream chiller range is specifically designed to meet the stringent cooling requirements of today

More information

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw Air cooled chillers with brushless oil-free compressors R-134a RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw External installation with very low sound level Cooling circuit with

More information

ULTIMATE ENERGY SAVING TECHNOLOGY

ULTIMATE ENERGY SAVING TECHNOLOGY ULTIMATE ENERGY SAVING TECHNOLOGY CWM CHILLER SERIES CWM PURESTREAM SERIES WATER CHILLERS The new CWM Purestream chiller range is specifically designed to meet the stringent cooling requirements of today

More information

pyxis pyxisa NEW rcgroupairconditioning

pyxis pyxisa NEW rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 119,0 808,0 PLTE C rcgroupairconditioning

More information

TCHVZ TCEVZ

TCHVZ TCEVZ K20310EN ed. 3 TCHVZ 1200 31630 TCEVZ 1200 31630 Serie Z-Flow Macrosystem 171,9 1.629,2 kw TCHVZ - Water cooled water chillers with R134a ecological refrigerant. Semi-hermetic screw compressor range. TCEVZ

More information

pyxis u pyxis ua NEW rcgroupairconditioning

pyxis u pyxis ua NEW rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 44,9 200,0 rcgroupairconditioning R410 C PLTE

More information

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning : Direct expansion close control air conditioners with up-flow or down-flow air delivery. Cooling Capacity: 7 102 NEW SOFTWARE R410A rcgroupairconditioning E C A C UP FLOW DOWN FLOW MAIN FEATURES Precision

More information

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw COOLROW Close control air conditioners for In-Row installation Cooling Capacity: 14 61 Available in versions equipped with: - BLDC inverter scroll compressor on board of the unit - Chilled water feeding

More information

GLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning

GLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning GLIDER EVO CL GLIDER EVO CL: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 282 1513 HIGHEFFICIENCY

More information

Product Catalogue CG-PRC002E-EN. CGAD Liquid Chillers Air-Cooled Scroll Compressor 20 to 150 Tons. July Models: 50 / 60 Hz

Product Catalogue CG-PRC002E-EN. CGAD Liquid Chillers Air-Cooled Scroll Compressor 20 to 150 Tons. July Models: 50 / 60 Hz Product Catalogue CGAD Liquid Chillers Air-Cooled Scroll Compressor 20 to Tons Models: 50 / 60 Hz CGAD CGAD CGAD CGAD CGAD CGAD CGAD CGAD CGAD CGAD CGAD CGAD July 2012 CG-PRC002E-EN Introduction IMPORTANT:

More information

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw. 1 Компрессорно-конденсаторные агрегаты Chiller AQH DCI 20 to 30 Air Cooled Water Inverter Heat ump Engineering Data Manual 20 to 30 kw 20 to 30 kw Specifications 3 AQH DCI Finned coil optimized in ing

More information

Kälte Klima. Water cooled water chillers from 200 kw to 1550 kw. Screw Compressor LCWX DE 56 01/16 12/13

Kälte Klima. Water cooled water chillers from 200 kw to 1550 kw. Screw Compressor LCWX DE 56 01/16 12/13 Water cooled water chillers from 200 kw to 1550 kw Screw Compressor Serie: Series: Emissione: Issue: LCWX Catalogo: Leaflet: Sostituisce: Supersedes: DE 56 01/16 12/13 Index Identification code Index...

More information

21,8 222 kw COOLING 25,2 236 kw HEATING

21,8 222 kw COOLING 25,2 236 kw HEATING Air cooled multifunction chillers 21,8 222 kw COOLING 25,2 236 kw HEATING technicalcatalogue T_MLTPF_0413_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 WORKING

More information

EQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM

EQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM TECHNICAL CATALOGUE EQEF Water Chillers with Free Cooling System Models:60.1 60.2 70.1 70.2 90.1 90.2 120.1 120.2 135.1 150.1 190.2 200.1 200.2 240.2 270.2 300.2 Cooling capacities: 69,7 to 331 KW 02.16

More information

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories > HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION Available range Unit type IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS Versions (heat recovery) VB Base

More information

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw Multi-pipe Units with Scroll Compressors Model CMAA Cooling capacity 45-485 kw Heating capacity 50-670 kw CMAA multi-pipe units Simultaneous heating and cooling with one product Standard versions Acoustic

More information

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning Industrial PYXIS CL: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with scroll compressor and microchannel condensing coils Cooling Capacity: 108 876

More information

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE

More information

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: N

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: N Packaged air conditioning unit condensed by air model RTC 07L to 30L Ref.: N-27656 0608 Technical information Johnson Controls Manufacturing España, S.L. is participating in the EUROVENT Certification

More information

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the

More information

Compact Horizontal Air-Air Heat Pump Model RTH 07L to 30L. Technical information. Ref.: N

Compact Horizontal Air-Air Heat Pump Model RTH 07L to 30L. Technical information. Ref.: N Compact Horizontal Air-Air Heat Pump Model RTH 07L to 30L Ref.: N-27661 0608 Technical information Johnson Controls Manufacturing España, S.L. is participating in the EUROVENT Certification Program. Products

More information

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet Attractive design, Compact and quiet Many customisable configurations possible For indoor installation New reliable technologies Version with Plug and Cool hydraulic module Cooling capacity: 23 to 140

More information

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw PROCESS CHILLERS AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com PROCESS CHILLERS MAXIMUM EFFICIENCY IN EVERY TYPE OF PROCESS APPLICATION Air cooled liquid chiller for outdoor

More information

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated. NOMENCLATURE INTRODUCTION The HTT HWDX water-cooled chillers range is the latest addition to HTT s growing family of commercial products, featuring the most current technologies advances. The HWDX main

More information

TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE

TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE GB TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE 5 kw - 213 kw TABLE OF CONTENTS 1 The series...4 2 Constructive features...4 3 Layout of components...5 4 Models and configurations...13 5 Technical

More information

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or

More information

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES LS ir cooled water chillers with axial fans + LS The LS water chiller range has been designed for small and medium residential and commercial applications. They are suitable for generating chilled water

More information

PACKAGED AIR COOLED Product Data Catalog

PACKAGED AIR COOLED Product Data Catalog PACKAGED AIR COOLED Product Data Catalog MODELS ASP-10A ASP-15A ASP-20A ASP-00P ASP-00F ASP-00G A MEMBER OF MARDUK HOLDING COMPANY, LLC The Leader in Modular Chillers ETL and CSA Approved CHILLER MODULES

More information

kw. technicalcatalogue

kw. technicalcatalogue Packaged air cooled liquid chillers for outdoor installation equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded evaporator and microchannel condensing coils. 280

More information

E U R O V E N T CERTIFIED PERFORMANCE

E U R O V E N T CERTIFIED PERFORMANCE Compact Horizontal Air-Air Heat Pump Model RTH-7K to 3K Ref.: Y-R719 7 Technical information E U R O V E N T CERTIFIED PERFORMANCE I S O 9 1 ER-8/1991 Clima Roca York S.L. is participating in the EUROVENT

More information

Blue Box Epsilon Echos +

Blue Box Epsilon Echos + Blue Box Epsilon Echos + 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Packaged version in 5 sizes Nominal cooling capacity (A35;W7): 6 26 kw Nominal heating

More information

Contents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79

Contents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79 MCAC-TSM-2008-02 Contents Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79 Contents i MCAC-TSM-2008-02 Introduction Introduction Midea Mini Unitary

More information

BRH. Climaveneta Technical Bulletin. Water-cooled liquid chillers ,5-35,1 kw. Versatile High efficiency Maximum silent-running

BRH. Climaveneta Technical Bulletin. Water-cooled liquid chillers ,5-35,1 kw. Versatile High efficiency Maximum silent-running Climaveneta Technical Bulletin BRH_0011_0121_201211_EN BRH r HFC R-410A 0011-0121 5,5-35,1 kw Water-cooled liquid chillers (The photo of the unit is indicative and may change depending on the model) Versatile

More information