On Balance: Heat Rejection Control a Packaged Solution

Size: px
Start display at page:

Download "On Balance: Heat Rejection Control a Packaged Solution"

Transcription

1 On Balance: Heat Rejection Control a Packaged Solution Echelon Americas Channel Partner Conference March 11, 2005 Presented by Doug Scott VaCom Technologies La Verne, California

2 Opportunity An integrated packaged control with: Broad applicability Value to end users Value to integrators Open systems benefits 2

3 Description One-box integration of: Variable speed drives Bypass controls Controller User interface Energy efficiency Communications 3

4 Application Any type of heat rejection to ambient: Air-cooled condensers Evaporative-cooled condensers Fluid coolers (evap or air-cooled) Cooling towers 4

5 Value to Owners Lower installed cost Lower operating costs Reliability Serviceability Easier life-cycle cost maintenance 5

6 Value to Integrators Higher delivered value to owner Differentiation with life cycle cost Save cost and time vs. custom build New business Retrofit previous projects First opportunity for new customers Leverage utility incentives 6

7 Add to Open Systems Value Subsystem control example: Integrate subsystem elements Built-in energy efficiency optimization Push intelligence closer to end-use Information = service opportunity Manufacturers monitor during warranty Third party service and monitoring Flexibility: integrate now or later 7

8 Energy Background Concepts Vapor compression cycle Lift and floating head pressure Variable speed affinity laws System balance 8

9 Vapor Compression Cycle BASIC CONCEPTS Energy is conserved -- energy in equals energy out. High-pressure Liquid Condenser High-pressure Low-pressure Vapor Vapor Compressor Compressor pumps vapor; refrigerant has the cooling effect: Lb/Hr X BTU/Lb= BTU/Hr Expansion Valve Low-pressure Liquid Evaporator Lowpressure Vapor Compressor Power Heat source (Cooling) 9

10 Cooling System Lift Fixed Floating 10 Evaporator / Condensing Temp Low Temperature Fixed Head Low Temperature Floating Head Medium Temp Fixed Head Medium Temp Floating Head

11 Fixed vs. Floating Head Pressure Temperature, F Jan Feb Mar Apr May Jun Jly Aug Sep Oct Nov Dec Ambient Fixed Setpoint Floating Setpoint 11

12 Variable Setpoint Control Ambient Temperature Condensing Temperature Setpoint

13 Floating Head Pressure Impact on capacity Condensing Temperature, F Capacity, Tons 13

14 Floating Head Pressure Impact on capacity and power Condensing Temperature, F Capacity, Tons Power, kw 14

15 Floating Head Pressure Net effect on efficiency Condensing Temperature, F Efficiency, kw/ton 15

16 Variable Speed Fan Control Third power relationship 100% Capacity varies directly with change in airflow Fan power varies with cube of change in airflow Fan Power % 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 80% speed = 51% power 50% speed = 12% power 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Fan Speed % 16

17 Part Load Performance Variable speed vs. fan cycling On On Off Off 50% capacity 50% power 80 BTUH/Watt 50% 50% 50% 50% 50% capacity 12% power 330 BTUH/Watt Specific efficiency increased by 300% with variable speed 17

18 Energy Savings Energy Savings come from: Lower head pressure Lower fan power Variable speed Variable setpoint System stability Overall: optimum system balance 18

19 Early Experience Successful supermarket trial Vons Controls Retrofit -- Four Store Summary Average kwh Monthly kwh, Thousands kwh Cumulative Savings Savings Target Jan Feb Mar Apr May Jun Jly Aug Sep Oct Nov Dec 19

20 Case Study Cold storage warehouse in Stockton Evaporative condenser Base case = fixed SCT at 85 F Options Float SCT using fixed setpoint Add variable setpoint Add variable speed with fixed setpoint Add variable speed with variable setpoint 20

21 Results Base Annual Energy, mwh Compressor Condenser Control Options FHP FSP VSP VFD Savings Payback NPV Option 1 X X $ 6, $ 63,500 21

22 Results Base Annual Energy, mwh Compressor Condenser Control Options FHP FSP VSP VFD Savings Payback NPV Option 1 X X $ 6, $ 63,500 Option 2 X X $ 8, $ 80,300 22

23 Results Base Annual Energy, mwh Compressor Condenser Control Options FHP FSP VSP VFD Savings Payback NPV Option 1 X X $ 6, $ 63,500 Option 2 X X $ 8, $ 80,300 Option 3 X X X $ 9, $ 52,900 23

24 Results Base Annual Energy, mwh Compressor Condenser Control Options FHP FSP VSP VFD Savings Payback NPV Option 1 X X $ 6, $ 63,500 Option 2 X X $ 8, $ 80,300 Option 3 X X X $ 9, $ 52,900 Option 4 X X X $ 21, $ 175,300 24

25 Example System 75 Ton condenser for two glycol chillers with four separate high sides Estimated first cost savings: $3,000 savings in reduced custom programming $2,500 savings in reduced onsite electrical installation cost and MCC hardware 25

26 Typical Panel 26

27 Controller I/O Analog inputs Ambient DBT Ambient RH Discharge pressures Digital inputs Fan enables VFD status Override status Pump proof Defrost monitor Digital outputs VFD enable VFD auto bypass Pump enable Emergency spray Analog outputs VFD speed 27

28 Controller Functions Capability Up to four separate pressures or temperature inputs Two VFDs per controller VFD control Auto, bypass and service modes Automatic restarts Automatic bypass Control logic Fixed setpoint Variable setpoint using DBT or WBT PID control SCT calculation for different refrigerants Other features Emergency spray control Run time and cycle monitoring 28

29 Communications Interface i.lon100 used for: Initial setup Current status Setpoints Alarms and datalogging Use web browser for setup, setpoint adjustments and current status 29

30

31

32

33

34

35

36

37 Performance Monitoring using EnergyDashboard Remote efficiency monitoring Real time, continuous performance analysis Web based results presentation High level performance metrics Energy efficiency: kw/ton, $/Ton-Hr Maintenance indicators Trends (e.g. refrig. level, inventory) 37

38

39

40

41

42 Questions? Doug Scott VaCom Technologies (909)

Engineers and Contractors - Innovative Technologies to Achieve Highest GeoExchange System Efficiencies for Commercial Projects

Engineers and Contractors - Innovative Technologies to Achieve Highest GeoExchange System Efficiencies for Commercial Projects Engineers and Contractors - Innovative Technologies to Achieve Highest GeoExchange System Efficiencies for Commercial Projects Presented by: Warren (Trey) Austin, PE, CEM, CGD, LEED-AP Geo-Energy Services,

More information

Free cooling on RTAF Chiller. Integrated option

Free cooling on RTAF Chiller. Integrated option Free cooling on RTAF Chiller Integrated option Water based free cooling principle. Use full aluminum (car radiator based) flat channel dry cooler exchangers. Modulate 3 way to reach required free cooling

More information

Auburn University Basketball Arena:

Auburn University Basketball Arena: Auburn University Basketball Arena: How Building Data Analytics Achieved Energy and O&M Savings While Improving Comfort and Sustainability Eric Moore, PE, CEM, Auburn University Hadas Webb, CEM, Cimetrics

More information

Continuous Commissioning: A Valuable Partner to Retrofit Projects

Continuous Commissioning: A Valuable Partner to Retrofit Projects Continuous Commissioning: A Valuable Partner to Retrofit Projects Yeqiao Zhu Aamer Athar Kenneth Banks Ph.D. PE, CEM PE, CEM Energy Systems Laboratory Sempra Energy Solutions Sempra Energy Solutions Charles

More information

Dehumidification: Energy Efficiency Comparisons

Dehumidification: Energy Efficiency Comparisons Fourth Annual Energy Management Workshop Cocoa, Florida February 10-11, 2003 Dehumidification: Energy Efficiency Comparisons Michael K. West, Ph.D., P.E. Building Systems Scientist Advantek Consulting,

More information

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to 1.99 kw Centrifugal compressor with magnetic levitation This is a miniaturized, highly innovative

More information

5. ASSESSMENT RECOMMENDATIONS

5. ASSESSMENT RECOMMENDATIONS 5. ASSESSMENT RECOMMENDATIONS AR No. 1 Reduce Discharge Pressure Recommended Action Reduce the minimum condensing temperatures on your warehouse refrigeration systems from 110 F to 60 F. In order to reduce

More information

WHITE PAPER. ANSI/AHRI Standard for Fan and Coil Evaporators - Benefits and Costs

WHITE PAPER. ANSI/AHRI Standard for Fan and Coil Evaporators - Benefits and Costs Abstract Fan and coil evaporators as used in the industrial refrigeration industry can be certified for performance per ANSI/AHRI Standard 420-2008, Performance Rating of Forced-Circulation Free-Delivery

More information

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and equipment. B. See Division 23 Section

More information

Farm Energy Audit Workshop

Farm Energy Audit Workshop Farm Energy Audit Workshop Sponsored by the Western Mountains Alliance, a member of the Maine Rural Partners Farm Energy Partners Network and Efficiency Maine Skowhegan, Maine May 14, 2008 Walk-Through

More information

Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment.

Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment. Small Commercial Business Energy Audits Recognizing and addressing the special requirements of the small business market segment. Class 7 Class 7: Refrigeration Fundamentals The Vapor-compression cycle

More information

Special Topics on Residential HVAC

Special Topics on Residential HVAC Special Topics on Residential HVAC by Armin Rudd USDOE Building America Program for EEBA Conference 2002 Phoenix, Arizona 10 October 2002 Page 1 of 25 Two Main Topics: 1. Cyclical trade-offs between building

More information

announcements 4/10/08

announcements 4/10/08 Psychrometrics & Design Strategies ARCH 331/431 Spring 2008 Lecture 4 announcements 4/10/08 course website: http://courses.washington.edu/arch3431/index.shtml Course materials (readings, assignments, lectures,

More information

Emerging Technologies: VFDs for Condensers. Douglas T. Reindl Director, IRC University of Wisconsin-Madison. University of Wisconsin-Madison

Emerging Technologies: VFDs for Condensers. Douglas T. Reindl Director, IRC University of Wisconsin-Madison. University of Wisconsin-Madison Emerging Technologies: VFDs for Condensers Douglas T. Reindl Director, IRC University of Wisconsin-Madison University of Wisconsin-Madison 1 We ve looked at VFDs on Evaporators and compressors, what is

More information

CTI Sponsored Educational Program

CTI Sponsored Educational Program Presented By: Kent Martens SPX Cooling Technologies, Inc. Slide No.: 1 CTI Mission Statement To advocate and promote the use of environmentally responsible Evaporative Heat Transfer Systems (EHTS) for

More information

Owner Municipality Built in 1978 Rebuilt in 2001 Rink and bleachers. Surface area (footprint) 4,140 m 2 (44,700 ft 2 )

Owner Municipality Built in 1978 Rebuilt in 2001 Rink and bleachers. Surface area (footprint) 4,140 m 2 (44,700 ft 2 ) Project profile Refrigeration Technological Innovation RAPB REFRIGERATION ACTION PROGRAM For BUILDINGS Colisée des Bois-Francs Victoriaville (Québec) MAJOR RETROFIT Summary Potential for substantial heat

More information

Heat Transfer Products. Product Line Update

Heat Transfer Products. Product Line Update Heat Transfer Products Product Line Update EP2 Portable Chiller Variable-Speed Compressor Option What s different with variable-speed option? Fixed-Speed Compressor Units Variable-Speed Compressor Units

More information

Matt Cooper, PE, BEMP, HBDP, Group 14 Engineering Ken Urbanek, PE, HBDP MKK Consulting Engineers, Inc.

Matt Cooper, PE, BEMP, HBDP, Group 14 Engineering Ken Urbanek, PE, HBDP MKK Consulting Engineers, Inc. M&V Real Results of High Performance Design Matt Cooper, PE, BEMP, HBDP, Group 14 Engineering Ken Urbanek, PE, HBDP MKK Consulting Engineers, Inc. Overview Measurement & Verification (M&V) Plan for New

More information

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and other equipment. B. See Division 23 Section

More information

TrilliumSeries. Condenser

TrilliumSeries. Condenser TrilliumSeries Condenser TrilliumSeries Condenser The TrilliumSeries Condenser uses a patented Dry-Coil Adiabatic Design that saves energy, reduces refrigerant change, and lowers operating costs. The TrilliumSeries

More information

Session: HVAC 101 HVAC 101. Steve Sain Sain Engineering Associates, Inc. August 9, Rhode Island Convention Center Providence, Rhode Island

Session: HVAC 101 HVAC 101. Steve Sain Sain Engineering Associates, Inc. August 9, Rhode Island Convention Center Providence, Rhode Island Session: HVAC 101 HVAC 101 Steve Sain Sain Engineering Associates, Inc. August 9, 2016 Rhode Island Convention Center Providence, Rhode Island Why? 2 Acknowledgements 3 Disclaimer I m gonna shoot down

More information

VARIABLE HEAT RECOVERY IN DOUBLE BUNDLE ELECTRIC CHILLERS. Richard J Liesen 1, Rahul J Chillar 2 1 University of Illinois at Urbana Champaign

VARIABLE HEAT RECOVERY IN DOUBLE BUNDLE ELECTRIC CHILLERS. Richard J Liesen 1, Rahul J Chillar 2 1 University of Illinois at Urbana Champaign VARIABLE HEAT RECOVERY IN DOUBLE BUNDLE ELECTRIC CHILLERS Richard J Liesen 1, Rahul J Chillar 2 1 University of Illinois at Urbana Champaign Dept of Mechanical & Industrial Engineering 1206 WGreen St Urbana,

More information

Air Conditioning Inspections for Buildings Efficiency of Air Conditioning Systems

Air Conditioning Inspections for Buildings Efficiency of Air Conditioning Systems . Air Conditioning Inspections for Buildings Efficiency of Air Conditioning Systems PRESENTED BY NIRAJ MISTRY aircon@stroma.com Cooling Load The Refrigeration Load Cooling load on refrigeration system

More information

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012 SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES After studying this unit, the reader should be able to explain the purpose of the condenser in a refrigeration system. describe differences

More information

Technical Development Program

Technical Development Program Technical Development Program COMMERCIAL HVAC CHILLER EQUIPMENT Water-Cooled Chillers PRESENTED BY: Omar Rojas Sales Engineer Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7

More information

Midwest Industrial Initiative Webinar: Industrial Refrigeration

Midwest Industrial Initiative Webinar: Industrial Refrigeration Midwest Industrial Initiative Webinar: Industrial Refrigeration Opportunities for Energy Efficiency and Cost Savings Thursday, June 6, 2013 www.kw-engineering.com Bryan Hackett, PE kw Engineering What

More information

Automation and Energy Efficiency of Industrial Refrigeration Systems

Automation and Energy Efficiency of Industrial Refrigeration Systems Automation and Energy Efficiency of Industrial Refrigeration Systems E360 Forum Chicago, IL October 5, 2017 Mike Micak Director of Sales Logix Controls Introduction Management thinker Peter Drucker was

More information

MAYEKAWA MFG. CO., LTD Botan Koto-ku, Tokyo , JAPAN TEL:(81) FAX:(81)

MAYEKAWA MFG. CO., LTD Botan Koto-ku, Tokyo , JAPAN TEL:(81) FAX:(81) * mayekawa, MYCOM, NewTon are registered trademarks of Mayekawa Mfg.Co.,Ltd. * Subject to change without notice. MAYEKAWA MFG. CO., LTD. 3-14-15 Botan Koto-ku, Tokyo 135-8482, JAPAN TEL:(81)-3-3642-8181

More information

Energy Efficient Corn Drying. Kenneth Hellevang, Ph.D., P.E. Professor & Extension Engineer

Energy Efficient Corn Drying. Kenneth Hellevang, Ph.D., P.E. Professor & Extension Engineer Energy Efficient Corn Drying Kenneth Hellevang, Ph.D., P.E. Professor & Extension Engineer Estimated Corn Field Drying EMC (%) PET (in) Est. Drying (%pt) Month Week Sep 15 4.0-5.0 18 4.5 Oct 16 2.8-3.5

More information

The Ed Roberts Campus Berkeley, CA

The Ed Roberts Campus Berkeley, CA The Ed Roberts Campus Berkeley, CA Anderson Clemenceau Mechanical Option Penn State A.E. Senior Thesis April 14, 2015 Leddy Maytum Stacy Architects, Photo by Tim Griffith ASHRAE Climate Zone 3C 99.6% Heating

More information

MSP WRAP-AROUND MULTIPLE SMALL PLATE DEHUMIDIFICATION TECHNOLOGY VS. CONVENTIONAL DEHUMIDIFICATION IN DEDICATED OUTDOOR AIR SYSTEMS (DOAS)

MSP WRAP-AROUND MULTIPLE SMALL PLATE DEHUMIDIFICATION TECHNOLOGY VS. CONVENTIONAL DEHUMIDIFICATION IN DEDICATED OUTDOOR AIR SYSTEMS (DOAS) MSP WRAP-ARUND MULTIPLE SMALL PLATE DEHUMIDIFICATIN TECHNLGY VS. CNVENTINAL DEHUMIDIFICATIN IN DEDICATED UTDR AIR SYSTEMS (DAS) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++

More information

Partial Load Performance Of Refrigeration System

Partial Load Performance Of Refrigeration System Chapter 11 Partial Load Performance Of Refrigeration System Copy Right By: Thomas T.S. Wan 温到祥著 Sept. 3, 2008 All rights reserved Hot Gas Bypass & Liquid Injection: When the compressor is under surge condition,

More information

Case 13 Food Storage & Processing Center

Case 13 Food Storage & Processing Center Case 13 Food Storage & Processing Center Copy Right By: Thomas T.S. Wan ( ) Feb. 2, 2002 All Rights Reserved Case Background: The refrigeration system is for a food processing and storage facility. The

More information

Refrigeration and Boil Off Compression Systems for NGL Export Facilities

Refrigeration and Boil Off Compression Systems for NGL Export Facilities Refrigeration and Boil Off Compression Systems for NGL Export Facilities February 2015 2015 Gas/Electric Partnership Conference IHS INTERNATIONAL: US POISED TO LEAD WORLD EXPORTS OF LPG From Oil and Gas

More information

Kawasaki centrifugal chiller using water as a refrigerant. Sep 26 th 2017 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto

Kawasaki centrifugal chiller using water as a refrigerant. Sep 26 th 2017 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto Kawasaki centrifugal chiller using water as a refrigerant Sep 26 th 2017 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto Contents 1. Introduction of MiZTURBO 2. Study of CO 2 emissions

More information

Sivu 2/8 Rate data Description Suomi Shut off times total 0.0 h/day Weekends with shut off times yes Daytime rate of heat pump Time for daytime rate 5

Sivu 2/8 Rate data Description Suomi Shut off times total 0.0 h/day Weekends with shut off times yes Daytime rate of heat pump Time for daytime rate 5 Sivu 1/8 Design of a heat pump heating system with Aquarea Designer Project: Suomi 1 Date: Created by:?, (no data provided), (no data provided) Phone: (no data provided) Email: (no data provided) Building

More information

Agenda and Objectives

Agenda and Objectives Agenda and Objectives Trane Engineers Newsletter Live Series Variable-Speed Drives (VSDs) and Their Effect On HVAC System Components Variable-speed drives (VSDs) can save energy, but the savings may not

More information

PPL Electric Utilities Energy Efficiency and Conservation Program

PPL Electric Utilities Energy Efficiency and Conservation Program Installation of High-Efficiency High Efficiency Evaporator Fans Evaporator Fans That have Highfor Walk-ins Efficiency Permanent Split $50/fan motor Capacitor (PSC) Motor or ECM High Efficiency Compressors

More information

Update Dedicated Heat Recovery Chiller Technology. Don Frye. Gulf South

Update Dedicated Heat Recovery Chiller Technology. Don Frye. Gulf South 3/5/2018 1 Update Dedicated Heat Recovery Chiller Technology Don Frye Gulf South Good design is an intentional act Begin with the end in mind Basic Bldg Tenants IAQ (low VOC & CO 2 ) Controlled Temp &

More information

Cooling Options for Geothermal and Concentrating Solar Power Plants

Cooling Options for Geothermal and Concentrating Solar Power Plants Cooling Options for Geothermal and Concentrating Solar Power Plants EPRI Workshop on Advanced Cooling Technologies July 9, 2008 Chuck Kutscher National Renewable Energy Laboratory Geothermal Relevance

More information

McQuay. Screw Chiller Water Cooled. WHS Vintage A. Last Manufactured: Replacement Parts List No New 07/2012

McQuay. Screw Chiller Water Cooled. WHS Vintage A. Last Manufactured: Replacement Parts List No New 07/2012 Replacement s List No. 700024500 New 07/2012 McQuay Screw Chiller Water Cooled WHS 155-200 Vintage A Last Manufactured: 2000 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

Chiller Plant Design. Julian R. de Bullet President debullet Consulting Chiller Plant Design Julian R. de Bullet President debullet Consulting 703-483-0179 julian@debullet.com This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer ASHRAE

More information

Smardt Oil-Free Chillers

Smardt Oil-Free Chillers Smardt Oil-Free Chillers Company History in Brief Turbocor compressor invented in Australia in 1993 Turbocor was relocated to Montreal in 1999 Danfoss forms 50/50 partnership in 2004 Smardt was founded

More information

Industrial Refrigeration System using NH3/CO2 Refrigerant NewTon - For Cold Storage in Japan and Others -

Industrial Refrigeration System using NH3/CO2 Refrigerant NewTon - For Cold Storage in Japan and Others - Industrial Refrigeration System using NH3/CO2 Refrigerant NewTon - For Cold Storage in Japan and Others - Feb. 2014 Hideyo ASANO Mayekawa Mfg.Co.,Ltd. MYCOM JAPAN Basic Concept of NewTon Out door NewTon

More information

Central Drying/Conveying Systems

Central Drying/Conveying Systems Central Drying/Conveying Systems reduce operating costs, increase production, improve product quality and produce excellent payback. Central Drying/Conveying Systems Central Dryer Series : 200-5000 lb./hr.

More information

Strategies for Summer Utility Savings. Residential Environmental Program Series May 15, 2013

Strategies for Summer Utility Savings. Residential Environmental Program Series May 15, 2013 Strategies for Summer Utility Savings Residential Environmental Program Series May 15, 2013 Are FC Summers Getting Hotter? 200 Fort Collins Annual Hours 90 F or Above 150 100 50 1970 1980 1990 2000 2010

More information

ABSTRACT. 2 CanmetENERGY

ABSTRACT. 2 CanmetENERGY ABSTRACT In spring 2004, Loblaw Companies Limited (Loblaw) decided to innovate at their new Loblaws supermarket in Repentigny (QC) by adopting refrigeration technologies and operating practices pioneered

More information

Identification of Aberrant Railroad Wayside WILD and THD Detectors: Using Industry-wide Railroad Data. June 10, 2014

Identification of Aberrant Railroad Wayside WILD and THD Detectors: Using Industry-wide Railroad Data. June 10, 2014 Identification of Aberrant Railroad Wayside WILD and THD Detectors: Using Industry-wide Railroad Data June 10, 2014 1 Agenda Background / Overview Solution Approach Groupings Criteria Sites Speed Weight

More information

Hot Water a Hot Commodity Better Buildings by Design, February 2012 Burlington, VT

Hot Water a Hot Commodity Better Buildings by Design, February 2012 Burlington, VT Hot Water a Hot Commodity Better Buildings by Design, February 2012 Burlington, VT Gary Klein Affiliated International Management, LLC 916 549 7080 gary@aim4sustainability.com Gary Klein, 2012 Efficiency

More information

Using Adaptive Defrost Control Technology to Improve Energy Savings in the Food Service Industry.

Using Adaptive Defrost Control Technology to Improve Energy Savings in the Food Service Industry. White Paper Using Adaptive Defrost Control Technology to Improve Energy Savings in the Food Service Industry. Brian Lamberty Marketing Manager, HVAC/R Intermatic Incorporated Executive Summary Running

More information

Method to test HVAC equipment at part load conditions

Method to test HVAC equipment at part load conditions IPLV Method to test HVAC equipment at part load conditions For water cooled chillers: 100% load ( % hrs) + 75% ( Hrs ) + 50% ( Hrs ) + 25% ( Hrs ) = IPLV value Manufacturer can favor this number by tweaking

More information

Energy Performance of Low Charge NH3 Systems in Practice. Stefan S. Jensen

Energy Performance of Low Charge NH3 Systems in Practice. Stefan S. Jensen Energy Performance of Low Charge NH3 Systems in Practice Stefan S. Jensen Introduction Central type, dual compression stage, ammonia vapour compression systems. Main Design Features: Reciprocating Compressors

More information

2018 thesimple, Inc.

2018 thesimple, Inc. TM User Guide 2018 thesimple, Inc. Introduction The Simple thermostat supports supports 2 heating stages and 2 cooling stages for conventional systems, and 2 heating/cooling stages for heat pumps, with

More information

TrilliumSeries Condenser 1 TRILLIUMSERIES CONDENSER 10 ECOFLEX CONTROLS 11 SELECTION AND PAYBACK ANALYSIS SOFTWARE 3 BENEFITS 8 MODES OF OPERATION

TrilliumSeries Condenser 1 TRILLIUMSERIES CONDENSER 10 ECOFLEX CONTROLS 11 SELECTION AND PAYBACK ANALYSIS SOFTWARE 3 BENEFITS 8 MODES OF OPERATION TrilliumSeries Condenser T A B L E O F C O N T E N T S 1 TRILLIUMSERIES CONDENSER 3 BENEFITS 8 MODES OF OPERATION 9 ENGINEERING DATA 10 ECOFLEX CONTROLS 11 SELECTION AND PAYBACK ANALYSIS SOFTWARE 12 CO

More information

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb. HVAC Math The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb. Math F. to C. Conversion = (f-32)*(5/9) C. to F. Conversion = C * 9/5 +

More information

Kimberly Rollins, Professor, Department of Economics, University of Nevada, Reno

Kimberly Rollins, Professor, Department of Economics, University of Nevada, Reno Modeling Multiple Factors of Residential Water Demand to Assess Price and Non-Price Instruments under Climate Change: An Application to Las Vegas, Nevada Kimberly Rollins, Professor, Department of Economics,

More information

Energy Use in Refrigeration Systems

Energy Use in Refrigeration Systems 2012 Rocky Mountain ASHRAE Technical Conference Energy Use in Refrigeration Systems PRESENTED BY: Scott Martin, PE, LEED AP BD+C Objectives Understand mechanical refrigeration terms Describe how heat is

More information

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria Mechanical System Redesign Dedicated Outdoor Air System Design Criteria The outdoor air conditions used were for Philadelphia, Pennsylvania IAP at a 0.4% occurrence. The supply air conditions were developed

More information

Design and Operation of a Conditioning Energy Recovery Ventilator (CERV) for Passive Houses

Design and Operation of a Conditioning Energy Recovery Ventilator (CERV) for Passive Houses Design and Operation of a Conditioning Energy Recovery Ventilator (CERV) for Passive Houses Ben Newell and Ty Newell January 22, 2009 Newell Instruments Inc. 1103 N High Cross Rd Urbana, IL 61802 Phone:

More information

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Technical Development Program COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Introduction System

More information

A Case Study on. Energy Management Control System for. Refrigeration Plant. Nestle Ice Cream Plant Mulgrave

A Case Study on. Energy Management Control System for. Refrigeration Plant. Nestle Ice Cream Plant Mulgrave A Case Study on Energy Management Control System for Refrigeration Plant Nestle Ice Cream Plant Mulgrave Summary Nestle s ice cream plant, located on Wellington Road in Mulgrave Victoria, utilises a very

More information

E X V sistema Precision mechanics, powerful control. carel.com. connectivity, monitoring and remote managem,ent systems

E X V sistema Precision mechanics, powerful control. carel.com. connectivity, monitoring and remote managem,ent systems connectivity, monitoring and remote managem,ent systems electronic expansion valves and drivers E X V sistema Precision mechanics, powerful control carel.com E X V sistema - a complete range of electronic

More information

Engineered for flexibility and performance

Engineered for flexibility and performance Centrifugal Chillers 200 to 2700 tons Engineered for flexibility and performance Daikin McQuay Single Compressor Centrifugal Chillers A Life Cycle Return on Your Investment Centrifugal chillers are a significant

More information

Daikin Altherma Selection Report

Daikin Altherma Selection Report Daikin Altherma Selection Report Produced on 20.10.2014 with Daikin Altherma Simulator V4.4.7 - database Central 9.7.9 Project name Energa Sistemi Reference Airabela Client name Energa Sistemi Revision

More information

MCH Series Drives. HVAC Application Guide. ag-mch-e2

MCH Series Drives. HVAC Application Guide. ag-mch-e2 Drives HVAC Application Guide ag-mch-e2 % Flow, Torque, HP AFFINITY LAWS Most HVAC systems are designed to perform during peak load conditions that rarely occur during the year. Various flow control methods

More information

Central Drying/ Conveying Systems

Central Drying/ Conveying Systems Central Dryer Series : 200-5000 lb/hr (90-2272 Kg/hr) Central Drying/ Conveying Systems Central drying/conveying systems reduce operating costs, increase production, improve product quality and produce

More information

Shifting Patterns of Water Demand: Socio-Demographic Challenges for Water Managers

Shifting Patterns of Water Demand: Socio-Demographic Challenges for Water Managers Intro Page Shifting Patterns of Water Demand: Socio-Demographic Challenges for Water Managers Gary Woodard, Ass t. Director NSF STC for Sustainability of Semi-Arid Hydrology and Riparian Areas (SAHRA)

More information

BASE LEVEL AUDIT REQUIREMENTS REFRIGERATION SYSTEMS 1. SITE DATA COLLECTION. Business Name. Site physical address (Street, Suburb, City)

BASE LEVEL AUDIT REQUIREMENTS REFRIGERATION SYSTEMS 1. SITE DATA COLLECTION. Business Name. Site physical address (Street, Suburb, City) BASE LEVEL AUDIT REQUIREMENTS REFRIGERATION SYSTEMS 1. SITE DATA COLLECTION Business Name Site physical address (Street, Suburb, City) Nature of site / business operation Electricity Supplier Power factor

More information

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU Chillers and Refrigerants APPA Institute for Facilities Management Providence, RI September, 2017 1 Purpose of Today s Presentation To provide a broad understanding of chillers and central cooling systems

More information

Innovative Technologies [and Design Concepts] in Commercial Foodservice

Innovative Technologies [and Design Concepts] in Commercial Foodservice Innovative Technologies [and Design Concepts] in Commercial Foodservice Don Fisher, P. Eng. Fisher Consultants PG&E Food Service Technology Center 925-866-5770 dfisher@fishnick.com Food Service Technology

More information

opti-visor ultra-efficient chiller plant automation Typical specification

opti-visor ultra-efficient chiller plant automation Typical specification opti-visor ultra-efficient chiller plant automation Typical File No: 90.893 Date: february 9, 2015 Supersedes: 90.893 Date: april 20, 2012 contents 1.0 Chilled water plant 4 1.1 General system requirements

More information

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems IMPORTANT NOTICE: This sample document is provided for instructional purposes only. CCC is not rendering advice concerning any commission project or practices. This document is neither approved nor intended

More information

Wisconsin s Annual Potato Meeting, Stevens Point, WI - February 14-16, 2006 Page 1

Wisconsin s Annual Potato Meeting, Stevens Point, WI - February 14-16, 2006 Page 1 Benefits of Adjustable Speed Fans for Bulk Potato Storage Ventilation Systems Scott A. Sanford Senior Outreach Specialist Biological Systems Engineering University of Wisconsin - Madison Introduction Potato

More information

H EDRICK ASSOCIATES OF GRAND RAPIDS West Michigan s Factory Representative

H EDRICK ASSOCIATES OF GRAND RAPIDS West Michigan s Factory Representative A U.S. Environmental Protection Agency survey released in 2007 concluded that IT data centers consumed 61 billion kw of electricity at a total cost of $4.5 billion in 2006. As energy costs continue to

More information

Buran. Cycling Refrigerated Compressed Air Dryer With Ultrapulse Control. Intelligent Energy Management

Buran. Cycling Refrigerated Compressed Air Dryer With Ultrapulse Control. Intelligent Energy Management Buran Cycling Refrigerated Compressed Air Dryer With Ultrapulse Control Intelligent Energy Management The intelligent, energy efficient dryer. ENERGY EFFICIENCY Energy efficient operation remains of paramount

More information

System Using Exhaust Heat from Residential GHPs

System Using Exhaust Heat from Residential GHPs Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2000 System Using Exhaust Heat from Residential GHPs K. Tanokashira Tokyo Gas

More information

Laboratory Evaluation of Hybrid and Advanced Water Heaters: Performance Overview in Hot Humid Climate

Laboratory Evaluation of Hybrid and Advanced Water Heaters: Performance Overview in Hot Humid Climate Laboratory Evaluation of Hybrid and Advanced Water Heaters: Performance Overview in Hot Humid Climate American Council for an Energy Efficient Economy ACEE Hot Water Forum Nov. 4-5, 2013 Carlos J. Colon

More information

WLAC Facilities Committee Meeting. September 18, 2017

WLAC Facilities Committee Meeting. September 18, 2017 Campus Program Report WLAC Facilities Committee Meeting September 18, 2017 Page 1 DSA approved the plans on May 15, 2017. Notice to Proceed was issued June 8, 2017 and the project remains on schedule for

More information

ProMoss TM Plant-Based Water Treatment Solves Problems in Tobacco Manufacturing Plant Air Washer Systems

ProMoss TM Plant-Based Water Treatment Solves Problems in Tobacco Manufacturing Plant Air Washer Systems Case Study ProMoss TM Plant-Based Water Treatment Solves Problems in Tobacco Manufacturing Plant Air Washer Systems Steve Chewning, CWT, James Hall, Southeastern Laboratories, Inc. August 2017 Air washer

More information

REFRIGERATION EQUIPMENT SCOPE - QUESTIONNAIRE

REFRIGERATION EQUIPMENT SCOPE - QUESTIONNAIRE REFRIGERATION EQUIPMENT SCOPE - QUESTIONNAIRE Please provide the following information to receive a no-cost estimate of how much money our control system could save your facility and to assist us in preparing

More information

Data driven insights from the nation s deepest ever customer energy research

Data driven insights from the nation s deepest ever customer energy research Pecan Street Research Institute Pike Powers Lab and Center for Commercialization Data driven insights from the nation s deepest ever customer energy research Change in peak load 70,000 by customer class

More information

Life Cycle Cost Of Selecting Chiller Equipment: Manufacturer s Viewpoint. Daryl Showalter ChillerApplications Manager McQuay International

Life Cycle Cost Of Selecting Chiller Equipment: Manufacturer s Viewpoint. Daryl Showalter ChillerApplications Manager McQuay International Life Cycle Cost Of Selecting Chiller Equipment: Manufacturer s Viewpoint Daryl Showalter ChillerApplications Manager McQuay International Equipment Using Different Kinds Of Equipment Or Different Performance

More information

Process glycol chillers

Process glycol chillers Process glycol chillers The most advanced solutions in refrigeration technology. According to normative EN378 y F-Gas Compact chillers for outdoor installation Natural refrigerant Integrated hydraulic

More information

AIR HANDLING SYSTEM RETRO-COMMISSIONING TRENDING ANALYSIS

AIR HANDLING SYSTEM RETRO-COMMISSIONING TRENDING ANALYSIS AIR HANDLING SYSTEM RETRO-COMMISSIONING TRENDING ANALYSIS 1 AIR HANDLING UNIT TRENDS 2 1. The trending charts provided on the following pages prepared as part of a retro-commissioning investigation. The

More information

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications A Technical Introduction to Cool Thermal Energy Storage Commercial Applications Cool Thermal Energy Storage is a new application of an old idea that can cut air conditioning energy costs in half while

More information

Parilla Thermal Storage Project Case Study. May Page 1 of 11

Parilla Thermal Storage Project Case Study. May Page 1 of 11 Parilla Thermal Storage Project Case Study May 2014 Page 1 of 11 BACKGROUND Parilla Premium Potatoes is a large refrigerated storage facility (Figure 1) located in South Australia; the facility consists

More information

Feature Summary. I. System

Feature Summary. I. System I. System A. Supports up to 60 VAV HVAC Units 1. Each HVAC Unit Can Support up to 59 VAV Boxes 2. Constant Volume Units Can Be Integrated With VAV Units 3. System Can Support Over 3000 Controllers B. Fill-in

More information

BN-ACCMX MAR 2016 Replaces BN-TB-ACCMX MAR Air-Cooled Condenser. with Microchannel Coil Technology Models NRG NRJ

BN-ACCMX MAR 2016 Replaces BN-TB-ACCMX MAR Air-Cooled Condenser. with Microchannel Coil Technology Models NRG NRJ BN-ACCMX MAR 2016 Replaces BN-TB-ACCMX MAR 2015 Air-Cooled Condenser with Microchannel Coil Technology Models NRG NRJ Table of Contents Nomenclature... 2 Features & Benefits... 3 Capacity and Specifications...

More information

Technical Development Program

Technical Development Program Technical Development Program PRESENTED BY: James Parker Insert your logo here AIR HANDLERS Coils: Direct Expansion Chilled Water and Heating Menu Section 1 Introduction Section 2 Typical Coil Applications

More information

Unvented Roof Summary Article

Unvented Roof Summary Article building science.com 2008 Building Science Press All rights of reproduction in any form reserved. Unvented Roof Summary Article Research Report - 0301 2003 Kohta Ueno Abstract: This article was written

More information

Understanding Head Pressure Control. Walter H Langille, M.A.Sc., P.Eng Sales Engineer KeepRite Refrigeration

Understanding Head Pressure Control. Walter H Langille, M.A.Sc., P.Eng Sales Engineer KeepRite Refrigeration Understanding Head Pressure Control Walter H Langille, M.A.Sc., P.Eng Sales Engineer KeepRite Refrigeration WE WILL LOOK AT: 1. Why We Need Head Pressure Control? 2. How Do We Control Head Pressure - Methods?

More information

Heat Recovery Systems PTG, SWT Series.

Heat Recovery Systems PTG, SWT Series. Heat Recovery Systems PTG, SWT Series www.kaeser.com Why recover heat? The question should in fact be: Why not recover heat? Amazingly, almost 100 percent of the electrical energy input to a compressor

More information

Improving Cold Chain Competitiveness with Danfoss Energy Efficiency Solutions.

Improving Cold Chain Competitiveness with Danfoss Energy Efficiency Solutions. Improving Cold Chain Competitiveness with Danfoss Energy Efficiency Solutions www.danfoss.com Agenda Brief on Danfoss Danfoss Business Divisions / Areas Danfoss Drive Solutions for Energy Efficiency in

More information

Chiller Plant Design. Application Guide AG McQuay International. Elevation Difference. Column Height When Pump Is Off

Chiller Plant Design. Application Guide AG McQuay International. Elevation Difference. Column Height When Pump Is Off Application Guide AG 31-003-1 Chiller Plant Design 51.5F Return Water To Chiller Two 400 Ton Chillers Each At 300 Tons (Balanced Load) 51.5F 480 gpm Flow Through Decoupler 44F 54F Building Load 600 Tons

More information

Performance of Solar Water Heating Systems in the United States

Performance of Solar Water Heating Systems in the United States Performance of Solar Water Heating Systems in the United States Danny Parker & Camilo Gil Florida Solar Energy Center ACEEE Hot Water Forum June 2009, Asilomar,, California Rebate situation in Florida

More information

R4 Ventures LLC White Paper

R4 Ventures LLC White Paper R4 Ventures LLC White Paper Preliminary Temperature Performance Evaluation of New Cooling Technologies consisting of the Multistage Evaporative Cooling System (MECS) for Phoenix, AZ; Newark, DE; Houston,

More information

Cork County Energy Agency

Cork County Energy Agency Cork County Energy Agency Energy Audit Midleton Area Office December 2009 Table of Contents 1. Introduction...1 2. Site description...2 3. On site energy use...3 3.1 Energy management...3 3.2 Breakdown

More information

THERMAL ICE STORAGE: Application & Design Guide

THERMAL ICE STORAGE: Application & Design Guide THERMAL ICE STORAGE: Application & Design Guide Table of Contents: 1. Introduction A. History of Thermal Energy Storage B. Operating and Cost Benefits 2. Applications A Fundamental System B. HVAC Cooling

More information

energydesignresources

energydesignresources energydesignresources design brief Energy building Efficiency design Practices in Industrial Refrigeration Summary Energy costs are a significant expense for facilities that operate industrial refrigeration

More information

DIGI-CRAC DIGI-CRAH South 59 th Street Omaha, NE bes- tech.net

DIGI-CRAC DIGI-CRAH South 59 th Street Omaha, NE bes- tech.net Digi-CRAC/H DIGI-CRAC Digi-CRAC is an aftermarket control package designed for DX data center air-conditioning units. Modulating the compressor and fan speed to match output to the space needs. DIGI-CRAH

More information