NEWIN Centrifual Fan Forced Draft Cooling Tower Product Introduction

Size: px
Start display at page:

Download "NEWIN Centrifual Fan Forced Draft Cooling Tower Product Introduction"

Transcription

1 Product Introduction NCF series centrifugal fan forced draft cooling tower is a type of cooling tower designed to protect the environment from our years of cooling tower equipment design, production, operation, maintenance experience, combined the advanced heat exchange technology and scientific production management, it is an advanced innovation product. NCF series cooling tower is all-metal construction, avoided to cause any harm to the environment and human body regarding the production process of FRP material, and also avoided serious impact to the environment and ecological balance during the long term degradation process of FRP. Casing is made of zinc magnesium aluminum or stainless steel plate, equiped with low noise multi-wheel centrifugal fans. The fan and its driven system are installed at the bottom of cooling tower, it easily makes to control the noise level, and avoided the corrosion caused by saturated moisture, ensured longer service life and facilitated cooling tower of daily maintenance work. Closed water basin can effectively isolated direct sunlight to the cooling water, effectively controlled the algae bacteria breeding and avoid causing bacteria "veterans". NCF series centrifugal fan forced draft cooling tower adopts the single side into the wind design, can undertake more towers assembling, suitable application in indoor, outdoor and tunnel, etc. -1-

2 Features Beautiful appearance, flexible combination, high thermal efficiency, small footprint, environmental protection, low noise, easy maintenance, long service life. Frame structure: Modular structure, use the high quality of zinc magnesium aluminum material (304 or 316 stainless steel for option), which is standardization made by Z600 galvanized anti-corrosion processing. After passivation treatment, cooling tower can withstand water PH value At the same time, the component design strength can bear the wind pressure of 1440 Pa, Protected the product quality and ensured stable running. Equipment can be ordered according to singlecell or multi cells. Casing Using high quality imported galvanized aluminum plate, high strength, strong anti-corrosion ability, beautiful appearance, smooth and easy assembly, etc. Centrifugal fan Using the centrifugal fan, through static and dynamic test of production process, to meet the cooling tower heat transfer performance under the premise of maximum noise reduction. Driven system Using multi channel V belt transmission, the design of the belt based on 150% of the motor rated power. Smooth running, low noise, fan bearing with conical roller bearing, large carrying capacity, long life, rated life over 20,000 hours Motor Using closed cooling tower dedicated motor, IP55 protection grade, insulation class is F, suitable for hot and humid environment to run for a long time. Products comply with IEC international standards, with high efficiency, low noise, long life, reliable operation, etc Fill media Using the high quality of modified PVC materials, the heating vacuum forming the diaphragm of the wet packing, with uv resistance, chemical resistance, changing the characteristics of high thermal efficiency. Drift eliminator Using high quality cellular drift eliminator, not only the small resistance, and effectively reduced cooling water loss dropped to no more than 0.001% of the circulating water. Nozzle Using independent design of the nozzle of our company. The nozzle sprays the water uniformly under the condition of low pressure water, adopts the design of large diameter, internal without moving parts, maintenance free, small resistance, greatly improved thermal efficiency of cooling tower. Access gallery The access door is designed at both ends of the cooling tower, convenient access to the fan room for repairing or maintenance work. -2-

3 Water basin Using the high quality steel plate thickness profile, supporting the various pipeline interface, outlet is also equipped with filter, hydrating mouth built-in brass valves, large diameter plastic floating ball, automatically adjust the water level, water plate design for large capacity, high water level. Construction Material Model NCF- NCF-S NCF-SS Frame galvanized magnesium Casing aluminum plate Water Basin 304# stainless steel 316# stainless steel Bolts&Nuts 304# stainless steel 304# stainless steel 316# stainless steel Nozzle ABS plastic Fill Media PVC film fill Drift Eliminator PVC celluar type Fan Zinc-coated centrifugal fan Sinlencer Asbestos board -3-

4 Technical Parameters Item Water flow Power Dimension (mm) Weight (kg) Model m³/h kw Length Height Inlet pipe Outlet pipe Net Operation L H diameter diameter weight weight NCF NCF NCF NCF NCF NCF NCF NCF NCF NCF NCF x NCF x NCF x NCF x Design condition: Inlet hotwater temperature 35, Outlet cold water temperature 29.5, Design wet bulb temperature: 25.5 ; Atmosphere: 99.4Kpa. Outline Dimension -4-

5 Outline Dimension With Silencer Model Dimension A B C NCF100 ~ NCF180 ~ NCF265 ~ Foundation ` Model NCF-100 NCF-125 NCF-135 NCF-150 NCF-165 NCF-180 NCF-200 NCF-220 NCF-235 NCF-250 NCF-265 NCF NCF-305 Remarks: NCF The above drawing are the initial layout, Please ask for detailed drawing when place order. 2. We reserve the rights to modify the above parameters without further notice. D

LSFG-8 LOW SOUND & SLSFG-10 SUPER LOW SOUND TOWER FEATURES

LSFG-8 LOW SOUND & SLSFG-10 SUPER LOW SOUND TOWER FEATURES The Leaders in All-Fiberglass Cooling Towers REYMSA s success is the result of 35 years of experience in cooling towers. We have been putting ideas into action by researching and developing the latest

More information

Fibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning.

Fibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning. 1 3 2 4 5 Closed Circuit Cooling Tower Factory Assembled - Modular Compact Design 1 IP56 Motor(s) directly coupled to low energy and high efficient fan(s) 2 Fibreglass reinforced polyester (FRP) sandwich

More information

What is a Closed circuit Cooling Tower (CCT)?

What is a Closed circuit Cooling Tower (CCT)? What is a Closed circuit Cooling Tower (CCT)? Closed circuit Cooling Towers are hybrids that pass the working fluids through a tube bundle, upon which clean water is sprayer and a faninduced draft applied.

More information

Mr. GoodTower Service Center

Mr. GoodTower Service Center GTSC-E 0615 Mr. GoodTower Service Center Specialists in Replacement Parts and Maintenance of Evaporative Cooling Equipment Call now for a free inspection on your Evaporative Cooling equipment to: Extend

More information

CROSSFLOW FILM FILL PACKAGE COOLING TOWER. Number TYH SERIES LOW NOISE - ENERGY SAVINGS. Thermal-Cell Sdn Bhd ( M)

CROSSFLOW FILM FILL PACKAGE COOLING TOWER. Number TYH SERIES LOW NOISE - ENERGY SAVINGS. Thermal-Cell Sdn Bhd ( M) CROSSFLOW FILM FILL PACKAGE COOLING TOWER Number 11-40-01 TYH SERIES LOW NOISE - ENERGY SAVINGS Thermal-Cell Sdn Bhd (155-M) TYH SERIES Rectangular Cross Flow Cooling Tower is more superior on its motor,

More information

PAD. Adiabatic cooler. PAD series

PAD. Adiabatic cooler. PAD series Adiabatic cooler MITA Adiabatic cooler General information Adiabatic cooling is a thermodynamic phenomenon by which air temperature is decreased through humidification. The temperature than can be reached

More information

LOW STATIC HYDRONIC DUCTED UNIT

LOW STATIC HYDRONIC DUCTED UNIT LOW STATIC HYDRONIC DUCTED UNIT PDWA-~AC SERIES PDWA(4R)-~-V-MEDC PDWA(4R)-~-V-MEEU PDWA(R)-~-V PDWA(R+1)-~-P Model cooling capacity( KW) at Medium Speed cooling capacity (KW) at Medium Speed cooling capacity

More information

Presenters. Brett Alexander. Mihir Kalyani. Troy Reineck

Presenters. Brett Alexander. Mihir Kalyani. Troy Reineck ow Brett Alexander Presenters Mihir Kalyani Troy Reineck Designing Your Water Treatment Program for Different Types of Heat Rejection Equipment Types of Heat Rejection Equipment Open Cooling Tower Closed

More information

VTL Open Cooling Towers... B98. Benefits... B100. Construction Details... B102. Custom Features and Options... B103. Accessories...

VTL Open Cooling Towers... B98. Benefits... B100. Construction Details... B102. Custom Features and Options... B103. Accessories... . - B 97 Product Detail... B98 Benefits... B100 Construction Details... B102 Custom Features and Options... B103 Accessories... B Engineering Data... B107 Structural Support... B111 Engineering Specifications...

More information

Baltimore Aircoil RCF CLOSED CIRCUIT COOLING TOWERS. ...because temperature matters COUNTERFLOW INDUCED DRAFT

Baltimore Aircoil RCF CLOSED CIRCUIT COOLING TOWERS. ...because temperature matters COUNTERFLOW INDUCED DRAFT CLOSED CIRCUIT COOLING TOWERS COUNTERFLOW INDUCED DRAFT GENERAL DESCRIPTION: Commercial applications demand reliable, cost effective and energy efficient solutions. With an ever increasing focus on operational

More information

What is Cooling S.Sen

What is Cooling S.Sen What is Cooling Tower @ S.Sen Gear Box Stack Shaft Fan Blade Motor Fill Theory of Cooling Towers Cooling towers fall into two main sub-divisions: natural draft and mechanical draft. Natural draft designs

More information

SECTION COOLING TOWERS

SECTION COOLING TOWERS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 65 00 COOLING TOWERS SPEC WRITER NOTES: 1. DELETE BETWEEN //---// if not applicable to project. Also delete any other item or paragraph not applicable in the

More information

Closed Circuit Cooling Towers

Closed Circuit Cooling Towers Closed Circuit Cooling Towers Overview Closed circuit cooling towers provide evaporative cooling for many types of systems, and the specific application will largely determine which BAC Closed Circuit

More information

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/ 1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5

More information

Series 1500 Cooling Tower Specification

Series 1500 Cooling Tower Specification 1.0 Cooling Tower Series 1500 Cooling Tower Specification 1.1 General: Furnish and install factory-assembled, induced draft, crossflow cooling tower(s) with vertical air discharge conforming in all aspects

More information

Closed Circuit Cooling Towers

Closed Circuit Cooling Towers VFL - C 35 Closed Circuit Cooling Towers Product Detail VFL Closed Circuit Cooling Tower... C36 Benefits... C38 Construction Details... C40 Custom Features and Options... C41 Accessories... C43 Engineering

More information

Commercial Evaporative Cooling

Commercial Evaporative Cooling Commercial Evaporative Cooling The Bonaire System Advantage Bonaire has been providing innovative commercial evaporative cooling solutions for over 60 years on projects with applications which have been

More information

DESCRIPTION OF COOLING TOWERS SERIES TAT

DESCRIPTION OF COOLING TOWERS SERIES TAT DESCRIPTION OF COOLING TOWERS SERIES TAT The TAT series are dedicated to every industrial sector with a modular conception. These models are characterized by SCAM T.P.E. S.r.l. well defined standards and

More information

Evaporative Condensers

Evaporative Condensers J2 BAC offers evaporative condensers in six different styles to suit every industry application. CXV Models - CXV models deliver efficient performance in an easy-to-maintain package. BAC s combined flow

More information

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5

More information

JCseries EVAPORATIVE CONDENSER. engineering data

JCseries EVAPORATIVE CONDENSER. engineering data JCseries EVAPORATIVE CONDENSER engineering data Recold JC Series Evaporative Condenser Contents 2 Construction... 3 Schematic... 4 Engineering Data... 5 Selection Procedure... 6-9 Multi-Circuited Selection

More information

DESCRIPTION WATER COOLING TOWER TAS/TASF (*) SERIES

DESCRIPTION WATER COOLING TOWER TAS/TASF (*) SERIES DESCRIPTION WATER COOLING TOWER TAS/TASF (*) SERIES The TAS / TASF SERIES are dedicated to every industrial sector with a modular conception. These models are characterized by SCAM T.P.E. S.r.l. well defined

More information

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF New CGAF New Air-Cooled Scroll Chiller CGAF New CGAF CGAF Air cooled Scroll Chiller 170 700 kw Cooling Only CXAF 150 700 kw Heat pump Coming soon 2 New addition to the Sintesis Family: Multiple technologies,

More information

Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower

Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower 1.0 Closed Circuit Hybrid Cooling Tower 1.1 General: Furnish and install, as shown on the plans, factory-assembled closed circuit

More information

Evaporative Condensers

Evaporative Condensers VXC - E 13 Evaporative Condensers Product Detail VXC Evaporative Condensers... E14 Benefits... E16 Construction Details... E18 Custom Features and Options... E20 Accessories... E22 Engineering Data...

More information

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM 0,7 kw 5,2 kw 1,6 kw 10,2 kw 130 m 3 /h 830 m 3 /h SLIM SLIMxx0 vertical with cabinet bottom vertical Available also with feet SLIMxx8 SLIMxx5 SLIMxx4 SLIMxx9

More information

SNOWCOOL SYSTEMS INDIA PVT LTD.

SNOWCOOL SYSTEMS INDIA PVT LTD. SNOWCOOL SYSTEMS INDIA PVT LTD. PRESENTS LARGEST RANGE OF COOLING TOWERS CAPACITIES WATER FLOW 10 CMH TO 100000 CMH HOT WATER 35 C TO 85 C CONSTRUCTION FRP & RCC SINGLE & MULTIPLE CELLS CUBICAL & HYPERBOLIC

More information

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

Hygro and Hygrothermo Transducers (capacitive) for climatic applications Data sheet 907020 Page 1/7 Hygro and Hygrothermo Transducers (capacitive) for climatic applications To measure relative humidity and temperature For versatile climatic applications and ventilation For

More information

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit MODEL: ACW200D ACW300D ACW400D ACW500D ACW600D ACW800D ACW900D ACW1000D ACW1200D ACW1400D ACWD-2006 ACWD_2006_Cover.indd 1 CEILING CONCEALED Chilled Water Fan Coils Unit 2006-5-25 17:24:07 Contents Main

More information

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T is characterized by having no additional moisture added

More information

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65% Dry HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES Calculation of savings (for illustrative purposes) Operating scheme Note: power rates refer to 10,000 m 3 /h of air and

More information

Operation & Maintenance of Cooling Tower

Operation & Maintenance of Cooling Tower Operation & Maintenance of Cooling Tower 1 Contents Basic of Cooling Towers Types of Cooling Tower Preparation for Startup Startup Cooling Tower Caution During Operation Water Quality Maintenance & Control

More information

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU) AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory

More information

Privately held company

Privately held company WELCOME Founded in 1948 by our late Chairman, Mr Mahendra Swarup Privately held company Designing and manufacturing evaporative water cooling towers and other products related to process cooling for over

More information

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T-TWIN is characterized by having no additional moisture

More information

Centrifugal Blower. Backward/Aerofoil Curved.

Centrifugal Blower. Backward/Aerofoil Curved. Centrifugal Blower Backward/Aerofoil Curved www.humidin.com Centrifugal Blower Backward/Aerofoil Curved When Quality Speaks For Itself As a leading manufacturer of Centrifugal Blower Backward/Aerofoil

More information

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview Product overview 1 Company Profile Yantai Oceanair Refrigeration & Air-Conditioning Co.,Ltd. was established in 2004 and has been listed on the New OTCBB (Stock Code: 831870). We are mainly specialized

More information

Compass Series Open Cooling Towers

Compass Series Open Cooling Towers Compass Series Open Cooling Towers Compass Series Benets Baltimore Aircoil Company (BAC) is the world s largest and leading supplier of evaporative heat transfer and thermal energy management equipment.

More information

Commercial Evaporative Air Conditioning

Commercial Evaporative Air Conditioning Commercial Evaporative Air Conditioning The Bonaire System Advantage Bonaire has been providing innovative commercial evaporative cooling solutions for over 60 years on projects with applications which

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

CROSSFLOW REPLACEMENT FILL KITS. Replacement Fill Kits Specifically Designed for All Types of Crossflow Cooling Towers (BAC, Marley, etc.

CROSSFLOW REPLACEMENT FILL KITS. Replacement Fill Kits Specifically Designed for All Types of Crossflow Cooling Towers (BAC, Marley, etc. CROSSFLOW REPLACEMENT FILL KITS Replacement Fill Kits Specifically Designed for All Types of Crossflow Cooling Towers (BAC, Marley, etc.) Hanging Verses Pack Hanging fill is installed in some manufacturers

More information

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL Section 23 20 00 FLUID SYSTEMS EQUIPMENT PART 1 GENERAL 1. CHILLERS Page 23 20 00-1 A. Provide chiller packages with centrifugal compressors, or screw compressors, and water cooled condensers. B. Design

More information

/ Aquatower Fiberglass Cooling Tower /

/ Aquatower Fiberglass Cooling Tower / / Aquatower Fiberglass Cooling Tower / Aquatower Fiberglass Cooling Tower / Features and Benefits 2 Proven Performance. CTI Certified. Plus SPX stands by its responsibility for reliable thermal performance.

More information

SECTION STEAM CONDENSATE PUMPS

SECTION STEAM CONDENSATE PUMPS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 22 23 STEAM CONDENSATE PUMPS SPEC WRITER NOTES: 1. Delete between // ---- // if not applicable to project. Also delete any other item or paragraph not applicable

More information

Leadership, Innovation, Advanced Technology Synergise Here!

Leadership, Innovation, Advanced Technology Synergise Here! Cooling Synergies Leadership, Innovation, Advanced Technology Synergise Here! 125 years of Engineering Innovation Kirloskar Chillers is proud to be a part of 125 years old Kirloskar Group. The diversified

More information

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut Featuring Ozone-safe HFC134a Hitachi Centrifugal Chillers NEW GXG-S Series GSG-S Series Debut Centrifugal Chiller New GXG-S, GSG-S Series Debut High-efficiency New series Centrifugal Chillers that use

More information

AIR HANDLER SPECIFICATION

AIR HANDLER SPECIFICATION AIR HANDLER SPECIFICATION Air Handlers AH-1 through 5 The following air handlers will be supplied: AH-1 FX15-4842 Series 5700 CFM AH-2 FX15-4236 Series 3990 CFM AH-3 FX15-3633 Series 2570 CFM AH-4 FX15-3330

More information

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 25,240* Design CFM: 800 Seasonal

More information

AT, MT & ES Series Super Low Sound Fan

AT, MT & ES Series Super Low Sound Fan AT, MT & ES Series Super Low Sound Fan The EVAPCO Super Low Sound Fan utilises an extremely wide chord blade design for sound sensitive applications where the lowest sound levels are desired. The fan is

More information

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs Q: How is the WSAC a closed-loop cooling system? A: The WSAC is a closed-loop cooling system because the process loop being cooled is inside the tube bundles

More information

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T-TWIN is characterized by having no additional moisture

More information

3PT HITCH MOUNTED MIST BLOWER AT LOW VOLUME

3PT HITCH MOUNTED MIST BLOWER AT LOW VOLUME -S 3PT HITCH MOUNTED MIST BLOWER AT LOW VOLUME NP General features -S hot galvanized steel frame; POLYETHYLENE tank with liquid level gauge; outlet system with external ecology valve; diaphragm pump l/min

More information

Product Introduction...D85. Benefits...D87. Construction Details...D89. Custom Features & Options...D91. Accessories...D93. Engineering Data...

Product Introduction...D85. Benefits...D87. Construction Details...D89. Custom Features & Options...D91. Accessories...D93. Engineering Data... Series V Product Detail Product Introduction..................................D85 Benefits...............................................D87 Construction Details...................................D89 Custom

More information

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS SECTION 236200 - PACKAGED COMPRESSOR AND CONDENSER UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions apply

More information

Vibration Of Cooling Tower Fans. Barry T. Cease Cease Industrial Consulting Vibration Institute 2015

Vibration Of Cooling Tower Fans. Barry T. Cease Cease Industrial Consulting Vibration Institute 2015 Vibration Of Cooling Tower Fans Barry T. Cease Cease Industrial Consulting Vibration Institute 2015 ceasevibration@icloud.com (843) 200-9705 1 WHAT IS A COOLING TOWER AND WHAT DOES IT DO? All cooling towers

More information

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013 SECTION 15800 - AIR HANDLING EQUIPMENT 1.1 GENERAL A. All air handlers installed shall conform to the University of Rochester specification Guideline for Semi-Custom and Pre-Engineered Air Handling Units.

More information

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Compact, Self-Contained unit that offer low installation cost plus dependable performance. 0 Compact, Self-Contained unit that offer low installation cost plus dependable performance. From carrier s excellence in engineering come a new, compact of single package horizontal and vertical water

More information

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES Range 3.6 To 36.5 Tons 50Hz R22 TABLE OF CONTENT General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators

More information

Reliable products with long-term, low cost of ownership

Reliable products with long-term, low cost of ownership Evaporative Condensers Reliable products with long-term, low cost of ownership For Industrial Refrigeration EVAPORATIVE CONDENSERS Why buy FRICK products? FRICK History includes a great reputation for

More information

ENGINEERING DATA AND SPECIFICATIONS. Marley Aquatower FIBERGLASS CROSSFLOW COOLING TOWER

ENGINEERING DATA AND SPECIFICATIONS. Marley Aquatower FIBERGLASS CROSSFLOW COOLING TOWER ENGINEERING DATA AND SPECIFICATIONS Marley Aquatower FIBERGLASS CROSSFLOW COOLING TOWER Aquatower Fiberglass Cooling Tower Features and Benefitrs 2 Proven Performance. CTI Certified. Plus SPX stands by

More information

FAN SEPARATOR. Fan / Separator H2SO4 (Sulfuric Acid) is Designed to Remove Fume and Other Contaminants from the Air Stream.

FAN SEPARATOR. Fan / Separator H2SO4 (Sulfuric Acid) is Designed to Remove Fume and Other Contaminants from the Air Stream. FAN SEPARATOR Fan / Separator H2SO4 (Sulfuric Acid) is Designed to Remove Fume and Other Contaminants from the Air Stream. FAN / SEPARATOR SPECIFICATIONS Various materials of construction may be used to

More information

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw Air cooled chillers with brushless oil-free compressors R-134a RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw External installation with very low sound level Cooling circuit with

More information

SECTION COOLING TOWERS

SECTION COOLING TOWERS SECTION 23 65 00 COOLING TOWERS PART 1 - GENERAL 1.1 DESCRIPTION A. Packaged, induced draft open circuit cooling tower complete with fill, fan, inlet louvers and associated accessories and equipment. 1.2

More information

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER) SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER) SERIES: WCHZ MODELS: 201, 251, 271, 351, 401, 501, 701, 721, 751 COOLING CAPACITIES OF: 6,4

More information

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) www.blowtech.in we make air move Blowtech Air Devices Pvt. Ltd. was founded in 1988 and quickly established

More information

STORAGE ROLLER CABINETS & TOOL CHESTS...8 MODULES...12 FURNITURE SHOP...18 MAGNETIC ACCESSORIES...21 WORKSHOP TROLLEYS...22 METAL CHESTS...

STORAGE ROLLER CABINETS & TOOL CHESTS...8 MODULES...12 FURNITURE SHOP...18 MAGNETIC ACCESSORIES...21 WORKSHOP TROLLEYS...22 METAL CHESTS... ROLLER CABINETS & TOOL CHESTS...8 MODULES...12 FURNITURE SHOP...18 MAGNETIC ACCESSORIES...21 WORKSHOP TROLLEYS...22 METAL CHESTS...23 TOOL BOXES & SOFT STORAGE...23 MULTI-TOOL SETS...25 www.britoolexpert.co.uk

More information

Centeral Station Air Handling Unit

Centeral Station Air Handling Unit Centeral Station Air Handling Unit CA Series www.windind.com www.windind.com The product range includes double skinned Air Handling Units, double skinned Fan Coil Units, and custom designed packaged roof

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be

More information

EHH SERIES DRAW THROUGH FAN COILS CFM

EHH SERIES DRAW THROUGH FAN COILS CFM EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE

More information

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9 ERV/ HRV CONTENTS Horizontal rotor heat recovery ventilation unit RH 5 Vertical rotor heat recovery ventilation unit RV 9 Suspended plate heat recovery ventilation unit CFP Horizontal plate heat recovery

More information

39G Air Handling Unit

39G Air Handling Unit 39G Air Handling Unit Air flow: 2000 ~ 60000 m³/h The Manufacturer reserves the right to change any produt specifications without prior notices Version: Supersede: Effective Date: CAT_39G_E-1307_02 CAT_39G_E-1205_01

More information

Michigan State University Construction Standards. COOLING TOWERS Page SECTION COOLING TOWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Michigan State University Construction Standards. COOLING TOWERS Page SECTION COOLING TOWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS Page 236500-1 SECTION 236500 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

LED New Light Source Reflow Oven. Model: T-960

LED New Light Source Reflow Oven. Model: T-960 LED New Light Source Reflow Oven Model: T-960 Features: 1. This machine selects the intelligent level sirocco and rapid infrared heating technology controlling, equipped with special design wind wheel,

More information

Series 5000 Industrial Modular Cooling Tower. Series 5000 Cooling Tower. engineering Data

Series 5000 Industrial Modular Cooling Tower. Series 5000 Cooling Tower. engineering Data Series 5000 Industrial Modular Cooling Tower Table Of Contents B9 Series 5000 Cooling Tower B41 Structural Support B15 Construction Details B43 alternative Structural Support B17 Custom Features & Options

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans PARAG FANS & COOLING SYSTEMS LTD. Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans Registered Office & Works Plot No.1/2B & 1B/3A, Industrial Area No.1 A.B.Road, Dewas 455001 (M.P.)

More information

Aquatower STEEL COOLING TOWER. engineering data and specifications

Aquatower STEEL COOLING TOWER. engineering data and specifications Aquatower STEEL COOLING TOWER engineering data and specifications Aquatower Steel Cooling Tower Features and Benefits 2 Proven Performance. CTI Certified. Plus SPX stands by its responsibility for reliable

More information

AIR HANDLING UNITS MANDÍK

AIR HANDLING UNITS MANDÍK AIR HANDLING UNITS MANDÍK 2 CONTENTS MANDÍK, a. s. The Company... 3 Photo Gallery... 4 Unit Description... 6 Air handling unit parameters according to Eurovent... 7 Product Range of the Air Handling Units...

More information

VOLUME 2 (BOQ & Price Bid)

VOLUME 2 (BOQ & Price Bid) TENDER DOCUMENT NIT No: PAT/CON/721/01 FOR Tender for Supply, Erection & Commissioning of Refrigeration Plant for chilled water system for Ice-Cream mix section complete for 20 KLPD Ice Cream Plant at

More information

Double Skin Casing Air Handling Units

Double Skin Casing Air Handling Units Double Skin Casing Air Handling Units Double wall with 25 mm insulation Modular design for clean process application flexibility all the requirements 2,000 40,000 CFM AUTUMN Air Handling Units incorporate

More information

DRY BULK HANDLING SYSTEM

DRY BULK HANDLING SYSTEM DRY BULK HANDLING SYSTEM Parson Marine Equipment is established in Singapore since July 2005. Our team of engineers have more than 25 years of experiences in providing customised integrated dry and wet

More information

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING TM MITTAL ENGINEERING M i t t a l E n g i n e e r i n g i s o n e o f t h e l e a d i n g m a n u f a c t u r e r s q u a l i t y e n g i n e e r i n g

More information

Product Introduction...E35. Benefits...E37. Construction Details...E39. Custom Features & Options...E41. Accessories...E44. Engineering Data...

Product Introduction...E35. Benefits...E37. Construction Details...E39. Custom Features & Options...E41. Accessories...E44. Engineering Data... Series V Closed Circuit Cooling Towers Product Detail Closed Circuit Cooling Towers Product Introduction...................................E35 Benefits...............................................E37

More information

Deluge Valves. Model 68 DE\ EL. Electrically Actuated Remote-Reset Deluge Valve. Dorot Fire Protection Division. Certification & compliance by design

Deluge Valves. Model 68 DE\ EL. Electrically Actuated Remote-Reset Deluge Valve. Dorot Fire Protection Division. Certification & compliance by design Fire Protection Div. Dorot Fire Protection Division Deluge Valves Model 68 DE\ EL Electrically Actuated Remote-Reset Deluge Valve Certification & compliance by design 1 ANSI FCI 70-2 Class VI seat leakage

More information

BORS - Bilge Oil Removal Systems

BORS - Bilge Oil Removal Systems BORS - Bilge Oil Removal Systems MEPC 107 (49) Series OWS Specifications (at US Coast Guard 5 ppm Standard) BORS Model BORS-2.2T BORS-5T BORS-11T BORS-25T BORS-45T Height in/mm 48 / 1219.2 48 / 1219.2

More information

Efficient, Long Lasting Evaporative Condensers

Efficient, Long Lasting Evaporative Condensers CONDENSERS Efficient, Long Lasting Evaporative Condensers Reliable Products With Long-Term, Low Cost of Ownership CONDENSERS Specifications Standard Unit Construction Corrosion Protection (Coil & Casing)

More information

Layout. Guidelines11. Chapter 11: Layout Introduction

Layout. Guidelines11. Chapter 11: Layout Introduction Guidelines11 Chapter 11: Layout 37 Layout 1. Introduction Open circuit cooling towers, closed circuit cooling towers and evaporative condensers all depend upon an adequate supply of fresh, ambient air

More information

GRAVITY SCREEN FILTER

GRAVITY SCREEN FILTER IRRIGATION EQUIPMENT LTD. GRAVITY SCREEN FILTER SERIES 188 APPLICATIONS Gravity Flow Irrigation Systems Used as a Primary Filter for water from open reservoirs and recycled water. Pre-Filtration for media

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

Mini SMT Reflow Oven Model: T-961

Mini SMT Reflow Oven Model: T-961 Mini SMT Reflow Oven Model: T-961 Taian Puhui Electric Technology Co., Ltd http://www.tech168.cn Http://www.tech168.cn 1/13 Features: 1. This machine selects IR and hot air heating technology controlling,

More information

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42 SELF CONTAINED HORIZONTAL UNITS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER ) HEAT PUMP. WCHBZ COOLING ONLY. WCHZ SERIES: WCHBZ - Heat Pump MODELS: 201, 251, 271, 351, 401, 501 COOLING

More information

CONTENT ANHUI KOYO BEVERAGE MACHINERY CO LTD 安徽蓬源饮料机械有限公司 1.MACHINE EXPLAINATION 2 2.MACHINE MAIN STRUCTURE 2 3.MACHINE PARAMETER 8

CONTENT ANHUI KOYO BEVERAGE MACHINERY CO LTD 安徽蓬源饮料机械有限公司 1.MACHINE EXPLAINATION 2 2.MACHINE MAIN STRUCTURE 2 3.MACHINE PARAMETER 8 RFC8-8-3 INTEGRATED RINSING FILLING CAPPING MACHINE MANUAL BOOK CONTENT 1.MACHINE EXPLAINATION 2 2.MACHINE MAIN STRUCTURE 2 3.MACHINE PARAMETER 8 4.DIMENSION, WEIGHT 8 5.INSTALL AND ADJUST 9 6.OPERATION

More information

TOPAZ ADIABATIC COOLER

TOPAZ ADIABATIC COOLER TOPAZ ADIABATIC COOLER CONTENT Page Principle and operation 2 General description and benefits 3 TECHNICAL DOCUMENTATION Manufacturing details Options 4 6 Drawings and dimensions 7 On site lay out 8 Technical

More information

Lab 1b Cooling Tower Performance and Sensors for Thermal-Fluid Systems

Lab 1b Cooling Tower Performance and Sensors for Thermal-Fluid Systems Lab 1b Cooling Tower Performance and Sensors for Thermal-Fluid Systems OBJECTIVES Warning: though the experiment has educational objectives (to learn about boiling heat transfer, etc.), these should not

More information

Chocolate Cooling Tunnel

Chocolate Cooling Tunnel Chocolate Cooling Tunnel Instruction Manual AMC-CT600 AMC SYSTEM TECHNOLOGY USA, INC. 1. Equipment Application AMC cooling tunnel is mainly used for cooling food industry. Such as the chocolate,candy,biscuit,

More information

Maximum Capacity and Highest Quality to the. Lowest Shipping Costs! Engineered to Deliver the. Worldwide Market - with the.

Maximum Capacity and Highest Quality to the. Lowest Shipping Costs! Engineered to Deliver the. Worldwide Market - with the. Bulletin 167CH Engineered to Deliver the Maximum Capacity and Highest Quality to the Worldwide Market - with the Lowest Shipping Costs! International Institute of Ammonia Refrigeration Advanced Technology

More information

CLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements

CLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements Excellent quality / price ratio Very short delivery time Double wall 50 mm insulation Complete range meeting all the tertiary requirements Air flow : 000 to 7 000 m 3 /h DESCRIPTION Casing Double wall

More information

Chemistry diaphragm pumps

Chemistry diaphragm pumps Oil-free vacuum for corrosive gases and vapors Chemistry diaphragm pumps Series overview Examples of use Down to 70 Pumping of aggressive gases and vapors For low-boiling solvents Vacuum filtration Down

More information

Product Introduction...D33. Benefits...D35. Construction Details...D37. Custom Features & Options...D39. Accessories...D41. Engineering Data...

Product Introduction...D33. Benefits...D35. Construction Details...D37. Custom Features & Options...D39. Accessories...D41. Engineering Data... Series 1500 Product Detail Product Introduction..................................D33 Benefits...............................................D35 Construction Details...................................D37

More information

Equipment Information

Equipment Information VS96 Equipment Information INDEX: DESCRIPTION AND KEY FEATURES LAYOUT NOMINAL TECHNICAL DATA CONFIGURATION Sealed Air Ltd. Clifton House, 1 Marston Road St. Neots GB-Cambridgeshire PE19 2HN United Kingdom

More information