1 Data Sheet SS/ZFG_7 Zirconia Oxygen Probe ZFG Series Envirnomental Certification MCERTS SIRA Certificate MC9900 /00 Combustion monitoring control true wet measurement of excess oxygen in situ measurement Low cost of ownership fully site-serviceable probe 7 months cell warranty Versatile four insertion lengths: 0.4m (6in.),.0m (9in.),.5m (58in.) and m (78in.) flame trap for gas-fired boiler applications soot filter as standard fast response options SIRA ML9900 /00 SIRA Certificate N o ML9900 /00 Superior technology and quality from the world leader in oxygen measurement
2 ZFG Series SS/ZFG_7 Introduction The ZFG Flue Gas Oxygen Probe is one of the most advanced in the world. A simplified design makes all the component parts easily accessible and field serviceable. This innovative probe construction gives the ultimate system flexibility while retaining all the features, benefits and reliability of the previous generation. The in situ probe is inserted directly into the boiler smoke box, or flue duct, eliminating the need for high-maintenace costly sampling installations. Operating in the process temperature range of 0 to 600 C (68 to F) the system gives true wet analysis of net excess oxygen in combustion gases. The probes can be fitted with a flame trap to extend their use for measurement on gas-fired boilers. Installation and commissioning are particularly easy and the level of in-service maintenance is extremely low. Principle of Operation The detector cell is constructed from stabilized zirconia featuring integral platinum electrodes and is specific to oxygen. Air is supplied to the internal (reference) electrode to provide a constant partial pressure of oxygen while the measured gases are in contact with the outer electrode, producing a potential proportional to O concentration. The Probe The zirconia probes, constructed from 6 stainless steel, house a ceramic dust filter, flame trap, detector cell, cell heater and thermocouple. Wiring and reference-air tube between the electronics unit and the probe can be carried in a single flexible conduit up to 0m (66 ft.) in length. Standard options include dual conduit to separate signal/power cables and IP65 rated versions. For other non-standard options contact ABB. The standard probe insertion lengths are 0.4,.0,.5 and.0m (6, 9, 58 and 78 in.) and fixing to the duct or smoke box is by means of a drilled flange. Standoff fixings can be used to reduce the insertion length for smaller ducts. An alternative / in. screwed bush is also available for fixing the 0.4m (6 in.) probe to the duct or smoke box. A Deflector Plate can be fitted if excessive dust flows are experienced in the flue. All components of the probe are easily removable and can be replaced on-site without the use of special tools or bonding agents. Replacement of the zirconia oxygen sensor can be made without the need for recalibration of the electronics unit. A calibration gas inlet port is fitted to the probes to enable accuracy checks to be made without removal of the probes from their mountings. The site-replaceable zirconia cell carries a 7 month warranty. Where a faster response is necessary the probe can be supplied with a fast response cell adaptor that replaces the filter and flame arrester. Where the flame arresting capability is required, the fast response test gas line purge is interlocked with the burner flameout detection. Replacement of the filter and flame arrestor with a flow-through cell adaptor enables the use of the 0.4m (6 in.) probe as an extractive (dry) O analyzer system. Clamp Screw Ceramic Filter Probe Gas Flow Deflector Plate Deflector Plate fitted to ZFG Zirconia Oxygen Probe
3 ZFG Series SS/ZFG_7 Probe Construction Standard Cell Applications Industrial boilers gas, oil or pulverized fuel fired Utility power boilers oil, gas or pulverized fuel fired Thermocouple Leads Heater Zirconia Cell Porous Ceramic Filter Recovery boilers Hospital boilers Incinerators (low temperature) Thermocouple Water vapor measurement on paper machines, laminates and chipboard manufacture (with ZMT transmitter only) Reference Air Electrode Contact Flue Gas MCERTS approval MC9900 /00 (with ZDT transmitter) Electrode Lead Test Gas Tube Inner Electrode (Reference) Outer Electrode (Measuring) Flame Arrester Flow-through Cell Thermocouple Leads Heater Zirconia Cell /8 in. BSP Thermocouple Reference Air Electrode Electrode Inner Electrode Outer Electrode 'O' Fast Response Cell Thermocouple Leads Heater Zirconia Cell Thermocouple Reference Air Electrode Electrode Inner Electrode Outer Electrode
4 ZFG Series SS/ZFG_7 Specification Calibration (in situ) One point using clean air Two point using certified test gas and air Flue temperature 0 to 600 C (68 to F) Pressure Suitable for all normal positive or negative flue pressures Dimensions See Overall Dimentions on Page 6 Probe fixing Flange (or / in. NPT screwed fitting for ZFG 0.4m [6 in.]) Probe insertion 0.4,.0,.5 or.0m (6, 9, 58 or 78 in.) Flange options Note. The Flange types listed are NOT pressure retaining. 0.4m (6 in.)zfg Standard 6.0 ±0.4mm thick x 0.0 ±mm dia. 6 holes 7.mm dia. equispaced on 80.0 ±0.mm PCD.0,.5 and.0m (9, 58 and 78 in.) ZFG Standard.0 ±mm thick x 65.0 ±0.mm dia. 6 holes.5 ±0.5mm dia. equispaced on 40mm PCD Rosemount/Westinghouse Model equivalent 6.0 ±0.4mm thick x 7.0 ±mm dia. 4 holes 9.5 (0.75 in.) dia. equispaced on 99.0 ±0.mm PCD ANSI B 6.5 (in.) 50lb.0 ±mm thick x 85.0 ±0.5mm dia. 4 holes 8mm dia. equispaced on 45.0 ±0.mm PCD DIN 50 Part DN65 PN 6, 5 and 40.0 ±mm thick x 5 ±0.5mm dia. 4 holes 0.0 ±0.mm equispaced on.0 ±0.mm PCD JIS B 8 DN65 5K.0±mm thick x 55.0 ±0.5mm dia. 4 holes 5 equispaced on 0.0 ±0.mm PCD Cable length 6m, 0m, 5m and 0m (0,, 49 or 66 ft) fitted Maximum cable length between the probe and the electronics unit 00m (8 ft) using EXFG/094 signal cable and EXFG/095 power cables. Probe weight 0.4m (6 in.) 6kg (.lb) [including 6m (0 ft) cable].0m (9 in.) 0.8kg (.7lb) [including 6m (0 ft) cable].5m (58 in.).6kg (5.5lb) [including 6m (0 ft) cable].0m (78 in.).5kg (7.5lb) [including 6m (0 ft) cable] Measuring Range Response rate Standard cell < 40s to 6% of step change < minute to 90% of step change (typical) Fast response cell For typically <s to t90 the fast response adaptor must be used Reference gas Clean, oil-free air. Flow rate 50 to 000cc/minute Construction 6 stainless steel and ceramic Thermocouple NiCr/NiAl EN PE4 Type K Insertion length 0.4m,.0m,.5m or.0m (6 in., 9 in., 58 in., 78 in.) Protection class Meets requirements of NEMA 4X/IP65 Envirnomental data Storage -5 o C to 55 o C (- to o F) Up to 95% humidity (non condensing) 4
5 ZFG Series SS/ZFG_7 Flanges & Fittings (Dimensions in mm [in.]) Note. These flanges are NOT pressure retaining. Standard Mounting Flange 0.4m (6 in.) Probe ANSI Mounting Flange mates with ANSI B6.5 (in.) 50lb (All Probes) 6 holes on 80 (.5) p.c.d. 6 (0.5) 4 holes 0 (0.78) on (4.7) p.c.d. (0.47) 0 (.97) Dia. 5 (6) Standard Mounting Flange.0m,.5m &.0m (9 in., 58 in. & 78 in.) Probes JIS Mounting Flange mates with JIS B8 DN65 5K (All Probes) 6 holes.5 (0.5) on 40 (5.5) p.c.d. (0.47) 4 holes 5 (0.6) on 0 (5.) p.c.d. (0.47) 65 (6.5) 55 (6.) DIN Mounting Flange mates with DIN 50 Part DN65 PN 6, 5 and 40 (all Probes) Model Mounting Flange 0.4m (6 in.) Probe 4 holes 8 (0.7) on 45 (5.7) p.c.d (0.47) 4 holes 9.5 (0.7) on 99 (.9) p.c.d. 6 (0.5) 85 (7.8) 7 (5) 5
6 ZFG Series SS/ZFG_7 Mounting Plates Dimensions in mm (in.) Six M6 studs equispaced on 80 p.c.d. 7 Six M0 studs equispaced on 40 p.c.d m (6 in.) Probe 0.0,.5 and 0m (9, 58 and 78 in.) Probes Mounting plates for ABB standard flanges are available as codeable options. Please contact ABB for other options Overall Dimensions Dimensions in mm (in.) 50 (5.9) 90 (7.48) nom. 400 (5.74) 6 (.44) 6 (.44) dia. 5 (5.98) 0.4m (6 in.) Probe For Flange Dimensions see Page 5.0,.5 and.0m Models (9, 58 and 78 in.) 6 (.44) dia. 40 (6.4) nom. 000, 500 or 000 (9.7, or 78.74) 6
7 ZFG Series SS/ZFG_7 Ordering Information Zirconia Oxygen Probe ZFG X X X X X X X X X Insertion Length 0.4m (6 in.).0m (9 in.).5m (58 in.).0m (78 in.) Flange Type Standard DIN ANSI JIS Model Special Conduit E ntry Type 0mm (0.78 in. ) / in. NP T Quantity None One standard Two standard One IP65 Two IP65 Length None 6m (0 ft) 0m ( ft) Cell Standard cell Flow-through cell Fast response cell Flame Arrester None Flame arrester* Reference Air Internal External Mounting Plate Assembly None Standard (0.4m [6 in.] probes) Standard (long probes) / in. NPT (0.4m [6 in.] probe only *Available for Standard cell only. Ordering Example ZFG ZFG Zirconia Oxygen Probe Insertion length.0m (9 in.) Flange type standard Conduit entry type 0mm (0.78 in.) Number of conduits two Conduit length 6m (0 ft) Cell type standard Flame arrester fitted Reference air internal tubing (within conduit) Mounting plate standard (long probes) Transmitters For details of transmitters for use with the ZFG probe see data sheets SS/ZMT and SS/ZDT/FG
8 ZFG Series SS/ZFG_7 ABB has Sales & Customer Support expertise in over 00 countries worldwide The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in UK (.05) ABB 005 SS/ZFG Issue 6 ABB Limited Oldends Lane, Stonehouse Gloucestershire GL0 TA UK Tel: +44 (0) Fax: +44 (0) ABB Inc. Analytical Instruments 976 S. Virginia St. Ste., E Reno, Nevada 895 USA Tel: Fax:
Low Temperature Zirconia Oxygen Analyzer
Data Sheet SS/ZDT FG Issue 10 Low Temperature Zirconia Oxygen Analyzer ZDT FG Environmental certification MCERTS SIRA certificate MC99000 1/00 User-friendly language options selectable system alarms comprehensive
More informationAnalyze IT Zirconia Oxygen Analyzer for Small Boiler Applications
Data Sheet Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications Ideal for small gas/oil fired boilers Cost effective solution for OEM outlets with a quick return on end-user investment Continuous
More informationZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement
Data sheet High Temperature Zirconia Oxygen Analyzer Superior technology and quality from the world leader in oxygen measurement User-friendly language options selectable system analysis comprehensive
More informationOxygen Probes. Operating Instructions. ABB Process Analytics
ZFG Oxygen Probes Operating Instructions ABB Process Analytics ABB PROCESS ANALYTICS The Company ABB Process Analytics specializes in the engineering, manufacture, sale and support of high quality, highly
More informationElectromagnetic Flowmeters
Instruction Manual BOOK 2 Mechanical Installation IM/MMAMBK2_6 Electromagnetic Flowmeters MagMaster TM AquaMag ABB The Company We are an established world force in the design and manufacture of instrumentation
More informationSodium Monitor. Data Sheet SS/8036_5. Model Wide measuring range (0.01 gkg 1 to 10mgkg 1 ) covers all power station applications
Data Sheet Sodium Monitor Wide measuring range (0.01 gkg 1 to 10mgkg 1 ) covers all power station applications Full sample temperature compensation maximises measurement accuracy 'Pumpless' liquid handling
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT CONFORMITY CERTIFICATE This is to certify that the StackFlowMaster System Manufactured by: ABB Ltd Oldends Lane Stonehouse Gloucestershire GL10 3TA Has been assessed by Sira Certification Service
More informationHazardous Area Zirconia Oxygen Systems
Operating Instructions IM/EXGP-INT_7 Hazardous Area Zirconia Oxygen Systems Interface Electronics Unit ABB The Company We are an established world force in the design and manufacture of instrumentation
More informationEXFG Oxygen Analyzer System. Installation Guide. EXFG Probe. ABB Process Analytics
EXFG Oxygen Analyzer System Installation Guide EXFG Probe ABB Process Analytics ABB PROCESS ANALYTICS The Company ABB Process Analytics specializes in the engineering, manufacture, sale and support of
More informationInstallation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit
EXGP Oxygen Analyzer System (ATEX) Installation Guide Interface Electronics Unit DO NOT OPEN WHEN ENERGISED OR WHEN AN EXPLOSIVE GAS ABB The Company We are an established world force in the design and
More informationTransmitter OCX 4400 THE LATEST BREAKTHROUGH FOR COMBUSTION FLUE GAS ANALYSIS. Product Data Sheet PDS A01 February, 2001
OCX 4400 Product Data Sheet PDS 106-440.A01 February, 2001 Oxygen/Combustibles Transmitter Both oxygen and combustibles measurements in a single instrument Unique architecture - electronics mounted with
More informationinstrumentation Hydrogen Analyzer Systems Unrivaled safety and technical expertise from the market leader in hydrogen measurement
Hydrogen Analyzer Systems Unrivaled safety and technical expertise from the market leader in hydrogen measurement World leader in hydrogen analysis Triple range analyzers Fail-safe design Fully certified
More informationA New Standard of Excellence
A New Standard of Excellence PREVENTION IS SO EASY... LIVING THROUGH A DISASTER IS NOT The reliable identification of low combustion oxygen in a fired heater or boiler has always been critical to the effectiveness
More informationZirconia Oxygen Analyzer
Installation and Operating Guide IM/ZDT/FG_6 Zirconia Oxygen Analyzer Low Temperature Version ZDT FG Series ABB The Company We are an established world force in the design and manufacture of instrumentation
More informationZircomat Oxygen Analyzers
Zircomat Oxygen Analyzers Finally Hassle Free Stack Gas Oxygen Measurement Many of the top fortune 500 companies have already discovered that installing a ZIRCOMAT Oxygen analyzer is the smart way to measure
More informationEndura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer
Operating instruction OI/AZ40 EN Rev. B Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer Measurement made easy Introduction The Endura AZ40 extends the range of combustion gas analyzers
More informationcontinuous emissions monitoring Combustion & Environmental Monitoring
continuous emissions monitoring Combustion & Environmental Monitoring Advanced CEM technology for accurate measurement and high reliability - to meet today s regulatory requirements and ready for future
More informationZirconia Oxygen Analyzer
User Guide IM/ZDT/GP_5 Zirconia Oxygen Analyzer High Temperature Version ZDT GP Series ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial
More informationModels 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers
Data sheet USP Conductivity Analyzers A conductivity system designed to meet USP for the Pharmaceutical Industry incorporating automatic Stage 1 test Meets USP requirements ensures compliance
More informationTHE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS
THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS A Worldwide Manufacturer of Process Analyzers and Instrumentation RELIABILITY EXPERIENCE SOLUTIONS AMETEK Process Instruments is a worldwide
More informationAutocalibration Systems for In Situ Oxygen Analyzers
Product Data Sheet CMB_PDS_340AC_AutoCal Autocalibration Systems for In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging from one to four oxygen analyzers Can be easily
More informationSuperOX TM Oxygen Sensor U.S. Patent No. 5,635,044
SuperOX TM Oxygen Sensor U.S. Patent No. 5,635,044 Operations Manual Super Systems Inc. 7205 Edington Drive Cincinnati, OH 45249 513-772-0060 800-666-4330 Fax: 513-772-9466 www.supersystems.com Table of
More informationDurafet II and Meredian II Combination ph/orp Electrodes for Honeywell 7777 Mountings Series 7777 Specifications
Durafet II and Meredian II Combination ph/orp Electrodes for Honeywell 7777 Mountings Series 7777 Specifications 70-82-03-06 July 2004 Overview Honeywell s 7777 Series of electrode mountings enables an
More informationMULTIPLEX SELF RECUPERATIVE gas burner
Installation - Maintenance MULTIPLEX SELF RECUPERATIVE gas burner SERIES MPSR The Nu-way Multiplex Recuperative System offers the alternative of a self-recuperative burner or a separate recuperator and
More informationDew-Point Transmitters and Instruments
Dew-Point Transmitters and Instruments Reliable moisture measurement for critical process control Moisture Measurement and Analysis Michell Instruments sensors provide accurate and reliable moisture measurement
More informationNO NO 2 NO x SO 2 CO CO 2 O 2
continuous emissions monitoring NO NO 2 NO x SO 2 CO CO 2 O 2 Combustion & Environmental Monitoring An Company Advanced CEM technology for accurate measurement and high reliability - to meet today s regulatory
More informationOxygen Sensing Solutions
Oxy020608 Issue H Oxygen Sensor Catalogue SST SENSING LTD Oxygen Sensing Solutions 1 Oxygen Sensing SST Sensing are experts in the field of oxygen and fluid measurement. We have a comprehensive range of
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT CONFORMITY CERTIFICATE This is to certify that the SITRANS F M MAGFLO MAG 5100W Electromagnetic Flowmeter with MAG 5000, MAG 6000 or MAG 6000 Industry Transmitter manufactured by: Siemens Flow
More informationAPPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview
Overview Modern combustion (or gas) turbine packages typically include an axial compressor, a combustion section and a turbine. Both compressor and turbine sections consist of one or more sets of fixed
More informationHFID Heated Total Hydrocarbon Analyzer Module
Product Data Sheet PDS 103-685.A01 October, 2003 NGA 2000 HFID Heated Total Hydrocarbon Analyzer Module Heated analyzer designed to operate from 200 F to 400 F Eliminates loss of hydrocarbons due to condensation
More informationThe A-series Eletta Flow Monitor with local indication and analog output
The A-series Eletta Flow Monitor with local indication and analog output GL series FA series GSS series FSS series The Pipe Section is constructed of copper alloy and fitted with BSP/NPT threads from 15
More informationCatalog. Self-operated Regulators Volume 2 Temperature Regulators
Catalog Self-operated Regulators Volume 2 Temperature Regulators Self-operated Regulators Temperature Regulators Volume 2 Catalog 2012 Overview Self-operated Temperature Regulators 5 Self-operated Pressure
More informationHeated Gas Sampling Probe PSG Basic
Heated Gas Sampling Probe PSG Basic Application The heated gas sampling probes series PSG Basic are used for continuous extractive gas analysis. They enable troublefree representative sampling of hot predominantly
More informationULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]
ULTIMA XL/XT Series Gas Monitors [ Ultimate Features Extreme Design ] Cost effective fixed installation gas monitors with HART Field Communications Protocol. Single-sensor units use catalytic, electrochemical
More informationSERIES 46000E Bi-Directional In-Line Deflagration Flame Arrester
SERIES 46000E Bi-Directional In-Line Deflagration Flame Arrester Suitable for use with Explosion Group IIB3 or IIA (NEC Groups C or D) Vapors PROTECTOSEAL CAUTION: If any questions arise concerning the
More information/8 DIN Level Indicator
Data Sheet SS/_6 High visibility 5-digit LED display clear and accurate indication Analog and relay outputs as standard high, low, latch and rate alarms, plus isolated retransmission Maths functions included
More informationHydrazine Analyzer Series 2171 Specifications
Hydrazine Analyzer Series 2171 Specifications 70-82-03-64 November 2009 Introduction The 2171 is the most advanced hydrazine instrument specifically developed for use in continuous measurement and determination
More informationDräger Polytron 5200 CAT Detection of flammable gases and vapours
Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion
More informationDELTA-TE III. Nozzle-mix line burner
4-21.7-1 DELTA-TE III Nozzle-mix line burner Combines excellent flexibility with extreme low emissions for direct firing Especially designed for firing in low oxygen, high humidity and/or inert process
More informationTypical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000
s AV(W)0500 AV(W) The domestic hot water boiler shall be a Camus ADVANTUS TM model having a recovery capacity of gph (lph) at 100ºF (56ºC) for DHW The domestic hot water boiler shall be design certified
More informationTypical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000
s AV(W)0500 AV(W) The domestic hot water boiler shall be a Camus ADVANTUS TM model having a recovery capacity of gph (lph) at 100ºF (56ºC) for DHW The domestic hot water boiler shall be design certified
More informationSBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING
SBI Single Burning Item - EN 13823 THE BENCHMARK IN FIRE TESTING FTT Single Burning Item (SBI) The importance of the SBI The European Construction Products Directive requires that all European Member states
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT CONFORMITY CERTIFICATE This is to certify that the SITRANS F M MAG 5100W Electromagnetic Flowmeter with MAG 5000, MAG 6000 or MAG 6000 Industry Transmitter DE-76181 Karlsruhe Germany manufactured
More informationBURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM
BURNERS/ FLARES VAREC BIOGAS 4W Series WASTE GAS BURNER & IGNITION SYSTEM The Varec Biogas 4W Series Waste Gas Burner is a highly reliable flare and ignition system ideal for use in burning excess biogas.
More informationABB. Measure IT Uvisor System Flame scanner for fuel oil and coal flame. UR600 IR Mod flame scanner Product Data Sheet (rev.
Flame scanner for fuel oil and coal flame (rev. A) Application: - Wall fired, corner fired and down-shot boilers - Oil, Orimulsion and pulverized coal burners PbS sensor to detect flame by infrared (IR)
More informationThank You for Attending Today s Webinar:
Detect, Measure, Analyze. Thank You for Attending Today s Webinar: Oxygen Measurement in Safety Critical Applications Your Host Jim Behnke Sales RAECO-LIC LLC jim@raeco.com Featured Speaker Sr Strategic
More informationProduct Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S
D10 is a type-approved measuring device which combines the advantages of the measuring principles transmittance and scattered light forward. Therefore, it is ideal for measurement of very low to high dust
More informationUsing the DewTrak II Dew Point/ Humidity Transmitter
APPLICATION NOTE 2016_FEB2 DT Rev 10 Using the DewTrak II Dew Point/ Humidity Transmitter The Model DewTrak ll Dew Point/Humidity Transmitter is a compact, cost effective, optical chilled mirror hygrometer.
More informationAFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh
WATER HEATERS / BOILERS COWB3 Oil-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 0654 March 08 Supersedes September 05 AFUE up to 85.% Heating Input 05,000 to 45,000 Btuh MODEL NUMBER IDENTIFICATION
More informationABB. Measure IT Uvisor System Dual sensor flame scanner. UR460 Mod. UVIR /ER/EF/DV Flame Scanner Product Data Sheet (rev B)
Dual sensor flame scanner (rev B) Application: - Wall fired and corner fired boilers - Gas, oil and coal multi-fuel burners Combined PbS IR sensor and high sensitivity UV tube Continuous self-checking
More informationSAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)
PART 1 - GENERAL A. RELATED DOCUMENTS SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu) Federal, State, and local requirements as applicable. Attached Permit Attached drawings B. SUMMARY 1. Provide
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT CONFORMITY CERTIFICATE This is to certify that the FIDAMAT 6 FID Analyser manufactured by: Siemens Production Automisation S.A.S. 1 Chemin de la Sandlach B.P. 189 F-67506 Haguenau Cedex France
More informationMFP14 Automatic pumps. for condensate and other industrial fluids
MFP1 Automatic pumps for condensate and other industrial fluids Effective condensate management... an essential part of any steam plant If energy requirements are to be kept to a minimum, then efficient
More informationINDITHERM. Low temperature gas burners
INDITHERM Low temperature gas burners 1-2.3-1 High turndown for maximum operation flexibility. Maximum capacities up to 1800 kw. Designed for firing in indirect fired processes. Excellent combustion throughout
More informationSIL 2. Ultima X Series Gas Monitors CERTIFIED
Ultima X Series Gas Monitors 5 Now with SIL 2 CERTIFIED Products Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection
More informationLevel Measurement Continuous level measurement Ultrasonic transmitters
Overview Configuration is a short-range integrated ultrasonic level transmitter. This intrinsically safe, 2 wire, 4 to 20 ma loop powered transmitter is ideal for liquids, slurries, and bulk materials
More informationSERIES 47K GAS SENSOR
Data Sheet SERIES 47K GAS SENSOR Remote Combustible Gas Detection Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com Series 47K Gas Sensor Remote Combustible Gas Detection MSA remote
More informationSULPHUR RECOVERY UNIT
19 October 2015 SULPHUR RECOVERY UNIT START-UP CONSIDERATIONS SHRIKANT KOLI BLACK & VEATCH, MUMBAI Agenda - Burner Management System - Control Loops - Refractory Dry-Out - Start-up Experiences 2 Burner
More information5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors
Ultima X Series Gas Monitors Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection methods. HART Protocol is now
More informationINFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY
INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY >OLYL >H]LSLUN[O 4H[[LYZ SMOKELESS FLARE MONITOR Smokeless Flare Monitor (FM) Smokeless flares incinerate flammable hazardous
More informationSmart Sensors and Analytical Instruments Honeywell Solutions for Analytical Measurement and Control
Industrial Measurement and Control Smart Sensors and Analytical Instruments Honeywell Solutions for Analytical Measurement and Control EASY TO INSTALL... EASY TO USE... EASY TO MAINTAIN... EASY TO OWN.
More informationGMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION
GMS-10 RVS Series Oxygen Sensors Accurate oxygen measurement DESCRIPTION The GMS-10 is a high-accuracy oxygen sensor suitable for many applications. Originally developed for boiler applications, the product
More informationXi Advanced Electronics for Zirconium Oxide Oxygen Probes
Xi Advanced Electronics for Zirconium Oxide Oxygen Probes Excellent accuracy Large backlit display and keypad NEMA 4X enclosure Works with Westinghouse/Rosemount, and most competitive ZrO probes HART communications
More informationOxymitter 5000 Hazardous Area Oxygen Transmitter
Oxymitter 5000 Hazardous Area Oxygen Transmitter http://www.raihome.com HIGHLIGHTS OF CHANGES Page General Summary Effective September 2006 Rev 2.0 Reformatted entire manual from a two column layout.
More informationCompact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments
VG07-018 Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments Mickey B. Frish, Richard T. Wainner, Matt C. Laderer Physical Sciences Inc. Andover, MA
More informationRevitalize Building Mechanical Systems (4619)
SECTION 235216 FIRE-TUBE CONDENSING BOILERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More information4600 Series Operating Instructions. Models 4623 and 4628 Conductivity Transmitters To Meet United States Pharmacopœia (USP 23) Regulations
4600 Series Operating Instructions Models 46 and 468 Conductivity Transmitters To Meet United States Pharmacopœia (USP ) Regulations 4600 0.50 µs/cm 5 C A A 0. 50 µs/cm 5 C 4600 A A ABB AUTOMATION The
More informationExperience In Motion. SIHI LEMD Compact Liquid Ring Vacuum Pump
Experience In Motion SIHI LEMD Compact Liquid Ring Vacuum Pump Reduced lifecycle cost and increase reliability in industrial vacuum pump applications The SIHI LEMD range of close-coupled liquid ring vacuum
More informationDraft Controls. When to use a Draft Control
Draft s For proper operation and efficient fuel consumption in oil, gas and/or coal-fired heating appliances, draft must remain constant. When it is, combustion is more complete, fuels are utilized efficiently,
More informationFireye FLAME SCANNERS
UV7A4 SC-107 APRIL 3, 2013 Fireye SCANNERS UV7SC UV7R4 UV Non Self-Checking Scanner Models: UV7A4, UV7R4 UV Self-Check Scanner Model: UV7SC DESCRIPTION The non self-check UV7A4, UV7R4 and self-check UV7SC
More informationABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements
Specifications COMMANDER 150 Universal Process Indicator High visibility 6-digit LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement
More informationNumerical Standards Listing
ISA-RP2.1-1978 - Manometer Tables Numerical Standards Listing ANSI/ISA-5.1-1984 (R1992) - Instrumentation Symbols and Identification ANSI/ISA-5.2-1976 (R1992) - Binary Logic Diagrams for Process Operations
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT CONFORMITY CERTIFICATE This is to certify that the D-R 290 Opacity and Dust Concentration Monitor manufactured by: DURAG GmbH Kollaustraße 105 22453 Hamburg Germany has been assessed by Sira Certification
More informationMadhu Honap HONEYWELL THERMAL SOLUTIONS INTRODUCTION
Madhu Honap HONEYWELL THERMAL SOLUTIONS INTRODUCTION Honeywell, great positions in good industries Honeywell Thermal Solutions HTS EMEA 5 Honeywell Thermal Solutions Thermal Solutions Word leading brands
More informationXi Advanced Electronics for Zirconium Oxide Oxygen Probes
Xi Advanced Electronics for Zirconium Oxide Oxygen Probes Excellent accuracy Large backlit display and keypad NEMA 4X enclosure Works with Westinghouse/Rosemount, and most competitive ZrO 2 probes HART
More informationSitron s CF Line of Flow Switch Monitors
Sitron s CF Line of Flow Switch Monitors Models: CF 12AC CF 12DC CF 420 F 420 RCF 420 Introduction Sitron s versatile and intelligent line of Thermal Dispersion Flow Switch Monitors are compact switches,
More informationTitle: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection
Procedure No: SOP-020 Revision No: 1.0 (January 21, 2011) Page No.: 1 of 7 1. INTRODUCTION AND SCOPE To obtain timely data for the purpose of air quality assessment, air quality trend reporting, and to
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT CONFORMITY CERTIFICATE This is to certify that the 3000HM Flame Ionisation Detector 3010 & 3030 Portable Flame Ionisation Detector manufactured by: Signal Group Ltd 12 Doman Road Camberley Surrey,
More informationNumerical Standards Listing
ISA-RP2.1-1978 - Manometer Tables Numerical Standards Listing ISA-5.1-1984 (R1992) - Instrumentation Symbols and Identification (Formerly ANSI/ISA-5.1-1984 [R1992]) ISA-5.2-1976 (R1992) - Binary Logic
More informationSetra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions
Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions 1.0 GENERAL INFORMATION Every SRH humidity sensor product is tested and calibrated before
More informationIMR Environmental Equipment, Inc Central Ave. St. Petersburg, FL Phone:
6400 IMR Environmental Equipment, Inc. 3634 Central Ave. St. Petersburg, FL 33711 Phone: 727-328-2818 E-Mail: Info@imrusa.com www.imrusa.com Table of Contents I. Overview.... 3 II. Working Principle..
More informationZirconia Oxygen Gas Analyzers
Fuji Instrumentation & Control Fuji Electric s Direct Insertion Type Zirconia Oxygen Gas Analyzers ZIRCOMAT-P ZIRCOMAT-C Detctor No sampling device is required Compact and light
More informationAFUE 95% Heating Input 50,000 to 200,000 Btuh
PRODUCT SPECIFICATIONS WATER HEATERS / BOILERS GWM-IE Gas-Fired, Modulating, Condensing, Wall Hung Hot Water Boiler Bulletin No. 210650 March 2018 Supersedes December 2015 AFUE 95% Heating Input 50,000
More informationproduct Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners
product Information on oil, gas and dual fuel burners Industrial burners Industrial burners sizes to flexible and reliable Weishaupt Industrial Burners: Flexible and reliable For more than years, Weishaupt
More informationInstallation and Servicing Instructions. Alpha GasSaver GS-2
Installation and Servicing Instructions Alpha GS- Passive Flue Gas Heat Recovery Device (PFGHRD) for use with an Alpha Condensing Combination s IMPORTANT: Read these instructions BEFORE installing the
More informationCirculation Heaters Selection Guidelines
Selection Guidelines Selecting a Circulation Heater Application Factors Corrosion Policy Selecting the proper circulation heater component requires critical engineering judgement and careful evaluation
More informationDräger Polytron 5100 EC Detection of toxic gases and vapors
Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen. It uses a high performance
More informationOxygen Analyser. Model 1632
Oxygen Analyser Model April 00 CONTENTS SPECIFICATIONS... DESCRIPTION... INSTALLING & COMMISSIONING...9 OPERATOR FUNCTIONS... SETTING UP THE TRANSMITTER... MAINTENANCE...9 APPENDICES APPENDIX CONSTITUENT
More informationT-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh
PRODUCT SPECIFICATIONS GAS UNIT HEATERS / DUCT FURNACES TU T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ Bulletin No. 20402 November 207 Supersedes November 206
More informationModel IVSI Positive Pressure Venting Systems
C O M M E R C I A L A N D I N D U S T R I A L V E N T I N G Model IVSI Positive Pressure Venting Systems Ideal for discharging exhaust gases and fumes from boilers, heaters, ovens, engines, turbines and
More informationInstallation and Servicing Instructions. Alpha GasSaver GS-1
Installation and Servicing Instructions Alpha GS-1 Passive Flue Gas Heat Recovery Device (PFGHRD) for use with an Alpha CD Condensing IMPORTANT: Read these instructions BEFORE installing the boiler For
More informationSUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!
SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N 238-44219-00 (Replaces pg. 2 in instruction manual.) CONGRATULATIONS! You have just purchased one of the finest water heaters on
More informationFIELD DRAFT CONTROLS
INDEX TYPE M... 7-7 TYPE MG-1... 7-8 TYPE M+MG2... 7-9 TYPE RC... 7-6 INTRODUCTION... 7-2 7-5 Expert Service. Quality Products. Since 1960. www.eccosupply.ca 7-1 For proper operation and efficient fuel
More informationColumbia Boiler Company
EMG Series Boilers Available in Natural Gas & Propane Rev 12012 Columbia Boiler Company PO Box 1070 Pottstown, PA 19464 Tel (610) 473-8457 Fax (610) 367-6800 Website www.columbiaboiler.com Email cbcsales@ptd.net
More informationRK Combustible Gas Transmitter Operator s Manual
65-2400RK Combustible Gas Transmitter Operator s Manual Part Number: 71-0060RK Revision: C Released: 1/31/13 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating
More informationABB. Measure IT Uvisor System Flame scanner for gas and oil burners. UR450 Mod UV flame scanner Product Data Sheet (Rev. B)
Flame scanner for gas and oil burners (Rev. B) Application: - Wall fired boilers - Gas and oil burners High sensitive UV tube Continuous self-checking Rugged detector head for harsh environments: - Protection
More information99 Washington Street Melrose, MA Phone Toll Free Visit us at
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com EAGLE X: AT A GLANCE................................ LOWEST COST OF OWNERSHIP NO
More informationProducts and performance
Products and performance February 26, 2016 GfG Instrumentation overview of fixed system products Slide 1 GfG Instrumentation, Inc. 1194 Oak Valley Drive, Suite 20, Ann Arbor, Michigan 48108 Toll free (USA
More informationEAGLE 2X: C155KIT EAGLE 3X: C157KIT
EAGLE 2X: C155 C155 Analyzer Particle Filter Quick Start Guide Owners Manual EAGLE 3X: C157 C157 Analyzer Particle Filter Quick Start Guide Owners Manual EAGLE 2X: C155KIT C155 Analyzer EAGLE 3X: C157KIT
More informationFlame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660
Selectivity Adjustable by Means of - High Pass Frequency Filter - Gain - Threshold Different Adjustments for Different Conditions (e.g. According Fuel or Combustion Technology) Possible, to be Activated
More information