I.O.M. #116 7/10 INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE. Covers Models from 25 to 100 tons.

Size: px
Start display at page:

Download "I.O.M. #116 7/10 INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE. Covers Models from 25 to 100 tons."

Transcription

1 I.O.M. #6 7/0 INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE Covers Models from 25 to 00 tons. 525 East Stop 8 Road Greenwood, IN fa: Service Department fa: sales@advantageengineering.com

2 TABLE OF CONTENTS.0 GENERAL. Introduction 3.2 Efficiency 3.3 Safety 3.4 Miscellaneous 3.5 General Information 4.6 Water Treatment 5.7 Specifications 5.8 Cut Away Drawing 6.9 How It works 7.0 Typical System Drawing INSTALLATION 2. Inspection Location Process Connections Freeze Protection Stand Mounting Options OPERATIONS 3. Low Ambient Air Temperature Sequence of Operation Medium Ambient Air Temperature Sequence of Operation High Ambient Air Temperature Sequence of Operation Components MAINTENANCE 4. Recommended Operation & Maintenance Schedule Fan Motor Relubrication Intervals Fa: Service Department Fa: Page: 2

3 . INTRODUCTION A. This manual covers fluid coolers from tons. B. When calling for assistance from the Manufacturer s Service Department, it is important to know the model and serial number of the particular unit. The model number contains critical unit information which is helpful for troubleshooting and operating difficulties. The serial number allows the service team to locate manufacturing and testing records which can have additional information relating to a particular unit..2 EFFICIENCY A. Long term efficiency is determined by proper maintenance of the mechanical parts of the unit and the water quality. B. The Manufacturer recommends filtering where required to prevent solids from plugging critical parts (pumps, heaters, seals for eample). C. The Manufacturer highly recommends that the owner obtain the services of a competent water treatment specialist and his recommendations followed. The Manufacturer accepts no responsibility for inefficient operation, or damage caused by foreign materials or failure to use adequate water treatment..3 SAFETY A. It is important to become thoroughly familiar with this manual and the operating characteristics of the unit. B. It is the owner s responsibility to assure proper operator training, installation, operation, and maintenance of the unit. C. Observe all warning and safety placards applied to the chiller. Failure to observe all warnings can result in serious injury or death to the operator and severe mechanical damage to the unit..4 MISCELLANEOUS A. The ability of the unit to maintain process temperature control is significantly affected by the method of installation as outlined in section 2 of this manual. B. If the operator has questions concerning the installation, operation or maintenance of the unit, contact the Manufacturer s Service Department Fa: Service Department Fa: Page: 3

4 .5 GENERAL INFORMATION A. The fluid cooler is a heat echanger that uses outdoor ambient air in conjunction with an evaporative water assist system to cool process water. B. The fluid cooler is self contained, meaning it has all the necessary controls and components to operate. C. The user must supply:. Pump tank station with piping to and from the unit. 2. City or well make-up water piping to the evaporation systems. 3. Compressed air piping to the process circuit. 4. Drain piping for the purge valve. 5. Main power electrical drop. D. The dry air cooling system will run anytime there is process water flow to the air coils.. Water flow is sensed by the onboard flow switch located on the inlet manifold to the air coils water circuit. 2. The fan will start and pull air across the coils. The fan speed is controlled by a motor drive that will adjust the RPM based on the process water eit temperature. The higher the temperature, the faster the fan will run. The RPM range is approimately 700 min ma. The motor drive will also soft start the fan motor. E. The evaporation system is a cooling assist to the main dry air cooling system that runs during periods of high ambient air temperatures. After the flow switch is made (indicating the fluid cooler pump is running and cooling is required), and the fan is running, and the outdoor air temperature is 75 or higher, the evaporation system will automatically start and run. F. The evaporation system operates by pumping the sump water up to dual water distribution troughs and dripping the water over the top of special treated cellulose evaporative media. The water saturates and runs by gravity down the media and drains back to the sump to be recirculated. Some of this water will evaporate while on the elements and will cool the air stream going into the air coils Fa: Service Department Fa: Page: 4

5 G. Other information:.6 WATER TREATMENT. The factory Leaving Water Temperature (LWT) set point is 80 F. LWT can be a adjusted lower if required by resetting the motor drive RPM. This will derate the fluid cooler s performance. A. The use of untreated or improperly treated water in a fluid cooler may result in scaling, erosion, corrosion, algae or slime. B. It is recommended that the services of a qualified water treatment specialist be engaged to determine what water treatment is required. C. Advantage assumes no responsibility for equipment failures which result from untreated or improperly treated water..7 SPECIFICATIONS MODEL HFC-25 HFC-50 HFC-75 HFC-00 GENERAL Capacity Tons Flow Rate GPM Design Water Temperature (F) FANS Quantity Horsepower: per motor Amps: per 460/3/ Amps: total 460/3/ CONNECTIONS 3 (inches) Process Water Inlet Process Water Outlet Compressed Air /2 /2 /2 /2 Adiabatic Water Supply /2 /2 /2 /2 Adiabatic Water Drain DIMENSIONS 3 (inches) Height 96 /2 04 /2 04 /2 04 /2 Length Depth 54 /2 54 /2 54 /2 54 /2 WEIGHTS 3 (pounds) Dry,300 3,600 5,400 7,200 Wet 2,200 5,400 8,00 0,800 Shipping,450 3,900 5,850 7,800 Notes. Cooling water from 95 F to 85 F with 73 F entering air prior to the cooling cool. Your Advantage representative can provide specific weather data for your area predicting typical operating conditions and water evaporation rates. Glycol/water is recommended for set point temperatures below 50 F and ambients below 40 F. 2. For 230/3/60 amps multiply by 2. For 575/3/60 amps multiply by Not for construction. Confirm dimensions and weights with Advantage prior to construction Fa: Service Department Fa: Page: 5

6 .8 CUT AWAY DRAWING Air Outlet Shown in adiabatic pre-cooling mode with side panel, wetted media and fan cover removed. Fan Pre-Cooling system water distribution trough (shown with top covers removed) Compressed air connection and solenoid valve to assist coil drain Process Fluid Outlet Evaporative Media Air Inlet Process Fluid Cooling Coils are kept dry to minimize contamination Sump Pump circulates water to wet evaporative media Process Fluid Inlet Sump Drain Valve For Pre-Cooling System Make-Up Valve for adiabatic pre-cooling system Fa: Service Department Fa: Page: 6

7 .9 HOW IT WORKS A. Warm process fluid is circulated through the closed loop cooling coil of the Hydra Hybrid Cooler. Cool ambient air is drawn across the coil by the unit s high efficiency direct drive fan/motor assembly drawing heat out of the process fluid and rejecting it to the surrounding air. B. The cooled process fluid is returned to the system reservoir to be circulated for process cooling. C. When the ambient temperature is slightly below the desired process fluid temperature, the Hydra Hybrid Cooler operates in the dry mode using no fluid. D. When the ambient temperature rises above the desired process fluid temperature, the Hydra Hybrid Cooler automatically switches to its adiabatic pre-cooling mode. E. The adiabatic pre-cooling mode uses water to wet an evaporative media installed in the air inlet prior to the cooling coil. When the warm ambient air is drawn across the media it evaporates some of the water cooling the air before it reaches the coil containing the process water. F. In the adiabatic mode the Hydra Hybrid Cooler can maintain fluid temperatures low enough to provide hydraulic and condenser cooling even at ambient temperatures above 95 F. G. When the ambient temperature drops the cooler automatically switches back to dry mode cooling to minimize water usage. H. When adiabatic pre-cooling is not required the sump is drained to minimize potential contamination. I. The unit is designed to be installed outside, elevated above an indoor reservoir so that the cooling coils and adiabatic sump drain by gravity when not in use. J. Each modular Hydra Hybrid Cooler includes a complete control system to optimize cooling and minimize water and electrical consumption. K. A custom computer program is available to predict normal maimum water temperatures and estimated annual water and electrical costs for your location Fa: Service Department Fa: Page: 7

8 .0 TYPICAL SYSTEM DRAWING Fa: Service Department Fa: Page: 8

9 2.0 INSTALLATION 2. INSPECTION A. A thorough inspection of the equipment, including all component parts and accessories, should be made immediately upon delivery. Any damage caused in transit, or missing parts, should be reported to the carrier at once. The consignee is responsible for making any claim for losses or damage. Electrical characteristics should also be checked at this time to ensure that they are correct. B. WARRANTIES. Please refer to the Limitation of Warrantys applicable to and in effect at the time of the sale/purchase of this product. C. SAFETY. Adequate precautions should be taken to safeguard the equipment and the premises from damage and the public from possible injury as appropriate for the installation and location of this product. 2.2 LOCATION A. Before handling and placing the unit into position a review of the most suitable location must be made. B. The product is designed for outdoor installation. A number of factors must be taken into consideration when selecting a location. Most important is the provision for a supply of ambient air to the product, and removal of heated air from the area. C. Higher fluid temperatures, decreased performance, and the possibility of equipment failure may result from inadequate air supply. D. Other considerations include:. Loading capacity of the roof or floor. 2. Distance to suitable electrical supply. 3. Accessibility for maintenance. 4. Local building codes. 5. Adjacent buildings relative to noise levels. 6. Location of drain for pre-cooling system. 7. Location of air and city water supply. 8. Location of indoor pump tank to allow gravity drain of coil. E. Fluid coolers must be located to insure an adequate supply of fresh air to the fans. When units are located adjacent to walls or in enclosures, care must be taken to ensure that the warm discharge air is not deflected and short-circuited back to the air intakes. F. Additionally, each fluid cooler should be located and positioned to prevent the introduction of discharge air into the ventilation systems of the building on which the fluid cooler is located and adjacent Fa: Service Department Fa: Page: 9

10 building. For detailed recommendations on fluid cooler layout, please consult with your service representative or the factory. G. Walls Or Obstructions. The air intake of the unit must be a minimum of 4 feet (.25 m) away from any wall or obstruction. Overhead obstructions are not permitted. If enclosed by three walls, the condenser must be installed as indicated for units in a pit. Non air intake side must have a minimum clearance of 2 feet (.65 M). Air In 4 ft (.25 m) minimum 2 ft (.65 m) minimum Air intake sides facing wall or obstruction Non Air intake sides facing wall or obstruction H. Multiple Units. A minimum of 8 feet (2.5 m) is required between multiple units placed side by side. If placed end to end, the minimum distance between units is 4 feet (.25 m). Air In Air In 8 ft (2.5 m) minimum Air intake sides facing another module require a minimum of 8 feet separation. 3 ft (.9 m) minimum When non air intake side face each other, a minimum of 3 feet is required between the units Fa: Service Department Fa: Page: 0

11 I. Units In Pits. The top of the unit must be level with or above the top of the pit. In addition, a minimum of 8 feet (2.5 m) is required between the unit and the pit walls. Air In 8 ft (2.5 m) minimum 8 ft (2.5 m) minimumm J. Louvers/Fence. Louvers and fences must have a minimum of 80% free area and 4 feet (.25 m) minimum clearance between the unit and lovers and or fence. Height of louvers or fences must not eceed top of the unit. Air In 4 ft (.25 m) minimum 4 ft (.25 m) minimum K. Hydra Fluid Coolers are large, heavy mechanical equipment and must be handled as such. A fully qualified and properly equipped crew with necessary rigging should be engaged to set the unit in position. Spreader bars must be used when lifting so that the lifting force must be applied vertically. Ensure the unit is placed in a level position. The unit should be securely anchored to the building structure, or concrete pad. The weight of the unit is not enough to hold in place during a strong wind, the legs must be anchored Fa: Service Department Fa: Page:

12 2.3 PROCESS CONNECTIONS Compress Air Supply Process Water Out Process Water In Adiabatic Pre-Cooling Water Supply Adiabatic Pre-Cooling System Drain Compressed Air Supply A. Process water connections:. Process water inlet. Slope the process water inlet supply towards the indoor pumping station to aid in process water draining. A 5% slope is recommended. 2. Process water outlet. Slope the process water outlet towards the indoor pumping station to aid in process water draining. A 5% slope is recommended. Terminate the return line above tank water level. Do not terminate the return water line below the holding level of the tank. B. Compressed Air:. A compressed air supply of about 5 30 psi (when engaged) is required to assist coil draining. 2. Compressed air must be dry to prevent freezing in cold climates. C. Adiabatic System Water Supply:. A supply of water is required for the adiabatic system for high ambient operation. 2. This water supply must be manually drained or other method of protection must be implemented when freezing may occur. D. Sump Purge Line:. The sump purge line must be connected to an open drain. Slope the purge line towards the open drain Fa: Service Department Fa: Page: 2

13 2.4 FREEZE PROTECTION A. This fluid cooler must be protected by mechanical and operational methods against damage and/or reduced effectiveness due to possible freeze-up. B. Please refer to the product catalog or contact your service representative or the factory for protection alternatives. C. Winter Operation. When operating the Hydra system in freezing weather, it is highly recommended that a glycol/water fluid be used to prevent coil damage from freezing. Coil freeze-up is not covered by the manufacturer s warranty. 2. Recommended concentrations for typical commercial glycol solutions: Ambient Temperature F Percentate of Glycol By Volume for Freeze Protection 8% Percentate of Glycol By Volume for Burst Protection 2% Freeze protection is required in systems where fluid must be pumped at the lowest anticipated temperature where no ice crystals are permitted. 4. Burst protection is adequate when the system will remain dormant during cold weather and where adequate space is available for some epansion caused by an ice/slush miture. 5. Confirm concentrations with your glycol supplier. Follow glycol manufacturers requirements for solution preparation Fa: Service Department Fa: Page: 3

14 2.5 STAND MOUNTING OPTIONS A. Most Hydra Fluid Coolers are elevated in some manner to provide the gravity induced return flow to the central system pump tank. B. The elevation is typically provided by a support structure, know as a stand. Shown here are several options to consider for stand earth mounting Fa: Service Department Fa: Page: 4

15 3.0 OPERATIONS 3. LOW AMBIENT AIR TEMPERATURE SEQUENCE OF OPERATION A. For ambient air temperatures of 45 F and below.. Power in On. 2. Process water pumped to the unit from a remote pump station. 3. Process water flow switch closes and signals the motor drive to start and run the fan to draw air over the coils. 4. Fan motor drive senses the eiting process water temperature from the coils and adjusts the fan RPM (700-50) in relation to the process water eiting temperature. 5. Process water flow stops (remote pump station set point temperature is satisfied), the unit flow switch will sense the loss of process water flow and signal the fan motor drive to stop the fan. 6. The PLC will energize the compressed air solenoid valve for one minute to allow air to enter the coil s upper manifold and push the water out of the process circuit and back to the pump station to prevent it from freezing inside the air coils. 7. Nothing further will happen until flow starts again. 3.2 MEDIUM AMBIENT AIR TEMPERATURE SEQUENCE OF OPERATION A. For ambient air temperatures of 46 F - 75 F.. Power in On. 2. Process water pumped to the unit from a remote pump station. 3. Process water flow switch closes and signals the motor drive to start and run the fan to draw air over the coils. 4. Fan motor drive senses the eiting process water temperature from the coils and adjusts the fan RPM (700-50) in relation to the process water eiting temperature. 5. Process water flow stops (remote pump station set point temperature is satisfied), the unit flow switch will sense the loss of process water flow and signal the fan motor to stop the fan. 6. Nothing further will happen until flow starts again. 3.3 HIGH AMBIENT AIR TEMPERATURE SEQUENCE OF OPERATION (ADIABATIC COOLING MODE) A. For ambient air temperatures of 75 F and above.. Power in On Fa: Service Department Fa: Page: 5

16 2. Process water pumped to the unit from a remote pump station. 3. Process water flow switch closes and signals the motor drive to start and run the fan to draw air over the coils. 4. Fan motor drive senses the eiting process water temperature from the coils and adjusts the fan RPM (700-50) in relation to the process water eiting temperature. 5. Sump water level switch signals the PLC that the sump is full or empty. 6. If sump is full, disregard the sequence If sump is empty, the sump water make-up valve opens and begins flushing (via the PVC flush pipe) any debris that may have collected in the dry sump out the open purge valve and into the user s drain. 8. Sump water purge valve closes after 30 seconds of debris flushing. 9. Sump water make-up solenoid continues sending water to the sump. 0. Sump level switch senses a full sump and closes the sump water make-up solenoid valve.. Sump pump starts and send sump water to the dual water distribution troughs. 2. Sump water drips out the bottom of the distribution troughs and onto the evaporative media. 3. Evaporative media becomes saturated with sump water and runs by gravity down the media and drains into the sump pan to be recirculated. 4. Ambient outdoor air is drawn through the media and evaporates some of the sump water and cools the air before it reaches the air coils. 5. Sump water make-up valve opens and closes to replace evaporated water to maintain proper sump level. 6. Process water flow stops (remote pump station set point temperature is satisfied) the unit flow switch will sense the loss of process water flow and signal the fan motor drive to stop the fan. 7. The sump pump will stop. 8. The sump water in the evaporative media will continue to drain back to the sump until the media is dry. 9. Nothing further will happen until flow from the remote pump station starts again, ecept that if the unit does not run for many hours the sump will automatically do a daily purge to maintain sump cleanliness. This daily purge will happen once every 24 hours. The Fa: Service Department Fa: Page: 6

17 sump will not refill after the daily purge if the ambient outdoor temperature has fallen below 75 F. 3.4 COMPONENTS A. Flow Switch. The flow switch senses process water flow into the air coils and provides consent to the control circuit to start and run the unit. B. Fan. The fan will move 20,000 RPM. RPM is controlled via the motor drive. The RPM range is The fan starts anytime process water flow is present. C. Air Coils. Dual air to water coils, rifled copper tube with aluminum fins. D. Compressed Air Solenoid. The air solenoid is controlled via the PLC. At ambient outdoor air temperatures of 45 F or less, the valve is opened to force drain the process water out of the air coil tubes after the pump station stops process water flow delivery to the unit. E. Compressed Air Check Valve. The check valve prevents process water from entering the compressed air supply piping. F. Sump Pan. The sump pan catches/holds un-evaporated water and foreign debris that has washed off the evaporative media. It also serves as a reservoir for the sump pump. G. Sump Purge Valve. Automatically empties the sump once every 24 hours to remove accumulated foreign debris and empties the sump when the ambient air temperature falls below 45 F. H. Level Switch. Monitors sump water level and activates the water make-up circuit. Also triggers an alarm when the sump level fails to fall during purge cycles. I. Sump Water Make-Up Solenoid. Supplies water to the sump for water make-up and to flush debris out of the sump pan during purge cycles via the PVC flush pipe. J. Sump Pump. Supplies sump water to the dual distribution troughs. K. Distribution Troughs. Dual troughs receive water from the sump pump and supply/drip water over the evaporative media, approimately 0 GPM to each side. L. Evaporative Media. Receives water from the distribution troughs and provides an absorbent area for maimum evaporation potential. Un-evaporated water drains from them into the sump pan Fa: Service Department Fa: Page: 7

18 M. Frame and Enclosure. Galvanized and stainless steel frame parts, sheet metal enclosure panels and ABS plastics fan shroud. N. Electrical System Enclosure. Concealed N-4 electrical cabinet with 4 4 main power junction bo. P. Control System. PLC and 24 vdc power supply Fa: Service Department Fa: Page: 8

19 4.0 MAINTENANCE 4. RECOMMENDED OPERATION AND MAINTENANCE SCHEDULE SERVICE Inspect general condition of unit Clean debris from unit Clean and flush sump Check and adjust sump water level Inspect heat transfer section Inspect wetted media Inspect wetter distribution trough Check operation of make-up valve Check unit for unusual noise or vibration Check motor voltage and current Lubricate fan motor bearings Check fan for rotation without obstruction Check fan and pump motor for proper rotation Drain sump and piping Check air solennoid operation Inspect protective finish Start Up Monthly 6 Months Winter Operation S 4.2 FAN MOTOR RELUBRICATION INTERVALS A. New motors having been in storage for over a year should be relubricated by the procedure noted below. The following relubrication intervals are suggested as a guide for long operating life. The Hydra HFC-25 uses a 5HP 25T frame fan motor. Hours of Service Per Year 5000 hrs Continuous Normal Application Seasonal Service Motor is idle for 6 or more months Continuous high ambients, dirty or moist locations, high vibration, or where shaft end is hot (pumps - fans) 5 HP - 25T Frame 5 yrs 2 yrs yr beginning of season 6 months B. LUBRICANT: Baldor motors are pre-greased normally with Shell Oil company s Dollum R. Several equivalent greases which are compatible with the Baldor furnished grease are Chevron Oil s SRI No.2 and Teaco Inc. Premium RD. C. PROCEDURE: Over greasing bearings can cause premature bearing failure. If motor is equipped with Alemite fitting, clean tip of fitting and apply gun. Use to 2 full strokes on motors in NEMA 25T frame. D. CAUTION: Keep grease clean. Lubricate at standstill. Remove and replace drain plugs at standstill. Do not mi petroleum grease and silicone grease in motor bearings Fa: Service Department Fa: Page: 9

20 END 200 RE /09

21 Fa: Service Department Fa: Page: 2

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR MODEL RH REMOTE HORIZONTAL AIR COOLED HEAT EXCHANGERS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR MODEL RH REMOTE HORIZONTAL AIR COOLED HEAT EXCHANGERS INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR MODEL RH REMOTE HORIZONTAL AIR COOLED HEAT EXCHANGERS 9845 South 57 th Street Franklin, WI 53132 Telephone: (414) 421-4666 Fax: (414) 421-0712 MODEL RH

More information

CH250 AND CH251 CHILLERS

CH250 AND CH251 CHILLERS CH250 AND CH251 CHILLERS Operator s & Installation Manual Release Date: April 19, 2004 Publication Number: 620914801 Revision Date: May 15, 2015 Revision: G Visit the Cornelius web site at www.cornelius.com

More information

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check

More information

RCF Closed Circuit Cooling Towers RCC Evaporative Condensers

RCF Closed Circuit Cooling Towers RCC Evaporative Condensers RCF RCC RCT RCF Closed Circuit Cooling Towers RCC Evaporative Condensers ASSEMBLY & RIGGING INSTRUCTIONS RCF Closed Circuit Cooling Towers and RCC Evaporative Condensers should be rigged and assembled

More information

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check

More information

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and

More information

Evaporative Cooling products

Evaporative Cooling products user manual Evaporative Cooling products OPERATION - MAINTENANCE Z0582995_A ISSUED 06/2017 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT general information Note Recold

More information

CHILLER. Operator s & Installation Manual

CHILLER. Operator s & Installation Manual CHILLER MODELS: CH1001-A Operator s & Installation Manual Release Date: August 9, 2002 Publication Number: 620914301 Revision Date: May 6, 2010 Revision: E Visit the IMI Cornelius web site at www.cornelius.com

More information

KCC Centrifugal Fan Air Cooled Condensers

KCC Centrifugal Fan Air Cooled Condensers PRODUCT DATA & INSTALLATION Bulletin K50-KCC-PDI-10 KCC Centrifugal Fan Air Cooled Condensers Air Cooled Models from 103 Thru 164 Four to ninety Ton 1064435 We are on the Internet www.keepriterefrigeration.com

More information

POWER TOWER SERIES Fiberglass Construction 45 to 540 Tons

POWER TOWER SERIES Fiberglass Construction 45 to 540 Tons Temperature Control Units Water & Oil 0-500 F Portable Chillers Air & Water-Cooled 0-70 F Central Chillers Air & Water-Cooled Packages & Modules 0-70 F Pump Tank Stations Chilled or Tower Water 00-00 gallons

More information

COLMAC COIL. Installation, Operation, and Maintenance ENG Rev A. Air Cooled Fluid Coolers. Contents. When you want Quality, specify COLMAC!

COLMAC COIL. Installation, Operation, and Maintenance ENG Rev A. Air Cooled Fluid Coolers. Contents. When you want Quality, specify COLMAC! COIL Manufacturing Inc. When you want Quality, specify COLMAC! Installation, Operation, and Maintenance ENG00018621 Rev A Air Cooled Fluid Coolers Contents 1. SAFETY INSTRUCTIONS... 1 2. MODEL NOMECLATURE...

More information

Maintain. a TOWER of POWER. Part One How to. Don t let out of site, out of mind prevent you from keeping cooling towers running efficiently

Maintain. a TOWER of POWER. Part One How to. Don t let out of site, out of mind prevent you from keeping cooling towers running efficiently Part One How to Maintain a TOWER of POWER Don t let out of site, out of mind prevent you from keeping cooling towers running efficiently BY GLENN A. BABCOCK The cooling tower is often the forgotten component

More information

PDF Created with deskpdf PDF Writer - Trial ::

PDF Created with deskpdf PDF Writer - Trial :: Instruction Manual Index Introduction Uncrating and Checking for Damage Locating Your Unit Installation Fill Tank Process Connections Pre Startup Startup Sequence Trouble Shooting Chart Operating Lights

More information

How about Savings in Time, Money, Energy and Longer Life?

How about Savings in Time, Money, Energy and Longer Life? Chapter 17: The Value of Maintaining Evaporative Cooling Equipment 97 The Value 17 of Maintaining Evaporative Cooling Equipment 1. Cooling Tower Maintenance and Upgrades... What s in it for You? How about

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

Guide To Troubleshooting INEFFICIENT COOLING FANS

Guide To Troubleshooting INEFFICIENT COOLING FANS Guide To Troubleshooting INEFFICIENT COOLING FANS TABLE OF CONTENTS Introduction Enclosure Cooling Basics Key Attributes of Enclosure Cooling Symptoms of Poor Enclosure Cooling Typical Cooling Fan Problems

More information

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

4201 Lien Rd Madison, WI Owner s Manual Therma-Stor III Heat Recovery System. Installation, Operation & Service Instructions

4201 Lien Rd Madison, WI Owner s Manual Therma-Stor III Heat Recovery System. Installation, Operation & Service Instructions 4201 Lien Rd Madison, WI 53704 TS-140F Revised 09-10 Owner s Manual Therma-Stor III Heat Recovery System Installation, Operation & Service Instructions Read and Save These Instructions Table Of Contents

More information

Installation, Operation, and Maintenance Information

Installation, Operation, and Maintenance Information Installation, Operation, and Maintenance Information Air Cooled Condensers 8-2016 Rev 0 Table of Contents General Safety Information 2 Inspection 2 Installation 2 6 Rigging and Assembly 2 Unit Location

More information

Water-Cooled Dual Compressor Screw Chiller

Water-Cooled Dual Compressor Screw Chiller Installation Manual IM 692-1 Group: Chiller Part Number: 629955 Effective: May 1997 Supersedes: IM663-1 IM683 IM692 Water-Cooled Dual Compressor Screw Chiller Installation Manual PFS 155C through PFS 210C,

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

Heat Exchanger Piping Hook-up

Heat Exchanger Piping Hook-up Heat Exchanger Piping Hook-up A Series B Series C Series SLE, SL & R Series EK, EKS & EKM Series K & KN Series U, UC & UR Series Note baffle location when inserting bundle into shell assembly after cleaning.

More information

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER 2001927 Prepared by: 860 Douglas Way PO Box 530 Natural Bridge Station, VA 24579 1 1.0 SCOPE: This

More information

Installation Operation Maintenance

Installation Operation Maintenance Installation Operation Maintenance Series R Air-Cooled Helical Rotary Liquid Chiller RTAD 085-180 (50Hz) Standard, Free Cooling and Heat Recovery models RTAD-SVX01F-E4 General information Foreword These

More information

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F Temperature Control Units Water & Oil - F Portable Chillers Air & Water-Cooled - 7 F Central Chillers Air & Water-Cooled Packages & Modules - 7 F Pump Tank Stations Chilled or Tower Water - gallons Cooling

More information

INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE

INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE I.O.M. #123 updated 03/28/2016 INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE Covering models From 5 to 40 tons With M1 Instruments & Scroll Compressors Model: Serial Number : 525 East Stop 18 Road

More information

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the bill

More information

TOPAZ ADIABATIC COOLER

TOPAZ ADIABATIC COOLER TOPAZ ADIABATIC COOLER CONTENT Page Principle and operation 2 General description and benefits 3 TECHNICAL DOCUMENTATION Manufacturing details Options 4 6 Drawings and dimensions 7 On site lay out 8 Technical

More information

PACKAGED AIR COOLED Product Data Catalog

PACKAGED AIR COOLED Product Data Catalog PACKAGED AIR COOLED Product Data Catalog MODELS ASP-10A ASP-15A ASP-20A ASP-00P ASP-00F ASP-00G A MEMBER OF MARDUK HOLDING COMPANY, LLC The Leader in Modular Chillers ETL and CSA Approved CHILLER MODULES

More information

CHILLER. Model CH3000. Operator s & Installation Manual

CHILLER. Model CH3000. Operator s & Installation Manual CHILLER Model CH3000 Operator s & Installation Manual Release Date: February 14, 2011 Publication Number: 620054173OPR Revision Date: May 08, 2014 Revision: B Visit the Cornelius web site at www.cornelius.com

More information

THERMAL SYSTEMS, INC. Installation and Operation Manual

THERMAL SYSTEMS, INC. Installation and Operation Manual THERMAL SYSTEMS, INC. Installation and Operation Manual Revised September 2016 1. GENERAL SAFETY INFORMATION 1.1 Specification Never exceed the maximum allowable temperature or pressure ratings. Never

More information

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW INSTALLATION INSTRUCTIONS RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW 92-106595-01-00 TABLE OF CONTENTS Introduction.......................................

More information

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the bill

More information

Condensing Unit Installation and Operating Instructions

Condensing Unit Installation and Operating Instructions Bulletin WCU_O&I 01 June 2003 Condensing Unit Installation and Operating Instructions WCU Air Cooled Condensing Unit Table of Contents Section 1. Section 2. Section 3. Section 4. Section 5. Section 6.

More information

Evaporative Cooling Equipment Installer / Contractor Pre Start-Up Checklist

Evaporative Cooling Equipment Installer / Contractor Pre Start-Up Checklist Evaporative Cooling Equipment Installer / Contractor Pre Start-Up Checklist CONTENTS 2 Safety and equipment precautions 4 Site information 4 pre Start-up Checklist The installer/contractor shall completely

More information

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs Q: How is the WSAC a closed-loop cooling system? A: The WSAC is a closed-loop cooling system because the process loop being cooled is inside the tube bundles

More information

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections. SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15410 - Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections. 1.02 SUBMITTALS A. Submit properly identified

More information

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers 60-500 Tons n Mission Critical Cooling n Central Plant Process Cooling n Specialized HVAC Cooling Systems COOLING SOLUTIONS

More information

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

SECTION SPLIT-SYSTEM AIR-CONDITIONERS SECTION 23 81 26 SPLIT-SYSTEM AIR-CONDITIONERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

More information

MAC-120HE-03 Air-Cooled Chiller

MAC-120HE-03 Air-Cooled Chiller MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03

More information

Direct Drive Fluid Coolers

Direct Drive Fluid Coolers H-IM-68 March 2000 Part No. 25001301 Replaces H-IM-44 Direct Drive Fluid Coolers Installation and Maintenance Data Table of Contents Inspection System Warranty Installation...2 Rigging Instructions...3

More information

Modular Supply Make-Up Air Unit

Modular Supply Make-Up Air Unit Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features

More information

Daikin Water Cooling, Heating, and High Capacity Booster Coils

Daikin Water Cooling, Heating, and High Capacity Booster Coils Installation and Maintenance Manual IM 900 Daikin Water Cooling, Heating, and High Capacity Booster Coils Group: Applied Air Part Number: IM 900 Date: February 2008 Types HI-F5, E-F5 2008 Daikin International

More information

Air-Handling System Cooling Options

Air-Handling System Cooling Options Air-Handling System Cooling Options High-Capacity, Economical Evaporative Cooling High-Efficiency, DX & CW Mechanical Cooling Pure and Simple Solutions AbsolutAire Air-Handling System Cooling Options Economical

More information

KCS-Line Air Cooled Condensers

KCS-Line Air Cooled Condensers PRODUCT DATA & INSTALLATION Bulletin K50-KCS-PDI-5 Part # 1085695 PRODUCT SUPPORT web: k-rp.com/kcs email: acc-fc@k-rp.com call: 1-844-893-3222 x526 scan: KCS-Line Air Cooled Condensers R407A R407C R448A

More information

SENTRA Series Water Unit

SENTRA Series Water Unit SENTRA Series Water Unit Standard Unit: F to 0 F Process Fluid Temperatures* Optional High Temperature Configuration to 0 F Direct Injection Cooling 0 to kw Heaters to 7. HP Centrifugal Pumps (0-00 GPM)

More information

SECTION AIR HANDLING UNIT

SECTION AIR HANDLING UNIT SECTION 15800 - AIR HANDLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE

INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE I.O.M. #058 1/03 INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE Covering Air-Cooled models from 5 to 30 tons with LE Instruments 525 East Stop 18 Road Greenwood, IN 46142 317-887-0729 fax: 317-881-1277

More information

User s Information and Installation Instructions

User s Information and Installation Instructions Outdoor Air Conditioner User s Information and Installation Instructions 13 SEER R-410A High Efficiency Split System These units have been designed and tested for capacity & efficiency in accordance with

More information

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER 2001829 OPERATIONS AND MAINTENANCE MANUAL Prepared by: 860 Douglas Way PO Box 530 Natural Bridge Station, VA 24579 1.0 SCOPE: This Operations and Maintenance

More information

HYBRID ADIABATIC Cooling System

HYBRID ADIABATIC Cooling System Blending Conveying Drying Process Cooling Heat Transfer Size Reduction HYBRID ADIABATIC Cooling System Water & Energy Savings Low Maintenance Improved Health & Safety Hybrid design combines dry cooler

More information

Energy-Saving Industrial Water Chillers

Energy-Saving Industrial Water Chillers Energy-Saving Industrial Water Chillers Cycling operation saves power Large storage reservoir Stainless steel pump Microprocessor controls MPC Industrial Water Chillers Motivair is a world-class supplier

More information

PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer

PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer 5/16 Rev. A 57-02509 2 Contents INTRODUCTION... 4 WARNING LABELS AND SAFETY INSTRUCTIONS... 5 PS SERIES PARALLEL

More information

Presenters. Brett Alexander. Mihir Kalyani. Troy Reineck

Presenters. Brett Alexander. Mihir Kalyani. Troy Reineck ow Brett Alexander Presenters Mihir Kalyani Troy Reineck Designing Your Water Treatment Program for Different Types of Heat Rejection Equipment Types of Heat Rejection Equipment Open Cooling Tower Closed

More information

User s Information and Installation Instructions

User s Information and Installation Instructions Outdoor Air Conditioner User s Information and Installation Instructions 10 SEER Standard Efficiency Split System These units have been designed and tested for capacity and efficiency in accordance with

More information

Surna 25-Ton Chiller Operating & Maintenance Manual

Surna 25-Ton Chiller Operating & Maintenance Manual www.surna.com 303.993.5271 Surna 25-Ton Chiller Operating & Maintenance Manual Models: 300F3-3. 300F4-3, 300FW-3 Revised: July 2015 Table of Contents Warranty Information 4 Limited Warranty 4 Limitation

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

Condensing Unit Installation and Operating Instructions

Condensing Unit Installation and Operating Instructions Bulletin ACU_O&I 02 August 2016 Condensing Unit Installation and Operating Instructions ACU Air Cooled Condensers Table of Contents Section 1. General Information... 2 Section 2. Refrigeration Piping...

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Installation, Operation and Maintenance Manual Packaged Chiller Models CC 6601, 6501, 6401, 6301, 6201, 6101 For Service, please contact Pfannenberg Service Company: U.S.A. Pfannenberg Inc. 68 Ward Road.

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

FOR YOUR SAFETY IMPORTANT WARNING. installation and service manual evaporative cooler model series H & O H76353A

FOR YOUR SAFETY IMPORTANT WARNING. installation and service manual evaporative cooler model series H & O H76353A 5H76353A May, 2010 installation and service manual evaporative cooler model series H & O c 9900100 us FOR YOUR SAFETY The use and storage of gasoline or other flammable vapors and liquids in open containers

More information

2003 METAL FORM MFG. FORM NO: PCIOM/03

2003 METAL FORM MFG. FORM NO: PCIOM/03 PRECOOLER PRE-CONDENSER EVAPORATIVE COOLERS Installation, Operation, and Maintenance Manual Energy Saver (ES) has a policy of continuous product improvement and reserves the right to change designs and

More information

INDOOR, SUSPENDED, STEAM OR HOT WATER HYDRONIC UNIT HEATER FOR VERTICAL OR HORIZONTAL CONFIGURATION

INDOOR, SUSPENDED, STEAM OR HOT WATER HYDRONIC UNIT HEATER FOR VERTICAL OR HORIZONTAL CONFIGURATION INDOOR, SUSPENDED, STEAM OR HOT WATER HYDRONIC UNIT HEATER FOR VERTICAL OR HORIZONTAL CONFIGURATION Contents MODEL WS... 2 STANDARD FEATURES... 2 TECHNICAL DATA... 3 DIMENSIONS... 3 ENGINEERING DATA...

More information

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES 60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,

More information

GeneSys Air-Cooled Screw Compressor Chiller

GeneSys Air-Cooled Screw Compressor Chiller Installation and Maintenance Manual IMM AGSB- Group: Chiller Part Number: 330412001 Date: October 2005 Supersedes: IMM AGS-1 GeneSys Air-Cooled Screw Compressor Chiller AGS 230B through AGS 475B Hertz

More information

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the bill of lading

More information

Installation, Operation and Maintenance Manual. TC Series. Centrifugal Chillers 60 to 180 Tons. Copyright 2009 Thermal Care

Installation, Operation and Maintenance Manual. TC Series. Centrifugal Chillers 60 to 180 Tons. Copyright 2009 Thermal Care Installation, Operation and Maintenance Manual TC Series Centrifugal Chillers 60 to 180 Tons Copyright 2009 Thermal Care Table of Contents FOREWORD...1 SAFETY GUIDELINES...1 GENERAL DATA...2 Table 1 Water

More information

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

TC-710 RECYCLING BALER

TC-710 RECYCLING BALER OPERATING AND MAINTENANCE INSTRUCTIONS TC-710 RECYCLING BALER READ INSTRUCTIONS THOROUGHLY BEFORE OPERATING 3451 S. 40th Street Phoenix, AZ 85040 602.437.5020 800.223.4540 www.tsissg.com info@tsissg.com

More information

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL H-Series & 203 THRU 223 SERIES ARROW PNEUMATICS, INC. REGENERATIVE DRYER DIVISION 2111 WEST 21ST STREET BROADVIEW, IL 60155 708-343-9595 708-343-1907

More information

INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE

INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE I.O.M. #075 updated 11/01/2016 INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE Covering models From 5 to 40 tons With CF Instruments & Scroll Compressors Model: Serial Number : 525 East Stop 18 Road

More information

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

Closed Circuit Cooling Towers

Closed Circuit Cooling Towers Closed Circuit Cooling Towers Overview Closed circuit cooling towers provide evaporative cooling for many types of systems, and the specific application will largely determine which BAC Closed Circuit

More information

1.1 This section applies to air handling units for HVAC Systems.

1.1 This section applies to air handling units for HVAC Systems. AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling

More information

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

SECTION SPLIT-SYSTEM AIR-CONDITIONERS SECTION 238126 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

Owner s Manual Therma-Stor II Heat Recovery System

Owner s Manual Therma-Stor II Heat Recovery System PO Box 8680 Madison, WI 53708 TS-138C Revised 8/08 Owner s Manual Therma-Stor II Heat Recovery System Installation, Operation & Service Instructions Read and Save These Instructions Table Of Contents 1.

More information

GRF Series Non-Cycling Refrigeration Dryers ANDARD ELECTRONIC DRAIN STANDARD ELEC SS EXPANSION VALVE F PRESSURE DEWPOINT

GRF Series Non-Cycling Refrigeration Dryers ANDARD ELECTRONIC DRAIN STANDARD ELEC SS EXPANSION VALVE F PRESSURE DEWPOINT ANDARD ELECTRONIC DRAIN 5 -YEAR WARRANTY STANDARD ELECTRONICC 5 -YEAR WARRANTY 35-39 F PRESSURE DEWPOIN SS EXPANSION VALVE STANDARD ELECTRONIC DRAIN 35-39 F PRESSURE DEWPOINT SS EXPANSION VALVE STANDARD

More information

Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ

Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ Operation & Maintenance Manual Table of Contents: 1.0 Introduction 1 2.0 Unpacking your COOL- SPACE 1 3.0 Set-up

More information

MH fluid cooler HYBRID DESIGN. HIGHER PERFORMANCE.

MH fluid cooler HYBRID DESIGN. HIGHER PERFORMANCE. MH fluid cooler HYBRID DESIGN. HIGHER PERFORMANCE. Hybrid Design. Utilizing a combination of evaporative fill media and prime surface coil(s), the MH Fluid Cooler offers significantly improved performance

More information

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions. Microchannel REMOTE AIR COOLED CONDENSER Technical Bulletin: MXCC_004_030817 Products that provide lasting solutions. Krack s new Microchannel Remote Air Cooled Condenser incorporates a new patented modular

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

Coil-In-Tank Design: Refrigeration System: Cabinet Construction: Rite-Temp Manufacturing pioneered the development of refrigerated industrial water chillers in 1948. Since the first Rite-Temp units were introduced, quality engineering and manufacturing has been a key

More information

SWIMMING POOL HEAT PUMP UNIT ECO - series. Installation & Instruction manual

SWIMMING POOL HEAT PUMP UNIT ECO - series. Installation & Instruction manual SWIMMING POOL HEAT PUMP UNIT ECO - series Installation & Instruction manual Rev. 1.00 28.11.2007 Contents SWIMMING POOL HEAT PUMP UNIT 1 CONTENTS 2 1. PREFACE 3 2. SPECIFICATIONS 4 2.1 Performance data

More information

CH750, CH751 & CH951 CHILLERS

CH750, CH751 & CH951 CHILLERS CH750, CH751 & CH951 CHILLERS Operator s & Installation Manual Release Date: April 19, 2002 Publication Number: 91256 Revision Date: March 25, 2014 Revision: F Visit the Cornelius web site at www.cornelius.com

More information

Technical Training Prodigy Undercounter Cubers. Models CU1526, CU2026 and CU3030

Technical Training Prodigy Undercounter Cubers. Models CU1526, CU2026 and CU3030 Technical Training Prodigy Undercounter Cubers Models CU1526, CU2026 and CU3030 List of Major Topics Introduction Installation Operation Maintenance Diagnosis Service Prodigy with a Bin 3 models CU1526

More information

MODEL # DF - - (W/CONTROLS) MODEL # AF - - (LESS CONTROLS)

MODEL # DF - - (W/CONTROLS) MODEL # AF - - (LESS CONTROLS) Vane Axial Fan MODEL # DF - - (W/CONTROLS) MODEL # AF - - (LESS CONTROLS) Owner's Manual MANUAL # PNEG-0-C 1 FAN CHECK LIST OK 1. All wire connections 2. Tip clearance on blade 3. Fan blade torqued to

More information

CHILLER MODEL: CH1500, 2000 AND 3000

CHILLER MODEL: CH1500, 2000 AND 3000 CHILLER MODEL: CH1500, 2000 AND 3000 Operator s & Installation Manual Release Date: February 12, 2010 Publication Number: 621055837OPR Revision Date: March 25, 2014 Revision: E Visit the Cornelius web

More information

Liebert Small System MCD and PFH Condensers (1-5 Ton) Warranty Inspection Check Sheet

Liebert Small System MCD and PFH Condensers (1-5 Ton) Warranty Inspection Check Sheet The following information must be fully completed and forwarded to your local Liebert sales office to establish your equipment warranty. Installer Address Owner Address Owner e-mail address Installation

More information

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models) Temperature Control Units Water & Oil - 00 F Portable Chillers Air & Water-Cooled 0-70 F Central Chillers Air & Water-Cooled Packages & Modules 0-70 F Pump Tank Stations Chilled or Tower Water 00-00 gallons

More information

MH Fluid Cooler HYBRID DESIGN. HIGHER PERFORMANCE.

MH Fluid Cooler HYBRID DESIGN. HIGHER PERFORMANCE. MH Fluid Cooler HYBRID DESIGN. HIGHER PERFORMANCE. Hybrid Design. Utilizing a combination of evaporative fill media and prime surface coil(s), the MH Fluid Cooler offers significantly improved performance

More information

ISOLATED DIRECT DRIVE PLENUM FAN (IDDP)

ISOLATED DIRECT DRIVE PLENUM FAN (IDDP) Our Expertise, Your Air-Moving Solution ISOLATED DIRECT DRIVE PLENUM FAN (IDDP) PART# 0601710001_rev_A INSTALLATION, OPERATION & MAINTENANCE MANUAL Please read and save these instructions for future reference.

More information

CTI Sponsored Educational Program

CTI Sponsored Educational Program Presented By: Kent Martens SPX Cooling Technologies, Inc. Slide No.: 1 CTI Mission Statement To advocate and promote the use of environmentally responsible Evaporative Heat Transfer Systems (EHTS) for

More information

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13 R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.

More information

Installation & Operation Manual Models: TSU

Installation & Operation Manual Models: TSU TSU-I-O Rev A Installation & Operation Manual Models: TSU 150-940 CAUTION: This appliance is not intended for potable water. This manual must only be used by a qualified heating installer / service technician.

More information

CHILLERS. Operator s & Installation Manual

CHILLERS. Operator s & Installation Manual CHILLERS MODELS: CH750, CH751 & CH951 Operator s & Installation Manual Release Date: April 19, 2002 Publication Number: 91256 Revision Date: May 5, 2010 Revision: D Visit the IMI Cornelius web site at

More information

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC. WYETH-AYERST CANADA INC. 1025, BOUL. MARCEL-LAURIN S T - L A U R E N T, Q U É B E C INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER MODEL P448800LT--55WC--22C66S Prepared par Claude Gadoury, P.

More information