1 APPICATINS Heating, ventilation, cooling, heat recovery >> FACTRIES >> commercial premises >> WAREHUSES >> HAS >> SPRTS & EISURE >> PACES F WRSHIP >> RESTAURANTS PREEVA air handling unit
2 PREEVA Series GAS FIRED HEATING, VENTIATIN AND CING UNITS Introduction The Reznor PREEVA is a new generation of gas fired air heaters to provide combined heating and ventilation with optional cooling. The units are available as either indoor or outdoor models with a wide range of heat outputs and cooling capacities. The units are available as non-condensing heaters with thermal efficiencies above 91% or fully condensing heaters with thermal efficiencies of 102% (ncv). PREEVA units have been developed utilising the proven engineering expertise gained by Reznor, with over 125 years experience of gas appliance manufacture. The design combines high thermal efficiency, quality components and ease of maintenance for enhanced life expectancy and reduced life cycle costs. The new range provides higher thermal efficiencies and reduced emissions with the addition of optional cooling and improved air filtration. To reduce on site installation time, units are supplied to site pre-assembled on a heavy gauge galvanised base and are fully wired complete with all motor starters. Where site access is restricted, the units can also be supplied (at additional cost) in sections for on site assembly. Features PREEVA gas-fired units incorporate patented 4-pass heat exchanger technology for optimum efficiency and enhanced life expectancy SHH and RHH models also incorporate a patented MacroChannel heat exchanger to provide 8-pass heat exchanger design with full load efficiency of 102% Choice of titanium stabilised aluminised steel or stainless steel heat exchangers to suit application Single burner with multi-try ignition provides enhanced reliability Patented self-aligning burner eliminates possible flame impingement and premature heat exchanger failure Quality and Standards CE EN1020 IS 9001 Model Range PREEVA units are available as indoor models (SDH / SHH) or outdoor weatherproof models (RDH / RHH) suitable for rooftop or low level installation. 7 non-condensing models with heat output ranging from 24-97kW 3 fully condensing models with heat output ranging from 54-99kW Cooling 18-65kW Air volumes External static pressure up to 400Pa Heat recovery unit SHH Gas fired condensing unit 102% Thermal Efficiency SDH Standard efficiency unit
3 Air Distribution The units are ideal for ducted installations with a choice of motor size and drives to provide external static pressures up to 400 Pascal (dependent on options fitted). An adjustable pulley is fitted to the motor to simplify on site airflow adjustment for final balancing. The units may also be used for free-blowing applications with a choice of optional outlet louvres, induction nozzles and 30 or 60 downflow heads. Units may also be supplied with purpose designed air distribution systems. PVC ducts ne of the possibilities are perforated PVC ducts. Quick, cost saving installation Available in many colours Evenly diffused air distribution without draughts ow noise Air Distribution Nozzles For large open areas, air induction nozzles provide even air distribution with automatic high level air recirculation. The nozzles are capable of an air throw of up to 60 metres and the high volume turnover induced eliminates the requirement to install additional high level recirculation fans. Nozzles may be grouped on a distribution plenum to provide controlled terminal velocities on both heating and cooling modes or may be supplied complete with mounting plates for fitting to conventional grille shoes. The rubber nozzles provide excellent acoustic reduction at high outlet velocities and may be adjusted through 60 for controlled air direction. ption: PREEVA Hybrid model PREEVA Hybrid models have a body and blowers that are oversized compared to the gas fired heat exchanger, so that they provide the same heating capacity but at a higher air flow. The advantages are: Reduced stratification by increased air throw and improved induction rate, as well as by a lower gradient between the supplied air and the ambient air Free-blowing units can be installed at a greater height Perfectly suited for PVC ducts and plenums with nozzles AIRFW Service Access All motor and burner controls are accessed from a single side. Units can be supplied with the controls access on either the right hand or left hand side, this must be clearly specified at order stage and cannot be changed once the units are manufactured. AIRFW eft hand access Ri h h Right hand access d AIRFW AIRFW Ri h h d
4 PREEVA Series GAS FIRED HEATING, VENTIATIN AND CING UNITS SDH and SHH Indoor Models Chassis and body Units are supplied factory assembled on a galvanised frame. Standard units are supplied with powder coat finish RA 9010 (white). ther colours available on request. All service access panels are hinged for ease of access with lift off hinges allowing for access where space is restricted. ptional insulation provides thermal and acoustic insulation. Heat exchanger Patented 4-pass vertical heat exchanger provides high thermal efficiency combined with extended life expectancy. Integral condensate drain between third and fourth pass removes the risk of condensate build up when units operate on fresh air during winter periods. SHH model consists of the above heat exchanger with aluminium MacroChannel section to provide increased thermal efficiency up to 102% (ncv). Burner Single burner with multi-try ignition provides enhanced reliability. Patented self-aligning burner eliminates risk of flame impingement and premature heat exchanger failure. Burners may be specified for on/off, high/low or fully modulating control. A microprocessor burner control provides full safety monitoring. Flue Fan assisted flue with venter fan mounted on top of stainless steel collection chamber. For SHH units an epoxy coated aluminium venter fan is fitted. Balanced flue operation eliminates the requirement for additional plant room ventilation. The balanced flue terminal provides both the flue outlet and combustion air inlet and requires only a single building penetration. ptional balanced flue wall outlet or roof outlet terminals are available. Units are also CE certified for fan assisted flue installations where combustion air is drawn from within the heated space or ventilated plant room. standard heat exchanger of the SDH and RDH, also the primary heat exchanger of the SHH and RHH Air handling Belt driven DIDW forward curved fans, with a choice of single or three phase motors. Three phase motor 0.75kW and above are energy efficient class IE2. Fans are selected for low noise operation with external static pressure up to 400 Pa. Adjustable drive pulley allows for on-site system balancing. Mixing box Aluminium aerofoil section dampers with edge seals for precise control of fresh air and recirculation air. Damper actuators may be factory fitted and wired to provide occupancy ventilation or fresh air free cooling. A wide range of filters are available with optional manometer or pressure switch to provide dirty filter indication. ptional Cooling and Heat Pump DX or chilled water cooling coils may be added where comfort cooling is required. Heat pumps, which are always placed outdoors, can also be connected to the DX coil. They provide a supplement or even an alternative to gas fired heating, for example where gas fired heating is not suited, or simply where an application with both heating and cooling is required. Units without a gas fired section but with a DX coil + heat pump are available, as well as units with both a gas fired section and DX coil + heat pump. Contact Reznor for more information about PREEVA combined with heat pumps. Controls Units are fully wired complete with all motor starters, an optional external isolator may also be fitted. Unit electrical protection IP20. A wide variety of control options is available to provide fully integrated control.
5 RDH and RHH utdoor Models Chassis and body The RDH and RHH outdoor units are supplied fully weatherproof complete with galvanised base frame, integral gutters and integrated flue terminal. ptional roof curbs also available. Zinc plated pre-painted panels are insulated to provide thermal and acoustic insulation. All service access panels are hinged for ease of access with lift off hinges allowing for access where space is restricted. Heat exchanger Patented 4-pass vertical heat exchanger provides high thermal efficiency combined with extended life expectancy. Integral condensate drain between third and fourth pass removes the risk of condensate build up when units operate on fresh air during winter periods. RHH model consists of the above heat exchanger with aluminium MacroChannel section to provide increased thermal efficiency up to 102% (ncv). Burner Single burner with multi-try ignition provides enhanced reliability. Patented self-aligning burner eliminates risk of flame impingement and premature heat exchanger failure. Burners may be specified for on/off, high/low or fully modulating control. A microprocessor burner control provides full safety monitoring. Flue Fan assisted flue with venter fan mounted on top of stainless steel collection chamber. For RHH units an epoxy coated aluminium venter fan is fitted. A flue terminal is installed at the service side of the unit. Air handling An intake hood with water separator is available on RDH and RHH units. For the air inlet, belt driven DIDW forward curved fans, with a choice of single or three phase motors. Three phase motor 0.75kW and above are energy efficient class IE2. Fans are selected for low noise operation with external static pressure up to 400 Pa. Adjustable drive pulley allows for on-site system balancing. The RDH and RHH have a rear duct spigot or an optional cabinet with a bottom or top outlet. Mixing box Aluminium aerofoil section dampers with edge seals for precise control of fresh air and recirculation air. Damper actuators may be factory fitted and wired to provide occupancy ventilation or fresh air free cooling. A wide range of filters are available with optional manometer or pressure switch to provide dirty filter indication. ptional Cooling and Heat Pump DX or chilled water cooling coils may be added where comfort cooling is required. Heat pumps can also be connected to the DX coil. They provide a supplement or even an alternative to gas fired heating, for example where gas fired heating is not suited or simply where an application with both heating and cooling is required. Units without a gas fired section but with a DX coil + heat pump are available, as well as units with both a gas fired section and DX coil + heat pump. Contact Reznor for more information about PREEVA combined with heat pumps. The heat pump can be installed separately from the PREEVA, or together with the PREEVA on a customized base frame offered by Reznor. This combination is supplied fully wired, connected and tested, complete with pre-programmed controls. Contact Reznor for more information about PREEVA combined with heat pumps. Controls Units are fully wired complete with all motor starters, an optional external isolator may also be fitted. Unit electrical protection IPX4D. A wide variety of control options is available to provide fully integrated control. option: DX coil for cooling and/or heat pump option: intake hood with water separator option: downflow cabinet
6 PREEVA Heat Recovery GAS FIRED HEATING, VENTIATIN AND CING UNITS Introduction Heat recovery module is an option on the PREEVA units. The pre-insulated module contains a cross flow heat exchanger with an incorporated summer bypass and a return air fan. This cross flow heat exchanger is Eurovent certified. Filters of different qualities are available to filter the fresh air and the returned air. peration The fresh air, taken in by the PREEVA unit is preheated by return / exhaust air passing through the cross flow heat exchanger. In this way, less energy is needed to heat the ventilation air. The efficiency of the heat exchanger runs up from 52 to 68% according the application. Models RDH and RHH - HRS: outdoors installation, with standard heat recovery efficiency HRH: outdoors installation, with high heat recovery efficiency SDH and SHH - HRS: indoors installation, with standard heat recovery efficiency 9 o C 0 o C 11 o C HRH: indoors installation, with high heat recovery efficiency 30 o C 20 o C
7 AIRFW AIRFW AIRFW AIRFW Ri h h d AIRFW Ri h h d Ri h h d Flue Installation For internal applications the balanced flue terminal provides both the combustion air inlet and flue outlet from a single building penetration. The terminals are ordered separately from the heaters to suit either a wall outlet or roof outlet. Additional flue and combustion air pipes may be added, up to a maximum of nine metres of flue pipe, plus nine metres* of combustion air pipe. (This reduces by 1.5 metres for every 90 bend fitted). A differential pressure switch shuts down the unit in the event of inadequate combustion air, blocked flue or flue fan failure. To comply with CE approvals, balanced flue appliances must be used with the manufacturer s balanced flue system. Balanced flue roof outlet (type C32) Balanced flue wall outlet (type C12) eliminates expensive roof opening and flashing The units are also certified for fan assisted flue installations, where the combustion air is to be drawn from inside the building; an alternative wall or roof terminal is required for this application. Maximum flue length 14 metres (12 metres on model 100). Shown are flue types C32, C12 and C52. ther flue types are B22, C42, C62 and C82.** Combustion air through wall, flue outlet through the roof (C52) Heater positions and flue arrangements are indicative. For heater and flue clearances please refer to the manufacturer's guidelines. Separate combustion air and flue pipes (type C12) for applications where wall thickness exceeds maximum length shown in flue dimension table A *up to 7.5 metres for model 100 A D C E D G B ** Please check local installation norms. Some flue types may not be allowed in some countries such as C62 in Belgium. G F B FUE DIMENSINS (mm) Model Vertical concentric flue terminal Horizontal concentric flue terminal Ø100mm Ø130mm Ø100mm Ø130mm A B C n/a n/a D E n/a n/a F (maximum wall thickness) n/a n/a G
8 PREEVA Series: SDH and R GAS FIRED HEATING, VENTIATIN AND CING UNITS SDH Indoor Model 46 A G C E F M M H B N I J K 100 D Front View Side View Rear View 1. Combustion air inlet 2. Flue outlet 3. Electrical connections 4. Gas connections 5. Access door P Q Plan View DIMENSINS Model SDH25 SDH30 SDH35 SDH43 SDH55 SDH73 SDH100 A mm B mm C mm D mm E mm F mm G mm H mm I mm J mm K mm mm M mm N mm mm P mm Q mm Flue and combustion collars (1,2) mm Typical configuration shown above for SDH complete with mixing box. For alternative configurations please consult Reznor. Unit shown with left hand access, units can also be supplied right hand access. eft hand access or right hand access must be specified on ordering as this cannot be changed once the units are manufactured. All dimensions have a tolerance of +/- 3mm
9 DH RDH utoor Model C R A M M H B N J 100 D Front View Side View Rear View Q 1. Combustion air inlet 2. Flue outlet 3. Electrical connections 4. Gas connections 5. Access door P Plan View DIMENSINS Model RDH25 RDH30 RDH35 RDH43 RDH55 RDH73 RDH100 A mm B mm C mm D mm H mm I mm J mm K mm mm M mm N mm mm P mm Q mm R mm Typical configuration shown for RDH complete with inlet weatherhood. For alternative configurations please consult Reznor. Unit shown with left hand access, units can also be supplied right hand access. eft hand access or right hand access must be specified on ordering as this cannot be changed once the units are manufactured. All dimensions have a tolerance of +/- 3mm
10 PREEVA Series: SHH and R GAS FIRED HEATING, VENTIATIN AND CING UNITS SHH Indoor Model (Condensing heaters with optional filters and mixing dampers) A C 46 M M N H B G I 100 E J K D Front View Side View Rear View Q 1. Combustion air inlet 2. Flue outlet 3. Electrical connections 4. Gas connections 5. Access door 6. Condense Drain P Plan View DIMENSINS Model SHH55 SHH83 SHH102 A B C D E G H I J K M N P Q Flue and combustion collars (1,2) Typical configuration shown above for SHH complete with mixing box. For alternative configurations please consult Reznor. Unit shown with left hand access, units can also be supplied right hand access. eft hand access or right hand access must be specified on ordering as this cannot be changed once the units are manufactured. All dimensions have a tolerance of +/- 3mm
11 HH RHH utdoor Model 46 A C R M M N H B I J K D Front View Side View Rear View Q 1. Combustion air inlet 2. Flue outlet 3. Electrical connections 4. Gas connections 5. Access door 6. Condense Drain P Plan View DIMENSINS Model RHH55 RHH83 RHH102 A mm B mm C mm D mm H mm I mm J mm K mm mm M mm N mm mm P mm Q mm R mm Typical configuration shown for RHH complete with mixing box plus inlet weatherhood. For alternative configurations please consult Reznor. Unit shown with left hand access, units can also be supplied right hand access. eft hand access or right hand access must be specified on ordering as this cannot be changed once the units are manufactured. All dimensions have a tolerance of +/- 3mm
12 PREEVA Series SDH & RDH TECHNICA DATA Model SDH25 RDH25 SDH30 RDH30 SDH35 RDH35 SDH43 RDH43 SDH55 RDH55 SDH73 RDH73 SDH100 RDH100 Nominal heat output Minimum thermal efficiency (ncv) kw % Gas Consumption 1 Natural gas G20 Natural gas G25 Propane G31 Gas connection 2 kg/h Rc ¾ Airflow 15 o C 15 o C cooling capacity utput cooling capacity Maximum with DX Coil Maximum with cooling water coil kw kw Motor power Minimum Maximum m m Maximum external static pressure Pa 400 Electrical supply kw : 230/240V 1N - 50Hz kw : 380/400V 3N - 50Hz Net weight kg SHH & RHH TECHNICA DATA Model Nominal heat output Minimum thermal efficiency (ncv) Gas Consumption 1 Natural gas G20 Natural gas G25 Propane G31 Gas connection 2 Airflow 15 o C 15 o C cooling capacity utput cooling capacity Maximum with DX Coil Maximum with cooling water coil Motor power Minimum Maximum kw % kg/h Rc kw kw m m SHH55 RHH % SHH83 RHH % Maximum external static pressure Pa 400 SHH102 RHH % Electrical supply kw : 230/240V 1N - 50Hz kw : 380/400V 3N - 50Hz Net weight kg Natural gas G20 Calorific value kw/m3 GCV, inlet gas pressure maximum 50 mbar, minimum 17.5 mbar. Propane G31 Calorific value 14.0kW/kg GCV, inlet gas pressure maximum 50 mbar, minimum 37 mbar Document reference number: GB/REZ/010/ Not supply line size. J&M Sabbestraat 130/A000 B-8930 Menen Belgium Tel. +32(0) Fax. +32(0) reznor.europe@nordyne.com Company Standards and Services: All Reznor products are tested and approved to CE standards. Reznor Europe nv is assessed to IS 9001 Quality Assurance. Reznor offers a service to its customers; including budget schemes, on site technical support and a comprehensive after-sales package. Reznor reserves the right to change specifications without prior notice.
CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS
CI/SfB 56.83 X EnviroPak Series GAS FIRED HEATING, VENTIATIN AND CING UNITS EnviroPak Series GAS FIRED HEATING, VENTIATIN AND CING UNITS Introduction The Reznor EnviroPak is a new generation of gas fired
More informationPREEVA EC Gas Fired Heating, Ventilation & Cooling Units
... PREEVA EC Gas Fired Heating, Ventilation & Cooling Units... ErP 2018 ErP Lot 21 Seasonal Efficiency and Nx compliant ErP 2018 ErP Lot 21 Seasonal Efficiency and Nx compliant PREEVA EC... Gas Fired
More informationBENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS
BENSN... EnviroAir Gas Fired Heating, Ventilation & Cooling Units... AMBIRAD HEATI NG AND VENTILATIN S LUTINS EnviroAir... Gas Fired Heating, Ventilation & Cooling Units... The Benson EnviroAir is a new
More information... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...
LCSA - LCSBD - LCSC Gas Fired Unit Heaters LCSA complete with horizontal and optional vertical louvres LCSA - LCSBD - LCSC... Gas Fired Unit Heaters... The new LCSA builds on the technical excellence of
More informationGas-fired unit heaters for indoor installation
UDSA & UDSBD model Gas-fired unit heaters for indoor installation Reznor V3 unit heaters are one of the most technically advanced products available on the market today. Incorporating a radical new heat
More information... UDSA - UDSBD Gas fired unit heaters...
UDSA - UDSBD Gas fired unit heaters UDSA with axial fan Reznor V3 unit heaters are one of the most technically advanced products available on the market today. Incorporating a radical new horizontal heat
More informationRHC & RHCE gas fired heating coils
APPLICATIONS Heating in duct networks or air handling units >> FACTORIES >> WAREHOUSES >> HALLS RHC & RHCE gas fired heating coils www.reznor.eu RHC gas fired heating coils Reznor gas fired heating coils
More informationSolarWall Fan Units. Introduction. Features. By Conserval Engineering Inc.
SolarWall Fan Units Introduction The SolarWall fan units are designed to be used maximize the supply of solar heated air into the building via fabric ducting. The units are complete with modulating dampers
More informationCI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS
CI/SfB 56.83 X RHeco Series CONDENSING GAS FIRED UNIT HEATERS RHeco Series CONDENSING GAS FIRED UNIT HEATERS Introduction Features & Benefits Model Range Reznor continue their tradition of manufacturing
More informationDF-IDF air handling units
APPLICATIONS Heating, ventilation >> WAREHOUSES >> DISTRIBUTION CENTRES >> FACTORIES >> SPORTS HALLS >> EXHIBITION HALLS DF-IDF air handling units www.reznor.eu DF - IDF air handling units GAS FIRED COMBINED
More information... DF / IDF Gas fired combined heating and ventilation ...
DF / IDF Gas fired combined heating and ventilation Gas fired combined heating and ventilation Introduction The comprehensive range of gas fired air handling units provides high efficiency combined heating
More information... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant
... RHeco... ErP 2021 ErP Lot 21 Seasonal Efficiency and NOx compliant RHeco...... Reznor continue their tradition of manufacturing high efficiency warm air heating equipment with the introduction of the
More information... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant
... RHeco... ErP 2021 ErP Lot 21 Seasonal Efficiency and NOx compliant RHeco...... Reznor continue their tradition of manufacturing high efficiency warm air heating equipment with the introduction of the
More informationCI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION
CI/SfB 56.83 X DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION Introduction Nordair Niche is one of the UK's leading specialists in
More informationRHC GAS FIRED HEATING COILS
CI/SfB 56.83 X RHC GS FIRED HETING COILS RHC GS FIRED REZNOR HETING COILS Introduction Reznor gas fired heating coils are designed for inclusion in air handling units to provide a high efficiency gas fired
More informationBENSON.... Variante3 Fired Unit Heaters...
NSON Variante3 as ired Unit Heaters 3 Variante... as ired Unit Heaters... The new Variante3 builds on the technical excellence of the previous range to provide cost effective and robust heating for industrial
More informationINDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG
INDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG COMMERCIAL/INDUSTRIAL AIR HANDLER AND CONDENSING UNIT AIR HANDLER CAPACITIES 563-7,593 CFM Air 20-400 MBH Heating (Gas/LP) 10-120 kw Heating (Electric) 5-20 Tons
More informationVPC Gas Cabinet Heater Range
VPC Gas Cabinet Heater Range Industrial & Commercial Heating Systems. www.powrmatic.co.uk HEATING // VENTIATION // AIR CONDITIONING // OEM PRODUCTS VPC Overview Models Available VPC UF - Upright Freeblowing
More information... Variante -4E Gas Fired Unit Heaters... ErP. ErP Lot 21 Seasonal Efficiency compliant
... Variante -4 as ired Unit eaters... rp 2018 rp Lot 21 Seasonal fficiency compliant Variante 4... as ired Unit eaters... The new Variante 4 builds on the technical excellence of the previous range to
More informationCP+ Gas & Oil Cabinet Heater Range
CP+ Gas & Oil Cabinet Heater Range Industrial & Commercial Heating Systems. www.powrmatic.co.uk CP+ CP+EA External Heater HEATING // VENTILATION // AIR CONDITIONING // OEM PRODUCTS CP+ Overview Designed
More informationAIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)
AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory
More informationVPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning
VPC Gas Cabinet Heater Range Architects of your environment heating ventilation air conditioning 1 Product Overview Benefits Installer Friendly ow evel Flue Discharge Option (No Roof Work) Room Sealed
More informationRoom sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23
Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B Type B 23 on the wall Ø 80 duct, available in the following lengths: 1000,
More informationAll Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted
All Heaters Part L2B Compliant Technical Data External Oil and Gas Cabinet Heaters For Models EVD Vertical Ducted EHD Hortizontal Ducted Range & Configuration Vertical Forced Draught Oil and Gas 29 kw
More informationCOOLflow 4E PRODUCT RANGE
COOLflow 4E PRODUCT RANGE FREE AIR COOLING FROM THE FREE AIR SPECIALISTS GUARANTEED TO SIGNIFICANTLY REDUCE CARBON EMISSIONS & DELIVER ENERGY SPEND SAVINGS OF UP TO 95% The COOLflow 4E range has been developed
More informationRooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating
Rooftop Ventilator with Packaged Cooling & Heating Models RV and RVE Institutional Commercial Industrial 800-1,500 cfm.0 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating Packaged
More informationOnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!
OnePlus Packaged Air Handling Units for Ducted Installations Caring for the environment! A New Concept New packaged air handling units OnePlus series are the latest offspring of Apen Group s experience.
More informationIndirect Gas-Fired Make-Up Air
Indirect Gas-Fired Make-Up Air Model IG 800 to 7,000 cfm Up to 400,000 Btu/hr Multiple Furnace Control Options Optional Evaporative Cooling May 20041 Product Features Model IG Indirect Gas-Fired Make-Up
More informationMetropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h
Metropolitan Steam Boiler Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing Outputs 1845-21 700 kg/h 1 Metropolitan - Steam Boiler The Metropolitan is a range of high pressure
More informationModular Supply Make-Up Air Unit
Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features
More informationPACKAGED HVAC EQUIPMENT CATALOG
PACKAGED HVAC EQUIPMENT CATALOG COMMERCIAL/INDUSTRIAL HVAC CAPACITIES 5-70 Tons Cooling (Fixed and Modulating Capacity) Dehumidification 1,000-13,000 CFM 100-1,600 MBH (Gas Heating) 8:1 or 16:1 Gas Heating
More informationKINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION
SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to
More informationThe swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.
Halton CSW Swirl comfort unit for ceiling installation The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply. A combined cooling, heating, and supply-air unit for flush
More informationV-Line. Nozzle-mix line burner
V-Line Nozzle-mix line burner Duct Burners - V-Line 4-22.5-1 Nozzle-mixing line burner for use with low pressure natural gas, propane and butane. Suitable for operation in variable process air-flows. Stainless
More informationDirect Gas-Fired Make-Up Air
Direct Gas-Fired Make-Up Air Model TSU Heavy Duty, High Airflow Applications Manufacturing and Industrial Facilities Up to 64,000 cfm August 2012 Products Model TSU Direct Gas-Fired Make-Up Air Unit The
More information... Air Conditioners & Heat Pumps Light Commercial ...
... Air Conditioners & Heat Pumps Light Commercial... Mini Split Mini Split Systems Single-zone mini-splits allow easy addition of heating and cooling to specific areas. Space additions, hot and cold spots,
More informationCommercial Evaporative Cooling
Commercial Evaporative Cooling The Bonaire System Advantage Bonaire has been providing innovative commercial evaporative cooling solutions for over 60 years on projects with applications which have been
More informationLARGE CAPACITY HEATERS
250 1,000 Capacities 7.5-12,850 150,000 CFM 200 MBH 250-7,500 MBH - - Tons APPLICATIONS Heating/Cooling/Makeup Air WAREHOUSES / FACTORIES SCHOOLS / UNIVERSITIES COMMERCIAL / RETAIL INDUSTRIAL GYMNASIUMS
More informationSavile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h
Savile Plus Steam Boiler Suitable for Pressure Jet burners Oil, gas or dual fuel firing Outputs 380-5425 kg/h 1 Savile Plus - Steam Boiler The Savile Plus is a range of three pass wet back reverse flame
More informationCONTROL OPTIONS SPACE HEATING APPLICATIONS MAKEUP AIR HEATING APPLICATIONS PEH, PXH, RDH, REH, RXH, SDH & SHH. Horizontal Split System- Models PDH,
SPACE HEATING APPLICATIONS MAKEUP AIR HEATING APPLICATIONS Options AG3 Unit-Mounted Ductstat Options AG15, AG16 A = Ductstat Temperature Module P/N 115848 B = Stage Adder Module, P/N 115849 (quantity varies
More informationHood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL
The Kitchen Cool by Hood Depot is a conditioned make up air unit design with flexibility, form and function kept in mind. Our unit offers a variety of configurations that allow the customer to customize
More informationSeries. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:
RL Packaged Rooftop Units, heat pumps and Outdoor air handling Units Features: Air-cooled condenser, water-cooled condenser, or patented AAON evaporative-cooled condenser, with capacities from 45-240 tons
More informationSPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module
SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:
More informationGas-Fired Indoor and Outdoor Duct Furnaces
July, 2008 Gas-Fired Indoor and Outdoor Duct Furnaces INDOOR GRAVITY VENTED DFG, DBG, DCG INDOOR SEPARATED COMBUSTION DFS, DBS, DCS OUTDOOR GRAVITY AND POWER EXHAUSTED H Series table of contents A complete
More informationTGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.
TGIF- Indirect Fired Heating Systems Technical Guide for: IF Indoor Installations IFW Outdoor Installations Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide In the business of
More informationIndustrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation
Industrial Space Heating Direct Gas-Fired Heating Greenheat 00% Outdoor Air Greenheat 50/50 Recirculation 80/0 Recirculation March 008 Product Overview Industrial Space Heating Greenheck s space heating
More informationSeries PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:
RZ PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS Features: Air-cooled condenser, water-cooled condenser, or evaporative-cooled condenser packaged rooftop units from 55-240 tons Water-source
More informationHalton Rex 600 Basic R6B - Active chilled beam
Halton Rex 600 Basic R6B - Active chilled beam Halton Rex 600 Basic chilled beam is: A base version to the combined cooling, heating, and supply air unit for flush installation within a suspended ceiling.
More informationTECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:
Biddle Air Systems Limited St. Mary s Road, Nuneaton,Warwickshire CV AU. Tel: + 0 78 Fax: + 0 77 Email: sales@biddle-air.co.uk http://www.biddle-air.co.uk F.H. Biddle B.V. P. O. Box, NL-988 ZG Kootstertille,The
More informationVICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power
VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 is the new wall-hung condensing boiler for room heating only, set-up for independent functioning and for that in cascade mode
More informationINDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG
INDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG COMMERCIAL/INDUSTRIAL AIR HANDLER AND CONDENSING UNIT AIR HANDLER CAPACITIES 563-7,593 CFM Air 75-400 MBH Heating (Gas/LP) 10-120 kw Heating (Electric) 5-20 Tons
More informationHalton Rex for Vario R6O - Variable air volume chilled beam
Halton Rex for Vario R6O - Variable air volume chilled beam Halton Rex for Vario chilled beam is: Combined cooling, heating, and supply air unit for flush installation within a suspended ceiling Well suited
More informationCITY OPEN - CITY BOX from 25 to 35 kw
CITY OPEN - CITY BOX from 25 to 35 kw Technology and automotive innovation, resistance to sun, rain, frost and salt IPX5-10 C Born to resist IPX5-10 C City Open - City Box STAINLESS STEEL COMBUSTION GROUP
More information1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.
SECTION 15855 GAS FURNACE/DX COOLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of contract including General and Supplementary Conditions of Division 1 of Specification
More information... Vision Radiant Tube Heating Systems ... ErP. ErP Lot 20 Seasonal Efficiency and NOx compliant
Vision Radiant Tube Heating Systems ErP 2018 ErP Lot 20 Seasonal Efficiency and NOx compliant * Vision... Radiant Tube Heating Systems... The range of high efficiency Vision radiant tube heaters delivers
More informationDOAS UNITS. ReznorHVAC.com MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR
MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR KITCHENS HOTEL CORRIDORS LABORATORIES CONFERENCE CENTERS SCHOOLS PAINT BOOTHS MALLS/SHOPPING CENTERS DOAS UNITS Capacities 5-30 Tons 50-800 MBH 30-120 kw 650-9,000
More informationRoofVent Design Handbook
RoofVent Design Handbook Supply and Extract Air Handling Units for Heating and Cooling High Spaces RoofVent RH RC RHC R Content RoofVent RH RC RHC R RoofVent RH Supply and extract air handling unit with
More informationCabinet Heaters. Over 91.5% NET Efficient! Quality in Any Language TM. Ideal for industrial and commercial applications
Ideal for industrial and commercial applications arge range of heat outputs and burner options Easy installation with a factory fitted bolt-on burner Durable long life stainless steel combustion chamber
More informationproduct Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners
product Information on oil, gas and dual fuel burners Industrial burners Industrial burners sizes to flexible and reliable Weishaupt Industrial Burners: Flexible and reliable For more than years, Weishaupt
More informationENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical
ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator
More informationFEATURES AND BENEFITS
FEATURES AND BENEFITS Product Features and Benefits Full Product Line Offering Feature All models are 80% thermally efficient Blower performance up to 3.0 W.C. DX or chilled water section with factory
More informationInternal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.
A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall
More informationAVIO kw Export 1 FEATURES. Wall-mounted with storage tank
1 FEATURES Wall-mounted with storage tank Compact wall-mounted open chamber boiler with conventional flue and 45 litre stainless steel storage tank and nominal heat output of 23.7 kw (20,382 kcal/h). AVIO
More informationSKYPAK II, 3 Ton Series, gives you a
SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall
More informationFlue Dilution Fans. Specialists in Air Movement Technology. IMPROVED GBDF MK5 Now includes a Pressure Safety Switch and easier Electrical Connections
Now includes a Pressure Safety Switch and easier Electrical Connections Flue Dilution Fans VISIT US AT www.airflow.com UK SALESLINE 0845 330 1047 Specialists in Air Movement Technology SAFETY - NEW Differential
More informationHOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance
Installation Operation Commissioning Maintenance HOT AIR GENERATOR WITH GAS BURNER GGS NA11.45 A 06-2011 04-2011 CONTENTS 1. DESCRIPTION OF THE UNIT 2. INSTALLATION & CONNECTION 3. COMMISSIONING 4. CARE
More informationPremium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units
Premium Efficiency Heat Recovery Unit D-AHU Modular L Air Handling Units About Daikin Our promise is to ensure that customers can depend on Daikin for the ultimate in comfort, so that they are free to
More informationOur Technology. Your Comfort. ... January. Price Guide Effective until 1st September All prices are ex works. E&OE
Our Technology. Your Comfort... January Price Guide 2019... Effective until 1st September 2019. All prices are ex works. E&OE 01384 489 250 Option 1 Sales reznorquotes@nortek.com Option 4 Service serviceuk.hvac@nortek.com
More informationSKYPAK II, 3 Ton Series, gives you a
SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall
More informationwww.ecso-klimatechnik.de ECSO GMBH Wetterssteimstr. 53 D- 90471,.. Nurnberg, Deutschland e-mail: info@ecso-klimatechnik.de Tel/Fax: +49 (0) 911/818 9917 TABLE OF SYMBOLS OPERATING MODE OPTIONS VENTILATION
More informationNEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet
NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet Simplifying Your Safety Decisions Now it s easy to select the best biological safety cabinet for your work with gases and
More informationKüba SG commercial
GEA Küba 42 Küba Blue Line : Specific advantages High performance air cooler for commercial applications with a large scope and complete capacity spectrum. Draw-through fans guide the air flow evenly through
More information... Autumn. Price Guide Effective 1 st September All prices are ex works. E&OE
... Autumn Price Guide 2018... Effective 1 st September 2018. All prices are ex works. E&OE 01384 489 250 Option 1 Sales reznorquotes@nortek.com Option 4 Service serviceuk.hvac@nortek.com Designs and quotes
More informationApplication instructions
0603RHC4-JLGBEN Application instructions RHC 4000(M) RJL RHC 4000(M) DJL Jacket-less, Gas fired, Balanced flue, Power vented, Air heater This document applies when installing into an air handler or as
More information48TF GAS HEATING/ ELECTRIC COOLING UNITS
48TF-4SB 48TF004-014 GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form
More informationCounterflo CF BASIC COUNTERFLO HEATER RCF CURB MOUNTED ROOFTOP HEATER CFDF COUNTERFLO DUCT FURNACE INDIRECT-FIRED INDUSTRIAL HEATERS
Bulletin CF-1 May 2005 Supersedes CF-1 Dated February 1998 Counterflo INDIRECT-FIRED INDUSTRIAL HEATERS Self-contained, Automatic, Indirect-fired, Warm-air Heater C.S.A. APPROVED UNITS AVAILABLE Natural
More informationGLOBAL FINISHING SOLUTIONS
GLOBAL FINISHING SOLUTIONS > Eliminate problems with drafts, stale or contaminated air, and temperature stratification > Create balanced building pressure and maintain proper comfort levels > Introduce
More informationProducts and prices. CLIMATE TECHNOLOGY feels better, works better.
Products and prices CLIMATE TECHNOLOGY feels better, works better. www.markclimate.com Long-term leaders in climate management Get to know the specialist in the Netherlands in the field of air heating,
More informationCI/SfB X. Vision RADIANT TUBE HEATING SYSTEMS
CI/SfB 56.83 X Vision RADIANT TUBE HEATING SYSTEMS Vision RADIANT TUBE HEATING SYSTEMS Introduction The new range of high efficiency Vision radiant tube heaters delivers exceptional performance in terms
More informationMay, 2004 Commercial & Industrial Applied Product Line Heating Ventilating Cooling Make-Up Air
75-137.5 May, 2004 Commercial & Industrial Applied Product Line Heating Ventilating Cooling Make-Up Air MODINE COMMERCIAL & INDUSTRIAL APPLIED PRODUCT LINE Modine has always been the industry standard
More informationSystem Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.
System Components with ` Emphasis on Packaged Rooftop Application and Installation Jerry Cohen President Jacco & Assoc. Agenda Define and relate in practical terms the following components: System Effect
More informationThe ultimate in air handling units: directly and indirectly fired
AHU The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake
More informationDERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E
DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E INTRODUCTION DERV/ERV Introduction Dehumidification & Energy Recovery Ventilator DERV units
More informationDirect Fired Heater Model AD Specification
Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI
More informationETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT
90% EFFICIENCY HIGHEST EFFICIENCY AIR HANDLING UNIT Packaged energy recovery solutions for Green Buildings Integrated Accumulator, controls and DX Cooling System CLEAN AIR SINCE 1963 Euroclima is a company
More informationEnergy Recovery with Cooling and Heating Model ERCH
Energy Recovery with Cooling and Heating Model ERCH 100% Outdoor Air System Dedicated Outdoor Air System 1,000-10,000 cfm 1.75 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating,
More informationExternal insulated volume. control damper
EPP Air Handling Unit with swept internal air flow paths Steel powder coated frame Acoustic Air treatment zone External insulated volume control damper 24V Actuators to dampers Internal louvre grille supplied
More informationHi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE
Hi-Pres Self Contained A/C Unit TYPE SCU-C & SCU-W Product specifications HI-PRES MARINE & OFFSHORE Contents Introduction..................... 2 Type SCU-W.......................... 2 Type SCU-C...........................
More informationPRODUCT RANGE: ROOFTOP PACKAGE
Packaged Air Cooled Reverse Cycle Type Air Conditioner Range 11-125kWr With Energy / Heat Recovery The Roof Top Packaged unit range is designed to be used when high fresh air quantities are required. They
More informationCenteral Station Air Handling Unit
Centeral Station Air Handling Unit CA Series www.windind.com www.windind.com The product range includes double skinned Air Handling Units, double skinned Fan Coil Units, and custom designed packaged roof
More informationDirect Gas-Fired Make-Up Air Models DG and DGX
Direct Gas-Fired Make-Up Air Models DG and DGX Commercial, Industrial and Kitchen Applications 800-48,000 cfm 4 in. wg External Static Pressure Direct Gas-Fired Heating Optional Cooling - Packaged DX (2.5
More informationGas heaters and convectors ROBUR
Gas heaters and convectors ROBUR Table of Contents Robur M general characteristic...3 Robur M dimensions...3 Robur M construction...4 Robur M technical data...5 Robur M installation...6 Robur M accessories...7
More informationThe ultimate in air handling units: directly and indirectly fired
KLIMAT The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake
More informationRL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw
The RL/1 burners series covers a firing range from 107 to 398 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Optimisation
More information1 VICTRIX ZEUS Superior kw I features
Wall-hung condensing VICTRIX ZEUS Superior kw I is the new range of wall-hung condensing boilers with 54 litre stainless steel storage tank available in two versions with nominal heat output of 26 kw and
More information42AM. Air heaters PRODUCT SELECTION DATA
PRODUCT SELECTION DATA The best solution for heating large spaces Ensures buildings warm up ultra-fast Excellent diffusion via patented JET+ double deflection technology Air heaters 4AM Translation of
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationPK-N Floor Standing Heater
PK-N Floor Standing Heater The experience is mixed with technology A solution for any necessity High efficiency Heat exchanger in inox steel 55 PK-N: the heat that lasts in time Apen Group has redesigned
More informationWeishaupt dual fuel burners Sizes 30 to 70 Version 1LN (NO X -reduction on gas operation) 1/2003 CA
Weishaupt dual fuel burners Sizes 30 to 70 Version 1LN (NO X -reduction on gas operation) 1/2003 CA Description Weishaupt burners of sizes 30 to 70 were specially designed and developed for industrial
More informationG34M Bulletin #69/ August 2003
ENGINEERING DATA G34M MULTI POSITION GAS FURNACE 12.4 to 31.0 kw Output 52.7 to 131.9 Mj Input 3.5 to 17.6 kw Nominal Add-on Cooling GAS FURNACES 50 Hz G34M Bulletin #69/490045 August 2003 Typical Applications
More information