1 Installation, use and maintenance instructions Manuel d entretien Installatie-, gebruiks- en onderhoudsvoorschriften GB F NL Oil burners Brûleurs fioul Stookoliebranders One stage operation Fonctionnement à allure Eentrapsbranders CODE MODEL - MODELE TYPE SIME MACK SP 55 T SIME MACK 5SP 55 T5 90 (0)
2
3 INDEX. BURNER DESCRIPTION Burner equipment TECNICAL DATA Technical data Overall dimensions Working fields INSTALLATION Boiler fixing ydraulic systems Electrical wiring WORKING Combustion adjustment Nozzles recommended Electrodes setting Air damper adjustment Pump pressure Burner start-up cycle MAINTENANCE FAULTS / SOLUTIONS BURNER DESCRIPTION One stage light oil burner suitable for working with fuel temperature higher than 0 C. The burner meets protection level of IP 0, EN Burner with CE marking in conformity with EEC directives: EMC 89/6/EEC, Low Voltage 7//EEC, Machines 98/7/EEC and Efficiency 9//EEC. Fig D67 Oil pump Control-box Reset button with lock-out lamp ydraulic jack with air-damper 5 Screws fixing air-damper 6 Flange with insulating gasket 7 Grommet. BURNER EQUIPMENT Flange with insulating gasket....no. Screws and nuts for flange to be fixed to boiler.. No. Screw and nuts for flange......no. Flexible oil pipes with nipples No. Grommet No. 7 pin plug No. GB
4 . TECNICAL DATA. TECNICAL DATA Model MACK SP MACK 5SP Output kg/h Thermal power kw ( i =.86 kwh/kg) Fuel Light oil, max. viscosity at 0 C: 6 mm /s Electrical supply Single phase, ~ 50z 0V ± 0% Motor Run current 0.7A 850 rpm 98 rad/s Capacitor µf Ignition transformer Secondary 8 kv 6 ma Pump Absorbed electrical power Pressure: 7 5 bar 0. kw. OVERALL DIMENSIONS Flange 80 9 = Burner = ø 89 5 D D66. WORKING FIELDS (as EN 67) Pressure in the combustion chamber mbar,0 0,8 0,6 0, MACK SP MACK 5SP 0, 0,8,,,6,8,,,6,8 Light oil output kg/h D Thermal power kw GB
5 . INSTALLATION. BOILER FIXING Put on the flange () the screw and two nuts, (see fig. ). Widen, if necessary, the insulating gasket holes (5). Fix the flange () to the boiler door () using screws () and (if necessary) the nuts () interposing the insulating gasket (5), (see fig. ). Fig. Fig. 5 E9 E9 GB
6 . YDRAULIC SYSTEMS The burner is designed to allow entry of the flexible oil-lines on either side of the burner. WARNING: It is necessary to install a filter on the fuel supply line. The standard filter code and that one with recirculation code 6760 are available on request. The pump is designed to allow working with two pipes. In order to obtain one pipe working it is necessary to unscrew the return plug (), remove the by-pass screw () and then screw again the plug (), (see fig. ). Before starting the burner make sure that the return pipe-line is not clogged. An excessive back pressure would cause the damage of the pump seal. Fig max. m D68 SYSTEM NOT PERMITTED IN GERMANY Fig. 5 meters PRIMING PUMP: On the system in fig. 5 it is sufficient to loosen the suction gauge connection (6, fig. ) and wait until oil flows out. On the systems in fig. 6 and 7 start the burner and wait for the priming. Should lock-out occur prior to the arrival of the fuel, await at least 0 seconds before repeating the operation. The pump suction should not exceed a maximum of 0. bar (0 cm g). Beyond this limit gas is released from the oil. Oil pipes must be completely tight. In the vacuum systems (fig. 7) the return line should terminate within the oil tank at the same level as the suction line. In this case a non-return valve is not required. Should however the return line arrive over the fuel level, a non-return valve is required. This solution however is less safe than previous one, due to the possibility of leakage of the valve I. D. 8 mm L meters I. D. 0 mm D59 - Suction line - Return line - By-pass screw - Gauge connection 5 - Pressure adjuster 6 - Suction gauge connection 7 - Oil valve 8 - Auxiliary pressure test point meters I. D. 8 mm L meters I. D. 0 mm max. m Fig. 6 Fig. 7 max. m D685 = difference of level; L = max. length of the suction line; I. D. = internal diameter of the oil pipes. GB
7 . ELECTRICAL WIRING WARNING DO NOT EXCANGE NEUTRAL WIT PASE ~ 50z 0V PE L N Main switch NOTES: Wires of mm section. The electrical wiring carried out by the installer must be in compliance with the rules in force in the Country. TESTING Check the shut-down of the burner by opening the thermostats. T6A Limit thermostat with manual resetting Regulating thermostat our counter (0V - 0.A max.) Remote lock-out lamp (0V - 0.5A max.) CONTROL BOX To remove the control-box from the burner, loosen screw (A, fig. 8) and pull to the arrow direction, after removing all components, the 7 pin plug and earth wire. 7 pin plug Fig. 8 7 pole socket CARRIED-OUT IN TE FACTORY CONTROL BOX 55SE Black White Blue Motor Oil valve Capacitor E957 A Ignition electrodes Photoresistance Burner-earth D86 Fig. 9 ACCESS TO TE POTORESISTANCE (See fig. 9) The photoresistance is fitted directly into the control-box (underneath the ignition-transformer) on a plug-in support. Ignition transformer Photoresistance E90 5 GB
8 . WORKING. COMBUSTION ADJUSTMENT In conformity with Efficiency Directive 9//EEC the application of the burner on the boiler, adjustment and testing must be carried out observing the instruction manual of the boiler, including verification of the CO and CO concentration in the flue gases, their temperatures and the average temperature of the water in the boiler. To suit the required appliance output, fit the proper nozzle, then adjust the pump pressure and the air damper opening in accordance with the following table. ADJUSTMENTS CARRIED OUT IN FACTORY FOR SIME BOILERS The values shown in the table are measured on a SIME boiler (as per EN 67). They refer to.5% CO at sea level and with light oil and room temperature of 0 C. Table B Pump pressure Burner output APPROXIMATE ADJUSTMENTS FOR INSTALLATION ON OTER BOILERS The values shown in the table are measured on a CEN boiler (as per EN 67). They refer to.5% CO at sea level and with light oil and room temperature of 0 C. Air damper adjustment BOILER BURNER Nozzle Code Model GP Angle bar kg/h ± % Set-point Rondò-Estelle MACK SP W Rondò-Estelle MACK 5SP W.6 v8 Model Nozzle Pump pressure Burner output Air damper adjustment GP Angle bar kg/h ± % Set-point Fig. 0 MACK SP MACK 5SP NOZZLES RECOMMENDED: Monarch type R - NS ; Delavan type W-E Steinen type - Q ; Danfoss type - S. MAINTENANCE POSITION Access to the combustion head, electrodes and nozzle, (see fig. 0). Remove the burner out of the boiler, after loosing the fixing nut to the flange. ook the burner to the flange (), by removing the combustion head () after loosing the fixing screws (). Remove the electrodes assembly (5) from the nozzle-holder () after loosing its fixing screw (B, fig., page 7). Screw the nozzle (6). E955 6 GB
9 . ELECTRODES SETTING ATTENTION Fig. ± 0. mm IMPORTANT: TESE DIMENSIONS MUST BE OBSERVED Before removing or assembling the nozzle, loosen the screw (B, fig. ) and move the electrodes ahead. D50 B.5 mm. AIR DAMPER ADJUSTMENT, (see fig. ) The mobile air damper () operated by the jack () assures the complete opening of the air intake. The regulation of the air-rate is made by adjusting the fixed air damper (), after loosing the screws (). When the optimal regulation is reached, screw tight the screws () to assure a free movement of the mobile air damper (). The settings, indicated in the table (page 6), refer to the burner with its cover fitted and combustion chamber with depression zero. These Fig. regulations are purely indicative. Each installation however, has its own unpredictable working conditions: actual nozzle output; positive or negative pressure in the combustion-chamber, the need of excess air, etc. All these conditions may require a different air-damper setting. It is important to take account of the fact that the air output of the fan differs according to whether the burner has its cover fitted or not. Therefore we recommended to proceed as follows: Adjust the air damper as indicated in the table. Mount the cover. Check smoke number and CO. Should it become necessary to modify the air output, remove the cover by loosening the screw, adjust the air damper, remount the cover and finally recheck the smoke number. D686.5 PUMP PRESSURE: The pump is set in factory according to the value indicated in the table B at page 6. bar: Improves flame retention; it is therefore suitable for ignitions at low temperatures..6 BURNER START-UP CYCLE Thermostat Green led and motor Ignition transformer Oil valve Flame Lock-out lamp Normal Lock-out due to failure to light C ~ s ~ s 5s D509 C Lock out is indicated by a lamp on the control box (, fig., page ). 7 GB
10 5. MAINTENANCE Burner requires a periodic maintenance carried out by a qualified and authorized technicians. Maintenance is essential for the reliability of the burner, avoiding the excessive consumption of fuel and consequent pollution. Before carrying out any cleaning or control always first switch off the electrical supply to the burner acting on the main switch of the system. TE BASIC CECKS ARE: Check that there are not obstructions or dents in the supply or return oil pipes. Clean the filter in the oil suction line and in the pump. Clean the photoresistance, (see fig. 9, page 5). Check for correct fuel consumption. Replace the nozzle (see fig. 0, page 6) and check the correct position of electrodes (fig., page 7). Clean the combustion head in the fuel exit area, on the diffuser disc. Leave the burner working without interruptions for 0 min. and set rightly all the components stated in this manual. Then carry out a combustion check verifying: Smoke temperature at the chimney; Content of CO (%); Content of CO (ppm); Smoke value according to opacity smokes index according to Bacharach scale. 8 GB
11 6. FAULTS / SOLUTIONS ere below you can find some causes and the possible solutions for some problems that could cause a failure to start or a bad working of the burner. A fault usually makes the lock-out lamp light which is situated inside the reset button of the control box (, fig., page ). When lock out lamp lights the burner will attempt to light only after pushing the reset button. After this if the burner functions correctly, the lock-out can be attributed to a temporary fault. If however the lock out continues the cause must be determined and the solution found. FAULTS POSSIBLE CAUSES SOLUTION Check presence of voltage in the L - N clamps of the 7 pin plug. The green led on the control box is off and the burner does not start. The green led on the control box is on and the burner remains in the prepurge phase. Burner runs normally in the prepurge and ignition cycle and locks out after 5 seconds ca. Burner starts with an ignition delay. Lack of electrical supply. The connections in the control box are wrongly inserted. The photoresistance sees false light. The photoresistance is dirty. The photoresistance is defective. Flame moves away or fails. The ignition electrodes are wrongly positioned. Air output is too high. Nozzle dirty or worn. Check the conditions of the fuses. Check that thermostat limit is not lock out. Check and connect completely all the plugs. Eliminate the light. Clear it. Change it. Check pressure and output of the fuel. Check air output. Change nozzle. Check the coil of solenoid valve. Adjust them according to the instructions of this manual. Set the air output according to the instructions of this manual. Replace it. WARNING The manufacturer cannot accept responsibility for any damage to persons, animals or property due to error in installation or in the burner adjustment, or due to improper or unreasonable use or non observance of the technical instruction enclosed with the burner, or due to the intervention of unqualified personnel. 9 GB
Parts Available from
Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Installatie-, gebruiks- en onderhoudsvoorschriften Oδηγίες εγκατάστασης, χρήσης και συντήρησης D F GB NL
More informationLight oil burners. One stage operation
Installation, use and maintenance instructions Light oil burners One stage operation CODE MODEL TYPE 3505 RDB CF 38 50 T3 350050 RDBR CF 6 50 TR 35050 RDBR CF 33 50 TR 35050 RDBR CF 38 50 T3R 350650 RDBR
More informationLight oil - kerosene burner
Installation, use and maintenance instructions Light oil - kerosene burner One stage operation CODE MODEL TYPE 374374 G3B 437T 90 (4) - 05/0 TECHNICAL FEATURES TYPE 437T Thermal power output 9 35 kw.6
More informationLight oil / kerosene burner
Installation, use and maintenance instructions Light oil / kerosene burner One stage operation CODE MODEL TYPE 374445 G5 444T50 290238 (5) - 05/20 TECHNICAL DATA Thermal power output 28 60 kw 2.3 5 kg/h
More informationGas-Gebläsebrenner Brûleur gaz à air soufflé Forced draught gas burner Gasventilatorbrander Quemador de gas de aire soplado
Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Installatie-, gebruiks- en onderhoudsvoorschriften Instrucciones para la instalación, uso y mantenimiento
More informationINSTRUCTION MANUAL FOR OIL BURNER MODELS
INSTRUCTION MANUAL FOR OIL BURNER MODELS X500 Bio B10 E90-803-001-001-00 Rev 7-1 - Contents Technical specifications Technical data... 3 Working field... 3 Dimensions... 4 Head and electrode settings...
More informationINSTRUCTION MANUAL FOR OIL BURNER MODELS
INSTRUCTION MANUAL FOR OIL BURNER MODELS X400 Bio B10 E90-803-001-001-03 Rev 13-1 - Contents Technical specifications Technical data... 3 Working field... 3 Dimensions... 4 Head and electrode settings...
More informationSingle stage operation oil burner
Installation & Operating Manual Single stage operation oil burner WARNING NON-RETROFIT APPLICATIONS If this burner is being installed in a packaged unit (ie. burner comes with a boiler or furnace), follow
More informationSingle stage operation oil burner
Installation & Operating Manual Single stage operation oil burner WARNING NON-RETROFIT APPLICATIONS If this burner is being installed in a packaged unit (ie. burner comes with a boiler or furnace), follow
More informationForced draught gas burner
Installation, use and maintenance instructions Forced draught gas burner Code Model Type 3751982 GAS 3 519T80 291 (3) - 02/2010 DECLARATION Declaration of conformity in accordance with ISO / IEC 17050-1
More informationCODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80
Installation, use and maintenance instructions Heavy oil burner CODE MODEL TYPE 3434985 PRESS 60 N 616 T80 3434986 PRESS 60 N 616 T80 291 (2) - 01/2009 Thermal power - Output Operation Fuel Electrical
More informationInstallation & Maintenance Manual
Installation & Maintenance Manual MOL 200 S1L (B30A) Oil Burner 11/12 Tel: +44 (0) 1905 794331 Fax: +44 (0) 1905 794017 Email: info@nu-way.co.uk Web: www.nu-way.co.uk DESCRIPTION COMPONENTS 1. Shrouded
More informationINSTRUCTION MANUAL FOR OIL BURNER MODELS
INSTRUCTION MANUAL FOR OIL BURNER MODELS X500-2 Low voltage 12v dc Brushed motor E90-803-001-005-01 Rev 4-1 - Contents Technical specifications Technical data...3 Working field...3 Dimensions...4 Head
More informationRL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw
The RL/1 burners series covers a firing range from 107 to 398 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Optimisation
More informationProviding sustainable energy solutions worldwide. Installation- and maintenance instruction B 10 E R
178 013 03-2 2016-05-26 Providing sustainable energy solutions worldwide Installation- and maintenance instruction B 10 E R DESCRIPTION Components 1. Scale, nozzle assembly 2. Nozzle assembly adjustment
More informationForced draught gas burner
Installation, use and maintenance instructions GB Forced draught gas burner One stage operation CODE MODEL TYPE 3751782 GAS 5 517T80 291 (4) - 07/2015 Declaration of conformity in accordance with ISO /
More informationProviding sustainable energy solutions worldwide. Installation- and maintenance instruction MOL1650 T3N 323 2FH.
178 024 63-2 2016-11-22 Providing sustainable energy solutions worldwide Installation- and maintenance instruction MOL1650 T3N 323 2FH No control DISCRIPTION Components 2 3 4 5 6 7 8 9 18, 19 13 10 17
More information15 20 kw kw kw
Burner Set-up Details 15 20 kw 20 26 kw 29 36 kw Riello RDB2 Please read these instructions carefully before commissioning and using this appliance. To be retained by the householder HEALTH AND SAFETY
More informationBIX B-One 100 kw INSTALLATION GUIDE
BIX B-One 100 kw INSTALLATION GUIDE Dear Customer, We thank you for choosing our product. The Bix B-One 100 Kw is a burner of advanced concept and technology, with a high reliability and construction quality.
More informationProviding sustainable energy solutions worldwide. Installation- and maintenance instruction B 30 A
178 038 51-2 2016-07-08 Providing sustainable energy solutions worldwide Installation- and maintenance instruction B 30 A DESCRIPTION Components 1. Shrouded disc 2. Nozzle 3. Ignition electrodes 4. Nozzle
More informationInfrared Diesel Heater
Infrared Diesel Heater Model No: IRD40 PART NO: 6920415 OPERATING & MAINTENANCE INSTRUCTIONS GC0812 INTRODUCTION Thank you for purchasing this CLARKE Diesel Infrared Heater. Before attempting to use the
More informationINSTALLATION AND MANINTENANCE INSTRUCTIONS
INSTALLATION AND MANINTENANCE INSTRUCTIONS Appr. Nr. A 9503 T - 0085 AQ 0765 PEGASUS F2 T HIGH EFFICIENCY GAS-FIRED CAST-IRON BOILERS Models 51-68 - 85-102 2 Contents 1. General technical data 2. Dimensional
More informationTWO STAGE HEAVY OIL BURNERS
TWO STAGE HEAVY OIL BURNERS PRESS N SERIES PRESS 30 N 85/171 342 kw PRESS 45 N 114/205 513 kw PRESS 60 N 171/342 684 kw PRESS 100 N 285/490 1140 kw The PRESS N series of burners covers a firing range from
More informationInstallation and operating instructions B1FUV Classic
Installation and operating instructions B1FUV Classic 1 171 135 10 05-02 178 033 31 Contents 01. GENERAL... 5 Description... 5 Declaration of conformity... 6 Safety directions... 7 02. TECHNICAL DATA...
More informationRETROFIT APPLICATIONS ONLY
Installation & Operating Manual WARNING RETROFIT APPLICATIONS ONLY If this burner is being installed in a packaged unit (ie. burner comes with a boiler or furnace), follow the installation and set-up instructions
More informationServicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use
GB122 7210 1300-12/2002 GB(EN) For trade use Servicing manual Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C Please read thoroughly before attempting to diagnose fault List of contents
More informationJUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS
JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS Before using the heater, read and understand all instructions and follow them carefully. The manufacturer is not responsible for damages to goods
More informationOil TRIANCO. EuroStar Range BURNER DETAILS TRIANCO - OIL BURNER. To be retained by householder
TRIANCO Oil TRIANCO - OIL BURNER BURNER DETAILS EuroStar Range To be retained by householder TECHNICAL DATA NOZZLE OUTPUT MODEL Output Burner Nozzle Pump Model pressure CO 2 (%) EUROSTAR UTILITY 50/65
More informationServicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use
GB122 Servicing manual Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C For trade use Please read thoroughly before attemting to diagnose fault 7217 4900 (03/2010) GB/IE List of contents
More informationINSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual )
INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual ) FOR USE WITH MODEL: OH6FX072DV4 PLEASE READ THESE INSTRUCTIONS PRIOR TO INSTALLATION, INITIAL FIRING, AND BEFORE
More informationSingle stage operation forced draught natural gas/propane burner
Installation & Operating Manual Single stage operation forced draught natural gas/propane burner The following pages contain information, descriptions and diagrams for the proper installation and wiring
More informationInstallation & Maintenance Manual
Installation & Maintenance Manual Series SD fully automatic oil burners Selectos SD170 Oil Burner Tel: +44 (0) 1905 794331 Fax: +44 (0) 1905 794017 Email: info@nu-way.co.uk Web: www.nu-way.co.uk IMPORTANT
More informationST 40 Oil Burner. Installation & Maintenance Manual
ST 40 Oil Burner Installation & Maintenance Manual 178 093 13 Thank you for choosing a Nu-way burner. As you would expect from a Company who has a pedigree of more than 75 years in the heating industry,
More informationSingle stage operation oil burners
Installation & Operating Manual Single stage operation oil burners WARNING RETROFIT APPLICATIONS ONLY If this burner is being installed in a packaged unit (ie. burner comes with a boiler or furnace), follow
More information2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION
FONDERIE SIME S.p.A. of Via Garbo 27 - Legnago (VR) - Italy declares that its diesel-burning boilers are produced in accordance with the requirements of article 3 paragraph 3 of Directive PED 97/23/EEC
More informationForced draught natural gas/propane burner
Installation, use and maintenance instructions GB Forced draught natural gas/propane burner Single stage operation CODE MODEL 20096942 G400 (2) - 11/2015 Original instructions TABLE OF CONTENTS Installation
More informationATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL
STREBEL GENEVA CE ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL INDEX TABLE 1 TECHNICAL DATA SECTION 1 SECTION 2 SECTION 3 SECTION 4 SECTION 5 SECTION 6 SECTION 7 SECTION 8 SECTION
More informationRIELLO 40 GS/M SERIES
The Riello 40 GS/M series of two stage progressive or modulating gas burners, is a complete range of products developed to respond to any request of gas burners for hot air generator according to EN 1020.
More informationProviding sustainable energy solutions worldwide. Installation- and maintenance instruction B 45A
178 017 55-1 2016-05-19 Providing sustainable energy solutions worldwide Installation- and maintenance instruction B 45A DESCRIPTION Components 1. Flame cone 2. Ignition electrodes 3. Nozzle assembly
More informationRETROFIT APPLICATIONS ONLY
Installation & Operating Manual Single stage operation oil burners RETROFIT APPLICATIONS ONLY If this burner is being installed in a packaged unit (ie. burner comes with a boiler or furnace), follow the
More informationInstallation and operating instructions B2KSV Classic
Installation and operating instructions B2KSV Classic 1 171 135 26 05-01 178 044 33 Contents 01. GENERAL... 5 Description... 5 Declaration of conformity... 6 Safety directions... 7 02. TECHNICAL DATA...
More informationPropane Heater REMKO PGM 30 REMKO PGM 60
Propane Heater REMKO PGM 30 REMKO PGM 60 Operation Technology Spare Parts Edition GB L07 REMKO strong as a bear. Operating instructions Make sure to read these instructions carefully before starting/using
More informationOil burners fuel unit with solenoid valve
Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Germany VM_e.pdf - 18.05.08 Page 1/6 Oil burners fuel unit with solenoid valve
More informationDOMESTIC WATER HEATER OIL FIRED
DOMESTIC WATER HEATER OIL FIRED Models : CMO32-II CMO32-II-R CMO50-II CMO32-II & CMO32-II-R INSTALLER / SERVICE TECHNICIAN: USE THE INFORMATION IN THIS MANUAL FOR THE INSTALLATION AND SERVICING OF THE
More informationDH-Direct Fired Poultry Farm Diesel Heater
DH-Direct Fired Poultry Farm Diesel Heater Comparison of Diesel Heater to Gas Heater Diesel LPG Gas LPG Gas KW 43 70 120 Fuel consumption/hr 3 5.1 8.8 Heat output 37000 60000 100000 Cost of fuel/lit or
More informationHeating Equipment. gas boilers RX GB. installation and servicing instructions
Heating Equipment gas boilers RX GB installation and servicing instructions CONTENTS 1 TECHNICAL FEATURES AND DIMENSIONS 1.1 BOILER DESCRIPTION.............................................. page 1 1.2
More informationMikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc
Mikrofill Ethos Condensing combination boiler Maintenance Instructions 24cc IMPORTANT Benchmark Installation, Commissioning and Service Record Log Book is enclosed in your customer information pack. This
More informationREMKO CLK Mobile automatic heater
REMKO CLK Mobile automatic heater Operation Technology Spare Parts Edition GB M04 REMKO - powerful like a bear. Operating Instructions Read these instructions carefully before setting up/operating the
More informationDF400/DF600. Construction Heaters. Installation and Maintenance Manual
342 N. Co. Rd. 400 East Valparaiso, IN 46383 219-464-8818 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. DF400/DF600 Construction
More informationCMO32 CMO50 DOMESTIC WATER HEATER OIL-FIRED. Models: CMO32 CMO50
DOMESTIC WATER HEATER OIL-FIRED Models: CMO32 CMO50 DNS-1102 Rev. A DNS-0413 Rev. A CMO32 CMO50 INSTALLER / SERVICE TECHNICIAN: USE THE INFORMATION IN THIS MANUAL FOR THE INSTALLATION AND SERVICING OF
More informationInstallation, use and maintenance instructions. Kerosene burner. One stage operation CODE MODEL TYPE RDB2.2 FIREBIRD C20 70K DGT 744LD2X
Installation, use and maintenance instructions Kerosene burner One stage operation CODE MODEL TYPE 20034605 RDB2.2 FIREBIRD C20 70K DGT 744LD2X (4) - 08/2015 Contents 1 Declaration... 3 2 Information
More informationproduct Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners
product Information on oil, gas and dual fuel burners Industrial burners Industrial burners sizes to flexible and reliable Weishaupt Industrial Burners: Flexible and reliable For more than years, Weishaupt
More informationIDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80
IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 EN OPERATING MANUAL OIL HEATER TRT-BA-IDE20-30-50-60-80-TC-001-EN Table of contents Information on the use of this manual... 1 Scope of delivery... 1 General safety...
More informationOil burners fuel unit with solenoid valve
Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Italy - DE112/0404 Oil burners fuel unit with solenoid valve Type VM The DELTA
More informationTechnical information. Remeha P200. Pressurized boiler. Heat output: kw
Technical information Remeha P200 R e m e h a P 2 0 0 Pressurized boiler Heat output: 59-256 kw Remeha P 200 CONTENTS Preface 3 1. Description of the unit 4 1.1 General 4 1.2 Burners 4 2. Construction
More informationTermEfekt USER S MANUAL AIR HEATER. Model PGA 14
Przedsiębiorstwo Produkcyjno-Wdrożeniowe ARAJ sp. z o.o. 55-080 Kąty Wrocławskie, ul. Mireckiego 30 POLAND USER S MANUAL AIR HEATER TermEfekt Model PGA 14 Kąty Wrocławskie, 2004 Product identification
More informationFLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING
FLAME115 INFRARED HEATER SERVICE MANUAL INDEX 1. CONTROLS AND COMPONENTS 2. FLAME CONTROL CYCLES 3. MAINTENANCE SCHEDULE 4. TROUBLESHOOTING GUIDE 5. REPAIR PROCEDURES 1. FAN MOTOR ASSEMBLY 2. FUEL FILTER
More informationProviding sustainable energy solutions worldwide. Installation- and maintenance instruction B 45 A2.2
178 005 56-3 2017-10-11 Providing sustainable energy solutions worldwide Installation- and maintenance instruction B 45 A2.2 2 Bentone 1. Table of contents 1. Viktigt att tänka på! 4 2. Installation 7
More informationRMG IT ES PT GB FR BE
RMG IT ES PT GB FR BE INSTALLER INSTRUCTIONS ENGLISH CONTENTS 1 DESCRIPTION OF THE BOILER........................................................................ pag. 38 2 INSTALLATION.......................................................................................
More informationInstructions Manual SHC520X - SHC700X
Instructions Manual SHC520X - SHC700X INDEX EN RECOMMENDATIONS AND SUGGESTIONS... 3 CHARACTERISTICS... 4 INSTALLATION... 5 USE... 7 MAINTENANCE... 8 2 RECOMMENDATIONS AND SUGGESTIONS The Instructions for
More informationINSTALLATION, OPERATING AND SERVICING INSTRUCTIONS BG 2000-S (V13) RU PL DE IT ES NL EN 1 662Y0600 A
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS G 2000-S 25-35 - 45-55 60-70 - 100 (V13) 1 Index WARNINGS GAS FLOW RATE DIMSIONS SETTINGS PARAMETERS SERVICING THE URNER 3 8 13 OPERATING DESCRIPTION
More informationUSERS MANUAL FOR GAS BOILERS
USERS MANUAL FOR GAS BOILERS PLEASE READ THE MANUAL CAREFULLY: IT CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, INSTALLATION, USE AND MAINTENANCE OF THE APPLIANCE MODELS: NOVADENS 24 NOVADENS 24C NOVADENS
More informationIST 03 C ELBA DUAL INSTALLATION, USE AND MAINTENANCE
IST 03 C 202-01 ELBA DUAL INSTALLATION, USE AND MAINTENANCE GB Thank you for choosing our boilers. Please read these installation and maintenance instructions with care. Please note that the boiler must
More informationINSTALLER INSTRUCTIONS
RS IT ES PT GB INSTALLER INSTRUCTIONS ENGLISH CONTENTS 1 DESCRIPTION OF THE BOILER............................................................................. 49 2 INSTALLATION............................................................................................
More informationWeishaupt WG10 and WG20 gas burners LN (Low NO x ) version 2/2002 CA
Weishaupt WG0 and WG20 gas burners LN (Low NO x ) version 2/2002 CA New W series capacity range The Weishaupt WG0 and WG20 gas burners join the WG5, WG30 and WG40 to complete the line-up of products successfully
More informationSECTION AUXILIARY HEATER
14-301.03/ 1 2010MR12 SECTION 14-301.03 GENERAL DESCRIPTION The Thermo 300 auxiliary heating system is used in conjunction with the vehicle s heating system, in order to heat the passenger compartment
More informationOPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS
OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-200 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA B140.02003
More informationUV Flame Supervision System
7 783 UV Flame Supervision System DETACTOGYR LFE50 Series 02 ISO 9001 The LFE50 is a self-checking UV flame supervision system designed for use with continuously operating burners or for burners running
More information40 SERIES GAS BURNER MODEL 400 NATURAL GAS/PROPANE INSTALLATION INSTRUCTIONS AND OWNER S HANDBOOK
40 SERIES GAS BURNER MODEL 400 NATURAL GAS/PROPANE INSTALLATION INSTRUCTIONS AND OWNER S HANDBOOK CAUTION: All gas burners MUST be installed by trained and licensed technicians. WARNING: Installation of
More informationLFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02
7 783 ISO 9001 DETACTOGYR Flame Safeguard Series 02 The... together with the QRA50M / QRA51M form a self-checking flame supervision system (DETACTOGYR ) designed for use with continuously operating oil
More informationGrant UK VortexBlue. 21, 26 and 36kW Blue Flame Oil Boiler Range. Supplementary Installation, Servicing and User Instructions
Grant UK VortexBlue 21, 26 and 36kW Blue Flame Oil Boiler Range Supplementary Installation, Servicing and User Instructions UK DOC 0108 Rev 1.1 April 2016 GRAT EGIEERIG (UK) LIMITED Hopton House, Hopton
More informationRL 28/2-38/2-50/2 Low - High Operation
Installation, use and maintenance instructions Light Oil Burners RL 28/2-38/2-50/2 Low - High Operation C6505050 CONTENTS WARNING TECHNICAL DATA..............................page 3 Burner models.....................................
More informationOPERATING & MAINTENANCE MANUAL INDUSTRIAL DIRECT FIRED DIESEL/KEROSENE HEATERS IC 25
OPERATING & MAINTENANCE MANUAL INDUSTRIAL DIRECT FIRED DIESEL/KEROSENE HEATERS IC 25 NOT FOR DOMESTIC USE SPACE HEATING ONLY Made By: Spitwater Australia Pty Ltd 953 Metry St North Albury, NSW, Australia
More informationWeishaupt dual fuel burners Sizes 30 to 70 Version 1LN (NO X -reduction on gas operation) 1/2003 CA
Weishaupt dual fuel burners Sizes 30 to 70 Version 1LN (NO X -reduction on gas operation) 1/2003 CA Description Weishaupt burners of sizes 30 to 70 were specially designed and developed for industrial
More informationCapri B Cast iron combination oil-fired boiler with water tank
C 151-01 Cast iron combination oil-fired boiler with water tank Life-enhancing heat GB Cast iron combination oil-fired boiler with water tank RELIABILITY SAFETY EASY OPERATION EASE OF MAINTENANCE Life-enhancing
More informationColumbia Boiler Company
EMG Series Boilers Available in Natural Gas & Propane Rev 12012 Columbia Boiler Company PO Box 1070 Pottstown, PA 19464 Tel (610) 473-8457 Fax (610) 367-6800 Website www.columbiaboiler.com Email cbcsales@ptd.net
More informationMAINTENANCE AND SERVICE GUIDE
c Dimensions MAINTENANCE AND SERVICE GUIDE System II 80 and 100 Central Heating Fanned Flue Boiler Sizes in mm Flue types: C 12 or 42: horizontal C 32 xx: vertical concentric C 32 xy: Twin flue Boiler
More informationCapri R CH only, oil-fired, cast iron boiler
C 153-01 CH only, oil-fired, cast iron boiler Life-enhancing heat GB CH only, oil-fired, cast iron boiler RELIABILITY SAFETY EASY TO OPERATE EASE OF MAINTENANCE Life-enhancing heat CAPRI R range includes
More informationPARAFFIN/DIESEL HEATERS
INSTRUCTIONS FOR: PARAFFIN/DIESEL HEATERS Models: AB602, AB902, AB801, AB80, AB100X & AB160X Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according
More informationPEGASUS F2 N 2S. CAST IRON GAS BOILER for heating with electronic ignition and flame control INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE
PEGASUS F2 N 2S CAST IRON GAS BOILER for heating with electronic ignition and flame control INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE cod. 3544309/0 ediz. 01/2003 Carefully read the warnings in
More informationINSTALLATION AND OPERATION MANUAL
INSTALLATION AND OPERATION MANUAL PRESSURISED STEEL BOILERS AR 30 AR 1000 RADIALAND - BOILER's INSTALLATION MANUAL version 1.0 / 15-02-2008 The company E. is outstanding in the field of central heating
More informationOPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS
OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-200 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA B140.02003
More informationIndirect gas-fired air heater
Indirect gas-fired air heater SERIES HD INSTALLATION AND SERVICE MANUAL MANUFACTURED BY : BROTHERS LIMITED WARNING Improper installation, modification, adjustment or maintenance may cause damage, injury
More informationINSTRUCTION MANUAL AIR HEATER TYPE HEAT-X
INSTRUCTION MANUAL AIR HEATER TYPE HEAT-X GB 0g THIS DOCUMENT MUST ABSOLUTELY BE READ BEFORE STARTING THE INSTALLATION. INSTRUCT USER AND LEAVE THIS DOCUMENT WITH THE HEATER FOR REFERENCE. Instruction
More informationW - WR - WD. Technical information W- WR - WD. Gas-fired convection heaters with fan
Gas-fired convection heaters with fan W - WR - WD Technical information A2B srl - Via d Ancona, 37-60027 Osimo (An) Tel. 071.723991 - Fax 071.7133153 - Web Site: www.accorroni.it - E-mail: a2b@a-2-b.it
More informationIDEA SERIES LIGHT OIL BURNERS LO280 LO400
IDEA SERIES LIGHT OIL BURNERS LO280 LO400 MANUAL OF INSTALLATION - USE - MAINTENANCE Complying with EMC 79/336/CEE LV 73/23/CEE C.I.B. UNIGAS spa - Campodarsego (Padova - Italy) M039134CC Rev. 2 05-08
More informationRL 70/2-100/2-130/2 Low - High Operation
Installation, use and maintenance instructions Light Oil Burners RL 70/2-100/2-130/2 Low - High Operation C6505052 CONTENTS WARNING TECHNICAL DATA............................. page 3 Burner models.....................................
More informationA AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1
A AD Oil burners fuel unit deltapumps.com DE116-0709 A-AD_en_0709.pdf - 16.11.09 Page 1/1 Oil burners fuel unit Type A, AD 1- Applications The DELTA aluminium fuel unit type A is an efficient and modern
More informationen Direct oil-fired space heaters HD... Operator's manual
0211670en 002 12.2007 Direct oil-fired space heaters HD... Operator's manual Table of contents 1. Foreword 5 2. Safety information 6 2.1 General recommendations... 6 2.2 Safety devices... 7 2.3 Labels...
More informationInstallation & Maintenance Manual
Installation & Maintenance Manual Series NG fully automatic gas burner Models NG125/NG150 : High/Low Gas Burner 11/12 Tel: +44 (0) 1905 794331 Fax: +44 (0) 1905 794017 Email: info@nu-way.co.uk Web: www.nu-way.co.uk
More informationInstallation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing
Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing Important: To protect the unit and avoid damage to the heat exchanger, the blower speed
More informationOPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS
OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA B140.02003
More informationINSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20
INSTALLATION, OPERATION AND MAINTENANCE Ariterm Hybrid 20 TABLE OF CONTENTS General...3 Installation... 4-5 Dimensions - with flue gas exhauster...6 Dimensions - without flue gas exhauster...7 Pipe installations...8
More informationINSTALLATION AND OPERATING INSTRUCTIONS JAKA HFD JAKA HFS
INSTALLATION AND OPERATING INSTRUCTIONS JAKA HFD JAKA HFS CGM-04/392 ER-0170/1996 Thank you for choosing a DOMUSA TEKNIK heating boiler. You have chosen a boiler which will provide the ideal level of comfort
More informationUniversal oil burner G
Technical Information Installation Instructions July 2009 edition In the interests of continuous product improvement, technical specifications are subject to change without prior notice! Universal oil
More informationWARNING. Keep area around vent terminal free of snow, ice, and debris.
Information contained in this manual pertains to direct vent boilers equipped with manufacturer installed blocked vent safety control system (pressure switch).! WARNING Installations of venting shall be
More informationExternal Module Floor Standing Condensing Oil Boiler Range ADDENDUM ATTENTION INSTALLERS - UPDATED INFORMATION!
Grant Vortex Pro External Module Floor Standing Condensing Oil Boiler Range ADDENDUM ATTENTION INSTALLERS - UPDATED INFORMATION! LOW Nox yellow flame (riello rdb 2.2 bx) burner fitted The Grant Vortex
More information10.1 Troubleshooting Condition Table
10.1 Troubleshooting Condition Table Behavior 01. The furnace does not operate when you set the wall thermostat to a high temperature. Component 1. Wall T-Stat (See Section 10.3) 2. Blower/Fan Limit (See
More informationEURO-OIL SERIES TYPES G.. G../. OR.. OR../. F.. FR..
EURO-OIL SERIES TYPES G.. G../. OR.. OR../. F.. FR.. AUTOMATIC OIL BURNER CONTROL SYSTEMS APPLICATION This range of electronic oil burner controls has been specifically designed for oil burners for non
More informationVICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power
VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 is the new wall-hung condensing boiler for room heating only, set-up for independent functioning and for that in cascade mode
More information