Air treatment guide. Adsorption Dryers

Size: px
Start display at page:

Download "Air treatment guide. Adsorption Dryers"

Transcription

1 Air treatment guide Dryers

2 Pneumatech Air Treatment Contents Compressed Air Treatment 4 Compressed Air Drying 6 Types of compressed air dryers 8 perating Principle 1 Features and benefits explained Compressed Air Purity 22

3 Compressed Air Treatment Untreated compressed air always contains contaminants because of the nature of the gas and how it is produced. The need for air treatment basically results from 3 characteristics of compressed air. Compressed air is always wet Compressed air is always contaminated Compressed air composes of other gases Contaminants Liquid water - water aerosols - water vapor Contaminants Liquid oil - oil aerosols - oil vapor Dirt - microorganisms - pipescale Trace gases: carbon monoxide, sulfur dioxide, nitrous oxide Contaminants xygen: contaminant if oxidation is unwanted Nitrogen: contaminant if oxidation is wanted How are the contaminants formed? As water is incompressible, the amount of moisture per m³ increases when air is compressed. The maximum amount of moisture per m³ air 1 is however limited for a certain temperature. Condensation will thus be formed when air is compressed. Vapour Vapour How are the contaminants formed? Added by the compressor installation through oil lubricated compressors (oil), adsorption dryers and activated carbon filters (dirt), piping network and vessels (pipescale). Trash in, trash out: oil vapors from car exhausts and industrial processes, atmospheric dirt and microorganisms get sucked in by the compressor. As with water, their concentration and thus importance increases significantly after compression. How are the contaminants formed? Dry air is mainly composed of nitrogen (78%) and oxygen (21%). Air will keep the same nitrogen/oxygen ratio after compression, so additional treatment is needed to change this gas mix. Carbon dioxide.3% C 2 ther gases.1% ther gases Compression Liquid 8 m 3 ambient air 1 m 3 compressed air at 7 bar(e) Compressor ² xygen 2.95% N 2 Nitrogen 78.8% Ar Argon.93% What problems can the contaminants cause? Corrosion of pipe lines Bad quality of the end product Malfunctioning of controls Build-up of ice Cultivation of micro-organisms What problems can the contaminants cause? Damaged production equipment, leading to inefficiencies and increased costs Air pollution, creating unhealthy work environments Pollution of the condensate What problems can the contaminants cause? xygen causes oxidation, leading to explosions or fire of flammables (fast oxidation) or to rotting processes and corrosion of metals (slow oxidation). Nitrogen is an inert gas that can prevent oxidation to happen. The Pneumatech solution The Pneumatech solution The Pneumatech solution Water separators Drains Refrigeration dryers dryers il coalescing filters il vapor filters Particulate filters il-water separators Breathing air units PSA nitrogen generators Membrane nitrogen generators PSA oxygen generators 4 dryers dryers 5

4 Compressed Air Drying Moisture is a fundamental element of atmospheric air, where it is present in the form of water vapor. The maximum moisture holding capacity of air (the maximum amount of moisture air can hold per m³ / ft³) is limited for a certain temperature; and increases as the temperature increases. At and above this line the air is 1% saturated (relative humidity of 1%), meaning that the excess moisture will condense as liquid water, and will in cold environments even transform to ice. Water content G/M3 As it is not possible to compress water, the moisture content of compressed air increases in relation to the pressure of the compressed air. As a result the moisture content will exceed the maximum moisture holding capacity of air (which is only dependent on temperature) and the excess amount of moisture will condense into liquid water. We can thus state that compressed air will normally always be 1% saturated Water Content v/s Temperature Curve Temperature o F % relative humidity ,1,9,8,7,6,5,4,3 6%,2 relative humidity,1 1 2 Water content Z/FT3 Temperature o C The saturated, hot air at the outlet of the compressor typically 8 C/ 176 F will cool down along the cold piping network to around ambient temperature. This causes condensate to form that can result in the a number of problems: Corrosion in pipe Bad product quality Process malfunctioning Bacterial environments Ice formation D YU KNW THAT? For every 12 C/ 22 F increase in air temperature the maximum water holding capacity doubles. In other words: saturated air at 3 C/ 86 F holds twice as many water than saturated air at 18 C/ 64 F. In order to avoid any of these things from happening compressed air dryers need to be added to your compressed air network. Dryers remove moisture to well below the saturation point, so that no condensation can be formed downstream. This in contrast to coolers, which also remove moisture by cooling the air but where the air always remains 1% saturated at the outlet. The required degree of dryness is usually expressed with the term dew point temperature. It is the temperature at which condensation (dew) occurs. A lower dew point temperature means a lower presence of moisture in the air. For compressed air applications the term Pressure Dew Point (PDP) is used. It is the temperature at which water vapor condenses into water at the current working pressure, and corresponds thus to the amount of moisture air can hold per m³ / ft³ compressed air. Note: There is a substantial difference between Atmospheric Dew Point (ADP) and PDP, as can be seen from the example below: What is the Atmospheric Dew point (ADP), when you have a Pressure Dew Point (PDP) of +3 C / 37.4 F at a pressure of 7 bar(g) / 12 psi(g) or 8 Bar(a)/ 116 psi(a)? A PDP of +3 C /37.4 F corresponds to a water content of 5.94 g per m 3 compressed air. If the air got expanded to atmosphere, the same moisture content got spread over 8 m 3. The corresponding moisture holding capacity is 8 times lower: 5.94 g/m 3 / 8 =,74 g/m 3, which equals an Atmospheric Dew Point (ADP) of -22 C/ -7.6 F 6 dryers dryers 7

5 Types of compressed air dryers Refrigeration dryers Refrigeration dryers are used for PDPs between +3 C/37.4 F to +1 C/5 F with the freezing point of water ( C/ 32 F) as the lower limit. By cooling the compressed air with a closed refrigeration system a large amount of water condenses and can be separated. Afterwards the compressed air is reheated with the incoming air to around room temperature. In this way the moisture content of the air stays well below the maximum moisture holding capacity at normal (nonfreezing) ambient temperatures, meaning that the relative humidity stays below 1%. It is recommended to stay below 5% relative humidity to avoid any condensation to happen on local cold spots of the piping network. Refrigeration Cycle Smart steering of the refrigerant compressor via intelligent control algorithms can significantly reduce the power consumption of modern refrigeration dryers. Refrigeration dryers are mainly suitable for compressed air applications with standard dry air demands; and are mostly installed as central protection in the compressor room. They provide the right air dryness for pneumatic AD refrigeration dryers tools, blast air and instrument air; and for a frost-free piping and distribution system. For critical applications and applications below 5 C/ 41 F ambient temperature, an adsorption dryer is recommended. Please consult the Pneumatech Refrigeration dryer catalogue for further information. AC refrigeration dryers Temperature o F ,6 5,5 Water content G/M ,4,3,2,1 Water content Z/FT Temperature o C dryers dryers are used when PDPs from -1 C/14 F down to -7 C/-94 F are to be achieved. They make use of a material which has a high affinity to attract moisture, so called hygroscopic material or desiccant. The adsorption of moisture causes the desiccant to be gradually saturated with water. PH heatless adsorption dryers PE heated purge adsorption dryers PB blower purge adsorption dryers Cycle Temperature o F ,6 5,5 Water content G/M Heat of adsorption,4,3,2,1 Water content Z/FT Temperature o C Therefore, the desiccant needs to be regenerated regularly to regain its drying capacity. dryers are typically built with two drying vessels ( towers ) for that purpose: the first tower will dry the incoming compressed air while the second one is being regenerated. To ensure continuity, each vessel switches tasks when the other one is completely regenerated. Note: Dry air comes with a cost, both in terms of initial investment as well as running costs. The required dryness of the compressed air network should be chosen based on the largest compressed air consumers, while more critical applications can be covered with a low PDP dryer at point of use. As Pneumatech adsorption dryers exist in all possible sizes, they can be used both centralized (in the compressor room) and decentralized (close to the point-of-use), dependent on the needs. D YU KNW THAT? If compressed air with PDP of -7 C/-94 F is being supplied to a normal living room of 2m³ in volume, it will contain half a gram of water by weight inside it. 8 dryers dryers 9

6 perating Principle Dryers All materials can adsorb and desorb water, only the degree of adsorption is different per material. Desiccant used in adsorption dryers is specifically designed to adsorb moisture. Desiccants can release the water particles by adding some form of energy to them. This is called regeneration. Pneumatech adsorption dryers consist of two towers, both filled with desiccant, which alternatively operate in adsorption or regeneration cycle via a controlled switching mechanism. nce the desiccant is saturated in one vessel the process is reversed, and the second vessel starts adsorbing. The four types of adsorption dryers differ from each other in the way regeneration (and cooling) is done. D YU KNW THAT? ne desiccant granule contains more pores to capture water vapour than a football field contains blades of grass. The PB (ZP) dryer has the highest initial investment cost but the lowest life cycle cost, as can be seen in the following typical lifecycle cost calculations. Cost Initial investment Typical lifecycle cost calculation based on 876 running hours per year A Cost Y1 Cost Y2 Cost Y3 Cost Y4 Cost Y5 PH PE PB PB Zero purge C B Cost Initial investment Typical lifecycle cost calculation based on 4 running hours per year 1 Cost Y1 Cost Y2 Cost Y3 Cost Y4 Cost Y5 PH PE PB PB Zero purge 2 3 principle Drying phase PH Heatless Dryers by adding dry air: moisture is attracted to the dry purge air and separates /detaches from the desiccant. This is the Pressure Swing (PSA) principle. PE Heated Purge Dryers PB Blower Purge Dryers PB ZP Zero Purge Dryers by adding heat: heat causes the water molecules in the desiccant to vibrate, which triggers the reverse physical action of adsorption. The water retaining forces are broken, and water is discharged in the form of vapor. This is the Temperature Swing (TSA) principle. Compressed wet air is passed through one tower filled with dessicant from the bottom. The dessicant removes the moisture from the air as it travels upwards. The dry air leaves the dryer through a filter and is ready to be used in sensitive applications. A. Payback time PB versus PH less than 1 year B. Total cost: 6.5 times the initial investment after 5 years C. Total cost: 2 times the initial investment after 5 years The choice for PH, PE or PB is typically based on the following selection criteria. Choice for lowest investment cost Limited number of running hours Load time below 4 hours High humidity environments Highly polluted atmosphere Balance between lowest investment cost and lowest lifecycle cost Most efficient solution in case of high humidity environments or highly polluted atmosphere Customer requirement; e.g. in the semiconductor industry 1. Payback time PB versus PH slightly higher than 1 year 2. Total cost: 3.5 times the initial investment after 5 years 3. Total cost: 1.5 times the initial investment after 5 years Select PH Select PE Select PB (ZP) Choice for lowest lifecycle cost High number of running hours A. Heatless purge B. Heated purge C. Heated blower purge A. Heatless purge B. Heated purge C. Heated blower purge phase A small amount of dried air controlled via a small nozzle is passed to the regenarating tower.this is called purge air. A small amount of dried air controlled via a small nozzle is passed to the regenerating tower.this is called purge air. Purge air is heated and sent through the saturated dessicant forcing the moisture out from top to bottom. The blower takes ambient air and blows it over the external heater. The heated air is then sent through the saturated desiccant, forcing the adsorbed moisture out, from top to bottom. PH PE PB PB ZP NA 1. Cooling from purge: 2. Zero purge: 1. Cooling from purge 2. Zero purge Cooling phase After the heating, the hot tower desiccant is cooled. Cooling is done by expanding dry compressed air from the outlet of the adsorbing vessel over the hot reactivated tower, from top to bottom. After the heating, the hot tower desiccant is cooled. Cooling is done by sending air from the hot vessel over a cooler and back into the hot tower, from bottom to top. PE PB PB ZP Standard half-cycle time (if no energy saving control) 3-4 minutes regeneration 4 hours: 3 hours regeneration 1 hour cooling 2 seconds pressurization/ depressurization Energy consumption High purge consumption Medium purge consumption +heater Small purge consumption Blower + heater No purge consumption Blower + heater 1 dryers dryers 11

7 Features and benefits explained A. Advanced energy management systems ptimal control & monitoring A. Advanced energy management systems for lowest operating costs dryers are sized for full-load operation, with extra margin to cope with the aging effect of the desiccant. In reality full-load operating conditions will rarely occur, due to fluctuations in the demand, seasonal and meteorological fluctuations and over-specification of the entire compressed air system. Heatless 2. & cooling temperature control (for heat regenerated dryers only) (PE, PB) Temperature sensors at the bottom of the vessel constantly monitor the regeneration temperatures and will stop the regeneration cycle when the vessel has been properly regenerated. As a consequence, the heaters will be switched off irrespective of the pre-set cycle time 4 and the program will switch to the cooling step. After pressurization the tower will go in idle mode until the other tower has finished its adsorption cycle. It is clear that switching off the heaters will lead to significant energy savings. The same energy saving algorithm is implemented for the cooling cycle, resulting in additional energy savings. temperature reached Cooling Energy Saving temperature reached Cooling temperature reached Cooling temperature reached Cooling Energy Saving Heated by heat Cooling 3. Compressor load/unload synchronization (PH, PE, PB) by heat Cooling Pneumatech adsorption dryers use 4 smart measures to cope with this reality; resulting in tremendous energy savings. When the compressor switches off or goes in standby mode, no compressed air needs to be dried. By connecting a simple wire from the compressor to the compressor synchronization port of the dryer controller, the adsorption dryer will go in standby mode together with the compressor. No regeneration energy is required in the standby phase, leading to substantial energy savings. Compressor off or in unload condition Unload Compressor restarts delivery 1. Pressure Dew Point (PDP) control (PH, PE, PB) The PDP sensor constantly measures the pressure dew point (PDP) of the air leaving the drying tower. nce the pre-set time has elapsed, regeneration of the non-drying tower is stopped if the PDP temperature is below the set point. As a result, the number of regeneration cycles is reduced over the lifetime of the adsorption dryer, leading to significant energy savings. Additionally, varying Pressure Dew Point (PDP) requirements can easily be anticipated. When changing the PDP setting, e.g. from -4 C/-4 F to -3 C/ -22 F the energy saving mode will be extended, leading to additional energy savings. PDP below set point 4. Purge nozzle optimization (PH, PB) The purge nozzle guarantees that a small amount of dried air is passed into the regenerating tower, for the purpose of regeneration (heatless dryers and purge heated dryers) or cooling (purge and blower heated dryers) purposes. This nozzle has a fixed orifice. The higher the operating pressure, the higher the purge flow will be. This purge - and thus energy-loss - is however unwanted, especially considering that the required purge is lower at the higher pressure. Pneumatech offers optimized purge nozzles for higher pressure applications as standard with the PH55-31; and as option for all other PH variants and for PB dryers. Energy Saving Less purge flow energy savings Energy Saving Extension Energy Saving Energy Saving Extension PDP below set point 12 dryers Note: The maximal standby time is 24 hours for heat regenerated dryers and 4 hours for heatless dryers. This prevents the desiccant from capturing moisture for too long time, which would accelerate aging. 4 As long as the minimum regeneration time of 3 minutes has passed. This prevents the real regeneration temperature being confused with a temporary temperature increase. dryers 13

8 Features and benefits explained B. High-quality, high-efficient desiccant, selected for the right application Stable performance over the entire lifetime Guaranteed dry air Low maintenance costs B. High-quality, high-efficient desiccant, selected for the right application (PH, PE, PB) dryers can only be energy efficient if they contain premium desiccant material. The desiccant used in Pneumatech adsorption dryers is carefully selected from a wide range of European and North- American suppliers, based on following key selection criteria: 1. Crushing strength Desiccant is subject to continuous cyclic load. Due to this load, low-quality desiccant will easily break up resulting in small dust particles, hereby quickly losing its water attraction capabilities, blocking valves or clogging the downstream dust filter and silencer. Crush strength (N) Silica gel - NWR Silica gel - WR Activated alumina Molecular sieve 3. Lowest total cost of ownership We carefully balance initial capital investment with ongoing running cost. Silica gel has the highest adsorption capacity and is therefore used in heat regenerated adsorption dryers (PE & PB). In the dynamic operation conditions of heatless adsorption dryers (PH) only a small percentage of the total static adsorption capacity is used because of the relatively short cycle Used in Specific surface area Equilibrium capacity (25 C) times. The use of silica gel in the case of -4 C/-4 F PDP applications would increase the initial investment significantly, but would not bring any purge loss reduction or other benefits. Heatless adsorption dryers are therefore filled with activated alumina 3 which provide equal dew point requirements (-4 C/-4 F PDP) and energy efficiency at lower investment costs. Activated alumina Silica gel WR 5 Silica gel NWR Molecular sieves Heatless regenerated dryers (-4 C/-4 F PDP) Heat regenerated dryers (protective layer against liquid water) Heat regenerated dryers (-4 C/-4 F PDP) Heat & heatless regenerated dryers (-7 C/-94 F PDP) High air inlet temperatures PH PE PB PE PB PH PE PB 335 m²/g 65 m²/g 75 m²/g 75 m²/g 1 % RH: 5 wt.% 8 % RH: 27.5 wt.% 1 % RH: 4 wt.% 8 % RH: 39 wt.% 1 % RH: 6.5 wt.% 8 % RH: 4 wt.% Crush strength 26 N 1 N 229 N 55 N 1 % RH: 17 wt.% 8 % RH: 24 wt.% Pneumatech competitor 2. Water resistance Standard desiccant will degrade when it comes in contact with liquid water. Although a water separator should be installed upstream of an adsorption dryer, some water carry-over to the lower part of the adsorption dryer can never be excluded. All Pneumatech adsorption dryers are therefore equipped with water-resistant desiccant material in the bottom part of the vessel. Silica gel Not Water Resistant 4. The right desiccant for the right application Different desiccants have different levels of water attraction. The greater the attraction, the lower pressure dew point is possible. However, the greater the level of water attraction of the desiccant, the more purge is required to regenerate it. Therefore we use molecular sieves at the top of the vessels in our -7 C/-94 F variants, while using silica gel (heat regenerated) or activated alumina (heatless) in our -4 C/-4 F variants. Molecular sieves have the tendency to adsorb moisture at low relative humidity and have thus the best performance at the low PDPs. 5. Anti-aging effect Some desiccants show fantastic static performance, but have a bad dynamic performance; meaning that they degrade after a couple of months because of pressure, temperature or air humidity variations. Pneumatech adsorption dryers are not only equipped with the most durable desiccant material in the market, they are also overfilled to cope with this aging affect or with temporary overloads. Before After Silica gel Water Resistant Before After Adsorbed water (wt. %) RH (%) performance (%) jr. 1-3 jr. 2-6 jr. Pneumatech Silica gel - NWR 4 Pneumatech Silica gel - WR 5 Competitor 1 Competitor 2 Silica gel - NWR Silica gel - WR Activated alumina Molecular sieve Adsorbent lifetime 14 dryers ³Exception is the PH2-45 which makes use of molecular sieves. 4 NWR: non water resistant 5 WR: water resistant dryers 15

9 Features and benefits explained C. Minimized risk of crushed desiccant thanks to spring-loaded desiccant and sonic nozzles Stable performance over the entire lifetime Low maintenance costs C. Minimized risk of crushed desiccant thanks to spring-loaded desiccant and sonic nozzles (PH, PE, PB) A high air speed through the vessels of the adsorption dryer can have a detrimental effect, even on high-quality desiccant. D. Counter-current regeneration for optimal energy efficiency and guaranteed dry air (PH, PE, PB) Counter-current regeneration is regeneration from the top to the bottom of the vessel; meaning opposite to the drying direction. Counter-current regeneration saves approximately 5% in required regeneration energy compared to co-current regeneration (i.e. regeneration in the same direction as drying). The reason is simple: in an adsorption dryer, the bulk of the moisture is stored at the inlet side of the drying vessel. D. Counter-current regeneration Stable performance over the entire lifetime Guaranteed dry air Lower Air Speed Increased Air Speed Image Source: Pneumatech has built inherent protection measures into the design of its adsorption dryers: 1. The desiccant of the PH2-31 extruded profile dryers is springloaded, keeping the desiccant within the confined volume at all times. This is in contrast to loose desiccant filling which can move and thus crush the desiccant. 2. Sonic nozzles are delivered with welded vessel PHdryers (optional) and all PE- and PB-dryers. The sonic nozzle limits the air flow speed through the dryer to a safe level of maximum,25m/s /,8ft/s inside the vessels, so that no damage is caused to the desiccant. If for any reason more air is passing through the dryer, the pressure drop over the nozzle increases so dramatically that the air speed is limited again. During regeneration in a co-current way all this moisture will have to be transported through the entire vessel. Because the outlet end of the vessel is still relatively dry, the moisture that is transported from the bottom side will be re-adsorbed at the outlet and the regeneration air will leave the vessel hot but still dry. This means a loss of energy. In a counter-current regeneration, the regeneration air will always leave the vessel at the wet side, and will always be in equilibrium with the wet inlet side, i.e. completely saturated, transporting the maximum amount of moisture out of the vessel. In other words: every Joule of regeneration energy that is put into the vessel during regeneration is used to its full extent, which is not the case in a co-current regeneration. Counter-current regeneration is a guarantee of a good dewpoint performance of the dryer, whatever the working conditions are. Under severe working conditions (i.e. high ambient temperature or high humidity) the regeneration will inevitably be slower, both in co-current as in counter-current designs, and there is a risk that it is not completely finished within the regeneration time frame. In those cases, for a co-current regeneration dryer, the top layer (that is also the dewpoint determining layer) will remain wet. For a counter-current dryer it is the bottom layer that will remain wet, which will cause no problems at all for the dewpoint. Additionally, counter-current regeneration is the safest choice, as there is no risk of accidentally igniting oil polluted desiccant (at the bottom) with hot regeneration air (coming in from the top). Desiccant material can become polluted with oil, if inlet filters have not been serviced properly. 16 dryers Pressure drop over nozzle (m Bar) Flow through dryer (I/s) 3. Pneumatech vessels typically have larger diameters than the competition. This results in a lower air speed, therefore reducing the risk of desiccant crushing. D YU KNW THAT? High air speeds typically occur in the following situations: Wrong start up procedure: without pressurization of the dryer vessel Buffer vessel installed between compressor and dryer Installations with multiple compressors/dryers; not 1-to-1 setup Applications where air is used at low pressure after the dryer (e.g. pipe line drying) Installations with regular start/stop Applications with high fluctuating air demands Wrong selection of dryer size: too high air flow / too low working pressure Installations with standby compressor but no standby dryer, where dryer is only sized for standard load dryers 17

10 Features and benefits explained E. Robust vessel and piping design Stable performance over the entire lifetime Safe operation F. Highly reliable valve selection Stable performance over the entire lifetime Low maintenance costs G. Carefully selected silencers Lowest noise levels Safe operation H. Designed for transportability & mountability Easy handling I. High efficiency heaters E. Robust vessel and piping design (PH, PE, PB) All pressure vessels are made in Europe and are designed, manufactured and inspected according to recognized regulations and standards (ASME VIII div 1, ISPESL VSR). This ensures that all vessels are designed for continuous fatigue load from bar up to the design pressure for a minimum lifetime of 1 years. International approvals such as ASME (USA), CRN (Canada), ML (China), MM (Singapore), AS121 (Australia) are available on request. All piping is completely hot-dip galvanized and makes use of flanged connections for easy maintenance and maximum leak tightness. All piping is sufficiently sized to ensure low pressure drop and maximum energy efficiency. G. Carefully selected silencers guarantee high energy efficiency, low noise levels and maximum safety (PH, PE, PB) The pressure drop over the silencer (and by extension the entire exhaust system including valves) has an important influence on the purge rate; and therefore the energy efficiency of the adsorption dryer. 1mbar / 1.45 PSI additional pressure drop over the silencer results in 8% increase in purge loss! Thanks to their up-sized silencers with advanced mufflers, Pneumatech adsorption dryers have the ideal balance between noise level reduction and energy efficiency. Note: In order to avoid inefficient operation, the Purelogic TM controller gives a service warning when the regeneration pressure drop exceeds 25 mbar/ 3.63 PSI. To guarantee safety, all silencers are designed for 1% working pressure and are equipped with integrated safety valves which open when the silencers get clogged. I. Heaters: High efficiency and maximum safety (for heat regenerated dryers only) (PE, PB) The heater is integrated in an insulated heater pipe to avoid energy losses. The heater can easily be accessed for maintenance without any height restriction for disassembly, this is in contrast to heaters integrated in the vessels. Furthermore, the heaters are designed for maximum lifetime and minimal risk: The heaters are made out of stainless steel and integrated in a nickel-plated heater pipe, to protect against corrosion. Large heaters are selected with a relatively low heat density (W/cm²) to guarantee the longest lifetime. They are equipped with a mechanical thermostat. This thermostat interrupts the electrical current through the heater when the temperature gets too high. If the heater becomes damaged, the heatless backup mode can be activated, a simplified sequence with only purge cooling as regeneration step and with adapted timing settings. Note: ptionally the vessels can also be insulated for further increase of the overall efficiency. Safe operation J. Compact, efficient and reliable side channel centrifugal blowers Low maintenance costs F. Highly reliable valve selection (PH, PE, PB) The vessel designs are equipped with reliable two-way carbon steel butterfly valves, with stainless steel disks. The valves are individually controlled by a pneumatic actuator. This avoids high torque requirements on the actuators. Note: Dust release is inevitable for adsorption dryers. dryer variants made out of extruded profile design have filter mats included in order to minimize dust release. However, it is recommended to replace the downstream filter cartridges once a year to avoid clogging. H. Designed for transportability & mountability (PH, PE, PB) All dryers feature forklift slots and lifting eyes for easy handling. The lifting eyes are designed to carry the full dryer weight. The center of gravity has been carefully considered during the design phase to avoid any risk of tilting during transportation. J. Blower: Compact, efficient and reliable side channel centrifugal blowers (for blower purge dryers only) (PB) For the PB dryers a blower is used to transfer the atmospheric air over the external heater to the saturated desiccant during the regeneration phase of PB dryers. For PB Zero Purge dryers the blower is also used during the cooling phase. To ensure the lowest life cycle cost, Pneumatech has opted for a side-channel centrifugal blower. This does not only result in a high efficiency level, it also guarantees maintenance-free operation for more than 24, operating hours. Each valve of the large PB range is equipped with limit switches, which return an alarm to the Purelogic TM controller in the unlikely event that a valve does not open or close. Note: In case of loss of supply voltage the regeneration valves will close down but the active vessel will continue to supply high-purity air to the downstream network. To minimize the total unit height, all flange connections are integrated into the top and bottom shells of the vessels. The side-channel principle makes the blower very compact and silent. The motors comply with DIN EN 634 and have IP 55 protection. The blowers are also UL/CSA approved and can be used without further testing all over the world. 18 dryers dryers 19

11 Features and benefits explained K. Purelogic controller Stable performance over the entire lifetime Guaranteed dry air Safe operation ptimal control & monitoring K. Purelogic TM controller The Purelogic controller ensures increased reliability, lowest operating costs and optimal control and monitoring of the dryer. 1. User-friendly interface The Purelogic controller incorporates a 3.5 inch highdefinition color display with a multilingual user interface and clear icon indications. It is always provided within an IP54 protected cabinet. IP65 protected cabinets are also available on certain variants as an option. The keyboard is durable to resist tough treatment in demanding environments. 3. The Purelogic controller incorporates all energy management systems described in section A of the Features and benefits chapter: Pressure Dew Point control, regeneration & cooling temperature control and compressor load/unload synchronization. Each function is clearly indicated through pictograms and LED indicators. All set-points can be easily altered through the user friendly interface. 4. ptimal control and monitoring The Purelogic can communicate with industrial protocols such as Modbus, Profibus or Ethernet/IP. Visualization via Ethernet/IP can be easily achieved by connecting the Ethernet port of the Purelogic to the local area network and then entering the corresponding IP address into your web browser. A screen shot of this is shown below. Additionally the Purelogic features remote start/stop capabilities. 2. Increased reliability The Purelogic ensures safe and reliable operation by monitoring pressures, temperatures and digital switches. Warning and alarm levels are set for each of these parameters, as are service indicators. This ensures the customer can react to these warnings before any losses to production. 2 dryers dryers 21

12 Compressed air purity Compressor Water separator Coalescing filter general protection Coalescing filter high efficiency dryer Activated carbon tower Particulate filter general protection Particulate filter high efficiency IS8573-1:21 class Product + Contaminant Water aerosol il aerosol & wet dust il aerosol & wet dust Water vapor il vapor Dry dust Dry dust Solid Water Total oil Pneumatech reference il-injected il-free without oil vapors at inlet il-free with oil vapors at inlet SW G C PB/PE/PH VT/V S D At different points of use, different compressed air purities might be needed, depending on the application. IS8573-1:21 is the latest international standard for compressed air purity specification and defines purity classes for compressed air with respect to solid particles, water and oil. The table specifies which IS8573-1:21 purity classes are reached for certain combinations of Pneumatech adsorption dryers and filters. General guidelines You always need to install a water separating device in front of a coalescing filter. This can be either a freestanding version (SW) or an integrated water separating device in the after cooler. You always need to install a dryer in front of an oil vapor removal filter (VT/V). It is recommended to install a G - C combination in front of an adsorption dryer, in case of oilinjected compressors. It is recommended to install an additional P pre-filter upstream the G filter in case of heavy contamination. In case of critical applications, it is better to install air treatment products at point of use, in order to make sure that pipeline contamination is removed. IS8573-1:21 purity classes Solid particles Water Total il* Purity Class Number of particles per m³ Pressure dewpoint Concentration.1< d.5μm**.5 < d 1.μm** 1. < d 5.μm** C F mg/m³ As specified by the equipment user or supplier and more stringent than Class mg/m³ 1 5 * Liquid, aerosol and vapor ** d= diameter of the particle 22 dryers dryers 23

13 Pneumatech reserves the right to change or revise specifications and product design in connection with any features of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. 217 Pneumatech. All rights reserved. LLYD S REGISTER LRQA IS 91 - IS 141 HSAS 181

Product Catalogue Edition 1

Product Catalogue Edition 1 Product Catalogue 2018 Edition 1 Pneumatech Air Treatment Contents Adsorption Dryers... 7 PH 2-45 - Extruded profile heatless adsorption dryers...8 PH 55-550 - Extruded profile heatless adsorption dryers...10

More information

DESICCANT AIR DRYERS. BD + CD + CD series

DESICCANT AIR DRYERS. BD + CD + CD series DESICCANT AIR DRYERS BD + CD + CD series AIR TREATMENT, A CRUCIAL INVESTMENT WHY YOU NEED QUALITY AIR Compressed air contains oil, solid particles and water vapors. Together, they form an abrasive, often

More information

DESICCANT AIR DRYERS. BD + CD + CD series

DESICCANT AIR DRYERS. BD + CD + CD series DESICCANT AIR DRYERS BD + CD + CD series AIR TREATMENT, A CRUCIAL INVESTMENT WHY YOU NEED QUALITY AIR Compressed air contains oil, solid particles and water vapors. Together, they form an abrasive, often

More information

DESICCANT AIR DRYERS FOR SUPERIOR PRODUCTIVITY

DESICCANT AIR DRYERS FOR SUPERIOR PRODUCTIVITY DESICCANT AIR DRYERS FOR SUPERIOR PRODUCTIVITY CD+ series (500 l/s, 5968 cfm) BD+ series (00000 l/s, 660 cfm) XD+ series (550600 l/s, 65768 cfm) COMPLETE PROTECTION FOR YOUR APPLICATION Dry and clean compressed

More information

Refrigerant air dryers. FD series ( l/s, cfm)

Refrigerant air dryers. FD series ( l/s, cfm) Refrigerant air dryers FD series (6-4000 l/s, 13-8480 cfm) Why dry your compressed air? Compressed air is used in a wide variety of industrial applications. Wherever it is used, compressed air must be

More information

Atlas Copco. Heat-of-compression rotary drum dryers ND series ( l/s, cfm)

Atlas Copco. Heat-of-compression rotary drum dryers ND series ( l/s, cfm) Atlas Copco Heat-of-compression rotary drum dryers ND series (1000-2500 l/s, 2290-5297 cfm) Cost-effective dry air for your application Dry and clean compressed air is essential for a broad range of industrial

More information

Chapter 9: The basics of air preparation

Chapter 9: The basics of air preparation Right of authorship: the content of the training (wording, drawings, pictures) are owned by the author. Any utilization except for individual use is allowed only after permission of the author. Compressed

More information

TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION

TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION Having an understanding of why water forms in your compressed air piping system will help you in evaluating the type of air drying system

More information

White paper Compressed air drying

White paper Compressed air drying White paper Compressed air drying White paper : Compressed air drying Table of content Introduction 4 Where does the water come from? 5 How to remove the water? 6 Drying methods 7 Refrigerant dryers 8

More information

Adsorption Air Dryers

Adsorption Air Dryers Adsorption Air Dryers ADS 1 to 215 Clean and dry air. Prevent the risks, enjoy the benefits. AVAILABILITY PARTNERSHIP SERVICEABILITY TECHNOLOGY YOU CAN TRUST RELIABILITY SIMPLICITY AVAILABILITY PARTNERSHIP

More information

pneudri modular dessicant dryer

pneudri modular dessicant dryer Distributors For: Branch Directory: 149 Glasgow Road Wishaw Lanarkshire ML2 7QJ Tel 01698 355711 Fax 01698 359299 Wellheads Road Farburn Industrial Estate Dyce, Aberdeen AB21 7HG Tel 01224 723434 Fax 01224

More information

Moisture can be very disruptive to a dust. Preventing moisture problems in your dust collector

Moisture can be very disruptive to a dust. Preventing moisture problems in your dust collector As appeared in March 2017 PBE Copyright CSC Publishing www.powderbulk.com Preventing moisture problems in your dust collector Brian Mathews Scientific Dust Collectors This article discusses how moisture

More information

Pneumatech: Your guarantee of highquality. air and gas

Pneumatech: Your guarantee of highquality. air and gas Pure air Pure gas Pneumatech: Your guarantee of highquality compressed air and gas Automotive Textile Power Generation General Industry Oil & Gas Food & Beverage Electronics Since 1966, Pneumatech has

More information

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products Smart Solutions for Drying Compressed Air Single Tower Heat Reactivated Desiccant Air Dryer TM HS Dryer 800.943.794 www.engineeredairproducts.com Engineered Air Products Understanding Compressed Air Moisture

More information

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products Smart Solutions for Drying Compressed Air Single Tower Heat Reactivated Desiccant Air Dryer TM HS Dryer 800.943.794 www.engineeredairproducts.com Engineered Air Products Moisture in compressed air is damaging.

More information

Adsorption Dryers. AD 7 to 1300

Adsorption Dryers. AD 7 to 1300 D dsorption Dryers D 7 to 300 LUP Driven by technology. Designed by experience. lup Kompressoren has over 85 years of industrial experience. It is our ambition to offer compressed air solutions that ensure

More information

High quality compressed air from generation to application

High quality compressed air from generation to application 01 02 Introduction High quality compressed air from generation to application aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing &

More information

Adsorption Dryers for Compressed Air

Adsorption Dryers for Compressed Air Adsorption Dryers for Compressed Air ADS 1 to 215 Clean and dry air. Prevent the risks, enjoy the benefits. AVAILABILITY PARTNERSHIP SERVICEABILITY TECHNOLOGY YOU CAN TRUST RELIABILITY SIMPLICITY AVAILABILITY

More information

Heatless Regenerative Compressed Air Dryers. Compressed Air System Products. Made in America

Heatless Regenerative Compressed Air Dryers. Compressed Air System Products. Made in America Heatless Regenerative Compressed Air Dryers Compressed Air System Products Made in America 22 AIR/TAK Heatless Regenerative Air Dryers Compressed Air System Products That Save Energy & Improve Operations.

More information

clean, dry compressed air

clean, dry compressed air clean, dry compressed air Adsorption Air Dryers Air and gas purification have been at the core of Xebec adsorption technology since 1967. We have built, installed and continue to service over 9000 dryers.

More information

Industrial Oxygen Generation Plant

Industrial Oxygen Generation Plant Industrial Oxygen Generation Plant Operation Process Description : (Ref: P-I Diagram) Oxygen is generated from Compressed air by a separation process which uses the principle of selective adsorption. The

More information

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax A R R O W P N E U M A T I C S Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca. 93308 661-399-9569 fax 661-393-9654 F I L T E R S R E G U L A T O R S L U B R I C A T O R S A C C E S S O R I E S H E

More information

A-DRY Heatless adsorption compressed air dryers

A-DRY Heatless adsorption compressed air dryers A-DRY 6-05 Heatless adsorption compressed air dryers A-Dry - Adsorption compressed air dryer Four individually controlled valves To provide optimum control over the complete drying process four high quality

More information

Single Tower Heat Reactivated Desiccant Air Dryer

Single Tower Heat Reactivated Desiccant Air Dryer Single Tower Heat Reactivated Desiccant Air Dryer iste Dryer Understanding Compressed Air Moisture in compressed air is damaging. Using untreated air results in water and contaminants in your air lines,

More information

ADSORPTION DRYING: WHY?

ADSORPTION DRYING: WHY? ADSORPTION DRYERDB ADSORPTION DRYING: WHY? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated as there

More information

Dual Tower Heat Reactivated Desiccant Air Dryer

Dual Tower Heat Reactivated Desiccant Air Dryer Dual Tower Heat Reactivated Desiccant Air Dryer idhpe Dryer idbpe Dryer Eliminate Water from Your Compressed Air System Moisture in compressed air is damaging. Without proper treatment, this vital energy

More information

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page 150-3,000 scfm AEHD Series Desiccant Air Dryers AEHD Series Externally Heated Desiccant Air Dryer 150-3,000 scfm Front Page 1 AEHD Series Heated Dryer Externally Heated Desiccant Dryer 150-3,000 scfm Since

More information

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer Smart Solutions for Drying Compressed Air Dual Tower Heat Reactivated Desiccant Air Dryer HR Heated HB Blower 800.943.794 www.engineeredairproducts.com Engineered Air Products Moisture in compressed air

More information

High Efficiency Compressed Air Dryers. Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY

High Efficiency Compressed Air Dryers. Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY High Efficiency Compressed Air Dryers Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY Adsorption Dryers Modular System Compressed air purification equipment must deliver uncompromising performance

More information

SSB Blower Purge Desiccant Dryers SSE Heat Reactivated Desiccant Dryers 220 to 10,500 scfm

SSB Blower Purge Desiccant Dryers SSE Heat Reactivated Desiccant Dryers 220 to 10,500 scfm SSB Blower Purge Desiccant Dryers SSE Heat Reactivated Desiccant Dryers 220 to 10,500 scfm Dry air as low as -100 F pressure dew point Clean, dry compressed air solves the problems of moisture contamination

More information

PET Drying Technology

PET Drying Technology PET Drying Technology Introduction Industry s increasing demand for clean, reliable sources of high pressure compressed air require that system designers become more educated in dehydration and filtration

More information

High Efficiency Compressed Air Dryers. Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY

High Efficiency Compressed Air Dryers. Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY High Efficiency Compressed Air Dryers Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY Adsorption Dryers Modular System Compressed air purification equipment must deliver uncompromising performance

More information

Adsorption Dryers. AD 7 to 1300

Adsorption Dryers. AD 7 to 1300 AD Adsorption Dryers AD 7 to 1300 ALUP s heritage Founded in Germany in 1923, the company derives its name of the automotive products that were manufactured in the Köngen mechanical workshop where ALUP

More information

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration INNOVATIVE COMPRESSED AIR SOLUTIONS TM DESICCANT AIR DRYERS 90-8000 scfm ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration www.zeks.com RELIABLE PERFORMANCE. DESIGN INNOVATION.

More information

Desiccant Dryers. Desiccant Dryers. Heatless Heated Purge Blower Purge Modular

Desiccant Dryers. Desiccant Dryers. Heatless Heated Purge Blower Purge Modular Desiccant Dryers Desiccant Dryers Heatless Heated Purge Blower Purge Modular Desiccant Air Dryers Quincy desiccant air dryers purify compressed air by adsorbing water vapor. Pressure dewpoints of -40 F

More information

HEATLESS REGENERATIVE DRYERS

HEATLESS REGENERATIVE DRYERS HEATLESS REGENERATIVE DRYERS PHL SERIES Pioneer Air Systems Inc. 210, Flatfork Road, Wartburg, TN - 37887 Tel. : (423) 346-6693 Fax : (423) 346-3865, (423) 346-7522 Email : sales@pioneerair.com Internet

More information

CLEAN, DRY COMPRESSED AIR

CLEAN, DRY COMPRESSED AIR CLEAN, DRY COMPRESSED AIR Adsorption Air Dryers Air and gas purification have been at the core of Xebec adsorption technology since 1967. We have built, installed and continue to service over 9000 dryers.

More information

Membrane Dryers KMM Series

Membrane Dryers KMM Series www.kaeser.com Membrane Dryers KMM Series Flow volume at inlet up to.0 m /min Why is it necessary to dry compressed air? The atmospheric air drawn into a compressor is a mixture of gases that always contains

More information

ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr)

ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr) snowstorm filled ultra-high purity compressed air dryers flow capacity: 3-1110 scfm (5-1900 Nm 3 /hr) D 1 2 3 ultra-high purity compressed air dryers flow capacity: 3-1110 scfm (5-1900 Nm 3 /hr) D 1 2

More information

Regenerative Desiccant Dryers. KAD, KED, KBD and Hybritec Series

Regenerative Desiccant Dryers. KAD, KED, KBD and Hybritec Series Regenerative Desiccant Dryers KAD, KED, KBD and Hybritec Series The Right Dryer For You Most compressed air applications require only refrigerated dryers; however, if your compressed air is exposed to

More information

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr) D twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-1,300 Nm3/hr) D D D twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-1,300 Nm 3 /hr) Leading

More information

Desiccant Air Drying Technologies HCS Series HCL Series HCT Series

Desiccant Air Drying Technologies HCS Series HCL Series HCT Series Desiccant Air Drying Technologies HCS Series HCL Series HCT Series HCS, HCL and HCT Series Heatless Dryers Models 40-450 Models 590-5400 HCS, HCL and HCT Series Heatless Desiccant Dryers Since 1961, compressed

More information

Trident Breathing Air System

Trident Breathing Air System Trident Breathing Air System INSTALLATION, OPERATION, MAINTENANCE PSA Type Breathing Air Dryer Dealer: This manual MUST be given to the end user. User: BEFORE using this product, read this manual and preserve

More information

Modular Adsorption Dryers

Modular Adsorption Dryers 01 GB Modular Adsorption Dryers Highly efficient air treatment Innovative compressed air treatment A-Series Totally dry and clean air The A-Series modular compressed air dryers - a dedicated solution for

More information

Desiccant Dryers DC Series (Heatless regenerated) Air flow rates 0.15 to m³/min.

Desiccant Dryers DC Series (Heatless regenerated) Air flow rates 0.15 to m³/min. Desiccant Dryers DC Series (Heatless regenerated) Air flow rates.5 to 5.5 m³/min www.kaeser.com Why is it necessary to dry compressed air? The atmospheric air drawn into a compressor is a mixture of gases

More information

HEAT OF COMPRESSION DESICCANT AIR DRYERS. DHC Series

HEAT OF COMPRESSION DESICCANT AIR DRYERS. DHC Series HEAT OF COMPRESSION DESICCANT AIR DRYERS DHC Series Why Heat of Compression? The DHC Series heat of compression desiccant air dryers from Gardner Denver provide an energy efficient solution to remove moisture

More information

PNEUDRI High Efficiency Compressed Air Dryers.

PNEUDRI High Efficiency Compressed Air Dryers. PNEUDRI High Efficiency Compressed Air Dryers www.domnickhunter.com 1 PNEUDRI High Efficiency Compressed Air Dryers Compressed air plays an important role in modern industry. The decisions you make regarding

More information

Membrane Dryers KMM Series

Membrane Dryers KMM Series www.kaeser.com Membrane Dryers KMM Series Flow volume at inlet up to. m /min Why is it necessary to dry compressed air? The atmospheric air drawn into a compressor is a mixture of gases that always contains

More information

Downstream Equipment. Intelligent Air Technology

Downstream Equipment. Intelligent Air Technology Downstream Equipment Intelligent Air Technology The Clean Air Solution The advanced range of CompAir inline equipment has been specially developed to meet the needs of modern manufacturing and processing

More information

TWP & TWB Series Externally Heated and Blower Purge Desiccant Air Dryers

TWP & TWB Series Externally Heated and Blower Purge Desiccant Air Dryers TWP & TWB Series Externally Heated and Blower Purge Desiccant Air Dryers Parker Airtek Externally Heated and Blower Purge Desiccant Air Dryers use the adsorption method to remove moisture from compressed

More information

FACT SHEET 3. Efficient Compressed Air Treatment. How to save energy, reduce costs and help the environment

FACT SHEET 3. Efficient Compressed Air Treatment. How to save energy, reduce costs and help the environment FACT SHEET 3 How to save energy, reduce costs and help the environment COMPRESSED AIR TREATMENT All compressed air needs some form of treatment to achieve the desired air quality. This guide investigates

More information

HEATLESS DESICCANT AIR DRYERS

HEATLESS DESICCANT AIR DRYERS HEATLESS DESICCANT AIR DRYERS HHS, HHL AND HHE SERIES HANKISON HEATLESS DESICCANT DRYERS HHS, HHL AND HHE SERIES Since 1948, sensitive applications requiring clean, dry, compressed air have turned to Hankison

More information

PNEUDRI High Efficiency Compressed Air Dryers

PNEUDRI High Efficiency Compressed Air Dryers PNEUDRI High Efficiency Compressed Air Dryers www.domnickhunter.com 1 PNEUDRI High Efficiency Compressed Air Dryers Compressed air plays an important role in modern industry. The decisions you make regarding

More information

Adsorption Dryers. DB 05 to 130

Adsorption Dryers. DB 05 to 130 DB Adsorption Dryers DB 05 to 130 Worthington reyssensac s heritage reyssensac was founded in Nanterre (near Paris), France in 1934 by Elie reyssensac and quickly became renowned in the automotive industry

More information

DTA Series Heatless Adsorption Dryers ENGINEERING YOUR SUCCESS.

DTA Series Heatless Adsorption Dryers ENGINEERING YOUR SUCCESS. DTA Series Heatless Adsorption Dryers aerospace climate control electromechanical filtration liquid & gas handling hydraulics pneumatics process control sealing & shielding ENGINEERING YOUR SUCCESS. Compressed

More information

MANUAL. Dryspell INSTALLATION OPERATION MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

MANUAL. Dryspell INSTALLATION OPERATION MAINTENANCE. Regenerative Type Heatless Desiccant Dryer MANUAL INSTALLATION OPERATION MAINTENANCE Regenerative Type Heatless Desiccant Dryer Dryspell Contents 1. Introduction 2 1.1 Design 1.2 Relevant Units 1.3 Statement of Conformity 1.4 Description 1.5 Adsorbant

More information

Desiccant Air Dryers. ABP Series. Blower Purge Desiccant Air Dryer 70-8,000 scfm

Desiccant Air Dryers. ABP Series. Blower Purge Desiccant Air Dryer 70-8,000 scfm Desiccant Air Dryers ABP Series Blower Purge Desiccant Air Dryer 70-8,000 scfm Since 1994, Aircel has been delivering quality, industry leading compressed air dryers and accessories for production lines

More information

Global Leader in Efficiently Treating Compressed Air EXCELLENCE IN DESIGN, MANUFACTURING AND SERVICE

Global Leader in Efficiently Treating Compressed Air EXCELLENCE IN DESIGN, MANUFACTURING AND SERVICE Global Leader in Efficiently Treating Compressed Air EXCELLENCE IN DESIGN, MANUFACTURING AND SERVICE REFRIGERATED AIR DRYING TECHNOLOGIES HPR SERIES REFRIGERATED DRYERS Dry Compressed Air... Pure and Simple

More information

Ingersoll Rand. Heatless and Heated Blower Desiccant Air Dryers ,900 m 3 /hr

Ingersoll Rand. Heatless and Heated Blower Desiccant Air Dryers ,900 m 3 /hr Ingersoll Rand Heatless and Heated Blower Desiccant Air Dryers 160-14,900 m 3 /hr Innovative Design is Now Within Reach Ingersoll Rand Ingersoll Rand heatless and heated blower desiccant dryers are engineered

More information

High Inlet Temperature Air Dryer. Desiccant Air Dryer. Membrane Air Dryer After-Clooler. Air Filter. Oil-Water Separator Automatic Drain Value

High Inlet Temperature Air Dryer. Desiccant Air Dryer. Membrane Air Dryer After-Clooler. Air Filter. Oil-Water Separator Automatic Drain Value High Inlet Temperature Air Dryer Membrane Air Dryer After-Clooler Oil-Water Separator Automatic Value 1 2 3 4 5 6 7 8 9 1 HYD model Control Panel 1. on HYD-150 and smaller - It is equipped with a low pressure

More information

New standard in compressed air treatment, providing Energy Savings up to 99%

New standard in compressed air treatment, providing Energy Savings up to 99% PCM Series Specification for APAC Model Flow Capacity (Nm 3 /min) Pressure Dew Point ( ) Power Consumption (kw) Power Supply (V/Ph/Hz) Inlet/Outlet Connections Weight (kg) Dimensions (H x W x D mm) Refrigerants

More information

www.compressedairsystems.com PURIFICATION SOLUTIONS D-Series1 ultra-high purity compressed air dryers flow capacity: 3-177 scfm (5-301 Nm /hr) 3 D 1 D-Series 1 ultra-high purity compressed air dryers D

More information

Externally Heated Desiccant Air Dryer RP Series

Externally Heated Desiccant Air Dryer RP Series Externally Heated Desiccant Air Dryer RP Series Externally Heated Desiccant Compressed Air Dryers Reduce Purge Air Energy Costs For decades, compressed air users have relied on Deltechto deliver technology

More information

DGH Series Global Air Treatment

DGH Series Global Air Treatment DGH Series Global Air Treatment 2 DGH Desiccant Dryers Customizable Performance Gardner Denver DGH Series Heatless Desiccant Dryers were designed to help you meet your goals. Customizable performance technology

More information

Adsorption Air Dryers

Adsorption Air Dryers dsorption ir Dryers DS to Clean and dry air. Prevent the risks, enjoy the benefits. V PRTERSIP SERVICE TECOOG OU C TRUST REI SIMPIC V PRTERSIP SERVICE TECOOG OU C TRUST REI DS dsorption Dryers compressor

More information

Adsorption Compressed Air Dryer Heatless or heater regeneration

Adsorption Compressed Air Dryer Heatless or heater regeneration Adsorption Compressed Air Dryer Heatless or heater regeneration What s adsorption? Drying with high efficiency and economy Some compressed air applications requests a low moisture level (dew point between

More information

Desiccant Regenerative Dryers 3-10,000 scfm

Desiccant Regenerative Dryers 3-10,000 scfm Desiccant Regenerative Dryers 3-10,000 scfm Desiccant Modular Desiccant Heatless Desiccant Externally Heated Desiccant Blower Purge OWS - 210 Sullair Capabilities Sullair Leadership Since 1965, Sullair

More information

Atlas Copco Stationary Air Compressors. GA30-90C WorkPlace Air System TM 30-90kW/40-125HP oil-injected rotary screw compressors

Atlas Copco Stationary Air Compressors. GA30-90C WorkPlace Air System TM 30-90kW/40-125HP oil-injected rotary screw compressors Atlas Copco Stationary Air Compressors GA30-90C WorkPlace Air System TM 30-90kW/40-125HP oil-injected rotary screw compressors Introducing the WorkPlace Air System The only compressed air system that can

More information

Product Data Sheet Adsorption Dryer DPS

Product Data Sheet Adsorption Dryer DPS Version: 1.6.0 Author: Tassilo Tappe Date : 05.07.2016 Field of application Adsorption dryers of the DPS series are designed for drying compressed air and nitrogen to pressure dew points of -25 C to -70

More information

Atlas Copco. Oil-injected Rotary Screw Compressors GA 5-11/GA 5-15 VSD (5,5-11 kw/7,5-15 hp)

Atlas Copco. Oil-injected Rotary Screw Compressors GA 5-11/GA 5-15 VSD (5,5-11 kw/7,5-15 hp) Atlas Copco Oil-injected Rotary Screw Compressors GA 5-11/GA 5-15 VSD (5,5-11 kw/7,5-15 hp) The ultimate smart solution that fits Atlas Copco s GA compressors bring outstanding performance, flexible operation

More information

HIGH QUALITY COMPRESSED AIR FROM GENERATION TO APPLICATION A GUIDE TO THE ISO 8573 AND ISO SERIES OF COMPRESSED AIR QUALITY STANDARDS

HIGH QUALITY COMPRESSED AIR FROM GENERATION TO APPLICATION A GUIDE TO THE ISO 8573 AND ISO SERIES OF COMPRESSED AIR QUALITY STANDARDS HIGH QUALITY COMPRESSED AIR FROM GENERATION TO APPLICATION A GUIDE TO THE ISO 8573 AND ISO 12500 SERIES OF COMPRESSED AIR QUALITY STANDARDS CONTAMINATION > PARTICULATE TO UNDERSTAND THE NEED FOR AN INTERNATIONAL

More information

High Efficiency Compressed Air Dryers. Adsorption Dryers Classical System INTELLIGENT AIR TECHNOLOGY

High Efficiency Compressed Air Dryers. Adsorption Dryers Classical System INTELLIGENT AIR TECHNOLOGY High Efficiency Compressed Air Dryers Adsorption Dryers Classical System INTELLIGENT AIR TECHNOLOGY Heatless Regenerative Adsorption Dryers A18TX A930TX and A18TXA A157TXA Compressed air purification equipment

More information

Product Data Sheet Adsorption Dryer DPS (A)

Product Data Sheet Adsorption Dryer DPS (A) Version: 1.0.5 Author: Tassilo Tappe Date:13.07.2012 Field of application Adsorption dryers of the DPS series are designed for drying compressed air and nitrogen to pressure dew points of -25 C to -70

More information

Desiccant Dryers DC Series (Heatless regenerated) Air flow rates 0.15 to m³/min.

Desiccant Dryers DC Series (Heatless regenerated) Air flow rates 0.15 to m³/min. Desiccant Dryers DC Series (Heatless regenerated) Air flow rates 0.5 to 54.53 m³/min www.hpccompressors.co.uk Why is it necessary to dry compressed air? The atmospheric air drawn into a compressor is a

More information

HEATLESS REGENERATED ADSORPTION DRYER ULTRAPAC SMART

HEATLESS REGENERATED ADSORPTION DRYER ULTRAPAC SMART HEATLESS REGENERATED ADSORPTION DRYER ULTRAPAC SMART Ultrapac Smart Compressed air purification in three stages COMPRESSED AIR PURIFICATION IN THREE STAGES ECO Adsorption drying - why? Compressed air is

More information

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS INSTRUCTION MANUAL FOR WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS DE3 - DE5 OPERATIONS GENERAL This instruction manual covers the installation, operation, maintenance and troubleshooting

More information

Membrane Dryer. Air inflow rate KMM Series to m 3 /min

Membrane Dryer. Air inflow rate KMM Series to m 3 /min Membrane Dryer Air inflow rate KMM Series 0.08 to. m /min Why is it necessary to dry compressed air? The atmospheric air drawn into a compressor is a mixture of gases that always contains water vapour.

More information

Heatless Air Dryers AIRTEK PREMIUM PRODUCTS FOR INDUSTRY. TW Series

Heatless Air Dryers AIRTEK PREMIUM PRODUCTS FOR INDUSTRY. TW Series Heatless Air Dryers AIRTEK PREMIUM PRODUCTS FOR INDUSTRY TW Series Heatless Air Dryer Operation Airtek Heatless Dryers remove water vapor from compressed air through a process known as Pressure Swing Adsorption.

More information

AirCel. Heated Regenerative Desiccant Dryers. AEHD Externally Heated, HRE Blower Purge, and HRS-L Zero Purge Series

AirCel. Heated Regenerative Desiccant Dryers. AEHD Externally Heated, HRE Blower Purge, and HRS-L Zero Purge Series AirCel Heated Regenerative Desiccant Dryers AEHD Externally Heated, HRE Blower Purge, and HRS-L Zero Purge Series ié~çáåö=íüé=t~ó=áå=^áê=mìêáñáå~íáçå As one of the world s leading manufacturers of compressed

More information

Subfreezing Dryers SF Dryer, -20 C (-4 F) PDP

Subfreezing Dryers SF Dryer, -20 C (-4 F) PDP Subfreezing Dryers SF Dryer, -20 C (-4 F) PDP More Than 145 Years of Compressed Air Innovation Ingersoll Rand introduced its first air compressor in 1872. Over the next 145 years, we have continued to

More information

Heat Les Desiccant Compressed Air Dryers. DSE Series DSS Series DHD Series

Heat Les Desiccant Compressed Air Dryers. DSE Series DSS Series DHD Series Heat Les Desiccant Compressed Air Dryers DSE Series DSS Series DHD Series DSE, DSS and DHD Series Heat Les Desiccant Dryers For decades, compressed air users have relied on Pneumatic Products to deliver

More information

Atlas Copco. Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-15 kw/10-20 hp)

Atlas Copco. Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-15 kw/10-20 hp) Atlas Copco Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-15 kw/10-20 hp) Extreme savings No idling time Silent operation Small footprint The new revolutionary compressor from Atlas Copco

More information

Heat of Compression Desiccant Dryers: Clearing up the Confusion

Heat of Compression Desiccant Dryers: Clearing up the Confusion Heat of Compression Desiccant Dryers: Clearing up the Confusion Sponsored by Hank van Ormer, Air Power USA Keynote Speaker For your free subscription, please visit www.airbestpractices.com/magazine/subscription.

More information

Pressure Swing Desiccant Dryers

Pressure Swing Desiccant Dryers Pressure Swing Desiccant Dryers Featuring Legendary Heat-Les TM Technology The Original Heat Les Drying Technology The DHA / CDA series dryer has been designed specifically to bring you reliable performance

More information

HEAT REGENERATED ADSORPTION DRYERS

HEAT REGENERATED ADSORPTION DRYERS HEAT REGENERATED ADSORPTION DRYERS Clean Adsorption Drying The Importance of dry and clean Compressed Air In nearly all areas of the industry compressed air is one of the indispensable working medias.

More information

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 5-11 (5,5-11 kw/7,5-15 hp)

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 5-11 (5,5-11 kw/7,5-15 hp) OIL-INJECTED ROTARY SCREW COMPRESSORS GA 5- (5,5- kw/7,5- hp) Highest reliability THE ULTIMATE SMART SOLUTION THAT FITS Atlas Copco s GA compressors bring outstanding performance, flexible operation and

More information

Active Dry Air Venting for Water Contamination Control

Active Dry Air Venting for Water Contamination Control . PO Box 1299 Minneapolis, MN 5544 USA Industrial Hydraulics 1-8-846-1846 grphydfilters@donaldson.com Active Dry Air Venting for Contamination Control While required for biological life, water can be extremely

More information

V A C U U M A N D P R E S S U R E T E C H N O L O G Y

V A C U U M A N D P R E S S U R E T E C H N O L O G Y Medical Air System Totally Oil Free ULTRAAR Series 4 EN ISO 7396-1 / HTM 0201 220V - 400V / 50Hz 60Hz SPECIFICATION ULTRAAR The ULTRAAR Medical Air System Totally Oil Free shall conform to ISO 7396-1 and

More information

Instruction Manual Dry spell HFH INSTALLATION, OPERATION, MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

Instruction Manual Dry spell HFH INSTALLATION, OPERATION, MAINTENANCE. Regenerative Type Heatless Desiccant Dryer Adsorption dryer Instruction Manual Dry spell HFH INSTALLATION, OPERATION, MAINTENANCE Regenerative Type Heatless Desiccant Dryer WE REDEFINE COMPRESSED AIR TREATMENT SYSTEMS 5/232 KNG Pudur road, Somayampalayam

More information

CDT Series MCGUIRE AIR COMPRESSORS INC MCGUIRE AIR COMPRESSORS INC Heatless Desiccant Air Dryers 40 5,400 SCfm

CDT Series MCGUIRE AIR COMPRESSORS INC MCGUIRE AIR COMPRESSORS INC Heatless Desiccant Air Dryers 40 5,400 SCfm CDT Series Heatless Desiccant Air Dryers 40 5,400 SCfm ISO Quality Dew Points Three Controller Selection NEMA4 Electrical Construction Standard on Two Controllers Purge Optimal Savings 2 Personalized Performance

More information

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 5-11 (5,5-11 kw/7,5-15 hp)

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 5-11 (5,5-11 kw/7,5-15 hp) OIL-INJECTED ROTARY SCREW COMPRESSORS GA 5- (5,5- kw/7,5- hp) THE ULTIMATE SMART SOLUTION THAT FITS Atlas Copco s GA compressors bring outstanding performance, flexible operation and high productivity,

More information

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-37 VSD+ (7-37 kw/10-50 hp)

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-37 VSD+ (7-37 kw/10-50 hp) OIL-INJECTED ROTARY SCREW COMPRESSORS GA - VSD+ (- kw/- hp) Small compressor, big ideas Atlas Copco has turned the compressed air industry on its head by redesigning the conventional layout of a typical

More information

Compressed air preparation Compressed air storage Moisture management. Catalog #1

Compressed air preparation Compressed air storage Moisture management. Catalog #1 Compressed air preparation Compressed air storage Moisture management Catalog #1 This Catalogue is valid from May 2015. All previous catalogues lose their validity with the publication of the new catalogue.

More information

D-Series 2 D 3. ultra-high purity compressed air dryers. Flow Capacity: Nm 3 /hr ( scfm)

D-Series 2 D 3. ultra-high purity compressed air dryers. Flow Capacity: Nm 3 /hr ( scfm) -Series ultra-high purity compressed air dryers Flow Capacity: 5-1900 Nm 3 /hr (3-1110 scfm) 1 2 3 -Series ultra-high purity compressed air dryers Flow Capacity: 5-1900 Nm 3 /hr (3-1110 scfm) 1 2 3 nano-porous

More information

Spiralair SPR 2-30 TECHNOLOGY YOU CAN TRUST

Spiralair SPR 2-30 TECHNOLOGY YOU CAN TRUST Spiralair SPR 2-30 Oil-free compressors Industries such as pharmaceuticals, food and beverage, electronics and textiles cannot risk any chance of oil contamination in their processes. Therefore, it is

More information

Modular Adsorption Dryers

Modular Adsorption Dryers INDUSTRIALS GROUP Modular Adsorption Dryers Innovative compressed air treatment GDX Series GARDNER DENVER COMPRESSED AIR TECHNOLOGIES Compressed air dryers - The heart of the compressed air treatment solution

More information

Desiccant Air Dryers. Heatless, Heated and Heated Blower

Desiccant Air Dryers. Heatless, Heated and Heated Blower Desiccant Air Dryers Heatless, Heated and Heated Blower Desiccant Dryers... When we designed the Ingersoll Rand heatless, heated and heated blower desiccant dryers we set our sights on creating the most

More information

Thermo Scientific Model 1160 Principle of Operation

Thermo Scientific Model 1160 Principle of Operation Thermo Scientific Model 1160 Principle of Operation Thermo Scientific's Model 1160 Zero Air Supply converts ambient air to pollutant-free air. Table 1 describes the pollutants that can be removed, the

More information

Refrigeration Air Dryers ADQ. Capacity: m 3 /h

Refrigeration Air Dryers ADQ. Capacity: m 3 /h Refrigeration Air Dryers Capacity: 21-5040 m 3 /h Water Contamination in Compressed Air The water contained in a compressed air system will vary according to ambient conditions, i.e. temperature and humidity.

More information

Desiccant Drying DRYPOINT XC. efficient low dew point heatless desiccant drying. Truth in Compressed Air.

Desiccant Drying DRYPOINT XC. efficient low dew point heatless desiccant drying. Truth in Compressed Air. Desiccant Drying DRYPOINT XC efficient low dew point heatless desiccant drying Truth in Compressed Air. At a Glance DRYPOINT XC Heatless Desiccant Dryers Regenerative desiccant dryers are frequently found

More information