1 RAINFRESH CGFE GREENSAND FILTERS FOR REMOVAL OF IRON, MANGANESE & HYDROGEN SULFIDE Installation & operation instructions Thank you for purchasing one of our ENVIROGARD / Rainfresh Greensand Filter Systems. We are committed to ensuring that you are totally satisfied. If you have any problems, don t go back to the store please contact us! Most issues can be resolved over the phone. Help Line : Monday to Friday 8:30 AM to 5:00 PM EAST Website : TABLE OF CONTENTS System Specifications... 1 How The CGFE System Works... 2 Cautions Before Installation... 2 Installation... 3 a) Unpacking the unit b) Plumbing the Filter unit.. 4 c) Start-up and Programming... 5 Winterizing the System... 8 Troubleshooting... 8 Parts List... 9 Warranty... 9 SYSTEM SPECIFICATIONS: Model No. Rated Service Flow US GPM (LPM) Max Flow Rate US GPM (LPM) Backwash Flow Rate US GPM (LPM) Inlet / Outlet CGFE (8.3) 5 (19) 5 (19) 3/4" MNPT Drain Connection 1/2" Hose Electrical Requirement Pressure Drop 110V AC < 15 psig Operating Pressure psig Shipping Weight 140 lbs (63.5 Kg) Approx Potassium Permanganate (Pot-Perm) used per regeneration : lbs (56 g) Water Temp 4-38 C ( F) Water ph Range 6.5 to 8.5* Max Raw Water Turbidity 5 NTU *- higher the ph, better the performance Max Raw Water Iron+Manganese 15 PPM Max Raw Water Hydrogen Sulphide 5 PPM Oil in Water Nil
2 HOW THE CGFE SYSTEM WORKS Your Rainfresh CGFE filter utilizes oxidation and filtration technology to remove dissolved Iron, Manganese and Hydrogen Sulphide from water. Rainfresh Greensand Filter is based on the technology of oxidation and filtration. It incorporates a special high-oxidant media called Manganese Greensand. When water flows through the Greensand filter system, dissolved Iron and Manganese are oxidized to insoluble precipitates by contact with Greensand Filter CGFE948 Chemical Tank the greensand media, and simultaneously filtered out. Hydrogen Sulphide is reduced to an insoluble sulphur precipitate, which is also filtered in the bed. Water coming out of the greensand filter is virtually free of Iron, Manganese and Hydrogen Sulphide. When the oxidizing capacity of the greensand bed is exhausted, the system automatically backwashes to rid it of the trapped Iron, Manganese & Hydrogen Sulphide and regenerates using Potassium Permanganate which is stored in a separate small container. CAUTIONS BEFORE INSTALLATION Follow all plumbing codes for installation. To operate properly, the well pump flow rate must exceed the backwash flow rate (5 US GPM (19 LPM)). If your well pump does not deliver this flow rate, do not install the unit as it will not work properly. You may need to either change the well pump or call Rainfresh for a custom size unit that will operate within your pump specifications. The automatic control valve works on 110V AC. We recommend a GFI (ground fault interrupter) 120 volt outlet within 5 feet of the filter. Extension cords are not recommended. If water pipes are used to ground electrical system, you will need to install a jumper wire (#4 gauge solid copper wire) across the filter unit. CGFE systems do not kill or remove bacteria or any other pathogenic microorganisms. To continuously disinfect all the water in your house, we recommend that you install a Rainfresh UV system. Call Rainfresh for details. Protect your unit from freezing - drain the unit if freezing temperatures exist. NOTE: If solder type fittings are used DO NOT USE torch near inlet/outlet connections. All solder joints should be made before joining pipe to filter head. DO NOT over-tighten metal fittings on to unit connections. The unit should only be moved by 2 or more people due to heavy weight. Failure to do so can result in back or other injury. 2
3 INSTALLATION Grounding jumper wire Optional Bypass outside taps Cold water to house Optional Rainfresh sediment filter & UV Disinfection System Hot water to house Pressure Tank Drain Optional Rainfresh Water Softener Well Pump Rainfresh CGFE Filter Water Heater Figure 1. Piping Schematic a) Unpacking the unit The Rainfresh CGFE filter system includes: 1) The main media tank with automatic electronic control valve 2) 110V AC power adapter for control valve 3) Chemical tank (for storing potassium permanganate) & connecting tubing (3/8 ) 4) By-pass valve & Allen key with 2 metal clips and 2 screws 5) Two ¾ Male NPT elbow inlet/outlet fittings 6) Drain Fitting (for 1/2 Hose Hose not included) Unpack the unit and place it at the location where you intend to install the unit. Stand back and look at the main media tank and make sure it is standing straight up and not tilted to one side. Sometimes during shipment, the bottom of the tank will get knocked out of alignment and you will need to straighten it out before starting installation. If your tank is a bit tilted, simply pick the tank up 2 3 inches off the floor and drop it gently but firmly down, favoring the side that needs to be adjusted to make the filter stand straight up again. Make sure your chosen location is fairly level, dry, and protected from possible freezing conditions. The plastic base of the filter is slightly adjustable to non-even floors. If shimming is needed, you can make shims from small, flattened pieces of copper pipe, or some other non-corrosive material but do not use wood. The filter can sit directly on the floor, it will not corrode. DO NOT set the tanks onto make shift platforms as this may cause the filter to topple. The following materials can be used for installing your new system, but it is recommended that you check your local plumbing codes. Copper and PVC, CPVC, and PEX are the most popular. You may choose not to treat the water spigots that go outside used for irrigation or sprinkler systems. You will have to plan the job so that you cut in to feed the CGFE filter AFTER these spigots. Installing the CGFE filter after the pressure tank on a well water system is the preferred location. If you intend to install a water softener for soft water or a UV system for disinfecting the water, these should be installed after the CGFE filter (see Fig 1) 3
4 b) Plumbing in your CGFE Greensand Filter Turn the power off to the well pump then shut off the main water shut off valve which should be located after the pressure tank. If your hot water tank is electric, turn off the power to it to avoid damage to the element in the tank. Open a faucet closest to the pressure tank, but after the main shut-off valve to de-pressurize the lines. Position the filter in the desired location, which is after the pressure tank. Attach the bypass valve to the control valve by pushing it in and secure it with the metal clips and screws (Fig 2). Fully push the inlet/outlet elbow fittings into the open end of the bypass valve and lock them in by inserting the red locking clips into the slots (Fig 3) For ease of installation, orient the inlet/outlet fittings in the direction of the inlet & outlet pipes by simply rotating them (Fig 4) Plumb in the inlet and outlet of the CGFE filter. Plumb in a ½ flexible plastic drain line running from the filter (white elbow hose fitting) (Fig 5). Fig 2 Fig 3 o This can be ran up overhead or down along the floor. If running drain line more than 30 feet overhead, increasing the line size to 3/4" will be required. Please follow your local health dept. Codes for where to run filter discharge water. NEVER MAKE A DIRECT CONNECTION INTO A WASTE WATER DRAIN. A PHYSICAL AIR GAP OF AT LEAST 3" SHOULD BE USED TO AVOID BACTERIA AND WASTEWATER TRAVELLING BACK THROUGH THE DRAIN LINE INTO THE GREENSAND FILTER (Fig 5A). o There will be a fair amount of pressure on this flexible plastic drain line when the filter is in the regeneration mode, so secure it to the drain fitting by a hose clamp. Also secure the drain tube to the wall or ceiling. Bypass valve Closed. Close both inlet & outlet valve Drain Fig 5 Fig 4 Fig 5A Remove the locking clip on the brine fitting & insert one end of the 3/8" tubing (included) into this fitting all the way until the tube can go in no further. Replace the locking clip (Fig 6). Remove the top lid of the chemical tank. The other end of the tubing goes through the small hole near the top of the chemical tank (Fig 7). Bring the end of the 3/8" tubing into the brine well and make the connection with the compression fitting on the safety float. The barbed elbow near the middle of the chemical tank (Fig 8) is for a "gravity" overflow line in case of a malfunction resulting in a tank overflow. This must be run to drain. It uses the same size tubing as the drain line. DO NOT TEE THESE TWO TOGETHER. Fig 6 Fig 7 Fig 8 4
5 With a bucket or hose, pour approximately 1 gallon of water into the chemical tank. The exact level is not critical, but be careful not to overflow the tank. Pour the entire 5 lb jug of potassium permanganate (POT PERM for short) into the chemical tank. Typically, five pounds of potassium permanganate should last three to four months or more before refilling with new potassium permanganate powder is required. Turn on the switch for the well pump. If you had emptied the pressure tank, allow it to fill up until the well pump shuts off. Insert the Allen key into the inlet side of the bypass valve (Fig 9) and turn it on only slightly and watch for leaks. Make sure a faucet is on somewhere and that any aerator is removed Fig 9 to avoid clogging from loosened scale in the pipes. Leave the bypass valve in the same position and slowly turn the main shutoff valve on all the way. If you have no leaks, proceed to the next steps. Connect the control valve to the AC power source. Manually put the CGFE filter into the regeneration cycle by pressing the regeneration button. Turn the bypass valve slightly more into the service position to allow water to run into the unit. You want water to initially fill the tank slowly. Once the tank is full of water, you can open valve fully. This prevents filter media from being pushed up into the control head by the initial surge of water going in. Once the tank is full of water you should start to see water flowing from the drain line. It may look somewhat discoloured at first. This is normal. Once the water runs clear and free from air pockets, turn the bypass valve further and further into the "service position". You should have a full flow to the drain at this point. Your water may be discoloured for a day to two after initial installation or may have small air bubbles. This is normal. Also, it will take a few days to get all the untreated water out of your hot water tank and you may choose to empty your hot water tank at the time of installation and clean it before letting water in from the filter. The system is now ready for use. Check the chemical level in the chemical tank about once a month and top up if required. STARTUP & PROGRAMMING The control valve is pre-programmed at factory. You can however change the default settings or to change regeneration frequency. We recommend setting backwash at least every 3 days with a minimum 10 minute backwash, 60 minute brine draw, 10 minute rinse & 10 minute refill time. If you have questions about programming, please call Rainfresh at When power is first supplied, the valve electronics may take up to two minutes to initialize. During this time the screen will show INTIALIZING WAIT PLEASE. Do not touch any buttons at this time. When the valve reaches the service position, it will display the following information in sequence: Fig 8 1. Date & Time 2. Regeneration Days/Capacity 3. Remaining Days 4. Regeneration Time The control valve has a display screen and 4 buttons 5. Last Regeneration Date 6. Current Flow Rate (GPM) 7. Peak Flow Rate (GPM) 1 3 & 4 2 5
6 1) MENU BUTTON : The function of this key is to enter the level one programming mode where the valve settings can be adjusted. 2) SET / REGEN BUTTON : This button has two functions. The first is to initiate a manual regeneration by holding the button for 3 or more seconds. The second function is while in programming mode, pressing this key allows the user to change the value of each setting. 3 & 4) UP / DOWN : These buttons are used to increase or decrease the value of the settings while in the programming mode. VALVE PROGRAMMING The valve has 2 levels of programming Level 1 and Level 2 You will need to only go through Level 1 programming to start up your unit. Level 2 programming is factory set and can be changed only if desired. Level 1 programming allows you to set - Current time, Current date, Vacation mode LEVEL 1 USER PROGRAMMING STEP 1 : Setting Current Time Press MENU for 3 seconds to unlock screen. Press MENU again and the hour value becomes highlighted once again and the highlighted value flashes. Now press or UP OR DOWN arrows to change the hour values. again to accept the hour value and advance to change the minute value Press SET / REGEN again to accept the AM/PM value. Highlight stops flashing. Continue to Step 2 Press or UP OR DOWN to change the AM/PM value again to accept the minute values and advance to adjust the AM/PM values Press or UP OR DOWN arrows to change the minute value STEP 2 : Setting Current Date & Exit Level 1 Programming From Step 1 Press DOWN arrow to advance to CURRENT DATE once and the MONTH value flashes Now press or arrows to change the month to current month again to accept the month and advance to change the DATE Press SET / REGEN again to accept the YEAR. Highlight moves back to MONTH and stops flashing. Press or to change the YEAR again to accept the DATE and advance to set current YEAR Press or arrows to change the DATE. Press DOWN arrow to advance to VACATION MODE Press DOWN arrow to exit programming mode 6
7 LEVEL 2 USER PROGRAMMING Press and hold UP AND DOWN together for three seconds to enter Level Two Master Programming. The following chart indicates choices and default settings. Note: Default settings are indicated in bold letters NOTE : Use same programming method as you used in level 1 to advance and/or change values. Parameter Option 1 Option 2 Option 3 Option 4 Comments 1 System Language English Spanish French Set to French if desired. Spanish not enabled 2 Valve Operation Softener Filter Iron Leave at default setting Filter 3 Regeneration Mode Meter Delayed Meter Override Calendar Clock Meter Immediate Leave at default setting 4 Regeneration Time 2:00 AM The unit is factory set to backwash at 2:00 AM on the day of backwash. You can change to another time if desired. Capacity Manual Automatic Leave at default setting Calculation 5 Regeneration Days 3 Days Leave at default setting. Before changing this value, contact Rainfresh 6 Backwash 10 Leave at default setting 7 Brine/Rinse 60 Leave at default setting 8 Rapid Rinse 10 Leave at default setting 9 Refill 10 Leave at default setting 10 Restore Default NO Leave at default. Change only if you want to re-start programming from start Manual Regeneration If screen is locked, press MENU for 3 seconds to unlock. To start an immediate backwash, Press the SET/REGEN button for 3 seconds, an option for Delayed or Immediate regeneration will appear. Press the SET/REGEN button again and Delayed will begin flashing. Now press the or buttons and Immediate will flash. Press the SET/REGEN button once and then press the MENU button once. Valve will immediately start manual regeneration. OTHER FEATURES Control Operation during a Power Failure In the event of a power failure, the valve will keep track of the time and day for 48 hours. The programmed settings are stored in a non-volatile memory and will not be lost during a power failure. If power fails while the unit is in regeneration, the valve will finish backwash after power is restored. If the valve misses a scheduled backwash due to a power failure, it will queue backwash at the next backwash time once power is restored. New Sounds You may notice new sounds as your water softener operates. The regeneration cycle lasts approximately 2 hours. During this time, you may hear water running intermittently to the drain. Care of Your Iron Filter To retain the attractive appearance of your new Greensand Filter, clean occasionally with mild soap solution. Do not use abrasive cleaners, ammonia or solvents. Check the chemical level once a month and make sure the level of chemical is decreasing with time 7
8 A) How to calculate Regeneration Frequency : a) Calculate KMnO 4 (Potassium Permanganate) demand Multiply Manganese concentration by 3 and Hydrogen Sulphide (H 2 S) concentration by 5 and add these to the Iron concentration. For example if Iron level is 2 PPM, Manganese is 0.5 PPM and H 2 S is 1 PPM, then KMnO 4 demand = 2 + (3 x 0.5) + (5 x 1) = = 8.5 PPM b) Calculate Unit Capacity Unit capacity in US Gallons is then given by: 37,850 = 37,850 = 1,176.4 US Gal KMnO 4 demand x x c) Estimate water usage in the home Multiply the number of people in the house by 60 to get estimated water consumption per day. For example for 4 people in the house, total water consumed = 4 x 60 = 240 Gal. d) Calculate Regeneration frequency (days between regenerations) Therefore system should be set to regenerate = 1176/240 = 4.9 days = once every 4 days. WINTERIZING THE SYSTEM If the unit is to be winterized, the best way is to close the by-pass valve and unscrew the 2 screws adjacent to the by-pass valves that hold the unit and the by-pass valve together, and carry the unit to a place where it will not be subject to freezing temperatures. TROUBLESHOOTING PROBLEM POTENTIAL CAUSE SOLUTION Filter fails to backwash Filter does not seem to remove iron, manganese or hydrogen sulphide. Loss of water pressure. Drain flows continuously. 1. Electricity interrupted to system 2. Control head malfunction 1. Bypass valve is in the bypass position. 2. System may not be regenerating soon enough 3. Chemical tank is empty 1. Iron/Manganese buildup in filter. 2. Not enough water flow available for backwash. 3. Inlet of control plugged. 1. Internal control leak. 2. Control valve jammed in backwash position. 1. Assure continuous power supply to system. 2. Check control head manual for solution. 1. Move bypass valve to service position. 2. Reduce backwash/regeneration interval. 3. Add Potassium Permanganate to chemical tank 1. Increase backwash/regeneration frequency. 2. Check flow rate of pump and make sure it delivers at least 5 US GPM 3. Remove piston and clean control of foreign material. 1. Replace seals, spacers or pistons. 8
9 PARTS LIST DESCRIPTION 1 CGFE Control Valve complete 2 Inlet/Outlet Fitting - elbow (90 ) ¾ 3 Locking clip for inlet/outlet 4 Locking clip for bypass valve 5 Bypass valve assembly 6 Bypass valve metal clips and screw set 7 Drain fitting (Elbow) 8 Brine elbow fitting 3/8 stem x 3/8 QC 9 AC power adapter 110V AC 10 Chemical Tank 11 Mineral tank 9 x 48 WARRANTY This System is warranted to the original Consumer purchaser for a period of one (1) year, from the date of purchase, against defects in materials or workmanship. The electronic controls and mineral tank are warranted for 5 and 10 years respectively against defects in materials or workmanship. The company's obligation under this warranty shall consist of repair or replacement, at its option, of any part found by company inspection to be defective, provided that the product has not been misused, abuse, altered or damaged by Consumer with respect to the original installation, as determined by the company. This warranty will not apply if feed water does not meet specifications of this system. This limited Warranty applies only to a unit when returned to the Warrantor at the owner s expense and in accordance with shipping instructions received from the Warrantor. This warranty does NOT cover, and is intended to exclude, any liability on the part of Envirogard for any incidental damages, consequential damages, labour charges or any other costs incurred in connection with the purchase, installation, use, maintenance or repair of the system whether under this warranty or any other warranty implied by law. Some provinces/states do not allow the exclusion of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights, which vary from province/state to province/state. This warranty applies only to water filter/systems purchased in Canada or the U.S.A. Jan 2013 Envirogard Products Limited 446 Major Mackenzie Drive East, Richmond Hill, ON L4C 1J2, CANADA Toll Free: Tel: (905) Fax: (905) info@rainfresh.ca Web: 9
TFM Series Water Softener Installation & Operation Manual (Please save for future reference)
TFM Series Water Softener Installation & Operation Manual (Please save for future reference) Thank you for purchasing one of our ENVIROGARD / Rainfresh Water Softeners. We are committed to ensuring that
More informationC Series Water Softener Installation & Operation Manual (Please save for future reference)
C Series Water Softener Installation & Operation Manual (Please save for future reference) Thank you for purchasing one of our ENVIROGARD / Rainfresh Water Softeners. We are committed to ensuring that
More informationC Series Water Softeners Installation & Operation Manual (Please save for future reference)
C Series Water Softeners Installation & Operation Manual (Please save for future reference) Thank you for purchasing one of our ENVIROGARD / Rainfresh Water Softeners. We are committed to ensuring that
More information1850 Series TRIPLE TREAT Operation Manual
1850 Series TRIPLE TREAT Operation Manual BRINE TANK RESIN TANK CARBON TANK System shown with optional tank jackets. Note: 1. Read all instructions carefully before operation. 2. Avoid pinched o-rings
More informationWater Softener & Single Tank Triple Treat System Installation Overview. Using 1850 Metered Valves
Water Softener & Single Tank Triple Treat System Installation Overview Using 1850 Metered Valves System Installation CAUTION: Do not use systems on untreated well water that is microbiologically unsafe.
More informationWS1 Greensand Installation & Start Up Guide
WS1 Greensand Installation & Start Up Guide Thank you for purchasing a WS1 Water System for the removal of iron, manganese and hydrogen sulphide gas. With proper installation and a little routine maintenance
More informationClean Water Made Easy
Clean Water Made Easy http://www.cleanwaterstore.com Pro-OX 1650 Iron Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationNovoSoft 465 Series SIM Water Softener Operation Manual
NovoSoft 465 Series SIM Water Softener Operation Manual Note: 1. Read all instructions carefully before operation. 2. Avoid pinched o-rings during installation by applying (provided with install kit) NSF
More informationWS1 Softener Installation & Start-Up Guide
WS1 Softener Installation & Start-Up Guide Thank you for purchasing a Van Isle Conditioner. With proper installation and a little routine maintenance your system will be providing treated water for many
More informationFleck 2510 SXT Catalox Installation & Start Up Guide
Fleck 2510 SXT Catalox Installation & Start Up Guide For Catalox Filters with PotPerm Bleach Solution Tank Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationModel NFF Iron, Manganese, Hydrogen Sulfide Reduction
Super Filter Model NFF Iron, Manganese, Hydrogen Sulfide Reduction Operating and Maintenance Manual Page 1 of this manual contains operating conditions. 57055 9/07 Enjoy clean, stain-free laundry and dishes...
More information165 Series Iron Filter Valve Manual
165 Series Iron Filter Valve Manual Note: 1. Read all instructions carefully before operation. 2. Avoid pinched o-rings during installation by applying (provided with install kit) NSF certified lubricant
More information5700-E Sediment Filter Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com 5700-E Sediment Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More information7800 Neutralizer Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com 7800 Neutralizer Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your
More informationOwner's Manual. WS Series. Water Softener
Owner's Manual WS-165-150 Series Water Softener Table of Contents WHAT'S INCLUDED 3 OPERATING CONDITIONS 4 ASSEMBLY INSTRUCTIONS 6 FLUSHING THE WATER LINES 13 MASTERPROGRAMMING 14 PROGRAMMING KEYAND GENERAL
More information5900e Greensand Filter Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com 5900e Greensand Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationMetermatic Water Softener. Operation Manual
Metermatic Water Softener Operation Manual Page 5 of this manual contains important maintenance procedures for the continued proper operation of your unit. These MUST be performed regularly for your guarantee
More informationInstallation & Service Manual
Installation & Service Manual Table of Contents Unpacking & Inspection... 2 Basic Guidelines... 2 Specifications... 3 Before Starting Installation Where to install the filter... 4 Tools, pipe, fittings
More informationOWNER S MANUAL. Premium Series Two Tank 1-PLUS-1 Water Conditioner & Whole House Filters
OWNER S MANUAL Premium Series Two Tank 1-PLUS-1 Water Conditioner & Whole House Filters Congratulations! You ve selected our Premium Series Two Tank 1-PLUS-1 water conditioner and whole house filter for
More informationCWS Plus Sediment Filter Installation & Start Up Guide
Clean Water Made Easy www.cleanwaterstore.com CWS Plus Sediment Filter Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationClean Water Made Easy
Clean Water Made Easy http://www.cleanwaterstore.com Pro-OX 5700-E Iron Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine
More informationTITAN VI High Efficiency Water Conditioner Installation and Operation Manual
TITAN VI High Efficiency Water Conditioner Installation and Operation Manual Manufacturer s Warranty Holts Water Conditioning 369 South Mountainway Drive Orem, UT 84058 801-426-9243 To the original purchaser,
More informationInstallation and Operation Manual
Installation and Operation Manual NOTE: RISER / DISTRIBUTOR PIPE SHOULD BE CUT 1/2 BELOW THE TOP SURFACE OF THE TANK INSERT. MTS 95 System REVISION # 3 REVISION DATE SEPTEMBER 12, 2013 2 Table of Contents
More informationUltraviolet (UV) Disinfection System Model RC8
Ultraviolet (UV) Disinfection System Model RC8 INSTALLATION & OPERATION MANUAL (Please save for future reference) System tested and certified by CSA International to NSF/ANSI Standard 55 for disinfection
More informationMP-MBA-45T-1/60T-1 / 75T-1
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MP-MBA-45T-1/60T-1 / 75T-1 with the 268/762 Logix Control Valve July 2006 Table of Contents Page No. Topic Description
More information(UV) - R830F & ) INTRODUCTION
Ultraviolet (UV) Water Disinfection System Model - R830F (Includes Pre-Filter) Installation & Maintenance Instructions (Please save for future reference) INTRODUCTION Rainfresh water disinfection systems
More informationMASTER. Water Conditioning Corp. MP-TS-10T/20T with the 255/762 Logix Control Valve With Vortech. Installation and Operation Manual
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MP-TS-10T/20T with the 255/762 Logix Control Valve With Vortech February 2010 Table of Contents Page No. Topic Description
More informationClean Water Made Easy
Clean Water Made Easy http://www.cleanwaterstore.com Pro-OX 2510 Iron Filter Installation & Start- Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine
More informationTITAN Pro-Max High Efficiency Upflow Water Conditioner Installation and Operation Manual
TITAN Pro-Max High Efficiency Upflow Water Conditioner Installation and Operation Manual TITAN VI Pro-Max Manufacturer s Warranty Holts Water Conditioning 369 South Mountainway Drive Orem, UT 84058 801-426-9243
More informationInstallation, Operation and Maintenance Manual. Infusion Residential Water Softener 169-ISF-1C 169-ISF-2C 169-ISF-3C 169-ISF-4C
Installation, Operation and Maintenance Manual Infusion Residential Water Softener Calcium, magnesium removal system 169-ISF-1C 169-ISF-2C 169-ISF-3C 169-ISF-4C US Water Systems, Inc. 1209 Country Club
More informationOwner's Manual. Whole House Water Softener with Triton Electronic Control Valve. or call
Owner's Manual SoftMAX Whole House Water Softener with Triton Electronic Control Valve ACTIVATE YOUR WARRANTY BY REGISITERING YOUR PRODUCT AT WWW.WATERTECH.COM or call 888-254-8412 Dealer Contact and Product
More informationInstallation and Operation Manual
Installation and Operation Manual 95 BIF / BAF Filter Manual NOTE: 1.5 RISER / DISTRIBUTOR PIPE SHOULD BE CUT 1/2 BELOW THE TOP SURFACE OF THE TANK INSERT. 1. Read all instructions carefully before operation.
More informationFleck 7000 Sediment Filter Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com Fleck 7000 Sediment Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationHOW YOUR UV DISINFECTION WORKS
Ultraviolet (UV) Water Disinfection System Model - R1245 Installation & Maintenance Instructions ( Please save for future reference) INTRODUCTION Rainfresh water disinfection systems utilize the proven
More informationEconoflo SXT Automatic Meter Initiated Water Softener
Econoflo SXT Automatic Meter Initiated Water Softener Operating and Maintenance Manual Page 5 of this manual contains important maintenance procedures for the continued proper operation of your unit. These
More informationGreen Water Systems OWNERS MANUAL. Includes: Installation Procedures, Warranties, Service & Operation Guidelines.
Green Water Systems OWNERS MANUAL Includes: Installation Procedures, Warranties, Service & Operation Guidelines. GS Elite GS PRO GS1 1 Cu. Ft. S. C. S. GS1.5 1 Cu. Ft. S. C. S. GS2 2 Cu. Ft. S. C. S. 7000
More informationFleck 2510 Softener Installation & Start Up Guide
Clean Water Made Easy www.cleanwaterstore.com Fleck 2510 Softener Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More information89 BIF/BAF USER MANUAL
89 BIF/BAF USER MANUAL Owners Manual 1. Read all instructions carefully before operation. 2. Avoid pinched o-rings during installation by applying (provided with install kit) NSF certified lubricant to
More information7500-S Sediment Backwash Filter Guide
Clean Water Made Easy. www.cleanwaterstore.com 7500-S Sediment Backwash Filter Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your system
More informationClean Water Made Easy. Fleck 7000 Tannin Filter Installation & Startup Guide. Questions?
Clean Water Made Easy www.cleanwaterstore.com Fleck 7000 Tannin Filter Installation & Startup Guide For Tannin Filters with Vortech Distributor Screen Thank you for purchasing a Clean Water System! With
More informationHigh Flow 7000 SXT Series Water Softeners
High Flow 7000 SXT Series Water Softeners Operating and Maintenance Manual Read all instructions carefully before operation. #54736 12/08 Performance and Specifications Model Capacity - Grains Flow Rates
More information565 HIM Softener, Iron & Manganese Reduction System
565 HIM Softener, Iron & Manganese Reduction System Owners Manual 1. Read all instructions carefully before operation. 2. Avoid pinched o-rings during installation by applying (provided with install kit)
More informationINSTALLATION AND OPERATING INSTRUCTIONS FOR RW519 RAIN WATER FILTRATION SYSTEM
INSTALLATION AND OPERATING INSTRUCTIONS FOR RW519 RAIN WATER FILTRATION SYSTEM INSTALLATION CAUTIONS Installation must conform to all local and state plumbing codes and regulations. Please read carefully
More informationFleck 5600 Carbon Filter Installation & Start Up Guide
Clean Water Made Easy www.cleanwaterstore.com Fleck 5600 Carbon Filter Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationHigh Flow 7000 SXT Water Softener
High Flow 7000 SXT Water Softener Operating and Maintenance Manual WQA Tested and Certified against CSA B483.1 Read all instructions carefully before operation. #54736WQA 3/11 ii Performance Data Sheet
More information765 IS Greensand Filter. Proud member of Canadian Institute of Plumbing & Heating. Proud member of Canadian Water Quality Association.
765 IS Greensand Filter Proud member of Canadian Institute of Plumbing & Heating. Owners Manual Proud member of Canadian Water Quality Association. 1. Read all instructions carefully before operation.
More information565 TLC Softener & Tannins Reduction System
565 TLC Softener & Tannins Reduction System Owners Manual 1. Read all instructions carefully before operation. 2. Avoid pinched o-rings during installation by applying (provided with install kit) NSF certified
More informationIron Air Charge MangOx 2510 SXT Installation & Start Up Guide
Iron Air Charge MangOx 2510 SXT Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your system will be providing iron
More information6700 Valve Upflow. Automatic Water Softeners Operation Manual. Read all instructions carefully before operation. #57341 Rev.
6700 Valve Upflow Automatic Water Softeners Operation Manual Read all instructions carefully before operation. #57341 Rev. 11/08 US Performance and Specifications Upflow Capacity at Various Salt Dosages
More information6700 Valve Downflow. Automatic Water Softeners Operation Manual. Read all instructions carefully before operation. #51431 Rev.
6700 Valve Downflow Automatic Water Softeners Operation Manual Read all instructions carefully before operation. #51431 Rev. 11/08 US Performance and Specifications Downflow Capacity at Various Salt Dosages
More information7000 Meter Initiated Valve
7000 Meter Initiated Valve Water Softener Operation Manual Read all instructions carefully before operation. #51400 Rev. 2/09 Performance and Specifications Item Model Capacity at regeneration salt levels
More information5900S Softener Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com 5900S Softener Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your
More information565IS Greensand Filter. Proud member of Canadian Institute of Plumbing & Heating. Proud member of Canadian Water Quality Association.
565IS Greensand Filter Proud member of Canadian Institute of Plumbing & Heating. Owners Manual Proud member of Canadian Water Quality Association. 1. Read all instructions carefully before operation. 2.
More informationWater Softener Installation / Operation Manual
Water Softener Installation / Operation Manual BrassMaster and BrassMaster Plus Technical Video Library: http://watercontrolinc.com/residential-technical-support/residential-technical-videos BrassMaster
More information185HE IS Greensand Filter. Proud member of Canadian Institute of Plumbing & Heating. Proud member of Canadian Water Quality Association.
185HE IS Greensand Filter Proud member of Canadian Institute of Plumbing & Heating. Owners Manual Proud member of Canadian Water Quality Association. 1. Read all instructions carefully before operation.
More informationProFlo SXT Valve Downflow / Upflow
ProFlo SXT Valve Downflow / Upflow Automatic Water Softeners Operation Manual Read all instructions carefully before operation. #54719 Rev. 1/09 US Performance and Specifications Downflow Upflow Capacity
More informationWhat to expect from your water softener
What to expect from your water softener All water softeners work on the same basic principal. Hard water flows through a bed of resin and the calcium and magnesium, the minerals that are responsible for
More informationFleck 5600 SXT. Installation Guide. Make a list of all of the plumbing fittings needed to install; a typical list looks like this:
Installation Guide Before you assemble your new system, be sure that the following conditions have been met for placement of your softener: Getting Started Level, firm surface, such as concrete, on which
More informationInstallation, Operation, and Maintenance Manual. Waterlogix Metered Residential Water Softener
Installation, Operation, and Maintenance Manual Waterlogix Metered Residential Water Softener Waterlogix WLS-075 Waterlogix WLS-075C Waterlogix WLS-100 Waterlogix WLS-100C Waterlogix WLS-150 Waterlogix
More informationClean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?
Clean Water Made Easy www.cleanwaterstore.com CWS Time Clock Softener Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationAUTOTROL 363TC AUTOMATIC FILTER VALVE SERVICE MANUAL
AUTOTROL 363TC AUTOMATIC FILTER VALVE SERVICE MANUAL 2013 Pentair Residential Filtration, LLC www.pentairaqua.com/pro TABLE OF CONTENTS MANUAL OVERVIEW... 2 SAFETY INFORMATION... 2 TYPICAL TOOLS AND FITTINGS
More informationClean Water Made Easy
Clean Water Made Easy www.cleanwaterstore.com CWS Plus Neutralizer/Birm Blend Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine
More information5900e Neutralizer Installation & Start Up Guide
Clean Water Made Easy www.cleanwaterstore.com 5900e Neutralizer Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your
More informationMKTF CRO-Series 5-Stage Reverse Osmosis System Installation and Maintenance Manual
MKTF - 215 CRO-Series 5-Stage Reverse Osmosis System Installation and Maintenance Manual Please fill out the following information at the time of installation. Save for future reference. Model: Date Code:
More information6700XTR Valve Downflow
6700XTR Valve Downflow Automatic Water Softeners Operation Manual Read all instructions carefully before operation. #51545 Rev. 11/08 US Performance and Specifications Downflow Capacity at Various Salt
More information5900S Arsenic Filter Operation & Maintenance Manual
Clean Water Made Easy www.cleanwaterstore.com 5900S Arsenic Filter Operation & Maintenance Manual Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationFully Automatic Water Softeners
OWNERS GUIDE TO INSTALLATION AND OPERATION Fully Automatic Water Softeners SINGLE TANK CABINET MODELS TWO TANK MODELS Read the instructions carefully and learn the specific details regarding installation
More informationFully Automatic Water Filters
INSTALLATION INSTRUCTIONS Fully Automatic Water Filters INSTALLATION INFORMATION Model No. Unit Date Code Date Installed WATER ANALYSIS RECORD Hardness GPG Sulfur PPM Iron PPM ph Manganese PPM Tannins
More informationModel 700MM Water Softener
INSTALLATION AND SERVICE MANUAL Model 700MM Water Softener Version 1 4343 S. Hamilton Road, Groveport, Ohio 43125 Table of Contents NOTES... 1 GETTING MAXIMUM EFFICIENCY FROM YOUR APPLIANCE... 2 CHECKLIST
More informationThe Inlet and Outlet should be as per below illustration. This will ensure that water will flow through the filter in an upflow configuration
Owners Manual The Inlet and Outlet should be as per below illustration. This will ensure that water will flow through the filter in an upflow configuration INLET OUTLET NRV Filter FOLLOWTHE INSTALLATION
More informationInstallation Manual & Owner s Guide
Installation Manual & Owner s Guide Table of Contents Benefits of Iron Shield +... 1 How Iron Shield + Works... 2 Unpacking & Inspection... 3 Basic Guidelines... 3 Specifications... 4 Regeneration Schedules...
More informationAUTOTROL 363 DEMAND AUTOMATIC FILTER VALVE Service Manual
AUTOTROL 363 DEMAND AUTOMATIC FILTER VALVE Service Manual 2014 Pentair Residential Filtration, LLC www.pentairaqua.com/pro TABLE OF CONTENTS MANUAL OVERVIEW... 2 SAFETY INFORMATION... 2 TYPICAL TOOLS AND
More information10 Year Limited Warranty
THE PROFESSIONAL LINE OF WATER CONDITIONERS MODELS AMP50, AMP51, AMP55, AMP51IF, AND AMP51NF OWNER S MANUAL AND INSTALLATION GUIDE VERSION 1.0 CANADA 10 Year Limited Warranty To Whom Warranty Is Extended
More information6700XTR Upflow Valve. Water Softener Operation Manual. Read all instructions carefully before operation. #51548 Rev. 2/09
6700XTR Upflow Valve Water Softener Operation Manual Read all instructions carefully before operation. #51548 Rev. 2/09 Performance and Specifications Item Model Capacity at regeneration salt levels Service
More informationINSTALLATION AND SERVICE MANUAL
INSTALLATION AND SERVICE MANUAL W ater Softeners: waterboss fi 550, 700 and 900 Ver. 3.0 waterboss 4343 S. Hamilton Road, Groveport, Ohio 43125 Table of Contents QUESTIONS?... 1 GETTING MAXIMUM EFFICIENCY
More informationInstallation Instructions & Owner's Manual. IM & INT Series
Installation Instructions & Owner's Manual IM & INT Series 12630 US Highway 33 N. Churubusco, IN 46723 Phone: (260) 693-1972 Fax: (260)693-0602 www.sterlingwatertreatment.com TABLE OF CONTENTS: Preinstallation
More informationIMPORTANT SAFETY INFORMATION READ ALL...
INSTALLATION and SERVICE MANUAL HOUSEPURE MODELS HP03 and HP04 736-0137 Table of Contents IMPORTANT SAFETY INFORMATION READ ALL... 3 P/N 41482 Rev A 06/04 INSTRUCTIONS BEFORE USING... 3 FEEDWATER... 4
More informationAutotrol Performa FA Valve
Autotrol Performa FA Valve With 400 Series Control Water Conditioning Control System Dealer Installation, Operation, and Maintenance Manual Table of Contents Installation................................
More information765 Valve Filters (Taste & Odor, Nextsand, Multimedia, Neutralizer)
765 Valve Filters (Taste & Odor, Nextsand, Multimedia, Neutralizer) Owners Manual FOLLOWTHE INSTALLATION INSTRUCTIONS CAREFULLY. FAILURE TO INSTALL THE UNIT PROPERLY VOIDS THE WARRANTY. BEFORE YOU BEGIN
More informationFULLY AUTOMATIC WATER SOFTENER
OWNERS GUIDE TO INSTALLATION AND OPERATION Section: 6.10.130 FM2035 0302 Supersedes 0102 FULLY AUTOMATIC WATER SOFTENER MODEL 340 SAFETY INFORMATION Read the instructions carefully and learn the specific
More informationTier1 Water Home Filtration System
Tier1 Water Home Filtration System Salt-Free Softener OWNERS MANUAL BEFORE YOU BEGIN INSTALLATION, READ THIS ENTIRE MANUAL. FOLLOW THE INSTALLATION INSTRUCTIONS CAREFULLY. 1. Avoid pinched o-rings during
More informationWhole House Filter Model: WH-LD
INSTALLATION, OPERATION AND MAINTENANCE MANUAL Save manual for future reference Whole House Filter Model: WH-LD! WARNING Please read carefully before proceeding with installation. Your failure to follow
More informationispring Whole House Water Filter Systems USER S MANUAL
ispring Whole House Water Filter Systems USER S MANUAL Version 2014-5 Introduction Congratulations on your purchase of the ispring Whole House Water Filter system. Featuring a three-stage filtration process,
More informationPro-Ox 5900S-AIR Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com Pro-Ox 5900S-AIR Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your
More informationOwner s Manual. Models: AWP-SE1 and AWP-SE2 Series Water Conditioners _RevG
Owner s Manual Models: AWP-SE and AWP-SE Series Water Conditioners 5 Clair Rd. W, Guelph, Ontario, Canada NL R t. (+) 59.76.0 tf..800.65.76 (US and Canada only) t. + 7 77 0 (Europe only) f. (+) 59.76.5069
More informationInstallation, Operation and Maintenance Manual
Installation, Operation and Maintenance Manual ScaleStop Residential Systems Chemical Free, Salt Free Scale Prevention NSS-744R NSS-844R NSS-948R NSS-1054R NSS-1252R next filtration technologies inc. P.O.
More informationPro-Ox 5900S Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com Pro-Ox 5900S Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your system
More informationRead all instructions carefully before operation. Rev 0, March 1, 2015 # Series Manual BIF Chem-Free Filter
Read all instructions carefully before operation. Rev 0, March 1, 2015 #54836 465 Series Manual BIF Chem-Free Filter TABLE OF CONTENTS System Specifications... 3 How the System Works... 3 Main Valve functions...
More information5900-BT Softener Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com 5900-BT Softener Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your
More informationDownloaded from manuals search engine
WATER CONDITIONING APPLIANCE 60 SERIES OWNER S MANUAL AND INSTALLATION GUIDE VERSION 5.2 25 Year Limited Warranty TO PLACE THIS EQUIPMENT UNDER WARRANTY, THE WARRANTY REGISTRATION CARD MUST BE COMPLETED
More informationSpectrum TM. Installation, Service & Operation Manual O FLO. SoftH 2. Water Softener. Table of Contents
Installation, Service & Operation Manual SoftH 2 O FLO Water Softener Table of Contents 1. Description & Equipment Adjustments p.2 2. Components, Features & Functions p.3 3. Valve User Interface p.4 4.
More informationOwners Manual Models: 080-MXX-100, 080-MXX-150, 080-MXX-200, 080-MXX-250. US Water Systems Matrixx Commercial Water Softener
Visit us online at www.uswatersystems.com US Water Systems Matrixx Commercial Water Softener Owners Manual Models: 080-MXX-100, 080-MXX-150, 080-MXX-200, 080-MXX-250 REVISION # 1.1 REVISION DATE : November
More informationEvolve Series. Water Softeners and Conditioners. For Models: EV1 EV2 EVR EVRC EVRS EVRCS. For Cabinet Models: EVC EVCS
Evolve Series Water Softeners and Conditioners For Models: EV EV EVR EVRC EVRS EVRCS For Cabinet Models: EVC EVCS TABLE OF CONTENTS Pre-Installation Instructions for Dealers... Bypass Valve.... Installation....5
More informationFully Automatic Water Softeners
OWNERS GUIDE TO INSTALLATION AND OPERATION Fully Automatic Water Softeners FW0782 0211 Supersedes 0410 Models S15DC29DR and S15DC39DR SAFETY INFORMATION Read the instructions carefully and learn the specific
More informationDemand Tannin / Hardness Softener Manual
Demand Tannin / Hardness Softener Manual Installation / Operation Manual Water Softeners Softener Specifications...Page 3 Softener Installation...Page 5 Control Start Up Procedures...Page 10 Error Codes...Page
More informationInstallation and Operation Manual
Model EPWHCW Central Water Filtration System How to install, operate and maintain your Central Water Filtration System If you have any questions or concerns when installing, operating or maintaining your
More informationSanitizer Series. Water Conditioners
Sanitizer Series Water Conditioners TABLE OF CONTENTS Installation Instructions..........................................3-4 Start-up Procedures.............................................5-6 Programming
More informationSYSTEMS for CATALYTIC FILTERS
OP40U5F, OP40B5F, OP80U10F, OP80B10F, OP120U15F & OP120B15F INSTALLATION, OPERATION & SERVICE INSTRUCTIONS Hydrogen Sulfide Removal SYSTEMS for CATALYTIC FILTERS NO DIAPHRAGMS OR AIR CELLS COMPLETELY CORROSION
More informationClean Water Made Easy
Clean Water Made Easy h p://www.cleanwaterstore.com Pro OX 8500 Iron Filter Installa on & Start Up Guide Thank you for purchasing a Clean Water System! With proper installa on and a li le rou ne maintenance
More informationGE & PROFILE SmartWater Softener Systems
GE & PROFILE SmartWater Softener Systems INSTALLATION INSTRUCTIONS GE Models GNSF18Z01, GNSF2Z01, GNSF5Z01, GXSF2Z01 & Profile Model PNSF1Z01 TABLE OF CONTENTS: Page # Important Installation Recommendations
More information