EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

Size: px
Start display at page:

Download "EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons"

Transcription

1 TG1Y (388) EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons Each circuit includes a fully hermetic compressor with a crankcase heater and internal line break motor protection, a co-axial condenser with copper tubing inside a steel casing, a high pressure control, a filter-drier, a compressor lockout circuit, an expansion valve, and a full operating charge of refrigerant-22. Units include a one-year limited warranty on all replacement parts and a five-year limited warranty on each compressor. These units have been tested by Underwriters Laboratories and will be shipped with a UL label. DESCRIPTION These units are completely assembled, piped, wired, charged and tested at the factory and are shipped ready for immediate installation. Only the power supply wiring, the thermostat wiring, the condenser water piping, the condensate drain piping and the ductwork are required to complete the installation. The blower section of the 15-ton unit can be removed to simplify rigging on renovation jobs where the equipment may have to be moved through doorways, elevator shafts and/or stairways. All of these vertical, indoor units include a well-insulated cabinet, a centrifugal blower, a 1750 RPM blower motor, an adjustable V-belt drive, 1" throwaway filters, a 24-volt temperature control circuit, 1" flanges for both the supply and return air duct connections, a copper tube/aluminum fin evaporator coil, and either one (CED060) or two (CED090, 120, 180) refrigerant circuits. APPLICATION FLEXIBILITY These "cooling only" units can be applied with: 1. Cooling towers. 2. Well or surface water providing the temperature and the GPM of the water meet the application limitations of the unit. 3. Brackish or salt water and a secondary heat exchanger. They can be installed: 1. Within the conditioned space as "free standing" units without any ductwork. Supply air plenum and return air grille accessories are available for these freestanding applications. 2. In an equipment room with both supply and return air ductwork. Hydronic coils and electric heaters are available for "cooling/heating" applications.

2 TG1Y ACCESSORIES - Field Installed SUPPLY AIR PLENUMS - These fully insulated plenums are available for free standing units located within the conditioned space, are shipped knocked-down for easy field assembly, are finished to match the exterior of the basic unit, and have double deflection grilles that can be adjusted to vary the throw, spread and drop of the supply air. RETURN AIR GRILLES - These expanded metal grilles are available for free standing units located within the conditioned space, are finished to match the exterior of the basic unit and are shipped in one piece for easy installation. HOT WATER COILS - These drainable coils have 2 rows of 1/2" copper tubes, 8 aluminum fins per inch, a casing that is finished to match the exterior of the basic unit, but no water control valve. The coils can be slid out of their casings for easy field installation. STEAM COILS - These non-freeze coils have 1 row of 1" copper tubes, a 5/8" copper tube inside each 1" tube to distribute the steam evenly across the entire length of the coil, 8 aluminum fins per inch, a casing that is finished to match the exterior of the basic unit, but no steam control valve. The coils can be slid out of their casings for easy field installation and are pitched in their casings to facilitate condensate drainage. ELECTRIC HEATERS - Three-phase heaters are available in several capacities to precisely match the heating requirement of the conditioned space. These heaters are designed for easy field installation over the unit s supply air opening, are fully protected against excessive current and temperature by fuses and two high limit thermostats, and are shipped with a UL label. Units with electric heat will require two power supplies - one for the basic unit and one for the heater. ELECTRIC HEAT KIT - This wiring harness is required to interconnect an electric heat accessory with the basic unit. ANTI-CYCLE TIMERS - These timers provide a 5-minute "OFF CYCLE" whenever a compressor shuts down. They include a low voltage cutout that can be adjusted to prevent a compressor from operating when the voltage of the main power supply drops 10% below its nominal rating. WATER REGULATING VALVES - These valves are available to control the flow of condenser water on installations where the temperature of the water may drop below 60 F. These valves reduce water use and maintain more stable operating conditions. THERMOSTATS - Wall-mounted thermostats and subbases (24-volt) with system and fan switches are available to control the operation of "cooling only" units or units with a heating accessory. APPLICATION DATA Limitation Minimum Maximum C2ED Supply Air, CFM C2ED C2ED C2ED Air Temperature Entering Wet Bulb Dry Bulb C2ED Condenser Water, GPM C2ED C2ED C2ED Condenser Water-Side Working Pressure, PSIG Leaving Condenser Water Temperature 3, F Steam Pressure, PSIG - Steam Coils Entering Air Temperature, F Leaving Air Temperature, F 150 Accessories Steam Pressure, PSIG - 0 Hot Water Coils Entering Air Temperature, F 40 - Leaving Air Temperature, F 150 Electric Heat Steam Pressure, PSIG - 77 The water-cooled condensers in these units have copper tubing and are NOT suitable for salt or brackish water. Do not install these units outdoors nor in any area where the surrounding temperature may drop below 32 F. 1 The water pressure must be great enough to overcome the pressure drop of the condenser and the condenser water piping. 2 Although the water side is only leak tested for 150 psig, the maximum water-side working pressure of the condenser is 450 psig. Class 150 fittings in the unit s condenser water piping are good for 300 psig. For 300 psig applications, a sealing material ( Locktite or equivalent) must be applied to all threaded connections to assure a leak-tight installation. The water regulating valve accessories are limited to a maximum 150 psig. 3 The limitations for entering condenser water temperature will vary with condenser water GPM. 4 A minimum steam pressure of 5 psig is required if the entering air temperature should drop below 45 F. 2 Unitary Products Group

3 AIR RATINGS TG1Y COOLING CAPACITY 1 POWER NET CAPACITY POWER INPUT, EFFICIENCY, MODEL SUPPLY MBH KW EER C2ED060A C2ED090A C2ED120A Ratings are in accordance with ARI Standard 210. Ratings are limited to equipment rated below 135 MBH. 2 These EER s include an allowance (10 watts per MBH of cooling capacity) for the cooling tower fan motor and circulating pump. Model Air On Evaporator Coil Total Leaving Condenser Water Temperature F Condenser Temp. F CFM Water Water Total Sens. Total Sens. Water Water Total Sens. Total Sens. DB WB GPM KW2Range MBH MBH MBH MBH KW2 Range KW2 Range KW2 Range MBH MBH MBH MBH F F F F ED060 (1 Phase) ED060 (3 Phase) ED ED ED Nominal Rating 1 These capacities are gross ratings. For net capacities, determine the KW requirement of the supply air blower motor per the published BLOWER PERFORMANCE data. Convert KW to MBH per the following equation and deduct this equivalent heat from the gross cooling ratings. Blower Motor KW x MBH = Blower Motor Heat (MBH) KW 2 Compressor KW only. For total unit KW, add the KW requirement of the supply air blower motor per the BLOWER PERFORMANCE data. Unitary Products Group 3

4 TG1Y CORRECTION FACTORS - All Models Rating % CFM % GPM Total Capacity Sensible Capacity Compressor KW NOTE: Adding 40% by weight ethylene blycol to the condenser water for year-round opeation will: decrease the unit capacity by 5%. increase the unit power requirement by 8%. increase the condenser water pressure drop by 12%. CONDENSER WATER PRESSURE DROP Model ED060 ED090 Condenser Water Pressure Drop, Condenser Water Pressure Drop, Model GPM PSI GPM PSI ED ED SUPPLY AIR BLOWER PERFORMANCE 1 RPM SP 2 BHP 3 CFM KW SP 2 BHP3 KW SP 2 BHP 3 KW SP 2 BHP 3 KW SP 2 BHP 3 KW ED ED ED ED NOTE: Refer to Form AD1 for blower performance curves. RPM range for th standard, factory-mounted drive components. Exceeds the BHP limitation of the standard factory mounted blower motor. Note the ED060A46 has a 1 HP blowermotor that can operate at 1.15 BHP providing the unit is not equipped with ahot water or steam coil. 1 Unit resistance is based on a wet evaporator coil and clean filters. 2 Available static pressure i IWG to overcome the resistance of the duct system and any accessories added to the unit. Refer to the respective tables for the resistance of these accessories and for additional motor and drive data. 3 Motors can be selected to operate into their service factor because they are located in the moving air stream, upstream of any heating device. Units with steam or hot water coils are the only exception. On these units, the BHP must not exceed the nominal HP rating of the motor. 4 Unitary Products Group

5 STATIC RESISTANCES FOR UNIT ACCESSORIES (IWG) Unit Model ED060 ED090 ED120 ED TG1Y Accessory CFM KW Electric Heaters 16 KW KW Supply Air Plenum Return Air Grille Hot Water Coil Steam Coil KW Electric Heaters 16 KW KW KW Supply Air Plenum Return Air Grille Hot Water Coil Steam Coil KW Electric Heaters 16 KW KW KW Supply Air Plenum Return Air Grille Hot Water Coil Steam Coil KW KW Electric Heaters 26 KW KW KW Supply Air Plenum Return Air Grille Hot Water Coil Steam Coil BLOWER MOTOR AND DRIVE DATA MODELS HP MOTOR POWER SUPPLY BLOWER (RPM) ADJUSTABLE MOTOR PULLEY PITCH BORE DIA. (IN.) (IN.) FIXED BLOWER PULLEY PITCH BORE DIA. (IN.) (IN.) DESIG- NATION BELTS PITCH LENGTH (IN.) 06 3/4 208/ /8 ED /4 A /8 ED / / / A ED / / A ED / / A *All of these motors are 1750 RPM and have a 56 frame, inherent protection and permanently lubricated ball bearings. The 3/4 HP motor is split phase and has a resilient base and a 1. service factor. All of the 3-phase motors have a solid base and a 1.15 service factor. CAUTION: Do NOT operate a motor above its nominal HP rating when a unit is equipped with either a hot water or steam coil accessory. Unitary Products Group 5

6 TG1Y SUPPLY AIR PLENUM PERFORMANCE DATA Angle of Deflection Model ED CFM Face Velocity (FPM) Sound Power DB (10) -12 Watts 0 Throw (Feet) 3 Vertical Louvers 1 (Plan View) Spread (Feet) 3 Horizontal Louvers 2 (Elevation View) 0 18 Vertical Louvers /2 (Plan View) Throw (Feet) 3 Spread (Feet) 3 Horizontal Louvers 2 (Elevation View) 45 Throw (Feet) 3 Vertical Louvers 1 (Plan View) Spread (Feet) 3 Horizontal Louvers 2 (Elevation View) Min. Max. Min. Max. Drop (Feet) 4 Min. Max. Min. Max. Drop (Feet) 4 Min. Max. Min. Max. Drop (Feet) Adjusting the vertical louvers will vary the throw, the spread and the drop. 2 Adjusting the horizontal louvers will only vary the drop. 3 The velocity of the air will be 1 ft./min. at the minimum distance and 80 ft./min. at the maximum distance. 4 The velocity of the conditioned air at the bottom of the drop will be 50 ft./min. Drafts will occur if the drop extends into the occupied level of the conditioned space. HEATING CAPACITY - Electric Heat Accessory Unit Model Heater Model UL Test Voltage Nominal Ratings 1 Capacity1 Per Stage 1 Per Stage 2 KW MBH KW MBH KW MBH HT ED060 2HT HT HT ED HT HT HT HT HT ED060 2HT HT HT Capacity ratings do not include the heat generated by the supply air blower motor. 3 For 460 volts, multiply the MBH and KWvalues by (460/480) 2 or For 208 volts, multiply the MBH and KW values by (208/240) 2 or For 230 volts, multiply the MBH and KW values by (230/240) 2 or Unitary Products Group

7 STEAM COIL CAPACITY 1, 2 PSIG TG1Y STEAM COIL DRY BULB TEMPERATURE OF AIR ENTERING COIL, F UNIT MODEL CFM MODEL NF0450 ED ED NF ED NF0452 ED These capacities do no include any blower motor heat. 2 Multiply these capacities by the following factors to correct for higher steam pressures. Steam pressure, psig Capacity correction factor NOTE: Steam rate (lbs./hr.) = 1.0 x MBH CAUTION: Do NOT operate a motor above its nominal HP rating when a unit is equipped with a steam coil accessory. HOT WATER COIL CAPACITY 1, MBH WATER COIL ENTERING WATER TEMP. MINUS ENTERING AIR TEMP., F UNIT MODEL GPM CFM MODEL HW0450 ED ED HW ED HW0452 ED These capacities do no include any blower motor heat. NOTE: Water Temperature Drop, F = 2 x MBH GPM CAUTION: Do NOT operate a motor above its nominal HP rating when a unit is equipped with a hot water coil accessory. PRESSURE DROP VS. GPM CAPACITY CORRECTION VS. GPM 1HW0450 1HW0451 1HW0452 GPM Pressure Drop, PSI GPM Pressure Drop, PSI GPM Pressure Drop, PSI HW0450 1HW0451 1HW0452 GPM Capacity Correction GPM Capacity Correction GPM Capacity Correction Unitary Products Group 7

8 TG1Y ELECTRICAL DATA - Basic Unit Compressor Supply Air Blower Motor Unit Max. Min. Model Ampacity, Fuse Size 1 Max. Wire ED Power Power Factor Power 60 C Wire Qty. RLA LRA HP FLA Amps Amps Size 2 Length 3. ft. Full Load Supply, AWG 208V 208V / / / V 230V V 208V 208/ / / V 230V / V / V ea. ea. 230V / V ea. 41ea / / V V ea. ea. 230V V ea. 45 ea V V V 208/ V V V Dual element, time delay fuses. 2 Based on three, 60 C insulated copper conductors in steel conduit. 3 Based on a 3% voltage drop. ELECTRICAL DATA - Electric Heat 1 Model Nominal KW Use With Power Supply Ampacity Amps Max. Fuse Size 4 Amps Min. Wire Size 5 AWG Max. Wire Length 6 Ft HT HT ED HT HS HS ED090, & HS HS HS ED Units with an electric heat require two power supplies. 2 The single element type. 3 Based on three, 60 C insulated copper conductors in steel conduit 4 Based on a 3% voltage drop. When the heater ampacity exceeds 100 amps, minimum wire sizes are based on 75 C wire in lieu of 60 C. 8 Unitary Products Group

9 PHYSICAL DATA - Units and Accessories COMPRESSOR (Fully Hermetic) EVAPORATOR COIL CENTRIFUGAL BLOWER (Forward Curve) MOTORS 1 FILTERS (Throwaway) CONDENSER (Water-Cooled) OPERATING CHARGE OPERATING Weight, Lbs. HOT WATER COIL NON-FREEZE, STEAM DISTRIBUTING COIL (Tube-Within-A-Tube) ELECTRIC HEAT DESCRIPTION UNIT MODEL ED060 ED090 ED120 ED180 Quantity Per Unit 3-3/4 Ton Ton Ton Rows Deep x Rows Wide 3 x 24 3 x 24 3 x 32 4 x 26 Finned Length - inches Face Area - square feet Tube (Copper) OD - inches 3/8 3/8 3/8 1/2 Fins (Aluminum) per inch Diameter x Width - inches 10 x x x x 18 Nominal HP Rating 3/4 1-1/2 2 3 Quantity Per Unit 16" x " x 1" " x 20" x 1" Face Area - square feet Quantity Per Unit 3-3/4 Ton Ton Refrigerant-22, Lbs. - Oz. System # System # Basic Unit Accessories Supply Air Plenum Return Air Grille Hot Water Coil Steam Coil Electric Heat: 10 KW KW KW KW KW Tubes OD, inches 1/2 (Copper) Rows Deep 2 Fins Per Inch 8 (Aluminum) Face Area, square feet Connections (Supply & Return) 1" NPTE Outer Tube OD, inches 1 (Brass) Rows Deep 1 Fins Per Inch 8 (Aluminum) Face Area - square feet Connection Inlet 1-1/2" NPTE Outlet 1-1/2" NPTE % Nickel 59.2 %Chromium 16.0 Watt Density, watts/sq. in Face Area, square feet Refer to Page 5 for additional blower motor and drive data. 2 The 10-ton system is wired for first stage operation TG1Y Unitary Products Group 9

10 TG1Y UNIT DIMENSIONS - ED060 ACCESSORIES ELECTRIC HEATERS - Add 13" To Unit Height When Used. SUPPLY AIR PLENUM - Add 24-3/8" To Unit Height When Used. HOT WATER AND STEAM COILS - Add 4-1/4" To Unit Depth When Used. All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. UNIT (Less Panel) MINIMUM CLEARANCES Front+ 36" 1 Top 24" 2 Right Side 36" 3 Left Side 12" 4 Rear - 5 Bottom - 6 +Return Air Opening 1 Required to service compressor, condenser, and controls in electrical box. Return Air ductwork should not extend below the bottom flange of the duct opening unless it s more than 36" from the front of the unit. 2 Required for Supply Air duct connection. Overall dimension of unit will vary if an electric heater or supply air plenum accessory is used. 3 Required for removal of cooling coil. Only 30" is required for normal service. 4 Required for access to screws that secure the cooling coil to the unit. 5 Panels on the rear of the unit and on the sides of the condenser section are not removable. 6 AIIow adequate clearance to trap the auxiliary drain line. 10 Unitary Products Group

11 UNIT DIMENSIONS - ED090 & ED TG1Y All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. ACCESSORIES ELECTRIC HEATERS - Add 14-1/4" To Unit Height When Used. SUPPLY AIR PLENUM - Add 27-1/2" To Unit Height When Used. HOT WATER AND STEAM COILS - Add 4-1/4" To Unit Depth When Used. UNIT (Less Panel) MINIMUM CLEARANCES Front+ 36" 1 Top 24" 2 Right Side 52" 3 Left Side 12" 4 Rear - 5 Bottom - 6 +Return Air Opening 1 Required to service compressor, condenser, and controls in electrical box. Return Air ductwork should not extend below the bottom flange of the duct opening unless it s more than 36" from the front of the unit. 2 Required for Supply Air duct connection. Overall dimension of unit will vary if an electric heater or supply air plenum accessory is used. 3 Required for removal of cooling coil. Only 30" is required for normal service. 4 Required for access to screws that secure the cooling coil to the unit. 5 Panels on the rear of the unit and on the sides of the condenser section are not removable. 6 AIIow adequate clearance to trap the auxiliary drain line. Unitary Products Group 11

12 TG1Y UNIT DIMENSIONS - ED180 ACCESSORIES All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. UNIT (Less Panel) MINIMUM CLEARANCES Front+ 36" 1 Top 24" 2 Right Side 52" 3 Left Side 12" 4 Rear - 5 Bottom - 6 +Return Air Opening ELECTRIC HEATERS - Add 14-1/4" To Unit Height When Using 10, 16, 26 or 36 KW Heater. Add 21-3/4" To Unit Height When Using 72 KW Heater. SUPPLY AIR PLENUM - Add 27" To Unit Height When Used. HOT WATER AND STEAM COILS - Add 6" To Unit Depth When Used. 1 Required to service compressor, condenser, and controls in electrical box. Return Air ductwork should not extend below the bottom flange of the duct opening unless it s more than 36" from the front of the unit. 2 Required for Supply Air duct connection. Overall dimension of unit will vary if an electric heater or supply air plenum accessory is used. 3 Required for removal of cooling coil. Only 30" is required for normal service. 4 Required for access to screws that secure the cooling coil to the unit. 5 Panels on the rear of the unit and on the sides of the condenser section are not removable. 6 AIIow adequate clearance to trap the auxiliary drain line. 12 Unitary Products Group

13 ACCESSORY DIMENSIONS TG1Y SUPPLY AIRPLENUM WITH ELECTRIC HEAT - Remove this 2-1/2" knockout from the rear panel of the plenum. Route the power wiring conduit through this opening and connect it to the field-supplied fitting on the electric heat accessory. Connect the power wiring to the fuse block in the heater control box. Install the control wiring per basic unit instruction. DO NOT route any field control wiring through the plenum. WITHOUT ELECTRIC HEAT - Install the pwer and the control wiring basic unit instruction. DO NOT route any wiring through the plenum and DO NOT remove this knockout. Plenum Unit Model Plenum Dimensions (inches) Model ED A B C D E F G H K L 1SP /2 24-3/8 31-3/4 15-3/4 7-5/8 7/8 2-1/8 11-1/4 2 1SP /8 28-1/4 27-1/2 49-7/8 17-7/8 8-3/4 7/8 1-1/8 15-1/4 1-3/4 1SP / /4 19-7/8 6-1/ /2 19-1/2 1-3/4 ELECTRIC HEATER Heater Nom. Unit Heater Dimensions (inches) Model KW Model ED A B C D E F G H K L M 2HT045010, HT045016, /8 22-1/2 13 7/8 4 1/2 5-1/4 1-11/16 1-3/4 20-1/8 16-7/8 2HT045026, HS045010, HS045016, HS045026, HS045036, /4-1/4 14-1/ /2 5-1/2 1-1/2 1-1/2 22-1/4 19-1/4 2HS045072, /8 26-3/8 21-3/4 2-3/8 5-1/4 3/4 6-3/8 2-1/4 2-1/2 22-1/4 19-1/4 Unitary Products Group 13

14 TG1Y ACCESSORY DIMENSIONS Grille Unit Model Grille Dimensions (inches) Model ED A B C D 1RG / /2 1RG /2 14-1/2 1RG / /2 17-5/8 STEAM COIL Grille Unit Model Steam Coil Dimensions (inches) Model ED A B C D E F 1NF0450* / /2 2-5/8 10-5/8 1NF0451* /2 2-5/8 13-5/8 1NF0452** /4 32-1/ /2 17-1/2 *Field-supplied filters should be installed in front of the coil because the coil will be mounted over the return air opening of the unit in front of the unit filters. Refer to the respective Unit Detail for Duct Flange Dimensions on ED060, 090 and 120. **Installs between the unit and its blower section. HOT WATER COIL Grille Unit Model Water Coil Dimensions (inches) Model ED A B C D E F G 1HW0450* / /16 2-3/4 3-3/8 6-1/4 1HW0451* /16 2-3/8 3-3/8 5-7/8 1HW0452** /4 32-1/ /32 3-5/ /326-11/16 *Field-supplied filters should be installed in front of the coil because the coil will be mounted over the return air opening of the unit in front of the unit filters. Refer to the respective Unit Detail for Duct Flange Dimensions on ED060, 090 and 120. **Installs between the unit and its blower section. 14 Unitary Products Group

15 FIELD WIRING TG1Y POWER SUPPLY LINE VOLTAGE POWER SUPPLY WIRE IN ACCORDANCE WITH LOCAL AND NATIONAL ELECTRICAL CODE L1 3 L2 L3 TERMINAL BLOCK 1TB Three-phase units with electric heat require two power supplies. The electric heat power supply and ground wire should be connected directly to the fuse block and ground lug in the electric heat control box. Use copper conductors only. Power wiring, dissconnect switch and fusing by field. Use copper conductors only. Only two conductors are required on the single phase 060 unit. GROUND LUG CONTROL Unitary Products Group 15

16 Unitary Products Group P.O. Box 1592, York, Pennsylvania USA Subject to change without notice. Printed in U.S.A. Copyright by York International Corporation All Rights Reserved. SHU 3M Code: EBY, EGY TG1Y

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED (491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ) (994) SPLIT-SYSTEM EVAPORATOR BLOWER K5EU090 and K4EU120 50 Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX coil

More information

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ) Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper

More information

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS 550.23-TG5Y (893) CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L2EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility.

More information

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS Technical Guide SPLIT-SYSTEM EVAPORATOR BLOWERS 7-1/2 and 10 NOMINAL TONS LA090 & LA120 DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS 036-21096-001 (0101) SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The

More information

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ E3FB090/E1FB120/F3EH090 & 120 7-1/2 & 10 NOMINAL TONS (60 HZ) 7 & 9 NOMINAL TONS (50 HZ) (9.0-9.2 EER) 208/230/460 VOLT ONLY 208/230 VOLT ONLY DESCRIPTION YORK has

More information

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS EA090/FA090 DESCRIPTION YORK has combined the latest concepts in modern technology with time-proven quality standards to design a split-system heat pump to meet

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be

More information

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307 DESCRIPTION Technical Guide CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) This 20 ton evaporator blower is designed with two distinct modules to provide maximum application

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT: GENERAL SPECIFICATIONS OUTDOOR UNIT: TECHNICAL GUIDE COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM MODELS HB 180 & HB 240 MODELS LB 180 & LB 240 15 & 20 NOMINAL TONS 9.7 EER Two independent refrigerant

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM HEAT PUMPS 60 HZ MODELS: EF-10 & FF-10

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM HEAT PUMPS 60 HZ MODELS: EF-10 & FF-10 TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS 60 HZ MODELS: EF-10 & FF-10 DESCRIPTION Unitary Products Group (UPG) has combined the latest concepts in modern technology with time-proven quality standards to

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

VertiCool Aurora Engineering Guide

VertiCool Aurora Engineering Guide Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 canbepositionedinupto12differentpositionsandsuspended

More information

MODELS K2EU060A, K4EU090A, & K3EU120A

MODELS K2EU060A, K4EU090A, & K3EU120A AIR COOLED SPLIT-SYSTEM AIR CONDITIONERS INSTALLATION INSTRUCTION Supersedes: 550.23-N2Y (589) 550.23-N2Y (399) MODELS K2EU060A, K4EU090A, & K3EU120A 035-16672 GENERAL These completely assembled 5, 7-1/2

More information

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS SUNLINE 2000ô MODELS: H5CE090, H3CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 9.0-9.5 EER DESCRIPTION These Sunline 2000ô units are completely

More information

C13-Series Engineering Guide

C13-Series Engineering Guide Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................

More information

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13 Tag Data - Split System Air Conditioning Units (Large) (Qty: 6) Item Tag(s) Qty Description Model Number A1 20 ton vfd 6 6-25 Ton Unitary Split Systems ( SSC2 TTA24004H00-TWE240E404A TTA Air Condensing

More information

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump VertiCool CLASSIC Engineering Guide Effective March 2018 Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump Contents Product Features... 3 UNIT FEATURES... 3 OPTIONS:... 3 Physical Data...

More information

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator

More information

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE SUBMITTAL DATA SHEET SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE JOB NAME: LOCATION: PURCHASER: ORDER NO: ENGINEER: SUBMITTED TO: FOR: REF:

More information

TECHNICAL GUIDE COMMERCIAL SPLIT-SYSTEM HEAT PUMP FOUR PIPE SYSTEM DESCRIPTION E*FB180 & 240 F*EH180 & & 20 NOMINAL TONS INDOOR UNIT

TECHNICAL GUIDE COMMERCIAL SPLIT-SYSTEM HEAT PUMP FOUR PIPE SYSTEM DESCRIPTION E*FB180 & 240 F*EH180 & & 20 NOMINAL TONS INDOOR UNIT 036-21126-002-D-1102 TECHNICAL GUIDE CMMERCIAL SPLIT-SYSTEM HEAT PUMP FUR PIPE SYSTEM E*FB180 & 240 F*EH180 & 240 15 & 20 NMINAL TNS DESCRIPTIN Both the outdoor and indoor units are completely piped and

More information

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons 491 East Princess Street York, PA 17403 877-905-1111 717-843-4311 Fax: 717-854-4462 uca@unitedcoolair.com www.unitedcoolair.com VERTICOOL TECHNICAL DATA MANUAL Vertical Air/Water Cooled 3-25 Tons UNITED

More information

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons 007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

VariCool VAV Engineering Guide

VariCool VAV Engineering Guide Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control

More information

SUNLINE 2000 SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS DESCRIPTION FEATURES

SUNLINE 2000 SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS DESCRIPTION FEATURES 50.TGY (95) SINGLE PACKAGE COOLED CONDITIONERS DCE 0, 0, 00 & DCE 07 0, 0, 00 & 07, AND 5 NOMINAL TONS (0 SEER) AND NOMINAL TONS (9 EER) SHOWN SUNLINE 000 DESCRIPTION YORK Sunline 000 units are convertible

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/ 1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5

More information

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons 0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 20 TONS

COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 20 TONS Product Specifications COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER S, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without modification.

More information

MODELS B1PA024, 030 AND 036

MODELS B1PA024, 030 AND 036 STELLAR 2000 SINGLE PACKAGE HEAT PUMPS INSTALLATION INSTRUCTION Supersedes: 511.26-N1Y (892) 511.26-N1Y (893) MODELS B1PA024, 030 AND 036 035-11622 GENERAL YORK Model B1PA units are factory assembled heat

More information

technical guide Water-Cooled Self-Contained Units

technical guide Water-Cooled Self-Contained Units technical guide Water-Cooled Self-Contained Units C-Series, Vertical Technical Guide: YK145.00-EG3 (710) TABLE OF CONTENTS Water-Cooled Self-Contained Units Introduction...............................................................................

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION SPLIT-SYSTEM EVAPORATOR BLOWER ( COOLED) CONTENTS NOMENCLATURE... 3 GENERAL... 3 NOTES CAUTIONS AND WARININGS... 3 PARTS... 3 INSPECTION... 3 LIMITATIONS... 3 INSTALLATION... 3

More information

COMMERCIAL AIR HANDLER

COMMERCIAL AIR HANDLER COMMERCIAL AIR HANDLER FORM NO. H11-532 Featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant RHGM- 090 & 120 SERIES NOMINAL SIZES 7.5 & 10, TONS [26 & 35 kw] TABLE OF CONTENTS Unit Features...3

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

INSTALLATION MANUAL (AIR COOLED) SPLIT-SYSTEM AIR CONDITIONER MODEL: LA120 NOTES, CAUTIONS AND WARNINGS SAVE THIS MANUAL B-0203

INSTALLATION MANUAL (AIR COOLED) SPLIT-SYSTEM AIR CONDITIONER MODEL: LA120 NOTES, CAUTIONS AND WARNINGS SAVE THIS MANUAL B-0203 INSTALLATION MANUAL (AIR COOLED) SPLIT-SYSTEM AIR CONDITIONER CONTENTS NOMENCLATURE............................. 3 GENERAL.................................... 4 SAFETY CONSIDERATIONS.....................

More information

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled FORM 145.05-EG1 (1004) VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU 10 105 Ton Water-Cooled Table of Contents FORM 145.05-EG1 (0804) Features and Benefits.....................................................

More information

Water-Cooled Self-Contained Units

Water-Cooled Self-Contained Units CATALOG FORM SK145.15-EG1 (1017) Water-Cooled Self-Contained Units C-Series, Vertical Nomenclature WATER-COOLED SELF-CONTAINED UNIT 1, 2 3 4, 5, 6 7 8 9 10 11 12 13 14 15 16 17 CS V 180 B 2 M 1 V A A A

More information

COMMERCIAL AIR HANDLER

COMMERCIAL AIR HANDLER COMMERCIAL AIR HANDLER FORM NO. H11-529 REV. 6 Supersedes Form No. H11-529 Rev. 5 Featuring Industry Standard R-410A Refrigerant RHGL- 090, 120, 180 & 240 SERIES NOMINAL SIZES 7.5, 10, & 20 TONS [26, 35,

More information

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(HE, HG) 036, 048 & YTG-A-0506

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(HE, HG) 036, 048 & YTG-A-0506 TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(HE, HG) 036, 048 & 060 3, 4 & 5 NOMINAL TONS 12.2 THROUGH 13.2 SEER DESCRIPTION YORK Sunline Ultra units are convertible

More information

Split System Heat Pumps

Split System Heat Pumps Split System Heat Pumps Split System Heat Pumps 7 1/2-20 Tons - 60 Hz Air Handlers 5-20 Tons - 60 Hz SSP-PRC001-EN Introduction Split System Heat Pump Units... Designed With Your Needs In Mind. The Trane

More information

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium

More information

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons Product Data OMNIZONE 50BRN,BZN006-024 Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems 5 to 20 Nominal Tons The 50BRN,BZN water-cooled and remote air-cooled indoor, self-contained units

More information

Supersedes: N2W (398) N2Z (1298) MODELS BCCB 090 & 120, MODELS BECB090 & 120 (9 EER) 208/230/460 VOLT MODELS ONLY

Supersedes: N2W (398) N2Z (1298) MODELS BCCB 090 & 120, MODELS BECB090 & 120 (9 EER) 208/230/460 VOLT MODELS ONLY INSTALLATION SINGLE PACKAGE HEAT PUMPS 71/2 & 10 TON INSTRUCTION Supersedes: (398) 511.06N2Z (1298) MODELS BCCB 090 & 120, MODELS BECB090 & 120 (9 EER) 03516199 208/230/460 VOLT MODELS ONLY 208/230/575

More information

CoolSpot Engineering Guide

CoolSpot Engineering Guide Engineering Guide Effective December 2017 Air-Cooled, Water-Cooled, Chilled Water or Magna Cool Precision Cooling Package Contents Contents....................................................... 2 Product

More information

ACCESSORY INSTALLATION INSTRUCTION ELECTRIC HEAT ACCESSORY 10, 16, 26, 36 & 72

ACCESSORY INSTALLATION INSTRUCTION ELECTRIC HEAT ACCESSORY 10, 16, 26, 36 & 72 ACCESSORY INSTALLATION INSTRUCTION ELECTRIC HEAT ACCESSORY, 16, 26, 36 & 72 FOR SPLIT-SYSTEM AIR CONDITIONERS 5, 7-1/2, & 15 TONS SPLIT-SYSTEM HEAT PUMPS 7-1/2 & TONS GENERAL This instruction covers the

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT PGF SERIES 7-1/2 Ton C Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Combination gas heating and electric cooling, self contained for year-round comfort. Systems can be installed

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System Due to continuous product

More information

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh PAS Product Specifications STANDARD EFFICIENCY PACKAGE A/C UNIT - 74 to 26 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll compressor on each circuit. Dual, electrically

More information

SPLIT-SYSTEM EVAPORATOR BLOWER (AIR COOLED) INSTALLATION INSTRUCTION Supersedes: Nothing N4C-0500

SPLIT-SYSTEM EVAPORATOR BLOWER (AIR COOLED) INSTALLATION INSTRUCTION Supersedes: Nothing N4C-0500 SPLIT-SYSTEM EVAPORATOR BLOWER (AIR COOLED) INSTALLATION INSTRUCTION Supersedes: Nothing 550.23-N4C-0500 MODEL L*BC240 035-16603 GENERAL This 20 ton evaporator blower is designed with two distinct modules

More information

50TM COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS 50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh PAE Product Specifications ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT - 278 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll compressor on each circuit. Dual, Electrically

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) LISTED MODELS: 018-060 (3 PH) MODELS: 076 (3 PH) ISO 9001 Certified Quality

More information

SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating

SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through tons, up to 7,800 BTUH Heating The SPXB-HW Series "Suite 0" is a compact, throughthe-wall single package vertical HVAC

More information

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series 1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor

More information

50TM TFF COMBINATION HEATING/COOLING UNITS

50TM TFF COMBINATION HEATING/COOLING UNITS 50T-1SB 50TM007-012 50TFF004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS 536306-UAI-B-1009 Electric Heat Accessory 10, 16, 20, 26, 32, 36 & 52kW For Split-System R-410A Air Handling Units Both Air Conditioners and Heat Pumps 7-1/2, 10,

More information

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 25,240* Design CFM: 800 Seasonal

More information

MODELS B3CH 090 & 120A25, A46 MODELS B4CH090 & 120A58 (9 EER) 208/230/575 VOLT MODELS ONLY 208/230/460 VOLT MODELS ONLY

MODELS B3CH 090 & 120A25, A46 MODELS B4CH090 & 120A58 (9 EER) 208/230/575 VOLT MODELS ONLY 208/230/460 VOLT MODELS ONLY SUNLINE 2000 SINGLE PACKAGE HEAT PUMPS INSTALLATION INSTRUCTION Supersedes: 511.06N2Y (1191) 511.06N2Y (293) MODELS B3CH 090 & 120A25, A46 MODELS B4CH090 & 120A58 (9 EER) 03510256 208/230/460 VOLT MODELS

More information

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT -1SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP S W/OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier

More information

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING SOUND REFRIGERANT ENVIRONMENTALLY PAN5 Product Specifications 15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R--410A refrigerant

More information

SUNLINE 2000 ELECTRIC / ELECTRIC SINGLE PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTION Supersedes: N7Y (993) 530.

SUNLINE 2000 ELECTRIC / ELECTRIC SINGLE PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTION Supersedes: N7Y (993) 530. SUNLINE 00 ELECTRIC / ELECTRIC SINGLE PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTION Supersedes: 530.18N7Y (993) 530.18N7Y (295) MODELS D3CE 036, 048 & 060 ( SEER) MODEL D1CE 072 (9 EER) (STYLE B &

More information

48TM GAS HEATING/ELECTRIC COOLING UNITS

48TM GAS HEATING/ELECTRIC COOLING UNITS 48TM-4SB 48TM004-014 GAS HEATING/ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form

More information

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements ADDENDUM 1 CLIENT: PROJECT: TO: FROM: Guilford County Schools (GCS) Southeast High School Auditorium & Gymnasium HVAC Improvements All Prospective Bidders Derrick Giles, SAMR, PLLC. DATE: 6/6/2018 The

More information

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Technical Development Program COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Introduction System

More information

Product Data FEATURES/BENEFITS. 524J PACKAGED AIR -HANDLING UNITS WITH PURONr REFRIGERANT SIZES 07, 08, 12, 14, 16. Indoor air quality features

Product Data FEATURES/BENEFITS. 524J PACKAGED AIR -HANDLING UNITS WITH PURONr REFRIGERANT SIZES 07, 08, 12, 14, 16. Indoor air quality features PACKAGED AIR -HANDLING S WITH PURONr REFRIGERANT SIZES,,,, --- Product Data C09311 Bryant s versatile packaged air-handling units satisfy design requirements with: S Multi-position design for horizontal

More information

48TF GAS HEATING/ ELECTRIC COOLING UNITS

48TF GAS HEATING/ ELECTRIC COOLING UNITS 48TF-4SB 48TF004-014 GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

PAR5. Product Specifications

PAR5. Product Specifications TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced

More information

High Heat COP. High/Low Stage

High Heat COP. High/Low Stage SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin

More information

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS -3SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING S PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier Corporation

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

GUIDE SPECIFICATIONS AQUARIUS ii

GUIDE SPECIFICATIONS AQUARIUS ii Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Heat Pump, Ground Water

More information

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts GTIP60 ISO GT Series, Inch Pounds 60 Hz GT010070 (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts Rev: 903 Rev 1 Revisions: 31103 Changed HZ dwg to field convertible 5902 changed Unit

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

Models 566D 569C,576B with 524A 6to30Tons

Models 566D 569C,576B with 524A 6to30Tons Bryant Air Conditioning COMMERCIAL AIR-COOLED CONDENSING S WITH 524A AIR-HANDLING S Models 566D 569C,576B with 524A 6to30Tons DESCRIPTION Model 569C condensing units are available in nominal 6- to 10-ton

More information

ELECTRIC HEAT Field installed accessory heaters are available in a wide range of capacities with single point wiring connections. High Temp.

ELECTRIC HEAT Field installed accessory heaters are available in a wide range of capacities with single point wiring connections. High Temp. PHE Product Specifications ASHRAE 90.1 EFFICIENCY PACKAGE HEAT PUMP UNIT - 13 & 15 Ton REFRIGERATION CIRCUIT Single reciprocating semi -hermetic compressor on all 13 ton units. Dual semi -hermetic compressors

More information

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105) TECHNICAL GUIDE VARIALE SPEED AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: N1VS 600-2000 CFM LOWERS 2-5 TON COILS OPTIONAL 1 & 3 φ ELECTRIC HEATERS ISO 9001 Certified Quality Management

More information

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on all models All models utilize round copper tube, aluminum plate

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

Product Data FEATURES/BENEFITS 524J***H 6 TO 20 TON DIRECT EXPANSION PACKAGED HEAT PUMP AIR -HANDLING UNIT. Indoor air quality features 524J-H 07-12

Product Data FEATURES/BENEFITS 524J***H 6 TO 20 TON DIRECT EXPANSION PACKAGED HEAT PUMP AIR -HANDLING UNIT. Indoor air quality features 524J-H 07-12 524J***H 6 TO 20 TON DIRECT EXPANSION PACKAGED HEAT PUMP AIR -HANDLING Product Data the environmentally sound refrigerant Certified to ISO 9001 524J-H 07-12 524J-H 16-25 C10899 Bryant s versatile packaged

More information

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS 48HJ-13SB Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT

More information

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS Cooling Capacity from 115,000 to 670,000 Btu/hr Btu/hr Smartwise Innovations... Towards Green, Quality & Reliability Solutions SERIES INTRODUCTION

More information

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility for timesaving

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility for timesaving Product Data 50AH Horizontal Indoor Single-Package Cooling Units 2 to 5 Nominal Tons Single Package Cooling Units Featuring: compact design flexibility easy maintenance high quality and reliability quiet

More information

Product Data. 40RUA/40RUS 6to15TonDirectExpansion 7.5to15TonChilledWater Packaged Air---Handling Units FEATURES/BENEFITS. Indoor air quality features

Product Data. 40RUA/40RUS 6to15TonDirectExpansion 7.5to15TonChilledWater Packaged Air---Handling Units FEATURES/BENEFITS. Indoor air quality features A/S 6to15TonDirectExpansion 7.5to15TonChilledWater Packaged Air---Handling Units Product Data Carrier s versatile packaged air-handling units satisfy design requirements with: ---, the environmentally

More information

Models PF1A PF1B PACKAGED AIR-HANDLING UNITS. 6to10Tons. Form No. PDS PF1A.72.1 FEATURES/BENEFITS

Models PF1A PF1B PACKAGED AIR-HANDLING UNITS. 6to10Tons. Form No. PDS PF1A.72.1 FEATURES/BENEFITS PACKAGED AIR-HANDLING UNITS Models PF1A PF1B 6to10Tons PF1A072-120 PF1B090 FEATURES/BENEFITS Multi-position design can be installed horizontally or vertically without modification Standard sloped drain

More information

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw] PC SERIES 50 Hertz Self-Contained Packaged Air Conditioners 4 and 5 Ton [14.1 kw to 17.6 kw] Nominal Cooling Capacity: 48,000 to 60,000 BTUH The PC 50 Hz self-contained packaged air conditioners are designed

More information