CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

Size: px
Start display at page:

Download "CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42"

Transcription

1 SELF CONTAINED HORIZONTAL UNITS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER ) HEAT PUMP. WCHBZ COOLING ONLY. WCHZ SERIES: WCHBZ - Heat Pump MODELS: 201, 251, 271, 351, 401, 501 COOLING CAPACITIES from 6,0 kw to 16,5 kw SERIES: WCHZ - Cooling only MODELS: 201, 251, 271, 351, 401, 501, 701, 721, 751 COOLING CAPACITIES from 6,4 kw to 25,1 kw

2 CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

3 WATER TO AIR HEAT PUMPS TUBE IN TUBE COAXIAL HEAT EXCHANGER WCHBZ SERIES. WATER TO AIR HEAT PUMPS (TUBE IN TUBE COAXIAL HEAT EXCHANGER) SERIES: WCHBZ MODELS: 201, 251, 351, 401, 501 COOLING CAPACITIES OF: 6,0 TO 16,0 kw Ref (En) Rev

4 WATER TO AIR HEAT PUMPS TUBE IN TUBE COAXIAL HEAT EXCHANGER WCHBZ SERIES Ref (En) Rev. 103

5 WATER TO AIR HEAT PUMPS TUBE IN TUBE COAXIAL HEAT EXCHANGER WCHBZ SERIES. CONTENTS Page Description...4 Construction. Dimensions...5, 6 Technical Specifications...7 Cooling capacities...8, 9 Heating capacities Water volumes...11 to 13 Water pressure drop Airflows. Static pressures...14 Accessories...15, Ref (En) Rev

6 WATER TO AIR HEAT PUMPS TUBE IN TUBE COAXIAL HEAT EXCHANGER WCHBZ SERIES. DESCRIPTION General The WCHBZ series are packaged horizontal ductable, water to air heat pumps, with coaxial tube in tube all copper water/ refrigerant exchanger. Suitable to be fitted to an air duct distribution system. Units are delivered totally finished after a complete final run test, ready to be installed (air distribution, duct system, electric supply, control system, water supply, drain). Units are supplied with R407c refrigerant operating charge. Design and lay-out provide great versatility for any installation as well as easy access for future maintenance. Application mostly for shopping malls. Cabinet Made of high quality galvanized steel plate, finished with electrostatically applied and oven-polymerized polyester powder for optimum resistance against corrosion. The assembly is internally lined with thermo-acoustic insulation. Refrigerant Circuit Made of high grade refrigerant copper tubing, clean and dehydrated. Schrader Valves on high and low sides. Filter drier suction accumulator, reversing valve, etc. Brazing is made with silver alloy under inert atmosphere. Compressors Hermetic, reciprocating. Compressors incorporate internal inherent protection, oil charge and crankcase heater. All compressors are mounted on the unit base on vibration eliminators. Indoor coil Made of aluminium fins and 3/8 seamless copper tubing, mechanically expanded. Water / refrigerant heat exchanger Tube in tube type (co-axial), all copper, counterflow, water refrigerant heat exchanger. Fans Centrifugal fan that allows for air distribution duct system. Up to model 401 are direct drive motor ( ). Model 501 incorporates a 230/400V.3.50 motor. Transmission is made through pulleys and belt for airflow, static pressure regulation. Fans are of reduced sound level, incorporated pre-lubricated bearings and are statically and dynamically balanced. Expansion Device Calibrated capillaries up to model 401. Restrictor (calibrated piston) on model 501. Air filter Made of polyurethane foam, washable. Fire class M1. Operation and control - Room thermostat. - Contactors for compressor and fan motor. - Overloads for three-phase fan motor. - High pressure switch (manual reset) and low pressure switch (automatic reset). - Terminal block for supply and controller Options - Electric heaters - Water regulating valve - Compressor jacket - Etc. Electric Supply Models 201 and 251: 230V 1Ph and 400V 3Ph 50Hz Models 351, 401 and 501: 400V. 3Ph. +N, 50Hz Some models available at 230V 3Ph 50 (to be consulted) OPERATION LIMITS COOLING Water inlet Indoor Air temperature Dry Bulb Wet Bulb Standard 30 C 27 C 19 C Minimum 15 C 21 C 15 C Maximum 40 C 32 C 23 C HEATING Water inlet Indoor Air temperature Dry Bulb Wet Bulb Standard 16 C 20 C Minimum 10 C 20 C Maximum 24 C 26 C Ref (En) Rev. 103

7 WATER TO AIR HEAT PUMPS TUBE IN TUBE COAXIAL HEAT EXCHANGER WCHBZ SERIES. DIMENSIONS. CONSTRUCTION MOD. 201, 251, 351, 401 J L F G Detail A I K C D E H A B Detail A Water outlet Water inlet Water inlet M N O P Q R S CONSTRUCTION DETAILS 1. Electric panel 2. 3/4" Drainage (male) 3. Air filter 4. Fan motor 5. Fan 6. Electric heater (optional) 7. Indoor coil 8. Water refrigerant heat exchanger 9. Compressor 10. Power supply 11. Water outlet 12. Water inlet 6 DIMENSIONS (mm) MODEL A B C D E F G H I J K L M N O P Q R S , WATER CONNECTIONS MODEL Size (male) 1/2" 1/2" 1/2" 3/4" APPROXIMATE WEIGHT (kg) MODEL Net weight Packed weight Ref (En) Rev

8 WATER TO AIR HEAT PUMPS TUBE IN TUBE COAXIAL HEAT EXCHANGER WCHBZ SERIES. DIMENSIONS. CONSTRUCTION MOD. 501 Detail A Detail A Water outlet Water outlet Water inlet WATER CONNECTIONS MODEL 501 Size (male) 3/4" APPROXIMATE WEIGHT (kg) MODEL 501 Net weight 166 Packed weight 186 CONSTRUCTION DETAILS 1. Water refrigerant heat exchanger 2. Electric panel 3. Indoor coil 4. Electric heater (option) 5. Fan 6. Fan motor 7. Compressor 8. 3/4" drainage (male) 9. Air filter 10. 3/4 drainage (male) 11. Water outlet (male) 12. Water inlet (male) 13. Power supply Ref (En) Rev. 103

9 WATER TO AIR HEAT PUMPS TUBE IN TUBE COAXIAL HEAT EXCHANGER WCHBZ SERIES. TECHNICAL SPECIFICATIONS MODEL WCHBZ Cooling capacity kw 6,0 8,1 11,1 13,0 16,5 Heating capacity kw 6,9 9,1 12,6 16,0 19,6 COMPRESSOR Type Reciprocating Voltage (50Hz~) V 230.I 230.I 400.III 230.I 230.III 400.III 230.III 400.III 230.III 400.III Input power (Cooling) kw 1,62 2,12 2,73 3,48 4,24 Input current (Cooling) A 8,3 10,8 3,6 13,9 8,1 4,6 10,3 5,9 12,5 7,2 Input power (Heating) kw 1,37 1,73 2,32 3,08 4,04 Input current (Heating) A 7,0 8,8 2,9 11,9 6,9 3,9 9,1 5,2 11,9 6,9 INDOOR COIL Type Copper tubing coil and aluminium fins Front face area m 3 0,188 0,252 0,252 0,252 0,350 Fin spacing - tube Ø mm - (") 2,1 3/8 2,1 3/8 2,1 3/8 2,1 3/8 2,1 3/8 WATER-REFRIGERANT HEAT EXCHANGER Type Tube in tube, co-axial, all copper Water connections (") 1/2 1/2 1/2 3/4 3/4 INDOOR FAN Type Centrifugal Model 9/7 DD 9/9 DD 9/9 DD 10/10 DD 10/10 SS Motor power kw 0,125 0,125 0,250 0,250 0,550 Voltage (50Hz~) V 230.I 230.III 400.III Input current A 1,2 1,2 2,3 2,3 2,8 1,7 REFRIGERANT R407C - operating charge kg 1,30 1,50 1,60 1,70 2,75 GENERAL SPECIFICATIONS FOR ELECTRIC INSTALLATION Voltage (50Hz~) V 230.I 230.I 400.III 230.I 230.III 400.III 230.III 400.III 230.III 400.III Total input power (Cooling) (1) kw 1,90 2,60 3,50 4,25 5,10 Total Input current (Cooling) (1) A 9,7 13,3 4,4 17,9 10,3 6,0 12,6 7,2 15,1 8,7 Max. Input power (Cooling) (2) kw 2,27 3,11 4,19 5,08 6,10 Max. Input current (Cooling) (2) A 11,6 15,9 5,3 21,4 12,4 7,1 15,0 8,6 18,0 10,4 Total Input power (Heating) (3) kw 18,0 2,50 3,30 4,15 4,95 Total Input current (Heating) (3) A 19,2 12,8 4,3 16,9 9,8 5,6 12,3 7,1 14,6 8,4 Max. Input Power (Heating) (4) kw 2,02 2,81 3,70 4,66 5,55 Max Input current (Heating) (4) A 10,3 14,4 4,8 18,9 10,9 6,3 13,8 7,9 16,4 9,4 Starting current A SOUND PRESSURE LEVEL (at 2 meters) Unit db (A) (1) COOLING (Standard): condensing temperature 40ºC; 27ºC/19ºC DB/WB indoor air. (2) COOLING (Maximum): Condensing temperature 50ºC; 31ºC/21ºC DB/ WB indoor air. (3) HEATING (Standard): Entering water temperature 16ºC; indoor air temperature 21ºC. (4) HEATING (Maximum): Entering water temperature to condenser 24ºC; indoor air temperature 26ºC Ref (En) Rev

10 WATER TO AIR HEAT PUMPS TUBE IN TUBE COAXIAL HEAT EXCHANGER WCHBZ SERIES. COOLING CAPACITIES Model WCHBZ201 WCHBZ251 WCHBZ351 Evap. Airflow l/s Condensing temp. C INDOOR AIR. ENTERING WET BULB TEMPerature 15 C Total capacity kw 5,35 5,13 4,89 4,65 7,22 6,93 6,61 6,27 9,90 9,50 9,05 8,60 Power input kw 1,66 1,82 1,99 2,16 2,28 2,49 2,72 2,96 3,06 3,36 3,66 3,98 Sensible 19 C 3,83 3,68 3,54 3,39 5,17 4,97 4,78 4,58 7,09 6,81 6,55 6,27 Capacity E.D.B.T. 21 C 4,40 4,24 4,09 3,95 5,93 5,72 5,53 5,33 8,13 7,84 7,57 7,30 kw 23 C 4,96 4,81 4,66 4,52 6,69 6,49 6,30 6,10 9,17 8,90 8,63 8,36 25 C 5,35 5,13 4,89 4,65 7,22 6,93 6,61 6,27 9,90 9,50 9,05 8,60 INDOOR AIR. ENTERING WET BULB TEMPerature 17 C Total capacity kw 5,79 5,57 5,33 5,08 7,82 7,52 7,20 6,86 10,71 10,31 9,86 9,41 Power input kw 1,70 1,86 2,02 2,20 2,33 2,55 2,77 3,01 3,13 3,43 3,73 4,05 Sensible 21 C 3,83 3,68 3,53 3,38 5,16 4,96 4,76 4,57 7,08 6,80 6,52 6,26 Capacity E.D.B.T. 23 C 4,39 4,24 4,09 3,95 5,93 5,72 5,52 5,33 8,12 7,84 7,57 7,30 kw 25 C 4,95 4,80 4,65 4,51 6,68 6,48 6,28 6,09 9,16 8,88 8,61 8,35 27 C 5,52 5,37 5,22 5,08 7,45 7,25 7,04 6,86 10,21 9,93 9,65 9,40 INDOOR AIR. ENTERING WET BULB TEMPerature 19 C Total capacity kw 6,22 6,00 5,77 5,52 8,40 8,10 7,79 7,45 11,51 11,10 10,67 10,21 Power input kw 1,75 1,90 2,06 2,24 2,40 2,60 2,82 3,06 3,22 3,50 3,80 4,12 Sensible 23 C 3,82 3,67 3,52 3,38 5,16 4,96 4,76 4,57 7,07 6,80 6,52 6,26 Capacity E.D.B.T. 25 C 4,38 4,24 4,09 3,95 5,92 5,72 5,52 5,33 8,11 7,84 7,57 7,30 kw 27 C 4,95 4,80 4,65 4,51 6,68 6,48 6,28 6,09 9,15 8,88 8,60 8,34 29 C 5,52 5,37 5,22 5,08 7,45 7,25 7,05 6,86 10,21 9,93 9,66 9,39 INDOOR AIR. ENTERING WET BULB TEMPerature 21 C Total capacity kw 6,66 6,44 6,21 5,95 8,99 8,69 8,38 8,03 12,32 11,91 11,48 11,00 Power input kw 1,79 1,94 2,10 2,27 2,45 2,65 2,87 3,11 3,30 3,57 3,86 4,19 Sensible 25 C 3,79 3,65 3,50 3,36 5,12 4,92 4,73 4,54 7,02 6,75 6,48 6,22 Capacity E.D.B.T. 27 C 4,38 4,23 4,08 3,94 5,91 5,71 5,51 5,32 8,10 7,82 7,54 7,28 kw 29 C 4,94 4,79 4,64 4,50 6,66 6,47 6,26 6,07 9,13 8,86 8,58 8,32 31 C 5,51 5,36 5,21 5,07 7,44 7,24 7,03 6,84 10,19 9,91 9,64 9,38 NOTES: 1. Capacities are net after deduction of indoor fan motor heat. 2. E.D.B.T. Indoor air. Entering dry bulb temperature. CORRECTION FACTORS % Airflow Total Heat 0,95 0,97 1,03 1,05 Sensible Heat 0,92 0,96 1,04 1,08 Input power 0,96 0,98 1,02 1, Ref (En) Rev. 103

11 WATER TO AIR HEAT PUMPS TUBE IN TUBE COAXIAL HEAT EXCHANGER WCHBZ SERIES. COOLING CAPACITIES Model WCHBZ401 WCHBZ501 Evap. Airflow l/s Condensing temperature C INDOOR AIR. ENTERING WET BULB TEMPerature 15 C Total capacity kw 11,60 11,12 10,60 10,07 14,72 14,11 13,46 12,78 Power input kw 3,72 4,08 4,44 4,83 4,46 4,89 5,33 5,80 Sensible 19 C 8,30 7,98 7,67 7,35 10,54 10,13 9,73 9,32 Capacity E.D.B.T. 21 C 9,52 9,18 8,87 8,55 12,09 11,66 11,26 10,85 kw 23 C 10,74 10,42 10,11 9,80 13,63 13,23 12,83 12,43 25 C 11,60 11,12 10,60 10,07 14,72 14,11 13,46 12,78 INDOOR AIR. ENTERING WET BULB TEMPerature 17 C Total capacity kw 12,54 12,07 11,55 11,02 15,92 15,32 14,66 13,98 Power input kw 3,80 4,16 4,53 4,92 4,56 4,99 5,43 5,90 Sensible 19 C 8,29 7,96 7,64 7,33 10,52 10,11 9,70 9,30 Capacity E.D.B.T. 21 C 9,51 9,19 8,86 8,55 12,07 11,66 11,25 10,86 kw 23 C 10,73 10,40 10,08 9,78 13,62 13,21 12,79 12,41 25 C 11,96 11,63 11,30 11,00 15,18 14,77 14,34 13,97 INDOOR AIR. ENTERING WET BULB TEMPerature 19 C Total capacity kw 13,47 13,00 12,50 11,96 17,10 16,50 15,86 15,18 Power input kw 3,92 4,25 4,62 5,00 4,70 5,10 5,54 6,00 Sensible 19 C 8,28 7,96 7,64 7,33 10,51 10,10 9,69 9,30 Capacity E.D.B.T. 21 C 9,50 9,18 8,86 8,55 12,05 11,66 11,25 10,85 kw 23 C 10,72 10,40 10,08 9,77 13,61 13,20 12,79 12,40 25 C 11,95 11,63 11,31 11,00 15,17 14,77 14,36 13,96 INDOOR AIR. ENTERING WET BULB TEMPerature 21 C Total capacity kw 14,43 13,95 13,45 12,88 18,32 17,71 17,07 16,35 Power input kw 4,01 4,33 4,69 5,08 4,81 5,20 5,63 6,10 Sensible 19 C 8,22 7,90 7,59 7,28 10,43 10,03 9,64 9,24 Capacity E.D.B.T. 21 C 9,48 9,16 8,84 8,53 12,04 11,63 11,22 10,83 kw 23 C 10,69 10,38 10,05 9,75 13,57 13,17 12,76 12,37 25 C 11,93 11,61 11,29 10,98 15,15 14,74 14,33 13,94 NOTES: 1. Capacities are net after deduction of indoor fan motor heat. 2. E.D.B.T. Indoor air. Entering dry bulb temperature. CORRECTION FACTORS % Airflow Total Heat 0,95 0,97 1,03 1,05 Sensible Heat 0,92 0,96 1,04 1,08 Input power 0,96 0,98 1,02 1, Ref (En) Rev

12 WATER TO AIR HEAT PUMPS TUBE IN TUBE COAXIAL HEAT EXCHANGER WCHBZ SERIES. HEATING CAPACITIES Indoor dry bulb ºC Water inlet temperature ºC MOD. WCHBZ 201. INDOOR AIRFLOW 417 l/s. 18 Pot. kw 6,17 6,46 6,75 7,04 7,30 7,49 7,70 7,92 C.O.P. 3,85 3,91 3,97 4,03 4,07 4,11 4,14 4,18 21 Pot. kw 6,00 6,33 6,61 6,90 7,16 7,37 7,59 7,81 C.O.P. 3,64 3,71 3,78 3,83 3,88 3,92 3,95 3,99 24 Pot. kw 5,86 6,17 6,47 6,74 7,01 7,23 7,45 7,68 C.O.P. 3,42 3,49 3,55 3,63 3,68 3,72 3,76 3,80 MOD. WCHBZ 251. INDOOR AIRFLOW 555 l/s. 18 Pot. kw 8,14 8,53 8,90 9,28 9,62 9,88 10,16 10,45 C.O.P. 3,66 3,72 3,77 3,83 3,87 3,90 3,94 3,97 21 Pot. kw 7,92 8,34 8,72 9,10 9,45 9,72 10,01 10,29 C.O.P. 3,46 3,53 3,59 3,64 3,69 3,73 3,75 3,79 24 Pot. kw 7,73 8,14 8,53 8,88 9,24 9,53 9,82 10,13 C.O.P. 3,25 3,32 3,38 3,45 3,49 3,54 3,57 3,61 MOD. WCHBZ 351. INDOOR AIRFLOW 639 l/s. 18 Pot. kw 11,26 11,80 12,33 12,85 13,32 13,68 14,07 14,46 C.O.P. 3,84 3,90 3,96 4,02 4,06 4,10 4,13 4,17 21 Pot. kw 10,96 11,55 12,08 12,60 13,08 13,46 13,86 14,25 C.O.P. 3,63 3,70 3,77 3,82 3,87 3,91 3,94 3,98 24 Pot. kw 10,70 11,27 11,81 12,30 12,79 13,19 13,60 14,03 C.O.P. 3,41 3,48 3,54 3,62 3,67 3,71 3,75 3,79 MOD. WCHBZ 401. INDOOR AIRFLOW 666 l/s. 18 Pot. kw 14,30 14,99 15,65 16,32 16,92 17,37 17,87 18,37 C.O.P. 3,87 3,93 3,99 4,05 4,09 4,13 4,17 4,20 21 Pot. kw 13,92 14,67 15,33 16,00 16,61 17,10 17,60 18,10 C.O.P. 3,66 3,73 3,80 3,85 3,90 3,94 3,97 4,01 24 Pot. kw 13,59 14,31 15,00 15,62 16,25 16,75 17,27 17,82 C.O.P. 3,44 3,51 3,57 3,65 3,70 3,74 3,78 3,82 MOD. WCHBZ 501. INDOOR AIRFLOW 972 l/s. 18 Pot. kw 17,52 18,36 19,18 19,99 20,72 21,27 21,89 22,50 C.O.P. 3,98 4,04 4,11 4,17 4,21 4,25 4,28 4,32 21 Pot. kw 17,05 17,97 18,78 19,60 20,35 20,94 21,56 22,17 C.O.P. 3,77 3,84 3,90 3,96 4,01 4,05 4,08 4,12 24 Pot. kw 16,65 17,53 18,37 19,13 19,90 20,52 21,15 21,83 C.O.P. 3,54 3,61 3,67 3,75 3,80 3,85 3,89 3,93 NOTES: 1. Heat capacities and COP are for standard airflow and motor. For others, please use correction factor. Factors correction % Airflow Capacity 0,95 0,98 1,02 1,04 COP 0,93 0,97 1,03 1, Ref (En) Rev. 103

13 WATER TO AIR HEAT PUMPS TUBE IN TUBE COAXIAL HEAT EXCHANGER WCHBZ SERIES. WATER FLOWS Water inlet temperatura ºC Model Condensing EWBT Cooling LWT WT LWT WT LWT WT LWT WT LWT WT Temp. ºC C Capacity C l/s C l/s C l/s C l/s C l/s 15 5,35 28,19 0,13 28,80 0,19 29,40 0, ,79 29,10 0,13 29,40 0,19 29,70 0, ,22 30,00 0,13 30,00 0,19 30,00 0, ,66 30,90 0,13 30,60 0,19 30,30 0, ,13 32,59 0,09 33,20 0,13 33,80 0,19 34,40 0, ,57 33,81 0,09 34,11 0,13 34,41 0,19 34,70 0, ,00 35,00 0,09 35,00 0,13 35,00 0,19 35,00 0,38 WCHBZ 21 6,44 36,22 0,09 35,91 0,13 35,61 0,19 35,30 0, ,89 36,97 0,07 37,57 0,09 38,18 0,12 38,79 0,19 39,39 0, ,33 38,47 0,07 38,77 0,09 39,08 0,12 39,39 0,19 39,69 0, ,77 40,00 0,07 40,00 0,09 40,00 0,12 40,00 0,19 40,00 0, ,21 41,53 0,07 41,23 0,09 40,92 0,12 40,61 0,19 40,31 0, ,65 41,33 0,06 41,94 0,07 42,55 0,09 43,16 0,12 43,78 0, ,08 43,14 0,06 43,45 0,07 43,76 0,09 44,07 0,12 44,38 0, ,52 45,00 0,06 45,00 0,07 45,00 0,09 45,00 0,12 45,00 0, ,95 46,78 0,06 46,48 0,07 46,19 0,09 45,89 0,12 45,59 0, ,22 28,19 0,17 28,80 0,26 29,40 0, ,82 29,10 0,17 29,40 0,26 29,70 0, ,40 30,00 0,17 30,00 0,26 30,00 0, ,99 30,89 0,17 30,59 0,26 30,30 0, ,93 32,61 0,13 33,21 0,17 33,80 0,26 34,40 0, ,52 33,82 0,13 34,12 0,17 34,41 0,26 34,71 0, ,10 35,00 0,13 35,00 0,17 35,00 0,26 35,00 0,51 WCHBZ 21 8,69 36,20 0,13 35,90 0,17 35,60 0,26 35,30 0, ,61 36,98 0,10 37,59 0,13 38,19 0,17 38,79 0,25 39,40 0, ,20 38,49 0,10 38,79 0,13 39,10 0,17 39,40 0,25 39,70 0, ,79 40,00 0,10 40,00 0,13 40,00 0,17 40,00 0,25 40,00 0, ,38 41,51 0,10 41,21 0,13 40,90 0,17 40,60 0,25 40,30 0, ,27 41,35 0,08 41,96 0,10 42,56 0,13 43,17 0,17 43,78 0, ,86 43,17 0,08 43,48 0,10 43,78 0,13 44,09 0,17 44,39 0, ,45 45,00 0,08 45,00 0,10 45,00 0,13 45,00 0,17 45,00 0, ,03 46,80 0,08 46,50 0,10 46,20 0,13 45,90 0,17 45,60 0,25 NOTES: EWBT: Entering wet bulb temperature ºC LWT: Water outlet temperature WT: Water flow (l/s) Ref (En) Rev

14 WATER TO AIR HEAT PUMPS TUBE IN TUBE COAXIAL HEAT EXCHANGER WCHBZ SERIES. WATER FLOWS Water inlet temperatura ºC Model Condensing EWBT Cooling LWT WT LWT WT LWT WT LWT WT LWT WT Temp. ºC C Capacity C l/s C l/s C l/s C l/s C l/s ,90 28,20 0,23 28,80 0,35 29,40 0, ,71 29,09 0,23 29,40 0,35 29,70 0, ,51 30,00 0,23 30,00 0,35 30,00 0, ,32 30,91 0,23 30,60 0,35 30,30 0, ,50 32,62 0,17 33,21 0,23 33,81 0,35 34,40 0, ,31 33,82 0,17 34,12 0,23 34,41 0,35 34,71 0, ,10 35,00 0,17 35,00 0,23 35,00 0,35 35,00 0,70 WCHBZ 21 11,91 36,21 0,17 35,90 0,23 35,60 0,35 35,30 0, ,05 36,96 0,14 37,57 0,17 38,18 0,23 38,78 0,35 39,39 0, ,86 38,48 0,14 38,78 0,17 39,09 0,23 39,39 0,35 39,70 0, ,67 40,00 0,14 40,00 0,17 40,00 0,23 40,00 0,35 40,00 0, ,48 41,50 0,14 41,20 0,17 40,90 0,23 40,60 0,35 40,30 0, ,60 41,34 0,11 41,95 0,14 42,56 0,17 43,17 0,23 43,78 0, ,41 43,18 0,11 43,48 0,14 43,79 0,17 44,09 0,23 44,39 0, ,21 45,00 0,11 45,00 0,14 45,00 0,17 45,00 0,23 45,00 0, ,00 46,80 0,11 46,50 0,14 46,20 0,17 45,90 0,23 45,60 0, ,60 28,21 0,28 28,81 0,42 29,40 0, ,54 29,09 0,28 29,40 0,42 29,70 0, ,47 30,00 0,28 30,00 0,42 30,00 0, ,43 30,91 0,28 30,60 0,42 30,30 0, ,12 32,62 0,21 33,22 0,27 33,81 0,41 34,41 0, ,07 33,82 0,21 34,11 0,27 34,41 0,41 34,70 0, ,00 35,00 0,21 35,00 0,27 35,00 0,41 35,00 0,82 WCHBZ 21 13,95 36,19 0,21 35,90 0,27 35,60 0,41 35,30 0, ,60 36,96 0,16 37,57 0,20 38,18 0,27 38,79 0,41 39,39 0, ,55 38,48 0,16 38,79 0,20 39,09 0,27 39,39 0,41 39,70 0, ,50 40,00 0,16 40,00 0,20 40,00 0,27 40,00 0,41 40,00 0, ,45 41,49 0,16 41,19 0,20 40,89 0,27 40,60 0,41 40,30 0, ,07 41,36 0,14 41,96 0,16 42,57 0,20 43,18 0,27 43,79 0, ,02 43,20 0,14 43,50 0,16 43,80 0,20 44,10 0,27 44,40 0, ,96 45,00 0,14 45,00 0,16 45,00 0,20 45,00 0,27 45,00 0, ,88 46,77 0,14 46,47 0,16 46,18 0,20 45,88 0,27 45,59 0,41 NOTES: EWBT: Entering wet bulb temperature ºC LWT: Water outlet temperature WT: Water flow (l/s) Ref (En) Rev. 103

15 WATER TO AIR HEAT PUMPS TUBE IN TUBE COAXIAL HEAT EXCHANGER WCHBZ SERIES. WATER FLOWS Water inlet temperatura ºC Model Condensing EWBT Cooling LWT WT LWT WT LWT WT LWT WT LWT WT Temp. ºC C Capacity C l/s C l/s C l/s C l/s C l/s 15 14,72 28,20 0,35 28,80 0,52 29,40 1, ,92 29,09 0,35 29,39 0,52 29,70 1, ,10 30,00 0,35 30,00 0,52 30,00 1, ,32 30,92 0,35 30,61 0,52 30,31 1, ,11 32,59 0,26 33,19 0,34 33,80 0,52 34,40 1, ,32 33,81 0,26 34,10 0,34 34,40 0,52 34,70 1, ,50 35,00 0,26 35,00 0,34 35,00 0,52 35,00 1,03 WCHBZ 21 17,71 36,21 0,26 35,91 0,34 35,61 0,52 35,30 1, ,46 36,95 0,20 37,56 0,26 38,17 0,34 38,78 0,51 39,39 1, ,66 38,47 0,20 38,78 0,26 39,08 0,34 39,39 0,51 39,69 1, ,86 40,00 0,20 40,00 0,26 40,00 0,34 40,00 0,51 40,00 1, ,07 41,52 0,20 41,21 0,26 40,91 0,34 40,61 0,51 40,30 1, ,80 41,32 0,17 41,93 0,20 42,54 0,25 43,16 0,34 38,77 0, ,98 43,16 0,17 43,47 0,20 43,77 0,25 44,08 0,34 44,39 0, ,18 45,00 0,17 45,00 0,20 45,00 0,25 45,00 0,34 45,00 0, ,35 46,80 0,17 46,50 0,20 46,20 0,25 45,90 0,34 45,60 0,51 NOTES: EWBT: Entering wet bulb temperature ºC LWT: Water outlet temperature WT: Water flow (l/s) PRESSURE DROP ON COAXIAL HEAT EXCHANGER (kpa) Water flow MODEL l/s 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 1,1 1,2 1,3 WCHBZ m 3 /h 0,4 0,7 1,1 1,4 1,8 2,2 2,5 2,9 3,2 3,6 4,0 4,3 4, ,5 5,8 10,5 18,5 24,0 33, ,5 5,8 10,5 18,5 24,0 33, ,5 2,5 4,0 8,0 11,0 15,0 20,0 26,0 32, ,5 2,5 4,0 8,0 11,0 15,0 20,0 26,0 32, ,0 3,7 7,0 8,5 12,0 16,0 21,0 25,0 28,0 33,0 37,5 42, Ref (En) Rev

16 WATER TO AIR HEAT PUMPS TUBE IN TUBE COAXIAL HEAT EXCHANGER WCHBZ SERIES. AIRFLOW STATIC PRESSURE MODEL WCHBz ADJ. PULLEY TURNS OPEN AIRFLOW m3/h l/s (1500) Pa W m3/h l/s (2000) Pa W m3/h l/s (2300) Pa W m3/h l/s (2400) Pa W (3500) 1 vuelta m3/h l/s Pa W Pa W Pa W NOTES: Airflow m 3 /h or l/s; Static pressure: Pa Ref (En) Rev. 103

17 WATER TO AIR HEAT PUMPS TUBE IN TUBE COAXIAL HEAT EXCHANGER WCHBZ SERIES. ACCESSORIES ROOM THERMOSTAT All models include room thermostat to control equipment operation. Mod 201 through 501: One stage Cooling/one stage Heating. KLR-E Type Option: Room sensor and duct sensor, DSL type. C O N T H E A T F A N F A N A U T O C O O L I O C KLRE On/Off 2. Temp. selection 3. Ventilation 4. Cool/Heat Selection DSL type (Option) 1. Mode. 2. Ventilation. 3. Temperature decrease. 4. Temperature increase. 5. Alternative setpoint. 3 4 ARIA CONTROLLER (Option) ARIA is a microprocessor electronic controller consisting of two elements: a terminal to be located in the room and a board located in the electric panel. Connection is made with only two wires. Parameters are configurated in the factory. BOARD Terminal max. 150 m LC Display MODE: cooling, heating, auto, fan, off FAN: selects fan operation, manual or auto SET: adjust of setpoints: comfort CLOCK: option with clock (programmable) RESUME: reset of alarms, etc Front buttons: allow for modification of setpoints Options - Remote sensor - Terminal with programmer clock Applications 1. STANDARD ALONE: one controller per unit 2. LAN: Local Area Network. To control up to 30 units. All information is centralized and controlled by means of a pco terminal. 3. Supervision & telemainenance Ref (En) Rev

18 WATER TO AIR HEAT PUMPS TUBE IN TUBE COAXIAL HEAT EXCHANGER WCHBZ SERIES. ACCESSORIES ELECTRIC HEATERS Made of nickel-chrome wire, mounted in a frame, incorporating thermal protection, contactor and terminal boards. Inside a plenum, ready to be fitted on the air supply DETAILS 1. Contactor 2. Connection terminals 3. Thermal protector MODEL Power kw 4 6 7,5 9,0 12 Voltage (50Hz~) V 230.I 230.III 400.III 230.I 230.III 400.III 230.I 230.III 400.III 230.I 230.III 400.III 230.III 400.III Input current A 17,4 10 5, ,1 8,7 32,6 18,8 10,8 39,1 22,8 13,1 30,1 17,3 WATER REGULATING VALVE Two way, pressure actuated water regulating valve, allowing water to flow to the heat exchanger to provide correct refrigerant head pressures. On heating operation, maximum waterflow is required; therefore, regulating valve has to be bypassed by means of a Solenoid valve. MODEL Quantity Size (") 3/8 3/8 1/2 1/2 3/4 OTHER OPTIONS Clogged filter indication Smoke detector Compressor jacket Base support VARIATIONS ON STANDARD PRODUCTION (to be consulted) Precoated coils Uprated indoor fan Special filters Fault indications Other power supplies Inverted air supply & return Other possible variations on request (to be consulted) Specifications subject to change without previous notice Ref (En) Rev. 103 D.L.: B Gràfiques Ferpala s.l. Eduard Toldrà, Vilanova Ref i la Geltrú (En) Tel. 93 Rev

19 SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER) SERIES: WCHZ MODELS: 201, 251, 271, 351, 401, 501, 701, 721, 751 COOLING CAPACITIES OF: 6,4 TO 25,1 kw 1

20 2

21 CONTENTS Page Description... 4 Construction. Dimensions... 5 to 7 Technical Specifications... 8, 9 Cooling capacities to 12 Water volumes to 17 Pressure drops Airflow. Static pressure - Consumo motor...18, 19 Accessories to 22 Hitecsa Aire Acondicionado, S.L.Unipersonal 3

22 DESCRIPTION Description The WCHZ series are packaged horizontal ductable airconditioners with co-axial water cooled condenser, suitable to be fitted to an air duct distribution system. Units are delivered totally finished after a complete final run test, ready to be installed (air distribution duct, electric supply, control system, drain). Units contain an operation charge of R407c refrigerant. Design and lay-out provide great versatility for any installation as well as easy access for future maintenance. Cabinet Made of high quality galvanized steel plate, finished with electrostatically applied and oven-polymerized polyester powder for optimum resistance against corrosion. The assembly is internally lined with thermo-acoustic insulation. Refrigerant Circuit Made of copper tube, refrigeration quality, clean and dehydrated. Filter drier and Schrader Valves on high and low side are included. Brazing is made with silver alloy under inert atmosphere (nitrogen). Compressors Hermetic, reciprocating or Scroll depending upon models. Compressors incorporate internal inherent protection, oil charge and crankcase heater. All compressors are mounted on the unit base on vibration eliminators. Expansion Device Models up to 501 use a restrictor (piston with calibrated orifice). Rest of models use a thermostatic expansion valve. Air filter Made of polyurethane foam, washable. Fire class M1. Operation and control Room thermostat. Contactors for compressor and fan motor. Overloads for three-phase fan motor. High pressure switch (manual reset) and low pressure switch (automatic reset). Terminal block for supply and controller. Main switch. Options Electric heaters. Hot water heating coils. Water regulating valve. Compressor jacket. Etc. Electric Supply Models 201 to 351: 230V 1Ph 50 Hz~. Models 201 to 751: 400V. 3Ph. +N, 50 Hz~. Some models available at 230V 3Ph 50 (to be consulted). Evaporator coil Made of aluminium fins and 3/8 seamless copper tubing, mechanically expanded. Condenser Tube in tube type (co-axial), all copper, counterflow, water cooled. Fans Centrifugal fan that allows for air distribution duct system. Up to model 401 are direct drive motor ( ). Rest of models incorporate a 230/400V.3.50 motor. Transmission is made through pulleys and belt for airflow, static pressure regulation. Fans are of reduced sound level, incorporate prelubricated bearings and are statically and dynamically balanced. OPERATION LIMITS Indoor Air COOLING Water Inlet Temp. DB. WB. Standard 30 C 27 C 19 C Min. 15 C 21 C 15 C Max. 40 C 32 C 23 C 4

23 CONSTRUCTION. DIMENSIONS MOD. 201, 251, 271, 351, 401 J L F G I K E 11 C D 12 2 H N A B CONSTRUCTION DETAILS 1. Electric panel 2. Drainage 3/4" male 3. Air filter 4. Fan motor 5. Fan 6. Electric heater (option) 7. Evaporator coil 8. Hot water coil (option) 9. Condenser 10. Compressor 11. Electric supply 12. Water outlet 13. Water intlet 14. Pressostat Water outlet Water intlet M O P Q R DIMENSIONS (mm) MODEL A B C D E F G H I J K L M N O P Q R WATER CONNECTIONS MODEL Size (male) 1/2" 1/2" 1/2" 1/2" 3/4" APPROXIMATE WEIGHT (kg) MODEL Net weight Packed weight

24 CONSTRUCTION. DIMENSIONS MOD Water outlet Water inlet APPROXIMATE WEIGHT (kg) MODEL 501 Net weight 160 Packed weight 180 WATER CONNECTIONS MODEL 501 Size (male) 3/4" CONSTRUCTION DETAILS 1. Pressostat 2. Condenser 3. Electric panel 4. Evaporator coil 5. Hot water coil (option) 6. Electric heater (option) 7. Fan 8. Fan motor 9. Compressor 10. Drainage 3/4" male 11. Air filter 12. Water connections 13. Power supply 6

25 CONSTRUCTION. DIMENSIONS MOD. 701, 721 y ø Water outlet model 751 Water outlet model 721 Water inlet APPROXIMATE WEIGHT (kg) MODEL Net weight Packed weight CONSTRUCTION DETAILS 1. Electric panel 2. Compressor 3. Evaporator coil 4. Hot water coil (option) 5. Electric heater (option) 6. Fan 7. Fan motor 8. Condenser 9. Drainage 3/4" male 10. Air filter 11. Power supply 12. Pressostat WATER CONNECTIONS MODEL Size (male) 1" 1" 1" 7

26 TECHNICAL SPECIFICATIONS MODELO WCHZ Rated cooling capacity kw 6,4 8,1 9,0 11,3 13,4 COMPRESSOR Type Hermetic, reciprocating Voltage (50 Hz~) V 230.I 230.I 230.I 400.III 230.I 230.III 400.III 230.III 400.III Input power kw 1,62 2,12 2,22 2,83 3,64 Input current A 8,3 10,8 11,3 3,8 14,5 8,4 4,8 10,8 6,2 EVAPORATOR COIL Type Copper tubing coil and aluminium fins Front face area m 3 0,188 0,225 0,252 0,252 0,310 Fin spacing - tube Ø mm - (") 2,1 3/8 2,1 3/8 2,1 3/8 2,1 3/8 2,1 3/8 CONDENSER Type Tube in tube, co-axial, all copper Water connections Ø (") 1/2 1/2 1/2 1/2 1/2 EVAPORATOR FAN Type Centrifugal Model 9/7 DD 9/7 DD 9/9 DD 10/10 DD 10/10 DD Motor power kw 0,125 0,125 0,250 0,250 0,250 Voltage (50 Hz~) V 230.I Input current A 1,4 1,5 2,1 2,3 2,3 REFRIGERANT R407c - operating charge kg 1,10 1,30 1,30 1,40 2,40 GENERAL DATA FOR ELECTRIC INSTALLATION Voltage (50 Hz~) V 230.I 230.I 230.I 400.III 230.I 230.III 400.III 230.III 400.III Total input power (1) kw 2,10 2,70 2,80 3,30 4,40 Total input current (1) A 10,7 13,8 14,3 4,8 16,9 9,8 5,6 13,0 7,5 Max. input power (2) kw 2,51 3,23 3,35 3,95 5,26 Max. input current (2) A 12,8 16,5 17,1 5,7 20,2 11,7 6,7 15,6 8,9 Starting current A SOUND PRESSURE LEVEL (at 2 meters) Unit db (A) COOLING (Standard): condensing temperature 40 C; 27 C DB / 19 C. WB indoor temperature. 2. COOLING (Max.): condensing temperature 50 C. 8

27 TECHNICAL SPECIFICATIONS MODELO WCHZ Rated cooling capacity kw 16,0 20,6 22,2 25,1 COMPRESSOR Type Hermetic, reciprocat. SCROLL Voltage (50 Hz~) V 230.III 400.III 400.III 230.III 400.III 230.III 400.III Input power kw 4,10 4,10 5,60 4,45 4,45 7,20 7,20 Input current A 12,1 7,0 7,4 15,7 9,1 21,4 12,2 EVAPORATOR COIL Type Copper tubing coil and aluminium fins Front face area m 3 0,350 0,473 0,473 0,495 Fin spacing - tube Ø mm - (") 2,1-3/8 2,1-3/8 2,1-3/8 2,1-3/8 CONDENSER Type Tube in tube, co-axial, all copper Water connections Ø (") 3/ EVAPORATOR FAN Type Centrifugal Model 10/10 SS 12/9 SS 12/9 SS 12/9 SS Motor power kw 0,550 0,750 0,750 0,750 Voltage (50 Hz~) V 230.III 400.III 400.III 230.III 400.III 230.III 400.III Input current A 2,8 1,7 2,0 3,5 2,0 3,5 2,0 REFRIGERANT R407c - operating charge kg 2,70 2,80 2,80 3,90 GENERAL DATA FOR ELECTRIC INSTALLATION Voltage (50 Hz~) V 230.III 400.III 400.III 230.III 400.III 230.III 400.III Total input power (1) kw 5,20 6,55 6,20 7,70 Total input current (1) A 15,4 8,8 11,1 18,3 10,5 22,8 13,1 Max. input power (2) kw 6,22 7,83 7,41 9,23 Max. input current (2) A 18,4 10,6 13,3 21,9 12,6 27,3 15,7 Starting current A SOUND PRESSURE LEVEL (at 2 meters) Unit db (A) COOLING (Standard): condensing temperature 40 C; 27 C DB / 19 C. WB indoor temperature. 2. COOLING (Max.): condensing temperature 50 C. 9

28 COOLING CAPACITIES MODEL WCHZ201 WCHZ251 WCHZ271 Indoor airflow l/s Condensing temp. C INDOOR AIR. ENTERING WET BULB TEMPERATURE 15 C Total capacity kw 5,71 5,47 5,22 4,96 7,22 6,93 6,61 6,27 8,03 7,70 7,34 6,97 Input power kw 1,84 2,01 2,20 2,39 2,36 2,59 2,82 3,07 2,45 2,69 2,93 3,18 19 C 4,09 3,93 3,77 3,62 5,17 4,97 4,78 4,58 5,75 5,53 5,31 5,09 Sensible Heat E.D.B.T. 21 C 4,69 4,52 4,37 4,21 5,93 5,72 5,53 5,33 6,59 6,36 6,14 5,92 kw 23 C 5,29 5,13 4,98 4,82 6,69 6,49 6,30 6,10 7,44 7,21 7,00 6,78 25 C 5,71 5,47 5,22 4,96 7,22 6,93 6,61 6,27 8,03 7,70 7,34 6,97 INDOOR AIR. ENTERING WET BULB TEMPERATURE 17 C Total capacity kw 6,18 5,94 5,69 5,42 7,82 7,52 7,20 6,86 8,68 8,36 7,99 7,63 Input power kw 1,88 2,06 2,24 2,43 2,42 2,64 2,88 3,12 2,50 2,74 2,98 3,24 21 C 4,08 3,92 3,76 3,61 5,16 4,96 4,76 4,57 5,74 5,51 5,29 5,07 Sensible Heat E.D.B.T. 23 C 4,68 4,52 4,36 4,21 5,93 5,72 5,52 5,33 6,58 6,36 6,14 5,92 kw 25 C 5,28 5,12 4,96 4,81 6,68 6,48 6,28 6,09 7,43 7,20 6,98 6,77 27 C 5,89 5,73 5,56 5,42 7,45 7,25 7,04 6,86 8,28 8,05 7,82 7,62 INDOOR AIR. ENTERING WET BULB TEMPERATURE 19 C Total capacity kw 6,63 6,40 6,15 5,89 8,40 8,10 7,79 7,45 9,33 9,00 8,65 8,28 Input power kw 1,93 2,10 2,28 2,47 2,49 2,70 2,93 3,18 2,58 2,80 3,04 3,30 23 C 4,08 3,92 3,76 3,61 5,16 4,96 4,76 4,57 5,73 5,51 5,29 5,07 Sensible Heat E.D.B.T. 25 C 4,67 4,52 4,36 4,21 5,92 5,72 5,52 5,33 6,57 6,36 6,13 5,92 kw 27 C 5,28 5,12 4,96 4,81 6,68 6,48 6,28 6,09 7,42 7,20 6,98 6,76 29 C 5,89 5,73 5,57 5,42 7,45 7,25 7,05 6,86 8,28 8,05 7,83 7,62 INDOOR AIR. ENTERING WET BULB TEMPERATURE 21 C Total capacity kw 7,11 6,87 6,62 6,34 8,99 8,69 8,38 8,03 9,99 9,66 9,31 8,92 Input power kw 1,98 2,14 2,32 2,51 2,55 2,75 2,98 3,23 2,64 2,85 3,09 3,35 25 C 4,04 3,89 3,74 3,58 5,12 4,92 4,73 4,54 5,69 5,47 5,26 5,04 Sensible Heat E.D.B.T. 27 C 4,67 4,51 4,35 4,20 5,91 5,71 5,51 5,32 6,57 6,34 6,12 5,91 kw 29 C 5,26 5,11 4,95 4,80 6,66 6,47 6,26 6,07 7,40 7,18 6,96 6,75 31 C 5,88 5,72 5,56 5,41 7,44 7,24 7,03 6,84 8,26 8,04 7,81 7,60 NOTES: 1. Capacities are net after deduction of indoor fan motor heat. 2. E. D.B.T. indoor entering air dry bulb temperature ( C). CORRECTION FACTORS % Airflow Total capacity 0,95 0,97 1,03 1,05 Sensible capacity 0,92 0,96 1,04 1,07 Input power 0,96 0,98 1,02 1,03 10

29 COOLING CAPACITIES MODEL WCHZ351 WCHZ401 WCHZ501 Indoor airflow l/s Condensing temp. C INDOOR AIR. ENTERING WET BULB TEMPERATURE 15 C Total capacity kw 10,08 9,67 9,22 8,75 11,95 11,46 10,93 10,38 14,27 13,69 13,05 12,39 Input power kw 2,89 3,17 3,45 3,75 3,85 4,22 4,60 5,00 4,55 4,99 5,44 5,91 19 C 7,22 6,94 6,66 6,39 8,56 8,23 7,90 7,57 10,54 10,13 9,73 9,32 Sensible Heat E.D.B.T. 21 C 8,28 7,98 7,71 7,43 9,82 9,47 9,14 8,82 12,09 11,66 11,26 10,85 kw 23 C 9,34 9,06 8,78 8,51 11,07 10,74 10,42 10,10 13,63 13,23 12,83 12,39 25 C 10,08 9,67 9,22 8,75 11,95 11,46 10,93 10,38 14,27 13,69 13,05 12,39 INDOOR AIR. ENTERING WET BULB TEMPERATURE 17 C Total capacity kw 10,90 10,49 10,04 9,57 12,93 12,44 11,90 11,35 15,44 14,85 14,21 13,56 Input power kw 2,95 3,23 3,52 3,82 3,94 4,31 4,69 5,09 4,65 5,09 5,54 6,02 21 C 7,20 6,92 6,64 6,37 8,54 8,21 7,87 7,56 10,52 10,11 9,70 9,30 Sensible Heat E.D.B.T. 23 C 8,27 7,99 7,70 7,43 9,80 9,47 9,13 8,82 12,07 11,66 11,25 10,86 kw 25 C 9,33 9,04 8,76 8,50 11,06 10,72 10,39 10,08 13,62 13,21 12,79 12,4 27 C 10,40 10,11 9,82 9,57 12,33 11,99 11,65 11,34 15,18 14,77 14,21 13,56 INDOOR AIR. ENTERING WET BULB TEMPERATURE 19 C Total capacity kw 11,71 11,30 10,86 10,40 13,89 13,40 12,88 12,33 16,58 16,00 15,38 14,72 Input power kw 3,04 3,30 3,58 3,89 4,05 4,40 4,78 5,18 4,79 5,20 5,65 6,12 23 C 7,20 6,92 6,64 6,37 8,53 8,20 7,87 7,55 10,51 10,10 9,69 9,30 Sensible Heat E.D.B.T. 25 C 8,25 7,98 7,70 7,43 9,79 9,47 9,13 8,81 12,05 11,66 11,25 10,85 kw 27 C 9,32 9,04 8,76 8,49 11,05 10,72 10,39 10,07 13,61 13,20 12,79 12,40 29 C 10,39 10,11 9,83 9,56 12,32 11,99 11,66 11,34 15,17 14,77 14,36 13,96 INDOOR AIR. ENTERING WET BULB TEMPERATURE 21 C Total capacity kw 12,55 12,13 11,69 11,20 14,88 14,38 13,86 13,28 17,77 17,17 16,55 15,86 Input power kw 3,11 3,36 3,64 3,95 4,15 4,49 4,85 5,26 4,90 5,30 5,74 6,22 25 C 7,14 6,87 6,60 6,33 8,47 8,15 7,83 7,50 10,43 10,03 9,64 9,24 Sensible Heat E.D.B.T. 27 C 8,24 7,96 7,68 7,42 9,77 9,44 9,11 8,79 12,04 11,63 11,22 10,83 kw 29 C 9,30 9,02 8,74 8,47 11,02 10,70 10,36 10,05 13,57 13,17 12,76 12,37 31 C 10,37 10,09 9,81 9,55 12,30 11,97 11,63 11,32 15,15 14,74 14,33 13,94 NOTES: 1. Capacities are net after deduction of indoor fan motor heat. 2. E. D.B.T. indoor entering air dry bulb temperature ( C). CORRECTION FACTORS % Airflow Total capacity 0,95 0,97 1,03 1,05 Sensible capacity 0,92 0,96 1,04 1,07 Input power 0,96 0,98 1,02 1,03 11

30 COOLING CAPACITIES MODEL WCHZ701 WCHZ721 WCHZ751 Indoor airflow l/s Condensing temp. C INDOOR AIR. ENTERING WET BULB TEMPERATURE 15 C Total capacity kw 18,37 17,62 16,80 15,95 19,80 18,99 18,11 17,19 22,39 21,47 20,48 19,44 Input power kw 5,73 6,28 6,85 7,45 5,43 5,95 6,48 7,05 6,74 7,39 8,05 8,76 19 C 13,15 12,65 12,15 11,64 14,17 13,63 13,09 12,55 16,03 15,41 14,80 14,19 Sensible Heat E.D.B.T. 21 C 15,09 14,55 14,06 13,55 16,26 15,68 15,15 14,60 18,39 17,73 17,13 16,51 kw 23 C 17,02 16,51 16,01 15,52 18,34 17,80 17,26 16,73 20,74 20,12 19,51 18,91 25 C 18,37 17,62 16,80 15,95 19,80 18,99 18,11 17,19 22,39 21,47 20,48 19,44 INDOOR AIR. ENTERING WET BULB TEMPERATURE 17 C Total capacity kw 19,88 19,12 18,30 17,46 21,42 20,61 19,72 18,81 24,22 23,30 22,30 21,27 Input power kw 5,86 6,41 6,98 7,58 5,55 6,07 6,60 7,17 6,89 7,54 8,20 8,91 21 C 13,13 12,62 12,10 11,61 14,15 13,60 13,04 12,52 16,00 15,38 14,75 14,15 Sensible Heat E.D.B.T. 23 C 15,07 14,56 14,04 13,55 16,24 15,69 15,13 14,61 18,36 17,74 17,11 16,51 kw 25 C 17,00 16,49 15,97 15,50 18,32 17,77 17,21 16,70 20,71 20,09 19,46 18,88 27 C 18,96 18,43 17,91 17,44 20,43 19,87 19,30 18,79 23,10 22,46 21,82 21,25 INDOOR AIR. ENTERING WET BULB TEMPERATURE 19 C Total capacity kw 21,35 20,60 19,80 18,95 23,01 22,20 21,34 20,43 26,02 25,10 24,13 23,10 Input power kw 6,03 6,55 7,11 7,71 5,71 6,20 6,73 7,30 7,09 7,70 8,36 9,07 23 C 13,12 12,61 12,10 11,61 14,14 13,59 13,04 12,51 15,99 15,37 14,75 14,15 Sensible Heat E.D.B.T. 25 C 15,05 14,55 14,04 13,55 16,21 15,68 15,13 14,60 18,33 17,73 17,11 16,51 kw 27 C 16,99 16,48 15,97 15,48 18,31 17,76 17,21 16,68 20,70 20,08 19,46 18,86 29 C 18,94 18,44 17,92 17,43 20,41 19,87 19,32 18,79 23,08 22,46 21,84 21,24 INDOOR AIR. ENTERING WET BULB TEMPERATURE 21 C Total capacity kw 22,87 22,11 21,31 20,41 24,65 23,82 22,97 22,00 27,87 26,93 25,97 24,87 Input power kw 6,18 6,68 7,22 7,83 5,85 6,32 6,84 7,41 7,26 7,85 8,49 9,21 25 C 13,02 12,52 12,03 11,54 14,03 13,50 12,96 12,43 15,86 15,26 14,66 14,06 Sensible Heat E.D.B.T. 27 C 15,03 14,52 14,00 13,52 16,19 15,64 15,09 14,57 18,31 17,69 17,06 16,47 kw 29 C 16,95 16,44 15,93 15,45 18,26 17,72 17,17 16,65 20,65 20,04 19,41 18,82 31 C 18,91 18,40 17,89 17,40 20,38 19,83 19,28 18,76 23,04 22,42 21,79 21,21 NOTES: 1. Capacities are net after deduction of indoor fan motor heat. 2. E. D.B.T. indoor entering air dry bulb temperature ( C). CORRECTION FACTORS % Airflow Total capacity 0,95 0,97 1,03 1,05 Sensible capacity 0,92 0,96 1,04 1,07 Input power 0,96 0,98 1,02 1,03 12

31 CONDENSER WATER FLOW Water inlet temperatur C MODEL Condensing EWBT Cooling LWT WT LWT WT LWT WT LWT WT LWT WT temp. C C cap. C l/s C l/s C l/s C l/s C l/s 15 5,71 28,23 0,14 28,82 0,20 29,41 0, ,18 29,12 0,14 29,42 0,20 29,71 0, ,63 30,00 0,14 30,00 0,20 30,00 0, ,11 30,93 0,14 30,62 0,20 30,31 0, ,47 32,60 0,10 33,20 0,14 33,80 0,20 34,40 0, ,94 33,82 0,10 34,12 0,14 34,41 0,20 34,71 0, ,40 35,00 0,10 35,00 0,14 35,00 0,20 35,00 0,41 WCHZ 21 6,87 36,20 0,10 35,90 0,14 35,60 0,20 35,30 0, ,22 37,00 0,08 37,60 0,10 38,20 0,13 38,80 0,20 39,40 0, ,69 38,52 0,08 38,81 0,10 39,11 0,13 39,41 0,20 39,70 0, ,15 40,00 0,08 40,00 0,10 40,00 0,13 40,00 0,20 40,00 0, ,62 41,51 0,08 41,21 0,10 40,91 0,13 40,60 0,20 40,30 0, ,96 41,38 0,07 41,98 0,08 42,58 0,10 43,19 0,13 43,79 0, ,42 43,17 0,07 43,47 0,08 43,78 0,10 44,08 0,13 44,39 0, ,89 45,00 0,07 45,00 0,08 45,00 0,10 45,00 0,13 45,00 0, ,34 46,76 0,07 46,47 0,08 46,17 0,10 45,88 0,13 45,59 0, ,22 28,20 0,17 28,80 0,26 29,40 0, ,82 29,10 0,17 29,40 0,26 29,70 0, ,40 30,00 0,17 30,00 0,26 30,00 0, ,99 30,90 0,17 30,60 0,26 30,30 0, ,93 32,63 0,13 33,22 0,17 33,81 0,26 34,41 0, ,52 33,81 0,13 34,11 0,17 34,41 0,26 34,70 0, ,10 35,00 0,13 35,00 0,17 35,00 0,26 35,00 0,52 WCHZ 21 8,69 36,19 0,13 35,89 0,17 35,59 0,26 35,30 0, ,61 36,99 0,10 37,59 0,13 38,19 0,17 38,80 0,26 39,40 0, ,20 38,51 0,10 38,81 0,13 39,10 0,17 39,40 0,26 39,70 0, ,79 40,00 0,10 40,00 0,13 40,00 0,17 40,00 0,26 40,00 0, ,38 41,49 0,10 41,19 0,13 40,90 0,17 40,60 0,26 40,30 0, ,27 41,36 0,08 41,97 0,10 42,57 0,13 43,18 0,17 43,79 0, ,86 43,17 0,08 43,47 0,10 43,78 0,13 44,08 0,17 44,39 0, ,45 45,00 0,08 45,00 0,10 45,00 0,13 45,00 0,17 45,00 0, ,03 46,78 0,08 46,48 0,10 46,19 0,13 45,89 0,17 45,59 0,25 NOTES: EWBT= indoor air entering wet bulb temperature ºC. LWT= leaving water temperature ºC. WT= water flow l/s. 13

32 CONDENSER WATER FLOW Water inlet temperatur C MODEL Condensing EWBT Cooling LWT WT LWT WT LWT WT LWT WT LWT WT temp. C C cap. C l/s C l/s C l/s C l/s C l/s 15 8,03 28,20 0,19 28,80 0,28 29,40 0, ,68 29,08 0,19 29,39 0,28 29,69 0, ,33 30,00 0,19 30,00 0,28 30,00 0, ,99 30,91 0,19 30,60 0,28 30,30 0, ,70 32,61 0,14 33,21 0,19 33,81 0,28 34,40 0, ,36 33,81 0,14 34,11 0,19 34,41 0,28 34,70 0, ,00 35,00 0,14 35,00 0,19 35,00 0,28 35,00 0,56 WCHZ 21 9,66 36,20 0,14 35,90 0,19 35,60 0,28 35,30 0, ,34 36,96 0,11 37,57 0,14 38,18 0,19 38,79 0,28 39,39 0, ,99 38,46 0,11 38,77 0,14 39,08 0,19 39,38 0,28 39,69 0, ,65 40,00 0,11 40,00 0,14 40,00 0,19 40,00 0,28 40,00 0, ,31 41,52 0,11 41,21 0,14 40,91 0,19 40,61 0,28 40,30 0, ,18 41,30 0,09 41,91 0,11 42,53 0,14 43,15 0,18 43,77 0, ,63 43,16 0,09 43,47 0,11 43,77 0,14 44,08 0,18 44,39 0, ,28 45,00 0,09 45,00 0,11 45,00 0,14 45,00 0,18 45,00 0, ,92 46,79 0,09 46,49 0,11 46,19 0,14 45,89 0,18 45,60 0, ,08 28,19 0,23 28,79 0,35 29,40 0, ,90 29,08 0,23 29,39 0,35 29,69 0, ,71 30,00 0,23 30,00 0,35 30,00 0, ,55 30,93 0,23 30,62 0,35 30,31 0, ,67 32,59 0,17 33,19 0,23 33,79 0,35 34,40 0, ,49 33,79 0,17 34,10 0,23 34,40 0,35 34,70 0, ,30 35,00 0,17 35,00 0,23 35,00 0,35 35,00 0,70 WCHZ 21 12,13 36,22 0,17 35,91 0,23 35,61 0,35 35,30 0, ,22 36,94 0,14 37,55 0,17 38,16 0,23 38,77 0,34 39,39 0, ,04 38,48 0,14 38,78 0,17 39,09 0,23 39,39 0,34 39,70 0, ,86 40,00 0,14 40,00 0,17 40,00 0,23 40,00 0,34 40,00 0, ,69 41,54 0,14 41,23 0,17 40,92 0,23 40,62 0,34 40,31 0, ,75 41,24 0,11 41,87 0,14 42,49 0,17 43,12 0,23 43,75 0, ,57 43,11 0,11 43,43 0,14 43,74 0,17 44,06 0,23 44,37 0, ,40 45,00 0,11 45,00 0,14 45,00 0,17 45,00 0,23 45,00 0, ,20 46,81 0,11 46,50 0,14 46,20 0,17 45,90 0,23 45,60 0,34 NOTES: EWBT= indoor air entering wet bulb temperature ºC. LWT= leaving water temperature ºC. WT= water flow l/s. 14

33 CONDENSER WATER FLOW Water inlet temperatur C MODEL Condensing EWBT Cooling LWT WT LWT WT LWT WT LWT WT LWT WT temp. C C cap. C l/s C l/s C l/s C l/s C l/s ,95 28,21 0,29 28,81 0,43 29,40 0, ,93 29,11 0,29 29,40 0,43 29,70 0, ,89 30,00 0,29 30,00 0,43 30,00 0, ,88 30,91 0,29 30,61 0,43 30,30 0, ,46 32,62 0,21 33,21 0,28 33,81 0,43 34,40 0, ,44 33,82 0,21 34,12 0,28 34,41 0,43 34,71 0, ,40 35,00 0,21 35,00 0,28 35,00 0,43 35,00 0,85 WCHZ 21 14,38 36,20 0,21 35,90 0,28 35,60 0,43 35,30 0, ,93 36,98 0,17 37,59 0,21 38,19 0,28 38,79 0,42 39,40 0, ,90 38,49 0,17 38,79 0,21 39,09 0,28 39,39 0,42 39,70 0, ,88 40,00 0,17 40,00 0,21 40,00 0,28 40,00 0,42 40,00 0, ,86 41,49 0,17 41,19 0,21 40,89 0,28 40,59 0,42 40,30 0, ,38 41,35 0,14 41,96 0,17 42,57 0,21 43,18 0,28 43,78 0, ,35 43,17 0,14 43,47 0,17 43,78 0,21 44,08 0,28 44,39 0, ,33 45,00 0,14 45,00 0,17 45,00 0,21 45,00 0,28 45,00 0, ,28 46,76 0,14 46,47 0,17 46,18 0,21 45,88 0,28 45,59 0, ,27 28,21 0,34 28,81 0,51 29,40 1, ,44 29,10 0,34 29,40 0,51 29,70 1, ,58 30,00 0,34 30,00 0,51 30,00 1, ,77 30,91 0,34 30,61 0,51 30,30 1, ,69 32,62 0,25 33,22 0,34 33,81 0,51 34,41 1, ,85 33,81 0,25 34,11 0,34 34,41 0,51 34,70 1, ,00 35,00 0,25 35,00 0,34 35,00 0,51 35,00 1,01 WCHZ 21 17,17 36,20 0,25 35,90 0,34 35,60 0,51 35,30 1, ,05 36,98 0,20 37,58 0,25 38,19 0,33 38,79 0,50 39,40 1, ,21 38,48 0,20 38,78 0,25 39,09 0,33 39,39 0,50 39,70 1, ,38 40,00 0,20 40,00 0,25 40,00 0,33 40,00 0,50 40,00 1, ,55 41,50 0,20 41,20 0,25 40,90 0,33 40,60 0,50 40,30 1, ,91 41,34 0,17 41,95 0,20 42,56 0,25 43,17 0,33 43,78 0, ,56 43,19 0,17 43,49 0,20 43,79 0,25 44,09 0,33 44,40 0, ,72 45,00 0,17 45,00 0,20 45,00 0,25 45,00 0,33 45,00 0, ,86 46,79 0,17 46,49 0,20 46,19 0,25 45,89 0,33 45,60 0,50 NOTES: EWBT= indoor air entering wet bulb temperature ºC. LWT= leaving water temperature ºC. WT= water flow l/s. 15

34 CONDENSER WATER FLOW Water inlet temperatur C MODEL Temperatura de EWBT Potencia LWT WT LWT WT LWT WT LWT WT LWT WT condensación C C frigorífica C l/s C l/s C l/s C l/s C l/s 15 18,37 28,20 0,44 28,80 0,65 29,40 1, ,88 29,10 0,44 29,40 0,65 29,70 1, ,35 30,00 0,44 30,00 0,65 30,00 1, ,87 30,91 0,44 30,61 0,65 30,30 1, ,62 32,61 0,32 33,20 0,43 33,80 0,65 34,40 1, ,12 33,81 0,32 34,10 0,43 34,40 0,65 34,70 1, ,60 35,00 0,32 35,00 0,43 35,00 0,65 35,00 1,30 WCHZ 21 22,11 36,21 0,32 35,91 0,43 35,60 0,65 35,30 1, ,80 36,97 0,26 37,58 0,32 38,18 0,43 38,79 0,64 39,39 1, ,30 38,49 0,26 38,79 0,32 39,09 0,43 39,39 0,64 39,70 1, ,80 40,00 0,26 40,00 0,32 40,00 0,43 40,00 0,64 40,00 1, ,31 41,51 0,26 41,20 0,32 40,90 0,43 40,60 0,64 40,30 1, ,95 41,33 0,21 41,94 0,25 42,55 0,32 43,17 0,42 43,78 0, ,46 43,18 0,21 43,48 0,25 43,78 0,32 44,09 0,42 44,39 0, ,95 45,00 0,21 45,00 0,25 45,00 0,32 45,00 0,42 45,00 0, ,41 46,78 0,21 46,48 0,25 46,19 0,32 45,89 0,42 45,59 0, ,80 28,18 0,46 28,78 0,69 29,39 1, ,42 29,09 0,46 29,39 0,69 29,70 1, ,01 30,00 0,46 30,00 0,69 30,00 1, ,65 30,93 0,46 30,62 0,69 30,31 1, ,99 32,56 0,34 33,17 0,45 33,78 0,68 34,39 1, ,61 33,79 0,34 34,09 0,45 34,39 0,68 34,70 1, ,20 35,00 0,34 35,00 0,45 35,00 0,68 35,00 1,36 WCHZ 21 23,82 36,23 0,34 35,92 0,45 35,61 0,68 35,31 1, ,11 36,90 0,27 37,52 0,34 38,14 0,45 38,76 0,67 39,38 1, ,72 38,44 0,27 38,75 0,34 39,06 0,45 39,38 0,67 39,69 1, ,34 40,00 0,27 40,00 0,34 40,00 0,45 40,00 0,67 40,00 1, ,97 41,55 0,27 41,24 0,34 40,93 0,45 40,62 0,67 40,31 1, ,19 41,22 0,22 41,85 0,26 42,48 0,33 43,11 0,44 43,74 0, ,81 43,11 0,22 43,42 0,26 43,74 0,33 44,05 0,44 44,37 0, ,43 45,00 0,22 45,00 0,26 45,00 0,33 45,00 0,44 45,00 0, ,00 46,82 0,22 46,51 0,26 46,21 0,33 45,91 0,44 45,61 0,66 NOTES: EWBT= indoor air entering wet bulb temperature ºC. LWT= leaving water temperature ºC. WT= water flow l/s. 16

35 CONDENSER WATER FLOW. PRESSURE DROPS Water inlet temperatur C MODEL Condensing EWBT Cooling LWT WT LWT WT LWT WT LWT WT LWT WT temp. C C cap. C l/s C l/s C l/s C l/s C l/s 15 22,39 28,20 0,53 28,80 0,79 29,40 1, ,22 29,09 0,53 29,40 0,79 29,70 1, ,02 30,00 0,53 30,00 0,79 30,00 1, ,87 30,92 0,53 30,61 0,79 30,31 1, ,47 32,60 0,39 33,20 0,52 33,80 0,78 34,40 1, ,30 33,80 0,39 34,10 0,52 34,40 0,78 34,70 1, ,10 35,00 0,39 35,00 0,52 35,00 0,78 35,00 1,57 WCHZ 21 26,93 36,21 0,39 35,91 0,52 35,60 0,78 35,30 1, ,48 36,95 0,31 37,56 0,39 38,17 0,52 38,78 0,78 39,39 1, ,30 38,47 0,31 38,78 0,39 39,08 0,52 39,39 0,78 39,69 1, ,13 40,00 0,31 40,00 0,39 40,00 0,52 40,00 0,78 40,00 1, ,97 41,52 0,31 41,21 0,39 40,91 0,52 40,61 0,78 40,30 1, ,76 41,30 0,26 41,91 0,31 42,53 0,38 43,15 0,51 43,77 0, ,27 43,14 0,26 43,45 0,31 43,76 0,38 44,07 0,51 44,38 0, ,10 45,00 0,26 45,00 0,31 45,00 0,38 45,00 0,51 45,00 0, ,87 46,78 0,26 46,48 0,31 46,19 0,38 45,89 0,51 45,59 0,77 NOTES: EWBT= indoor air entering wet bulb temperature ºC. LWT= leaving water temperature ºC. WT= water flow l/s. PRESSURE DROP ON CONDENSER (KPA) WATER FLOW MODEL l/s 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 1,1 1,2 1,3 1,4 1,5 1,6 WCHZ m 3 /h 0,4 0,7 1,1 1,4 1,8 2,2 2,5 2,9 3,2 3,6 4,0 4,3 4,7 5,0 5,4 5, ,5 5,8 10,5 18,5 24,0 33, ,5 5,8 10,5 18,5 24,0 33, ,5 5,8 10,5 18,5 24,0 33, ,5 2,5 4,0 8,0 11,0 15,0 20,0 26,0 32, ,5 2,5 4,0 8,0 11,0 15,0 20,0 26,0 32, ,0 3,7 7,0 8,5 12,0 16,0 21,0 25,0 28,0 33,0 37,5 42, ,0 3,7 7,0 8,5 12,0 16,0 21,0 25,0 28,0 33,0 37,5 42, ,0 3,7 7,0 8,5 12,0 16,0 21,0 25,0 28,0 33,0 37,5 42,0 45, ,0 2,0 3,0 6,0 7,0 8,3 10,0 13,0 17,0 21,0 26,0 35,0 40,0 50,0 55,0 17

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER) SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER) SERIES: WCHZ MODELS: 201, 251, 271, 351, 401, 501, 701, 721, 751 COOLING CAPACITIES OF: 6,4

More information

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5

More information

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY CONDENSING UNITS. AIR COOLED CONDENSER. CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY SERIES: DXCZ MODELS: 171, 201, 221, 251, 271, 351 371, 401, 451, 501, 701 and 721 COOLING CAPACITIES OF: 4,7

More information

TECHNICAL CATALOGUE SELF-CONTAINED VERTICAL UNITS AIR / AIR DC INVERTER

TECHNICAL CATALOGUE SELF-CONTAINED VERTICAL UNITS AIR / AIR DC INVERTER TECHNICAL CATALOGUE SELF-CONTAINED VERTICAL UNITS AIR / AIR DC INVERTER Models : 601, 741, 901 ACVIA - Cooling only (Compact) CCVIA / ECVIA - Cooling only (Split) ACVIBA - Heat Pump (Compact) CCVIBA /

More information

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw Vertical Air-Cooled Split-System Cooling Units Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. 50VZ (40PZ/38VZ)

More information

ECV SP GUE ALO CAT ICAL TECHN

ECV SP GUE ALO CAT ICAL TECHN TECHNICAL CATALOGUE ECV SP TAILOR MADE FOR UNITS FITTED WITH VRF SYSTEMS Models: 1001 1502 1602 2003 2303 10.16 Ref. 207609 Rev.105 CONTENT INTRODUCTION... 3 GENERAL DESCRIPTION... 3 CABINET... 3 HEAT

More information

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01 b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Compact, Self-Contained unit that offer low installation cost plus dependable performance. 0 Compact, Self-Contained unit that offer low installation cost plus dependable performance. From carrier s excellence in engineering come a new, compact of single package horizontal and vertical water

More information

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS Cooling Capacity from 115,000 to 670,000 Btu/hr Btu/hr Smartwise Innovations... Towards Green, Quality & Reliability Solutions SERIES INTRODUCTION

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED

More information

EHW KH PF HIGH EFFICIENTY AIR CONDITONING UNITS TECHNICAL CATALOGUE

EHW KH PF HIGH EFFICIENTY AIR CONDITONING UNITS TECHNICAL CATALOGUE TECHNICAL CATALOGUE EHW KH PF HIGH EFFICIENTY AIR CONDITONING Models: 518 725 830 1036 1042 1657 Cooling Capacities: 18, 6 to 54, 4 KW Heating Capacities: 24, 1 to 71 KW 01.16 Ref. 207520 Rev. 101 INDEX

More information

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Большая библиотека технической документации   каталоги, инструкции, сервисные мануалы, схемы. Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive,

More information

ROOF TOP TYPE UNITS CENTRIFUGAL FANS ENGINEERING DATA MANUAL MODELS Rev. 100

ROOF TOP TYPE UNITS CENTRIFUGAL FANS ENGINEERING DATA MANUAL MODELS Rev. 100 RCCA Cooling only RCCBA Heat pump ENGINEERING DATA MANUAL MODELS 1402 1602 2002 2402 3002 04.14 207402 Rev. 100 Thank you for trust in HITECSA Product. From our company we are offering to the market, for

More information

E U R O V E N T CERTIFIED PERFORMANCE

E U R O V E N T CERTIFIED PERFORMANCE Compact Horizontal Air-Air Heat Pump Model RTH-7K to 3K Ref.: Y-R719 7 Technical information E U R O V E N T CERTIFIED PERFORMANCE I S O 9 1 ER-8/1991 Clima Roca York S.L. is participating in the EUROVENT

More information

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10 Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW Compressors Scroll Serie: Series: Emissione: Issue: SCAEY Catalogo: Leaflet: Sostituisce: Supersedes: DE 88 04/11 12/10 Index

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

Condensing Units CUS 15-60

Condensing Units CUS 15-60 Condensing Units CUS 15-60 General Description UNIT IDENTIFICATION AIR COOLED CONDENSING UNIT CUS... Condensing Unit with Propeller Fan and Scroll Compressor 15-60... Model Size D... Double Circuit e.g....

More information

EMI ENGINEERING SUBMITTAL

EMI ENGINEERING SUBMITTAL (MH4) MULTI-ZONE HEAT PUMP AIR CONDITIONING SYSTEM Rev. 1.4 [3/05] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: UNIT DESIGNATION:

More information

30GT FLOTRONIC AIR-COOLED CHILLERS

30GT FLOTRONIC AIR-COOLED CHILLERS 30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models: INSTALLATION, OPERATION AND MAINTENANCE MANUAL BHW MEDIUM STATIC PRESSURE DUCTABLE TYPE Models: 174 205 358 410 515 720 724 Cooling capacities from 3,1 to 25 KW Heating capacities from 4,5 to 55,5 KW Thank

More information

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES Range 3.6 To 36.5 Tons 50Hz R22 TABLE OF CONTENT General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators

More information

CHAPTER 6 CONDENSING UNITS

CHAPTER 6 CONDENSING UNITS CHAPTER CONDENSING UNITS Unit Page MHA/K - MHA/K 8 0 - MRA/K 8-9 MRA/K 8 0 0 - FROM, KW TO KW. MHA/K AIRCOOLED CONDENSING UNITS AND REVERSIBLE CONDENSING UNITS WITH AXIAL FANS AND ROTARY/SCROLL COMPRESSOR.

More information

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units

More information

30GN FLOTRONIC II AIR-COOLED CHILLERS

30GN FLOTRONIC II AIR-COOLED CHILLERS 30GN-19SB 30GN040-110 FLOTRONIC II AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GN-19SB Supersedes 30GN-6SB, 30GN-7SB, 30GN-8SB, Printed

More information

AQUASNAP JUNIOR 30RHV

AQUASNAP JUNIOR 30RHV High-Efficiency Air-To-Water Heat Pumps Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. AQUASNAP JUNIOR 3RHV 6-11

More information

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with

More information

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Indoor Single Package Vertical, Air-Cooled Heat Pump Unit RetroAire Model Number: Capacity Range: VPRH 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Part 1 General 1.01 UNIT DESCRIPTION A. Indoor, single package

More information

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece

More information

Highly Efficient,Powerful Heating and Cooling.

Highly Efficient,Powerful Heating and Cooling. AIR-COOLED ROOFTOP PACKAGED AIR CONDITIONERS Series HEAT PUMP PRHG-8,,,20 Cooling Capacity kw Heating Capacity kw PRHG-8 PRHG- PRHG- PRHG-20 PRHG-8 PRHG- PRHG- PRHG-20 23.8 29.7.3 60.8 23.0 32.0 45.5 61.2

More information

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED Your Climate. We're There. TM: MDB B 2140B Ducted Split Systems Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR REGISTERED Air Conditioning Contents Nomenclature System... 2 Features... 2 General Specifications...3-5

More information

CONFORME NORMAS ISO 9001 CONFORM ISO 9001 NORMEN ER-028/1/91 CONFORME NORMAS ISO 9001 CONFORM ISO 9001 NORMEN

CONFORME NORMAS ISO 9001 CONFORM ISO 9001 NORMEN ER-028/1/91 CONFORME NORMAS ISO 9001 CONFORM ISO 9001 NORMEN Air-cooled split air Conditioners AHO-F / ASAI, CHI Ref.: N-26643 0996 Technical information ire Acondicionado ACCORDING TO ISO 9001 STANDARDS 28/1/91 ER-028/1/91 CONFORME AUX NORMES ISO 9001 ER-028/1/91

More information

www.ecso-klimatechnik.de ECSO GMBH Wetterssteimstr. 53 D- 90471,.. Nurnberg, Deutschland e-mail: info@ecso-klimatechnik.de Tel/Fax: +49 (0) 911/818 9917 TABLE OF SYMBOLS OPERATING MODE OPTIONS VENTILATION

More information

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make. All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing

More information

ROOFTOP PACKAGED AIR CONDITIONERS

ROOFTOP PACKAGED AIR CONDITIONERS ROOFTOP PACKAGED AIR CONDITIONERS Rooftop Packaged Air Conditioners Hitachi has long been a world leader in the design and manufacture of quality air conditioning systems. With models ranging from room

More information

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort Application guide FLATAIR - FLCK/FLHK Providing indoor climate comfort MSL60E-0701 12-2006 Congratulations you have made a wise choice and we feel sure that it will meet your expectation INDEX CONTENTS

More information

Roof top SPACE RPC 450Z R407C M011

Roof top SPACE RPC 450Z R407C M011 Roof top SPACE RPC 450Z R407C M011 Page : 1 / 5 Independant roof mounted unit, cooling only, ready to be installed, designed for air conditioning of large volumes for industrial or commercial use. As per

More information

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental TECAM S.A. Tecnología Ambiental R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz harmony 5PZA Direct Expansion Registration No.: SC 4696-1 Registration No.: CO-SC 4696-1 Air Conditioning Equipment Manufacturer

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

Chiller units and air-water heat pumps RANGE OPERATING LIMITS Chiller units and air-water heat pumps Cooling capacity: Heating capacity: 6, to 6,6 kw 8, to 69,4 kw ENVIRONMENTALLY FRIENDLY HFC R407C PROTECTION DE L'ENVIRONNEMENT Silent and compact design Air-conditioning

More information

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw] PC SERIES 50 Hertz Self-Contained Packaged Air Conditioners 4 and 5 Ton [14.1 kw to 17.6 kw] Nominal Cooling Capacity: 48,000 to 60,000 BTUH The PC 50 Hz self-contained packaged air conditioners are designed

More information

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT 1. GENERAL INFORMATION 1.1 Applications page 2 1.2 Operation» 2 1.3 Performances» 2 1.4 Product range» 2 1.5 Selection software» 2 2. DIMENSIONS AND WEIGHTS» 3 3. COMPONENTS 3.1 Structure» 4 3.2 Coils»

More information

Guide Specifications PART 1 GENERAL 1.01 SUMMARY

Guide Specifications PART 1 GENERAL 1.01 SUMMARY Guide Specifications PART 1 GENERAL 1.01 SUMMARY A The environmental control system shall be designed specifically for precision temperature control applications. It will automatically monitor and control

More information

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017 Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air

More information

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1 UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information

VariCool VAV Engineering Guide

VariCool VAV Engineering Guide Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control

More information

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump VertiCool CLASSIC Engineering Guide Effective March 2018 Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump Contents Product Features... 3 UNIT FEATURES... 3 OPTIONS:... 3 Physical Data...

More information

APPLICATION GUIDE FLATAIR FMC - H FIC - H FSC - H. Horizontal packaged air conditioners kw FLATAIR AGU-MSL E. lennoxemeia.

APPLICATION GUIDE FLATAIR FMC - H FIC - H FSC - H. Horizontal packaged air conditioners kw FLATAIR AGU-MSL E. lennoxemeia. APPLICATION GUIDE FLATAIR FMC - H FIC - H FSC - H Horizontal packaged air conditioners 10 28 kw FLATAIR AGU-MSL60-1505-E lennoxemeia.com INDEX FLATAIR TM APPLICATION GUIDE Ref : FLATAIR AGU-MSL60-1505-E

More information

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C CONTENTS General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators Evaporator fan and drive Casing-Structure

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or

More information

50YZ 40BZ/38BZ Nominal cooling capacity kw Nominal heating capacity kw

50YZ 40BZ/38BZ Nominal cooling capacity kw Nominal heating capacity kw Single-Package Heat Pumps Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. 50YZ 40BZ/38BZ Nominal cooling capacity

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are

More information

EQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM

EQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM TECHNICAL CATALOGUE EQEF Water Chillers with Free Cooling System Models:60.1 60.2 70.1 70.2 90.1 90.2 120.1 120.2 135.1 150.1 190.2 200.1 200.2 240.2 270.2 300.2 Cooling capacities: 69,7 to 331 KW 02.16

More information

VertiCool Aurora Engineering Guide

VertiCool Aurora Engineering Guide Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8

More information

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating

More information

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,

More information

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT SECTION 23 81 00 DECENTRALIZED UNITARY HVAC EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes packaged roof top unit, unit controls, remote panel, roof mounting curb and base, maintenance service,

More information

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01

More information

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES LS ir cooled water chillers with axial fans + LS The LS water chiller range has been designed for small and medium residential and commercial applications. They are suitable for generating chilled water

More information

50TM TFF COMBINATION HEATING/COOLING UNITS

50TM TFF COMBINATION HEATING/COOLING UNITS 50T-1SB 50TM007-012 50TFF004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York

More information

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES Air to water chillers and heat pumps The water chillers range have been designed for small and medium residential and commercial applications. The water chillers are suitable for water outlet temperatures

More information

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating. capacity: Heating capacity: 20,8 to 135,1 kw 22,6 to 144,7 kw Scroll compressors R-410A refrigerant Confi guration fl exibility Silent operation DESCRIPTION The AirDuo cooling units and are units which

More information

NEXT DL NEXT DL. rcgroupairconditioning

NEXT DL NEXT DL. rcgroupairconditioning NEXT DL: Close control air conditioners with displacement air delivery with remote condenser, or built in water cooled condenser or for chilled water feeding Cooling capacity: 7,7 51,4 NEXT DL rcgroupairconditioning

More information

Roof top SPACE RPC 315Z R407C MA00

Roof top SPACE RPC 315Z R407C MA00 Client : TIHE SERV Contact : Romeo Staicu Your reference : Your contact : Phone : E-mail : Page : 1 / 6 Roof top SPACE RPC 315Z R407C MA00 Independant roof mounted unit, cooling only, ready to be installed,

More information

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning : Direct expansion close control air conditioners with up-flow or down-flow air delivery. Cooling Capacity: 7 102 NEW SOFTWARE R410A rcgroupairconditioning E C A C UP FLOW DOWN FLOW MAIN FEATURES Precision

More information

Concealed Ducted Split Series R-407C MBH

Concealed Ducted Split Series R-407C MBH Concealed Ducted Split Series R-407C 4-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION NOMENCLATURE UNIT RATING SUMMARY

More information

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB Next P 6 112 kw COOLING 5 93 kw HEATING Heat pump air conditioners with upflow air delivery technicalcatalogue T_NXTP_0411_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 4 MODEL IDENTIFICATION...

More information

Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60

Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60 Unit Dimension Unit Nomenclature DEHUMIDIFIER NOMENCLATURE R K D A - 0050 - C Z - M 4-8 UNIT VOLTAGE: 2: 240/1/60 5: 208-240/3/60 9: 480/3/60 8: 600/3/60 REFRIGEREANT R-404a MEDIUM TEMPERATURE SCROLL COMPRESSOR

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

Split Air Conditioners Cooled by air SOC076K to 240K-300L/ AHO-204FG to 1004FG SICH070/076B to 300B/ BCVI-204 to Technical information

Split Air Conditioners Cooled by air SOC076K to 240K-300L/ AHO-204FG to 1004FG SICH070/076B to 300B/ BCVI-204 to Technical information Split Air Conditioners Cooled by air SOC076K to 240K-300L/ AHO-204FG to 1004FG SICH070/076B to 300B/ BCVI-204 to 1004 Ref.: N-27493 0907 Technical information Johnson Controls Manufacturing España, S.L.

More information

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP EVH R-407C WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP Size Cooling Heating [kw] [kw] 7 2.0 1.9 11 2.6 2.5 15 3.9 3.3 5.2 5.5 25 7.3 6.7 31 8.9 8.4 41 10.7 9.8 REPLACE: BT02E009GB-01 The Versatemp

More information

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES Air to water chillers and heat pumps The water chillers range is an efficient and low-noise product designed for medium to big applications. The water chillers are suitable for water outlet temperatures

More information

Application guide Installation, operating and maintenance manual AIRCUBE - KSCM/KSHM. Providing indoor climate comfort

Application guide Installation, operating and maintenance manual AIRCUBE - KSCM/KSHM. Providing indoor climate comfort Application guide Installation, operating and maintenance manual AIRCUBE - Providing indoor climate comfort MIL84E-0607 07-2007 Congratulations you have made a wise choice and we feel sure that it will

More information

GUIDE SPECIFICATIONS AQUARIUS ii

GUIDE SPECIFICATIONS AQUARIUS ii Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Heat Pump, Ground Water

More information

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6 DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6 1.1. REFERENCE STANDARDS 1.2. GENERAL 1.1.1. The units shall be listed by Electrical Testing Laboratories (ETL) and bear the ETL label. 1.1.2.

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are

More information

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems Models: ACC 75D/DR ACC 100D/DR ACC - D2-2007 (Draft) Ceiling Concealed Split Systems CONTENTS 1. NOMENECLATURE... 2 2. FEATURES... 4 3. PRODUCT LINE UP... 5 4. SPECIFICATIONS... 8 5. OPERATING RANGE...

More information

EMI ENGINEERING SUBMITTAL

EMI ENGINEERING SUBMITTAL (MC2) MULTI-ZONE STRAIGHT COOL AIR CONDITIONING SYSTEMS Rev. 1.4 [4/05] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: UNIT

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units

york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units YORK YPRE RTR/RTP SERIES Air to air packaged rooftop units Cooling

More information

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: Y-R

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: Y-R Packaged air conditioning unit condensed by air model RTC 07L to 30L Ref.: Y-R70167 0707 Technical information I S O 9 0 0 1 ER-0028/1991 Johnson Controls Manufacturing España, S.L. is participating in

More information

50TM COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS 50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form

More information

LZA High efficiency air to water heat pumps with HP compressor

LZA High efficiency air to water heat pumps with HP compressor High efficiency air to water heat pumps with HP compressor -10 C +43 C +60 C HP C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT: GENERAL SPECIFICATIONS OUTDOOR UNIT: TECHNICAL GUIDE COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM MODELS HB 180 & HB 240 MODELS LB 180 & LB 240 15 & 20 NOMINAL TONS 9.7 EER Two independent refrigerant

More information

MAC-120HE-03 Air-Cooled Chiller

MAC-120HE-03 Air-Cooled Chiller MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03

More information

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual u Air-to-Water Reverse Cycle Heat Pumps AQH 40 to 130 40 to 131 kw 45 to 141 kw Engineering Data Manual EDM AQH-W.3GB Date : November 2007 Supersedes : TM AQH-W.2GB/03.04 Specifications The Aqu@Logic air-to-water

More information

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction Reducted footprint Dual-wall construction Built-in variable frequency drive PLC control Variable speed condenser fan Cooling capacity: 5 to 50 kw Air flow: 1 000 to 12 000 m 3 /h ErP READY Use Precision

More information

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator

More information

Modular Air Cooled Scroll Chillers

Modular Air Cooled Scroll Chillers Modular Air Cooled Scroll Chillers 65 80 130 Find out more at www.greeonline.com 160 249 High Efficiency Shell and Tube Heat Exchanger The Gree D Series Chillers utilise high efficiency shell and tube

More information