INDUSTRIAL USES OFFICE BUILDINGS APARTMENT HOUSES

Size: px
Start display at page:

Download "INDUSTRIAL USES OFFICE BUILDINGS APARTMENT HOUSES"

Transcription

1 -an ngersoll-rand Producf NDUSTRAL USES OFFCE BULDNGS APARTMENT HOUSES DEPARTMENT STORES SCHOOL BULDNGS ESTATES AND CLUBS

2 MOTORPUMP CONDENSATE RETURN UNTS THOROUGHLY DEPENDABLE _--=E~T~RE~L~Y- SELF- CONTANED_~. Absolute reliability is insured by the use of the Cameron MOTOR PUMP. n addition, complete standby equipment may be secured by the use of dual units whose duplicate pumps and motors are equipped with individual sylphon-operated starters. Compactness in the pump itself, together with tank mounting, saves time and effort during installation. No special foundation is required. St rdv C s Strong, pressure-tested copper-bearing steel tanks or 30-gallon cast iron reservoirs are furnished. Short piping connections afford additional rigidity. v Conservative rating of these units gives each pump a large reserve capacity to handle abnormal condensation in starting up cold systems and to return the condensate against varying boiler pressures. r Units are available with either one or two pumps. Standard tanks are of 15-, 30-, and 60-gallon capacities for ratings up to 30,000 square feet of equivalent direct radiation. Tanks are proportionately larger on units of greater capacity. Quick shipment from the factory can be made on all standard units. ngersoll-rand's experience in supplying the many special units required for industrial and unusual condensate problems assures prompt delivery of these made-to-order units. MOTORPUMP

3 MOTORPUMP condensate re turn unit on 15-~allon receiver with RVF% MOTORPUMP. This unit will handle as high as 5,000 square feet of direct radiation discharging against a pressure of 25 pounds per square inch. MOTORPUMP condensate return unit equipped with an RV2 MOTORPUMP on a 30-gallon cast iron receiver. Such a unit will handle as high as 15,000 square feet of direct radiation against pressures up to 50 pounds per square inch. MOTORPUMP condensate return unit equipped with two 1 RV2 MOTORPUMPS on a 60-gallon rece iver. Duplication of the MOTORPUMP insures continued service and provides additional reserve capacity to meet extraordinary demands.

4 FQR.SPECA L SERVC E -----~ MOTORPUMP Condensate Return Unit with 150 gallon horizontal tank and using a 2RV-5 MO TORPUMP. MOTORPUMP Condensate Return Units for large capacities or unusual conditions can be furnished. Explosion-proof motors and special controls are often necessary for Condensate Return Units used in connection with industrial processes and where other conditions require such precautions. Tanks of 200 gallon capacity and larger can be supplied and special tank shapes and mountings can be furnished to meet unusual co nditions. Five units ready for shipment to a large chemical company for replacing steam traps. Each is equipped with an explosion-proof motor and Mercoid switch. These were shipped on a repeat order, following units sold previously to the same concern. PUMP

5 NSTALLATON RELABLE boiler feeding in lowpressure steam heating systems is assured by the use of the MOTORPUMP Condensate Return Unit. Since condensate piping commonly follows a basement wall or partition, it is usually desirable to place the unit close to a wall, or in a corner, where it occupies little room. The compact construction of the MOTORPUMP Condensate Unit permits an ideal installation under such conditions. A single pump Condensate Return Unit with the steam heating system of a hotel in New York City. This is the smallest standard size of unit, using a 1 5 gallon tank. This MOTORPUMP Condensate Return Unit has been placed close to the central station type air conditioning unit of a New York department store. The Condensate Return Unit functions in the usual way in conjunction with the steam boiler of the system. THESE units are more efficient than steam traps for returning condensate. This has led to a number of replacement installations that are saving their owners many dollars in heating costs. MOTORPUMP Condensate Return Units are easy to install. t is necessary only to set the unit in place, connect the piping (intake and discharge connections are standard fittings), and wire it to an electric supply.

6 ~ SPECFCATONS When ordering the MOTORPUMP Condensate Return Unit give the following information: A. Total number of square feet of radiation and quantity of condensate in gallons per minute. B. Maximum and average operating pressure of boilers being served. C. Distance from center line of pump suction to water level in boiler; also size and length of discharge piping. D. Kind of current available. (1) direct current-show voltage. (2) alternating current-show voltage, phase and cycle. E. Specify single or dual pumping equipment. For Architects Furnish for location indicated on plan, a size.... Cameron MOTORPUMP Condensate Return Unit for... square feet of direct radiation or with a capacity of.... g.p.m. against a maximum boiler pressure of.... lbs. plus pipe friction and static lift between the water level in receiver and the boiler. The " built-in" electric motor(s) to be... hp... volts (A.C.-D.C.)... cycles... phase, capable of giving continuous operation without overloading. The pump(s) shall consist of single-stage, single-suction, bronze-fitted centrifugal MOTORPUMP(S) with enclosed impeller. Motor rotor and pump impeller are to be mounted on a common shaft. The pump casing shall be a separate high-grade iron casting with integral discharge nozzle, the shaft to be made of heat-treated, open-hearth steel, and is to be of large diameter to insure rigidity. The impeller will be of single-suction, enclosed type, cast of bronze in one piece. The rotor shall be supported by two sets of large ball bearings. One set is to be designed to carry any thrust loads that may be developed. The receiver shall be provided with suitable pipe openings for return pipe, vent connections and gauge glass. t shall be furnished with pads for bolting the MOTORPUMP(S) directly on the receiver, thereby eliminating baseplate. The control shall consist of a float and enclosed float switch mounted on the side of the receiver with suitabie means of sealing to withstand a pressure of 20 pounds per square inch. t shall be adjusted to start the pump when receiver is full, and stop it when receiver has been emptied. - 0

7 DMENSONS 15 Gal. Tank- Single Pump Unit 30 Gal. Cast ron Tank-Single Pump Unit 30 Gal. Tank- Two Pump Unit 60 Gal. Tank- Single Pump Unit p

8 DATA ON MOTOtPUMP CONDENSATE RETURN UNTS One pump unit Two pump un it Maximum Pump Capacity Ouantity Diameter Direct discharge Size and o f each of con- Siz e of of con- Ship- Shipradi ation pressure M otor h.p. pump densa te reserv oir densate Floor ping Floor ping sq. ft. lbs. sq. in. * g. p. m. g. p. m. gals. inlet space weight space weight ins. ins. lbs. ins. lbs , RVF % X !;2 X 33V , RVFY4 4V2 1 Y X V2 X 33V , RVF14 1V2 2y X V2 X 33V , RVFV X X , RVFV2 21 1Y X X , RVF% x 40 V X , RVF% 36 12!; X 40 V X , RVF% X 40 V X , RVF V2 214 % X /2 X 33V , RVF V2 4V2 1 Y X V2 X 33V , RVF V2 1y2 2y X !;2 X 33V , RVFV X X , RVFV2 21 1V X X , RVF% X 40!; X , RVF% 36 12!; X 40V X , RVF% X 40V X , RVF% 2 14 % X V2 X 33V , RVF% 4Y2 1 Y X V2 X 33 V , RVF% 1V2 2 y X V2 X 33V , RVF% X X , RVF% 21 1V X X , RVF% X 40!; X , RVF !; X 40V X , RVF X 40V X , RVF% 214 % X !;2 X 33!; , RVF% 4V2 1 Y X Y2 X 33V , RVF% 1y2 2y X V2 X 33V , RVF X 30V V2x , RVF1 21 1V X 30V V2x , RVF x40V X , RVF V X 40V X , RV1 Y x41V X 54!; , RV X V2 X 44V , RV2 21 1V X V2 X 44V , RV X 41 Y2 510 X 54!; , RV V X 4 1V X 54Y , RV X 41 V X 54V2 700 *Example-(lRVFj:) : First fi gure (1) is diameter of pump discha rge in inches; le tters (R VF) are pump symbol ; last fi g ur e (;) is horsepower of motor. Unit s fo r Larger Capacilies and Higher H eads are available. Refer to nearest -R Dra nch. NGERSOLL-RAND COMPANY, 11 BROADWAY, NEW YORK CTY BRMNGHAM BOSTON BUFFALO BUTTE London Paris CHCAGO CLEVELAND DALLAS DENVER Madrid H!vlm 3 DETROT DULUTH EL PASO HOUSTON KNOXVLLE LOS ANGELES NEWARK NEW YORK PHLADELPHA PCHER Branches or distributors in principal cities the world over. Vienna Johannesburg Calcutta Tokyo Valp3raiso Rio de Janeiro Soo Paulo PTTSBURGH SALT LAKE CTY SAN FRANCSCO SCRANTON Lima Brussels Santiago Bombay SEATTLE ST. LOUS TULSA WASHNGTON Buenos Aires Stockholm FORM 1972-A fll 5 M 1-6

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation. Brochure# 228E 122011 TYPE VSA SEWAGE PUMP Capacities to 100 gpm, Heads to 120, Horsepower range 3/ thru 0, 3 thru discharge, 1750 and 1150 operation. HIGHLIGHTS Wet-Pit Installations Pumps Suspend From

More information

5. CONDENSATE PUMPS/UNITS

5. CONDENSATE PUMPS/UNITS INDEX Condensate Systems/Pumps GENERAL INFORMATION BURKS PARTS I&O MANUALS. CONDENSATE PUMPS/UNITS PUMP TYPES: GV GV6 USA: (937) 778-8947 Canada: (90) 47-6223 International: (937) 61-398 A 7/1 Condensate

More information

Condensate Boiler Feed Water Make-Up

Condensate Boiler Feed Water Make-Up 1144 Utica Ave, Brooklyn, NY 1103 July 0 New Catalogue Release Bulletin 9C.01 Low Inlet Condensate Receiver (7 from floor) Close Grained Cast Iron Simplex and Duplex Design To 0,000 SQ-Ft EDR Pump Capacity

More information

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI Vent-Rite BULLETIN VCRV AUGUST 0 GUARDIAN Plus Cast Iron And Steel Receivers Simplex, Duplex, Triplex And Quadruplex Units Pump Capacities To 0 GPM Discharge Pressure To 7 PSI 87 Dewey Avenue Benton Harbor,

More information

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features Electric Pumps Introduction W4100, W4200 & W4300 Condensate Pumps Watson McDaniel s Condensate Return and Boiler Feed Pumps are equipped with Cast Iron bodies and Bronze Impellers. The pump receiver tanks

More information

4600 SERIES. Technical Specifications. Condensate Units - Steel Tank. Features

4600 SERIES. Technical Specifications. Condensate Units - Steel Tank. Features Steam Traps Condensate oiler Feed Valves Strainers Pumps 0 SERIES Condensate Units - Steel Tank Technical Specifications Sterlco 0 Series Condensate Units set new standards of performance. Reliable and

More information

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features Steam Traps Condensate Boiler Feed Valves Strainers Pumps J SERIES Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps Technical Specifications The Sterlco J Series Centrifugal Pumps are designed

More information

MARLOW PUMPS RECIRCULATION

MARLOW PUMPS RECIRCULATION End suction centrifugal pump line available in both close coupled and frame mounted configurations allow users to meet exactly most flow conditions on commercial pool and waterpark applications. Features

More information

SECTION STEAM CONDENSATE PUMPS

SECTION STEAM CONDENSATE PUMPS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 22 23 STEAM CONDENSATE PUMPS SPEC WRITER NOTES: 1. Delete between // ---- // if not applicable to project. Also delete any other item or paragraph not applicable

More information

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Domestic Pump Series VCMD TM Combination Vacuum & Boiler Feed Unit

Domestic Pump Series VCMD TM Combination Vacuum & Boiler Feed Unit Custom engineered units to maintain optimum boiler levels and system vacuum requirements Four styles to choose from to minimize floor space requirements Multi-jet vacuum pumps for quiet, dependable and

More information

Condensate Return Feedwater Systems For Low and High Pressure Steam Boilers

Condensate Return Feedwater Systems For Low and High Pressure Steam Boilers For Low and High Pressure Steam Boilers Rite s feedwater return systems are engineered for the safe and efficient storage and pumping of condensate and make-up water back to the boiler. Why Rite? Because

More information

FEATURES. Other Fed-Flush Arrangements

FEATURES. Other Fed-Flush Arrangements Brochure # 0710 TYPE TYPE... VSAF SEWAGE EJECTOR SYSTEM Flows to 600 gpm, Heads to 120, 1 thru 40 HP. Discharge size 4, 1750 and 1150 RPM, strainer in discharge pipe. HIGHLIGHTS Installations where rags

More information

FLANGE-MOUNT CENTRIFUGAL PUMPS

FLANGE-MOUNT CENTRIFUGAL PUMPS 40 Third Street Piqua, Ohio 4556-060 www.pumpagents.com PumpAgents.com - Click here for Pricing/Ordering SERIES GV6 SECTION E PAGE ISSUED /0 REPLACES /0 FLANGE-MOUNT CENTRIFUGAL PUMPS Idel for OEM applications

More information

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI Hydraulic Institute Standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE. Temperature Control Units Water & Oil 0-00 F Portable Chillers 0 - F Central Chillers Packages & Modules 0 - F Pump Tank Stations Chilled or Tower Water 00-0 gallons Cooling Tower Cells 4-40 tons Filters

More information

Stainless Steel Condensate Return Units

Stainless Steel Condensate Return Units Stainless Steel Condensate Return Units Pressurized and Atmospheric Deaerators HIGH QUALITY STAINLESS STEEL EXCEPTIONAL VALUE, EXTRAORDINARY QUALITY industrialsteam.com Stainless Steel Condensate Return

More information

INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. Condensate Return Systems General Installation, Operation, & Service Instructions !

INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. Condensate Return Systems General Installation, Operation, & Service Instructions ! Condensate Return Systems General Installation, Operation, & Service Instructions INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. SAFETY INSTRUCTIONS This safety alert symbol will be used in this

More information

Domestic Pump Condensate Transfer Equipment

Domestic Pump Condensate Transfer Equipment Bulletin S-944L Domestic Pump Condensate Transfer Equipment CONDENSATE RETURN UNITS BOILER FEED UNITS LOW NPSH PUMPS VACUUM HEATING UNITS INDUSTRIAL VACUUM UNITS www.domesticpump.com Condensate Return

More information

Hoffman Specialty Pump Products

Hoffman Specialty Pump Products Condensate Units Boiler Feed Units Vacuum Heating Units Hoffman Specialty Pump Products S-0692C INDEX Condensate Return Units Series WC Series WCS Series SCC Boiler Feed Units Stock Watchman Condensate

More information

Dean Pump High Temperature Chemical Process Inline Pumps

Dean Pump High Temperature Chemical Process Inline Pumps Bulletin C-1.2.21. Dean Pump High Temperature Chemical Process Inline Pumps Series DL Dean Pump Series DL High Temperature Chemical Process Inline Pumps Capacities to 600 GPM (182 m 3 /hr) Heads to 0 feet

More information

SECTION AIR COMPRESSORS AND ACCESSORIES

SECTION AIR COMPRESSORS AND ACCESSORIES PART 1 GENERAL 1.01 WORK INCLUDED SECTION 11370 AIR COMPRESSORS AND ACCESSORIES A. This specification includes air compressors with air dryers. B. Furnish, install, start-up, and test air compressors and

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards Date Description of Change Pages / Sections Modified ID 6/15/16 Entire document - mgl44 PART 1 - INTRODUCTION 1.1 PURPOSE A. This section is intended to define the general installation and minimum product

More information

DualPak Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Sept. 28, DualPak 6900 Series Booster System

DualPak Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Sept. 28, DualPak 6900 Series Booster System DualPak Series 6900 FILE NO: 62.11 DATE: Feb. 15, 1999 SUPERSEDES: 62.11 DATE: Sept. 28, 1995 DualPak 6900 Series Booster System D U A L P A K 6 9 0 0 Armstrong proudly presents the Series 6900 DualPak

More information

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP DS series Industrial End Suction Pumps ISO/DP 5199 www.sterlingpumps.com.au DS series Capacities from: Heads from: 340 to 5,680 m3/h (1,500 to 25,000 USPGM) 21 to 106 metres (70 to 350 feet) Power range

More information

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes. Introduction to Hydronics A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes. Hydronic heating systems use hot water or steam to deliver the

More information

Horizontal Split Case Pumps Type U

Horizontal Split Case Pumps Type U Horizontal Split Case Pumps Type U 7.1 7.2 Stage U Type Pumps Features: Axially Split Case Design Range from 20M 3 /Hr to 600M 3 /Hr Two Stage Pump Single Suction Twin Volute Casing Design Closed type

More information

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016 SECTION 23 21 23 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions and Division 01 Specification Sections, apply to this Section.

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS PART 0 A/E INSTRUCTIONS 0.01 Design Requirements A. Pumping system design 1. A primary-secondary pumping system is preferred. Redundant pipes are required for chillers and boilers. 2. Select pumps to operate

More information

MODEL P. 2 ft. NPSH Cast Iron Bronze Fitted Low NPSH Centrifugal Pumps. BULLETIN 112 Revised 7/09. PH (Horizontal Flange Mounted)

MODEL P. 2 ft. NPSH Cast Iron Bronze Fitted Low NPSH Centrifugal Pumps. BULLETIN 112 Revised 7/09. PH (Horizontal Flange Mounted) SHIPPENSBURG PUMP CO., INC. P.O. BOX 279, SHIPPENSBURG, PA 17257 PHONE 717-532-7321 FAX 717-532-7704 WWW.SHIPCOPUMPS.COM BULLETIN 112 Revised 7/09 PH (Horizontal Flange Mounted) MODEL P 2 ft. NPSH Cast

More information

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models) Temperature Control Units Water & Oil - 00 F Portable Chillers Air & Water-Cooled 0-70 F Central Chillers Air & Water-Cooled Packages & Modules 0-70 F Pump Tank Stations Chilled or Tower Water 00-00 gallons

More information

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage. LN series Horizontal Split Case Pumps Double Volute. Single Stage www.sterlingpumps.com.au LN series Sizes: 6 to 42 Capacity to 12,500 m³/h Heads to 190 metres A rugged, single stage, double volute horizontal

More information

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 Building Services Piping. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections. SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15410 - Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections. 1.02 SUBMITTALS A. Submit properly identified

More information

Full-line Product Overview

Full-line Product Overview Full-line Product Overview End Suction Centrifugal Pumps This general purpose pump can be configured in frame-mounted and close-coupled, semi-open and enclosed impeller configurations. They are available

More information

PUMPS & PUMPING SYSTEMS FOR THE CHEMICAL PROCESSING & HEATING & AIR CONDITIONING INDUSTRY

PUMPS & PUMPING SYSTEMS FOR THE CHEMICAL PROCESSING & HEATING & AIR CONDITIONING INDUSTRY PUMPS & PUMPING SYSTEMS FOR THE CHEMICAL PROCESSING & HEATING & AIR CONDITIONING INDUSTRY THE ROTH SOLUTION PROVIDES: Lowest NPSHr - Lower Motor Speeds Lower Tank Heights - Reduced Maintenance ROTH PUMP

More information

SECTION STEAM CONDENSATE PUMPS

SECTION STEAM CONDENSATE PUMPS SECTION 23 22 23 STEAM CONDENSATE PUMPS PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable in the

More information

PIONEERS IN AIR VACUUMS

PIONEERS IN AIR VACUUMS PIONEERS IN AIR VACUUMS SINCE 1947 Rema Dri-Vac Corp. 45 Ruby Street Norwalk, CT 06850 Phone: 203-847-2464 Fax: 203-847-3609 Email: info@remadrivac.com WWW.REMADRIVAC.COM AIR VACUUMS RETURN SYSTEMS BURK

More information

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps Note: The A/E must choose all design values in brackets below before using in project specifications 1 General 1.1 Provide UL listed and FM approved fire pump complete with pump, driver, controller and

More information

BuildingName The Description of the Project P DOCUMENTS

BuildingName The Description of the Project P DOCUMENTS ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION

More information

1.1 This section applies to air handling units for HVAC Systems.

1.1 This section applies to air handling units for HVAC Systems. AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling

More information

mith Mills 3500A Smith Mills 3500A 3500A-3 OIL, GAS OR COMBINATION GAS/LIGHT OIL COMMERCIAL BOILER/BURNER CAST IRON

mith Mills 3500A Smith Mills 3500A 3500A-3 OIL, GAS OR COMBINATION GAS/LIGHT OIL COMMERCIAL BOILER/BURNER CAST IRON Mills 300A mith Mills 300A Smith CAST IRON 300A3 OIL, GAS OR COMBINATION GAS/LIGHT OIL COMMERCIAL BOILER/BURNER COMBUSTION CHAMBER DETAILS SIDE VIEW GAS FIRED FRONT VIEW WATER SIDE VIEW NATURAL DRAFT WATER

More information

SENTRA Series Water Unit

SENTRA Series Water Unit SENTRA Series Water Unit Standard Unit: F to 0 F Process Fluid Temperatures* Optional High Temperature Configuration to 0 F Direct Injection Cooling 0 to kw Heaters to 7. HP Centrifugal Pumps (0-00 GPM)

More information

SECTION PUMPS. 6. Section Steam and Condensate Piping and Specialties.

SECTION PUMPS. 6. Section Steam and Condensate Piping and Specialties. SECTION 15540 PUMPS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Base Mounted Pumps. 2. Horizontal Split Case Pumps. 3. In line Pumps. 4. Steam Condensate Return Pumps. B. Related Sections: 1. Section

More information

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y N N O V A T I O N E F F I C I E N C Y Q U A L I T Y Standard Pumps Manufacturing Plants Today Ruhrpumpen is a worldwide company, with a network of global manufacturing plants in different countries and

More information

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems. Issued 2006/08/01 Section 15131 Pumps Hydronic Systems Page 1 of 6 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal.3 Section 01780

More information

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013 SECTION 15800 - AIR HANDLING EQUIPMENT 1.1 GENERAL A. All air handlers installed shall conform to the University of Rochester specification Guideline for Semi-Custom and Pre-Engineered Air Handling Units.

More information

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS MODEL 652A MODEL 654A MODEL 652A MODEL 651A MODEL 653A AURORA 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS WWW.AURORAPUMP.COM 2 AURORA 650 Series Single Stage Solids Handling Pumps Capacities to 2000

More information

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES P R O D U C T S P E C I F I C AT I O N S W A T E R H E A T E R S / B O I L E R S CONSERVATOR Gas-Fired Steam Boiler Bulletin No. 20263 October 200 Supersedes September 2008 AFUE up to 82.7% Heating Input

More information

Goulds 3600 Between-Bearing, Axially-Split, Multi-Stage Pumps. Goulds Pumps

Goulds 3600 Between-Bearing, Axially-Split, Multi-Stage Pumps. Goulds Pumps Between-Bearing, Axially-Split, Multi-Stage Pumps Goulds Pumps A Leader in API Engineered Pump Package Solutions Proven API Leadership ITT Goulds Pumps is a proven leader in API Pumps Over 18,000 units

More information

Pumps SELECTION OF A PUMP

Pumps SELECTION OF A PUMP Pumps SELECTION OF A PUMP A water system needs to move the water produced from the source to its customers. In almost all cases in Minnesota, the source is at a lower elevation than the user so the water

More information

/ / Take the technological step into MODERN Condensate Handling Equipment for steam systems MANUFACTURED IN AMERICA with craftsmanship and quality.

/ / Take the technological step into MODERN Condensate Handling Equipment for steam systems MANUFACTURED IN AMERICA with craftsmanship and quality. Take the technological step into MODERN Condensate Handling Equipment for steam systems MANUFACTURED IN AMERICA with craftsmanship and quality. Condensate Return Units / Shippensburg / / Fill Tanks / Boiler

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

Model T Professional Series 3/4HP 2 YEAR WARRANTY SEWAGE PUMP

Model T Professional Series 3/4HP 2 YEAR WARRANTY SEWAGE PUMP Model T00405 REPAIR PARTS REF. PART DESCRIPTION REF. PART DESCRIPTION 1 450331 Strainer 2 450332 Oil cover "O" ring 3 400447 Impeller 4 450333 Pump casing 5 400450 Oil cover 6 400449 Oil seal 7 400448

More information

Domestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR.

Domestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR. Cast Iron Receivers: For years of dependable service; warranted for 20 years from date of shipment against failure due to corrosion. Each Receiver comes standard with Inlet connection, an overflow and

More information

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps... PUMPS FOR INDUSTRY CONTENTS: The Vertical Pump Specialists Introduction & User List Product Overview Vertical Process Pumps... Series 600 Vertical Sewage Pumps... Series 700 Vertical Sump Pumps... Series

More information

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant. SECTION 218800 - FIRE PROTECTION 1. GENERAL A. Provisions of Division 1, GENERAL REQUIREMENTS, and Section 230000, MECHANICAL GENERAL CONDITIONS, and Section 230050, SEISMIC PROTECTION are a part of this

More information

DUPLEX CONDENSATE TANK SYSTEM

DUPLEX CONDENSATE TANK SYSTEM DUPLEX CONDENSATE TANK SYSTEM PROJECT NAME: 7 EAST 54TH STREET CONTRACTOR: PRO PUMP CORP ENGINEER: KEVAN WOODWORTH SUBMITTED BY: NISSIM ISAACSON DATE: 2.20.205 DESIGN DATA Model GPM TDH HP Volt Phase RPM

More information

Deaerator. Specifications

Deaerator. Specifications ESI, INC. OF TENNESSEE RENTAL EQUIPMENT Deaerator Description The deaerator, built in 1996, is a spray-type deaerating feedwater heater and storage tank with stainless steel internals. The deaerator is

More information

Type VSA Suspended Wet Pit Sewage Pumps BULLETIN 228E-1 September 2014

Type VSA Suspended Wet Pit Sewage Pumps BULLETIN 228E-1 September 2014 Wet Pit Installations Pumps suspended from pit or basin cover. Up to 3 Solids Handling 1750 and 1150 RPM Selections. Fiberglass and steel basins available. Steel covers and grouting frames for concrete

More information

Goulds 3600 Between-Bearing, Axially-Split, Multistage Pumps

Goulds 3600 Between-Bearing, Axially-Split, Multistage Pumps Goulds Pumps Goulds 3600 Between-Bearing, Axially-Split, Multistage Pumps motralec 4 rue Lavoisier. ZA Lavoisier. 95223 HERBLAY CEDEX Tel. : 01.39.97.65.10 / Fax. : 01.39.97.68.48 Demande de prix / e-mail

More information

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS SECTION 22 20 00 LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements",

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

380 Series Multi-Stage Centrifugal Pumps

380 Series Multi-Stage Centrifugal Pumps 380 Series Multi-Stage Centrifugal Pumps Flows to: 4,800 GPM Heads to: 2100 Feet Temperatures to: 500 F TDH - Feet 130 Years of Pump Manufacturing American-Marsh Pumps, one of the oldest pump lines in

More information

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST Item # Quantity C.S.I. Section 11400 DISHWASHER STANDARD FEATURES 244 racks per hour Opti-RinSe system Ball detent clutch conveyor drive mechanism Top mounted controls Stainless steel anti-clogging wash

More information

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED FUEL OIL DAY TANKS SST Series - Engineering Submittal SST Series - Advanced Line Day Tanks Construction: UL 142 aboveground steel tank all seam welded, square, atmospheric tank of heavy gauge steel with

More information

SECTION PLUMBING EQUIPMENT

SECTION PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Water heaters B. Packaged water heating systems C. Water storage tanks D. Water softeners E. Pumps F. Circulators 1.2 REFERENCES SECTION 22 30 00 PLUMBING EQUIPMENT

More information

SECTION STEAM CONDENSATE PUMPS

SECTION STEAM CONDENSATE PUMPS SECTION 23 22 23 - STEAM CONDENSATE PUMPS PART I - GENERAL 1.1 SECTION INCLUDES A. Steam Condensate Return Units, Gravity Return Type 1. Receiver 2. Pumps 3. Control Panel 4. Accessories Note to PSC: Although

More information

Family Curve. Submersible Grinder Pumps 1¼" and 2" Discharge. Effluent/Grinder Pumps.

Family Curve. Submersible Grinder Pumps 1¼ and 2 Discharge. Effluent/Grinder Pumps. Family Curve Submersible Grinder Pumps 1¼" and 2" Discharge 7 11/0 Submersible Vortex Grinder Pumps SGV, 2HP, Double Seal, Oil-Filled Word File FILE: SPEC4 SCOPE: Furnish and install submersible grinder

More information

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM The GH Series The GH is Carver s horizontal, end suction pump series for handling water, oils, and chemicals in marine, process, and general

More information

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y SMF. Vertical Submersible Pump

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y SMF. Vertical Submersible Pump N N O V A T I O N E F F I C I E N C Y Q U A L I T Y SMF Engineering Excellence More Than 60 Years Developing The Pumping Technology That Drives Progress Ruhrpumpen is an innovative and efficient pump technology

More information

1900 Series In-Line Pump

1900 Series In-Line Pump Water Circulation Pumps & Circulators 1900 Series In-Line Pump HYDRONIC COMPONENTS & SYSTEMS Taco Catalog #: 300-1.4 Supersedes: 300-1.4 Dated: 06/15/95 Effective Date: 03/15/05 Printed in USA 2. Features

More information

Ruhrpumpen Fire Systems

Ruhrpumpen Fire Systems FIRE SYSTEMS RP FIRE SYSTEMS Ruhrpumpen Fire Systems Fire pumps play a vital role as the first response to a fire situation, saving countless lives and property from destruction. They are usually found

More information

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump GH End-Suction Centrifugal Pump GH Horizontal end-suction pump for handling water, oils and chemicals in marine, process and general industrial applications. Hydraulic performance extends to 2,500 GPM

More information

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump GH End-Suction Centrifugal Pump GH Horizontal end-suction pump for handling water, oils and chemicals in marine, process and general industrial applications. Hydraulic performance extends to 2,500 GPM

More information

EBARA. Submersible Non-clog Pump Model DLFU Model DVFU Model DDLFU

EBARA. Submersible Non-clog Pump Model DLFU Model DVFU Model DDLFU EBARA Submersible Non-clog Pump Model DLFU Model DVFU Model DDLFU water wastewater EBARA International Corporation Standard Pump Division S ubmersible Non-clog Pump Model DLFU DVFU DDLFU Features Watertight

More information

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E WATER HEATERS / BOILERS -E PRODUCT SPECIFICATIONS Gas-Fired Steam Boiler Bulletin No. 20653 September 202 Supersedes Bulletin No. 20263 AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh MODEL NUMBER

More information

TECHNICAL. Series 18. Pump Packages

TECHNICAL. Series 18. Pump Packages TECHNICAL S Y S T E M S Series 18 Pump Packages Series 18 Pump Packages Standard Features Close-coupled, end-suction, centrifugal pumps Mounted and wired pump starters Hand-Off-Auto switch for each pump

More information

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers. SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

GIRTON CABINET WASHER MODEL 794A

GIRTON CABINET WASHER MODEL 794A DESCRIPTION GIRTON CABINET WASHER MODEL 794A The washer shall be a Girton Model 794A Cabinet Type Pressure Washer constructed of type-304 stainless steel, utilizing a reciprocating header spray system.

More information

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet 3020/3120 Series Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet A Crane Co. Company DEMING PUMPS Introducting Deming 3020/3120 Series End-Suction

More information

MODEL 664A MODEL 662A MODEL 663A MODEL 661A AURORA. 660 Series SINGLE STAGE SOLIDS HANDLING VORTEX PUMPS

MODEL 664A MODEL 662A MODEL 663A MODEL 661A AURORA. 660 Series SINGLE STAGE SOLIDS HANDLING VORTEX PUMPS MODEL 662A MODEL 664A MODEL 661A MODEL 663A AURORA 660 Series SINGLE STAGE SOLIDS HANDLING VORTEX PUMPS WWW.AURORAPUMP.COM 2 AURORA 660 Series Single Stage Solids Handling Vortex Pumps Capacities to 2600

More information

CLOSED COUPLED CENTRIFUGAL PUMPS

CLOSED COUPLED CENTRIFUGAL PUMPS 0 Third Street Piqua, Ohio 6-060 www.pumpagents.com PumpAgents.com - Click here for Pricing/Ordering SERIES G--/ G6--/ SECTION B PAGE ISSUED /0 REPLACES /0 CLOSED COUPLED CENTRIFUGAL PUMPS 00RPM - 60Hz.

More information

C44A/C44AW DISHWASHER

C44A/C44AW DISHWASHER Item # Quantity C.S.I. Section 11400 C44A/C44AW DISHWASHER STANDARD FEATURES 202 racks per hour C44A 126 racks per hour C44AW Opti-RinSe system Ball detent clutch conveyor drive mechanism Top mounted controls

More information

SECTION FIRE PUMP AND CONTROLS

SECTION FIRE PUMP AND CONTROLS SECTION 15320 FIRE PUMP AND CONTROLS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Fire pump, jockey pump, and controls including necessary accessories as shown in Construction Documents, specified

More information

The Replacement Motor & Fan Specialists

The Replacement Motor & Fan Specialists The Replacement Motor & Fan Specialists Residential Commercial Electric Motors Fans & Blowers Hydronic Pumps Accessories www.soperssupply.com Industrial Soper s Supply Ltd. Proud Distributor of the Following

More information

SECTION AIR HANDLING UNIT

SECTION AIR HANDLING UNIT SECTION 15800 - AIR HANDLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR

More information

Worthington D-1100 vertical in-line pumps

Worthington D-1100 vertical in-line pumps New CENTRIFUGAL PUMPS 2014-4 Page 1 FEATURES D-1100 Worthington D-1100 vertical in-line pumps Sizes 1 to 60 hp, 800 gpm, 600 ft. 20E-20253 A standard in-line pump offering advanced design features for

More information

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

4VH and 4VHX. 4 Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction 4VH and 4VHX 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction DURABLE MOTOR WILL DELIVER MANY YEARS OF RELIABLE SERVICE Oil-filled motor for maximum heat dissipation

More information

G315/6 Cast Iron Boiler

G315/6 Cast Iron Boiler Engineering Submittal Sheet Boiler Overview LISTED Engineering Specifications There shall be provided and installed G315-6 Buderus sectional cast iron hot water boiler(s), suitable for forced draft firing

More information

SECTION AIR COMPRESSORS AND ACCESSORIES

SECTION AIR COMPRESSORS AND ACCESSORIES PART 1 GENERAL 1.01 WORK INCLUDED SECTION 11370 AIR COMPRESSORS AND ACCESSORIES A. This specification includes air compressors with air dryers. B. Furnish, install, start-up, and test air compressors and

More information

AFUE 95% Heating Input 50,000 to 200,000 Btuh

AFUE 95% Heating Input 50,000 to 200,000 Btuh PRODUCT SPECIFICATIONS WATER HEATERS / BOILERS GWM-IE Gas-Fired, Modulating, Condensing, Wall Hung Hot Water Boiler Bulletin No. 210650 March 2018 Supersedes December 2015 AFUE 95% Heating Input 50,000

More information

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Product Family Overview

Product Family Overview Condensate Boiler Feed Pumps Steam Traps Valves Strainers Temperature Control Process Cooling Material Handling Size Reduction Product Family Overview Precision Engineered. Fully Integrated. Expertly Supported.

More information

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW INSTALLATION INSTRUCTIONS RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW 92-106595-01-00 TABLE OF CONTENTS Introduction.......................................

More information

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime.

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime. Armstrong Mini Pump Bulletin AFH-223 The Armstrong mini pump trap is the smallest non-electric solution that can move condensate or other liuids from lower to higher points and from lower to higher pressures.

More information

USERS INFORMATION MANUAL FOR GAS FIRED BOILERS

USERS INFORMATION MANUAL FOR GAS FIRED BOILERS USERS INFORMATION MANUAL FOR GAS FIRED BOILERS CATALOG NO.: 2000.52G Effective: 06-01-00 Replaces: 07-01-94 WARNING: If the information in this manual is not followed exactly, a fire or explosion may result

More information

Copy Right By: Thomas T.S. Wan

Copy Right By: Thomas T.S. Wan Chapter 23 Motor and Starter Copy Right By: Thomas T.S. Wan 温到祥著 Sept. 3, 2008 All rights reserved Electric Motors All the motors are to be designed and constructed in accordance with NEMA code. Electric

More information

.03 ATMOSPHERIC DEAERATOR

.03 ATMOSPHERIC DEAERATOR .03 ATMOSPHERIC DEAERATOR SPECIFICATION SHEET NO. 3200 OCTOBER 1, 2007 GENERAL DESCRIPTION The Sellers atmospheric.03 deaerators condition make-up water and condensate returns to convert them into more

More information

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Design and Construction Standards SECTION PLUMBING EQUIPMENT SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES: A. Water heaters. B. Packaged water heating systems. C. Water storage tanks. D. Water softeners. E. Pumps. F. Circulators. 1.2 REFERENCES

More information