The Best In Machine Guarding Interlock Options

Size: px
Start display at page:

Download "The Best In Machine Guarding Interlock Options"

Transcription

1 The Best In Machine Guarding Interlock Options

2 Option 1: THESSQ1 locked the machine will operate. Operator can gain entry by pressing down the silver access handle and retracting the tongue from the safety gate switch which immediately isolates power to the machine and enables the guard door to be opened. After the door has been opened, lockout/tagout can be applied to the a metal flap at the back of the handle, preventing the tongue from being reinserted into the safety gate switch head, preventing restart of the machinery.

3 Option 2: THESNSSQ1 The key is removed and kept by the operator while working inside the guarded area. locked the machine will operate. Operator can gain entry by turning the key 90 clockwise which immediately isolates power to the machine and enables the silver access handle to be operated in order to open the guard door. After door has been opened, lockout/tagout can be applied to the a metal flap at the back of the handle. Machinery cannot be restarted while operator is inside the area. After work is completed, remove lockout/tagout, close and lock the door. Once the key is in run position the machinery can restart.

4 Option 3: THESSELQ5 locked the machine will operate. This switch utilises a solenoid which holds the guard door closed until the machine has finished its current operating cycle. The operator must request access by pressing a push button on a nearby machine control panel or the machine s HMI. This initiates the entry procedure and brings the machine to a controlled stop. Once the machine has finished its current operating cycle and the machine has entered a safe state of operation, a signal will be sent to energize the solenoid controlled safety gate switch illuminating the red LED on the body of the switch to notify the operator it is now safe to enter the machine. The operator presses down on access handle to gain entry. At this point. the silver access handle can now be pressed down to open the door and lockout/tagout can be applied. After the work is completed, remove lockout/tagout, close and lock the door.

5 Option 4: THESNSMELQ5 locked the machine will operate. This switch utilises a solenoid which holds the guard door closed until the machine has finished its current operating cycle. The operator must request access by pressing a push button on a nearby machine control panel or the machine s HMI. This initiates the entry procedure and brings the machine to a controlled stop. Once the machines has finished its current operating cycle and the machine has entered a safe state of operation, a signal will be sent to energize the solenoid controlled safety gate switch illuminating the red LED on the body of the switch to notify the operator it is now safe to enter the machine. The key is turned 90 clockwise, illuminating the Green LED on the body of the switch. This enables access by pressing down on handle to open the door. The key is removed and kept by the operator while working inside the guarded area. After the work is completed, remove lockout/tagout, close and lock the door. Once the key is in run position the machinery can restart.

Machine Guarding. 1 Copyright 2014, Rev by PEC Safety Management, Inc. PPT-SM-MG 2014, Rev

Machine Guarding. 1 Copyright 2014, Rev by PEC Safety Management, Inc. PPT-SM-MG 2014, Rev Machine Guarding 1 Copyright by PEC Safety Management, Inc. The Importance of Machine Guarding Amputations are among the most severe and disabling workplace injuries Amputations may result from improperly

More information

Gas Safety Products. Installation, operating and maintenance 28/10/2015. Merlin CT1250 Gas Interlock System. S&S Northern Ltd 1

Gas Safety Products. Installation, operating and maintenance 28/10/2015. Merlin CT1250 Gas Interlock System. S&S Northern Ltd 1 Gas Safety Products Merlin CT1250 Gas Interlock System Installation, operating and maintenance 28/10/2015 S&S Northern Ltd 1 Table of contents 1 General information... 3 2 Installation... 3 2.1 Panel Mounting.....

More information

Machine Safeguarding and Lockout/Tagout Practices

Machine Safeguarding and Lockout/Tagout Practices Manufacturing Machine Safeguarding and Lockout/Tagout Practices On a daily basis, manufacturing employees may be asked to work with or interact with a wide variety of machinery and equipment. Some machines

More information

Lock Out/Tag Out: Control of Hazardous Energy (LOTO) Environmental Health &Safety / Risk Management

Lock Out/Tag Out: Control of Hazardous Energy (LOTO) Environmental Health &Safety / Risk Management Lock Out/Tag Out: Control of Hazardous Energy (LOTO) Environmental Health &Safety / Risk Management 229-4503 LOTO "Lockout/Tagout (LOTO)" refers to specific practices and procedures to safeguard employees

More information

MANUFACTURING TECHNICAL INSTRUCTIONS - SAFETY REVIEW DATE: 10/29/2002

MANUFACTURING TECHNICAL INSTRUCTIONS - SAFETY REVIEW DATE: 10/29/2002 1 of 15 AUTOMATION SAFEGUARDING REQUIREMENTS FOR DESIGN, CONSTRUCTION, MANUFACTURING AND INSTALLATION OF AUTOMATED SYSTEMS I. SCOPE AND PURPOSE A. Scope To provide guidelines for Design, construction,

More information

Steel Applications. Electric Arc Furnace: Cranes (Blast Furnaces): Converter Maintenance Lift: Desulphurisation Pit: Rabbler: Ladle Furnace:

Steel Applications. Electric Arc Furnace: Cranes (Blast Furnaces): Converter Maintenance Lift: Desulphurisation Pit: Rabbler: Ladle Furnace: Steel pplications lectric rc Furnace: Cranes (Blast Furnaces): Converter Maintenance Lift: Desulphurisation Pit: abbler: Ladle Furnace: Continuous Casting Machine: Continuous Billet Caster: Cranes (Slab

More information

Machine and Power Tool Safety Checklist. Version 1.1 March Chestnut Street, Suite 400, Philadelphia, PA

Machine and Power Tool Safety Checklist. Version 1.1 March Chestnut Street, Suite 400, Philadelphia, PA Machine and Power Tool Safety Checklist Version 1.1 March 2017 3160 Chestnut Street, Suite 400, Philadelphia, PA 19104 215-898-4453 Machine and Power Tool Safety Checklist Overview The purpose of this

More information

Examples for Use of the MGB Inputs and Outputs

Examples for Use of the MGB Inputs and Outputs Examples for Use of the MGB Inputs and Outputs Contents Components/modules used... 2 EUCHNER... 2 Others... 2 Functional description... 2 General... 2 Connections... 3 MBG inputs and outputs... 4 Monitoring

More information

Safe Maintenance Practices for Skilled Care Facilities

Safe Maintenance Practices for Skilled Care Facilities Safe Maintenance Practices for Skilled Care Facilities Part One: Lockout/Tagout Today s Presenter: Darrell G. Toenjes, ARM, CHSP, CWCP Healthcare Practice Leader Midwest Employers Casualty Company 25 years

More information

Machine and Power Tool Safety Checklist. Version 1.2 January Chestnut Street, Suite 400, Philadelphia, PA

Machine and Power Tool Safety Checklist. Version 1.2 January Chestnut Street, Suite 400, Philadelphia, PA Machine and Power Tool Safety Checklist Version 1.2 January 2018 3160 Chestnut Street, Suite 400, Philadelphia, PA 19104 215-898-4453 Machine and Power Tool Safety Checklist Overview The purpose of this

More information

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. American Gas Safety LLC 1 05/10/2016

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. American Gas Safety LLC 1 05/10/2016 Gas Safety Products Installation, operating and maintenance 05/10/2016 American Gas Safety LLC 1 Table of contents 1 General information... 3 2 Installation... 3 2.1 Panel Mounting.... 3 2.2 Mains Supply...

More information

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. Rev: 03 Date:

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. Rev: 03 Date: Gas Safety Products Merlin 1500S Gas Interlock System Installation, operating and maintenance Rev: 03 Date: 08-01-18 1 Table of contents 1 General information... 3 2 Installation... 3 2.1 Panel Mounting....

More information

500 SERIES FOOD WASTE DISPOSERS INSTALLATION AND OPERATING MANUAL PLEASE LEAVE WITH OPERATOR 523 SERIES SERIES SERIES 17

500 SERIES FOOD WASTE DISPOSERS INSTALLATION AND OPERATING MANUAL PLEASE LEAVE WITH OPERATOR 523 SERIES SERIES SERIES 17 500 SERIES FOOD WASTE DISPOSERS INSTALLATION AND OPERATING MANUAL PLEASE LEAVE WITH OPERATOR 523 SERIES 17 525 SERIES 17 526 SERIES 17 Imperial Machine Company Limited Unit 1, Abbey Road Wrexham Industrial

More information

Occupational Safety Next Review Date: 12/20/17. Scope: University Wide Original Creation Date: 2009

Occupational Safety Next Review Date: 12/20/17. Scope: University Wide Original Creation Date: 2009 Stony Brook University EH&S Policy and Procedure Subject: 3-2 The Control of Hazardous Energy (Lockout Tagout) Published Date: 12/20/16 Occupational Safety Next Review Date: 12/20/17 Scope: University

More information

Muskogee Public Schools. Lockout/Tagout. Program

Muskogee Public Schools. Lockout/Tagout. Program Muskogee Public Schools Lockout/Tagout Program May 15, 2014 1 MUSKOGEE PUBLIC SCHOOLS PROGRAM FOR THE CONTROL OF HAZARDOUS ENERGY Table of Contents I. Scope.3 II. Purpose..3 III. Definitions Applicable

More information

Gas Safety Products. Installation, operating and maintenance. Merlin 1000S+i Gas & Electric Utility Controller. Rev: 03 Date:

Gas Safety Products. Installation, operating and maintenance. Merlin 1000S+i Gas & Electric Utility Controller. Rev: 03 Date: Gas Safety Products Merlin 1000S+i Gas & Electric Utility Controller Installation, operating and maintenance Rev: 03 Date: 14-08-18 1 Table of contents 1 General information... 3 2 Installation... 3 2.1

More information

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION and OPERATION INSTRUCTIONS INSTALLATION and OPERATION INSTRUCTIONS SINGLE DOOR freezer MODEL NOS. FN FS Finished Stainless Steel Top Non-Finished Top FS FN IMPORTANT INFORMATION This manual has been prepared to assist you in the

More information

Hot Work Policy. Department of Risk Management. 1. Purpose. 2. Authority. 3. Scope

Hot Work Policy. Department of Risk Management. 1. Purpose. 2. Authority. 3. Scope 1. Purpose The purpose of the University of Denver Hot Work policy is to protect personnel and property from a fire caused by hot work. The DU Hot Work policy defines the responsibilities and requirements

More information

TrueClean Compact CIP

TrueClean Compact CIP TrueClean Compact CIP Installation, Operation, and Maintenance Manual www.trueclean.us TrueClean Compact CIP Table of Contents Safety... 1 Important Safety Information.... 1 Introduction... 2 About This

More information

Gas Safety Products. Installation, operating and maintenance 09/05/2016. Merlin CT1650+ Gas Interlock System. S&S Northern Ltd 1

Gas Safety Products. Installation, operating and maintenance 09/05/2016. Merlin CT1650+ Gas Interlock System. S&S Northern Ltd 1 Gas Safety Products Merlin CT1650+ Gas Interlock System Installation, operating and maintenance 09/05/2016 S&S Northern Ltd 1 Table of contents 1 General information... 3 2 Installation... 3 2.1 Panel

More information

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps Note: The A/E must choose all design values in brackets below before using in project specifications 1 General 1.1 Provide UL listed and FM approved fire pump complete with pump, driver, controller and

More information

Covidien Articulating Absorba Tack Foil Pouch Leak Tester Owner s Manual IPE SN Rev 1

Covidien Articulating Absorba Tack Foil Pouch Leak Tester Owner s Manual IPE SN Rev 1 Covidien Articulating Absorba Tack Foil Pouch Leak Tester Owner s Manual IPE SN 12497 Rev 1 MANUFACTURER: INNOVATIVE PRODUCTS & EQUIPMENT, INC. 5 PROGRESS AVE TYNGSBORO, MASSACHUSETTS 01879 U.S.A Revision

More information

Troubleshooting Guide

Troubleshooting Guide Gas Safety Products 26/01/2016 S&S Northern Ltd 1 Table of contents 1 General information... 3 2 Fault LED... 3 2.1 No Power LED Illuminated... 3 2.2 Emergency Stop Fault... 3 2.3 Fan Fault... 3 2.4 Additional

More information

Gas Safety Products. Installation, operating and maintenance. Merlin 1000VW+ Gas Interlock, Gas Proving, Electric & Water Isolation System

Gas Safety Products. Installation, operating and maintenance. Merlin 1000VW+ Gas Interlock, Gas Proving, Electric & Water Isolation System Gas Safety Products Merlin 1000VW+ Gas Interlock, Gas Proving, Electric & Water Isolation System Installation, operating and maintenance Read these instructions carefully before operating or servicing

More information

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc.

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc. Chapter 1 GROUNDING AND BONDING 1 Proper grounding practices protect people from the hazards of electric shock and ensure the correct operation of overcurrent protection devices. Grounding is the intentional

More information

Gas Safety Products. Installation, operating and maintenance 11/18/2015. Merlin 1000S+ Gas Utility & Electrical Isolation Controller

Gas Safety Products. Installation, operating and maintenance 11/18/2015. Merlin 1000S+ Gas Utility & Electrical Isolation Controller Gas Safety Products Installation, operating and maintenance 11/18/2015 American Gas Safety LLC 1 Table of contents 1 General information... 3 2 Installation... 3 2.1 Panel Mounting.... 3 2.2 Power Supply....

More information

SensaGuard TM Integrated Latch Installation Instructions

SensaGuard TM Integrated Latch Installation Instructions TM Integrated Latch Installation Instructions Certifications IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE Note: Refer to Technical Specifications for Certification information and ratings. 2 TM Installation

More information

OPERATOR S MANUAL HWH HYDRAULIC SPACEMAKER ROOM EXTENSION SYSTEMS

OPERATOR S MANUAL HWH HYDRAULIC SPACEMAKER ROOM EXTENSION SYSTEMS HCORPORATIONH W R OPERATOR S MANUAL HWH HYDRAULIC SPACEMAKER ROOM EXTENSION SYSTEMS R R FEATURING: Three Dual Cylinder Room Extensions (With Synchronizing Cylinders) Single Cylinder Generator Slide HWH

More information

Liebert Small System MCD and PFH Condensers (1-5 Ton) Warranty Inspection Check Sheet

Liebert Small System MCD and PFH Condensers (1-5 Ton) Warranty Inspection Check Sheet The following information must be fully completed and forwarded to your local Liebert sales office to establish your equipment warranty. Installer Address Owner Address Owner e-mail address Installation

More information

MACHINE GUARDING. Hazards of Unguarded Machines. Occupational Safety and Health Regulations (OSHA)

MACHINE GUARDING. Hazards of Unguarded Machines. Occupational Safety and Health Regulations (OSHA) MACHINE GUARDING Hazards of Unguarded Machines Workers are exposed to unguarded or inadequately guarded machines in many workplaces. According to OSHA, workers who operate and maintain machinery suffer

More information

The Minor Servicing Exemption LOTO s Misunderstood Requirement

The Minor Servicing Exemption LOTO s Misunderstood Requirement The Minor Servicing Exemption LOTO s Misunderstood Requirement Carlos Gallegos Assistant Area Director - Response Team Aurora Area Office gallegos.carlos@dol.gov Goals Review LOTO application Define employee

More information

ISIS SAFETY SYSTEM Installation guide

ISIS SAFETY SYSTEM Installation guide ISIS SAFETY SYSTEM Installation guide CAUTION This information is designed to help suitably qualified personnel install and operate Mechan Safety equipment. Before using this product, read this guide thoroughly

More information

ENERGY CONTROL LOCKOUT/TAGOUT PROGRAM PLAN

ENERGY CONTROL LOCKOUT/TAGOUT PROGRAM PLAN ENERGY CONTROL LOCKOUT/TAGOUT PROGRAM PLAN Published by Environmental Health and Safety Last updated: 1/25/2017 Page 1 of 16 1. INTRODUCTION John Jay College Environmental Health and Safety (EHS) office

More information

Licensed Electrician Dies When Electrocuted by 480Volts Incident Number: 03KY115

Licensed Electrician Dies When Electrocuted by 480Volts Incident Number: 03KY115 Licensed Electrician Dies When Electrocuted by 480Volts Incident Number: 03KY115 An example of wires lead electrician was taping in his palm when he was electrocuted. Kentucky Fatality Assessment and Control

More information

AquaSaver DISPOSER CONTROL CENTER Installation Manual. Model AS-101K

AquaSaver DISPOSER CONTROL CENTER Installation Manual. Model AS-101K AquaSaver DISPOSER CONTROL CENTER Installation Manual Model AS-1K The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury. The Warning

More information

FB10000 Error Messages Troubleshooting

FB10000 Error Messages Troubleshooting Error ID: 66300 - UV UV System Active Alarm (UV will shut down). 66300 UV System Active Alarm (UV will shut down). Tap Get Ready. For more details open the Troubleshooting guide This UV error

More information

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY 24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY 06/13/2011 Rev. 6 Pollution Control Unit PCU CORE CONNECTIONS, 3/8" NPT CONNECTION, ONE PER MODULE LINE FROM PACKAGE MUST BE BRANCHED TO EACH MODULE..

More information

Multifunctional Gate Box MGB. More than safety.

Multifunctional Gate Box MGB. More than safety. Multifunctional Gate Box MGB More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 98. Around the world the Swabian specialists

More information

Air Compressor Electrical Fire

Air Compressor Electrical Fire Purpose To share lessons learned gained from incident investigations through a small group discussion method format. To understand lessons learned through a Systems of Safety viewpoint. This material was

More information

Model 3.6m. User Manual Original instructions

Model 3.6m. User Manual Original instructions Model 3.6m User Manual Original instructions CONTENTS Introduction 3 Description 4 General Do s and Don ts 5 Controls and operation 7 Smoke alarms 9 Emergency procedures 11 Fault finding 19 Changing smoke

More information

You and OSHA. What and How To Comply. PRESENTED BY: Joan M. Spencer Compliance Assistance Specialist Tampa Area Office

You and OSHA. What and How To Comply. PRESENTED BY: Joan M. Spencer Compliance Assistance Specialist Tampa Area Office You and OSHA What and How To Comply PRESENTED BY: Joan M. Spencer Compliance Assistance Specialist Tampa Area Office 813-626-1177 OSHA s Mission To Assure So Far as Possible Every Working Man and Woman

More information

We make your Workplace Safe

We make your Workplace Safe We make your Workplace Safe Our consultancy services include, but are not limited to the following; Health and Safety Audits. Health and Safety Training. CE Marking. Writing safety policies and procedures.

More information

MACHINE GUARDING: PROTECTING YOU FROM HAZARDS

MACHINE GUARDING: PROTECTING YOU FROM HAZARDS MACHINE GUARDING: PROTECTING YOU FROM HAZARDS This easy-to-use Leaders Guide is provided to assist in conducting a successful presentation. Featured are: INTRODUCTION: A brief description of the program

More information

OPERATING & SERVICE INSTRUCTION MANUAL FOR

OPERATING & SERVICE INSTRUCTION MANUAL FOR OPERATING & SERVICE INSTRUCTION MANUAL FOR THETFORD INTERNATIONAL ULTIMATE 5P COMPACTORS AND ASSOCIATED EQUIPMENT Printed in England by Thetford International Compactors Ltd COPYRIGHT 1 LIST OF CONTENTS

More information

More than safety. Operating Instructions Safety Switch CET.-AS-...-CB-... (Multicode)

More than safety. Operating Instructions Safety Switch CET.-AS-...-CB-... (Multicode) More than safety. Operating Instructions Safety Switch CET.-AS-...-CB-... (Multicode) Contents Correct use 3 Possible combinations for CET components 4 Exclusion of liability and warranty 4 General safety

More information

Installation Supplement

Installation Supplement Installation Supplement INTERLOCK OPTIONS Venting Options for Interlocking an Exhaust System to a Wood Stone Oven ALL MODELS Toll Free 800.988.8103 Tel 360.650.1111 Fax 360.650.1166 www. DOC NO M0077.03

More information

This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly qualified.

This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly qualified. SERVICE MANUAL ERA & EBD SERIES ELECTRIC FRYERS WITH KLEENSCREEN PLUS FILTRATION SYSTEMS 2ER50AF KLEENSCREEN FRYER BATTERY MODEL ML MODEL ML 1ER50A 136730 2XER50AF 136747 1E50BD 136730 2XE50BDF 136747

More information

CONTROL CENTRE FOR CENTRALISED LUBRICATION SYSTEM WITH PROGRESSIVE FEEDER CCL Alpha

CONTROL CENTRE FOR CENTRALISED LUBRICATION SYSTEM WITH PROGRESSIVE FEEDER CCL Alpha I2119-E-02.05 CONTROL CENTRE FOR CENTRALISED LUBRICATION SYSTEM WITH PROGRESSIVE FEEDER CCL Alpha Model No. 906716-E USER S MANUAL CONTENTS 1. DESCRIPTION Page 2 2. DATA Page 3 3. HANDLING Page 3 4. ELECTRIC

More information

OUTLINE FOR FIRE PREVENTION ACTIVITY

OUTLINE FOR FIRE PREVENTION ACTIVITY OUTLINE FOR FIRE PREVENTION ACTIVITY Background Buildings under construction present unique fire exposures that require special attention. Fires can result in major losses and long delays in the completion

More information

ARCHIVE GUARDING OF PAPER BALING PRESSES

ARCHIVE GUARDING OF PAPER BALING PRESSES GUARDING OF PAPER BALING PRESSES NOTE The technical information in this book was current at the time of printing in 1984. While the guarding principles are still valid, the information does not necessarily

More information

First of all, what is a safety-related

First of all, what is a safety-related Safety-Related Control Systems First of all, what is a safety-related control system (often abbreviated to SRCS)? It is that part of the machine control system which prevents a hazardous condition from

More information

YCIV Hz & Hz

YCIV Hz & Hz YCIV 0590-1500 50Hz & 0157-0397 60Hz Start-up Checklist SERVICE POLICY & PROCEDURES Supersedes: Nothing Form 201.23-CL1 (309) Commissioning PREPARATION Commissioning of this unit should only be carried

More information

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet The following information must be fully completed and forwarded to your local Liebert sales office to establish your equipment warranty. Installer Address Owner Address Owner e-mail address Installation

More information

Operational Overview and Controls Guide

Operational Overview and Controls Guide DOCUMENT: ECSEQ2-2 EFFECTIVE: 02/26/10 SUPERSEDES: 02/14/07 Operational Overview and Controls Guide Standard Two or Three Pump Type VFD Booster Controls 6700 Best Friend Road. Norcross, GA 30071. (770)

More information

MERLIN RANGE KITCHEN EQUIPMENT CT1200S CT1250

MERLIN RANGE KITCHEN EQUIPMENT CT1200S CT1250 MERLIN RANGE KITCHEN EQUIPMENT CT1250 CT1200S MERLIN RANGE CT1250 KITCHEN EQUIPMENT Merlin CT1250 The Merlin CT1250 ventilation interlock system, with built in current monitoring, is designed specifically

More information

AREMA C&S Manual 2018 (Includes 2018 Revisions) Volume 4 Index. Part C Type & Subject Pages Status

AREMA C&S Manual 2018 (Includes 2018 Revisions) Volume 4 Index. Part C Type & Subject Pages Status SECTION 16 - VITAL CIRCUIT AND SOFTWARE DESIGN 16.1 Recommended Nomenclature 16.1.1 37-3 Recommended Circuit Nomenclature 17 Revised 2012 16.2 Recommended Symbols 16.2.1 37-3 Recommended Graphical Symbols

More information

Manual / Handbuch Spare parts list / Ersatzteilliste

Manual / Handbuch Spare parts list / Ersatzteilliste Manual / Handbuch Spare parts list / Ersatzteilliste Equipment Imp.-Exp. GmbH Zitterpappelweg 9 D - 22391 Hamburg Tel.: + 49 40 60009468-0 Fax: + 49 40 536 75 01 E - M a i l : i n f o @ w e s c o - n a

More information

ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications

ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications ECS PROTECTOR ECS Protector - PSV-D (PSV-DE) Specifications Stock Number : Service Pressure: System Connection: Electrical Connection: Temperature Range: Dimensions Vent Assembly: For use under U.S. Patents

More information

Hydraulic Residential Elevator OWNER S MANUAL

Hydraulic Residential Elevator OWNER S MANUAL Hydraulic Residential Elevator OWNER S MANUAL Congratulations on your purchase of a residential elevator from Federal Elevator. We appreciate your business and are confident that the unit we carefully

More information

Operations Manual. 10 / 12 / 18 Vacuum Cool Tower Dryer Series MATHEWS COMPANY. Volume

Operations Manual. 10 / 12 / 18 Vacuum Cool Tower Dryer Series MATHEWS COMPANY. Volume Volume 1 MATHEWS COMPANY 10 / 12 / 18 Vacuum Cool Tower Dryer Series 10 Vacuum Cool Tower 2011 Mathews Company 500 Industrial Avenue Crystal Lake, IL 60012 USA Toll Free Number: (800) 323 7045 www.mathewscompany.com

More information

Installation & Operation Instructions

Installation & Operation Instructions Installation & Operation Instructions Installation Precautions This Zoning System must be installed by a qualified HVAC Contractor! Caution - Electrical Hazard Can cause personal injury or equipment damage.

More information

Volume MATHEWS COMPANY. Legacy Series L1250 /L1350 /L2550 /L2650 /L2700 /L3100 /L3105 /L4145 /L5175. Operations Manual

Volume MATHEWS COMPANY. Legacy Series L1250 /L1350 /L2550 /L2650 /L2700 /L3100 /L3105 /L4145 /L5175. Operations Manual Volume 1 MATHEWS COMPANY Legacy Series L1250 /L1350 /L2550 /L2650 /L2700 /L3100 /L3105 /L4145 /L5175 2011 Mathews Company 500 Industrial Avenue Crystal Lake, IL 60012 USA Toll Free Number: (800) 323 7045

More information

Bliss Box Former Troubleshooting. 6.1 Troubleshooting Chart. Troubleshooting INTRODUCTION SAFETY PROCEDURES

Bliss Box Former Troubleshooting. 6.1 Troubleshooting Chart. Troubleshooting INTRODUCTION SAFETY PROCEDURES 6.0 Bliss Box Former 1.0 INTRODUCTION Table 6-1 provides a logical sequence of tests that are designed to isolate problems with the Bliss Box Former machines. This table includes a list of probable causes

More information

Condensing Unit Installation and Operating Instructions

Condensing Unit Installation and Operating Instructions Bulletin WCU_O&I 01 June 2003 Condensing Unit Installation and Operating Instructions WCU Air Cooled Condensing Unit Table of Contents Section 1. Section 2. Section 3. Section 4. Section 5. Section 6.

More information

1 Window Blanket 2 Sets forcible entry tools including a Rabbit Tool/Hydra Ram 2 Six foot hooks

1 Window Blanket 2 Sets forcible entry tools including a Rabbit Tool/Hydra Ram 2 Six foot hooks 1. EQUIPMENT 2. USE 1 Window Blanket 2 Sets forcible entry tools including a Rabbit Tool/Hydra Ram 2 Six foot hooks 2.1 The fire window blanket is deployed from the floor above the fire. 2.2 To cover a

More information

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY 24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY 11/12/2012 Rev. 10 Pollution Control Unit PCU CORE CONNECTIONS, 3/8" NPT CONNECTION, ONE PER MODULE LINE FROM PACKAGE MUST BE BRANCHED AND ADAPTED TO EACH

More information

F&S Control of Hazardous Energy Program

F&S Control of Hazardous Energy Program University of Illinois at Urbana-Champaign Facilities & Services Division of Safety and Compliance F&S Control of Hazardous Energy Program February 2013 Last updated by: j. neighbors Page 1 of 12 Last

More information

Operating instructions Oil condensing boiler

Operating instructions Oil condensing boiler Operating instructions Oil condensing boiler COB COB-CS Boiler for heating Boiler with stratification cylinder Wolf GmbH Postfach 1380 D-84048 Mainburg Tel. +49-8751/74-0 Fax +49-8751/741600 Internet:

More information

CONTROL CENTRE FOR CENTRALISED LUBRICATION SYSTEM WITH PROGRESSIVE FEEDER AND SPRAY NOZZLES CCL Alpha Spray

CONTROL CENTRE FOR CENTRALISED LUBRICATION SYSTEM WITH PROGRESSIVE FEEDER AND SPRAY NOZZLES CCL Alpha Spray I2130-E-05.04 CONTROL CENTRE FOR CENTRALISED LUBRICATION SYSTEM WITH PROGRESSIVE FEEDER AND SPRAY NOZZLES CCL Alpha Spray Model No. 907044 USER S MANUAL CONTENTS 1. DESCRIPTION Page 2 2. DATA Page 2 3.

More information

T-6B Electrical System. Created: 24 Aug 2015 Updated: 30 Aug 2015 T6BDriver.com

T-6B Electrical System. Created: 24 Aug 2015 Updated: 30 Aug 2015 T6BDriver.com T-6B Electrical System Created: 24 Aug 2015 Updated: 30 Aug 2015 T6BDriver.com Objectives Identify power sources of electrical system Understand electrical distribution within system Identify location

More information

CS1000. Single Pole Plugs & Connectors up to 400A, 1000VAC Featuring: Silver-Nickel, Butt-Style Contacts. Locking Pin. Finger Guard (IP2X)

CS1000. Single Pole Plugs & Connectors up to 400A, 1000VAC Featuring: Silver-Nickel, Butt-Style Contacts. Locking Pin. Finger Guard (IP2X) New Product Announcement Issue date: 14 June 2012 CS1000 new product description Single Pole Plugs & Connectors up to 400A, 1000VAC Featuring: Silver-Nickel, Butt-Style Contacts Locking Pin Removable Unlocking

More information

Original operating instructions Safety switch with guard locking AC901S AC902S

Original operating instructions Safety switch with guard locking AC901S AC902S Original operating instructions Safety switch with guard locking AC901S AC902S 7390914/03 01/2017 Contents 1 Preliminary note...4 1.1 Explanation of symbols...4 2 Safety instructions...4 3 Items supplied...5

More information

FOOD WASTE DISPOSERS MODELS FD4-150 FD4-200 FD FORM (May 2015) S. RIDGE AVENUE TROY, OHIO

FOOD WASTE DISPOSERS MODELS FD4-150 FD4-200 FD FORM (May 2015) S. RIDGE AVENUE TROY, OHIO FOOD WASTE DISPOSERS MODELS FD4-150 FD4-200 FD4-300 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 937 332-3000 www.hobartcorp.com FORM 38476 (May 2015) HOBART CORPORATION, 2014 2 TABLE OF CONTENTS SAFETY...4

More information

SECTION 1-1 SAFETY PRECAUTIONS DOUBLE ARM MIXER CHAPTER 1: SAFETY

SECTION 1-1 SAFETY PRECAUTIONS DOUBLE ARM MIXER CHAPTER 1: SAFETY SECTION 1-1 SAFETY PRECAUTIONS Peerless mixers are designed and built to operate as safety as possible. However, if the precautions and procedures explained in this manual are not followed at all times,

More information

KWT-8000FM AUTO FILLING MACHINE OPERATION MANUAL KWT MACHINE SYSTEMS CO., LTD.

KWT-8000FM AUTO FILLING MACHINE OPERATION MANUAL KWT MACHINE SYSTEMS CO., LTD. KWT-8000FM AUTO FILLING MACHINE 37-161000 OPERATION MANUAL KWT MACHINE SYSTEMS CO., LTD. No. 21, Taiping 21 Street, Taiping City, Taichung Hsien 411, Taiwan TEL : 886-4-22773390 FAX : 886-4-22773412 E-MAIL:

More information

Control Panel with Across The Line Starters

Control Panel with Across The Line Starters ECO SMART Station ATL Control Panel with Across The Line Starters The ECO SMART STATION ATL is a pre-engineered duplex control panel designed specifically for municipal lift station applications. Housed

More information

Design-In Health and Safety Guarding. Thermal April 2010

Design-In Health and Safety Guarding. Thermal April 2010 Design-In Health and Safety Guarding Thermal April 2010 8. Safeguarding 2 8.1. Fundamentals for Safeguarding 2 8.2. Guard Design 2 8.2.1. Point-of-Operation/Machine Guarding 2 8.2.2. Thermal Hazard Guarding

More information

SECTION ROTARY-SCREW WATER CHILLERS

SECTION ROTARY-SCREW WATER CHILLERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Factory-assembled packaged chiller. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled water connections. E. Electrical power connections.

More information

Deluge System. Pneumatic Release. Deluge System. Pneumatic Release

Deluge System. Pneumatic Release. Deluge System. Pneumatic Release Deluge System Pneumatic Release Deluge System Pneumatic Release When the fixed temperature release () is activated by fire, pressure in the release system escapes from the open device, allowing the pneumatic

More information

UC700 EMERGENCY TRANSFER SYSTEM SPECIFIER S HANDBOOK. 40 Dale Street West Babylon, NY Ph: Fx:

UC700 EMERGENCY TRANSFER SYSTEM SPECIFIER S HANDBOOK. 40 Dale Street West Babylon, NY Ph: Fx: UC700 EMERGENCY TRANSFER SYSTEM SPECIFIER S HANDBOOK 40 Dale Street West Babylon, NY 11704 Ph: 631-753-9550 Fx: 631-753-9560 www.unionconnector.com Emergency Automatic Transfer System STANDARD SPECIFICATIONS

More information

PROFESSIONAL S2 SAFE USER GUIDE ELECTRONIC LOCK USER GUIDE.

PROFESSIONAL S2 SAFE USER GUIDE ELECTRONIC LOCK USER GUIDE. USER GUIDE PROFESSIONAL S2 SAFE ELECTRONIC LOCK USER GUIDE www.chubbsafes.com Chubb is owned by Chubb plc and is a registered trademark used under license General Description The lock is operated by a

More information

ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications

ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications ECS Protector - PSV-D (PSV-DE) Specifications For use under U.S. Patents 8,720,591, 9,144,700, 9,186,533 and 9,610,466 Stock Number : Service Pressure: System Connection: Electrical Connection: Temperature

More information

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector Wiring Instructions for the 900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector CAUTION: FAILURE TO INSTALL OR ADJUST PROPERLY MAY RESULT IN INJURY OR

More information

Preparing the Cabinet

Preparing the Cabinet Preparing the Cabinet Uncrating and Inspection Remove all crating material before operating. Carefully inspect cabinet for hidden damage. If damage is discovered, file your claim immediately with the transport

More information

Datasheet - AZM ZRK 24 VAC/DC Solenoid interlock / AZM 170

Datasheet - AZM ZRK 24 VAC/DC Solenoid interlock / AZM 170 http://www.schmersal.net/datenblatt?lang=en&produkt=ax4732937owob0f8o2640384... 29/09/2011 Datasheet - AZM 170-11ZRK 24 VAC/DC Solenoid interlock / AZM 170 Preferred typ thermoplastic enclosure Double-insulated

More information

SAFEMASTER STS. The key to more safety. Our experience. Your safety.

SAFEMASTER STS. The key to more safety. Our experience. Your safety. SAFEMASTER STS The key to more safety Modular safety switches and key transfer systems for the highest requirements. Now also available in a fibre reinforced polymer version! Our experience. Your safety.

More information

KwêBeams Effective wire free outdoor early warning system

KwêBeams Effective wire free outdoor early warning system 1 KwêBeams Effective wire free outdoor early warning system Features: - Easy to install & use - Operates on 868Mhz frequency (less congested to avoid signal jamming) - All sensors with built in sirens,

More information

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS STW & STW-T SAFE AREA AIR WARMERS HFT, AFT & SAT TYPE AIR THERMOSTATS Please read these

More information

Operating and Service Manual

Operating and Service Manual Operating and Service Manual TR-3-C 900 2000 PACKAGING TECHNOLOGY EN ISO 9001 70 100 M 745 EAM-MOSCA Corp. 675 Jaycee Drive Valmont Ind. Pk. Telephone (570) 459-3426 Fax (570) 455-2442 TR-3-C 1-1 CONTENTS

More information

FAULT CODES. Included in this section are instructions to Reset the two Hot Tank Overload Devices (High Safety Limit).

FAULT CODES. Included in this section are instructions to Reset the two Hot Tank Overload Devices (High Safety Limit). FAULT CODES Fault Code Index 1. Blue Chilling LED Flashing Cold Sensor Fault 2. Red Heating LED Flashing Hot Sensor Fault 3. Green LED Flashing Filter Service Alert 4. All but Power Button LEDs Flashing

More information

Machine Guarding and Safety

Machine Guarding and Safety Machine Guarding and Safety Many thanks for clicking on this document. Please let us introduce selected highlights from our Machine Guarding and Safety offer. Related Industries: Food and Beverage Industry

More information

Electronic Refrigerant Gas Detectors

Electronic Refrigerant Gas Detectors 1.0 Introduction Electronic Refrigerant Gas Detectors Electronic Devices Ltd (EDL) is our preferred supplier for ammonia and type L1 refrigerant detection systems. CBISS and Vaisala are our preferred suppliers

More information

Pneumatic Heat Press. Revision: 3 Operators Manual

Pneumatic Heat Press. Revision: 3 Operators Manual Pneumatic Heat Press Revision: 3 Operators Manual Wader Labelling Systems Ltd 2003 Location and Set-up. The press must be located near to a filtered air supply and a 240v singlephase mains supply. Ensure

More information

MEV Ecosmart. Installation and Maintenance. Continuous Mechanical Extract Ventilation Units. 1.0 Introduction

MEV Ecosmart. Installation and Maintenance. Continuous Mechanical Extract Ventilation Units. 1.0 Introduction MEV Ecosmart Continuous Mechanical Extract Ventilation Units Installation and Maintenance ICUDIG MEV-SVS 1.0 Introduction uaire's MEV Ecosmart units are designed to provide continuous mechanical extract

More information

Lockout Tagout Specific Procedure

Lockout Tagout Specific Procedure Machine: Boiler : Control panel on front of unit 3. Turn off the (Electric/natural gas) energy sources by placing energy isolating Control panel on front of unit Panel, breaker #5. 7. 9 Ball valve on natural

More information

Table of correspondence between ISO :2003, ISO :2003, ISO :2007 and the new ISO 12100:2010. Date of document

Table of correspondence between ISO :2003, ISO :2003, ISO :2007 and the new ISO 12100:2010. Date of document ISO/TC 199 N 833 ISO/TC 199 Safety of machinery E-mail of Secretary: christian.thom@din.de Secretariat: DIN Table of correspondence between ISO 12100-1:2003, ISO 12100-2:2003, ISO 14121-1:2007 and the

More information

Selecting Safeguards

Selecting Safeguards Selecting Safeguards Chris Soranno Safety Compliance Manager Omron STI October 14 th 16 th, 2013 ~ Indianapolis, Indiana USA DISCLAIMER This presentation does not advocate any particular solution, product,

More information

Dust Suppression System

Dust Suppression System INTRODUCTION. Many processes create clouds of fine particle airborne dust while transferring or transporting bulk materials. This airborne dust is not only annoying but can be toxic and debilitating to

More information

Swaging Machine Type H50-46ECO

Swaging Machine Type H50-46ECO ENDEAVOUR Int. Ltd. Tel +44 (0) 1225 446770 Fax +44 (0) 1225 446775 USER MANUAL Swaging Machine Type H50-46ECO Website: www.hydralok.net CONTENTS WARRANTY CONDITIONS... 3 EC DECLARATION OF CONFORMITY...

More information