Good News at Home Hankey & Brown Inspection Service June 2013
|
|
- Stella French
- 5 years ago
- Views:
Transcription
1 Good News at Home Hankey & Brown Inspection Service June 2013 Last month we discussed air conditioner maintenance. This month s topic is: Attic Ventilation. Next month s topic is fire protection in homes with attached garages. Most Twin Cities homes have an attic below all or portions of the roof. The attic can become quite hot in the summer if it is not adequately ventilated. An overheated attic creates two adverse conditions: 1. The heat can damage and/or shorten the life of the roofing. (Excess heat can bake the volatiles out of asphalt shingles.) This the reason that asphalt shingle manufacturer s will often not honor a shingle warranty claim if it can be shown that the roof - attic was not ventilated to their specifications. 2. Excessive heat in the attic can increase the cooling costs for the home. Attic ventilation is also beneficial in winter. A well vented attic helps keep the roof sheathing close to the temperature of any snow on the roof. This reduces the potential for ice dams by minimizing roof snow melt. Proper attic ventilation on simple roofs is not complex. A straight gable with good overhangs is a good example of ideal roof ventilation. The 1/300 ratio shown in the drawing assumes the ceiling has a good air and vapor barrier. Figure 1 Unfortunately, many Twin Cities homes do not have a simple gable roof with one attic. One common difficult to vent house is the typical 1-1/2 story design popular from1930 to the These homes have multiple attics.
2 Figure 2 Figure 2 discusses insulation, but each of the 4 attics shown must be ventilated unless the roof itself is insulated. The decision of how to insulate and ventilate a story and a half house is based by whether or not a space below the roof is to be unconditioned attic, or a conditioned finished space. Figure 3 shows two ways the attic can be insulated. Note that option B creates a warm space that is NOT ventilated. What is NOT shown in option A is a vent for air to enter the attic. The only vent shown is near the top of the knee wall. This vent lets air out, in order for that vent to work; there must be an air inlet. Traditionally, the air inlets installed for knee wall spaces were simple louvers known as gable vents, places in the gable end walls of the knee wall attic. Often these gable vents do not work well since they often can not be low enough to create a convective loop of cool air in low and warm our out near the top of the knee wall. Fortunately one roof vent manufacturer has created a Smart Vent that integrates into the roof and works as either an inlet or outlet vent depending on where it is placed on the roof. See Figure 4.
3 Figure 3 Figure 4 Several design factors are important in successful venting. 1. The best vents are continuous along the soffit (eave) and ridge, since this helps all areas of the roof receive uniform air flow.
4 2. The ventilation must be balanced such that the air flow out is matched by an equal amount of air coming into the attic. (Most manufacturers recommend more air intake than exhaust to ensure the exhaust vents do not create negative air pressure in the attic.) 3. Types of vents should not be mixed. Standard box vents (roof hats) should not be placed below ridge vents as this will interrupt air flow to the ridge. 4. Gable vents typically do not establish a convection flow of cool air in and warm air out. 5. When having the house reroofed, discuss venting carefully with the roofing contractor. Ridge vents generally look much better than multiple box vents, and usually work better. There are numerous types of ridge vents. Most authorities agree that those with wind baffles tend to perform better in windy conditions. 6. Turbine vents tend to concentrate air flow in a few places and may leave other areas with little air flow. Further, turbine vents depend on bearings, which can fail with age and/or become noisy. Also turbine vents are vulnerable to powder snow entry. 7. When replacing box vents, be sure the roofer centers the vent in a clear opening, and be sure to specify bird resistive vents. (Most roofers use these now.) Vents require little maintenance; however their appearance can indicate their effectiveness. 1. Most soffit vents have small openings and screening. If the vent is more than a year or so old and has NO dust in it, it probably isn t working. Modern perforated metal soffit panels are often installed over old wood soffits. We occasionally find that old wood soffits were not cut open to provide a suitable path for air to reach the attic. 2. Those small openings in the soffit vents are highly vulnerable to PAINT. Any
5 paint other than the original factory finish will typically clog the vent openings. Replacement would be the best remedy. 3. Attic re-insulation will clog the opening from the soffit into the attic unless insulation baffles are installed prior to re-insulating. Previous issues of our newsletter are archived at our website: There is also a link to subscribe to the newsletter at the same site. Have a great month.
Joe Konopacki 10/26/2016. Attic & Crawlspace Ventilation. What results from poor ventilation? Attic & Crawlspace Ventilation. Overview Why ventilate?
Joe Konopacki Multifamily Property Management & Rehab Home Inspections IL Licensed Home Inspector Building Science BPI Building Analyst RESNet Energy Rater BPI Trainer What results from poor ventilation?
More informationAttic Condensation. Presented by: Joan Maisonneuve Technical Services
Attic Condensation Presented by: Joan Maisonneuve Technical Services Scope of the Presentation How does moisture get into the attic? Blowing snow Moisture from the outdoor air Moisture from side-vents
More informationBuilder s Technical Sessions. Attic Ventilation. Presented by: Rob Kaethler. Presented in Partnership with: Insert your logo here
Builder s Technical Sessions Attic Ventilation Presented by: Rob Kaethler Presented in Partnership with: Insert your logo here Residential Ventilation Agenda Principles of Ventilation Types of Ventilation
More informationPage 1 of 5 Does your dryer vent work? Home laundry facilities have changed dramatically in the past 60 years. A wringer washer and concrete tubs in the basement with clothes lines outdoors or hanging
More informationThis booklet is a compilation of tips and the answers to some of the questions most commonly asked at Air Vent s Attic
ATTIC VENTILATION HAS NEVER BEEN MORE IMPORTANT. Construction practices and products have changed dramatically in recent decades. Windows and doors are more airtight, insulation levels have increased,
More informationVentilation Standards
C e r t a i n T e e d S h i n g l e A p p l i c a t o r s M a n u a l Ventilation Standards 7 and Systems YOUR OBJECTIVE: To learn how different attic ventilation systems are designed and which designs
More informationGambrel or Mansard Roofs and Ice damming
Gambrel or Mansard Roofs and Ice damming It s no coincidence that ice damming occurs most pervasively in the mansard or gambrel styled roof. The design was popularised both in America and France by virtue
More informationAttic ventilation options can be confusing to roofing contractors
30 www.professionalroofing.net JANUARY 2014 Attic ventilation options can be confusing to roofing contractors by Joan P. Crowe, AIA Attic ventilation can be a confusing, complex subject and is the topic
More informationInsulating Unvented Attics With Spray Foam
Insulating Unvented Attics With Spray Foam Closed-cell polyurethane foam provides the insulation, air barrier, and vapor retarder necessary for an unvented attic assembly by James Morshead As a general
More informationbig building site We have the product for you 1 Ventilateur Optimum
big building site We have the product for you 12 24 36 1 www.condor.pro An ecological comfort whitout maintenance Optimum guarantee a first quality and reliable product. We are proud to present to our
More informationOFF-RIDGE VENTILATION PRODUCT BROCHURE
OFF-RIDGE VENTILATION PRODUCT BROCHURE UPGRADE YOUR AIRFLOW IPS Roofing Products ventilation is the most efficient attic ventilation product line in the industry. Constructed of a heavy gauge aluminum,
More informationV ENTILATION V IEWS. News, opinions, ideas and technical advice from the ventilation specialists at Air Vent
V ENTILATION V IEWS News, opinions, ideas and technical advice from the ventilation specialists at Air Vent I s s u e F o c u s : Ridge Vent and Power Vent Installation Tips As a manufacturer of attic
More informationPrinciples of Attic Ventilation. Acomprehensive guide toplanning The BalancedSystem for attic ventilation
Principles of Attic Ventilation Acomprehensive guide toplanning The BalancedSystem for attic ventilation Introduction: The Year-Round Benefits of Proper Attic Ventilation...1 Section 1: How Ventilation
More informationGUIDE TO GOOD VENTILATION
GUIDE TO GOOD VENTILATION Printed in Canada www.proventilator.com Canplas, the manufacturer of the Duraflo PROventilator, has over 45 years of building materials manufacturing and product innovation experience.
More informationMeasurement of Attic Temperatures and Cooling Energy Use in Vented and Sealed Attics in Las Vegas, Nevada
building science.com 2008 Building Science Press All rights of reproduction in any form reserved. Measurement of Attic Temperatures and Cooling Energy Use in Vented and Sealed Attics in Las Vegas, Nevada
More informationEnergy problems in small apartment buildings
Energy problems in small apartment buildings Uneven heating and drafts, window condensation, complaints about odors and burned out lamps these are common problems in four-unit to eight-unit apartment buildings.
More informationabout your house Attic Venting, Attic Moisture, and Ice Dams Figure 1 Typical attic floor insulations
about your house CE 13 Attic Venting, Attic Moisture, and Ice Dams It is rare for Canadians to visit their attics. For many years building codes have required high levels of attic insulation, making attics
More informationNatural Ventilation. 3Ji+J49 83P. Louvers and Roof Ventilators. ood CONSERVATION AND RENEWABLE ENERGY INQUIRY AND REFERRAL SERVICE
DOEEE-0255 3Ji+J49 83P G ood ventilation is the key to a comfortable and healthy home. You can cool your home and remove hot, stale air by opening and closing doors and windows. This natural ventilation
More informationIce Dam Symptoms and Solutions for a Cold-Climate Roof
Ice Dam Symptoms and Solutions for a Cold-Climate Roof Matt Dries Dr. Robert Seavey Assisted by Collin Coltman and Kristel Spiegelberg Sustainable Systems Management: Building Science and Technology University
More informationfieldwork report contains the Functional
December 6, 2010 Dear Bill and Ann, On October 2, 2010, Cities Inspection Service, Inc. completed a home inspection of the property located at 2344 Arbour Lane, St. Paul, Minnesota for you. Doug Hastings
More informationraft-r-mate Attic Rafter Vent with optional air stop/insulation block A SIMPLE, ECONOMICAL WAY TO REDUCE ENERGY WASTE AND PREVENT ROOF DAMAGE.
Attic Rafter Vent with optional air stop/insulation block A SIMPLE, ECONOMICAL WAY TO REDUCE ENERGY WASTE AND PREVENT ROOF DAMAGE. FEATURES AND BENEFITS Ventilation channel and air stop/ insulation block
More informationEnergy Conservation Measures For the Town of Lakeville. Locations Town Hall Fire Department Police Department Council on Aging
Energy Conservation Measures For the Town of Lakeville Locations Town Hall Fire Department Police Department Council on Aging March 05 Location Town Hall 36 Bedford Street Energy Conservation Measures
More informationWHY IS BUILDING SCIENCE IMPORTANT?
OUTLINE Why Building Science is Important Building Science Key Components Controlling Air Flow Controlling Thermal Flow Controlling Moisture Flow ENERGY STAR Solutions Action Plan WHY IS BUILDING SCIENCE
More informationVentilation Installation Professional
Ventilation Installation Professional Education and development program for attic ventilation systems Product Knowledge Contents: Page Introduction: 3 Sections: Section 1: The Benefits of Attic Ventilation
More informationUnvented Roof Assemblies for All Climates by Chris Schumacher
2007 Building Science Press All rights of reproduction in any form reserved. building science.com 2007 Building Science Press All rights of reproduction in any form reserved. Building Science Digest 149
More informationC e r t a i nte e d. 5-Star Warranty
C e r t a i nte e d 5-Star Warranty The best-performing warranty in the industr y. BE SURE SureStart PLUS 5-STAR Warranty The best-performing warranty in the industry. Some of the things you enjoy most
More informationThe following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on
HOME PROPERTY SCAN INSPECTIONS The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on January 11, 2010 and
More informationShown in Colonial Slate
C e r t a i nte e d D e s i g n e r S h i n g l e s Shown in Colonial Slate Shown in Weathered Wood You know it, when you see it. It s not just a roof. It s a CertainTeed roof. Quality. Durability. Style.
More informationWHAT S UNDER YOUR ROOF?
WHAT S UNDER YOUR ROOF? ROOF LINE DO YOU WANT A HOT BOX ATTIC CEILING OR A COOL CLOSED ATTIC? Smart Choice for Smart Minds! ROOF LINE ATTIC CEILING WHY SPRAY FOAM? It reduces sensible and latent heat loads.
More informationSolar Powered Roof Ventilation Fan
Solar Powered Roof Ventilation Fan Overview High Efficient Excellent Ventilation Free Solar Panel Power BLDC Motor Quiet Running Strong Fan Case Durable In Use Energy Saving Ecofriendly Easy Installation
More informationPROTECTING FIRE SPRINKLER SYSTEM PIPES FROM FREEZING IN CHAPTER FACILITIES
James R. Favor & Company PROTECTING FIRE SPRINKLER SYSTEM PIPES FROM FREEZING IN CHAPTER FACILITIES A resource for Fraternity and Sorority House Corporation Officers Prevent Your Sprinkler System from
More informationAvailable online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015
Available online at www.sciencedirect.com ScienceDirect Energy Procedia 7 (215 ) 67 72 6th International Building Physics Conference, IBPC 215 Effect of attic insulation thickness and solar gain in a mild
More informationHome Inspection Report
Home Inspection Report John Property Address: 123 Main Street Fredericksburg VA 22401 ABI Home Inspections Shannon Lewis PO Box 244 Lively, VA 22507 (804) 724-4468 Virginia Licensed Home Inspector #3380000749
More informationNew RepairBase Line Item additions for the Update
Equipment Rental Equipment Rental Scissor Lift Does not Include Operator Charge Per Day Equipment Rental Compact Tractor Does not Include Operator Charge Per Day Equipment Rental Trenching Machine Does
More informationA DO-IT-YOURSELF GUIDE TO ENERGY STAR HOME SEALING SEALING AIR LEAKS AND ADDING ATTIC INSULATION
For more information www.energystar.gov or call 1.888.STAR.YES (1.888.782.7937). United States Environmental Protection Agency Office of Air and Radiation (6202J) EPA 430-F-04-024 September 2006 A DO-IT-YOURSELF
More informationUnited States Environmental Protection Agency
For more information www.energystar.gov or call 1.888.STAR.YES (1.888.782.7937). United States Environmental Protection Agency Office of Air and Radiation (6202J) EPA 430-F-04-024 August 2007 Recycled/Recyclable
More informationWelcome! Today s topic: Weatherization and Seasonal Maintenance
Welcome! Today s topic: Weatherization and Seasonal Maintenance Weatherization and Seasonal Maintenance Presented by Monique Johnson Environmental Green Solutions, LLC It's That Time Of The Year Again!!!
More informationACCA Quality Homes ACCA 12 QH 2011 (Existing Home Evaluation and Performance Improvement) Developed in cooperation with RESNET
ACCA Quality Homes ACCA 12 QH 2011 (Existing Home Evaluation and Performance Improvement) Developed in cooperation with RESNET Wes Davis Director, Quality Assured Program Air Conditioning Contractors of
More informationUniversity of Illinois at Urbana-Champaign Small Homes Council-Building Research Council COUNCIL NOTES. ::s >
~ University of Illinois at Urbana-Champaign Small Homes Council-Building Research Council COUNCIL NOTES ~ e ::s 0 > INTRODUCTION Where there is insufficient moisture in the air, the occupants of a home
More informationD. Fabrication: Steel or Aluminum with baked enamel off-white finish. B. Type: Square and rectangular, adjustable pattern, multi-louvered diffuser.
SECTION 23 37 00 - AIR OUTLETS AND INLETS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Diffusers. 2. Registers 3. Grilles. PART 2 - PRODUCTS 2.1 ROUND CEILING DIFFUSERS B. Product Description:
More informationRE: Extreme Cold: Preventing Ice Dams, Frozen Pipes February 13, 2015
Office of Risk Management - Risk Alert - No. 2015-06 RE: Extreme Cold: Preventing Ice Dams, Frozen Pipes February 13, 2015 Today s temperatures are expected to reach between 10 and 15 degrees Fahrenheit.
More informationIce Dams: Formations and Fixes
Ice Dams: Formations and Fixes 1st Edition 516.621.2900 info@jsheld.com jsheld.com As we approach the cooler change of seasons, we look forward to many things; the stunning change of foliage, football,
More informationChapter 10. Passive Cooling Contents
Chapter 10. Passive Cooling Contents 10.1 Introduction to Cooling 10.2 Historical and Indigenous Use of Passive Cooling 10.3 Passive Cooling Systems 10.4 Comfort Ventilation VS Night Flush Cooling 10.5
More informationWhy Are Attics Insulated With Open-Cell Spray Foam So Damp? Martin Holladay Editor, Green Building Advisor
Why Are Attics Insulated With Open-Cell Spray Foam So Damp? Martin Holladay Editor, Green Building Advisor Better Buildings By Design Burlington, Vermont February 7, 2018 Learning objectives Upon completion,
More informationWhat do I need to do before your crew comes over?
Ice Dams & Snow Removal Pricing Icicles hanging along the eaves of your house may look amazing, but Ice Damming can spell big trouble for your homes roof. $350 First Hour Of Work 2 roofers are included
More informationVenmar Ventilation inc. is North America s most important manufacturer of residential air quality equipment.
Venmar sets the standard for the ventilation industry! Venmar Ventilation inc. is North America s most important manufacturer of residential air quality equipment. With over twenty-five years of innovation,
More informationWilliam B. Rose University of Illinois at Urbana-Champaign
1 William B. Rose University of Illinois at Urbana-Champaign 2 Ralph Britton. Crawl spaces. 1947 3 From Ralph Britton, "Crawl Spaces: their effect on dwellings - an analysis of causes and results - suggested
More information17 Interior Climate Control
17 Interior Climate Control 17.1 Air is leaking through or around windows and/or exterior doors. Windows and doors shall be installed to minimize air leakage in accordance with the Alberta Building Code.
More informationAsurity 1. Property Inspection Report S Gurd Rd., Hastings, MI Inspection prepared for: Beretta Lenos Real Estate Agent: Stan Labinski -
Cover Page Property Inspection Report Inspection prepared for: Beretta Lenos Real Estate Agent: Stan Labinski - Date of Inspection: 3/28/2017 Time: 2:00 Age of Home: Built 1999 Size: 2015 Weather: 50 Overcast.
More informationGarage Ventilation Installation Instructions
Garage Ventilation Installation Instructions Parts List * Quantity Exterior Louver & Frame Kit 4 in. x 4 in. w/ Fasteners (Fastener shown as a) () Louver 4 in. x 8 in. w/ Fasteners (Fastener shown as a)
More informationInspection Checklist Mechanical Final
Property Owner Name: Property Address: Property Parcel Number: Inspectors Name: Review Date: Permits and Plans 1. Job address is posted in a visible location. (R319.1) 2. Permit and approved plans, and
More informationAir Distribution Systems in Conditioned Spaces i.e. Ducts in Unvented Attics
FLORIDA SOLAR ENERGY CENTER Creating Energy Independence Since 1975 Air Distribution Systems in Conditioned Spaces i.e. Ducts in Unvented Attics Neil Moyer Principal Research Engineer A Research Institute
More informationStart today and start saving!
Northeast Oklahoma REC s Do It Yourself Home Energy Audit Pllattiinum Levell Start today and start saving! First project (circle and initial when completed) Inadequate Ducts Objective: Check your ductwork
More informationFAIRA TRANSPARENCY REPORTS th St SE, Lake Stevens, WA June 14 th, 2017
608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 98258 June 14 th, 2017 We have
More informationRESNET HERS Rater Sample Test Questions 2
RESNET HERS Rater Sample Test Questions 2 1. Which of the following is the best device for removing standing water from a crawl space? A. Dehumidifier B. Sump pump C. Air-to-air heat exchanger D. Crawl-space
More informationSolar Whiz - Frequently Asked Questions
Solar Whiz - Frequently Asked Questions Can you tell me how much air each type of Solar Whiz is able to move compared to a Whirlybird working at capacity? The different Solar Whiz units are capable of
More informationMoisture Movement. By Ben Gromicko
By Ben Gromicko It is important to study moisture in a course that is about inspecting insulation, because wet insulation does not work well. Also, insulation is an important part of the building envelope
More informationSPS Home Inspections, LLC
Cover Page SPS Home Inspections, LLC Property Inspection Report 00000 Inspection prepared for: Mr. & Mrs. Homeowner Real Estate Agent: - Date of Inspection: 5/1/2012 Time: 11:00 am Age of Home: 39 Size:
More informationInstallation Instructions
FAVXXR6C2100-A01 Vent Damper and Control Installation Instructions FAMILIARIZE YOURSELF WITH THE INSTALLATION INSTRUCTIONS BEFORE STARTING ATTENTION INSTALLER: This product must be installed by a qualified
More informationREAD AND SAVE THESE INSTRUCTIONS
ROOF-MOUNT POWE ATTIC VENTILATOR Page 1 READ AND SAVE THESE INSTRUCTIONS WARNING TO UCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner
More informationInside Out Home Inspections
Cover Page Inside Out Home Inspections Property Inspection Report Inspection prepared for: John Doe & Jane Doe Date of Inspection: 5/10/2014 Inspector: Lucas Sargent PO Box 514, Tioga, PA 16946 Phone:
More information2013 Efficiency Requirements for Gas Furnaces
2013 Efficiency Requirements for Gas Furnaces By: John Hershey of J. Hershey Architecture The U.S. Department of Energy (DOE) published a direct final rule to establish amended energy conservation standards
More informationC e r t a i n Te e d D e s i g n e r S h i n g l e s
C e r t a i nte e d D e s i g n e r S h i n g l e s Shown in Tudor Brown Shown in Cottage Red meet Under crystal blue skies or silhouetted against the gathering storm, Hatteras designer shingles make a
More informationSEASONAL MAINTENANCE SCHEDULE
SEASONAL MAINTENANCE SCHEDULE Establishing and following a maintenance schedule is the best way to protect your investment, to ensure that by doing your maintenance you prevent the appearance of future
More informationGuide To Troubleshooting INEFFICIENT COOLING FANS
Guide To Troubleshooting INEFFICIENT COOLING FANS TABLE OF CONTENTS Introduction Enclosure Cooling Basics Key Attributes of Enclosure Cooling Symptoms of Poor Enclosure Cooling Typical Cooling Fan Problems
More informationExtra Mile Inspection, Inc.
Cover Page Property Inspection Report Inspection prepared for: Jerry and Lynne Richardson Real Estate Agent: Polly Richardson - BHKR Lake Forest Date of Inspection: 3/13/2017 Time: 12 pm Age of Home: built
More informationTennessee Valley Property Inspections
Cover Page Tennessee Valley Property Inspections Property Inspection Report Inspection prepared for: Billy Bob & Eula May Jones Date of Inspection: 1/9/2017 Time: 0900 Size: 4900sf Weather: 30 degrees.
More informationEnvironmental Assessment From an Indoor Air Quality (IAQ) Perspective At 3 Valley Road New Idaho NJ 94T18
Environmental Assessment From an Indoor Air Quality (IAQ) Perspective At 3 Valley Road New Idaho NJ 94T18 Performed for: Mr. and Mrs. Bird Work performed on premises Last week By Sal La Duca Indoor Environmentalist
More informationAdvanced Property Inspections
Cover Page Home Inspection Report Inspector: Darren Taylor License #672-106 12421-32nd Ave, Pleasant Prairie, WI 53158 Phone: 262-458-4176 Email: darren.advpi@gmail.com kenoshahomeinspection.com The following
More informationFeaturing The Weather Stopper Roof Protection Program!
Featuring The Weather Stopper Roof Protection Program! Get Protection On Your Entire GAF Roofing System! Manufacturing Defect Coverage For Shingles* Overall coverage period 100%) coverage period Covers
More informationPART 5: HVAC & DHW SYSTEMS
PART 5: HVAC & DHW SYSTEMS Building Science Review Building Science Review: HVAC & DHW Systems This document will help you: Correctly answer all parts of the HVAC Systems section in the Home Energy Score
More informationAUTOMATIC MAKE-UP AIR DAMPER WITH TRANSFORMER READ AND SAVE THESE INSTRUCTIONS
AUTOMATIC MAKE-UP AIR DAMPER WITH READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY Page 1 WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Installation
More informationSBEC Residential Energy Efficiency 2019 Rebate Programs for Existing Homes
SBEC Residential Energy Efficiency 2019 Rebate Programs for Existing Homes There are numerous improvements that you can make to your home to help reduce its energy consumption. SBEC wants to encourage
More information4. A 2 X4 knee wall, if insulated, should be to what R value? 5. The clearance between insulation and a furnace vent should be:
Weatherization -Basic Final Exam NAME 1. Infiltration is: a. Heat movement through solid materials b. The uncontrolled air flow through holes and cracks c. Heat flow through dead air spaces d. Heat transfer
More informationBasic Ventilation Considerations for Livestock or Poultry Housing
PNW 307 Reprinted June 1993 Basic Ventilation Considerations for Livestock or Poultry Housing J. A. Moore Most producers would agree that all buildings that house livestock and poultry need ventilation.
More informationNortheast Oklahoma REC s Do It Yourself Home Energy Audit Silver Level
Northeast Oklahoma REC s Do It Yourself Home Energy Audit Silver Level Start today and start saving! First project (circle and initial when completed) Hot Water Tank Blanket Objective: Install a blanket
More informationDOC // ROOF OVER DECK IDEAS DOWNLOAD
21 January, 2018 DOC // ROOF OVER DECK IDEAS DOWNLOAD Document Filetype: PDF 329.97 KB 0 DOC // ROOF OVER DECK IDEAS DOWNLOAD See 45 great manufactured home porch designs. You cannot penetrate the eaves
More informationSupplement A- Improving Forced Air Heating Systems
Supplement A Improving Forced Air Heating Systems The Challenge Recent research and testing of new homes in the Pacific Northwest and across the United States shows the importance of a properly installed
More informationFAIRA TRANSPARENCY REPORTS SE Woody Creek Ln, Snoqualmie, WA October 12, 2017
608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 98065 Thank you for your interest in this Faira Certified home. October 12, 2017 We have
More informationThings To Know About Tankless Water Heaters II
Fall 2012 Things To Know About Tankless Water Heaters II Inside... Sizing Tables... Page 2 Two-pound Systems... Page 3 Two-pound Line Table... Page 3 Venting Specifications... Page 3 In the last Think
More informationThe Ultimate Home Maintenance Schedule
The Ultimate Home Maintenance Schedule On-Going Quarterly Maintenance Schedule Check interior and exterior faucets for leaks. Clean aerators. Replace washers if Clean with baking soda. Pour water down
More informationFAIRA TRANSPARENCY REPORTS Waverly Dr, Snohomish, WA May 10 th, 2017
608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 98296 May 10 th, 2017 We have coordinated
More informationMONTH-BY-MONTH GUIDE TO HVAC MAINTENANCE
Just like any critical piece of equipment, your heating and cooling systems require regular HVAC maintenance to keep them running properly. Home and business owners should stay on top of maintenance tasks
More informationOperating Guidelines for Your Roof and Gutter Ice Dam Prevention System
1. Your heat cable system is designed to be preventative. This means it needs to be energized several hours prior to snow fall and should remain on while there is substantial snow on the roof. We will
More informationFrequently Asked Questions
Customer Service Frequently Asked Questions Updated January 1, 2006 1. How long has Austin Air Systems been in business? Since 1990. 2. What is the difference between the AllergyMachine and the HealthMate?
More informationBISHOP HOME INSPECTIONS, LLC. Phone (269) / Fax (269) / Website: bishophomeinspection.
BISHOP HOME INSPECTIONS, LLC. Phone (269) 686-6485 / Fax (269) 686-7798 email: bishophomeinspection@charter.net / Website: bishophomeinspection.com Inspection address: 123 rth Street Client name: Gerald
More informationFeaturing The Weather Stopper Roof Protection Program!
Featuring The Weather Stopper Roof Protection Program! Get Protection On Your Entire GAF Roofing System!* TYPICAL Manufacturing Defect Coverage The Weather Stopper 3-Part Roof Protection Program Eligibility
More informationabout your house Choosing a Dehumidifier
about your house CE 27 Moisture in house air can be a problem when there is either too little or too much. Air that is too dry can cause discomfort, dried and itchy skin and nasal passages, cracked or
More informationLand Use and Environmental Service Agency (Code Enforcement) Mechanical Q&A 2007
General: 1) (Q) May the gas be turned on temporarily to the gas piping system without the installation of the appliance? (A) NO! 2) (Q) Are traps required on all condensate drains from equipment? (A) Only
More informationREQUIRED CONTRACT DETAIL. $2, , Direct DC Fuel Cell Power System, Stationary PACE Power output < 40 kw
Residential Eligible Improvements and Guidelines FLORIDA To qualify for Ygrene funding, all project improvements must meet or exceed applicable local, state and federal codes and standards, and be installed
More informationSUMMARY 1234 Main St.Edmonton AB T5T3E9 Buyer Name 07/05/2018 9:00AM
SUMMARY 1234 Main St.Edmonton AB T5T3E9 Buyer Name 07/05/2018 9:00AM Banti Shaw InspecUs InspecUs 7808623549 bantishaw@inspecus.ca This Summary outlines potentially significant issues from a cost, safety
More informationModel 8120 and 8126 Safety & Installation Instructions
Ventilation Controller Model 8120 and 8126 Safety & Installation Instructions FAMILIARIZE YOURSELF WITH THE INSTALLATION INSTRUCTIONS BEFORE STARTING DANGER ATTENTION INSTALLER: To prevent serious injury
More informationHearth and Homes Inspections, llc
Cover Page Property Inspection Report 44092 Inspection prepared for: Ember Griffith Real Estate Agent: Samantha Elly - Keller Williams Date of Inspection: 3/4/2017 Time: 10:00 AM Age of Home: 63 Years
More informationBuilding Science Basics
Building Science Basics Introduction to Building Science Basics Since a home is the most significant purchase most people make, and good health is priceless, knowing how to protect both is important. On
More informationHome Inspection Report
Home Inspection Report Mr. Mrs. Property Address: 123 Main Street Any Town GA 30000 Champ Home Inspections Inc. Jim Champ 770-516-8882 Office 770-367-4123 Cell 678-494-0171 Fax www.champhomeinspections.com
More informationFAIRA TRANSPARENCY REPORTS th Dr NE, Lake Stevens, WA April 4th, 2017
608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 98258 April 4th, 2017 We have coordinated
More informationb.) Technical Information:
Section VI- Strategies a.) Summary: It is important for new construction designers to consider the heating, ventilation, and air conditioning needs within a building. There are many different systems,
More informationAmerica s Best Home Products, L.C. 855-GF14FAN. CoolMyGarage.com
Garage Complete Packages, Garage Ventilation Fans, Garage Flooring, Garage Door Insulation, Garage Overhead Storage, Garage Storage Cabinets, Garage Vacuums, Garage & Patio Heaters, Large Shop or Commercial
More informationRater Provider Monthly Webinar REM Rate Modeling Tips March 23rd 2013
Rater Provider Monthly Webinar REM Rate Modeling Tips March 23rd 2013 Emelie Cuppernell and Ethan MacCormick Using Your Toolbar To expand or minimize the view, click here To raise your hand, click here
More informationThe NWX Colonial Revival Style
The NWX Colonial Revival Style History and Character The NorthWest Crossing Colonial Revival style home takes it cues from the rebirth of interest in the early English and Dutch houses of the Atlantic