Models: Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel. Blower Assembly

Size: px
Start display at page:

Download "Models: Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel. Blower Assembly"

Transcription

1 REPLACEMENT PART MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: WA0, WA7 General Notes! Revised and/or additional pages may be issued from time to time.! A complete and current manual consists of pages shown in the following contents section. Contents Cabinet Components Page " Exploded View... " Usage List... Functional Components " Exploded View... " Usage List... 4 Important! Contact the installing and/or local Bard distributor for all parts requirements. Make sure you have the complete model and serial number available from the unit rating plates. Control Panel Blower Assembly " Exploded View... " Usage List... " Exploded View... 7 " Usage List... 7 BARD MANUFACTURING COMPANY Bryan, Ohio 40 ince 94...Moving ahead, just as planned. Manual: 0-4A upersedes: 0-4 File: Tab Date: Manual 0-4 Page

2 CABINET COMPONENT EP-0 Manual 0-4 Page

3 CABINET COMPONENT Drawing N o. Part No * * -09-* * Lower Base Fan hroud Right ide Left ide Control Panel Cover (Outer ) Condenser Partition Blower Partition To p Outlet Airframe Assembly Back Filter Bracket -04 Control Panel Cover (Inner) -7 Control Panel Cover (Inner) * ide Grille 8-09-* Condenser Grille BFAD- Fresh Air Damper Assembly 7-0-* ervice Door * Upper Front Left ide upport * Right ide Cover Plate (Outer ) -078 Drain Pan Evaporator upport -4 Air Baffle 4 Control Panel ee Control Panel Assembly Assembly Drawing and Parts List -40 Bottom Mounting Breacket Heat hield 7-8-* Disconnect Access Door Rill Plate 9-49-* Top Rain Flashing WA0-A,B,D WA0-C WA0-F WA7-A,B,D,E WA7-C WA7-F NOTE: Eterior cabinet parts are manufactured with various paint color options. To insure that you receive the proper paint color, you must include the complete model and serial number of the unit for which cabinet parts are being ordered. Manual 0-4 Page

4 FUNCTIONAL COMPONENT EP- Manual 0-4 Page

5 FUNCTIONAL COMPONENT Drawing N o. Part No Blower Assembly Blower Assembly WA0-A WA0-B WA0-C WA0-D WA0-F WA7-A WA7-B WA7-C WA7-D WA7-E WA7-F Fan Motor Mount 4-04 Fan Blade Condenser Motor Condenser Motor 0-0 Condenser Coil Cooling Capillary Assembly Cooling Capillary Assembly Evaporator Coil Air Filter " Throw-Away Air Filter " Washable Air Filter " Pleated 7-0 /4 Turn Fasterner 7-04 /4 Turn Retainer 7-0 /4 Turn Receptacle N High Pressure witch (Flare) N Low Pressure witch (Flare) N C MA- Low Ambient Control (Flare) N Not hown Optional Manual 0-4 Page 4

6 CONTROL PANEL EP-9 Manual 0-4 Page

7 CONTROL PANEL Drawing N o. Part No Low Voltage Terminal trip Terminal Block Pole Terminal Block Pole Phenolic Insulator Phenolic Insulator Blower Control Blower Relay Transformer Transformer Contactor Contactor Capacitor Capacitor Capacitor Capacitor Outdoor Motor Capacitor WA0-A WA0-B WA0-C WA0-D WA0-F WA7-A WA7-B WA7-C WA7-D WA7-E WA7-F 7 - Wire hield Ground Termina l Pin Connecto r C ompressor Control Module (Optional ) TDR (Optional) Phase Monitor Terminal Block (Optional ) 8-00 tart Device (PTRC) (Optional ) 80-0 Alarm Relay (Optional ) 7-7 Control Panel To p 7- Control Panel N 8-08 Circuit Breaker A Pole (Opt) N 8-04 Circuit Breaker 0A Pole (Opt) N 8-0 Circuit Breaker A Pole (Opt) N 8-07 Toggle Disconnect (Optional ) N N N N Wiring Diagram Wiring Diagram Wiring Diagram Wiring Diagram N Not hown Circuit breakers listed are for units without electric heat, "0Z" models. ee Heater Replacement Parts Manual for units with electric heat. Manual 0-4 Page

8 BLOWER AEMBLY Drawing N o. Part No Blower Housing Diffuser Blower Motor (0/08) Blower Motor (40) Capacitor Motor Mount 4-0 Grommets Back Brace Front Brace Wheel (CW) 0-09 Wheel (CCW) EP-4 Manual 0-4 Page 7

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL-MOUNTED PACKAGE AIR CONDITIONER Models: W7A W8A WA General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual consists of

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL-MOUNTED PACKAGED AIR CONDITIONER HA-A HL-A Models: H6A-A H6L-A Description Page Cabinet Components HA-A, H6A-A Exploded View... Usage List HA-A... Usage List H6A-A... Cabinet

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGED AIR CONDITIONER W0AA-A W0AA-B W0AA-C W0AA-D W0AA-F WAA-A WAA-B WAA-C WAA-D WAA-E WAA-F Models: W0AADA W0AADB W0AADC WAADA WAADB WAADC Contents Description

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL-MOUNTED VARIABLE CAPACITY ENVIRONMENTAL CONTROL UNIT WRV-S WRV-T Models: WLV-S WLV-T Contents Description Page Cabinet Components Right (Extreme Duty Door) Exploded View...

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL-MOUNTED SASO CERTIFIED AIR CONDITIONER Models: KA-N KA-N K0A-N General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL W0HA-A W0HA-B W0HA-C WALL MUNTED PACKAGED HEAT PUMP WHA-A WHA-B WHA-C Models: W0HADA W0HADB W0HADC WHADA WHADB WHADC Contents Description Page Cabinet Components Exploded View...

More information

THE WALL-MOUNT AIR CONDITIONERS (50HZ)

THE WALL-MOUNT AIR CONDITIONERS (50HZ) THE WALL-MOUNT AIR CONDITIONER (50HZ) Models W24A2 to W70A2 Right ide Control Panel Models W24L2 to W70L2 Left ide Control Panel 2,600 Btuh (6.33 KW) 62,000 Btuh (8.6 KW) For Export Only The Bard Wall-Mount

More information

MARVAIR COMPAC AIR CONDITIONERS MODELS AVP72AC AND AVPA72AC EXPLODED VIEW PARTS ID EXTERIOR SHEET METAL (OUTER PANELS)

MARVAIR COMPAC AIR CONDITIONERS MODELS AVP72AC AND AVPA72AC EXPLODED VIEW PARTS ID EXTERIOR SHEET METAL (OUTER PANELS) EXTERIOR SHEET METAL (OUTER PANELS) 1 COMPAC AVP72/AVPA72 PARTS LIST, 03/09 EXTERIOR SHEET METAL (OUTER PANELS) AVP72AC AVPA72AC 1 Panel, Back (Galvanized) M/04443SP 2 Right Side Panel, ComPac II M/04465XXSP

More information

INSTALLATION INSTRUCTIONS ELECTRIC HEAT PACKAGES

INSTALLATION INSTRUCTIONS ELECTRIC HEAT PACKAGES INSTALLATION INSTRUCTIONS ELECTRIC HEAT PACKAGES Models: EHWA3S-B06 EHWA4S-A10 EHWA4S-A20 EHWA5S-A08 EHWA5S-A15 EHWA5S-B06 EHWA5S-B15 EHWA5S-C09 EHWA4S-A05 EHWA4S-A15 EHWA5S-A05 EHWA5S-A10 EHWA5S-A20 EHWA5S-B09

More information

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONER - 9. EER, (HZ) Model W7A2 Right-ide Control Panel Model W7L2 Left-ide Control Panel Ton (, Btuh) For Export Only The Bard Wall-Mount Air Conditioner is a self contained energy

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS Model: WA121 Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. Manual : 2100-234 G Supersedes: 2100-234

More information

INSTALLATION INSTRUCTIONS ELECTRIC HEAT PACKAGES EHWA02-AXD EHWA02-AXH EHWA03-AXH EHWA03-AXK EHWA05-AXH EHWA05-AXK

INSTALLATION INSTRUCTIONS ELECTRIC HEAT PACKAGES EHWA02-AXD EHWA02-AXH EHWA03-AXH EHWA03-AXK EHWA05-AXH EHWA05-AXK INSTALLATION INSTRUCTIONS ELECTRIC HEAT PACKAGES Models: EHWA02-AXD EHWA02-AXH EHWA03-AXH EHWA03-AXK EHWA05-AXH EHWA05-AXK For 2 thru 5 Ton WA Series Wall Mounted Air Conditioners BARD MANUFACTURING COMPANY

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS MODELS WA3 WA43 WA44 WA49 WA Bard Manufacturing Company Bryan, Ohio 4350 Since 94...Moving ahead just as planned. Manual : 0-39 Supersedes:

More information

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONER -. EER, (HZ) Models W7A to W7A Right-ide Control Panel Models W7L to W7L Left-ide Control Panel. to Ton (, to, Btuh) The Bard Wall-Mount Air Conditioner is a self contained

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS MODELS WA3 WA42 WA42 WA49 WA2 Bard Manufacturing Company Bryan, Ohio 4350 Since 94...Moving ahead just as planned. Manual : 20-2J Supersedes:

More information

MARVAIR MODPAC TM AIR CONDITIONERS MODELS AVPA EXPLODED VIEW PARTS ID

MARVAIR MODPAC TM AIR CONDITIONERS MODELS AVPA EXPLODED VIEW PARTS ID MODELS AVPA -8-0 EXPLODED VIEW PARTS ID EXTERIOR SHEET METAL (OUTER PANELS) 0 8 5 AVAP AVPA8 AVPA0 Panel, Back (Galvanized) M/0-SP Door, Front Top M/0-XXSP Door, Front Bottom M/080-XXSP Fresh Air Hood

More information

Installation Instructions

Installation Instructions Installation Instructions Wall Mounted Packaged Air Conditioner Models: WA8, WA24 MIS-656 Bard Manufacturing Company Bryan, Ohio 43506 Since 94...Moving ahead, just as planned. Manual No.: 20-200K Supersedes:

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS CMH-28 Compressor Cutout Thermostat Kit For Use with W18HA, W24HA, W30HA and W36HA Wall-Mount Heat Pumps The CMH-28 is a field-installable compressor cutout outdoor thermostat

More information

MARVAIR COMPAC AIR CONDITIONERS MODELS AVP EXPLODED VIEW PARTS ID

MARVAIR COMPAC AIR CONDITIONERS MODELS AVP EXPLODED VIEW PARTS ID EXTERIOR SHEET METAL (OUTER PANELS) 1 Panel, Back (Galvanized) M/04996-SP 2 Door, Front Top M/01294-XXSP 3 4 Door, Front Bottom w/slots 1,2 (shown) Door, Front Bottom w/ext. Fresh Air Hood (not shown)

More information

REPLACEMENT PARTS LIST

REPLACEMENT PARTS LIST REPLACEMENT PARTS LIST PACKAGED AC UNIT WITH OPTIONAL ELECTRIC HEAT P7TQ SERIES 6-, 7.5-, AND 10-TON IMPORTANT This document is primarily intended to assist qualified individuals experienced in the proper

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS W12A2-A W12A1-K

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS W12A2-A W12A1-K INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS Model: W12A2-A W12A1-K Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. Manual: 2100-509E Supersedes:

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS MOTORIZED FRESH AIR DAMPER Models: WMFADP2 WMFADP3 WMFADP5 Bard Manufacturing Company, Inc. Bryan, Ohio 43506 www.bardhvac.com Manual: 2100-650 Supersedes: NEW Date: 3-18-16 Page

More information

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features THE WALL-MOUNT ONE TON AIR CONDITIONER W2A,800 Btuh 9.00 EER Right Side Control Panel 60Hz GREEN REFRIGERANT R-A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating

More information

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONER -. EER, (HZ) Models WAA to W72AA Right-ide Control Panel Models WLA to W72LA Left-ide Control Panel. to Ton (7, to 7, Btuh) Green Refrigerant R-A The Bard Wall-Mount Air

More information

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB BARD MANUFACTURING COMPANY, INC. W18AA-W72AB Series Right-Side Access Air Conditioner W18LA-W72LB Series Left-Side Access Air Conditioner Engineering Specification Guide 1.0 GENERAL Furnish and install

More information

REPLACEMENT PARTS LIST

REPLACEMENT PARTS LIST REPLACEMENT PARTS LIST PACKAGED GAS HEATING/ELECTRIC COOLING R7TQ SERIES 6-, 7.5-, AND 10-TON, 81% STEADY STATE EFFICIENCY IMPORTANT This document is primarily intended to assist qualified individuals

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See  for the current revision. URM- Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42801-urm-.pdf for the current revision. Package Gas-Electric Table of Contents Model Explanation...................................................................................................................

More information

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit D36A/L 1-tage Right & Left-Hand Control Panel Green Refrigerant R-410A The Bard DUAL-TEC Wall Mount Air Conditioners

More information

Shelleybasic. Parts List For Replacements Parts Only Shelleybasic Is No Longer In Production As Of April 2016

Shelleybasic. Parts List For Replacements Parts Only Shelleybasic Is No Longer In Production As Of April 2016 Shelleybasic Parts List For Replacements Parts Only Shelleybasic Is No Longer In Production As Of April 0 Contents Condensing Unit Assembly, / HP, Ra... Condensing Unit Assembly, / HP, R0a... Condensing

More information

INSTALLATION INSTRUCTIONS ELECTRIC HEAT PACKAGES

INSTALLATION INSTRUCTIONS ELECTRIC HEAT PACKAGES INSTALLATION INSTRUCTIONS ELECTRIC HEAT PACKAGES Models: EHWH02A-A04 EHW02A-A08 EHWA24A-A04 EHW24H-A04 EHW24H-A08 EHWH02A-A08 EHWA02-A05 EHWA02A-A08 EHWH24-B06 EHW24H-B06 EHWH24B-C06 EHWA02A-A10 EHWH30-A05

More information

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features THE WALL-MOUNT ONE TON AIR CONDITIONER W2AAA 2,000 Btuh.00 EER Right Side Control Panel 60Hz Green Refrigerant R-4A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating

More information

INSTALLATION INSTRUCTIONS ELECTRIC HEAT PACKAGES

INSTALLATION INSTRUCTIONS ELECTRIC HEAT PACKAGES INSTALLATION INSTRUCTIONS ELECTRIC HEAT PACKAGES Models: EHW05A-B15B EHW05A-B18B EHW05A-C09 EHW05A-C15 EHW05H-B18B EHW60A-B09B EHW70A-B09B EHW70A-B18B EHWA05-A05B EHWA05-A10B EHWA05-A15B EHWA05-A20B EHWA05-B09B

More information

THE MULTI-TEC WALL-MOUNT AIR CONDITIONERS 10 EER (50 HZ) WITH LOGIC BOARD

THE MULTI-TEC WALL-MOUNT AIR CONDITIONERS 10 EER (50 HZ) WITH LOGIC BOARD The MULTI-TEC Wall-Mount Air Conditioner utilizes PLC (Programmable Logic Control) technology to allow multiple units to operate connected to a single LC6000 controller. When installed with an optional

More information

MARVAIR CLASSIC HEAT PUMPS MODELS AVP HP EXPLODED VIEW PARTS ID

MARVAIR CLASSIC HEAT PUMPS MODELS AVP HP EXPLODED VIEW PARTS ID EXTERIOR SHEET METAL (OUTER PANELS) 1 Panel, Back (Galvanized) M/05039SP M/05034SP M/05034SP 2 Door, Front Top 02976SP 02937SP 02937SP 3 4 Door, Front Bottom w/slots, Damper 1,2 (shown) M/06753-XXSP M/06752-XXSP

More information

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017 Replacement s List 055208000 Revision E 08/207 McQuay Incremental MQS 007-05 Vintages A 02-05 Vintage B Last Manufactured: 993 To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

THE WALL-MOUNT TM SIX TON AIR CONDITIONER

THE WALL-MOUNT TM SIX TON AIR CONDITIONER The Bard Wall-Mount Six Ton Air Conditioner is a self contained energy efficient system, which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or

More information

MARVAIR MODPAC II AIR CONDITIONERS MODELS AVP EXPLODED VIEW PARTS ID

MARVAIR MODPAC II AIR CONDITIONERS MODELS AVP EXPLODED VIEW PARTS ID EXTERIOR SHEET METAL (OUTER PANELS) 1 Panel, Back (Galvanized) M/05039SP M/05034SP M/05034SP 2 Door, Front Top 02976SP 02937SP 02937SP 3 4 Door, Front Bottom w/slots, Damper 1,2 (shown) M/06753-XXSP M/06752-XXSP

More information

Green Refrigerant. MULTI-TEC WALL-MOUNT Features All Models. Standard Features All Models

Green Refrigerant. MULTI-TEC WALL-MOUNT Features All Models. Standard Features All Models The MULTI-TEC Wall-Mount Air Conditioner utilizes PLC (Programmable Logic Control) technology to allow multiple units to operate connected to a single LC00 controller. When installed with an optional 0%

More information

SCE170 SERVICE PARTS

SCE170 SERVICE PARTS This is the parts list for the SCE170. When looking up part numbers, always check the complete model and serial numbers to be certain of ordering the correct parts. The SCE170 has been manufactured in

More information

Daikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015

Daikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015 Replacement Parts List No. 700027600 Revision D 02/2015 Daikin McQuay Packaged Terminal Air Conditioner PGAN 007, 009, 012, 015 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit D35A/L 1-tage Right & Left-Hand Control Panel The Bard DUAL-TEC Wall Mount Air Conditioners with -48VDC Blower

More information

THE WALL-MOUNT Quiet Climate A/C 10.0 EER

THE WALL-MOUNT Quiet Climate A/C 10.0 EER THE WALL-MOUNT Quiet Climate A/C. EER Models WA, W9A, WA to Ton (, to, Btuh) Right Side Control Panel Hz GREEN REFRIGERANT R-A The Bard Wall-Mount Air Conditioner is a self contained energy efficient system,

More information

McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995

McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995 Replacement Parts List No. 055236000 Revision B 06/2015 McQuay Ceiling Concealed Horizontal Water Source Heat Pump CCH, CCG, CCW 048, 060 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts

More information

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11 SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. Manual No.: 2100-479 Supersedes: NEW File: Volume

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A WALL-MOUNT HEAT PUMPS - (0HZ) Models: JH to J0H 0Hz Heating Capacities:,000 to,000 Capacities:,00 to,000 Solair Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling system, which

More information

Climate Control Singer. Incremental Comfort Systems. KS, EKS Vintage B. Last Manufactured: 1982

Climate Control Singer. Incremental Comfort Systems. KS, EKS Vintage B. Last Manufactured: 1982 Replacement s List No. 055202900 Revision A 11/1999 Climate Control Singer Incremental Comfort Systems KS, EKS 07-15 Vintage B Last Manufactured: 1982 To find your Daikin Applied parts distributor, call

More information

XTREME ICE MAKER (1230 SERIES)

XTREME ICE MAKER (1230 SERIES) XTREME ICE MAKER (0 SERIES) MODEL NO. 00 00 00 00 00 00 0 XTREME ICE (0) of Manual Part No. 00IPL 00 IMI Cornelius Co., 00 XTREME ICE MAKER (0 SERIES) FIGURE. GENERAL ASSEMBLY (AIR CONDENSER SHOWN) 00

More information

Spare Parts Catalogue MV1006

Spare Parts Catalogue MV1006 Spare Parts Catalogue MV1006 1 - UNIT PANELS - AIR COOLED 2 - UNIT PANELS - WATER COOLED 3 - REFRIGERANT SYSTEM - AIR COOLED - UP TO S.N. 00462 4 - REFRIGERANT SYSTEM - AIR COOLED - FROM S.N. 00463 TO

More information

Replacement Parts List

Replacement Parts List Replacement Parts List SINGLE PACKAGE AIR CONDITIONER GENERATION 4 42 CABINET DS-07 COMPRESSORS 1 1 Compressor, H20J403DBLA 015-03652-001 2 - - 1 1 Compressor, H20J403DBEA 015-03682-001-2 - 1 1 Compressor,

More information

PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A)

PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A) www.source1parts.com HVAC SERVICE PARTS PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A) Supersedes:035-21137-001 Rev. E (1107) 035-21137-001 Rev. F (0611) 1 of 8 CONDENSER ROOF (SEE

More information

Replacement Parts List

Replacement Parts List Replacement Parts List SINGLE PACKAGE AIR CONDITIONER GENERATION 4 42 CABINET Note: This is a non-comprehensive parts list intended for stocking purposes for first production (style A) units based on current

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH381 WH431 WH491

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH381 WH431 WH491 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS Models WH3 WH43 WH49 Bard Manufacturing Company, Inc. Bryan, Ohio 436 Since 94...Moving ahead just as planned. Manual : 20-342I Supersedes: 20-342H

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See  for the current revision. - Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800--.pdf for the current revision. Package Air onditioners Table of ontents Model Explanation...................................................................................................................

More information

UNIVERSAL 750 PRE-MIX DISPENSER

UNIVERSAL 750 PRE-MIX DISPENSER Anoka, MN. 0 - Telephone -00--00 Facsimile -00--0 MODEL NO. xxx xxx Universal 0 of Control Code A Manual Part No. 00 -- Revised: -- ªIMI Cornelius Co., - Anoka, MN. 0 - Telephone -00--00 Facsimile -00--0

More information

RP8.1Y (ERRATA 1) (202) 2 of 8

RP8.1Y (ERRATA 1) (202) 2 of 8 530.18-RP8.1Y (ERRATA 1) (202) 2 of 8 ELECTRICAL (Cont.) FIG ITEM DESCRIPTION D6CG048N06006A D6CG048N06025A D6CG048N06046A D6CG048N06058A 3-BURNER 3-BURNER 3-BURNER 3-BURNER * 15 CONNECTOR, CAP (9-CIRCUIT)

More information

Repair Parts List REFRIGERATOR MODEL NUMBER GC20B8C3EB. When requesting service or ordering parts, always provide the following information:

Repair Parts List REFRIGERATOR MODEL NUMBER GC20B8C3EB. When requesting service or ordering parts, always provide the following information: Repair Parts List REFRIGERATOR MODEL NUMBER GC20B8C3EB When requesting service or ordering parts, always provide the following information: - Product Type - Part Number - Model Number - Part Description

More information

Daikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017

Daikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017 Replacement Parts List No. 700028400 Revision A 07/207 Daikin McQuay Incremental PKEI, PKES, PKHS 07-09 Design 2 To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016 Replacement Parts List No. 057117300 Revision D 08/2016 AAF Water Source Heat Pump Ceiling Mounted CCW 019-060 Vintage E Last Manufactured: 1999 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

DDYZ SERIES - 13 SEER SINGLE PACKAGED GAS/ELECTRIC AIR CONDITIONER (R-410A, STYLE A,B)

DDYZ SERIES - 13 SEER SINGLE PACKAGED GAS/ELECTRIC AIR CONDITIONER (R-410A, STYLE A,B) www.source1parts.com HVAC SERVICE PARTS DDYZ SERIES - 13 SEER SINGLE PACKAGED GAS/ELECTRIC AIR CONDITIONER (R-410A, STYLE A,B) Supersedes:035-23383-001 Rev. A (1211) 035-23383-001 Rev. B (0112) 1 of 14

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH421 WH483 WH602

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH421 WH483 WH602 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS MODELS: WH42 WH43 WH2 BARD MANUFACTURING COMPANY Bryan, Ohio 4350 Since 94...Moving ahead, just as planned. Manual: 20-399 Supersedes: File: Volume

More information

Installation and Maintenance Manual Please retain this manual for future reference.

Installation and Maintenance Manual Please retain this manual for future reference. 342 N. Co. Rd. 400 East Valparaiso, IN 46383 219-464-8818 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. Electric Construction Heaters

More information

For more Parts Information:

For more Parts Information: For more Parts Information: https://manitowocfsg.sysonline.com/default.aspx TABLE OF CONTENTS Manitowoc Foodservice [Updated: Sep. 30, 2013] Manitowoc - Ice & Related Parts Catalog Ice Machine Q Series

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGED AIR CONDITIONER Models: W7A2-A WA2-A W24A2-A W24A2-B W24A2-C W24A2-D W24A2-F WA2-A WA2-B WA2-C WA2-D WA2-F WA2-A WA2-B WA2-C WA2-D WA2-E WA2-F W42A2-A W42A2-B

More information

Parts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com

Parts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com Parts List Modular Crescent Cuber Models KM-901MAJ KM-901MWJ KM-901MRJ/3 hoshizakiamerica.com Number: 71391 Issued: 10-23-2017 Revised: 6-8-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts...

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP Models WH84 WH242 Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 94...Moving ahead just as planned. Manual : 200-423C Supersedes: 200-423B

More information

THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS

THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS Models: SH to SH Up to.5 EER Heating Capacities: 2, to, BTUH Cooling Capacities: 2, to 55, BTUH Green Refrigerant R-A The Bard Wall-Mount Heat Pump is a self-contained

More information

WALL-MOUNT HEAT PUMPS - (60HZ)

WALL-MOUNT HEAT PUMPS - (60HZ) WALL-MOUNT HEAT PUMPS - (0HZ) Models: JH to J0H 0Hz Heating Capacities:,000 to 5,000 Cooling Capacities:,00 to 5,000 Solair Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling

More information

For more Parts Information: https://manitowocfsg.sysonline.com/default.aspx

For more Parts Information: https://manitowocfsg.sysonline.com/default.aspx For more Parts Information: https://manitowocfsg.sysonline.com/default.aspx TABLE OF CONTENTS Manitowoc Foodservice [Updated: Sep. 30, 2013] Manitowoc - Ice & Related Parts Catalog Ice Machine Q Series

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. Parts List Form No. 92-42800- This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Package ir Conditioners Table of Contents

More information

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994 Replacement Parts List No. 05708900 Revision C 06/205 McQuay Incremental Packaged Terminal Air Conditioner MQT 06-4 Vintage B Last Manufactured: 994 To find your Daikin Applied parts distributor, call

More information

The Wall-Mount Variable Capacity Environmental Control Units. Green Refrigerant

The Wall-Mount Variable Capacity Environmental Control Units. Green Refrigerant The Wall-Mount Variable Environmental Control Units Bard is an ISO 00:200 Certified Manufacturer, 5 and -Ton Variable ECU Dual /50 Hz Frequency Cooling Op Range -40F to +F ODT The Bard Variable ECU design

More information

AIR-CONDITIONER SERVICE MANUAL

AIR-CONDITIONER SERVICE MANUAL FILE NO. A90-9608 SERVICE MANUAL AIR-CONDITIONER S SPLIT BUILT-IN DUCT TYPE RAV-362B-PE/ RAV-462B-PE/ SPLIT CEILING TYPE RAV-362C-PE/ RAV-462C-PE/ SPLIT CASSETTE TYPE RAV-362U-PE/ RAV-462U-PE/ PRINTED

More information

Room Air Conditioner Service and Parts Manual

Room Air Conditioner Service and Parts Manual Cool Dry Temp Mode Room Air Conditioner Service and Parts Manual F Fan Speed hr Timer 0n 0ff Money Saver Fan Only Auto Swing Power CP06 CP08 93011401_01 CONTENTS 1. PREFACE 1.1 SAFETY PRECAUTIONS...2 1.2

More information

Spare Parts Reporting System

Spare Parts Reporting System 2008 50ZP 230-3-60 048 50ZP048 511S AIR CONDITIONING PARTS 024-8403-165B LOW PRESSURE SWITCH 1 024-8403-168B HIGH PRESSURE SWITCH 1 EC39DM061E VALVE BODY, REFRIGERANT ACCESS 4 GB20HN001S COMPRESSOR 1 ELECTRICAL

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP Models WH184 WH242 Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. Manual : 2100-423A Supersedes: 2100-423

More information

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991 Replacement Parts List No. 055203500 Revision G 05/206 McQuay Climate Control Singer Incremental ES, RS, S 06, 09,, 4 Vintage B Last Manufactured: 99 To find your Daikin Applied parts distributor, call

More information

CME650 SERVICE PARTS

CME650 SERVICE PARTS This section contains the parts illustrations and parts lists for the CME650. CM650 ice machines are manufactured in both 60 cycle and 50 cycle. When ordering electrical parts, be certain to match the

More information

INSTALLATION INSTRUCTIONS GPM SERIES LOOP PUMP MODULES

INSTALLATION INSTRUCTIONS GPM SERIES LOOP PUMP MODULES INSTALLATION INSTRUCTIONS GPM SERIES LOOP PUMP MODULES Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving, ahead just as planned. Manual: 2100-212A Supersedes: 2100-212 File: Tab 8

More information

Heat Pump Defrost Board Replacement Kit

Heat Pump Defrost Board Replacement Kit Bard Manufacturing Company, Inc. Bryan, Ohio 43506 8620-223 Heat Pump Defrost Board Replacement Kit KIT FEATURES This kit is made up of the current defrost control board 8201-129 and a new defrost sensor.

More information

INSTALLATION INSTRUCTIONS HOT GAS BYPASS SYSTEM DESIGN MANUAL

INSTALLATION INSTRUCTIONS HOT GAS BYPASS SYSTEM DESIGN MANUAL INSTALLATION INSTRUCTIONS HOT GAS BYPASS SYSTEM DESIGN MANUAL MODELS: WA242H WA36H NOTE: Electrical data presented in this manualsupersedes any other data for the above listed models. Bard Manufacturing

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS MODELS: WH422D WH44D WH3D Bard Manufacturing Company Bryan, Ohio 43506 Since 94...Moving ahead just as planned. Manual : 20-443 Supersedes: File:

More information

SERVICE MANUAL AIR CONDITIONER SPLIT TYPE

SERVICE MANUAL AIR CONDITIONER SPLIT TYPE FILE No. A90-961 SERVICE MANUAL AIR CONDITIONER SPLIT TYPE WAY CASSETTE TYPE RAV-133TU-PE/RAV-13A-PE RAV-163TU-PE/RAV-18A-PE Printed in UK Dec 1996 s CONTENTS 1. SPECIFICATION...3. CONSTRUCTION VIEWS...5

More information

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW, UC, UG, UW Vintages E, F, G. Last Manufactured: 1988

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW, UC, UG, UW Vintages E, F, G. Last Manufactured: 1988 Replacement Parts List No. 055204700 Revision D 01/2017 McQuay Climate Control Horizontal Water Source Heat Pump CC, CG, CW, UC, UG, UW 610-630 Vintages E, F, G Last Manufactured: 1988 To find your Daikin

More information

Repair Parts List REFRIGERATOR MODEL NUMBER LTF2112ARB. When requesting service or ordering parts, always provide the following information:

Repair Parts List REFRIGERATOR MODEL NUMBER LTF2112ARB. When requesting service or ordering parts, always provide the following information: Repair Parts List REFRIGERATOR MODEL NUMBER LTF2112ARB When requesting service or ordering parts, always provide the following information: - Product Type - Part Number - Model Number - Part Description

More information

Room Air Conditioner SERVICE MANUAL MODEL : LW6013ERY3. CAUTION

Room Air Conditioner SERVICE MANUAL MODEL : LW6013ERY3.   CAUTION www.zenithappliances.com Room Air Conditioner SERVICE MANUAL MODEL : LW6013ERY3 CAUTION BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL. ONLY FOR AUTHORIZED SERVICE PERSONNEL. CONTENTS

More information

Application Guideline and Service Manual

Application Guideline and Service Manual REIDENTIAL AIR CONDITIONER AND HEAT PUMP UING R-22 AND PURONR REFRIGERANT Application Guideline and ervice Manual UNIT IDENTIFICATION... 2 AFETY CONIDERATION... 3 INTRODUCTION... 3 INTALLATION GUIDELINE...

More information

McQuay. Enfinity Vertical Water Source Heat Pump. WFCV, WFCW Design 1. Replacement Parts List No Revision D 03/2018

McQuay. Enfinity Vertical Water Source Heat Pump. WFCV, WFCW Design 1. Replacement Parts List No Revision D 03/2018 Replacement Parts List No. 70006800 Revision D 03/208 McQuay Enfinity Vertical Water Source Heat Pump WFCV, WFCW 007-02 Design To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

Room Air Conditioner CP06 & CP08. Chill 115 Volts. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING _02

Room Air Conditioner CP06 & CP08. Chill 115 Volts. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING _02 Room Air Conditioner Service & Parts Manual 2014-2015 CP06 & CP08 Chill 115 Volts THE EXPERTS IN ROOM AIR CONDITIONING 93011401_02 CONTENTS 1. PREFACE 1.1 SAFETY PRECAUTIONS...2 1.2 INSULATION RESISTANCE

More information

RH1P. Air Handlers. Parts List 09-May-2014

RH1P. Air Handlers. Parts List 09-May-2014 Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-800-.pdf for the current revision. Air Handlers Table of Contents Model Explanation...................................................................................................................

More information

COMFORT PACK INSTALLATION AND MAINTENANCE INSTRUCTIONS

COMFORT PACK INSTALLATION AND MAINTENANCE INSTRUCTIONS R-410A - C MODELS COMFORT PACK PACKAGED THRU-THE-WALL AIR CONDITIONER WITH ELECTRIC HEAT INSTALLATION AND MAINTENANCE INSTRUCTIONS National Comfort Products 539 Dunksferry Road Bensalem, PA 19020 (215)

More information

CMS1402 SERVICE PARTS

CMS1402 SERVICE PARTS This parts lists shows the service parts for the CMS1402 air cooled and the CMS1402 water cooled. A B model was introduced in early 1992, the major change was the front panels. Check the model number of

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS SPLIT AIR CONDITIONER OUTDOOR SECTION Models: HAC481-B HAC602-B For Use With: Matching Indoor Blower Coil Units and Matching Add On Coil Units Only Bard Manufacturing Company,

More information

40E ELECTRIC FAN HEATER

40E ELECTRIC FAN HEATER 40E ELECTRIC FAN HEATER PRODUCT MANUAL IMPORTANT READ AND UNDERSTAND THIS MANUAL BEFORE ASSEM- BLING, STARTING OR SERVICING THE HEATER. IMPROPER USE OF HEATER CAN CAUSE SERIOUS INJURY. KEEP THIS MANUAL

More information

INSTALLATION INSTRUCTIONS MASTER CONTROLLERS MC91AE MC92AE MC93AE MC94AE MC94AEH MC96AEH

INSTALLATION INSTRUCTIONS MASTER CONTROLLERS MC91AE MC92AE MC93AE MC94AE MC94AEH MC96AEH INSTALLATION INSTRUCTIONS MASTER CONTROLLERS MODELS: MC91AE MC92AE MC93AE MC94AE MC94AEH MC96AEH Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. Manual: 2100-189I

More information

Application Guideline and Service Manual

Application Guideline and Service Manual REIDENTIAL AIR CONDITIONER AND HEAT PUMP UING R-22 AND PURONR REFRIGERANT Application Guideline and ervice Manual UNIT IDENTIFICATION... 2 AFETY CONIDERATION... 3 INTRODUCTION... 3 INTALLATION GUIDELINE...

More information

6868 Ardmore Street Houston, Texas Toll Free Phone Fax

6868 Ardmore Street Houston, Texas Toll Free Phone Fax P-09 P-09 P-09A COMPONENT PART NO. COMPONENT PART NO. BASE PAN 67904000 AIR OUTTAKE 67809008 OUTDOOR CENTRIFUGAL FAN 67809032 TURNING WHEEL (CASTER) 67904001 (4) ERECT LOUVER ASSY 67809006 (5) OUTDOOR

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS MODELS W18H1 W24H1 W30H1 W36H1 W42H1 W48H1 W60H1

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS MODELS W18H1 W24H1 W30H1 W36H1 W42H1 W48H1 W60H1 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS MODELS WH W24H WH W3H W42H W4H W0H Bard Manufacturing Company, Inc. Bryan, Ohio 43 Since 94...Moving ahead just as planned. Manual : 20-5B Supersedes:

More information

TECHNICAL SUPPORT MANUAL Fan Coils FVM4X B Series

TECHNICAL SUPPORT MANUAL Fan Coils FVM4X B Series Fan Coils FVM4X B Series DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER is only used

More information

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WGERV-A3 WGERV-C3 WGERV-A5 WGERV-C5 BARD MANUFACTURING COMPANY Bryan, Ohio 4356 Since 1914...Moving ahead, just as planned. Manual:

More information

Bottom Mount Refrigerator Technical Information

Bottom Mount Refrigerator Technical Information Bottom Mount Technical Information Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.! CAUTIN All safety information

More information