GARAGE / WORKSHOP INFRARED HEATERS

Size: px
Start display at page:

Download "GARAGE / WORKSHOP INFRARED HEATERS"

Transcription

1 GARAGE / WORKSHOP INFRARED HEATERS 22,000-25,000 BTU/HR Heater For: Garages / Workshops Barns / Utility Buildings / Storage Sheds Animal Pens / Stalls Loading Docks Building Construction Sites Doorways / Ramps For Snow Prevention America s Most Complete Line Of Infrared Heaters!

2 HIGHLY EFFICIENT AND COST EFFECTIVE RADIANT HEAT. Efficient Infrared Heat - Directly heats people and objects which in turn heats surrounding air to desired temperature. Economical - No electricity required Instant Heat - Includes adjustable thermostat for individually controlled warmth Large Capacity - Heats sq. ft. (2 1 /2 car garage) Convenient - Easy to operate and install Quiet, Clean, Odor-Free Operation - propane or natural gas Gas supply connection is 1/2 dia. (NPT) gas pipe. Ships Complete In Package For Easy Installation Includes Wall Louver For Fresh Air Intake Maintenance Free - No moving parts to service CSA Certified Limited 1 Year Warranty - On gas control Limited 5 Year Warranty - On burner Unique thermopile/thermocouple generates power from pilot flame for gas control. Automatically shuts off gas if pilot light goes out. Aluminized steel burner plenum houses venturi and baffles, enabling air-gas mixture to produce constant grid combustion with no wasted fuel. Millivolt powered thermostat adjusts for individual comfort levels. No electricity required. Chrome-plated, steel grill protects burner from any damaging object. Why Heat A Garage? There are over 40 million single family residential garages in the U.S. SPECIFICATIONS & TECHNICAL DATA BTU/HR. RATING MOUNTING CLEARANCE NORMAL TO COMBUSTIBLES NATURAL MOUNTING MODEL NUMBER GAS PROPANE POSITION TOP SIDE BACK BELOW 22,000* 30º HS22L Stock Number: F HS25N Stock Number: F ,000* 30º Welded wall mounting bracket simplifies installation. A typical 2 car garage represents approximately 20% of the usable space in an average home Garages are the most under-utilized space in most climates during the winter months 55% of all homes have natural gas Cold garage temperatures may affect vehicles and plumbing A heated garage can be used for DIY Auto / Mechanical Maintenance / Workshop / Hobby Activities / Recreation (exercise equipment, table tennis, etc.) / Pet Comfort / Laundry 48 REFLECTOR LxWxH (INCHES) 26 1 /2 x 11 9 /16 x 3 1 / /2 x 11 9 /16 x 3 1 /4 TOTAL LxWxH (INCHES) 29 3 /4 x 12 1 /4 x /4 x 12 1 /4 x 7 SHIPPING WEIGHT (LBS) GAS INLET 1 /2 1 /2 CSA Certified MANIFOLD PRESSURE 10 * Ratings shown are for elevations up to 2,000 feet. (In Canada, refer to rating tag.) For elevations above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level or as specified by local authority having jurisdiction. DO NOT use this in sleeping quarters, mobile homes, or recreational vehicles. Enerco Group Inc West 160th St. Cleveland, Ohio L201

3 ERXL RADIANT TUBE HEATERS 60, ,000 BTU/HR Heaters For: Manufacturing Plants Automobile Dealerships Truck Terminals & Body Shops Repair Shops & Garages Loading Docks Warehouses Farm Buildings Aircraft Hangers Indoor Sporting Arenas Fire Stations Stables Green Houses Custom Applications America s Most Complete Line Of Infrared Heaters!

4 HIGHLY EFFICIENT AND COST EFFECTIVE RADIANT TUBE HEAT. Full 10-Year Limited Warranty 16-Gauge Aluminized Tubing Outside Or Inside Air For Combustion Sealed Burner Control Box Full Cover Polished Aluminum Reflector Installs Easily As Straight Or U-Tube Configurations Features Available In 20 To 60 Foot System Lengths Horizontal Or 45 Degree Angle Of Reflectors Stainless Steel Couplers Chrome Plated Hanging Brackets Burner Sight Glass All Components Are Name-Brand Non-Proprietary 24 Volt Or Line Voltage Thermostat Installation Option SPECIFICATIONS & TECHNICAL DATA CSA Certified MODEL NUMBER BTU x 1000 ERXL 60 N/LP* ERXL 80S N/LP ERXL 80 N/LP ERXL 100S N/LP ERXL 100 N/LP ERXL 125S N/LP ERXL 125 N/LP ERXL 150 N/LP ERXL 150L N/LP ERXL 175 N/LP ERXL 175L N/LP LENGTH MOUNTING CLEARANCE TO COMBUSTIBLES FROM TOP - HORIZONTAL FROM TOP - AT 45º ANGLE 12 STRAIGHT BELOW SIDE TYPICAL MOUNTING HEIGHT SHIPPING WEIGHT (LBS) ELECTRICAL 120 volt-60 Hz Starting Current 5.0 amps Running Current 1.0 amps BURNER Heaters are equipped with a silicon carbide hot surface ignition and electronic safety circuitry COMBUSTION CHAMBER / HEAT EXCHANGER 4 Aluminized steel tubing - 16 gauge GAS SUPPLY Natural Gas Min 4. w.c. - Max 14.0 w.c. LP Gas Min 11.0 w.c. - Max 14.0 w.c. FLUE CONNECTION GAS CONNECTION 4 (O.D.) 1/2 NPT WARRANTY 10-year limited warranty on all electrical components, burner and tubes * N = Natural Gas LP = Propane Enerco Group Inc West 160th St. Cleveland, Ohio L208

5 Model UDAP Page Number of Power Vented, Low Static Axial Fan Unit Heaters for Residential and Commercial/Industrial Use Sizes approved for utility applications such as residential garages under CSA International Requirement U.S. and CR Canada CSA 2.6b ANSI Z83.8b DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED Reznor V3 Series Model UDAP gas-fired unit heaters are available in 14 sizes ranging from 30,000 to 400,000 BTUH gas input. Sizes are approved for residential application. All sizes are approved for commercial/ industrial installations. Model UDAP heaters are designed for 82-83% thermal efficiency and are approved for installation in the United States and Canada by the Canadian Standards Association (CSA). Reznor V3 Series unit heaters have a refreshing new appearance with a glossy white cabinet finish and less visible hardware. Each size cabinet is easily suspended from either 2 or 4 suspension points. Or, an optional hanger kit for Sizes allows for ceiling mounting. The low voltage terminal strip on the outside of the cabinet makes connecting control wiring easy with no panels to remove. The addition of a G terminal to the strip, along with the new design of the circuit board, allows for fan only operation (without adding relays). All units have a factory installed gas line nipple to the exterior of the cabinet for easy gas service connection. The preeminent new internal feature is the Tcore2 heat exchanger and single burner combustion system. Other standard features include a single-stage gas valve, multi-try direct spark ignition with 100% lockout, pressure switch to verify vent flow, resiliently isolated venter motor, venter wheel with improved housing, resiliently isolated axial fan and motor assembly, and a high temperature limit control. Sizes also include a flame rollout safety switch. Operation is controlled through an integrated circuit board. The circuit board monitors heater operation and has LED diagnostic indicator lights to identify abnormalities in control functions. The V3 Series unit heaters are designed to provide all the features you expect in a Reznor heater plus improved efficiency, easier installation, and a new look ~ both inside and out. Look for the unique white unit with no visible front and bottom hardware, deep red louvers, black side handle, and angled corner to know you have a genuine Reznor unit by Thomas & Betts. Sizes certified for residential heating application Sizes certified for commercial/industrial heating application 82-83% Thermal efficient ~ TOP in its class! F Rise range Tcore 2 titanium stabilized aluminized steel heat exchanger Patented** Tcore 2 single burner combustion system including a one-piece burner assembly 115/1/60 Supply voltage 115 Volt open fan motor with internal overload protection Transformer for 24-volt controls Integrated circuit board with diagnostic indicator lights Multi-try direct spark ignition with 100% lockout Fan relay (included on the circuit board) Single-stage natural gas valve (field adjustable for operation to 9,000 ft. elevation) Vibration/noise isolated fan and venter motors ~ designed for low noise operation 2-pt and 4-pt Suspension ~ standard on all sizes External terminal strip for 24-volt wiring External gas connection Full fan guard ~ engineered for safety Improved cabinet design with less visible hardware and a NEW Reznor appearance Single-stage, propane gas valve (field adjustable for operation to 9,000 ft. elevation) Two-stage natural gas or propane gas valve - Sizes or 316 Stainless steel heat exchangers 208 or 230 Single phase voltage Totally enclosed fan motor (Sizes , 115V only) Common venting with other gravity vented Category I appliance(s) (Sizes ) * * U.S. Patent No. 6,889,686 Form RZ-C-UH (Version H) Page 8

6 OPTIONAL FEATURES - FIELD INSTALLED Vent cap Thermostat Thermostat guard with locking cover Vertical louvers ~ new design Downturn nozzle kits ~ new design Gas conversion kits (natural and propane) Master/Slave controls for zoning up to six units Ceiling suspension kit - Sizes Hanger kits for 1 pipe Stepdown transformer (for 230/3 and 460/3 supply voltage) Manual shutoff valves Page Number of TECHNICAL DATA Model UDAP Size Input Heating Capacity BTUH 30,000 45,000 60,000 75, , , , , , , , , , ,000 kw/h Thermal Efficiency (%) Output Heating BTUH 24,600 37,350 49,800 62,250 87,150 99, , , , , , , , ,000 Capacity A kw/h Gas Connection Natural 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 (inches) B Propane 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 Vent Connection Size C (inches diameter) Control Amps (24 volt) Full Load Amps (115 volt) Maximum Over Current Protection (115V) D Normal Power Consumption (watts) Discharge Air Temperature Rise ( F) Air Volume CFM M 3 /minute Discharge Air Opening ft Area M Output Velocity FPM M/minute Open /30 1/20 1/6 1/6 1/6 1/4 1/4 1/2 1/2 1/2 Fan Motor HP E Enclosed /4 1/4 1/4 1/4 1/4 1/4 1/4 1/2 1/2 1/2 Fan Motor RPM Fan Diameter (inches) Sound Level 15 ft Approximate Net lbs Weight kg Approximate Ship lbs Weight kg A CSA rating for altitudes to 2000 ft. B Size shown is for gas connection to a single stage gas valve, not supply line size. C Smaller or larger vent pipe diameters may be allowed; refer to the Venting Installation Manual, Form I-V-PV. If vent diameter is different from vent connection, reducer/enlargers will be field-required. D MODP = 2.25 x (largest motor FLA) + smallest motor FLA. Answer is rounded to the nearest commercially available circuit breaker. E All other information in this table is based on a heater equipped with a standard 115 volt open fan motor. Form RZ-C-UH (Version H) Page 9

7 Model UDAP ±1/16" (2mm) Page Number of Size A B C D E F G H J K M N P Q R 30, /8 25 5/ / /16 5 3/16 6 1/2 2 11/16 3 7/8 17 3/8 11/16 4 5/ / /8 25 5/ / /16 7 7/8 6 1/2 5 1/2 3 7/8 17 3/8 11/16 4 5/ / /8 25 5/ / /8 21 9/16 7 7/8 6 1/2 5 1/2 3 7/8 17 3/8 11/16 4 5/ / /8 25 5/ / /8 21 9/ /2 6 1/2 8 3/4 3 7/8 17 3/8 11/16 4 5/ / /8 25 5/ / /8 21 9/ /2 6 1/2 8 3/4 3 7/8 17 3/8 11/16 4 5/ /2 150, 175, /8 38 3/ /8 8 1/2 8 1/4 5 7/16 6 1/ /16 1 3/8 8 3/ / /8 225, /8 38 3/ /8 13 1/ / / /16 1 3/8 8 3/ / /8 300, 350, / /8 17 1/ /16 7 5/ /16 1 3/8 8 3/ / /16 Size A B C D E F G H J K M N P Q R 30, 45 (308) (651) (254) (351) (660) (548) (132) (165) (68) (98) (441) (17) (110) (330) (243) 60 (384) (651) (330) (351) (686) (548) (200) (165) (140) (98) (441) (17) (110) (330) (267) 75 (384) (651) (330) (351) (702) (548) (200) (165) (140) (98) (441) (17) (110) (330) (267) 100 (587) (651) (533) (351) (727) (548) (368) (165) (222) (98) (441) (17) (110) (330) (267) 125 (587) (651) (533) (351) (746) (548) (368) (165) (222) (98) (441) (17) (110) (330) (267) 150, 175, 200 (511) (970) (406) (584) (1,067) (899) (216) (210) (138) (165) (652) (35) (208) (564) (416) 225, 250 (664) (970) (559) (584) (1,067) (899) (332) (224) (229) (165) (652) (35) (208) (564) (397) 300, 350, 400 (867) (1,041) (762) (584) (1,067) (899) (433) (229) (300) (186) (703) (35) (208) (564) (411) CLEARANCES FROM COMBUSTIBLES Form RZ-C-UH (Version H) Page 10 Top Flue Connector Access Panel Non-Access Side Bottom* Rear Size inches mm inches mm inches mm inches mm inches mm inches mm *Suspend the heater so that the bottom is a minimum of 5 (1.5M) above the floor.

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F) UNIT HEATER CATALOG Form RZ-NA-C-UH (Version F) BACKGROUND Reznor was founded in 1888 to manufacture the Reznor reflector heater, which used a luminous flame gas burner developed by George Reznor. This

More information

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters Sizes 30-125 carry an additional approval for use in residential garage/workshops under CSA International Requirement 10.96 - U.S.

More information

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil UNIT HEATER CATALOG COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS FUEL Natural Gas Propane Fuel Oil CAPACITIES 25-1,200 MBH 80% - 93% Thermal Efficiency 380-16,750 CFM AIR DELIVERY Propeller

More information

CATALOG: HVAC - Gas Space Unit Heating

CATALOG: HVAC - Gas Space Unit Heating CATALOG: HVAC - **Wolff Bros. Supply, Inc. reserves the right to substitute like products. Product information is subject to Manufacturer rolling changes and/or typographical errors. Wolff Bros. Supply,

More information

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F) UNIT HEATER CATALOG Form RZ-NA-C-UH (Version F) BACKGROUND Reznor was founded in 1888 to manufacture the Reznor reflector heater, which used a luminous flame gas burner developed by George Reznor. This

More information

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP CATALOG 9-117.1 JUNE, 2003 TABLE OF CONTENTS Modine's TLP Series sets the industry standard for low intensity infrared heating performance

More information

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

GAS-FIRED HIGH INTENSITY INFRARED HEATERS GAS-FIRED HIGH INTENSITY INFRARED HEATERS CATALOG 9-116.1 MARCH, 2003 TABLE OF CONTENTS Modine's MT Series is a gas-fired, high intensity ceramic infrared heater. Ideal for spot heating, the MT series

More information

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas HVAC Guideline Specifications WHISPER-JET: SET SERIES Two Stage Positive Pressure Gas-Fired Infrared Radiant Tube Type Heater Commercial/Industrial Applications Technical Summary Input Range: 80,000/60,000

More information

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh PRODUCT SPECIFICATIONS GAS UNIT HEATERS / DUCT FURNACES TU T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ Bulletin No. 20402 November 207 Supersedes November 206

More information

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS SECTION 15540 FUEL- FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS) This section is based

More information

Infrared Heating Catalog

Infrared Heating Catalog INFRA-REZ HEATER Low-Intensity Infrared Model TRP - Packaged Tubular Radiant Heater Model TR - Modular Tubular Radiant Heater High-Intensity Infrared Model RIH/RIHV - Surface Combustion Radiant Heaters

More information

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh GAS UNIT HEATERS / DUCT FURNACES LF24 COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ PRODUCT SPECIFICATIONS Bulletin 2008 July 206 Supersedes October 20 Steady-State Efficiency - up to 8% Input

More information

INFRARED RADIANT HEATERS

INFRARED RADIANT HEATERS IRH-1R INFRARED RADIANT HEATERS High and Low Intensity RSU SERIES Unit is shown rotated at a 45 angle. RSD SERIES HIGH INTENSITY INFRARED HEATERS RSD Series Ceramic Heaters Special Honeycomb Tile Design

More information

SUBMITTAL SCHEDULE & DATA

SUBMITTAL SCHEDULE & DATA SUBMITTAL SCHEDULE & DATA Gas- and Oil-Fired Unit Heaters, Infrared Heaters, and Indoor Duct Furnaces Job Name: Date: 10/31/2016 Location: Engineer: Submitted by: Jeff Musto Architect: Contractor: Model

More information

Mi-T-M carries a full line of portable heaters, built in the same quality tradition you ve come to expect from us.

Mi-T-M carries a full line of portable heaters, built in the same quality tradition you ve come to expect from us. Why Mi-T-M? Mi-T-M space heaters deliver powerful instant heat right where you need it. Whether you require heat for your workshop, job site or any other outdoor setting these portable units can be moved

More information

Installation / Operation. Applies to: Standard Power Vent Unit Heaters: Separated Combustion Unit Heaters:

Installation / Operation. Applies to: Standard Power Vent Unit Heaters: Separated Combustion Unit Heaters: Document No D300519 (4-8-16) Obsoletes Document No D300519 (04-15) Installation / Operation Applies to: Standard Power Vent Unit Heaters: Separated Combustion Unit Heaters: NOTE: Accessories referenced

More information

1.03 DELIVERY, STORAGE, AND HANDLING Heater will be stored to secure against damage and handled per manufacturer s recommendations.

1.03 DELIVERY, STORAGE, AND HANDLING Heater will be stored to secure against damage and handled per manufacturer s recommendations. HVAC Guideline Specifications supraschwank Packaged Luminous Infrared Radiant Gas Heater Combined Intensity (produces both Low and High Intensity radiant output) Commercial/Industrial Applications Size

More information

RADIANT HEATER CATALOG

RADIANT HEATER CATALOG RADIANT HEATER CATALOG COMMERCIAL/INDUSTRIAL RADIANT HEATERS Heats Objects and People, Not the Air STYLES Low Intensity Tubular Radiant - Single-Stage - Two-Stage - Harsh Environment High Intensity Radiant

More information

8+* Bulletin No November 1997

8+* Bulletin No November 1997 ENGINEERING DATA VALUE 80Z UP-FLOW/HORIZONTAL GAS FURNACES *80.0 to 80.5% A.F.U.E. 45,000 to 20,000 Btuh (3.2 to 32.2 kw) Input Heating Capacity -/2 thru 6 Tons (3.5 thru 2. kw) Nominal Add-on Cooling

More information

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces SG-UUH-03 November 2014 Specification Guide FSA, FOA, & HED Series Unit Heaters and Duct Furnaces Product improvement is a continuous process at Advanced Distributor Products. Therefore, product specifications

More information

GAS-FIRED HIGH AND LOW INTENSITY INFRARED HEATERS

GAS-FIRED HIGH AND LOW INTENSITY INFRARED HEATERS GAS-FIRED HIGH AND LOW INTENSITY INFRARED HEATERS MODEL IHR MODEL OHP MODEL IPT JANUARY, 2019 2 TABLE OF CONTENTS This catalog describes the design and construction features and benefits, typical applications,

More information

SERIES. 10 year limited warranty on Burner Core 5 year limited warranty on All combustion and. 2 year limited warranty on All Burner Controls

SERIES. 10 year limited warranty on Burner Core 5 year limited warranty on All combustion and. 2 year limited warranty on All Burner Controls TM SERIES Available with 40,000 to 200,000 BTU/Hr. inputs and tube lengths from 10 feet to 70 feet. Aircraft Hangars Auto Dealerships Farm Buildings Fire Stations Body Shops Car Washes Sports Facilities

More information

INDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG

INDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG INDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG COMMERCIAL/INDUSTRIAL AIR HANDLER AND CONDENSING UNIT AIR HANDLER CAPACITIES 563-7,593 CFM Air 20-400 MBH Heating (Gas/LP) 10-120 kw Heating (Electric) 5-20 Tons

More information

Parts List for Ener-Radiant XL Tube Heaters

Parts List for Ener-Radiant XL Tube Heaters Parts List for Ener-Radiant XL Tube Heaters ERXL-0 F09XL ERXL-0 NG / BRN & Cont Box 0 Front Flange F09XL ERXL-0 LP / BRN & Cont Box 009 Reflector End Cap F00XL Tube Set- 0' 099 Spring Clips 0 Tube H.E.

More information

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE). This document was created with FrameMaker 4.0.4 SIZES AVAILABLE: 024065 through 060150 EFFICIENCY: IGNITION: HEAT EXCHANGER: CONTROL BOARD: The GA1A Induced-Combustion Gas Furnace provides the efficiency

More information

Series Fan-Type Unit Heaters

Series Fan-Type Unit Heaters Series Fan-Type Unit Heaters C E T I F I E D Installation/Operation FOM Z-NA I-UDA APPLIES TO: Models UDAP and UDAS Table of Contents Page Warnings... 1 Installation/Operation... 2-25 Check/Test/Startup...

More information

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES SIZES AVAILABLE: 024045 through 060155 EFFICIENCY: The GB1AAV Induced-Combustion Gas Furnace provides the efficiency customers want with 80% Annual Fuel Utilization Efficiency (AFUE). IGNITION: The field-proven

More information

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS SECTION 15540 FUEL- FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS)

More information

Omega II SUBMITTAL DATA. Pre Engineered Packages. Products by: COMBUSTION RESEARCH CORPORATION PROJECT: LOW-INTENSITY INFRARED HEATING SYSTEMS

Omega II SUBMITTAL DATA. Pre Engineered Packages. Products by: COMBUSTION RESEARCH CORPORATION PROJECT: LOW-INTENSITY INFRARED HEATING SYSTEMS LOW-INTENSITY INFRARED HEATING SYSTEMS Omega II Pre Engineered Packages Products by: COMBUSTION SUBMITTAL DATA PROJECT: Specifications for Omega II UNITARY P.E.P. SYSTEMS PART 1 - GENERAL It is the intent

More information

MERIT SERIES Downflow

MERIT SERIES Downflow PRODUCT SPECIFICATIONS GAS FURNACES ML80DF MERIT SERIES Downflow Bulletin No. 20643 February 208 Supersedes November 207 AFUE - 80% Input - 44,000 to 0,000 Btuh Nominal Add-on Cooling -.5 to 5 Tons MODEL

More information

Cumberland Heating Systems

Cumberland Heating Systems Cumberland Heating Systems Cumberland "Radiant" Brooder Clean Burning...Fuel Efficient Maintaining proper in-house temperature is critical in climate control. A consistent, stressfree environment promotes

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGF1RA Series M1010 Product Line High Efficiency / Upflow / Horizontal Gas Furnace Induced Draft - 80+ AFUEurnace 2 10 YEAR WARRANTY WORRY-FREE PERFORMANCE 5 YEAR DEPENDABILITY

More information

Series Unit Heaters (Fan Models)

Series Unit Heaters (Fan Models) C E T I F I E D Series Unit Heaters (Fan Models) Installation/Operation FOM Z-NA I-UD APPLIES TO: Models UDAP and UDAS Table of Contents Page arnings... 1 Installation/Operation. 2-25 Check/Test/Startup...

More information

ELITE SERIES Downflow - High Efficiency Blower Motor

ELITE SERIES Downflow - High Efficiency Blower Motor PRODUCT SPECIFICATIONS GAS FURNACES EL80DFE ELITE SERIES Downflow - High Efficiency Blower Motor Bulletin No. 2066 July 208 Supersedes February 208 AFUE - 80% Input - 44,000 to 0,000 Btuh Nominal Add-on

More information

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models July, 2009 Gas-Fired Power Vented Unit Heaters Propeller & Blower Models MODEL HD MODEL HDB MODEL PDP MODEL BDP TABLE OF CONTENTS Modine s power vented unit heaters are designed for the heating requirements

More information

HVAC HEATING PRODUCTS

HVAC HEATING PRODUCTS GTFC-7 HVAC HEATING PRODUCTS Application Manual SF/SC Series TF/TC Series GG Series TUBULAR GAS-FIRED UNIT HEATERS Contents PAGE GENERAL INFORMATION All Series 2 GG SERIES Standard/Optional Features 3

More information

NOTICE: The information contained on the following page(s) was produced prior to May 1, On that date Reznor became part of Nortek, Inc.

NOTICE: The information contained on the following page(s) was produced prior to May 1, On that date Reznor became part of Nortek, Inc. NOTICE: The information contained on the following page(s) was produced prior to May 1, 2014. On that date Reznor became part of Nortek, Inc. References to any other company affiliations are no longer

More information

LF24. UNIT HEATERS Horizontal - 60 HZ. Thermal Efficiency - up to 80.5% Input - 100,000 to 390,000 Btuh LF A MODEL NUMBER IDENTIFICATION

LF24. UNIT HEATERS Horizontal - 60 HZ. Thermal Efficiency - up to 80.5% Input - 100,000 to 390,000 Btuh LF A MODEL NUMBER IDENTIFICATION E N G I N E E R I N G D ATA G A S U N I T H E A T E R S / D U C T F U R N A C E S LF4 UNIT HEATERS Horizontal - 60 HZ Bulletin. 0000 June 0 Supersedes February 0 Front View Tubular Heat Exchanger Thermal

More information

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS SECTION 15540 - FUEL - FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS)

More information

CLEARANCES TO COMBUSTIBLES

CLEARANCES TO COMBUSTIBLES 12288 Brawn Road 22, Wainfleet, Ontario, Canada L0S 1V0 Phone: 905-899-3473 Fax: 905-899-2262 www.easyradiantworks.com email: erw@vaxxine.com Engineering Submittal Data EZB series straight and U shape

More information

STS-JZ (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS

STS-JZ (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS SUBMITTAL DATA (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS PROJECT: ENGINEER: CONTRACTOR: DISTRIBUTOR: SCHWANK MODEL #: FUEL: APPROVED BY: DATE: APPROVAL #: 1 Submittal NOTICE:

More information

GAS-FIRED HIGH AND LOW INTENSITY INFRARED HEATERS

GAS-FIRED HIGH AND LOW INTENSITY INFRARED HEATERS GAS-FIRED HIGH AND LOW INTENSITY INFRARED HEATERS MODEL IHR MODEL OHP MODEL IPT 9-123.2 SEPTEMBER, 2016 9-123.2 FEATURES AND BENEFITS - MODEL IHR Figure 4.1 - Construction Features - Model IHR Features

More information

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace TECHNICAL SPECIFICATIONS M3RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 90+ AFUE Input 60,000 & 80,000 Btuh The high efficiency downflow gas furnace is especially

More information

G34M Bulletin #69/ August 2003

G34M Bulletin #69/ August 2003 ENGINEERING DATA G34M MULTI POSITION GAS FURNACE 12.4 to 31.0 kw Output 52.7 to 131.9 Mj Input 3.5 to 17.6 kw Nominal Add-on Cooling GAS FURNACES 50 Hz G34M Bulletin #69/490045 August 2003 Typical Applications

More information

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters Heating Systems Brooders, Space Heaters and QuadRadiant Heaters Let s grow together. QUADRATHERM QuadRadiant Heater Patent Pending With Chore-Time s QUADRATHERM Heater, the Most Innovative Concept in Heating

More information

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM BURNERS/ FLARES VAREC BIOGAS 4W Series WASTE GAS BURNER & IGNITION SYSTEM The Varec Biogas 4W Series Waste Gas Burner is a highly reliable flare and ignition system ideal for use in burning excess biogas.

More information

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 95%+ AFUE Input 45,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially

More information

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL POWER VENTED HD, HDB, PDP, BDP, PTP, BTP SEPARATED COMBUSTION HDS, HDC, PTS, BTS HIGH-EFFICIENCY SEPARATED COMBUSTION PTC, BTC 6-107.16 NOVEMBER,

More information

BTUC-4 TUBULAR GAS-FIRED UNIT HEATERS

BTUC-4 TUBULAR GAS-FIRED UNIT HEATERS BTUC-4 TUBULAR GAS-FIRED UNIT HEATERS Table of Contents Models BTU & BRU General Information 3 Performance and Dimensional Data 4, 5 Model Number Description 6 Model BST General Information 7 Performance

More information

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G11-490 GAS FURNACES RGLR- SERIES ECM Equipped Models with Input Rates from 75,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single-Phase [22 to 37 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

Portable Radiant Heaters. Convection Heaters FEATURES: MTankCo.com LEADERSHIP INTEGRITY

Portable Radiant Heaters. Convection Heaters FEATURES: MTankCo.com LEADERSHIP INTEGRITY PROPANE HEATERS Convection Heaters Portable Radiant Heaters FEATURES: HS80CVX heats approx. 2,000 sq. ft. and runs up to 14 hrs. on 20lb. tank (low) HS200CVX heats approx. 5,000 sq. ft. and runs up to

More information

U n i t H e at e r s

U n i t H e at e r s Unit Heaters LF Models Enduring performance Allied commercial unit heaters are built to last, season after season Designed and built for durability and peak performance, Allied Commercial unit heaters

More information

Commercial Tankless Rack System

Commercial Tankless Rack System TANKLESS WALL MOUNT LIGHTWEIGHT Constructed of anodized aluminum frame Utilizes the industry s lightest 199,000 BTU high efficiency condensing tankless heater EXPANDABLE Multiple design and installation

More information

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E WATER HEATERS / BOILERS -E PRODUCT SPECIFICATIONS Gas-Fired Steam Boiler Bulletin No. 20653 September 202 Supersedes Bulletin No. 20263 AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh MODEL NUMBER

More information

Gas-Fired Indoor and Outdoor Duct Furnaces

Gas-Fired Indoor and Outdoor Duct Furnaces July, 2008 Gas-Fired Indoor and Outdoor Duct Furnaces INDOOR GRAVITY VENTED DFG, DBG, DCG INDOOR SEPARATED COMBUSTION DFS, DBS, DCS OUTDOOR GRAVITY AND POWER EXHAUSTED H Series table of contents A complete

More information

bring value to your space

bring value to your space PTP unit heaters can use natural or propane gas, and are available in single-stage or optional two-stage controls. bring value to your space with THE NEW PTP HEATER. Introducing the new power vented, PTP

More information

13 GEP A L P - 1 A

13 GEP A L P - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800

More information

RG7D 1-Stage Heat Series

RG7D 1-Stage Heat Series TECHNICAL SPECIFICATIONS RG7D 1-Stage Heat Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace

More information

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b PRODUCT SPECIFICATIONS OIL FURNACES El083b ELITE SERIES Lo-Boy Bulletin No. 20629 February 209 Supersedes July 202 MODEL NUMBER IDENTIFICATION el O 83 bf 0/4 p 60 AFUE - 83% Heating Input - 0,000 to 5,000

More information

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL POWER VENTED HD, HDB, PDP, BDP, PTP SEPARATED COMBUSTION HDS, HDC, PTS, BTS HIGH-EFFICIENCY SEPARATED COMBUSTION PTC, BTC 6-107.14 JULY, 2013

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 93% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 93% AFUE, all models all positions F9MES 50 Hz Product Specifications Certified to leak 2% or less of nominal air conditioning CFM delivered when

More information

REFERENCE INFORMATION

REFERENCE INFORMATION REFERENCE INFORMATION HOW MUCH HEAT DO YOU NEED? You can calculate the amount of BTUs required by using the following method: PROPANE/LP VAPORIZATION RATE (Per 100 lb. Propane Cylinder) 100 lb. 40 lb.

More information

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2. P R O D U C T S P E C I F I C AT I O N S G A S F U R N A C E S G6MP ELITE Series Multi-Position - Two-Stage Heat Bulletin No. 038 August 009 Supersedes December 008 AFUE - Up to 95% Input - 44,000 to 3,000

More information

Commercial Tankless Rack System

Commercial Tankless Rack System TANKLESS WALL MOUNT LIGHTWEIGHT Constructed of anodized aluminum frame Utilizes the industry s lightest 199,000 BTU high efficiency condensing tankless heater EXPANDABLE Multiple design and installation

More information

Commercial Tankless Rack System

Commercial Tankless Rack System TANKLESS FREE STANDING BACK-TO-BACK LIGHTWEIGHT Constructed of sturdy metal frame Utilizes the industry s lightest 199,000 BTU high efficiency condensing tankless heater EXPANDABLE Multiple design and

More information

TOLL FREE HEATSTAR OVERHEAD & VENT FREE HEATERS

TOLL FREE HEATSTAR OVERHEAD & VENT FREE HEATERS Enerco Group Inc. SHIPPING ADDRESS MAILING ADDRESS NEW PRODUCTS 22801 Aurora Rd., Ste. 3 & 4 PO Box 6660 Bedford Heights, OH 44146 Cleveland, Ohio 44101 www.enerco.com TOLL FREE 1 866 447 2194 2017 HEATSTAR

More information

ADF/ADFH 300 and 500

ADF/ADFH 300 and 500 MODEL ADF/ADFH DIRECT-FIRED SYSTEMS TECHNICAL DATA Four Sizes - 300, 500, 700, 1200 Horizontal Configuration with Full Curb Cap Base Horizontal or Vertical (down) Discharge Indoor/Outdoor Installation

More information

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh HEATERS / BOILERS GWB8-E PRODUCT SPECIFICATIONS Gas-Fired Hot Water Boiler Bulletin No. 065 September 0 Supersedes Bulletin No. 06 AFUE up to 83.9% Heating Input 50,000 to 99,000 Btuh MODEL NUMBER IDENTIFICATION

More information

Form C-IR (Version F) COMMERCIAL/INDUSTRIAL RADIANT HEATERS. Heats Objects and People, Not the Air

Form C-IR (Version F) COMMERCIAL/INDUSTRIAL RADIANT HEATERS. Heats Objects and People, Not the Air Page of RADIANT HEATER CATALOG COMMERCIAL/INDUSTRIAL RADIANT HEATERS Heats Objects People, Not the Air STYLES Low Intensity Tubular Radiant - Single-Stage - Two-Stage - Harsh Environment High Intensity

More information

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace XL 95 TUH2B060A936VA, TUH2B080A92VA, TUH2C100A98VA, TUH2D1A960VA, TDH2B060A936VA, TDH2B080A92VA, TDH2C100A98VA, TDH2D1A960VA

More information

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE TANKLESS WALL MOUNT LIGHTWEIGHT Constructed of anodized aluminum frame Utilizes the industry s lightest 199,000 BTU high efficiency condensing tankless heater EXPANDABLE Multiple design and installation

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

Brooders. Better Brooding for Your Chicks... Since 1924

Brooders. Better Brooding for Your Chicks... Since 1924 Brooders Better Brooding for Your Chicks... Since 1924 Bright, warm glow Increased floor heat Fuel efficient and durable Reliable ignition features Easy to clean and assemble Shenandoah s 42,000 and 40,000

More information

Synergy WARNING FOR YOUR SAFETY. High Intensity Infrared Heaters. Installation, Service, and Maintenance Manual COMBUSTION RESEARCH CORPORATION

Synergy WARNING FOR YOUR SAFETY. High Intensity Infrared Heaters. Installation, Service, and Maintenance Manual COMBUSTION RESEARCH CORPORATION COMBUSTION RESEARCH CORPORATION Synergy High Intensity Infrared Heaters Installation, Service, and Maintenance Manual! WARNING Improper installation, adjustment, alteration, service or maintenance can

More information

SUBMITTAL DATA S100 & S100U POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS. Page 1 PROJECT: ENGINEER: CONTRACTOR:

SUBMITTAL DATA S100 & S100U POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS.  Page 1 PROJECT: ENGINEER: CONTRACTOR: SUBMITTAL DATA & U POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS PROJECT: ENGINEER: CONTRACTOR: DISTRIBUTOR: SCHWANK MODEL #: FUEL: APPROVED BY: DATE: APPROVAL #: www.schwankgroup.com Page

More information

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR FORM NO. G22-506 Supersedes Form No. G22-506 Rev. 1 GAS FURNACES RGLT- SERIES Models with Input Rates from 75,000 to 125,000 BTU/HR [22 to 37 kw] (U.S. & Canadian Models) Annual Fuel Utilization Efficiency

More information

Gas-Fired Heating Equipment

Gas-Fired Heating Equipment BTUC- GAS-FIRED UNIT HEATERS BSF/BSC Series BTU/BTC Series BRT Series Gas-Fired Heating Equipment Tubular Unit Heaters Duct Furnaces Contents PAGE Tubular Unit Heaters GENERAL INFORMATION Tubular Unit

More information

Engineering Submittal Data PPRTH Patio Radiant Tube Heaters.

Engineering Submittal Data PPRTH Patio Radiant Tube Heaters. 12288 Brawn Road 22, Wainfleet, Ontario, Canada L0S 1V0 Phone: 905-899-3473 Fax: 905-899-2262 www.easyradiantworks.com email: erw@vaxxine.com P For either indoor or outdoor installation. Not for use in

More information

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006 Submittal Prepared For: All Bidders Sold To: Date: January 8, 209 Customer P.O. Customer Project Job Job Name: City of Carrollton Fire Splits 623 Beltline Road CARROLLTON, TX 75006 Trane U.S. Inc. dba

More information

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES P R O D U C T S P E C I F I C AT I O N S W A T E R H E A T E R S / B O I L E R S CONSERVATOR Gas-Fired Steam Boiler Bulletin No. 20263 October 200 Supersedes September 2008 AFUE up to 82.7% Heating Input

More information

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input Product Data 58EFA Horizontal Gas Furnace 50,000 125,000 Btuh Input GAS SUPPLY MANUAL SHUTOFF VALVE SEDIMENT TRAP UNION Carrier presents the 58EFA, a dedicated horizontal gas furnace that excels in the

More information

Residential/Commercial Gas Condensing Tankless Models

Residential/Commercial Gas Condensing Tankless Models 15-Year Residential/1-Year Commercial Heat Exchanger Limited Warranty/5-Year Parts Warranty* FEATURES Ultra-Low NOx Condensing Technology Provides Unprecedented.95 Energy Factor Durable Heat Exchanger

More information

Greater temperature control

Greater temperature control Brighter glow Easy to clean and hang Increased floor heat features Greater temperature control Ignition options The Ultimate in Reliable, Efficient Radiant Heat Ultra-Ray Broad Comfort Zone Heats an average

More information

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2. G A S F U R N A C E S G61MP ELITE SERIES Multi Position Two Stage Heat E N G I N E E R I N G D A T A Bulletin No. 210382 September 2006 Supersedes August 2006 AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal

More information

! WARNING: FIRE OR EXPLOSION HAZARD. Applies to: Model SC, Separated-Combustion Duct Furnace. Model SC INSTALLATION / OPERATION / MAINTENANCE

! WARNING: FIRE OR EXPLOSION HAZARD. Applies to: Model SC, Separated-Combustion Duct Furnace. Model SC INSTALLATION / OPERATION / MAINTENANCE Form I-SC (05-15) Obsoletes Form I-SC (12-14) INSTALLATION / OPERATION / MAINTENANCE Applies to: Model SC, Separated-Combustion Duct Furnace Model SC CUSTOMER CQS AGENCY CONVERGENT QUALITY SYSTEM PRODUCT

More information

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

Tankless Condensing High Efficiency Water Heaters with Built-In Pump Tankless Residential Water Heater Series Tankless Condensing High Efficiency Water Heaters with Built-In Pump Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to an unprecedented

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVN/P-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7/CSA 21.4 2000 Gas Fired Construction

More information

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa) 80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Series B approved for Twinning applications (0902116, 1002122, and 1352422) with accessory (order separately) Supports two stage cooling

More information

RADIANT HEATER CATALOG

RADIANT HEATER CATALOG RADIANT HEATER CATALOG COMMERCIAL/INDUSTRIAL RADIANT HEATERS Heats Objects and People, Not the Air STYLES Low Intensity Tubular Radiant - Single-Stage - Two-Stage - Harsh Environment High Intensity Radiant

More information

FEATURES AND BENEFITS

FEATURES AND BENEFITS FEATURES AND BENEFITS Product Features and Benefits Full Product Line Offering Feature All models are 80% thermally efficient Blower performance up to 3.0 W.C. DX or chilled water section with factory

More information

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents TABLE OF CONTENTS A complete line of commercial, industrial, and residential heating equipment is offered. This catalog describes in detail the gas-fired, gravity and power vented, commercial/ industrial

More information

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY TANKLESS WALL MOUNT LIGHTWEIGHT Constructed of anodized aluminum frame Utilizes the industry s lightest 199,000 BTU/h high efficiency condensing tankless heater EXPANDABLE Multiple design and installation

More information

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES: TANKLESS CONDENSING HIGH EFFICIENCY COMMERCIAL GAS Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to 0.95 Uniform Energy Factor (UEF) which lowers operating costs and

More information

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace XR 95 TUHB00A92C, TUHB060A936C, TUHB080A92C, TUHC080A960C, TUHC00A98C, TUHD00A960C, TUHDA960C, TDHB00A92C, TDHB065A92C,

More information

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA Navien America Inc. Specification Details for the Navien models: CR-210 CR-210A For Indoor Installation Only For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA,

More information

Downflow/Horizontal Right Induced Draft Gas Furnace

Downflow/Horizontal Right Induced Draft Gas Furnace Downflow/Horizontal Right Induced Draft Gas Furnace American Standard 80 ADE1A060A9361A, ADE1B060A9361A ADE1B080A951A, ADE1B100A951A ADE1C100A9601A, ADE1D120A9601A Single-Stage Fan Assisted Combustion

More information

MERIT SERIES Downflow

MERIT SERIES Downflow PRODUCT SPECIFICATIONS GAS FURNACES ML95DF MERIT SERIES Downflow Bulletin No. 06 February 08 Supersedes November 07 MODEL NUMBER IDENTIFICATION AFUE - 95% Input - 44,000 to 0,000 Btuh Nominal Add-on Cooling

More information

Commercial Tankless Rack System

Commercial Tankless Rack System TANKLESS FREE STANDING BACK-TO-BACK LIGHTWEIGHT Constructed of sturdy metal frame Utilizes the industry s lightest 199,000 BTU high efficiency condensing tankless heater EXPANDABLE Multiple design and

More information

Series RE Infrared Heater

Series RE Infrared Heater Series RE Infrared Heater Installation, Operation and Service Instructions WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage,

More information

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS CONDENSING TANKLESS WITH INTEGRATED RECIRCULATION PUMP COMMERCIAL-GRADE RESIDENTIAL Ultra-Low NOx gas tankless water heaters with condensing technology featuring an up to 0.95 Uniform Energy Factor (UEF)

More information