Wall Mounted. More information on controls and options on pages
|
|
- Denis Murphy
- 5 years ago
- Views:
Transcription
1 Wall Mounted 28 More information on controls and options on pages
2 WLL MOUNTED Hitachi offers a wide range of stylish and highly-efficient wall mounted systems suitable for a variety of applications SUMMIT RK PEB pages 32 and NEW PERFORMNCE RK RPB pages 34 and 35 RK PP pages 34 and NEW SHIROKUM RK RXB pages 36 and S-SERIES RK PSB pages 38 and UTOPI ES RPK 3.0 FSN3M pages 40 and UTOPI IVX COMFORT RPK FSN3M pages 42 and UTOPI IVX PREMIUM RPK FSN3M pages 44 and 45 29
3 Wall Mounted UTOPI ES PC RF RPK 3.0FSN(H)3M PC RT RS 3HVRNS3 Indoor units Nominal cooling capacity 7.1kW Nominal heating capacity 8.0kW Low consumption motor Modern sleek design Ideal for offices and shops utomatic restart Easily accessible filters Built-in infra-red receiver. Remote controllers dvanced PC-RF wired LED 5 time ranges with different temperatures (reduced, weekly, holiday etc) Service menu and optional function menus, add your contact details to be shown when there is an error Standard PC-RT wired remote 4 prograable weekly schedules Service menu, optional function menu and fault diagnostic lternative option: infra-red or simplified remote control - see pages Outdoor units Compact design single fan vailable in single phase RPK 3.0FSN(H)3M 40 More information on controls and options on pages
4 UTOPI ES Wall Mounted INDOOR UNITS RPK 3.0FSN3M Nominal Cooling Capacity (min - max) (1) kw 7.1 ( ) Nominal Heating Capacity (min - max) (2) kw 8.0 ( ) UK Cooling Capacity (sensible) (3) kw 7.4 (5.5) Seasonal Efficiency SEER (4) 4.66 B Seasonal Efficiency S (4) (verage Climate) 3.81 Nominal Load Efficiency EER / (5) Energy Class (Cool/Heat) 2.81 / 2.93 C / D Noise Level (sound pressure) L / M / H / H1*) (6) db() 36/40/43/49 Noise level (sound power) (8) db() 59 ir flow cooling mode (L / M / H / H1*) m 3 /h 720/840/1020/1140 Dimensions (H x W x D) 333x1150x245 Weight kg 18 Included Condensate Pump No Drain Diameter (ext) φ20 Power Input w 40 Power supply 230V / 1Ph / 50Hz Recoended fuse size 5 Remote Controller PC RT (PC RF infra-red and simplified model optional) * Four fan speeds only available with PC-RF wired controller or PC-LH3B infra-red controller OUTDOOR UNITS RS 3HVRNS3 Power supply 230V / 1Ph / 50Hz Noise level cooling (sound pressure) (night mode) (7) db() 48 (46) Noise level heating (sound pressure) (7) db() 50 Noise level (sound power) (8) db() 66 ir flow (Cooling / Heating) m 3 /h 2682 Dimensions (H x W x D) 600x792x300 Weight kg 44 Piping diameter (Liquid / Gas) Minimum Piping Length m 5 Maximum Piping Length / Height Difference m 50 / 30 Current Quantity of Refrigerant kg 1.90 Chargeless / dditional Refrigerant Charge m / g/m 20 / 30 Recoended fuse size 25 Starting current <10 Running current (cooling / heating) 10.0 / 8.8 Interconnecting Cables No. LNE + 2 core screened Working Range (cooling / heating) C -5ºC~43(db)ºC/ -20(wb)ºC~15(wb)ºC Refrigerant / GWP R410a / 1975 Compressor type Scroll System price includes PC-RT wired remote controller. (1) Nominal Cooling: Internal temperature 27 C db (19 C wb) - mbient 35 C (2) Nominal Heating: Internal temperature 20 C - mbient 7 C db (6 C wb) (3) UK Cooling: Internal Temperature 23 C db (16 C wb) - mbient 30 C (4) Data calculated in accordance to pren14825 and the Coission Counication 2012/C 172/01 (5) Nominal load efficiency (Cooling 35 C/27 C, Heating 7 C/20 C) (6) Sound pressure level is measured at 1.0m below the unit and 1.0m from the discharge louvre (Measured in an anechoic chamber) (7) Sound pressure level is measured at 1.0m from the unit front surface and 1.5m from floor level (Measured in an anechoic chamber) (8) Sound power level is the -weighted sound power level [db()] measured at standard rated conditions for the «cooling» mode operation in accordance to EN
5 Wall Mounted UTOPI IVX COMFORT PC RF RS 3HVNC1 RPK FSN(H)3M PC RT RS 4H(V)NC1E Indoor units Nominal cooling capacities 7.1kW to 10.0kW Nominal heating capacities 8.0kW to 11.2kW Low consumption motor Modern sleek design Ideal for offices and shops utomatic restart Easily accessible filters Built-in infra-red receiver. Remote controllers dvanced PC-RF wired LED 5 time ranges with different temperatures (reduced, weekly, holiday etc) Service menu and optional function menus, add your contact details to be shown when there is an error Standard PC-RT wired remote 4 prograable weekly schedules Service menu, optional function menu and fault diagnostic lternative option: infra-red or simplified remote control - see pages Outdoor units Compact design - single fan Fully ErP compliant with rated seasonal efficiency vailable in single phase and three phase RPK FSN(H)3M 42 More information on controls and options on pages
6 UTOPI IVX COMFORT Wall Mounted INDOOR UNITS RPK 3.0FSN3M RPK 4.0FSN3M Nominal Cooling Capacity (min - max) (1) kw 7.1 ( ) 10 ( ) Nominal Heating Capacity (min - max) (2) kw 8.0 ( ) 11.2 ( ) UK Cooling Capacity (sensible) (3) kw 7.7 (5.7) 10.6 (7.3) Seasonal Efficiency SEER (4) Seasonal Efficiency S (4) (verage Climate) Nominal Load Efficiency EER / (5) Energy Class (Cool/Heat) 2.69 / 2.93 D / D 2.15 / 3.15 G / D Noise Level (sound pressure) (L / M / H / H1*) (6) (SP-00) db() 36/40/43/49 41/46/49/51 Noise level (sound power) (8) (SP-00) db() ir flow cooling mode (L / M / H / H1*) m 3 /h 720/840/1020/ /1020/1140/1320 Dimensions (H x W x D) 333x1150x x1150x245 Weight kg Included Condensate Pump No No Drain Diameter (ext) φ20 φ20 Power Input w Power supply 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Recoended fuse size 5 5 Remote Controller PC RT (PC RF infra-red and simplified model optional) * Four fan speeds only available with PC-RF wired controller or PC-LH3B infra-red controller OUTDOOR UNITS RS 3HVNC1 RS 4H(V)NC1E Power supply 230V / 1Ph / 50Hz (230V / 1Ph / 50Hz) - 400V / 3Ph / 50Hz Noise level cooling (sound pressure) (night mode) (7) db() 48 (46) 52 (50) Noise level heating (sound pressure) (7) db() Noise level (sound power) (8) db() ir flow (Cooling / Heating) m 3 /h Dimensions (H x W x D) 600 x 792 x x 950 x 370 Weight kg Piping diameter (Liquid / Gas) Minimum Piping Length m 5 5 Maximum Piping Length / Height Difference m 50 / / 30 Current Quantity of Refrigerant kg Chargeless / dditional Refrigerant Charge m / g/m 20 / / 40 Recoended fuse size - 1Ph/3Ph 20/- 32/16 Starting current - 1Ph/3Ph <10 <10 Running current (cooling / heating) 1Ph (3Ph) 9.4/8.3 (-/-) 11.2/10.1 (4.1/3.7) Interconnecting Cables No. LNE + 2 core screened Working Range (cooling / heating) C -5ºC~46(db)ºC/ -20(wb)ºC~15(wb)ºC Refrigerant / GWP R410a / 1975 R410a / 1975 Compressor type Scroll Scroll System price includes PC-RT wired remote controller. (1) Nominal Cooling: Internal temperature 27 C db (19 C wb) - mbient 35 C (2) Nominal Heating: Internal temperature 20 C - mbient 7 C db (6 C wb) (3) UK Cooling: Internal Temperature 23 C db (16 C wb) - mbient 30 C (4) Data calculated in accordance to pren14825 and the Coission Counication 2012/C 172/01 (5) Nominal load efficiency (Cooling 35 C/27 C, Heating 7 C/20 C) (6) Sound pressure level is measured at 1.0m below the unit and 1.0m from the discharge louvre (Measured in an anechoic chamber) (7) Sound pressure level is measured at 1.0m from the unit front surface and 1.5m from floor level (Measured in an anechoic chamber) (8) Sound power level is the -weighted sound power level [db()] measured at standard rated conditions for the «cooling» mode operation in accordance to EN
7 Wall Mounted UTOPI IVX PREMIUM RS 2-2.5HVNP1 PC RF RPK FSN(H)3M Indoor units Nominal cooling capacities 5.0kW to 10.0kW Nominal heating capacities 5.6kW to 11.2kW Low consumption motor Ideal for offices and shops utomatic restart Easily accessible filters Built-in infra-red receiver. PC RT Remote controllers dvanced PC-RF wired LED 5 time ranges with different temperatures (reduced, weekly, holiday etc) Service menu and optional function menus, add your contact details to be shown when there is an error Standard PC-RT wired remote 4 prograable weekly schedules Service menu, optional function menu and fault diagnostic lternative option: infra-red or simplified remote control - see pages RS 3HVNP1E Outdoor units RS 4H(V)NP1E New DC inverter compressor for improved low-speed and part-load seasonal performance S of up to rating and SEER of up to rating djust temperature settings according to occupancy and external environmental conditions to save on energy. RPK FSN(H)3M 44 More information on controls and options on pages
8 UTOPI IVX PREMIUM Wall Mounted INDOOR UNITS RPK 2.0FSN3M RPK 2.5FSN3M RPK 3.0FSN3M RPK 4.0FSN3M Nominal Cooling Capacity (min - max) (1) kw 5.00 ( ) 5.60 ( ) 7.1 ( ) 10 ( ) Nominal Heating Capacity (min - max) (2) kw 5.60 ( ) 6.30 ( ) 8.0 ( ) 11.2 ( ) UK Cooling Capacity (sensible) (3) kw 5.3 (3.7) 5.9 (4.2) 7.7 (5.7) 10.6 (7.3) Seasonal Efficiency SEER (4) Seasonal Efficiency S (4) (verage Climate) Nominal Load Efficiency EER / (5) Energy Class (Cool/Heat) 2.92 / 3.21 C / C 2.97 / 3.16 C / D 3.32 / 3.37 / C 3.64 / 3.44 / B Noise Level (sound pressure) (L / M / H / H1*) (6) db() 33/38/40/42 36/40/43/49 36/40/43/49 41/46/49/51 Noise level (sound power) db() ir flow cooling mode (L / M / H / H1*) m 3 /h 600/780/840/ /840/1020/ /840/1020/ /1020/1140/1320 Dimensions (H x W x D) 333x1150x x1150x x1150x x1150x245 Weight kg Included Condensate Pump No No No No Drain Diameter (ext) φ20 φ20 φ20 φ20 1/4 / 5/ / Power Input w Power supply 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Recoended fuse size Remote Controller Wired PC RF (simplified, PC RT and infra-red models are optional) * Four fan speeds only available with PC-RF wired controller or PC-LH3B infra-red controller OUTDOOR UNITS RS 2HVNP1 RS 2.5HVNP1 RS 3HVNP1 RS 4H(V)NP1E Power supply 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz (230V / 1Ph / 50Hz) 400V / 3Ph / 50Hz Noise level cooling (sound pressure) (night mode) (7) db() 44 (42) 45 (43) 46 (42) 47 (43) Noise level heating (sound pressure) (7) db() Noise level (sound power) (8) db() ir flow (Cooling / Heating) m 3 /h Dimensions (H x W x D) 600 x 792 x x 792 x x 950 x x 950 x 370 Weight kg Piping diameter (Liquid / Gas) 6.35 / / 12.7 Minimum Piping Length m Maximum Piping Length / Height Difference m 50 / / / / 30 Current Quantity of Refrigerant kg Chargeless / dditional Refrigerant Charge m / g/m 30 / / / / 60 Recoended fuse size - 1Ph/3Ph 16/- 20/- 20/- 32/16 Starting current (1Ph/3Ph) <10 <10 <10 <10 Running current (cooling / heating) 1Ph (3Ph) 5.1/ / / /3.2 (8.7/8.9) Interconnecting Cables No. LNE + 2 core screened Working Range (cooling / heating) C -5ºC~46(db)ºC/ -20(wb)ºC~15(wb)ºC Refrigerant / GWP R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 Compressor type Scroll Scroll Rotary Scroll System Price (1Ph) System Price (3Ph) System price includes PC-RT wired remote controller. (1) Nominal Cooling: Internal temperature 27 C db (19 C wb) - mbient 35 C (2) Nominal Heating: Internal temperature 20 C - mbient 7 C db (6 C wb) (3) UK Cooling: Internal Temperature 23 C db (16 C wb) - mbient 30 C (4) Data calculated in accordance to pren14825 and the Coission Counication 2012/C 172/01 (5) Nominal load efficiency (Cooling 35 C/27 C, Heating 7 C/20 C) (6) Sound pressure level is measured at 1.0m below the unit and 1.0m from the discharge louvre (Measured in an anechoic chamber) (7) Sound pressure level is measured at 1.0m from the unit front surface and 1.5m from floor level (Measured in an anechoic chamber) (8) Sound power level is the -weighted sound power level [db()] measured at standard rated conditions for the «cooling» mode operation in accordance to EN
9 Indoor Units UTOPI IVX WLL MOUNTED RPK 0.8FSN3M RPK 1.0FSN3M RPK 1.5 (1.3)FSN3M RPK 1.5FSN3M RPK 2.0 (1.8)FSN3M Nominal Cooling Capacity (1) kw Nominal Heating Capacity (2) kw UK Cooling Capacity (sensible) (3) kw 2.1 (1.5) 2.6 (1.9) 3.2 (2.3) 3.7 (3.0) 4.3 (3.1) Noise Level (sound pressure) (L / M / H / H2) (4)(5) db() 30/32/35/39 30/32/35/39 33/36/40/46 33/36/40/46 33/38/40/42 Noise level (sound power) (6) db() ir flow cooling mode (L / M / H / H2) (5) m 3 /h 390/420/480/ /420/480/ /540/660/ /540/660/ /780/840/900 Dimensions (H x W x D) 300x790x x790x x790x x790x x1150x245 Weight kg Included Condensate Pump no no no no no Drain Diameter (ext) φ16 φ16 φ16 φ16 φ16 1/4 / 5/ / Power Input W Power supply 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Recoended fuse size RPK 2.0FSN3M RPK 2.5 (2.3)FSN3M RPK 2.5FSN3M RPK 3.0FSN3M RPK 4.0FSN3M Nominal Cooling Capacity (1) kw Nominal Heating Capacity (2) kw UK Cooling Capacity (sensible) (3) kw 5.3 (3.8) 5.5 (4.1) 5.9 (4.4) 7.7 (5.9) 10.6 (7.5) Noise Level (sound pressure) (L / M / H / H2) (4)(5) db() 33/38/40/42 36/40/43/49 36/40/43/49 36/40/43/49 41/46/49/51 Noise level (sound power) (6) db() ir flow cooling mode (L / M / H / H2) (5) m 3 /h 600/780/840/ /840/1020/ /840/1020/ /840/1020/ /1020/1140/1320 Dimensions (H x W x D) 333x1150x x1150x x1150x x1150x x1150x245 Weight kg Included Condensate Pump no no no no no Drain Diameter (ext) φ16 φ16 φ16 φ16 φ16 1/4 / 5/ / Power Input W Power supply 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Recoended fuse size (1) Cooling: Internal ambient 27 C db (19 C wb) - mbient 35 C (2) Heating: Internal ambient 20 C - mbient 7 C db (6 C wb) (3) UK Cooling: Internal Temperature 23 C db (16 C wb) - mbient 30 C (4) Sound pressure level measured at 1 m below the unit, 1 m from the discharge louvre (measured in anechoic room) (5) Four fan speeds only available with PC-RF wired controller or PC-LH3B infra-red controller (6) Sound power level is the -weighted sound power level [db()] measured at standard rated conditions for the «cooling» mode operation in accordance to EN12102 FLOOR MOUNTED CSED Ref. RPF 1.0 (0.8)FSN2E RPF 1.0FSN2E RPF 1.5 (1.3)FSN2E RPF 1.5FSN2E Nominal Cooling Capacity (1) kw Nominal Heating Capacity (2) kw UK Cooling Capacity (sensible) (3) kw 2.1 (1.5) 2.6 (1.9) 3.2 (2.3) 3.7 (2.7) Noise Level (sound pressure) (L / M / H) (4) db() 29/32/35 29/32/35 31/35/38 31/35/38 Noise level (sound power) (5) db() ir flow cooling mode (L / M / H) m 3 /h 360/420/ /420/ /600/ /600/720 Dimensions (H x W x D) 630x1045x x1045x x1170x x1170x220 Weight kg Included Condensate Pump no no no no Drain Diameter (ext) φ18.5 φ18.5 φ18.5 φ18.5 Power Input W Power supply 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Recoended fuse size
10 Set Free WLL MOUNTED RPK 0.6-1FSN3M RPK 1.5FSN3M RPK 2-4FSN3M Integrated infra-red receiver and automatic restart Easily accessible filters New multi-function graphical remote control (see page 262) PC RF WLL MOUNTED RPK 0.6FSN(H)3M RPK 0.8FSN(H)3M RPK 1.0FSN(H)3M RPK 1.5 (1.3)FSN(H)3M RPK 1.5FSN(H)3M Nominal Cooling Capacity (1) kw Nominal Heating Capacity (2) kw UK Cooling Capacity (sensible) (3) kw 1.5 (1.4) 2.1 (1.9) 2.6 (2.0) 3.4 (2.8) 3.9 (3.2) Noise Level (sound pressure) (L / M / H / H2) (4) db() 29/31/32/35 30/32/35/39 30/32/35/39 33/36/40/46 33/36/40/46 Noise level (sound power) db() ir flow cooling mode (L / M / H / H2) (5) m 3 /h 360/420/450/ /420/480/ /420/480/ /540/660/ /540/660/840 Dimensions (H x W x D) 300 x 790 x x 790 x x 790 x x 790 x x 790 x 230 Weight kg Included Condensate Pump no no no no no Drain Diameter (ext) φ16 φ16 φ16 φ16 φ16 Power Input W Power supply 230V / 1Ph / 50Hz Recoended fuse size RPK 2.0 (1.8)FSN3M RPK 2.0FSN3M RPK 2.5 (2.3)FSN3M RPK 2.5FSN3M RPK 3.0FSN3M RPK 4.0FSN3M Nominal Cooling Capacity (1) kw Nominal Heating Capacity (2) kw UK Cooling Capacity (sensible) (3) kw 4.5 (3.2) 5.2 (3.7) 6.2 (4.6) 6.4 (4.7) 7.5 ( (7.5) Noise Level (sound pressure) (L / M / H / H2) (4) db() 33/38/40/42 33/38/40/42 36/40/43/49 36/40/43/49 36/40/43/49 41/46/49/51 Noise level (sound power) db() ir flow cooling mode (L / M / H / H2) (5) m 3 /h 600/780/840/ /780/840/ /840/1020/ /840/1020/ /840/1020/ /1020/1140/1320 Dimensions (H x W x D) 333 x 1150 x x 1150 x x 1150 x x 1150 x x 1150 x x 1150 x 245 Weight kg Included Condensate Pump no no no no no no Drain Diameter (ext) φ16 φ16 φ16 φ16 φ16 φ16 1/4 / 5/8 1/4 / 5/ / / Power Input W Power supply 230V / 1Ph / 50Hz Recoended fuse size (1) Cooling: Internal ambient 27 C db (19 C wb) - mbient 35 C (2) Heating: Internal ambient 20 C - mbient 7 C db (6 C wb) (3) UK Cooling: Internal Temperature 23 C db (16 C wb) - mbient 30 C (4) Sound pressure level measured at 1.0 metres below the unit and 1.0m from the air inlet (measured in anechoic room) (5) 4 step fan speed only available with PC-RF remote controller 188 More information on controls and options on pages
Wall Mounted. More information on controls and options on pages
Wall Mounted 28 More information on controls and options on pages 255-270 WALL MOUNTED Hitachi offers a wide range of stylish and highly-efficient wall mounted systems suitable for a variety of applications.
More informationWall Mounted. More information on controls and options on pages
Wall Mounted 28 More information on controls and options on pages 255-270 WALL MOUNTED Hitachi offers a wide range of stylish and highly-efficient wall mounted systems suitable for a variety of applications.
More informationCassette. More information on controls and options on pages
Cassette 68 More information on controls and options on pages 257-272 CSSETTE Hitachi s cassettes are an efficient, economical and discrete solution for all commercial spaces, including shops and offices.
More informationHitachi Air Conditioning. Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE
Hitachi Air Conditioning Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE Set Free VRF Systems Mini 2-pipe S i d e fl o w2 - p i p e Modular 2 or 3-pipe Std - Efficiency Hi-Efficiency
More informationHitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE
Hitachi Air Conditioning Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Product Range Room Air Conditioners (kw) 2.0 2.5 3.5 5.0 6.0 7.1 8.0 9.0 10.0 Wall Mounted Summit SCOP 4.4 Wall
More informationA GUIDE TO COMFORT EXCLUSIVELY DISTRIBUTED BY TEMPERZONE AUSTRALIA
A GUIDE TO COMFORT HITACHI INVERTER SPLIT SYSTEMS Enjoy the Silence with Quiet Mode With Hitachi, noisy air conditioners are a thing of the past. Our modern Full Flat design has ensured efficient yet ultra-quiet
More informationHeat Pump Air Conditioning Systems
Heat Pump Air Conditioning Systems Create your own Utopia. In a climate as diverse as ours air conditioning your premises can make a huge difference to the comfort of your staff, and your customers too.
More informationTECHNICAL CATALOG HITACHI INVERTER-DRIVEN SPLIT SYSTEM HEAT PUMP AIR CONDITIONERS. - UTOPIA IVX Premium / IVX Standard - Technical Catalog.
TECHNICAL CATALOG HITACHI INVERTER-DRIVEN SPLIT SYSTEM HEAT PUMP AIR CDITIERS - UTOPIA IVX Premium / IVX Standard - Technical Catalog Models < Outdoor Units > RAS-2HVNP RAS-2.5HVNP RAS-3HVNC General index
More informationMidea Ducted and Cassette Split Systems. Maximum versatility, maximum value.
Midea Ducted and Cassette Split Systems Maximum versatility, maximum value. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.
More informationUTOPIA RASC-IVX SERIES RASC-H(V)RNME. Technical Catalogue RASC-5HVRNME RASC-10HRNME
UTOPIA RASC-IVX SERIES RASC-H(V)RNME Technical Catalogue RASC-5HVRNME RASC-10HRNME Contents C o n t e n t s General information Features and benefits General data Capacities and selection data Acoustic
More information50A KP 70A KP 90A KP 120A KP 150A KP 210A
DC inverter all in one Model KP 5A KP 7A KP 9A KP 12A KP 15A KP 21A Power supply V/Hz/Ph 23/5/1 23/5/1 23/5/1 23/5/1 38/5/3 38/5/3 Nominal heating capacity kw 5 7 9 12 15 21 Nominal cooling capacity kw
More informationTechnical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw
Underceiling/Console Split System Air Conditioners Technical Data ISU Series Featuring SAT- Controller & Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 13. kw 15 kw NOVEMBER 0 ISU SERIES
More informationWall Split System Air Conditioning
Wall Split System Air Conditioning Comfort you can depend on. The perfect combination of stylish good looks and efficient performance. These systems are designed to keep you comfortable all year round.
More informationMidea Ducted and Cassette Split Systems. Year round comfort, all around the house.
Midea Ducted and Cassette Split Systems Year round comfort, all around the house. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.
More informationTECHNICAL CATALOGUE MONO SPLIT RAK-25PSC RAK-35PSC RAC-35WSC
TECHNICAL CATALOGUE MONO SPLIT RAK-18PSC RAK-25PSC RAK-35PSC RAC-18WSC RAC-25WSC RAC-35WSC HITACHI Specifications in this catalogue are subject to change without prior notice in order for HITACHI to bring
More informationDucted inverter reverse cycle air conditioning
Ducted inverter reverse cycle air conditioning What is ducted inverter reverse cycle air conditioning? Ducted inverter reverse cycle air conditioning is an ideal solution for whole-of-home or office cooling
More informationAURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS
AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS Aurora Wall Split Systems. Built for one of the harshest climates on Earth. Aurora Wall Split Systems The leading Australian owned air conditioning
More informationStandard Inverters FUNCTION COMFORTABLE AIR FLOW CONVENIENT & ECONOMY MAINTENANCE & PREVENTION OTHERS
Standard Inverters SRK-ZJ (2.5-5.0 kw) Packed with features and the latest technologies in room air conditioning, the SRK Standard Inverter range offers energy efficient cooling and heating for individual
More informationV D M. Zwembaden. Max: +32 (0)495/
M: +32 (0)495/790.892. www.dms.be m@dms.be Compared to regular heat pumps, inverter driven pumps automatically optimise the refrigerant flow rate by varying the speed of both the fan and the compressor.
More informationModels FSVN FSN FXN KW. set. free. Variable refrigerant flow air conditioning systems R410A
Models FSVN FSN FXN 8.0 85.0 KW SET FREE VRF set free R410A Variable refrigerant flow air conditioning systems Contents Company profile 4 Product range overview 6 Features and benefits 8 Indoor units 12
More informationSingle Zone Air Conditioner SVC MANUAL (Exploded View)
Single Zone Air Conditioner SVC MANUAL (Exploded View) CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel. MODEL: MR36UY3J 960-920-10
More informationQ Series. Inverter Split Systems
Q Series Inverter Split Systems Creating comfort in the home. Australians have been enjoying the comfort, convenience and reliability of Rinnai household appliances in their homes for over 40 years. Our
More informationCMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N
E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,
More informationJanuary Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC
January 2018 Engineering Data RXSQ24-60TAVJU Heat Pump 208/230V / 60 Hz / 1 ph Presales Manual DAIKIN NORTH AMERICA LLC DAIKIN NORTH AMERICA LLC RXSQ_TAVJU VRV LIFE TM Heat Pump Unit Contents 1. Features
More informationMulti Inverter Air Conditioning Condensing Units - Summary
Multi Inverter Air Conditioning Condensing Units - Summary Model Description Nominal Max of Cooling Inverter No. Heating of (kw) Fan Condensing (kw) Coils Unit ECO18MS2 Twin Multi Inverter 5kW 5.2 6.1
More information> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories
> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION Available range Unit type IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS Versions (heat recovery) VB Base
More informationMidea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual
Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without
More informationSubmittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System
Submittal Data: Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES
More informationSUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP
VEP075N432G Job Name: Location: Schedule No.: System Designation: Engineer: Architect: Date: For: Reference Approval Review Construction FEATURES Two-pipe heat pump Access to electrical box for ease of
More informationInnovative air conditioning
Innovative air conditioning No external condensers or pipework Easy installation Discreet external grilles Quiet, high efficiency operation In exclusive partnership with Olimpia Splendid, one of Europe
More informationSubmittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System
Submittal Data: Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Compact and Quiet Design -High Efficiency DC Inverter Technology -Wireless Remote
More informationSubmittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To
Submittal Data: Innovative Ductless solutions 12,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES
More informationWhole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.
Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 1984 saw Advanced Australia Fair become
More informationSubmittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To
Submittal Data: Innovative Ductless solutions 24,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES
More informationWhole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.
Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 1984 saw Advanced Australia Fair become
More informationTECHNICAL CATALOGUE MONO SPLIT RAK-18PED RAC-18WED RAC-25WED RAC-35WED RAC-X10/14EAG RAC-L10/14EAG RAC-M25/35EAG
TECHNICAL CATALOGUE MONO SPLIT RAK-18PED RAK-25PED/25PEDC RAK-35PED/35PEDC RAK-50PED/50PEDC RAS- X10/14/18EAG RAS-L10/14EAG RAS-M25/35/50EAG RAC-18WED RAC-25WED RAC-35WED RAC-X10/14EAG RAC-L10/14EAG RAC-M25/35EAG
More informationTCGB0077_v0_11_2012_CS4.indb 1 21/12/ :27:02
TCGB0077_v0_11_2012_CS4.indb 1 21/12/2012 14:27:02 TCGB0077_v0_11_2012_CS4.indb 2 21/12/2012 14:27:02 Index I n d e x General information Features and benefits General data Capacities and selection data
More informationLaunching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-
Suary PAGE: 1 / 47 1 This Technical Bulletin introduces the new outdoor units of the SET-FREE FSXN1E Series (8 to 54HP) using R410A. 2 The details are indicated in the description. Index 1. Main concepts...
More informationAURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS
AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS Aurora Wall Split Systems. Built for one of the harshest climates on Earth. Aurora Wall Split Systems The leading Australian owned air conditioning
More information2 &3-4 Head Multi System
2 &3-4 Head Multi System INVERTER 2 &3-4 ROOM Multi System The Fujitsu Inverter Multi System has been designed with flexibility in mind. With the introduction of indoor units in a range of capacities and
More informationAURA SERIES 9000 BTU BTU BTU BTU LETO SERIES 9000 BTU BTU BTU BTU
AURA SERIES 9000 BTU 12000 BTU 18000 BTU 24000 BTU LETO SERIES 9000 BTU 12000 BTU 18000 BTU 24000 BTU Energy Star Efficiency The Aura Series by Senville enjoys certifications by Energy Star, meaning that
More informationTechnical Guide. Multizone: Multi-Split Type Heat Pump Systems
Technical Guide Multizone: Multi-Split Type Heat Pump Systems 1 Another Hitachi Day 1 Wall Mounted (RAK) Imagine choosing your perfect day then instantly creating it in the comfort of your own home. With
More informationWhole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.
Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 198 saw Advanced Australia Fair become
More informationDo you want a versatile solution
Do you want a versatile solution to make significant savings? ESTIA TOSHIBA AIR CONDITIONING RESIDENTIAL HEATING AIR-TO-WATER HEAT PUMP ESTIA hatever you need ESTIA TO MAKE SIGNIFICANT SAVINGS Toshiba
More informationFTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR
FTQ SERIES DUCTED HEAT PUMP SYSTEMS INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR FTQ SERIES DUCTED HEAT PUMP SYSTEMS LEADING TECHNICAL PERFORMANCE
More informationJust feel well. 2017/2018 Air conditioning
1947-20 17 2017/2018 Air conditioning Unique solutions 40 Unique and advanced design for vertical or horizontal installation VERTICAL INSTALLATION q Vertical installation with compact dimensions, only
More informationturn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES
turn to the experts SM R 410A DC INVERTER LIGHT COMMERCIAL SERIES DC Inverter Technology More Economical Energy Efficient Once indoor air temperatures reach your desired levels, inverter driven air-conditioners
More informationINVERTER DUCTED SYSTEMS
INVERTER DUCTED SYSTEMS What you ll find inside: DC Twin-Rotary Compressor Inverter Ducted advantages Controllers Product Specifications Energy Efficient Powerful Operation Flexible Application 1 About
More informationMarket District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems
Market District Commons Black Oak Engineering Daikin Ductless Heat Pump Split Systems N/A N/A M001 Plans Fujitsu ductless heat pump systems 353 Rte. 46 West Fairfield, NJ Fujitsu Fujitsu Halcyon 07004
More informationEnergy-saving operation
DC Inverter can attain both comfort a Energy-saving operation All the models of Panasonic FS Inverter Series are equipped with DC inverters for the higher EER operation. The new design attains quiet and
More informationMidea VRF (V4+) V4+S (Heat Pump) V4+i (Individual) (Heat Pump) V4+R (Heat Recovery) MVRF 05/15
Midea VRF (V+) V+S (Heat Pump) V+i (Individual) (Heat Pump) V+R (Heat Recovery) MVRF 05/5 Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit
More informationBraemar superior range of reverse cycle air conditioning
Braemar superior range of reverse cycle air conditioning Frank Seeley AM FAICD Founder and Executive Chairman. For more than 40 years, Seeley International has been creating world leading air conditioning
More information360 round flow, ensuring uniform airflow distribution across the room. Independent louvre control allows each louvre to be set at the desired angle
AUTO ILLE ELEVATION GR ED CAN BE LOWER UP TO 4M Better Design Super slim design, perfect for tight roof spaces 360 round flow, ensuring uniform airflow distribution across the room Independent louvre control
More informationInverter Ducted Air Conditioners
Inverter Ducted Air Conditioners About Carrier inverter ducted systems Carrier s Inverter Ducted systems allows you to air condition your home without having to install the indoor units on your wall, making
More information2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating
2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER AIR-TO-WATER HEAT PUMP cooling - heating MINI CHILLER Highly efficient heat pump for summer and winter air conditioning. Ideal for residential and commercial
More informationCMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL
CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years
More informationMonozone/Multizone (NH5, QH5) Summit (YH5) Bigflow (G4, GH4) Technical Catalogue
Monozone/Multizone (NH5, QH5) Summit (YH5) Bigflow (G4, GH4) Technical Catalogue Monozone/Multizone Outdoor Unit RAC RAM Monozone/Mutizone Indoor Unit RAK RAF RAI RAD Summit and Bigflow RAS/RAC HITACHI
More informationPower Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.
Submittal Data: CROWN09HP230V1B Superior Performance in Extreme Temperature 9,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule
More informationAir Cooled Packaged Systems AIRAH Back to Basics
Air Cooled Packaged Systems AIRAH Back to Basics What s changed? New Refrigerants R410a MEPS EER / AEER / SEER Manufacturing Technologies Research, Development and Testing New technologies, controls, reliability
More informationCommercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF
2016 Commercial Air Conditioners VRF 60Hz V4+SV4+RV4+WMini VRF OUTDOOR UNIT LINEUP INDOOR UNIT LINEUP 1.8 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 10.0 11.2 12.5 14.0 16.0 20.0 25.0 28.0 40.0 45.0 OUTDOOR UNIT
More informationHEAT PUMPS SiOS SYSTEM TERMINAL UNITS UNICO FIXED AIR CONDITIONERS PORTABLE AIR CONDITIONER AIR COOLER VMC DEHUMIDIFIERS HUMIDIFIERS
136 PORTABLE AIR FIXED AIR UNICO AIR COOLER SYSTEM TERMINAL UNITS HEAT PUMPS SiOS FIXED AIR S 137 PELLET STOVES GAS STOVES VMC DEHUMIDIFIERS HUMIDIFIERS FAN HEATERS CERAMIC FAN HEATERS PERSONAL COMFORT
More informationMODULAR CHILLER. R410a R22
Ra R 3 Ra/-0 R/-0 New ppearance New Y-shape design, more fashion IR-COOLED SERIES (Ra) Compressor ir cooling side heat exchanger Best scroll compressor, low sound power level, By using calculation model
More informationSHORAI. hatever you need. Do you want to improve your quality of life?
Do you want to improve your quality of life? SHORAI TOSHIBA AIR CONDITIONING RESIDENTIAL SOLUTIONS HIGH WALL INDOOR INVERTER UNIT SHORAI hatever you need SHORAI IMPROVE YOUR QUALITY OF LIFE EFFICIENCY
More informationThe latest innovation in cool 7 YEAR 1 YEAR WARRANTY ON PARTS WARRANTY ON COMPRESSORS
The latest innovation in cool 7 YEAR WARRANTY ON COMPRESSORS 1 YEAR WARRANTY ON PARTS Engineered to be both aesthetically pleasing and energy-efficient, Katashi air conditioning units bring the latest
More informationMEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil
Ducted Packaged Roof Top Air Conditioners Product Review OPA-RK Series Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 10.6 kw 137 kw MEPS COMPLIANT INVERTER MODEL MODELS MARCH 2014
More informationTechnology that works fast. Inverter Ducted Systems
Technology that works fast Inverter Ducted Systems About Toshiba s Inverter Ducted systems. Toshiba s Inverter Ducted systems allows you to air condition your home without having to install the indoor
More informationTechnology that works fast. Inverter Ducted Systems
Technology that works fast Inverter Ducted Systems About Toshiba s Inverter Ducted systems. Toshiba s Inverter Ducted systems allows you to air condition your home without having to install the indoor
More informationTechnology that works fast. Inverter Ducted Systems
Technology that works fast Ducted Systems About Toshiba s Ducted systems. Combining high power with high efficiency. Toshiba s Ducted systems allows you to air The Toshiba Air Conditioning DC Hybrid. The
More informationProduct Line Introduction. Karl Zhang Technical support engineer
Product Line Introduction Karl Zhang Technical support engineer Air Conditioning Solutions Heating & Hot Water Solutions Control Solutions Air Conditioning Solutions Residential Application Commercial
More informationBENEFITS. Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056
1.5-Ton Wall Mounted Unit FAQ18PVJURZQ18PVJU9 FEATURES Maximum piping length up to 164 ft. allows flexible placement of indoor unit Maximum piping height separation up to 98 ft. Low ambient cooling operation
More informationAir / Water Heat Pump - Compact Design Modulating 8 18 kw
Air Ground Water Air / Water Heat Pump - Compact Design Modulating 8 18 kw Heliotherm Sensor Comfort Compact A modulating air / water heat pump in compact design for outdoor installation for generous sized
More informationSERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC
Revision A: MUZ-HM09/12NA- U8, MUZ-HM09/12NA2- U8, MUZ-HM15/18NA- U1, MUZ-HM15/18NA2- U1 and MUZ-HM24NA2- U1 have been added. Please void OBH747. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A.
More informationMANUAL DE INGENIERIA. Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30
MANUAL DE INGENIERIA Evaporadora Sopladora 'MVA' con Condensadora 'MOV' - Blue Star Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30 Part 1 General Information 1. Model
More informationOLIMPIA SPLENDID S INVERTER DC TECHNOLOGY 100% 80% 70% DC INVERTER AC INVERTER NON INVERTER
SHERP ir-water heat pump COP > 4 DHW 60 C Energy class ErP (1) : RENEWLE TECHNOLOGIES Sherpa uses the heat in the air, and transfers it to system terminals in an efficient manner. For each kw of electricity
More informationLeading edge reverse cycle air conditioning. Ducted and ceiling cassette
Leading edge reverse cycle air conditioning Ducted and ceiling cassette Seeley International never stops striving to innovate and build the world s most energy efficient heaters and air conditioners. The
More informationAIR CONDITIONERS & HEAT PUMPS CATALOGUE. Multi Zones Series BTU BTU BTU. AURA Series 9000 BTU BTU BTU BTU
AIR CONDITIONERS & HEAT PUMPS CATALOGUE AURA Series 9000 BTU 12000 BTU 18000 BTU 24000 BTU Multi Zones Series 18000 BTU 28000 BTU 36000 BTU LETO Series 9000 BTU 12000 BTU 18000 BTU 22000BTU For over 10
More informationAir Conditioning Catalogue. RAC Room Air Conditioning
Air Conditioning 2015 Catalogue RAC Room Air Conditioning www.hitachi.com 2015 Catalogue RAC This is Hitachi page 04 ErP design page 08 Technology page 10 Products RAC Mono page 15 RAC Multi page 35 Product
More informationVARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG
VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG Spring 2017 Edition BRYANT VRF ADVANTAGES IT TAKES an Efficient Solution...1 What is Variable Refrigerant Flow (VRF)...1 Simultaneous Heating & Cooling...1
More informationUltimate VRF System R410A, 50Hz
Ultimate VRF System R410A, 50Hz TVR WIZ Systems, a new leap in technology and innovation A proven solution from a trusted advisor Trane is proud to present their new line of variable refrigerant systems,
More informationSET FREE SERIES FSNM(E)
SET FREE SERIES FSNM(E) Outdoor Units:8~12 HP Specifications in this manual are subject to change without notice in order that HITACHI may bring the latest innovations to their customers. Whilst every
More informationP-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP
P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP www.mitsubishielectric.ca P-SERIES The Attraction of Being Untraditional Mr. Slim P-Series is the ductless solution for demanding environments that
More informationGeniuses at work. Residential Mini Splits
Residential Mini Splits Smart Pearl Smart Whisper Geniuses at work. Two smart ways to heat and cool your home. Be the smartest person in the room when you get your home equipped with a Wi-Fi enabled heat
More informationJUNE & 3-4 Head Multi System
JUNE 2008 2 & 3-4 Head Multi System INVERTER 2 &3-4 ROOM Multi System The Fujitsu Inverter Multi System has been designed with flexibility in mind. With the introduction of indoor units in a range of capacities
More informationReverse Cycle Split Systems DC Inverter & Fixed Speed
Reverse Cycle Split Systems DC Inverter & Fixed Speed Think of the biggest air conditioning brands in Australia. Well, Midea is bigger than any of them - in fact it s probably bigger than all of them put
More informationAIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw
COMFORT HEAT PUMPS AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw climaveneta.com COMFORT HEAT PUMPS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air to water heat pump for outdoor installation,
More informationWall Mounted Air Conditioner
Mu ti S it ho ous So utions Wall Mounted Air Conditioner 1hr off timer Weekly Timer System ler Filter sign Auto Restart Fresh Air intake Branch Extension Drain Pump Low Ambient Elect.Valve ODP0 Refrigerant
More informationAir Conditioner SVC MANUAL(Exploded View)
Internal Use Only http://biz.lgservice.com Air Conditioner SVC MANUAL(Exploded View) Type : Ceiling Concealed Duct MODEL : AMNW24GBGA0 [LMHN240HV] AMNW36GBGA0 [LMHN360HV] CAUTION Before Servicing the unit,
More informationDuctless Split Systems Wall-mounted, Single Zone Heat Pump
Ductless Split Systems Wall-mounted, Single Zone Heat Pump PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H
More informationPRODUCT DOCUMENTATION
Thermal Management for Business-Critical Continuity Liebert HPS High Performance Split ir Conditioner for Mobile Network ccess Nodes HPSE SE_W HPSC Liebert HPS - PD - 272965-29.07.2013 PRODUCT DOCUMENTTION
More informationAir-cooled modular Chiller. Nick Technical Engineer
Air-cooled modular Chiller Nick Technical Engineer Product line-up Features Roadmap Product range New product Comparison Reference project Product roadmap Entered air cooled modular chiller market T1/T3
More informationHistory List. Version Date Update Information New EHS SPLIT TDB Released. (Modify the Spec Note)
History List Version Date Update Information 1.0 15.02.27-2015 New EHS SPLIT TDB Released. (Modify the Spec Note) 1.1 15.03.06 1.2 15.04.06 - Modify : Note(Spec, Capacity Table) / Electric Diagram / OD
More informationNEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER
NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER FTQ SERIES HEATING AND COOLING SYSTEMS MULTI-POSITIONAL AIR HANDLER Up to
More informationSERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A
Revision B: MUZ-GL09NA- U8 and MUZ-GL09NAH- U8 have been added. Please void OBH733 REVISED EDITION-A. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH733 REVISED EDITION-B Models MUZ-GL09NA
More informationSHERPA. Air-water split heat pump. COP > 4 ACS a 60 C
Air-water split heat pump. COP > 4 ACS a 60 C Energy class: 35 55 RENEWALE TECHNOLOGIES Sherpa uses the heat in the air, and transfers it to system terminals in an efficient manner. For each kw of electricity
More informationEREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY
Easy and fast installation Hydronic module available Compact, reliable and efficient Nominal cooling capacity : 8-40 kw Nominal heating capacity : 17-40 kw 50 410A Cooling or heating USE The air-to-water
More informationAIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw
COMFORT CHILLERS AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com COMFORT CHILLERS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air-cooled liquid chiller for outside installation
More informationAir to air heat pump range. Why Vaillant? because there is something in the air.
Air to air heat pump range Why Vaillant? because there is something in the air. climavair plus climavair exclusive Vaillant climavair air to air heat pump systems When it comes to creating the perfect
More informationHigh Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.
HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy
More informationVariable Refrigerant Flow
Variable Refrigerant Flow Two-pipe Heat Recovery and Heat Pump Systems Heat Recovery Single-chassis Design Heat Pump Modular Design Table of Contents Carrier VRF Advantages 2 Revolutionary Design 3 Advanced
More informationEngineering Data Manual
Engineering Data Manual Residential Split Low Silhuoette LSN DCI Inverter Series Indoor Units LSN 25 DCI LSN 35 DCI LSN 50 DCI LSN 60 DCI LSN 72 DCI Outdoor Units ONG 25 DCI ONG 35 DCI ONG 50 DCI GC 60
More information