Chargebuster Ion Gun Installation, Operation and Maintenance

Size: px
Start display at page:

Download "Chargebuster Ion Gun Installation, Operation and Maintenance"

Transcription

1 TECHNICAL BULLETIN TB-6559 Chargebuster Ion Gun Installation, Operation and Maintenance The Chargebuster Ion Gun reduces a static charge of ±1000 V down to ±100 V in less than one second at a distance of six inches (30-psi /0.2MPa inlet pressure). Refer to the ESD Association ANSI/ESD Standard STM3.1 for the test procedure. The offset voltage (balance) is within ±30 V of zero at a distance of six inches, significantly less than the required limits of < ±50 volts per ANSI/ESD S Figure 1. EMIT Chargebuster Ion Gun, 120V EMIT Chargebuster Ion Gun, 220V Description The EMIT 50645, Chargebuster Ion Gun is a Point-of-Use Ionizer. It uses compressed air or nitrogen to neutralize static charges in localized areas. Most companies address ElectroStatic Attraction, visual imperfections, and contamination issues by dislodging charged dust and debris with compressed air ionizers. There is sometimes a need to provide static control in a small defined area or location. This may be done to provide static control within production equipment, in mini-environments, or to facilitate particle removal from part of a product. Ionizers used for this purpose may be blow-off guns or nozzles that work with a supply of compressed air or nitrogen. They may use either nuclear, soft x-ray or any of the previously described types of corona ionization technology. It will be important to choose a method of ionization and cleanliness of the gas supply that is appropriate to the work area. (ESD handbook ESD TR20.20 section Point-Of-Use Ionization) The modular and ergonomic design includes an ESD protective flexible hose and is easily controlled by depressing the trigger. The EMIT 50645, Chargebuster Ion Gun meets or exceeds the required limits of ANSI/ESD S20.20 when tested in accordance with ANSI/ ESD S3.1 and ESD TR53. Compact and lightweight, the Chargebuster Ion Gun s console can be mounted anywhere on the workstation for easy access. The console connects to any supply of clean dry air or nitrogen, and an internal disposable filter collects residual particles, oil and moisture. The console, gun, and air hose are static-dissipative. The 7 foot hose allows for convenient neutralization of localized areas where desired. Necessary non-conductors in the environment cannot lose their electrostatic charge by attachment to ground. Ionization systems provide neutralization of charges on these necessary non-conductive items (circuit board materials and some device packages are examples of necessary non-conductors). Assessment of the ESD hazard created by electrostatic charges on the necessary nonconductors in the work place is required to ensure that appropriate actions are implemented, commensurate with risk to ESDS [ESD sensitive] items. (ANSI/ ESDS Foreword) The primary method of static charge control is direct connection to ground for conductors, static dissipative materials, and personnel. A complete static control program must also deal with isolated conductors that cannot be grounded, insulating materials (e.g., most common plastics), and moving personnel who cannot use wrist or heel straps or ESD control flooring and footwear. Air ionization is not a replacement for grounding methods. It is one component of a complete static control program. Ionizers are used when it is not possible to properly ground everything and as backup to other static control methods. In clean rooms, air ionization may be one of the few methods of static control available. (ESD Handbook TR20.20 Ionization, section ) Packaging 1 Chargebuster Ion Gun with Hose and Disposable Filter 1 Wall Transformer (24 1 A) 1 10 Cable 1 Mounting Plate 1 Quick Coupling 1 S-Hook 4 Screws 1 Certificate of Calibration 1 220V Power Supply with IEC Adapter (50644 only) Power cord must be purchased separately for the Use for Europe and for UK/Asia. Use replacement filter item # TB-6559 August 2009 Page 1 of 5

2 Features and Components B E A C D E. Disposable Filter Release / Lock Button: Push down to release the disposable filter and hose assembly from the console. This button should also click when properly attaching the disposable filter and hose assembly to the console. F. Disposable Filter: Filters particles, oil and moisture from the incoming air supply. Installation COMPRESSED GAS REQUIREMENTS NOTE: Failure to use clean dry air or nitrogen may result in damage to the Chargebuster Ion Gun that is not covered under the Limited Warranty. Figure 2: Gun and hose features and components GUN AND HOSE A. Hanging Clip: Use to hang the gun on an apparatus. May also be used with the included S-Hook. B. Status LED: Illuminates when the trigger is held down. Indicates when the gun is outputting ionized air. C. Nozzle: Outputs ionized air when the trigger is held down. D. Trigger: Hold down to output ionized air. E. Filter Connection: Hold down the metal tab to attach or release the disposable filter. A B C The compressed gas supply must be clean dry air or nitrogen supplied by a delivery system that utilizes a refrigerated dryer or equivalent water removal to achieve a limit of about 550 ppm water vapor at 35 F (1.66 C) Dew Point. To prevent particles from entering the console, a 2 micron coalescing filter or better is recommended upstream of the gun console. Note that the filter in the console collects small residual particles and aerosols and does not act as a primary filter. The console filter is rated at 0.01 micron for particulates and is effective down to micron for aerosols. An adequate filter that can be recommended for the inlet of the Chargebuster Ion Gun would be a Finite Filter Grade 10 Media Specification. This provides a 95% coalescing efficiency for aerosols with a 0.7 micron (and greater) particle retention. This removes gross amounts of particles, water and/or oil and aerosols. A Grade 6 Media provides 99.98% efficiency when almost total removal of liquid aerosols and particles are required in all pressure ranges down to 0.01 microns. Fine filters need to be changed more often. MOUNTING THE CONSOLE Plug one end of the included 10 cable into the jack on the back of the console. Plug the other end of the cable into the unplugged Wall Transformer. D E F Figure 3: Console features and components CONSOLE A. Power LED: Illuminates when the power is turned ON. B. Power Switch: Turns the power ON or OFF. C. Foot Switch Jack: Connect the optional foot switch here. Contact Service@DescoEMIT.com for more information. Figure 4: Connecting the cable from the Wall Transformer to the back of the console D. Supply Connection: Use with the quick coupling to connect to an air supply. TB-6559 Page 2 of 5

3 Choose a location that will be convenient to the work area and the gas supply. The Console takes up very little space and is adaptable to a variety of permanent or temporary installations. To minimize bends in the gun hose, orient the console so that the open end points toward the work area and the male connector points toward the air supply. I. Use the included screws to attach the supplied mounting plate to the threaded holes on the back of the console. II. Connect the hose and disposable filter to the console. Press the disposable filter release button on the front of the console to lock it down. Push the fitting containing the disposable filter all the way into the opening in the console until it latches with a click. It fits only in the correct orientation. The small plastic fitting on the end of the disposable filter must align with the metal guide coupling in the console. You may have to wiggle the disposable filter slightly while inserting it. Figure 5: Mounting the console to the mounting plate II. Attach the plate to a flat surface, such as a wall or back of a work bench, using suitable screws and fasteners. When mounting to a hollow wall be sure to use #8 screws and 3/4 length anchors as a minimum. MOUNTING TO A GAS SUPPLY When a gas supply is close to the work area and fitted with a standard industrial interchange quick coupling, you may attach the console to the air supply fitting directly. If necessary, use a prefilter as defined in the COMPRESSED GAS REQUIREMENTS section of this technical bulletin. ASSEMBLY NOTE: Protect the hose from sharp objects, abrasion, and high temperatures. Do not pull or pinch the hose while assembling the components. I. Insert the larger diameter end of the air filter into the end of the flexible air hose connector. Press the metal filter release tab at the end of the hose until it locks into place. Figure 7: Connecting the hose and disposable filter to the console III. Attach the included 1/4 NPT female quick connect fitting to your gas supply line. Slide the outer ring on the fitting towards the supply line to insert the mating fitting on the console. You can attach the console directly to the gas supply pipe or attach it using a hose (not supplied). If necessary, use a prefilter as defined in the COMPRESSED GAS REQUIREMENTS section of this technical bulletin. IV. If you would like to use the optional foot switch, plug its cable to the jack located at the top of the console. Operation NOTE: Our recommendation is to set the pressure regulator on your air or nitrogen supply between 20 and 65 psi ( MPa). Discharge times vary depending on air pressure. Pressures of psi ( MPa) are commonly used for decontaminating surfaces. OSHA regulations recommend limiting hand-held air blow-off devices to maximum pressures of 30 psi (0.2 MPa). The hose is rated at 65 psi (0.45 MPa) at temperatures up to 75 F (24 C), and the rating decreases at higher temperatures. When using high pressures, consider the ambient room temperature as well as heat from surrounding equipment. I. Ensure that you are not holding down the trigger, and turn on the power switch located at the top of the console. The power LED should illuminate. Figure 6: Inserting the disposable filter TB-6559 Page 3 of 5

4 II. Hold the gun approximately six inches from the surface you want to neutralize and blow-off. Aim the nozzle and hold down the trigger. The LED on the back of the gun should illuminate. Typically, static charges are discharged within one second. III. Release the trigger when the surface is clean. If the optional foot switch is installed, you may use either the foot switch or gun trigger. REPLACING THE DISPOSABLE FILTER EMIT recommends that the disposable filter be changed every 3 months or when it begins to look dirty. I. Turn power off at the console and disconnect the console from the gas supply. II. Hold down the disposable filter release button on the side of the console. III. Remove the hose and disposable filter from the console by pulling the textured rubber plug where the hose emerges from the console. Rocking the plug back and forth can help loosen the filter. Do not pull the hose itself. IV. Remove the disposable filter from the hose fitting by depressing the metal release tab on the fitting and pulling off the air filter. V. Replace with the new disposable filter by following the procedure in the ASSEMBLY section on page 2. Specifications Ozone Hose < ppm (24 hour accumulation) 65 psi (0.45 MPa) Figure 8: Using the Chargebuster Ion Gun Maintenance All ionization devices will require periodic maintenance for proper operation. Maintenance intervals for ionizers vary widely depending on the type of ionization equipment and use environment. Critical clean room uses will generally require more frequent attention. It is important to set-up a routine schedule for ionizer service. Routine service is typically required to meet quality audit requirements. (ESD Handbook TR section Maintenance / Cleaning) Power Output Gas Input Disposable Filter VAC VAC Hose Length 7 (2.13 m) psi ( MPa) Clean dry air or nitrogen 99.9% efficient 0.01 micron particles micron coalescing Console Dimensions 8.5 x 3.0 x 1.6 (21.6 cm x 7.6 cm x 4.1 cm) CLEANING THE COMPONENTS I. Turn off the console and disconnect it from its electrical power and gas supply sources. II. Using a cloth moistened with the IPA solution, wipe the exterior surfaces of the console and gun to remove any dirt or dust that may have collected. III. Using a swab moistened with the IPA solution, gently clean the emitter points on the gun. Extremely dirty points increase the time needed to discharge static and can affect the ionization balance. TB-6559 Page 4 of 5

5 Limited Warranty EMIT expressly warrants that for a period of one (1) year from the date of purchase EMIT Chargebuster Ion Guns will be free of defects in material (parts) and workmanship (labor). Within the warranty period, a credit for purchase of replacement EMIT Chargebuster Ion Guns, or, at EMIT s option, the Chargebuster Ion Gun will be repaired or replaced free of charge. If product credit is issued, the amount will be calculated by multiplying the unused portion of the expected five year life times the original unit purchase price. Call our Customer Service Department at (Chino, CA) for a Return Material Authorization (RMA) and proper shipping instructions and address. Please include a copy of your original packing slip, invoice, or other proof of date of purchase. Any unit under warranty should be shipped prepaid to the EMIT factory. Warranty replacements will take approximately two weeks. If your unit is out of warranty, call our Customer Service Department at (Chino, CA) for a Return Material Authorization (RMA) and proper shipping instructions and address. EMIT will quote repair charges necessary to bring your unit up to factory standards. Warranty Exclusions THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL OTHER PRODUCT WARRANTIES, EXPRESSED AND IMPLIED, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH ARE SPECIFICALLY DISCLAIMED. The express warranty will not apply to defects or damage due to accidents, neglect, misuse, alterations, operator error, or failure to properly maintain, clean or repair products. Limit of Liability Electronic ionizers use high voltage corona discharge and should not be used in or near flammable or explosive environments. In no event will EMIT or any seller be responsible or liable for any injury, loss or damage, direct or consequential, arising out of the use of or the inability to use the product. Before using, users shall determine the suitability of the product for their intended use, and users assume all risk and liability whatsoever in connection therewith. TB-6559 Page 5 of 5

Chargebuster Ion Gun Installation, Operation and Maintenance

Chargebuster Ion Gun Installation, Operation and Maintenance TECHNICAL BULLETIN TB-6559 Chargebuster Ion Gun Installation, Operation and Maintenance The Chargebuster Ion Gun reduces a static charge of ±1000 V down to ±100 V in less than one second at a distance

More information

Chargebuster Ion Gun Installation, Operation and Maintenance

Chargebuster Ion Gun Installation, Operation and Maintenance TECHNICAL BULLETIN TB-6559 Chargebuster Ion Gun Installation, Operation and Maintenance The Chargebuster Ion Gun reduces a static charge of ±1000 V down to ±100 V in less than one second at a distance

More information

Bench Top Ionizer Installation, Operation and Maintenance

Bench Top Ionizer Installation, Operation and Maintenance TECHNICAL BULLETIN TB-5512 Bench Top Ionizer Installation, Operation and Maintenance Made in America common plastics), and moving personnel who cannot use wrist or heel straps or ESD control flooring and

More information

Chargebuster Overhead Ionizer Installation, Operation and Maintenance

Chargebuster Overhead Ionizer Installation, Operation and Maintenance TECHNICAL BULLETIN TB-6545 Chargebuster Overhead Ionizer Installation, Operation and Maintenance Figure 1. EMIT 50682 Chargebuster Overhead Ionizer Figure 2. EMIT 50681 Chargebuster Overhead Ionizer Made

More information

3 963/963E Benchtop Air Ionizer Instructions

3 963/963E Benchtop Air Ionizer Instructions 3 963/963E Benchtop Air Ionizer Instructions Index Section Page Safety Information...4 1. Description...5 2. Performance...5 3. Power Requirements...5 4. Installation...5 5. Operation...6 6. Maintenance...6

More information

CRITICAL ENVIRONMENT (C/E) SERIES OVERHEAD IONIZER OWNER S MANUAL

CRITICAL ENVIRONMENT (C/E) SERIES OVERHEAD IONIZER OWNER S MANUAL CRITICAL ENVIRONMENT (C/E) SERIES OVERHEAD IONIZER OWNER S MANUAL Made in America DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 (909) 627-8178 Fax (909) 627-7449 DESCO EAST - One Colgate Way, Canton,

More information

Chargebuster Jr. H/O with Emitter Cassette Installation, Operation and Maintenance

Chargebuster Jr. H/O with Emitter Cassette Installation, Operation and Maintenance Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com TECHNICAL BULLETIN TB-2095 Chargebuster Jr. H/O with Emitter Cassette Installation, Operation and Maintenance

More information

Static Eliminators. Overhead Ionizing Blower Model IN5130. Instruction Manual

Static Eliminators. Overhead Ionizing Blower Model IN5130. Instruction Manual Static Eliminators Overhead Ionizing Blower Model IN5130 Instruction Manual 1 Description Contents Model IN5130 1 About Ptec Technology 1 Features 1 Power Requirements 2 2 Operation and Use Environmental

More information

3M Benchtop Air Ionizer 963E. User s Guide

3M Benchtop Air Ionizer 963E. User s Guide 3M Benchtop Air Ionizer 963E User s Guide 1 Table of Contents Section Page Safety Information...3 1. Description...4 2. Performance...4 3. Power Requirements...4 4. Installation...4 5. Operation...5 6.

More information

Thank you for purchasing our Stat Clean No. BBZ-E. Read this instruction manual before use. Keep it in a safe handy place for future reference.

Thank you for purchasing our Stat Clean No. BBZ-E. Read this instruction manual before use. Keep it in a safe handy place for future reference. your solution partner Instruction Manual Thank you for purchasing our Stat Clean No. BBZ-E. Read this instruction manual before use. Keep it in a safe handy place for future reference. Table of Contents

More information

Critical Environment Ionizing Blower. Model 5810i. User s Manual

Critical Environment Ionizing Blower. Model 5810i. User s Manual Critical Environment Ionizing Blower Model 5810i User s Manual About ION Systems ION Systems develops, manufactures, and markets system solutions to manage electrostatic charge. As the world's largest

More information

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138 7428146 Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138 1.0 SAFETY All compressed gases, including air, can be dangerous.

More information

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L BFN 801 Ionizing Blowers Instruction Manual Contents BFN 801 Description

More information

BFN. Static Eliminators. Instruction Manual. BFN 803 Ionizing Blower

BFN. Static Eliminators. Instruction Manual. BFN 803 Ionizing Blower T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L BFN Static Eliminators BFN 803 Ionizing Blower TRANSFORMING TECHNOLOGIES,

More information

Instruction Manual STATIC ERASER TOP FAN. Table of Contents

Instruction Manual STATIC ERASER TOP FAN. Table of Contents STATIC ERASER TOP FAN Instruction Manual Thank you for having purchased Stat Clean No. L-90-E Read this instruction manual carefully before use. Keep it in a safe handy place for future reference. Table

More information

3M Overhead Ionizing Blower 991A

3M Overhead Ionizing Blower 991A 3M Overhead Ionizing Blower 991A User s Manual January 2014 78-9101-8683-8 Important Safety Information Carefully read the following safety information before installing or operating the equipment. Failure

More information

CHARGED PLATE DETECTORS

CHARGED PLATE DETECTORS CHARGED PLATE DETECTORS Model 205C and 205C-x10 Instruction Manual 4-09 1.0 GENERAL The Model 205C and 205C-x10 Charged Plate Detectors are used in conjunction with the ETS Model 212 Static Meter. They

More information

BFN. Static Eliminators. Instruction Manual. BFN 802 Ionizing Blower

BFN. Static Eliminators. Instruction Manual. BFN 802 Ionizing Blower T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L BFN Static Eliminators BFN 802 Ionizing Blower Instruction Manual Contents

More information

Condensate Pump. Installation and Safety Instructions CP-16 CP

Condensate Pump. Installation and Safety Instructions CP-16 CP Condensate Pump Installation and Safety Instructions CP-16 CP-16-230 CP-16 CP-16-230 Rated Voltage 120 Volts / 60 Hz 220 Volts / 60 Hz (208-230) Rated Current Draw 1.9 Amps 1.0 Amps Input Type USA 3-prong

More information

14 Upright Vacuum with HEPA Filter & Dual Power

14 Upright Vacuum with HEPA Filter & Dual Power E29990-00 14 Upright Vacuum with HEPA Filter & Dual Power Operator and Parts Manual 1001 Brown Avenue Toledo, Ohio 43607-0127 Customer Service: 888-GO-BETCO Fax: 800-445-5056 Technical Service: 877-856-5954

More information

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314) DRY AIR SYSTEMS, INC. 2655 Metro Boulevard Maryland Heights, Missouri 63043 (314) 344-1114 fax (314) 344-0677 HD SERIES DRIERS TABLE OF CONTENTS WHY AN AIR DRYER 3 WHAT IS A DESICCANT AIR DRYER 3 Desiccant

More information

AirInstinct Air Purifier

AirInstinct Air Purifier User s Guide Model: AIR75B AirInstinct Air Purifier TM Important! Read this manual carefully, and keep for future reference. Enjoy Congratulations on your purchase of the Oreck AirInstinct TM Air Purifier.

More information

MST MODEL S1 AIRLINE "CO" MONITORING AND LOW PRESSURE WARNING SYSTEM MANUAL

MST MODEL S1 AIRLINE CO MONITORING AND LOW PRESSURE WARNING SYSTEM MANUAL MST MODEL 5700 - S1 AIRLINE "CO" MONITORING AND LOW PRESSURE WARNING SYSTEM MANUAL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed

More information

Quick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

Quick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Document No. 1800-60 Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831

More information

READ AND SAVE THESE INSTRUCTIONS. Air Boss Model T5200 Custom Packaged Electronic Air Cleaner. TRION

READ AND SAVE THESE INSTRUCTIONS. Air Boss Model T5200 Custom Packaged Electronic Air Cleaner. TRION READ AND SAVE THESE INSTRUCTIONS Air Boss Model T5200 Custom Packaged Electronic Air Cleaner TRION Installation, Operation, & Service Manual Electrostatic Precipitators for Commercial & Industrial Applications

More information

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6 OWNERS MANUAL BOSS COMPRESSED AIR DRYER Distributed by Air & Vacuum Process, Inc. Phone: 281-866-9700 Fax: 281-866-9717 Email: sales@airvacuumprocess.com SAFETY... Page 2 MAINTENANCE... Page 5 INSTALLATION...

More information

PARTS OVERVIEW GO TO VAPAMORE.COM TO SEE THE MR-75 AMICO INSTRUCTIONAL VIDEO

PARTS OVERVIEW GO TO VAPAMORE.COM TO SEE THE MR-75 AMICO INSTRUCTIONAL VIDEO SAFETY INFORMATION FAILURE TO FOLLOW SAFETY INFORMATION AND WARNINGS MAY CAUSE PERMANENT DAMAGE AND VOID PRODUCT WARRANTY. PARTS OVERVIEW around water. use only with a grounded outlet. Vapamore in order

More information

Operating Instructions Model 4400/VC-115V Portable Powder Filler (115VAC. Model)

Operating Instructions Model 4400/VC-115V Portable Powder Filler (115VAC. Model) Operating Instructions Model 4400/VC-115V Portable Powder Filler (115VAC. Model) First Release... 6/18/96 Rev. C... 1/16/98 Rev. D... 5/01/00 Operating Instructions, Model 4400/VC (Rev. D, 5/01/2000)...

More information

3 Scotch Mini-Weld Adhesive System User s Manual

3 Scotch Mini-Weld Adhesive System User s Manual 3 Scotch Mini-Weld Adhesive System User s Manual The Scotch Mini-Weld Adhesive System Includes The items shown below: Contents of User s Manual Ordering Replacement Parts... 1 Important Safety Information...

More information

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL GASGUARD LEL 3 Ammonia Sensor OPERATING & INSTALLATION MANUAL GasGuard LEL 3 Operating and Installation Manual 2 Table of Contents 3GasGuard LEL Operating and Instruction Manual General description. 4

More information

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50 3227447 Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50 GENERAL SAFETY INFORMATION 1. PRESSURIZED DEVICES: This equipment is a pressure containing device.

More information

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL 2 Table of Contents GasGuard H 2-1% General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6 Operation..

More information

D-TEK Select. Refrigerant Leak Detector

D-TEK Select. Refrigerant Leak Detector O P E R A T I N G M A N U A L D-TEK Select Refrigerant Leak Detector DECLARATION OF CONFORMITY This is to certify that this equipment, designed and manufactured by INFICON Inc., Two Technology Place, East

More information

Guardian CR2000 Overhead Ionizing Air Blower. User s Manual

Guardian CR2000 Overhead Ionizing Air Blower. User s Manual Guardian CR2000 Overhead Ionizing Air Blower User s Manual Tabel of Contents SECTION 1: Description SECTION 2: Safety SECTION 3: Features SECTION 4: Specifications SECTION 5: Installation SECTION 6: Operation

More information

SAFETY INFORMATION GO TO VAPAMORE.COM TO SEE THE MR-75 AMICO INSTRUCTIONAL VIDEO

SAFETY INFORMATION GO TO VAPAMORE.COM TO SEE THE MR-75 AMICO INSTRUCTIONAL VIDEO SAFETY INFORMATION FAILURE TO FOLLOW SAFETY INFORMATION AND WARNINGS MAY CAUSE PERMANENT DAMAGE AND VOID PRODUCT WARRANTY. around water. use only with a grounded outlet. Only use distiled water. Using

More information

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR Model 91797 ASSEMBLY and Operating Instructions Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure

More information

INGERSOLLrAND AIR COMPRESSORS CAUTION: HMD SERIES AIR DRYERS MODELS 18 THROUGH 385 OPERATORS/ INSTRUCTION MANUAL REPLACEMENT PARTS

INGERSOLLrAND AIR COMPRESSORS CAUTION: HMD SERIES AIR DRYERS MODELS 18 THROUGH 385 OPERATORS/ INSTRUCTION MANUAL REPLACEMENT PARTS INGERSOLLrAND AIR COMPRESSORS HMD SERIES AIR DRYERS MODELS 18 THROUGH 385 OPERATORS/ INSTRUCTION MANUAL REPLACEMENT PARTS CAUTION: For HMD Models 84 Through 385 ONLY 1. Remove Dryer Chambers And Protective

More information

DBF 4XL Dryer Booster Fans

DBF 4XL Dryer Booster Fans Installation and Operation Manual Item #: 401315 Rev Date: 050814 DBF 4XL Dryer Booster Fans DBF4XL Kit Includes: Dryer Booster Fan, 1 pc Fan Mounting Bracket and Hardware, 1 pc Wall Label (Mount on wasll

More information

Owner s. 18 Misting MF18W. To view

Owner s. 18 Misting MF18W. To view Owner s Manual MF18W 18 Misting Fan IMPORTANT SAFETY INFORMATION: Please carefully read this manual before attempting to install or use this misting fan. For your safety, comply with all safety instructionss

More information

Desiccant Air Drying System

Desiccant Air Drying System Instructions - Parts List Desiccant Air Drying System 3099D Model 30 Maximum Operating Pressure 0 psi (. MPa, bar) Maximum Temperature 50 F (5 C) Includes: Part No. Description 30 Stage - Air Filter with

More information

Ultrasonic Humidification System Model 5462 & Model 5472 OPERATING MANUAL

Ultrasonic Humidification System Model 5462 & Model 5472 OPERATING MANUAL Ultrasonic Humidification System Model 5462 & Model 5472 OPERATING MANUAL 6/30/06 www.electrotechsystems.com TABLE OF CONTENTS 1.0 General Page 01 2.0 Description 01 3.0 Set-Up 01 4.0 Model 5462 03 4.2

More information

IONIZING AIR BLOWER INSTRUCTION MANUAL

IONIZING AIR BLOWER INSTRUCTION MANUAL IONIZING XC AIR BLOWER INSTRUCTION MANUAL Thank you for purchasing this XC Ionizing Air Blower. It is designed to eliminate the static electricity from a charged object. Please read this manual before

More information

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532 Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

Installation and Operating Guide Document No Vacuum Chambers Copyright 2017 Terra Universal Inc. All rights reserved.

Installation and Operating Guide Document No Vacuum Chambers Copyright 2017 Terra Universal Inc. All rights reserved. Document No. 1800-60 Copyright 2017 Terra Universal Inc. All rights reserved. Revised June 2017 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX:

More information

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 700

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 700 INSTALLATION and INSTRUCTION MANUAL for QUALITY AIR BREATHING SYSTEMS Model ABM - 700 M A R T E C H S E R V I C E S C O M P A N Y P.O. Box 7079 OFFICE: 800-831-1525 Mazeppa, MN 55956 Fax : (507)843-4953

More information

SSS BPV- 40 Backpack Vacuum

SSS BPV- 40 Backpack Vacuum SSS BPV- 40 Backpack Vacuum Manual The contents of this manual are based on the latest product information available at the time of publication. Triple S reserves the right to make changes or improvements

More information

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions

More information

Because you re not like everyone else. MISTING FAN MF18W OWNER S MANUAL

Because you re not like everyone else. MISTING FAN MF18W OWNER S MANUAL Because you re not like everyone else. MISTING FAN MF18W OWNER S MANUAL 2 BECAUSE YOU RE NOT LIKE EVERYONE ELSE. And neither are we. Always at the forefront of our industry, our goal is to offer the best

More information

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL 2 Table of Contents GasGuard NH 3 2% General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6

More information

Industrial Vacuums, Inc

Industrial Vacuums, Inc Instructions/Spare Parts Manual Nilfisk Model GWD255 Drum Top Vacuum CAUTION: This Nilfisk vacuum cleaner is not to be used in explosion-hazardous areas, as serious injury could result. Under no circumstances

More information

Superdryer Dehumidifiers

Superdryer Dehumidifiers Superdryer Dehumidifiers Installation and Operations Manual Read and Save These Instructions Distributed Exclusively By: Air Cleaning Equipment, Inc. Broadway, NC 27505 Phone: 919-258-3330 www.aircleaningequipment.com

More information

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

Owner s Manual Refrigerated Compressed Air Dryers Model F-100 Owner s Manual Refrigerated Compressed Air Dryers Model F-100 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61340-4-7 Edition 1.0 2010-01 Electrostatics Part 4-7: Standard test methods for specific applications Ionization INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE U ICS 17.200.99;

More information

H-10PM. Refrigerant Leak Detector

H-10PM. Refrigerant Leak Detector H-10PM Refrigerant Leak Detector Congratulations! You have just purchased the most versatile, high performance service leak detector available in the industry today. It will detect refrigerants with a

More information

MaxLite LED Round Pendant Highbay Series

MaxLite LED Round Pendant Highbay Series General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions

More information

Eco-Steamer SSC-0312 INSTRUCTION MANUAL CONTENTS

Eco-Steamer SSC-0312 INSTRUCTION MANUAL CONTENTS INSTRUCTION MANUAL Eco-Steamer SSC-0312 CONTENTS Important Safeguards...1 Description of Eco-Steamer...2 Main Features of Eco-Steamer...2 Instructions for Use...3 How to Assemble and Use...3 Accessories...3

More information

Cat 5 Pro Vacuum OPERATOR S MANUAL

Cat 5 Pro Vacuum OPERATOR S MANUAL Cat 5 Pro Vacuum OPERATOR S MANUAL Concrete Polishing Solutions PO Box 520 * Norris, TN 37828 Phone: (865) 494-8200 * Fax: (865) 494-8300 Toll Free: (877) 472-8200 * www.go2cps.com Table Of Contents General

More information

CONTENTS 1. 1 Ionizing Air Guns Overview Benefits Applications Models Ionizing Air Guns... 3

CONTENTS 1. 1 Ionizing Air Guns Overview Benefits Applications Models Ionizing Air Guns... 3 CONTENTS 1 Ionizing Air Guns Contents 1 Ionizing Air Guns 2 1.1 Overview........................................ 2 1.2 Benefits........................................ 2 1.3 Applications......................................

More information

4 Table Of Contents Safety instructions... 6 Unpacking instructions... 7 Machine overview... 8 Connecting the hose... 9 Telescoping extension... 10 Starting the brush... 11 Checking the brush... 12 Filter

More information

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL GASGUARD NH 3 Ammonia Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual 2 Table of Contents GasGuard NH 3 Operating and Instruction Manual General description. 4 Installation.. 4

More information

Reacti-Therm I and III Heating Modules

Reacti-Therm I and III Heating Modules INSTRUCTIONS Reacti-Therm I and III Heating Modules TS-18822 TS-18824 Number TS-18822 TS-18824 Description Reacti-Therm I Heating Module (single block) Reacti-Therm III Heating Module (triple block) 2101.1

More information

Desiccant Air Drying System

Desiccant Air Drying System Instructions - Parts List Desiccant Air Drying System 30992L EN Model 23440 Maximum Operating Pressure 60 psi (. MPa, bar) Maximum Temperature 50 F (65 C) Model 24M78 Maximum Operating Pressure 75 psi

More information

OPERATION INSTRUCTION

OPERATION INSTRUCTION IONIZING AIR BLOWER PC OPERATION INSTRUCTION Thank you for purchasing this PC Ionizing Air Blower. It is designed to eliminate the static electricity from a charged object. Please read this manual before

More information

MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H056

MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H056 MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL Call 888.896.8786 Model #: H056 IMPORTANT SAFE T SAVE THESE INSTRUCTIONS When using an electrical appliance, basic safety precautions should always be observed,

More information

UV PRO 15, ozone generator instruction manual ****IMPORTANT****

UV PRO 15, ozone generator instruction manual ****IMPORTANT**** UV PRO 15,000 6800 4000 2800 ozone generator instruction manual ****IMPORTANT**** PLEASE RETAIN THE SHIPPING BOX AND PACKING FOR FUTURE USE! If the product needs to be returned for any reason there may

More information

User s Manual and Operating Instructions

User s Manual and Operating Instructions User s Manual and Operating Instructions Model Numbers: CL-30P-DDF, CL-20F-DDF, CL-24O-DDF, CL-30-DDF READ AND SAVE THESE INSTRUCTIONS IMPORTANT: Read and understand all of the directions in this manual

More information

Drain Tempering Reservoir READ & SAVE THESE INSTRUCTIONS. Installation, Operation, & Maintenance. TRION

Drain Tempering Reservoir READ & SAVE THESE INSTRUCTIONS. Installation, Operation, & Maintenance. TRION READ & SAVE THESE INSTRUCTIONS Installation, Operation, & Maintenance TRION www.trioniaq.com Installation, Operation, & Maintenance Manual TABLE OF CONTENTS Warranty...3 Introduction...4 Operational Characteristics...4

More information

ZD-985 Desoldering Station

ZD-985 Desoldering Station ZD-985 Desoldering Station 2 Contents Contents... 3 Unpacking and Setting Up Your ZD-985 Desoldering Station... 4 Setting Up the Unit... 5 Auto Tip Saver Function... 8 Tips and Techniques... 8 Alloy Melt

More information

OZX-300ST Ozone Generator

OZX-300ST Ozone Generator OZX-300ST Ozone Generator Shanghai ENALY M&E Ltd. Thank You for Purchasing Our Products With proper care and maintenance, this device should give you years of trouble-free service. Please take the time

More information

7 1/4" 3 3/8" Pump Max. Max. Line Weight Model No. HP Housing Inlet/Outlet Fluid Temp. Pressure (Lbs.)

7 1/4 3 3/8 Pump Max. Max. Line Weight Model No. HP Housing Inlet/Outlet Fluid Temp. Pressure (Lbs.) Installation & Operating Manual Please read this manual carefully before attempting to install, operate or maintain the product described. Failure to comply with the information provided in this manual

More information

OWNER S MANUAL. Models SCU-H11, SCU-H9, SCU-H7, SCU-H5, SCU-H3

OWNER S MANUAL. Models SCU-H11, SCU-H9, SCU-H7, SCU-H5, SCU-H3 Warranty Information Maintenance Troubleshooting Operating Instructions Installation OWNER S MANUAL Models SCU-H11, SCU-H9, SCU-H7, SCU-H5, SCU-H3 DOMESTIC USE ONLY Please read this document carefully

More information

WHEATGRASS JUICER C O M M E R C I A L. INSTRUCTION MANUAL Model No

WHEATGRASS JUICER C O M M E R C I A L. INSTRUCTION MANUAL Model No COMMERCIAL PRODUCTS ATTENTION If any components of this unit are broken, do not operate properly, or for product returns, please contact Pragotrade at 1-800-814-4895 Outside the U.S. call 440-638-3131.

More information

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System 1 Revised 11/18/10 2320 Lakecrest Drive, Pekin IL 61554 PH. (888) 747-4389 Fax (309) 495-0625 Website: www.getzequipment.com LIMITED

More information

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual GG-NH3-2% AMMONIA GAS SENSOR Installation and Operation Manual 2 GG-NH3-2% Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration

More information

DEDPV-705, DEDPV-705 Hi Alt Dryer Exhaust Duct Power Ventilator (DEDPV)

DEDPV-705, DEDPV-705 Hi Alt Dryer Exhaust Duct Power Ventilator (DEDPV) Installation and Operation Manual Item #: 483443 Rev Date: 2018-04-23 DEDPV-705, DEDPV-705 Hi Alt Dryer Exhaust Duct Power Ventilator (DEDPV) DEDPV-705 Kit Includes: Inline Fan with Integral Control, 1

More information

RAM 50 Series Operation Manual

RAM 50 Series Operation Manual RAM 50 Series Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS Page Introduction... 3 Principles of operation... 3 Overview... 4 Description... 4 Installation... 7

More information

Air Pump Up to 800 gallons

Air Pump Up to 800 gallons Air Pump Up to 800 gallons REMINDER CALL 1-888-755-6750 BEFORE RETURNING TO STORE. PACKAGE CONTENTS ITEM #PBPAPK40W Questions, problems, missing parts? Before returning to your retailer, call our customer

More information

FiberPRO. 15 Series. High Pressure Carpet Extractors. Operator and Parts Manual E E E

FiberPRO. 15 Series. High Pressure Carpet Extractors. Operator and Parts Manual E E E E29977-00 E29979-00 E29978-00 FiberPRO 15 Series High Pressure Carpet Extractors Operator and Parts Manual 1001 Brown Avenue Toledo, Ohio 43607-0127 Customer Service: 888-GO-BETCO Fax: 800-445-5056 Technical

More information

RAM 50 Series Operation Manual

RAM 50 Series Operation Manual RAM 50 Series Operation Manual Worldwide Manufacturer of Gas Detection Solutions Table of Contents Page Introduction... 3 Detection Principle... 3 Overview... 3 Description... 4 Switches... 4 Indicators...

More information

Air Dryers & After Coolers Dry Land

Air Dryers & After Coolers Dry Land Air Dryers & After Coolers Dry Land See limited warranty documentation for complete details Air Dryers Features Pirate Brand Dry Land air dryers are the perfect solution for the mobile blasting and painting

More information

ELECTRONIC AIR CLEANERS

ELECTRONIC AIR CLEANERS owner s manual OWNER S MANUAL Includes Safety, Operating and Maintenance Instructions MODEL 5000 ELECTRONIC AIR CLEANERS Nobody Makes Clean Air Easier read & save these instructions WARNING: 120 Volts

More information

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL GASGUARD O 2 Oxygen Sensor OPERATING & INSTALLATION MANUAL 2 Table of Contents General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6 Operation.. 7 Start-up...

More information

USER MANUAL. Bottled Water Dispenser SAVE FOR FUTURE USE. Model #

USER MANUAL. Bottled Water Dispenser SAVE FOR FUTURE USE. Model # Model # 900161: Page 1 USER MANUAL Bottled Water Dispenser Model # 900161 TO REDUCE THE RISK OF INJURY AND PROPERTY DAMAGE, USER MUST READ THIS MANUAL BEFORE ASSEMBLING, INSTALLING & OPERATING DISPENSER.

More information

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL This manual is provided as a guide to installation. All installations must comply with any and all local and national electrical

More information

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG) WET/DRY VACUUM Operating Instructions (ENG) MODEL: T1 y QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO 9001. Read these instructions before operating the machine.

More information

Parts and Instruction Manual ET Extraction Tool

Parts and Instruction Manual ET Extraction Tool Parts and Instruction Manual ET Extraction Tool This manual is furnished with each new MINUTEMAN ET Extraction Tool. This provides the necessary operating and preventive maintenance instructions. Operators

More information

IMPORTANT SAFEGUARDS

IMPORTANT SAFEGUARDS IMPORTANT SAFEGUARDS Definitions Whenever used, the following symbol and terms identify safety and property damage messages and designate a level of hazard seriousness. - This is the safety alert symbol.

More information

SKORPION Process Air Heater

SKORPION Process Air Heater OPERATING INSTRUCTIONS 2/6/2018 SKORPION Process Air Heater Safety SHOCK HAZARD! Only qualified individuals should install this heater and related controls. Follow all applicable electrical codes and use

More information

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS Enspeco AUTOMOTIVE REFRIGERANT MANAGEMENT SYSTEMS RMS 5000 INSTRUCTIONS The Enspeco Refrigerant Management System 5000 provides fast and efficient recovery, recycling and charging of automotive air conditioning

More information

PACKAGED ELECTRONIC AIR CLEANER. Air Boss T-Series. Model T5200 INSTALLATION OPERATION SERVICE. Electrostatic Precipitator for Industrial Applications

PACKAGED ELECTRONIC AIR CLEANER. Air Boss T-Series. Model T5200 INSTALLATION OPERATION SERVICE. Electrostatic Precipitator for Industrial Applications PACKAGED ELECTRONIC AIR CLEANER Air Boss T-Series Model T5200 INSTALLATION OPERATION SERVICE Electrostatic Precipitator for Industrial Applications 101 McNeill Road Sanford, NC 27330 (919) 775-2201 Fax:

More information

SM-909/SM /2" Sweat 3/4" Sweat 3 3/8" F.L. Max. Max. Line Weight Model No. HP Inlet/Outlet Volts Amps Fluid Temp. Pressure (Lbs.

SM-909/SM /2 Sweat 3/4 Sweat 3 3/8 F.L. Max. Max. Line Weight Model No. HP Inlet/Outlet Volts Amps Fluid Temp. Pressure (Lbs. Installation & Operating Manual Please read this manual carefully before attempting to install, operate or maintain the product described. Failure to comply with the information provided in this manual

More information

Item # Modular Blast CaBinEt instructions

Item # Modular Blast CaBinEt instructions Item #20464 Modular Blast CaBinEt instructions The Eastwood Modular Blast Cabinet is specifically designed with heavy-duty components and a quality powdercoated finish to provide years of trouble free

More information

STATIC ELIMINATOR I443A INSTRUCTION MANUAL

STATIC ELIMINATOR I443A INSTRUCTION MANUAL STATIC ELIMINATOR I443A INSTRUCTION MANUAL Thank you for purchasing a Static Eliminator. It is designed to eliminate the static charge from a charged object. Please read this manual before operating the

More information

Plastic Housing Plastic Housing Stainless Housing SM /8" 3 3/8"

Plastic Housing Plastic Housing Stainless Housing SM /8 3 3/8 Installation & Operating Manual Please read this manual carefully before attempting to install, operate or maintain the product described. Failure to comply with the information provided in this manual

More information

DRYAIRE MEMBRANE AIR DRYING SYSTEM MODEL 6770

DRYAIRE MEMBRANE AIR DRYING SYSTEM MODEL 6770 DRYAIRE MEMBRANE AIR DRYING SYSTEM MODEL 6770 System Includes: Air Filter w/overnight Drain (Part No. 22601) Coalescer w/overnight Drain (Part No. 22605) Air Regulator Assembly (Part No. 1640) Membrane

More information

THANK YOU FOR PURCHASING THE LV-H133 TOWER HEPA AIR PURIFIER BY LEVOIT! GET STYLE #LevoitLove #LevoitLifestyle

THANK YOU FOR PURCHASING THE LV-H133 TOWER HEPA AIR PURIFIER BY LEVOIT! GET STYLE #LevoitLove #LevoitLifestyle Model No.: LV-H133 Tower HEPA Air Purifier Questions or Concerns? Please contact us Monday - Friday 9:00 am - 5:00 pm PT at support@levoit.com or (888) 726-8520. THANK YOU FOR PURCHASING THE LV-H133 TOWER

More information

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715 INSTALLATION and INSTRUCTION MANUAL for QUALITY AIR BREATHING SYSTEMS Model ABM - 715 M A R T E C H S E R V I C E S C O M P A N Y P.O. Box 7079 OFFICE: 800-831-1525 Mazeppa, MN 55956 Fax : (507)843-4953

More information

Nilfisk Model VHS255 Drum Top Vacuum

Nilfisk Model VHS255 Drum Top Vacuum Instructions/Spare Parts Manual Nilfisk Model VHS255 Drum Top Vacuum CAUTION: This Nilfisk vacuum cleaner is not to be used in classified (hazardous) environments, as serious injury could result. Under

More information

Cool Flow & CoolOR PERSONAL COOLING SYSTEMS POLAR PRODUCTS polarproducts.com

Cool Flow & CoolOR PERSONAL COOLING SYSTEMS POLAR PRODUCTS polarproducts.com I N S T R U C T I O N S Cool Flow & CoolOR PERSONAL COOLING SYSTEMS POLAR PRODUCTS 800-763-8423 polarproducts.com Cool Flow & CoolOR PERSONAL COOLING SYSTEMS Instructions for Patients and Medical Professionals

More information

Air Purifier. User s Guide. Important! Oreck Air Purifier with HEPA Filtration. Read this manual carefully, and keep for future reference.

Air Purifier. User s Guide. Important! Oreck Air Purifier with HEPA Filtration. Read this manual carefully, and keep for future reference. User s Guide Air Purifier Important! Read this manual carefully, and keep for future reference. Oreck Air Purifier with HEPA Filtration Enjoy Congratulations on your purchase of the Oreck Air Purifier

More information