MPE 4-76 kw. Outdoor monobloc unit. Air chillers and heat pumps MPE PLUS. Efficiency under all operating conditions. 152 galletti.
|
|
- Opal Pierce
- 5 years ago
- Views:
Transcription
1 Air chillers and heat pumps MPE Outdoor monobloc unit MPE - kw Efficiency under all operating conditions Rotary compressor PLUS Scroll compressor R-0A R-0A refrigerant Cooling only Cooling / Heating Monobloc unit Completely configurable range Dual-compressor version that guarantees high efficiency at partial loads Production of chilled water up to an air temperature of C Built-in hydronic unit Access to the tax incentives provided for energy retrofitting Axial fans MPE water chillers and heat pumps are designed for outdoor installation in both residential and industrial applications. The range uses R0A refrigerant, which assures high levels of performance with relatively low energy consumption and features models in the chiller and heat pump version, with cooling capacities ranging from to kw and heating capacities from to kw. The finned block heat exchangers have been optimised for R0A and use mm copper pipes, which permit a better heat exchange and quiet operation of the fans. Their generous sizing guarantees the production of chilled water even with outdoor air temperatures as high as C. In the MPET models, with a double compressor on the same cooling circuit, the working temperature range is extended further and efficiency at partial loads increases. In demanding working conditions the microprocessor controller activates the capacity control mode, doubling the condensing surface available to the single compressor. The self-adaptive logic allows the setpoint to be adjusted automatically according to the outdoor temperature in order to reduce consumption and broaden the working temperature range. The unit can also function in systems with a low water content, even without the use of a water buffer tank, thanks to the automatic adjustment which limits the number of compressor starts and thus extends the life of the compressors themselves. The exclusive Smart Defrost System (optional feature available with the advanced controller) can correctly identify an impairment of performance in the outdoor exchanger due to the formation of ice and minimise the process time in relation to normal operation of the unit. MPE heat pumps and water chillers are designed for heating or cooling the water to be used in air-conditioning systems for residential or commercial use. VM000-C
2 MPE - kw MAIN COMPONENTS Structure Painted galvanised sheet steel structure (RAL900) for an attractive look and effective resistance to corrosive agents. Fastening devices are made of non-oxidizable carbon steel that has undergone surface-passivating treatments. Customised hydraulic kit The structure can accommodate hydronic kits with pump, expansion tank, and buffer tank. High head pump made entirely of stainless steel, already configured for use with mixtures of water and ethylene glycol up to % and provided with internal thermal protection. Fan drive assembly Electric fan with external rotor motor directly keyed to the axial fan, with internal thermal protection on the windings. Finned block heat exchanger Made of mm diameter copper pipes and aluminium fins. The heat exchangers particular design makes it possible to speed up to the maximum the defrost phases in the versions with heat pump with obvious benefits to seasonal efficiency while operating in heating mode. Electronic microprocessor controller The electronic controller enables the complete control of the MPE unit. It can be easily accessed through a polycarbonate flap with IP protection rating. It implements the compressor regulation logic and allows the complete management of the unit s other parts, the reversal of the cooling cycle, and the alarms. CONFIGURATION The models are completely configurable by selecting the version and the options. To the right is shown an example of configuration. AVAILABLE VERSIONS Cooling only versions MPE..C0AA Unit with 00V - N - 0 Hz power supply MPE..CMAA Unit with 0V Hz power supply MPE..CAA Unit with circuit breakers and 00V - N - 0 Hz power supply MPE..CAA Unit with circuit breakers and 0V Hz power supply Version Optional 9 0 MPE00C0AA A S 0 E 0 M 0 G To verify the compatibility of the options, use the selection software or the price list. Versions with reversible heat pump MPE H0AA Unit with 00V - N - 0 Hz power supply MPE HMAA Unit with 0V Hz power supply MPE...HAA Unit with circuit breakers and 00V - N - 0 Hz power supply MPE...HAA Unit with circuit breakers and 0V Hz power supply CONFIGURATION OPTIONS - EXPANSION VALVE 0 Traditional A Electronic 0V B FLOOR PACK * - PUMP AND ACCESSORIES Pump + expansion tank + filling tap Dual pump + expansion tank + filling tap - INERTIAL BUFFER TANK S Present - PARTIAL HEAT RECOVERY D Desuperheater with pump contact - AIR FLOW MODULATION C Condensation control with fans adjusted by potentiometer E Condensation control, EC brushless electronically controlled fans - ANTIFREEZE KIT E For units with evaporator only P For units with evaporator, pump and expansion tank S For units with evaporator, pump, expansion tank and tank - SOUND INSULATION Compressor compartment soundproofing Compressor silencing housings Opt + Opt - COOLING ACCESSORIES 0 None M Refrigerant pressure gauges 9 - REMOTE CONTROL Output RS (Modbus or Carel protocol) S Simplified remote control M BASE microprocessor remote control (Modbus disabling) X ADVANCED microprocessor remote control L LON FTT0 serial card 0 -SPECIAL HEAT EXCHANGERS 0 Standard R Copper / copper C Cataphoresis B Fins pre-coated with epoxy paint - HEAT EXCHANGER PROTECTIVE GRILLE G Present - COMPRESSOR OPTIONS Power factor correction capacitors Soft starter Power factor correction capacitors + soft starter Low air/water temperature (crankcase heating element) - CONTROL MICROPROCESSOR BASE control microprocessor ADVANCED control microprocessor ADVANCED control microprocessor + GSM kit ADVANCED control microprocessor + clock card Air chillers and heat pumps - MPE * Includes electronic valve and condensation control ACCESSORIES - Base rubber vibration dumpers - Kit of spring vibration dampers - Inertial tank module for under-base installation - Tank module connection kit - Simplified remote control - MYCHILLER BASE (RS is a mandatory accessory) - MYCHILLER PLUS (RS is a mandatory accessory) VM000-C
3 Air chillers and heat pumps MPE Rated technical data MPE-C M M M M 0 Power supply V-ph-Hz N-0 00-N-0 Cooling capacity () (E) kw,0,09,,0, 9, Power input () (E) kw,,,,,, EER () (E),0,9,9,,, ESEER (E),,9,,9,, Eurovent efficiency class B B B E C C Water flow () l/h Water pressure drop () (E) kpa < < Available pressure head - standard pump () kpa 0 Maximum current absorption A 9 9 Startup current A Startup current with softstarter kit A 0 No. of compressors / circuits / / / / / / Expansion vessel dm Buffer tank volume dm Sound power level () (E) db(a) 9 Transport weight unit with pump and tank kg Operating weight unit with pump and full tank kg MPE-C 0M Power supply V-ph-Hz N-0 00-N-0 00-N-0 00-N-0 00-N-0 Cooling capacity () (E) kw 9,,,,0 9,, Power input () (E) kw,,,9,,, EER () (E),,9,,,, ESEER (E),,9,,0,, Eurovent efficiency class C B C D D C Water flow () l/h Water pressure drop () (E) kpa 9 Available pressure head - standard pump () kpa 0 0 Maximum current absorption A Startup current A Startup current with softstarter kit A 0 No. of compressors / circuits / / / / / / Expansion vessel dm Buffer tank volume dm Sound power level () (E) db(a) Transport weight unit with pump and tank kg 9 9 Operating weight unit with pump and full tank kg 0 () Water temperature / C, outdoor air temperature C (UNI EN :0) () Sound power level measured according to UNI EN ISO 9 (E) EUROVENT certified data VM000-C
4 MPE - kw Rated technical data MPE-C Power supply V-ph-Hz 00-N-0 00-N-0 00-N-0 00-N-0 00-N-0 00-N-0 00-N-0 Cooling capacity () (E) kw,,9,, 9,,0, Power input () (E) kw 9,, 0,,,0,, EER () (E),,,0,9,0,, ESEER (E),,,,,,0,0 Eurovent efficiency class C A B B B C D Water flow () l/h 00 9 Water pressure drop () (E) kpa Available pressure head - standard pump () kpa 0 9 Maximum current absorption A Startup current A Startup current with softstarter kit A No. of compressors / circuits / / / / / / / Expansion vessel dm Buffer tank volume dm 0 Sound power level () (E) db(a) Transport weight unit with pump and tank kg Operating weight unit with pump and full tank kg MPE-C T0 T T0 T T T T9 T Power supply V-ph-Hz 00-N-0 00-N-0 00-N-0 00-N-0 00-N-0 00-N-0 00-N-0 00-N-0 Cooling capacity () (E) kw 9,,9 9,,,, 9,, Power input () (E) kw 0,,,9,,,,,0 EER () (E),,,,,90,,,0 ESEER (E),,,,0,0,0,, Eurovent efficiency class C D C D B C C C Water flow () l/h Water pressure drop () (E) kpa 0 0 Available pressure head - standard pump () kpa 9 9 Maximum current absorption A 9 Startup current A Startup current with softstarter kit A No. of compressors / circuits / / / / / / / / Expansion vessel dm Buffer tank volume dm Sound power level () (E) db(a) Transport weight unit with pump and tank kg Operating weight unit with pump and full tank kg Air chillers and heat pumps - MPE () Water temperature / C, outdoor air temperature C (UNI EN :0) () Sound power level measured according to UNI EN ISO 9 (E) EUROVENT certified data VM000-C
5 Air chillers and heat pumps MPE Rated technical data MPE-H 00 M 00 M 00 M 00 M M Power supply V-ph-Hz N Cooling capacity () (E) kw,0,99,,,,9 Power input () (E) kw,,,,,, EER () (E),9,9,,,, ESEER (E),,,,9,9, Eurovent efficiency class B B C E D C Water flow () l/h Water pressure drop () (E) kpa < < Available pressure head - standard pump () kpa 0 Heating capacity () (E) kw,,,9 0, 9,9,0 Power input () (E) kw,,,,,, COP () (E),,,9,,0,9 Eurovent efficiency class A A B C B C Water flow () l/h Water pressure drop () (E) kpa < < Available pressure head - standard pump () kpa 0 Maximum current absorption A 9 9 Startup current A Startup current with softstarter kit A 0 No. of compressors / circuits / / / / / / Expansion vessel dm Buffer tank volume dm Sound power level () (E) db(a) 9 Transport weight unit with pump and tank kg 0 0 Operating weight unit with pump and full tank kg MPE-H Power supply V-ph-Hz 00-N-0 00-N-0 00-N-0 00-N-0 00-N-0 00-N-0 Cooling capacity () (E) kw,99,,, 9,, Power input () (E) kw,,,,,0, EER () (E),,90,,,, ESEER (E),,,,,, Eurovent efficiency class C B C D D C Water flow () l/h Water pressure drop () (E) kpa Available pressure head - standard pump () kpa 0 0 Heating capacity () (E) kw,0,, 0,,, Power input () (E) kw,,9,,,, COP () (E),9,,,9,, Eurovent efficiency class C B B C B A Water flow () l/h Water pressure drop () (E) kpa 0 Available pressure head - standard pump () kpa Maximum current absorption A Startup current A Startup current with softstarter kit A 0 No. of compressors / circuits / / / / / / Expansion vessel dm Buffer tank volume dm Sound power level () (E) db(a) Transport weight unit with pump and tank kg Operating weight unit with pump and full tank kg 0 () Water temperature / C, outdoor air temperature C (UNI EN :0) () Water temperature 0/ C, outdoor air temperature C D.B. / C W.B. (UNI EN :0) () Sound power level measured according to UNI EN ISO 9 (E) EUROVENT certified data VM000-C
6 MPE - kw Rated technical data MPE-H Power supply V-ph-Hz 00-N-0 00-N-0 00-N-0 00-N-0 00-N-0 00-N-0 00-N-0 Cooling capacity () (E) kw,9, 0,,0,,, Power input () (E) kw 9,, 0,,,0,, EER () (E),,0,9,90,9,, ESEER (E),9,0,,,,0,0 Eurovent efficiency class C B B B B C D Water flow () l/h Water pressure drop () (E) kpa Available pressure head - standard pump () kpa 0 9 Heating capacity () (E) kw 0,,,9 9,,,, Power input () (E) kw 9, 9, 0,,9,,9, COP () (E),0,,,,,,9 Eurovent efficiency class A A A A A A B Water flow () l/h Water pressure drop () (E) kpa 0 Available pressure head - standard pump () kpa Maximum current absorption A Startup current A Startup current with softstarter kit A No. of compressors / circuits / / / / / / / Expansion vessel dm Buffer tank volume dm 0 Sound power level () (E) db(a) Transport weight unit with pump and tank kg Operating weight unit with pump and full tank kg MPE-H T0 T T0 T T T T9 T Power supply V-ph-Hz 00-N-0 00-N N-0 00-N-0 00-N-0 00-N-0 Cooling capacity () (E) kw 9,,,,, 0,,, Power input () (E) kw 0,,,9,,,,0,0 EER () (E),,9,,9,,,, ESEER (E),09,0,0,9,0,0,, Eurovent efficiency class C D C D C C C D Water flow () l/h Water pressure drop () (E) kpa 9 0 Available pressure head - standard pump () kpa 9 9 Heating capacity () (E) kw, 9,,, 0,,, Power input () (E) kw,,,, 9,0,,9, COP () (E),,0,,,9,0,, Eurovent efficiency class B B A B B B A B Water flow () l/h Water pressure drop () (E) kpa 9 9 Available pressure head - standard pump () kpa Maximum current absorption A 9 Startup current A Startup current with softstarter kit A No. of compressors / circuits / / / / / / / / Expansion vessel dm Buffer tank volume dm Sound power level () (E) db(a) Transport weight unit with pump and tank kg Operating weight unit with pump and full tank kg Air chillers and heat pumps - MPE () Water temperature / C, outdoor air temperature C (UNI EN :0) () Water temperature 0/ C, outdoor air temperature C D.B. / C W.B. (UNI EN :0) () Sound power level measured according to UNI EN ISO 9 (E) EUROVENT certified data VM000-C
7 Air chillers and heat pumps MPE Dimensional drawings MPE libero da ostacoli clear area m m libero da ostacoli clear area LEGEND Water inlet " female Water outlet " female Safety valve discharge outlet provided with rubber ring holder Water supply ½" male (optional tap) Water drainage ½" female Power supply Ø mm Electric control board Fastening points for vibration dampers (accessory) VM000-C
8 MPE - kw Dimensional drawings MPE MMINA MINA ICUREZZA CON PORTAGOMMA A /" MASCHIO (RUBINETTO OPTIONAL) EMMINA RICA Ø m libero da ostacoli clear area libero da ostacoli clear area Air chillers and heat pumps - MPE LEGEND Water inlet " female Water outlet " female Safety valve discharge outlet provided with rubber ring holder Water supply ½" male (optional tap) Water drainage ½" female Power supply Ø mm Electric control board Vibration dampers VM000-C 9
9 Air chillers and heat pumps MPE Dimensional drawings MPE ENTRATA ACQUA /" FEMMINA USCITA ACQUA /" FEMMINA SCARICO VALVOLA DI SICUREZZA CON PORTAGOMMA ALIMENTAZIONE ACQUA /" MASCHIO (RUBINETTO OPTIONAL) ENTRATA ACQUA /" FEMMINA SCARICO ACQUA /" FEMMINA USCITA ACQUA /" FEMMINA ALIMENTAZIONE ELETTRICA Ø SCARICO VALVOLA DI SICUREZZA CON PORTAGOMMA QUADRO ELETTRICO ALIMENTAZIONE ACQUA /" MASCHIO (RUBINETTO OPTIONAL) ANTIVIBRANTI SCARICO ACQUA /" FEMMINA ALIMENTAZIONE ELETTRICA Ø QUADRO ELETTRICO ANTIVIBRANTI m oli stac da o r area o r e lib clea m oli stac a o a ro d are libe clear LEGEND 0 Water inlet " ¼ female Water outlet " ¼ female Safety valve discharge outlet provided with rubber ring holder Water supply ½" male (optional tap) Water drainage ½" female Power supply Ø mm Electric control board Vibration dampers VM000-C
10 MPE - kw Dimensional drawings MPE 0 - MPE T0 T NA A CON PORTAGOMMA ASCHIO (RUBINETTO OPTIONAL) MPE- CON SERBATOIO MPE 0- T MPE - CON SERBATOIO MPE 0- T ENTRATA ACQUA /" FEMMINA USCITA ACQUA /" FEMMINA SCARICO VALVOLA DI SICUREZZA CON PORTAGOMMA ALIMENTAZIONE ACQUA /" MASCHIO (RUBINETTO OPTIONAL) SCARICO ACQUA /" FEMMINA ALIMENTAZIONE ELETTRICA Ø QUADRO ELETTRICO ANTIVIBRANTI m m m m Air chillers and heat pumps - MPE LEGEND Water inlet " ¼ female Water outlet " ¼ female Safety valve discharge outlet provided with rubber ring holder Water supply ½" male (optional tap) Water drainage ½" female Power supply Ø mm Electric control board Vibration dampers VM000-C
11 Air chillers and heat pumps MPE Dimensional drawings MPE ENTRATA ACQUA IMPIANTO " FEMMINA USCITA ACQUA IMPIANTO" FEMMINA SCARICO VALVOLA DI SICUREZZA CON PORTAGOMMA ALIMENTAZIONE ACQUA /" MASCHIO SCARICO ACQUA / "FEMMINA CQUA IMPIANTO " FEMMINA ALIMENTAZIONE ELETTRICA QUA IMPIANTO" FEMMINA ALVOLA DI SICUREZZA CON PORTAGOMMA QUADRO ELETTRICO ZIONE ACQUA /" MASCHIO PUNTI FISSAGGIO ANTIVIBRANTI (ACCESSORIO) CQUA / "FEMMINA 9 INGRESSO ACQUA DESURRISCALDATORE " FEMMINA ZIONE ELETTRICA 0 USCITA ACQUA DESURRISCALDATORE "FEMMINA LETTRICO AGGIO ANTIVIBRANTI (ACCESSORIO) ACQUA DESURRISCALDATORE " FEMMINA CQUA DESURRISCALDATORE "FEMMINA m m m m LEGEND Water inlet " female Water outlet " female Safety valve discharge outlet provided with rubber ring holder Water supply ½ male Water drainage ½" female Power supply Electric control board Fastening points for vibration dampers (accessory) 9 Desuperheater water inlet female 0 Desuperheater water outlet female VM000-C
12 MPE - kw Dimensional drawings MPE T T pianto " femmina pianto " femmina pianto / " femmina elettrica io antivibranti m m Air chillers and heat pumps - MPE LEGEND Water inlet " female Water outlet " female Water drainage ½" female Power supply Electric control board Fastening points for vibration dampers VM000-C
MPI DC 8-29 kw. Outdoor monobloc unit with BLDC compressor. Air chillers and heat pumps MPI DC PLUS
Air chillers and heat pumps MPI DC Outdoor monobloc unit with BLDC compressor MPI DC - 9 kw Large operating range and energy efficiency under every condition BLDC scroll compressor PLUS BLDC rotary compressor
More informationMotor-driven condensing units MTE MTE R-410A
Motor-driven condensing units MTE Outdoor motor-driven condensing units MTE - 0 kw Efficiency and compactness for commercial air conditioning Scroll compressor PLUS R-0A R-0A refrigerant Cooling only Split
More informationLCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS
Total heat recovery multi-purpose units LCP Outdoor monobloc air-water unit LCP - kw Heating, cooling, domestic hot water one single system to meet all kinds of needs. Total heat recovery multi-purpose
More informationHIWARM COMPACT kw
Total heat recovery multi-purpose s HIWRM COMPCT Outdoor monobloc air-water with BLDC compressor HIWRM COMPCT - kw Total recovery and energy efficiency in every condition Total heat recovery multi-purpose
More informationTOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS
TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS Energy saving thanks to a total recovery p Cooling Heating/DHW h Galletti multi-purpose heat pumps are total recovery units used for a simultaneous hot and
More informationGalletti Water chillers and heat pumps catalogue
Galletti www.galletti.it Water chillers and heat pumps catalogue Table of Contents/SMALL SYSTEMS MPI DC Water chillers and heat pumps with inverter compressor 6 models page 6 MCE MPE Air condensed water
More informationLEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS
Total heat recovery multi-purpose units LEP Indoor monobloc water-water unit LEP 50-40 kw Maximum efficiency with total recovery and dissipation in water. Total heat recovery multi-purpose unit Multi-purpose
More informationHIWARM kw. Air-water system with external and internal BLDC unit. Total heat recovery multi-purpose units HIWARM PLUS
Total heat recovery multi-purpose units HIWARM Air-water system with external and internal BLDC unit HIWARM - kw The perfect combination between multi-purpose, inverter technology and style Multi-purpose
More informationLER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS
Indoor motor-driven evaporating units LER 0-0 kw Compact and silent machines with remote dissipation into the air Scroll compressor PLUS R-0A R-0A refrigerant Cooling only Split version Electronic expansion
More informationTECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE
GB TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE 5 kw - 213 kw TABLE OF CONTENTS 1 The series...4 2 Constructive features...4 3 Layout of components...5 4 Models and configurations...13 5 Technical
More informationTECHNICAL MANUAL FOR CHILLERS AND HEAT PUMPS MPE
EN TECHNICAL MANUAL FOR CHILLERS AND HEAT PUMPS MPE 4 kw - 76 kw Air condensed water chillers and heat pumps PERFORMA MPE series eco R410A MPE TABLE OF CONTENTS 1 The series...4 2 Constructive features...5
More informationTECHNICAL MANUAL MCP. Multipurpose - total heat recovery reversible heat pumps. 7 kw - 41 kw
GB TECHNICAL MANUAL MCP Multipurpose - total heat recovery reversible heat pumps 7 kw - 41 kw TABLE OF CONTENTS 1 The Series...4 2 Constructive features...7 3 Layout of components...8 4 Technical characteristics...18
More informationTECHNICAL MANUAL FOR CHILLERS AND HEAT PUMPS MPE D
EN TECHNICAL MANUAL FOR CHILLERS AND HEAT PUMPS MPE D 7 kw - 76 kw DUCTABLE VERSION Air condensed duct water chillers and heat pumps PERFORMA MPE series eco R410A MPED TABLE OF CONTENTS 1 The series...4
More informationAir Cooled Chillers & Heat Pumps WinPACK HE-A
Air Cooled Chillers & Heat Pumps WinPACK HE-A TCAEY-THAEY 2110-4340 1 Air Cooled Chillers & Heat Pumps WinPACK HE-A TCAEY-THAEY 2110-4340 Cooling capacity: 91,6-345 kw Heating capacity: 110,5-357 kw Class
More informationGPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1
UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A
More informationAIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES
AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES COOLING CAPACITY FROM 76 TO 612 Kw 1 AND 2 COOLING CIRCUITS RAE 1702 F Kc + P2 28 Above picture is only indicative
More informationCMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N
E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,
More informationKälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10
Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW Compressors Scroll Serie: Series: Emissione: Issue: SCAEY Catalogo: Leaflet: Sostituisce: Supersedes: DE 88 04/11 12/10 Index
More informationPRODUCT GUIDE
PRODUCT GUIDE 01.2017 Cooling Heating CHAPTER 1 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Power (kw) Page IACAK/II/WP 101.5 106 0 58 115 A CLASS energy efficiency
More informationV-IPER. Installation, use and maintenance manual. Chillers and heat pumps 50 kw kw PLUS
Installation, use and maintenance manual EN V-IPER Chillers and heat pumps 50 kw - 380 kw Double class A Eurovent Refrigerant R-410A Cooling only Heating/ Cooling Monoblock execution Axial fans Hydro smart
More informationKälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98
Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw Scroll Compressors Series: SCAEY-FC Leaflet: DE 98 Issue: 01/16 Supersedes: 12/13 Identification code Index Index... pag. 2 Identification code...»
More informationBRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.
More information
AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw
COMFORT CHILLERS AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com COMFORT CHILLERS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air-cooled liquid chiller for outside installation
More informationi-nrg 0061m 0061t Reversible heat pump with inverter compressor, total heat recovery, air source for indoor/outdoor installation 16,3 kw PRANA
RANA i-nrg 0061m 0061t Versioni i-nrg Reversible heat pump with inverter compressor, total heat recovery, air source for indoor/outdoor installation Features Reversible heat pump with inverter compressor,
More informationMULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw
Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01
More informationRAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR
AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 46 Above picture is only indicative and is not binding AIR FC The packaged air cooled chillers of RAS Kp series are suitable
More informationModular Air-cooled Chillers
Modular Air-cooled Chillers High Seasonal Efficiency (HSE) version Cooling capacity 48-232 kw Trane Flex Series Modular air/water chillers with axial EC fans, inverter driven scroll compressors and microchannel
More informationRMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL
RMA ECO-FRIENDLY REFRIGERANT GAS AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the
More informationAIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS
RAE 1352 F.K + MV AIR R-407C FC Series RAE... F.K Cooling capacity from 77 to 289 kw - 2 circuits The air cooled chillers of RAE... F.K series, are designed for outdoor installation and are particularly
More informationMulti-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw
Multi-pipe Units with Scroll Compressors Model CMAA Cooling capacity 45-485 kw Heating capacity 50-670 kw CMAA multi-pipe units Simultaneous heating and cooling with one product Standard versions Acoustic
More informationAIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw
PROCESS CHILLERS AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com PROCESS CHILLERS MAXIMUM EFFICIENCY IN EVERY TYPE OF PROCESS APPLICATION Air cooled liquid chiller for outdoor
More informationCMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL
CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years
More informationEKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata
EKS/HE Refrigerant R410A GWP=2.088 Scroll Compressor Shell & Tube exchanger Axial fan Brazed plate heat exchanger MultiScroll Air-cooled liquid chillers High efficiency Solution B - Base I - Integrata
More informationPackaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB
Packaged air cooled liquid chillers for outdoor installation 42 574 kw technicalcatalogue T_EGL_1012_GB INDEX EUROVENT CERTIFICATION... 3 GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION...
More informationLSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES
LS ir cooled water chillers with axial fans + LS The LS water chiller range has been designed for small and medium residential and commercial applications. They are suitable for generating chilled water
More informationSMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB
T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING
More information> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories
> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION Available range Unit type IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS Versions (heat recovery) VB Base
More informationEpsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points
Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique
More informationSLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual
u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications
More informationAQUASNAP JUNIOR 30RHV
High-Efficiency Air-To-Water Heat Pumps Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. AQUASNAP JUNIOR 3RHV 6-11
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are
More informationBETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.
Air/water cooled chillers and heat pumps 41 303 kw General BETA ECHOS is a range of chillers and ductable air-water heat pumps. Configurations HP: Reversible heat pump LE: For connection to remote evaporator
More informationBRH. Climaveneta Technical Bulletin. Water-cooled liquid chillers ,5-35,1 kw. Versatile High efficiency Maximum silent-running
Climaveneta Technical Bulletin BRH_0011_0121_201211_EN BRH r HFC R-410A 0011-0121 5,5-35,1 kw Water-cooled liquid chillers (The photo of the unit is indicative and may change depending on the model) Versatile
More informationAIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw
COMFORT HEAT PUMPS AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw climaveneta.com COMFORT HEAT PUMPS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air to water heat pump for outdoor installation,
More informationKälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98
Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw Scroll Compressors Series: SCAEY-FC Leaflet: DE 98 Issue: 04/11 Supersedes: 12/10 Identification code Index Index... pag. 2 Identification code...»
More informationEASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB
R407C EASY_R Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans 5,2 41,5 kw T_ESY_R_0508_GB EASY_R R407C INDEX WORKING LIMITS... 3 SERIES IDENTIFICATION... 4 MODEL
More informationkw COOLING kw HEATING
Heat pump water/water liquid chillers for indoor installation. Inversion on hydraulic circuit. 394 1505 kw COOLING 477 1976 kw HEATING technicalcatalogue T_FRGSCRWP_0913_GB INDEX GENERAL CHARACTERISTICS...
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are
More informationRAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS
AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.
More informationLZA High efficiency air to water heat pumps with HP compressor
High efficiency air to water heat pumps with HP compressor -10 C +43 C +60 C HP C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems
More informationpyxis u pyxis ua NEW rcgroupairconditioning
Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 44,9 200,0 rcgroupairconditioning R410 C PLTE
More informationTechnical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz
EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the
More informationPYXIS U PYXIS U. rcgroupairconditioning
Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 44 284 rcgroupairconditioning MIN FETURES
More informationSA 1 INDEX Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R410A...pag. 5 Scroll compressors...pag. 6 Condenser coils...pag. 6 Brazed
More informationpyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning
Comfort PYXIS HP U : ir / water reversible heat pumps for outdoor installation, equipped with scroll compressors and axial fans Cooling Capacity: 42,3 195,0 Heating Capacity: 47,1 222,0 NEW IDE R410 rcgroupairconditioning
More informationConstruction details: Structure and base in hot dip galvanised sheet steel with epoxy pain finish (RAL 9002)
Water cooled internal chiller and heat pump units with scroll compressors Cooling capacity from 106 kw to 385 kw NXW Heating capacity from 119 kw to 419 kw R410A Aermec participates in the EUROVENTProgram:
More informationLZT High efficiency air to water heat pumps with E.V.I. compressors
High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating
More informationGLIDER EVO GLIDER EVO. rcgroupairconditioning
: Packaged air cooled liquid chillers for outdoor installation equipped with screw compressors and axial fans Cooling Capacity: 300 1313 rcgroupairconditioning R134a SHELL C MIN FETURES ir cooled liquid
More informationRTA TECHNICAL MANUAL AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L S E A F RA N
A RE F S E -FRIEND Y R E IG RA N T G AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L RTA C TECHNICAL MANUAL 1 2 SUMMARY THIS MANUAL IS DIVIDED INTO SECTIONS. THEIR NAMES APPEAR IN THE HEADING
More informationHYDRONIC RESIDENTIAL
HYDRONIC RESIDENTIAL Chillers, reversible heat pumps and modular units for small and medium applications. Climaveneta. brand of Mitsubishi Electric Hydronics & IT Cooling Systems, presents the mini chiller
More informationGLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning
: Packaged air cooled liquid chillers with free-cooling system for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 314 1343 Free-Cooling Capacity: 308 938 GLYCOL
More informationMCC 1 THE RANGE INDEX
Water chillers and heat pumps TECHNICAL MANUAL GB INDEX 1 The range... 2 2 Constructive features... 3 3 Components lay-out... 5 4 Models and configurations... 6 5 Rated technical data... 7 5.1 Cooling
More informationpyxis pyxisa NEW rcgroupairconditioning
Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 119,0 808,0 PLTE C rcgroupairconditioning
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationSPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw
SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:
More informationO L R E RGA ST RA N AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION TECHNICAL MANUAL
-FRIEND A R E IG RA N T G RGA ST RE F S Y E O L C AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION TECHNICAL MANUAL 1 2 SUMMARY THIS MANUAL IS DIVIDED INTO SECTIONS. THEIR NAMES APPEAR IN THE
More informationGLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning
GLIDER EVO CL GLIDER EVO CL: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 282 1513 HIGHEFFICIENCY
More informationAir cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw
Air cooled chillers with brushless oil-free compressors R-134a RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw External installation with very low sound level Cooling circuit with
More informationCZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with
More informationCRIMSON & CRIMSON MAX
High efficiency water/water and geothermal heat pumps 5 114 General High efficiency water/water and geothermal heat pumps. Ideal for heating, cooling and production of domestic hotwater with total or partial
More informationpyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning
Industrial PYXIS CL: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with scroll compressor and microchannel condensing coils Cooling Capacity: 108 876
More information30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation
Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Quality Management Systems 0RB 008-05 Nominal cooling capacity 8- The new generation of Aquasnap liquid chillers was designed
More informationBRAN. Climaveneta Technical Bulletin BRAN_0011_0121_201211_EN ,6-31,3 kw. Reversible unit, air source for outdoor installation
Climaveneta Technical Bulletin BRAN_0011_0121_201211_EN BRAN r HFC R-410A 0011-0121 4,6-31,3 kw Reversible unit, air source for outdoor installation (The photo of the unit is indicative and may change
More informationAir Cooled Chillers & Heat Pumps FullPower HE-A
Air Cooled Chillers & Heat Pumps FullPower HE-A TCAVTZ-TCAVQZ 345-1335 1 Air Cooled Chillers & Heat Pumps FullPOWER HE-A TCAVTZ-TCAVQZ 345-1335 Cooling capacity: 317-1.35 Efficient range in class A Extended
More informationblack Thermal power (A7:W45) kw Cooling power (A35;W7) kw
black Thermal power (A7:W45) 35 60 kw Cooling power (A35;W7) 32 56 kw High efficiency and high temperature air/water heat pump with axial fans and scroll compressors 134a H 2 O 80 CONTROL MINIBOSS black
More informationAquaflair TRAC-TRAF-TRAH
Aquaflair TRAC-TRAF-TRAH 110 400 kw Air-cooled chillers, free-cooling chillers and heat pumps for mission critical applications Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors
More information1
ST www.coldinnovation.it 1 INDEX Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R410A...pag. 5 Scroll compressors...pag. 6 Condenser
More informationWSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES
Water to water chillers and heat pumps The water chillers range have been designed for small and medium residential and commercial applications. The water chillers are suitable for water outlet temperatures
More informationБольшая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.
Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive,
More information44,9 202,0 kw. technicalcatalogue
Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressor and microchannel condensing coils 44,9 202,0 kw technicalcatalogue T_PYXU_0413_GB INDEX EUROVENT CERTIFICATION...
More informationnemo a hp rcgroupairconditioning R410A
NEMO A HP: Motoevaporating heat pumps for indoor installation, equipped with scroll compressor and plate heat exchanger Cooling Capacity: 5,5 25,0 Heating Capacity: 6,4 29,3 nemo a hp PLATE rcgroupairconditioning
More informationEREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY
Easy and fast installation Hydronic module available Compact, reliable and efficient Nominal cooling capacity : 8-40 kw Nominal heating capacity : 17-40 kw 50 410A Cooling or heating USE The air-to-water
More informationBlue Box Epsilon Echos +
Blue Box Epsilon Echos + 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Packaged version in 5 sizes Nominal cooling capacity (A35;W7): 6 26 kw Nominal heating
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02
More informationH4T R410A. refrigerant
H4T INDEX Polyvalent unit working modes...pag. 4 Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R410A...pag. 5 Scroll compressors...pag.
More informationNRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER
NRP MULTIPURPOSE HEAT PUMPS AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER Multipurpose air cooled units with axial fans. For external installation. High efficiency version. NRP MULTIPURPOSE
More informationAQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual
u Air-to-Water Reverse Cycle Heat Pumps AQH 40 to 130 40 to 131 kw 45 to 141 kw Engineering Data Manual EDM AQH-W.3GB Date : November 2007 Supersedes : TM AQH-W.2GB/03.04 Specifications The Aqu@Logic air-to-water
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -
More information30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw
Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The
More informationglider evo cla glider evo cla A-CLASS rcgroupairconditioning
Industrial GLIDER EVO CL: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 284 1513 -CLSS rcgroupairconditioning
More informationNeosys Product catalogue
00/0 Neosys Product catalogue Providing indoor climate comfort NEOSYS 00 0 kw Air cooled chiller/heat pump YEAR WARRANTY* Quality makes the difference* Introduction to the range NEOSYS is providing chilled
More informationkw. technicalcatalogue
Packaged air cooled liquid chillers in A class energy efficiency for outdoor installation equipped with scroll compressor and microchannel condensing coils 108 876 kw technicalcatalogue T_PYXCLA_0413_GB
More informationDYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers
High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER
More informationHeat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications
Heat Pump Technology Air Source, Water Source and Ground Source Optimised heat pumps for residential and commercial applications ICS Cool Energy Limited has nearly 25 years experience in supplying and
More information30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump
PRODUCT SELECTION DATA Monobloc inverter Compact, reliable and efficient More than a Heat Pump Reversible Air to Water Heat Pump 0AW CARRIER participates in the ECP programme for LCP/HP Check ongoing validity
More information30RQV NEW. Nominal cooling capacity kw Nominal heating capacity kw AIR-TO-WATER HEAT PUMPS HEATING. Easy and fast installation
AIR-TO-WATER HEAT PUMPS 30RQV 017-021 NEW Nominal cooling capacity 15-18 kw Nominal heating capacity 17-21 kw greenspeed Easy and fast installation Hydronic module available Inverter technology compressor
More informationCHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw
TECHNICAL INSTRUCTIONS CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw CHG 1 CHG 1 8. kw. kw.7 kw 1. kw April 7 19 - GB - 2 MARKING This product marked conforms to the essential
More informationNECS-N. Climaveneta Technical Bulletin. Reversible unit, air source for outdoor installation. 0202T T kw
Climaveneta Technical Bulletin NECS_N_0202T_0612T_201007_GB r HFC R-410A 0202T - 0612T 53-159 kw Reversible unit, air source for outdoor installation (The photo of the unit is indicative and may change
More informationAquaflair. Residential and Industrial Cooling Systems
Aquaflair Residential and Industrial Cooling Systems Uniflair Europe SpA Viale della Tecnica, 2 35026 Conselve (Pd) Italy Tel. +39 049 5388211 Fax +39 049 5388212 info@uniflair.com uniflair.com Company
More informationEQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM
TECHNICAL CATALOGUE EQEF Water Chillers with Free Cooling System Models:60.1 60.2 70.1 70.2 90.1 90.2 120.1 120.2 135.1 150.1 190.2 200.1 200.2 240.2 270.2 300.2 Cooling capacities: 69,7 to 331 KW 02.16
More information