P1DD AND G8D 2-STAGE DOWNFLOW - NATURAL GAS FURNACES (80%)
|
|
- Buck Grant
- 5 years ago
- Views:
Transcription
1 P1DD AND G8D 2-STAGE DOWNFLOW - NATURAL GAS FURNAES (80%) HVA SERVIE PARTS Supersedes: Rev. (0404) Rev. D (0604) 1 of 8 Figure 1: 2-STAGE DOWNFLOW NATURAL GAS FURNAES (80%) P1DDA12N04801 P1DDA12N06401 P1DDB16N06401 FIG ITEM DESRIPTION G8D06012DNA11 G8D08012DNA11 G8D08016DNB11 (3 BURNER) (4 BURNER) (4 BURNER) MOTOR 1 1 MOTOR,DIRET DRIVE BLOWER MOTOR,VENTOR ASS Y ELETRIAL 1 3 APAITOR (7.5MFD/370V) [R] APAITOR (10MFD/370V) [R] ONTROL, HIGH LIMIT [LS1] ONTROL,FURNAE [F] IGNITOR ,2 7 SENSOR, FLAME SWITH, AIR PRESSURE [1LP] SWITH, DOOR [SW] TRANSFORMER ,2 11 VALVE, GAS ,2 12 ONTROL, LIMIT (Blower) (2 Req d) [ROS1] ONTROL, AUXILARY LIMIT [LS2] TIMER, 2 STAGE * 15 FUSE AIR MOVING 1 16 HOUSING, BLOWER WHEEL, BLOWER NOTE: *Not Shown New replacement parts shown in bold face type at the first printing of parts list dated 6/04. Major components and suggested stocking items are shown with shaded item number. < Across from row indicates a change in that row. --- Not applicable to specified model. Unitary Products Group
2 Rev. D (0604) 2 of 8 2-STAGE DOWNFLOW NATURAL GAS FURNAES (80%) FIG ITEM DESRIPTION P1DDA12N04801 P1DDA12N06401 P1DDB16N06401 G8D06012DNA11 G8D08012DNA11 G8D08016DNB11 (3 BURNER) (4 BURNER) (4 BURNER) FABRIATED PARTS 1 18 SHIELD, SEONDARY AIR * 19 BAFFLE, FLUE ,2 20 BURNER, MAIN GAS BRAKET, IGNITOR DEK, BLOWER (Rear) DEK, FRONT HEAT EXHANGER ASS Y (Primary) ,2 25 MANIFOLD, GAS PANEL, FRONT (Burner) PANEL, BASE BRAKET, DOOR PANEL, FRONT (Blower) PANEL, TOP WRAPPER, INSULATED * 32 FILTER (2 Req d) (1 X 14 X 20) PLUG, WINDOW, LEAR * 34 BRAKET, FILTER GASKET, VENT PIPE BRAKET, ROLL-OUT SWITH MISELLANEOUS 1,2 37 ORIFIE, BURNER (Natural #45) PLATE, RESTRITOR OLLAR, FLUE HANDLE, DOOR * 41 GASKET, RESTRITOR PLATE TUBING, SILIONE * 43 WIRING DIAGRAM < * 44 WIRING HARNESS < 1 45 HOUSING FLUE VENT PIPE RETAINER, INSULATION * 48 MOTOR MOUNT * 49 ISOLATOR, TUBE (3 Req d) * 50 ISOLATOR, WASHER (3 Req d) * 51 ISOLATOR,SLEEVE (3 Req d) NOTE: *Not Shown New replacement parts shown in bold face type at the first printing of parts list dated 6/04. Major components and suggested stocking items are shown with shaded item number. < Across from row indicates a change in that row. --- Not applicable to specified model.
3 3 of Rev. D (0604) Figure 1: 2-STAGE DOWNFLOW NATURAL GAS FURNAES (80%) FIG ITEM MOTOR DESRIPTION P1DDB12N08001 P1DD20N09601 G8D10012DNB11 G8D12020DN11 (5 BURNER) (6 BURNER) 1 1 MOTOR,DIRET DRIVE BLOWER MOTOR,VENTOR ASS Y ELETRIAL 1 3 APAITOR (7.5MFD/370V) [R] APAITOR (15MFD/370V) [R] ONTROL, HIGH LIMIT [LS1] ONTROL,FURNAE [F] IGNITOR ,2 7 SENSOR, FLAME SWITH, AIR PRESSURE [1LP] SWITH, DOOR [SW] TRANSFORMER ,2 11 VALVE, GAS ,2 12 ONTROL, LIMIT (Blower) (2 Req d) [ROS1,2] ONTROL, AUXILARY LIMIT TIMER, 2 STAGE * 15 FUSE AIR MOVING 1 16 HOUSING, BLOWER WHEEL, BLOWER NOTE: *Not Shown New replacemnt parts shown in bold face type at the first printing of parts list code dated 6/04. Major components and suggested stocking items are shown with shaded item number < Across from row indicates a change in that row. --- Not applicable to specified model. Unitary Products Group
4 Rev. D (0604) 4 of 8 ) 2-STAGE DOWNFLOW NATURAL GAS FURNAES (80%) FIG ITEM DESRIPTION P1DDB12N08001 P1DD20N09601 G8D10012DNB11 G8D12020DN11 (5 BURNER) (6 BURNER) FABRIATED PARTS 1 18 SHIELD, SEONDARY AIR * 19 BAFFLE, FLUE ,2 20 BURNER, MAIN GAS BRAKET, IGNITOR DEK, BLOWER (Rear) DEK, FRONT HEAT EXHANGER ASS Y (Primary) ,2 25 MANIFOLD, GAS PANEL, FRONT (Burner) PANEL, BASE BRAKET, DOOR PANEL, FRONT (Blower) PANEL, TOP WRAPPER, INSULATED * 32 FILTER (2 Req d) (1 X 14 X 20) PLUG, WINDOW, LEAR * 34 BRAKET, FILTER GASKET, VENT PIPE ,2 36 BRAKET, ROLL-OUT SWITH MISELLANEOUS 1,2 37 ORIFIE, BURNER (Natural #45) PLATE, RESTRITOR OLLAR, FLUE HANDLE, DOOR * 41 GASKET, RESTRITOR PLATE TUBING, SILIONE * 43 WIRING DIAGRAM * 44 WIRING HARNESS HOUSING, FLUE VENT PIPE RETAINER, INSULATION * 48 MOTOR MOUNT * 49 ISOLATOR, TUBE (3 Req d) * 50 ISOLATOR, WASHER (3 Req d) * 51 ISOLATOR,SLEEVE (3 Req d) NOTE: *Not Shown New replacement parts shown in bold face type at the first printing of parts list dated 6/04. Major components and suggested stocking items are shown with shaded item number. < Across from row indicates a change in that row. --- Not applicable to specified model.
5 5 of Rev. D (0604) Figure 2: GAS ONTROLS Unitary Products Group
6 Rev. D (0604) 6 of 8 FIELD INSTALLED AESSORIES - NON ELETRIAL MODEL NO. DESRIPTION USED WITH 1NP0480 PROPANE (LP) ONVERSION KIT ALL MODELS 1PS0301 1PS0302 1PS0311 1PS0312 1BR0314 1BR0317 1BR0321 1BR0324 1B0314 1B0317 1B0321 1B0324 HIGH ALTITUDE PRESSURE SWITH KIT (Does Not Include Orifices) EXTERNAL BOTTOM RETURN FILTER OMBUSTIBLE FLOOR BASE FOR DOWNFLOW UNITS SEE TABLE BELOW 14-1/2 ( A ) ABINETS 17-1/2 ( B ) ABINETS 21 ( ) ABINETS 24-1/2 ( D ) ABINETS 14-1/2 ( A ) ABINETS 17-1/2 ( B ) ABINETS 21 ( ) ABINETS 24-1/2 ( D ) ABINETS 1SR0302 EXTERNAL SIDE FILTER RAK - WITH FILTER RAK (6 pack) ALL MODELS FIELD INSTALLED AESSORIES - ELETRIAL MODEL NO. DESRIPTION USED WITH 2TH TB TH ET THERMOSTAT-Two-stage Heat / ool, deluxe 24V, less subbase. NOTE: Must be used with subbase 2TB SUBBASE- Two-stage Heat / ool, Auto or manual changeover. System Switch: Off-Heat-Auto-ool. Fan Switch: Auto-On. Isolated Heat/ool circuits. THERMOSTAT- Two-stage Heat / ool, Auto or manual changeover. SystemSwitch: Heat-Off-ool-Auto. Fan Switch: On-Auto. THERMOSTAT-Two-stage Heat / ool. Programmable electronic (5+1+1), Auto or manual changeover. System Switch:Heat-Off-ool-Auto. Fan Switch: Auto-On. ALL P1D MODELS ALL P1D MODELS ALL P1D MODELS ALL P1D MODELS 2T TWINNING ONTROL 6ET ET ET ET ET THERMOSTAT- Hardwired, 2 Heat / 2 ool. Programmable, auto changeover. System Switch: ool-off-heat. Fan Switch: Auto-On THERMOSTAT- Hardwired, 1 Heat / 1 ool. Manual changeover. System Switch: ool-off-heat. Fan Switch: Auto-On THERMOSTAT- Hardwired, 1 Heat / 1 ool. Programmable, auto changeover. System Switch: ool-off-heat. Fan Switch: Auto-On THERMOSTAT- Power Stealing, 1 Heat / 1 ool. Programmable, auto changeover. System Switch: ool-off-heat. Fan Switch: Auto-On THERMOSTAT- Power Stealing, 1 Heat / 1 ool. Manual changeover. System Switch: ool-off-heat. Fan Switch: Auto-On Input (MBH) Output (MBH) HIGH PRESSURE SWITH 2,000 Ft. to 5,500 Ft. >5,500 Ft. to10,000 Ft PS0301 1PS PS0301 1PS PS0302 1PS PS0312 1PS PS0312 1PS PS0312 1PS0311
7 7 of Rev. D (0604) NOTES Unitary Products Group
8 8 of 8 TO ORDER AUTHORIZED FATORY REPLAEMENT PARTS - ontact your Source1 HVA Parts Distributor or visit our website at for a Distributor and Dealer listing. Subject to change without notice. Printed in U.S.A Rev. D (0604) opyright by York International orp All rights reserved. Supersedes: Rev. (0404) Unitary 5005 Norman Products York OK Group Drive 73069
2-STAGE UPFLOW/HORIZONTAL MID-EFFICIENCY NATURAL GAS FURNACES - (80%)
2-STAGE UPFLOW/HORIZONTAL MID-EFFICIENCY NATURAL GAS FURNACES - (80%) INCLUDING LO-NOX (See Page 6) HVAC SERVICE PARTS Supersedes: 035-17432-000 Rev. B (1201) 035-17432-000 Rev. C (0304) 1 of 8 Figure
More information2 STAGE UPFLOW NATURAL GAS FURNACES (94+)
2 STAGE UPFLOW NATURAL GAS FURNACES (94+) HVAC SERVICE PARTS Supersedes: 035-17482-000 Rev. E (1102) 035-17482-000 Rev. F (0304) 1 of 8 Figure 1: 2-STAGE UPFLOW NATURAL GAS FURNACES (94+) P1XUB12N05501
More informationPT9 SERIES - UPFLOW 2-STAGE NATURAL GAS FURNACE - 90% (STYLE A)
www.source1parts.com HVAC SERVICE PARTS PT9 SERIES - UPFLOW 2-STAGE NATURAL GAS FURNACE - 90% (STYLE A) Supersedes: 035-20487-001 Rev. C (1004) 035-20487-001 Rev. D (1014) 1 of 8 31 65 24 5 8 53 63 35
More informationPS9 SERIES - UPFLOW 1-STAGE NATURAL GAS FURNACE - 90%
PS9 SERIES - UPFLOW 1-STAGE NATURAL GAS FURNACE - 90% HVAC SERVICE PARTS Supersedes: 035-20437-001 Rev. C (1004) 035-20437-001 Rev. D (1204) 1 of 8 Figure 1: UPFLOW 1-STAGE NATURAL GAS FURNACES (90%) FIG
More informationUPFLOW NATURAL GAS FURNACES - 90%
Y W R G C UPFLOW NATURAL GAS FURNACES - 90% www.source1parts.com HVAC SERVICE PARTS Supersedes: 035-17489-000 Rev. C (1201) 035-17489-000 Rev. D (302) 1 of 8 13 5 8 10 4 2 9 6 14 11 1 COOL HEAT CIR 12
More informationFG9 - STYLES A AND B UPFLOW NATURAL GAS FURNACES (90%)
FG9 - STYLES A AND B UPFLOW NATURAL GAS FURNACES (90%) www.source1parts.com HVAC SERVICE PARTS Supersedes: 650.75-RP1U (1199) 035-17790-001 Rev. A (1102) 1 of 8 13 5 9 8 61 6 10 4 2 11 12 7 3 16 1 14 15
More informationGM9V SERIES - UPFLOW 2-STAGE VARIABLE SPEED NATURAL GAS FURNACE - 90% (STYLE A)
GM9V SERIES - UPFLOW 2-STAGE VARIABLE SPEED NATURAL GAS FURNACE - 90% (STYLE A) HVAC SERVICE PARTS Supersedes: 035-20642-001 Rev. A (0904) 035-20642-001 Rev. B (0205) 1 of 8 Figure 1: UPFLOW 2-STAGE VARIABLE
More informationPT8 SERIES 2-STAGE UPFLOW/HORIZONTAL 80% NATURAL GAS FURNACES
www.source1parts.com HVAC SERVICE PARTS PT8 SERIES 2-STAGE UPFLOW/HORIZONTAL 80% NATURAL GAS FURNACES (STYLE D, Some B) INCLUDING LO-NOX MODELS Supersedes: Nothing 035-21348-001 Rev. A (0307) 1 of 8 8
More informationFC8T SERIES 2-STAGE UPFLOW/HORIZONTAL NATURAL GAS FURNACES - (80%)
FC8T SERIES 2-STAGE UPFLOW/HORIZONTAL NATURAL GAS FURNACES - (80%) INCLUDING LO-NOX (MODEL LC8) (STYLE B) HVAC SERVICE PARTS Supersedes: 035-20671-001 Rev. C (0605) 035-20671-001 Rev. D (1105) 1 of 8 Figure
More informationP3HU - UPFLOW/HORIZONTAL NATURAL GAS FURNACES - (80%) (STYLES A & B, INCLUDING LOW NOX)
www.source1parts.com HVAC SERVICE PARTS PHU - UPFLOW/HORIZONTAL NATURAL GAS FURNACES - (0%) (STYLES A & B, INCLUDING LOW NOX) Supersedes: 0-1-000 Rev. C (06) 0-1-000 Rev. D (0) 1 of 1 1 1 1 1 6,0 Figure
More informationPS9 SERIES (STYLE C) UPFLOW NATURAL GAS FURNACES - 90%
PS9 SERIES (STYLE C) UPFLOW NATURAL GAS FURNACES - 90% www.source1parts.com HVAC SERVICE PARTS Supersedes: 035-21082-001 Rev. A (1205) 035-21082-001 Rev. B (1106) 1 of 12 31 29 5 61 26 10 39 69 12 11 16
More informationPS9 SERIES (STYLE B) UPFLOW NATURAL GAS FURNACES - 90%
PS9 SERIES (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% HVAC SERVICE PARTS Supersedes: 035-20712-001 Rev. B (1005) 035-20712-001 Rev. C (1105) 1 of 12 Figure 1: UPFLOW NATURAL GAS FURNACES (90%) FIG ITEM
More informationFC9V SERIES - UPFLOW 2-STAGE CONDENSING VARIABLE SPEED NATURAL GAS FURNACES (STYLE A)
www.source1parts.com HVAC SERVICE PARTS FC9V SERIES - UPFLOW 2-STAGE CONDENSING VARIABLE SPEED NATURAL GAS FURNACES (STYLE A) Supersedes: 035-20615-001 Rev. C (1004) 035-20615-001 Rev. D (0507) 1 of 8
More informationFL9M SERIES MODULATING CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE A)
www.source1parts.com HVAC SERVICE PARTS FL9M SERIES MODULATING CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE A) Supersedes: 035-21211-001 Rev. C (1106) 035-21211-001 Rev. D (0708) 1 of 8 33 31 5 10 41
More informationGF9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE G)
www.source1parts.com HVAC SERVICE PARTS 32 GF9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE G) Supersedes: 035-20372-001 Rev. D (0205) 035-20372-001 Rev. E (0507) 74 1 of 12 Figure 1: UPFLOW CONDENSING
More informationPT9 SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90%
PT9 SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% HVAC SERVICE PARTS Supersedes: 035-20714-001 Rev. C (1005) 035-20714-001 Rev. D (1105) 1 of 8 Figure 1: UPFLOW 2-STAGE NATURAL GAS FURNACES
More informationGM9S SERIES CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE K)
GM9S SERIES CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE K) www.source1parts.com HVAC SERVICE PARTS Supersedes: Nothing 035-21295-001 Rev. A (1206) 1 of 12 31 29 26 5 10 39 69 24 11 12 16 58 61 40 13
More informationTECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE
TEHNIAL GUIDE Acclimate MODELS: FL9S GAS-FIRED ONDENSING / HIGH EFFIIENY UPFLOW SINGLE STAGE FURNAES 92% AFUE NATURAL GAS 40-135 MBH INPUT EFFIIENY RATING ERTIFIED ISO 9001 ertified Quality Management
More informationPT9 SERIES DOWNFLOW/HORIZONTAL 2-STAGE NATURAL GAS FURNACE (90%) (STYLE A)
PT9 SERIES DOWNFLOW/HORIZONTAL 2-STAGE NATURAL GAS FURNACE (90%) (STYLE A) HVAC SERVICE PARTS Supersedes: 035-20700-001 Rev. B (0805) 035-20700-001 Rev. C (1105) 1 of 8 Figure 1: DOWNFLOW/HORIZONTAL 2-STAGE
More informationGM9T SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90%
GM9T SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% HVAC SERVICE PARTS Supersedes: 035-20716-001 Rev. A (0205) 035-20716-001 Rev. B (1005) 1 of 8 Figure 1: UPFLOW 2-STAGE NATURAL GAS FURNACES
More informationGM9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE J)
www.source1parts.com HVAC SERVICE PARTS GM9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE J) Supersedes: 035-21080-001 Rev. D (0207) 035-21080-001 Rev. E (0507) 1 of 12 31 29 26 5 10 39 69 24 11
More informationTG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B)
www.source1parts.com HVAC SERVICE PARTS 23 TG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B) Supersedes: 035-23623-001 Rev. A (0313) 035-23623-001 Rev. B (0613) 26 1 of 6 44
More informationFC9V SERIES 2-STAGE CONDENSING VARIABLE SPEED UPFLOW NATURAL GAS FURNACES (STYLE C)
www.source1parts.com HVAC SERVICE PARTS FC9V SERIES 2-STAGE CONDENSING VARIABLE SPEED UPFLOW NATURAL GAS FURNACES (STYLE C) Supersedes: 035-21088-001 Rev. B (0806) 035-21088-001 Rev. C (0507) 1 of 8 31
More informationTG8S SERIES 80% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE A) INCLUDES LO-NOX MODELS TGLS
www.source1parts.com HVAC SERVICE PARTS 41 TG8S SERIES 80% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE A) INCLUDES LO-NOX MODELS TGLS Supersedes: 035-21389-001 Rev. K (0410) 035-21389-001
More informationTG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B)
www.source1parts.com HVAC SERVICE PARTS 23 TG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B) Supersedes: 035-23623-001 Rev. H (1115) 035-23623-001 Rev. J (1117) 26 1 of 6 44
More informationPC9 SERIES MODULATING VARIABLE SPEED CONDENSING DOWNFLOW/HORIZONTAL NATURAL GAS FURNACES - (STYLE A)
www.source1parts.com HVAC SERVICE PARTS PC9 SERIES MODULATING VARIABLE SPEED CONDENSING DOWNFLOW/HORIZONTAL NATURAL GAS FURNACES - (STYLE A) Supersedes: 035-214-001 Rev. B (0706) 035-214-001 Rev. C (1006)
More informationFC9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen, Style D and 2nd Gen, Style B)
www.source1parts.com HVAC SERVICE PARTS FC9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen, Style D and 2nd Gen, Style B) Supersedes: Nothing, See Back 035-21322-001 Rev.
More informationGM9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen (Style D) and 2nd Gen, STYLE B)
www.source1parts.com HVAC SERVICE PARTS GM9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen (Style D) and 2nd Gen, STYLE B) Supersedes: 035-21326-001 Rev. A (0207) 035-21326-001
More informationAHP SERIES SINGLE PIECE AIR HANDLER R-22 TXV AND FLEX COIL MODELS (STYLE A&B)
www.source1parts.com AHP SERIES SINGLE PIECE AIR HANDLER R-22 TXV AND FLEX COIL MODELS (STYLE A&B) HVAC SERVICE PARTS Supersedes:03-21126-001 Rev. E (0408) 03-21126-001 Rev. F (0609) 1 of 8 12 4 3 6 7
More informationDDYZ SERIES - 13 SEER SINGLE PACKAGED GAS/ELECTRIC AIR CONDITIONER (R-410A, STYLE A,B)
www.source1parts.com HVAC SERVICE PARTS DDYZ SERIES - 13 SEER SINGLE PACKAGED GAS/ELECTRIC AIR CONDITIONER (R-410A, STYLE A,B) Supersedes:035-23383-001 Rev. A (1211) 035-23383-001 Rev. B (0112) 1 of 14
More informationPAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A)
www.source1parts.com HVAC SERVICE PARTS PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A) Supersedes:035-21137-001 Rev. E (1107) 035-21137-001 Rev. F (0611) 1 of 8 CONDENSER ROOF (SEE
More informationTECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES
036-1354-001 Rev. D (110) Heating TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE NATURAL GAS 37-111 MBH OUTPUT Air Conditioning EFFICIENCY RATING
More informationTECHNICAL GUIDE. AFFINITY MODELS: PS8*DH GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW/HORIZONTAL FURNACES STANDARD & Low NOx DESCRIPTION WARRANTY
TEHNIAL UIDE AFFINIT MODELS: PS8*DH AS-FIED HIH EFFIIEN SINLE STAE DONFLO/HOIZONTAL FUNAES STANDAD & Low NOx NATUAL AS 40-130 MBH INPUT EFFIIEN ATIN ETIFIED DESIPTION These high efficiency, downflow/horizontal
More informationGME8. Two-Stage Convertible, Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h
Two-Stage onvertible, Multi-Speed EM Gas Furnace 80% AFUE Heating Input: 60,000 100,000 BTU/h ontents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow Data... 5 Wiring Diagrams...
More informationRP8.1Y (ERRATA 1) (202) 2 of 8
530.18-RP8.1Y (ERRATA 1) (202) 2 of 8 ELECTRICAL (Cont.) FIG ITEM DESCRIPTION D6CG048N06006A D6CG048N06025A D6CG048N06046A D6CG048N06058A 3-BURNER 3-BURNER 3-BURNER 3-BURNER * 15 CONNECTOR, CAP (9-CIRCUIT)
More informationComfortNet -Compatible
GMV8 omfortnet -ompatible Two-Stage, Variable-Speed Gas Furnace 80% AFUE Heating Input: 60,000 00,000 BTU/h Standard Features Aluminized steel, dual-diameter tubular heat exchanger Two-stage gas valve
More informationTECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: F6FP DESCRIPTION FEATURES UTG-B-0409
TEHNIAL UIDE SINLE PIEE AIR HANDLERS FOR USE WITH SPLIT-SSTEM OOLIN & HEAT PUMPS MODELS: F6FP018-060 DESRIPTION This fan coil unit provides the flexibility for installation in any upflow or horizontal
More informationUSER S INFORMATION, MAINTENANCE AND SERVICE MANUAL
USER S INFORMATI, MAINTENANCE AND SERVICE MANUAL HIGH EFFICIENCY TUBULAR HEAT EXCHANGER SERIES MODELS: GY8S / GM8S / LY8S / LM8S / LF8 (Single Stage Upflow / Horizontal / LoNOx) EFFICIENCY RATING CERTIFIED
More informationTECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.
036-1349-001 Rev. A (30) Heating TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 9 AFUE NATURAL GAS 37-130 MBH OUTPUT Air Conditioning EFFICIENCY RATING CERTIFIED R
More informationLRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS
Service Literature orp. 1501-L2 August 2016 Revised March 2017 LRP14HP/DF/A/GE LRP16GE/HP 2 to 5 Ton (7.0 to 17.6 kw) LRP14HP/LRP14DF/LRP14A/LRP14GE/LRP16GE/LRP16HP SERIES UNITS The LRP14/16 series packaged
More informationTECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C)
TEHNIAL UIDE SINLE PIEE VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT-SYSTEM OOLIN & HEAT PUMPS MODELS: AV24 THRU 60*() DESRIPTION The Air Handler line offers the ultimate in comfort, sound and application
More informationGUH & GDD SERIES REPLACEMENT PARTS LIST SINGLE STAGE CONDENSING & NON-CONDENSING FURNACES 80+ AFUE 92.1% AFUE 95.0 % AFUE. GUH92A Upflow / Horizontal
REPLACEMENT PARTS LIST GUH & GDD SERIES SINGLE STAGE CONDENSING & NON-CONDENSING FURNACES NON-CONDENSING GAS FURNACES CONDENSING GAS FURNACES 80+ AFUE 92.1% AFUE 95.0 % AFUE GUH80A Upflow / Horizontal
More informationTECHNICAL GUIDE MODELS: GY9F*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 95% AFUE DESCRIPTION WARRANTY FEATURES YTG-B-0907
TEHNIAL UIDE MODELS: 9F*UP AS-FIED ONDENSIN / HIH EFFIIEN UPFLO FUNAES 95% AFUE NATUAL AS 48-96 MBH INPUT EFFIIEN ATIN ETIFIED ISO 9001 ertified Quality Management System DESIPTION These ategory IV, highly
More informationInstallation Instructions
Installation Instructions Twinning Kit For HSI Single- and -Speed Upflow Non-ondensing and Single-Speed ondensing Gas Furnaces KGATW040HSI NOTE: Read the entire instruction manual before starting the installation.
More informationTECHNICAL GUIDE MODELS: GM9S*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW/HORIZONTAL FURNACES 92% TO 94% AFUE DESCRIPTION WARRANTY FEATURES
TEHNIAL UIDE MODELS: M9S*DH AS-FIED ONDENSIN / HIH EFFIIEN DONFLO/HOIZONTAL FUNAES 92% TO 94% AFUE NATUAL AS 40-120 MBH INPUT EFFIIEN ATIN ETIFIED ISO 9001 ertified Quality Management System 278177-BT-A-0407
More informationUSER S INFORMATION, MAINTENANCE AND SERVICE MANUAL
USER S INFORMATION, MAINTENANCE AND SERVICE MANUAL MODELS: G8C/ GF8 (Single Stage Multi-Position) EFFICIENCY RATING CERTIFIED ISO 9001 Certified Quality Management System CONTACT INFORMATION...............................
More informationTECHNICAL GUIDE MODELS: GM9S*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92% TO 94% AFUE DESCRIPTION WARRANTY FEATURES BTG-A-0407
TEHNIAL UIDE MODELS: M9S*UP AS-FIED ONDENSIN / HIH EFFIIEN UPFLO FUNAES 92% TO 94% AFUE NATUAL AS 40-135 MBH INPUT EFFIIEN ATIN ETIFIED ISO 9001 ertified Quality Management System DESIPTION These ategory
More informationKG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS KG6TE Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 95.1 Upflow/Horizontal The high effi ciency 2-Stage gas furnace
More informationTECHNICAL MANUAL. GMH95 40" 95% Gas Furnace
TEHNIAL MANUAL AL 40" 95% Gas Furnace Refer to Service Manual RS660004 for installation, operation, and troubleshooting information. All safety information must be followed as provided in the Service Manual.
More informationGMH95/GCH9 MULTI-POSITION, DUAL$AVER CONVERTIBLE, MULTI-SPEED GAS FURNACE
95%/93% AFUE HEATING INPUT: 46,000 5,000 BTU/H Standard Features / MULTI-POSITION, DUAL$AVER ONVERTIBLE, MULTI-SPEED GAS FURNAE The Goodman / 95%/93% AFUE Dual$aver onvertible, Multi-Speed, Multi-Position
More informationGCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h
(B) Heating Input: 0,000 0,000 BTU/h Two-Stage, Variable-Speed EM Gas Furnace Up to 9% AFUE ontents Nomenclature... Accessories... Product Specifications... Dimensions... flow Specifications...5 Wiring
More informationEnergy Saver Commercial Gas Millivolt (DM) Models
COMMERCIAL REPLACEMENT PARTS LIST Energy Saver Commercial Gas Millivolt (DM) Models Includes Hydrojet Total Performance System Effective: May, 2011 ECO 7428 NOTE: BOTH MODEL AND SERIAL NUMBERS ARE REQUIRED
More informationTECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS
DESRIPTION This fan coil unit provides the flexibility for installation in any upflow or horizontal application. These versatile models may be used for split-system cooling or heat pump operation. ompact
More informationMERIT SERIES Downflow
PRODUCT SPECIFICATIONS GAS FURNACES ML80DF MERIT SERIES Downflow Bulletin No. 20643 February 208 Supersedes November 207 AFUE - 80% Input - 44,000 to 0,000 Btuh Nominal Add-on Cooling -.5 to 5 Tons MODEL
More informationGCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h
(B) Heating Input: 0,000 0,000 BTU/h Two-Stage, Variable-Speed EM Gas Furnace Up to 9% AFUE ontents Nomenclature... Accessories... Product Specifications... Dimensions... flow Specifications...5 Wiring
More informationTECHNICAL SPECIFICATIONS
TM TECHNICAL SPECIFICATIONS Model PGF1TE 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 95.1 AFUE Direct Vent or Non Direct Vent Condensing Furnace 10 YEAR WARRANTY WORRY-FREE PERFORMANCE
More informationMASTERTEMP HEATER REPLACEMENT PARTS
0 Section. Maintenance/Replacement Parts Electrical System (Key Nos. through 4), See Page 2 Burner System (Key Nos. through ), See Page 4 Water System (Key Nos. through ), see Page 2 Repair Parts are available
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS
ACCESSORY KIT INSTALLATION INSTRUCTIONS Masonry Chimney Draft Hood Kit GENERAL INFORMATION DESCRIPTION Tile Lined Chimney Kit Model Numbers CK060 and CK0604 permits the venting of an 80% induced draft
More informationTECHNICAL GUIDE AFFINITY MODELS: PS9*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% TO 94% AFUE
TEHNIAL UIDE AFFINIT MODELS: PS9*UP AS-FIED ONDENSIN / HIH EFFIIEN UPFLO SINLE STAE FUNAES 92% TO 94% AFUE NATUAL AS 40-135 MBH INPUT EFFIIEN ATIN ETIFIED ISO 9001 ertified Quality Management System Due
More informationUSER S INFORMATION, MAINTENANCE AND SERVICE MANUAL
USER S INFORMATI, MAINTENANCE AND SERVICE MANUAL HIGH EFFICIENCY TUBULAR HEAT EXCHANGER SERIES MODELS: P*XU/ G9D-UP Two Stage (Upflow) EFFICIENCY RATING CERTIFIED This product was manufactured in a plant
More informationFG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS FG6T(C,L) Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 92+ Upflow/Horizontal 90+ Downflow The high effi ciency 2-Stage
More informationINSTALLATION MANUAL TWO STAGE VARIABLE SPEED ECM RESIDENTIAL GAS FURNACES. MODELS: TM9V Series (96% AFUE Multi-position) LIST OF SECTIONS
INSTALLATION MANUAL TWO STAGE VARIABLE SPEED EM RESIDENTIAL GAS FURNAES MODELS: TM9V Series (96% AFUE Multi-position) SAFETY........................................... 2 DUTWORK........................................
More information90TJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to kw] (All Models 90% A.F.U.E. or Above)
FORM NO. G66-480 Supersedes Form No. G66-480 Rev. 0 90TJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) 90 EFFICIENCY DOWNF/ HORIZONTAL
More informationTECHNICAL GUIDE MODELS: GM9T-UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW TWO STAGE FURNACES UP TO 94% AFUE
TEHNIAL UIDE MODELS: M9T-UP AS-FIED ONDENSIN / HIH EFFIIENY UPFLOW TWO STAE FUNAES UP TO 94% AFUE NATUAL AS 40-120 MBH INPUT EFFIIENY ATIN ETIFIED ISO 9001 ertified Quality Management System Due to continuous
More informationInstallation Instructions
KSALA0201R22 KSALA0301410 Low--Ambient Pressure Switch Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY ONSIDERATIONS Improper installation, adjustment,
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model PGF1TA 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 80+ Upflow/Horizontal 2 Stage Gas Furnace with Variable Speed Blower 2 10 YEAR WARRANTY WORRY-FREE
More informationREPAIR PARTS. GCVC 80% 2-Stage Variable Speed Downflow Horizontal Furnace. This manual is to be used by qualified technicians only.
REPAIR PARTS GCVC 80% 2-Stage Variable Speed Downflow Horizontal Furnace GCVC80603BXBC GCVC80803BXBC GCVC80805CXBC GCVC81005CXBC This manual is to be used by qualified technicians only. 2016 Goodman Manufacturing
More informationParts List for Ener-Radiant XL Tube Heaters
Parts List for Ener-Radiant XL Tube Heaters ERXL-0 F09XL ERXL-0 NG / BRN & Cont Box 0 Front Flange F09XL ERXL-0 LP / BRN & Cont Box 009 Reflector End Cap F00XL Tube Set- 0' 099 Spring Clips 0 Tube H.E.
More informationINSTALLATION INSTRUCTIONS Low Ambient Kit NASA201LA, NASA401LA
INSTALLATION INSTRUTIONS Low Ambient Kit NASA201LA, NASA401LA These instructions must be read and understood completely before attempting installation. DANGER, WARNING, AUTION, and NOTE The signal words
More informationTECHNICAL MANUAL. ADVC8/AMVC8 GMVC8 80% Gas Furnace Units
TEHNIAL MANUAL AL TM ADV8/AMV8 GMV8 80% Gas Furnace Units Refer to Service Manual RS660004 for installation, operation, and troubleshooting information. All safety information must be followed as provided
More informationThrough-The-Wall (TTW2) Energy Saver Models
RESIDENTIAL GAS REPLACEMENT PARTS LIST Through-The-Wall (TTW2) Energy Saver Models Includes Hydrojet Total Performance System Dash Twelve (-12) Models Effective: November 1, 2001 NOTE: BOTH MODEL AND SERIAL
More informationGMVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h
(B) Heating Input: 0,000 0,000 BTU/h Two-Stage, Variable-Speed EM Gas Furnace Up to 9% AFUE ontents Nomenclature... Accessories... Product Specifications... Dimensions... flow Data... Wiring Diagrams...
More information27" Gas Dryer MODELS: MGDB950YW3 (White) MGDB950YG3 (Cosmetallic) 05/31/ Maytag Part No. W Rev. A
27" Gas Dryer MODELS: MGDB950YW3 (White) MGDB950YG3 (Cosmetallic) 05/31/2013 2013 Maytag Part W10617393 Rev. A TOP AND CONSOLE PARTS 05/31/2013 2 Part W10617393 Rev. A TOP AND CONSOLE PARTS Part Description
More information90 HIGH EFFICIENCY UPFLOW GAS FURNACES
FORM NO. G66-477 Supersedes Form No. A11-152 Rev. 3 90 EFFICIENCY UPF GAS FURNACES 90RJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above)
More informationProduct Data. S UTEC ignition control and fan timer board provide. S S Cabinet features an insulated enclosure for the burner
LOW --- BOY OIL FURNAE INPUT RATE: 70,000 thru 154,000 BTUH ERIE 10 Product Data THE LATET IN OIL FURNAE TEHNOLOGY A0666 The model combines high efficiency and quiet operation with oil heating technology.
More informationWiring Diagram Owner's Guide Installation Instructions Service Data Sheet Timer Guide
Product No. Series 30" gas Color black Market North America Wiring Diagram 318550110 Owner's Guide 318203872 Installation Instructions 318201673 Service Data Sheet 318127060 Timer Guide 318200184 FGS365EC.eps
More informationnufacturing Company, L.P San Felipe, Suite 500
REPAIR PARTS GMPN Multi-Positional Gas Furnace GMPN040-3 GMPN060-3 GMPN080-4 GMPN100-4 GMPN120-5 nufacturing Company, L.P. San Felipe, Suite 500 www.amana-hac.com www.amana-hac.com This manual is to be
More informationThis parts list is current as of the above revision date. See for the current revision.
- Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800--.pdf for the current revision. Package Air onditioners Table of ontents Model Explanation...................................................................................................................
More informationRheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace
Gas Furnaces Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace R802V Downflow Series 80% A.F.U.E. Input Rates 75-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated
More informationUSER S INFORMATION, MAINTENANCE AND SERVICE MANUAL
USER S INFORMATI, MAINTENANCE AND SERVICE MANUAL HIGH EFFICIENCY TUBULAR HEAT EXCHANGER SERIES MODELS: PV8*DH/FL8V*DH/FC8V*DH/LL8V*DH/LC8V*DH (Variable Speed Downflow/Horizontal/Low NOx) EFFICIENCY RATING
More informationGAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES
FORM NO. G66-452 REV. 3 Supersedes Form No. G66-452 Rev. 2 GAS FURNACES WGTA- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (U.S. & Canadian Models) (All Models 90% A.F.U.E.
More information80% A.F.U.E. DOWNFLOW GAS FURNACES
FORM NO. G11-496 REV. 4 Supersedes Form No. G11-496 Rev. 3 RGLS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) 80% A.F.U.E. DOWNF GAS FURNACES The
More informationTECHNICAL GUIDE. Echelon MODELS: FC9T GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW TWO STAGE FURNACES UP TO 94% AFUE
TEHNIAL UIDE Echelon MODELS: F9T AS-FIED ONDENSIN / HIH EFFIIENY UPFLOW TWO STAE FUNAES UP TO 94% AFUE NATUAL AS 40-120 MBH INPUT EFFIIENY ATIN ETIFIED Due to continuous product improvement, specifications
More informationGAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES
FORM NO. G11-452 REV. 10 Supersedes Form No. G11-452 Rev. 9 GAS FURNACES RGTA- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) CLASSIC
More informationGAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR
FORM NO. G22-506 Supersedes Form No. G22-506 Rev. 1 GAS FURNACES RGLT- SERIES Models with Input Rates from 75,000 to 125,000 BTU/HR [22 to 37 kw] (U.S. & Canadian Models) Annual Fuel Utilization Efficiency
More informationUSER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY...................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS.......................... 2 INTERMITTENT IGNITION DEVICE..........
More informationEffective october 14, 2014
COS-20G combi oven-steamer REPLACEMENT PARTS LIST Effective october 14, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified
More informationELITE SERIES Downflow - High Efficiency Blower Motor
PRODUCT SPECIFICATIONS GAS FURNACES EL80DFE ELITE SERIES Downflow - High Efficiency Blower Motor Bulletin No. 2066 July 208 Supersedes February 208 AFUE - 80% Input - 44,000 to 0,000 Btuh Nominal Add-on
More informationMP GS/GD 10 GAS. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)
MP GS/GD 0 GAS Toll Free Phone, (US & Canada): (800) 427-6668 Toll Free Fax, (US & Canada): (800) 36-7745 http://www.garland-group.com FORM # Moisture Plus Gas GS/GD0 (Rev 5) Page 2 FORM # Moisture Plus
More informationReplacement Parts List
Replacement Parts List SINGLE PACKAGE AIR CONDITIONER GENERATION 4 42 CABINET Note: This is a non-comprehensive parts list intended for stocking purposes for first production (style A) units based on current
More informationREPLACEMENT PARTS LIST
REPLACEMENT PARTS LIST PACKAGED GAS HEATING/ELECTRIC COOLING R7TQ SERIES 6-, 7.5-, AND 10-TON, 81% STEADY STATE EFFICIENCY IMPORTANT This document is primarily intended to assist qualified individuals
More informationTechnical Manual MAY 2008 Edition
SPECIFICATION - GMP SERIES MULTI POSITION INDUCED DRAFT GAS FURNACE EARLY MODELS WITH HOT SURFACE IGNITION AND LATER MODELS WITH DIRECT SPARK IGNITION A.G.A. Approval No. 5113 Technical Manual MAY 2008
More informationGAS DRYER MODELS: MGD8200FW0 (White) MGD8200FC0 (Chrome Shadow) 05/24/ Maytag Part No. W Rev. A
GAS DRYER MODELS: MGD8200FW0 (White) MGD8200FC0 (Chrome Shadow) 05/24/2016 2016 Maytag Part W10884161 Rev. A TOP AND CONSOLE PARTS 05/24/2016 2 Part W10884161 Rev. A TOP AND CONSOLE PARTS Part Description
More informationFigure 10 or Figure 6
SUPPLEMENT TO INSTRUCTION MANUAL P/N 238-45637-00 and 238-48933-00 (Replaces pg. 32 (238-45637-00) or pg. 28 (238-48933-00) in Wiring Diagram Honeywell A B C VERY HO HO LOW Figure 10 or Figure 6 238-48214-00B
More informationAMVM97 (B) / ACVM97 (B)
(B) / (B) Heating Input: 60,000 0,000 BTU/h Modulating, Variable-Speed EM Gas Furnace Up to 98% AFUE ontents Nomenclature... Product Specifications... Dimensions... 4 flow Specifications... 6 Wiring Diagram...
More informationTechnical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)
Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper
More informationThrough-The-Wall (TTW1) Energy Saver (MI) Models
RESIDENTIAL GAS REPLACEMENT PARTS LIST Through-The-Wall (TTW1) Energy Saver (MI) Models Includes Hydrojet Total Performance System Dash Twelve, Thirteen (-12, -13) Models Effective: May 12, 2003 ECO 6751
More informationProduct Data. 58RAV High-Efficiency Downflow/Horizontal Induced-Combustion Gas Furnace. 80% AFUE At Budget Price
Product Data 58RAV High-Efficiency Downflow/Horizontal Induced-ombustion Gas Furnace Input apacities: 50,000 thru 5,000 Btuh 80% AFUE At Budget Price DOWNFLOW HORIZONTAL arrier provides an 80% Annual Fuel
More informationZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING
See unit nameplate for manufacturer and address. 507258-04 7/2018 Supersedes 10/2017 ZG 036, 048, 060, 072, 074 (3, 4, 5 and 6 Tons) ZG 092, 102, 120, 150 (7-1/2, 8-1/2, 10 and 12 Tons) ROOFTOP UNITS ZG
More informationURGPV & ULGPV ECO MODELS
RESIDENTIAL GAS REPLACEMENT PARTS LIST URGPV & ULGPV ECO MODELS Includes Hydrojet Total Performance System Effective: May, 2015 ECO 7950 NOTE: BOTH MODEL AND SERIAL NUMBERS ARE REQUIRED FOR ORDERING REPLACEMENT
More information