1 Model Number: V1/300/B (ez-slide control) HIGH EFFICIENCY INSET COAL EFFECT GAS CONVECTOR FIRE INSTALLATION & USER INSTRUCTIONS GB IE SUITABLE FOR USE ON NATURAL GAS (G20) AT 20mbar SUPPLY PRESSURE These instructions must be left with the appliance for future reference and for servicing information. The customer must be made fully aware of the appliance operational procedure before leaving this booklet with them. V1/300 Rev.2 (Sep 2012) VISION FIRES

2 CONTENTS TECHNICAL INFO 3 Appliance Information 3 Efficiency Information 3 Ventilation Requirements 3 INSTALLATION REQUIREMENTS 4 General Installation Conditions 4 Flue/Chimney Suitability and Inspection 4 Preparation of the Fireplace Opening 5 Fireplace Opening Size 5 Shelf Position 5 Fireguard Requirements 5 APPLIANCE INSTALLATION 6 Unpacking the Fire 6 Gas Connection 6 Preparing the Appliance 6 Installing the Firebox 7 Fuel Bed Assembly 9 Lighting the Appliance 12 Flue Restrictor 12 Spillage Test 13 Outlet Canopy 13 Fascia 14 Review & Handover 14 SERVICING AND MAINTENANCE 14 Servicing 14 Removing the Burner Assembly 15 SPARES 15 USER GUIDE 16 General Information 16 Operating Procedure 17 Replacing the Battery 18 Ceramic Fuel Bed 18 Spillage Safety System 19 Cleaning 19 Fascia 19 2

3 TECHNICAL INFORMATION APPLIANCE INFORMATION This appliance should be used with Natural Gas (G20) only. Model: Gas Type Maximum Gross Input Minimum Gross Input Inlet Pressure Gas Connection Ignition V1/300/B G20 natural gas 5.2kW (17,750 Btu/h) 2.6kW (8,875 Btu/h) 20mbar ±1.5mbar 8mm pipe Battery Spark Burner Injector Cat Pilot Type NOx Classification 5 Seagas P432D EFFICIENCY The efficiency of this appliance has been measured as specified in BS and the result is 80.5% Gross Efficiency. The gross calorific value of the fuel has been used for this efficiency calculation. The test data from which it has been calculated has been certified by B.S.I. The efficiency value may be used in the UK Government s Standard Assessment Procedure (SAP) for the energy rating of Dwellings. VENTILATION REQUIREMENTS In the UK, purpose made ventilation is not normally required for this appliance except in new build houses. However, if spillage is detected during commissioning of the appliance, this may mean there is insufficient ventilation. Additional ventilation may then be required. Please refer to any national ventilation requirements in this instance. In the ROI, it will be necessary to refer to I.S. 813 issued by the National Standards Authority of Ireland. Any air vent must not be restricted. 3

4 INSTALLATION REQUIREMENTS GENERAL INSTALLATION CONDITIONS In the United Kingdom it is law that all gas appliances are fitted by a competent person in accordance with the most up to date edition of the Gas Safety (Installation and Use) Regulations. Failure to install the appliance correctly could lead to prosecution. The installation must also be in accordance with all relevant parts of the Local and National Building Regulations, all relevant code of practice, and all applicable requirements of the following British Standards: BS EN 1856 Part 1 BS BS EN 1858 BS EN 1806 BS EN 1856 Part 1 BS 5440 Parts 1 & 2 BS 6461 Part 1 BS 5871 Part 2 BS 6891 Chimneys - Requirements for metal chimneys. Specification for metal flue boxes or gas fired appliances not exceeding 20kW. Chimneys - Components - Concrete flue blocks. Chimneys - Clay/ceramic flue blocks. Chimneys - Requirements for metal chimneys. Installation of Flues and Ventilation. Masonry chimneys & flues - Installation. Installation - Inset LFE gas fires. Gas pipework installation. FLUE/CHIMNEY SUITABILITY AND INSPECTION This appliance is for use with 225mm x 225mm conventional brick built chimneys and fabricated flues. Any chairbrick must be removed If the chimney has previously been used for solid fuel, the chimney must be swept before installation of the appliance. Minimum size of all flues: 125mm diameter or equivalent area. On 125mm diameter and precast flues the restrictor must be not be fitted. Minimum effective height of all flue types: 3 metres. Single wall, twin wall or flexible flue liner must be stainless steel or aluminium and conform to BS EN 1856 Part 1. The flue system must conform to BS 5440 Part 1 in design and installation. The flue must not be used for any other appliance. Any dampers or register plates must be removed or locked in the open position. If a metal flue box (to BS 715) is used it must be totally insulated with a minimum of 50mm of suitable insulation. 4

5 INSTALLATION REQUIREMENTS PREPARATION OF THE FIREPLACE OPENING The appliance must be installed mounted on a non-combustible hearth. It must not be installed directly on any combustible material. The hearth must be at least 12mm thick with a periphery thickness of at least 50mm. It should be at least 700mm wide and project at least 300mm forwards from the fire opening. The appliance must be fitted into a non combustible opening. The area around the fire opening (where the appliance side and top flanges meet it) should be reasonably flat to ensure a good seal. If necessary, take appropriate measures to ensure this. The floor within the fireplace opening should be reasonably flat to ensure a good seal can be made at the bottom of the appliance. Any underfloor air supply to the fire opening must be sealed off completely. The appliance can be fitted with a non combustible fireplace surround or a proprietary fireplace surround with a temperature rating of at least 150 C. FIREPLACE OPENING SIZE When preparing the opening, please observe the following dimensions are met: WIDTH HEIGHT DEPTH MINIMUM OPENING SIZE 405mm 555mm 265mm MAXIMUM OPENING SIZE 457mm 575mm - SHELF POSITION The appliance can be installed below a combustible shelf as long as there is a minimum distance of 750mm from the top of the hearth and the shelf does not project more than 150mm. If the shelf projects more than 150mm then the distance between the top of the hearth and the shelf needs to increase by 15mm for every additional 25mm of projection beyond 150mm. FIREGUARD REQUIREMENTS A fireguard complying with BS 8423 should be fitted for the protection of children, the elderly, the infirm and pets. 5

6 APPLIANCE INSTALLATION UNPACKING THE FIRE Carefully remove the appliance from the carton, taking special care with any ceramic components. Remove all loose item packaging and check for all components which should include: 1 x Firebox with burner assembly 1 x Box containing ceramic components. 1 x Installation and User Instruction manual 1 x Loose parts pack including: 1 x Strip of floor sealing tape 1 x Inlet T connector 1 x Nut & olive for 8mm inlet pipe. 1 x Grommet for rear of firebox 4 x Woodscrews 6 x Fibre/wooden plugs 4 x Eyebolts 2 x Tension cables 2 x Cable adjusters 1 x Foam Seal 2 x Fascia fixing screws 1 x Outlet canopy 1 x Battery 1 x Restrictor plate 1 x Battery (ez-slide model only) GAS CONNECTION A concealed gas connection is recommended. If concealed pipework is required then steps must be taken to extend the supply line so that it enters the firebox through the supply hole at the bottom right hand side. The pipe should run through the supply hole and to the inlet T connector towards the front of the fire. Please ensure that the supply pipework does not encroach on the space required to fit the firebox into the fire opening. The inlet T connector features a valve for isolating the gas supply and a pressure test point. After installation, connect a suitable pressure test gauge to the pressure test point on the inlet T. With the fire lit check that the supply pressure is 20 ±1.5mbar. Disconnect the pressure gauge and check for gas soundness. PREPARING THE APPLIANCE The glass must be removed to gain access to place ceramic components and to remove the burner unit to prepare gas supply connection. To remove the burner unit, follow the steps on the following page. 6

7 APPLIANCE INSTALLATION PREPARING THE APPLIANCE Disconnect the control linkage by removing the screw indicated by 1 in Fig. 1. Remove the 6 screws indicated by 2 in Fig. 1. Remove the 3 screws indicated by 3 in Fig. 1. Holding the glass firmly in place remove the top and side glass retainers, then carefully lift the glass away and place in a safe area. Remove the 2 screws indicated by 5 in Fig. 2 and then carefully lift the burner from the firebox. Fig. 1 Fit the foam seal to the rear of the firebox side and top flanges. Carefully measure and cut each piece ensuring that it is not overstretched and that there are no gaps where each piece of foam meet. A complete seal must be achieved around the three flanges. INSTALLING THE FIREBOX There are two options of fixing the firebox into the fire opening/fireplace surround. Fig. 2 Option 1 - Front Fixing Offer the firebox into the opening ensuring that the supply pipe is correctly positioned. When the firebox is in the intended position of installation make a mark through the holes indicated on Fig. 3. Carefully remove the firebox and drill and plug the fireplace where previously marked using a correctly sized masonry bit and the fibre plugs supplied. Re-position the firebox into the fireplace and secure using 4 woodscrews, tightening to seal the firebox to the fireplace. Fig. 3 7

8 APPLIANCE INSTALLATION INSTALLING THE FIREBOX Option 2 - Cable Fixing Using Fig. 4, mark out the four positions indicated on the back of the fire opening. Drill each mark using a suitable masonry bit and fit the fibre plugs supplied. Securely screw the eye bolts into the plugs Position the firebox in front of the fire opening, allowing enough space behind the appliance for access to the fire opening and fitting of the cables. At this stage, if a concealed gas connection is required, feed the supply pipe through the hole at the bottom at the rear of the firebox. Locate the holes to the sides of the convection channel and fit the cables as shown in Fig. 5. Give the cables a sharp pull so that they grip the firebox. Thread the cables through the top eye bolts, then the bottom eyebolts, and then feed them into the holes at the bottom of the back face of the fire box (see Fig. 6). Fig. 4 Fig. 5 Reposition the firebox into the opening and push against the fireplace ensuring a seal against the foam strips on the rear of the firebox flanges. Fit a cable retainer over each cable and, pulling the cables taught, push the retainers into the holes that the cables run through. Tighten the screws in the cable retainers so that they clamp onto the cables. Hand turn the adjustment screws on the retainers to apply tension to the cables. Do not over tighten the cables. Check that there are no gaps around the foam strips. Using the sealing tape supplied, create a seal between the bottom face of the firebox and the fireplace floor. Reposition the burner and secure with the two screws previously removed. Connect the supply line to the appliance. Turn on the gas supply and pressure test the pipework installation for soundness according to current standards. Fig. 6 7

9 APPLIANCE INSTALLATION FUEL BED ASSEMBLY Take the ceramic coal matrix and place it on top of the ceramic burner (factory-clamped to the burner tray), ensuring that it is pushed to the back of the hot box (see Fig. 7) Next take the onepiece ceramic coal front and gently place it in front of the ceramic burner (see Fig. 8). Fig. 7 Fig. 8 Next, carefully unpack each of the individual coals and familiarise yourself with their appearance before proceeding to coal placement. There are : 4 x A 2 x B 2 x C 2 x D 2 x E 2 x F 2 x G 8

10 APPLIANCE INSTALLATION Ensuring that neither coals are touching each other, take the five coals as indicated in Fig. 9 below, and position them using the five notches in the one-piece front coal as locators. Fig. 7 Fig. 9 Next, take the four coals indicated and position as shown in Fig. 10 below. Fig. 10 9

11 APPLIANCE INSTALLATION Next, take the two coals indicated and position as shown in Fig. 11 below. Fig. 11 Next, take the five coals indicated and position as shown in Fig. 12 below. Fig. 12 Only use the coals that are supplied with this appliance. If replacement coals are required, use only a full genuine replacement set. Reconnect the slider arm to the gas control pivot. Refit the glass and the glass retainers by reversing the steps taken to remove it earlier (see page 7 for details). Fit the supplied battery. 10

12 APPLIANCE INSTALLATION LIGHTING THE APPLIANCE Open the gas isolation valve. Push the control lever fully down to the P position and hold there until the pilot lights. Hold for a further 10 seconds to allow a stable flame. Release the control lever and it will automatically raise to the LO position. The fire is now at minimum heat setting. Lift the control lever up to the HI position. You will feel a positive location check when the lever reaches this setting. Lift the control lever fully up to the O position to extinguish the pilot and main burner. The appliance is now turned off. FLUE RESTRICTOR The appliance is supplied with a front fixing flue restrictor. Generally the restrictor is not required but if the flue is found to be pulling excessively then it can be fitted by holding the restrictor by the long tab and inserting it into the top vent of the convection outlet. With your other hand, use a long screwdriver and screw the restrictor to the rear of the firebox. See Fig. 13. Fig

13 APPLIANCE INSTALLATION SPILLAGE TEST 1 Close all of the doors and window in the room of the appliance. 2 Ignite the appliance and set to HI position. 3 After 5 minutes hold a smoke match inside the fire. This should be positioned approximately 20mm inside the top opening at a distance of approximately 75mm from the side (see Fig. 14). In a successful installation all of the smoke should be drawn directly into the flue. If in doubt, wait a further 10 minutes and repeat the test. 4 If spillage still occurs and the flue restrictor is fitted then wait for the fire to cool, remove it and perform the spillage test again. 5 If spillage still occurs then there may be a problem with the flue. Disconnect the appliance and seek expert advice. 6 If the spillage test is successful then open all internal doors in the room. Keep all external doors and windows closed. Re-test again for spillage as instructed above. If there s an extractor fan in the vicinity of the appliance then test again with the extractor fan turned on and all interconnecting doors open. Fig. 14 OUTLET CANOPY Fit the outlet canopy the appliance using the three tapping screws provided (see Fig. 15) Fig

14 APPLIANCE INSTALLATION / SERVICING & MAINTENANCE FASCIA This appliance can be used with several different Vision Fires fireframes or frets. For full instructions on how to fit them please refer to the guide that is supplied with them. It is important that the adhesive control sticker (supplied with this fire) is fitted to the fascia as per instruction in the fascia fitting guide. REVIEW & HANDOVER Inspect the appliance and make any last minute adjustments to the ceramic positioning if required. Hand the instruction manual over to the customer and fully explain the operating procedure of the appliance. Advise the customer that they should read the User section of the manual fully before operating the appliance. Advise that there may be a slight odour during initial use and that this is normal. Inform the customer about the importance of servicing the appliance and that this should be performed by a competent person at least once a year. Point out the Warning Label to the user and ask them to read it and then remove it from the fire. SERVICING Servicing should be carried out a least once a year by a competent person. Failure to do so will void the appliance warranty. Ensure that the fire is turned off and it is cool. The service should include a visual inspection of the chimney and fire opening for any debris. All ceramic components should be inspected and if necessary, should be replaced with a genuine full set. Check that the slots in the ceramic burner are free from soot and debris. Check that the electrode spark, pilot slot and air hole are free from soot and debris. Ensure that all ceramics components are correctly replaced as per the method in this manual. After servicing, always perform test for gas soundness and spillage. 14

15 SPARES REMOVING THE BURNER ASSEMBLY Remove the fascia from the fire. For full instructions on how to do this, consult the manual that came with the fascia. Close the isolating valve in the inlet T connector and disconnect the burner. Disconnect the control linkage and remove the glass panel (see page 7 for details) Carefully remove the individual coals, followed by the ceramic matrix and then finally the onepiece ceramic front coals. Remove the two screws fixing the burner tray to the firebox (see page 7 for details). Gently pull out the burner tray (including the ceramic burner). SPARES Below you will find a list of all of the spares you may require for future service and maintenance purposes. ITEM Ceramic Coals (loose) Complete Set Ceramic Front Coal (one piece) Ceramic Matrix Ceramic Burner Brick Set Pilot Assembly Ezi-slide Slider Mechanism CODE VLS300-GL003-01B VLS300-GL003-01A VLS100-GL002-11B VLS100-GL002-11A VLS300-GL003-01C VLS100-P4-32D VLS100-GL-QK000 15

16 USER GUIDE IF YOU SMELL GAS Turn off gas supply immediately. Extinguish all flames. Do not smoke. Do not operate any electrical switches (on or off). Open doors and windows to ventilate the area. Call the Gas Emergency Service - consult your local telephone directory for information. GENERAL INFORMATION In the United Kingdom it is law that all gas appliances are fitted by a competent person in accordance with the most up to date edition of the Gas Safety (Installation and Use) Regulations. Failure to install the appliance correctly could lead to prosecution. The installation must also be in accordance with all relevant parts of the Local and National Building Regulations, all relevant code of practice, and all applicable requirements of the following British Standards. The appliance serial number can be located on the data badge which is positioned under the coal tray. If the chimney was used for solid fuel prior to installation of this appliance then it should be swept. A fireguard complying with BS 8423 should be fitted for the protection of children, the elderly, the infirm and pets. The convection air comes out of the fire underneath the canopy. The canopy therefore gets very hot and should be treated as a working surface. The appliance can be installed below a combustible shelf as long as there is a minimum distance of 750mm from the top of the hearth and the shelf does not project more than 150mm. If the shelf projects more than 150mm then the distance between the top of the hearth and the shelf needs to increase by 15mm for every additional 25mm of projection beyond 150mm. In the UK, purpose made ventilation is not normally required for this appliance except in new build houses. However, if spillage is detected during commissioning of the appliance, this may mean there is insufficient ventilation. Additional ventilation may then be required. In the ROI, it will be necessary to refer to I.S. 813 issued by the National Standards Authority of Ireland. 16

17 USER GUIDE Any air vent must not be restricted. If the appliance is fitted to a wall without a fire surround then any wall covering must be non combustible. Soft wall coverings such as wallpaper, blown vinyl are easily affected by heat and shouldn't be used unless a fire surround is fitted. Do not add extra ceramic pieces to the appliance as this can result in incorrect combustion. If any of the ceramic components become damaged then the complete ceramic set must be replaced with genuine manufacturer s parts. Do not burn paper or other materials on the appliance. Do not use the appliance if the glass is cracked, broken or missing. Ensure that furniture and other combustible items are kept well clear of the fire. Never use aerosols or other flammable products near the fire when its in use. Always allow sufficient time after use for the fire to cool before cleaning. Servicing should be carried out a least once a year by a competent person. Failure to do so will void the appliance warranty. Please read the Servicing & Maintenance section of this manual for further information. If after installation, any home improvements are carried out such as installation of double glazing or extractor fans in adjoining rooms, etc. then a further spillage test should be carried out by a competent person. 17

18 USER GUIDE OPERATING PROCEDURE The control lever is located to the top right hand side of the fire/fascia. Push the control lever fully down to the P position and hold there until the pilot lights. Hold for a further 10 seconds to allow a stable flame. Release the control lever and it will automatically raise to the LO position. The fire is now at minimum heat setting. Lift the control lever up to the HI position. You will feel a positive location check when the lever reaches this setting. The fire is now at the maximum heat setting. The lever can be moved between the low and high positions to achieve your desired heat setting. Lift the control lever fully up to the O position to extinguish the pilot and main burner. The appliance is now turned off. It is recommended that for optimum efficiency the flue is primed for 20 minutes of operation. This can be achieved by running the appliance in its high (maximum heat) setting. If, for any reason, the fire extinguishes or is turned off then wait 3 minutes for the fire to cool before attempting to re ignite. REPLACING THE BATTERY The appliance requires one 9V PPS battery and is located behind the ash pan cover, under the fuel bed. If the battery needs replacing ensure that the + and - positions are aligned correctly. CERAMIC FUEL BED Cleaning of the ceramic coals and fuel bed is not recommended as they are fragile and my break. Light coatings of soot will be burnt off during normal operation of the fire. Do not expose any of the ceramic parts to water or cleaning agents. Damaged components must be replaced and can be ordered directly from the manufacturer. The address can be found on the rear page of this manual. If the ceramic components require replacing this should only be done by a competent person and in accordance with this manual. 18

19 USER GUIDE SPILLAGE SAFETY SYSTEM For safety, this appliance is fitted with an oxygen sensitive pilot system. This will cut off the gas supply to the appliance if the oxygen level in the room falls below its normal level. If this happens it usually indicates that there is a problem with the flue system. The fire must not be used and the problem corrected by a competent person. This device is not a substitute for an independently mounted carbon monoxide detector. CLEANING Ensure that the fire is cool before attempting any cleaning. Clean only the trims, fascia and metal parts. Do not clean the ceramic components. Use a lightly damp cloth to wipe away any dirt or marks from the metalwork. FASCIA This appliance can be used with several different Vision Fires fascia's or frets. For full instructions on how to fit them please refer to the guide that is supplied with them. Any fascia or fret to be used must conform to the following dimensions (Fig. 13). MINIMUM OPEN AREA OF FRET = 11,000mm² MINIMUM OPEN TOTAL OPEN AREA OF FRET & ASH PAN COVER COMBINED = 16,000mm² MAX HEIGHT 220MM Fig. 13 MINIMUM OPEN AREA OF ASH PAN COVER = 3,300mm² 19

20 VISION FIRES IMPERIAL POINT EXPRESS TRADING ESTATE STONE HILL ROAD FARNWORTH BOLTON BL5 9TN TEL:

(manual control) (ezi-slide control) INSET COAL EFFECT GAS CONVECTOR FIRE V1/100/B INSTALLATION & USER INSTRUCTIONS

(manual control) (ezi-slide control) INSET COAL EFFECT GAS CONVECTOR FIRE V1/100/B INSTALLATION & USER INSTRUCTIONS Model Number: V1/100/A V1/100/B (manual control) (ezi-slide control) INSET COAL EFFECT GAS CONVECTOR FIRE INSTALLATION & USER INSTRUCTIONS GB IE SUITABLE FOR USE ON NATURAL GAS (G20) AT 20mbar SUPPLY PRESSURE

More information

ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE

ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE THE NATURAL GAS MODEL IS FOR G20 AT A SUPPLY PRESSURE OF 20mbar THE PROPANE GAS MODEL IS FOR G31 AT A SUPPLY PRESSURE OF 37mbar THESE APPLIANCES

More information

INSTALLATION & USER INSTRUCTIONS

INSTALLATION & USER INSTRUCTIONS V350B REV. 03 JUN 13 Model Number: V350 B Ezi-Slide Control Gas Fire INSTALLATION & USER INSTRUCTIONS SUITABLE FOR USE ON NATURAL GAS (G20) AT 20mbar SUPPLY PRESSURE These instructions must be left with

More information

INSET LIVE FUEL EFFECT GAS FIRE

INSET LIVE FUEL EFFECT GAS FIRE 600B741/02 OWNER S GUIDE MODEL BR650 VA (GC No. 32-032-39) INSET LIVE FUEL EFFECT GAS FIRE THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) WHEN CONVERTED USING CONVERSION KIT NO.591149 THIS APPLIANCE

More information

INSTALLER GUIDE COALFLAME & LIMOUSIN. MODEL BR627 (GC No ) INSET LIVE FUEL EFFECT GAS FIRE

INSTALLER GUIDE COALFLAME & LIMOUSIN. MODEL BR627 (GC No ) INSET LIVE FUEL EFFECT GAS FIRE 600B607/05 INSTALLER GUIDE COALFLAME & LIMOUSIN MODEL BR627 (GC No. 32-032-22) INSET LIVE FUEL EFFECT GAS FIRE AS SUPPLIED, THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) WHEN CONVERTED USING VALOR CONVERSION

More information

OWNER GUIDE. Model 750. INSET LIVE FUEL EFFECT GAS FIRE Fitted with Harmony, Avignon or Style fascia. (GC No )

OWNER GUIDE. Model 750. INSET LIVE FUEL EFFECT GAS FIRE Fitted with Harmony, Avignon or Style fascia. (GC No ) 5112499/01 OWNER GUIDE Model 750 INSET LIVE FUEL EFFECT GAS FIRE Fitted with Harmony, Avignon or Style fascia (GC No. 32-032-58) THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) WHEN CONVERTED USING CONVERSION

More information

INSTALLATION & USERS INSTRUCTIONS. FOR USE WITH NATURAL GAS 20 mbar For use in GB and IE

INSTALLATION & USERS INSTRUCTIONS. FOR USE WITH NATURAL GAS 20 mbar For use in GB and IE 1 valentine s buildings Bechers drive Aintree racecourse Business Park L9 5ay CF1 L GAS APPLIANCE INSET CONVENTIONAL FLUED GAS FIRE INSTALLATION & USERS INSTRUCTIONS FOR USE WITH NATURAL GAS G20 @ 20 mbar

More information

CRYSTAL FIRES. Inset Conventional Flue Fire. (BOSTON/MIAMI) Cf1 and MANHATTAN USER INSTALLATION AND SERVICING INSTRUCTIONS

CRYSTAL FIRES. Inset Conventional Flue Fire. (BOSTON/MIAMI) Cf1 and MANHATTAN USER INSTALLATION AND SERVICING INSTRUCTIONS CRYSTAL FIRES (BOSTON/MIAMI) Cf1 and MANHATTAN Inset Conventional Flue Fire USER INSTALLATION AND SERVICING INSTRUCTIONS FOR USE WITH NATURAL GAS G20 @ 20 mbar For use in GB and IE CE THESE INSTRUCTIONS

More information

INSTALLATION & USER INSTRUCTIONS

INSTALLATION & USER INSTRUCTIONS V150B REV. 03 JUN 13 Model Number: V150 B Ezi-Slide Control Gas Fire INSTALLATION & USER INSTRUCTIONS SUITABLE FOR USE ON NATURAL GAS (G20) AT 20mbar SUPPLY PRESSURE These instructions must be left with

More information

GrateGlow THE ALL NEW CAPITAL COLLECTION. G20 at 20mbar convertible to G31 at 37mbar. For use in GB and le. Users Instructions

GrateGlow THE ALL NEW CAPITAL COLLECTION. G20 at 20mbar convertible to G31 at 37mbar. For use in GB and le. Users Instructions GrateGlow A CARVER GROUP COMPANY --..--... THE GAS CONSUMERS' COUNCIL (GCC) IS AN INDEPENDENT ORGANISATION WHICH PROTECTS THE INTEREST OF GAS USERS. IF YOU NEED ADVICE, YOU WILL FIND THE TELEPHONE NUMBER

More information

Sonnet Plus Anthem Genesis Soraya

Sonnet Plus Anthem Genesis Soraya 5110524/01 OWNER GUIDE Sonnet Plus Anthem Genesis Soraya Model 747 (GC No. 32-032-51) INSET LIVE FUEL EFFECT GAS FIRE THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) WHEN CONVERTED USING CONVERSION KIT

More information

Sonnet Plus Anthem Genesis Soraya

Sonnet Plus Anthem Genesis Soraya 5108617/01 OWNER GUIDE Sonnet Plus Anthem Genesis Soraya Model 746 (GC No. 32-032-57) INSET LIVE FUEL EFFECT GAS FIRE THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) WHEN CONVERTED USING CONVERSION KIT

More information

INSTALLATION INSTRUCTIONS COMPACT GAS STOVE MODEL NUMBER 550

INSTALLATION INSTRUCTIONS COMPACT GAS STOVE MODEL NUMBER 550 INSTALLATION INSTRUCTIONS COMPACT GAS STOVE MODEL NUMBER 550 Before installation ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the

More information

INSTALLER AND OWNER GUIDE

INSTALLER AND OWNER GUIDE 5134403/02 INSTALLER AND OWNER GUIDE Model 961 Inset live fuel effect gas fire Incorporating the control. Fitted with one of the following fascia: Aurora, Solaris or Lunar. (G.C. Number 32-032-88) For

More information

ENIGMA II SLIDE CONTROL Owner's Book

ENIGMA II SLIDE CONTROL Owner's Book ENIGMA II SLIDE CONTROL Owner's Book INCLUDES USER, INSTALLATION & MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start using the appliance Keep this booklet handy for future

More information

Kalahari DECORATIVE FUEL EFFECT GAS FIRE

Kalahari DECORATIVE FUEL EFFECT GAS FIRE Kalahari DECORATIVE FUEL EFFECT GAS FIRE User Instructions These instructions should be read by the user before operating the appliance and retained for future reference Model No. KRDC00MN & KRDC00SN are

More information

EMBERGLOW CLASSIC RADIANT CONVECTOR GAS FIRE. Installation and Maintenance Instructions

EMBERGLOW CLASSIC RADIANT CONVECTOR GAS FIRE. Installation and Maintenance Instructions , EMBERGLOW CLASSIC RADIANT CONVECTOR GAS FIRE Installation and Maintenance Instructions Hand these instructions to the user Model No. FEMC00MN is for use on Natural Gas (G20) at a supply pressure of 20

More information

Model BR660VA Heat Engine

Model BR660VA Heat Engine 5112253/01 Model BR660VA Heat Engine POWER FLUE INSET GAS FIRE (GC No. 32-032-44) THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20). WHEN CONVERTED USING CONVERSION KIT NO. 0591149 THIS APPLIANCE IS FOR

More information

Installation & Service Instructions

Installation & Service Instructions Part No. 966/9350/1 02 Potterton Housewarmer Illusion ASD - G.C. NO. 37 590 16 966 Inset DGF with ILLUSION FACIA Potterton Housewarmer Stratton ASD - G.C. NO. 37 590 17 966 Inset DGF with STRATTON FACIA

More information

Classic DECORATIVE FUEL EFFECT GAS FIRE. Installation, Maintenance & User Instructions

Classic DECORATIVE FUEL EFFECT GAS FIRE. Installation, Maintenance & User Instructions Classic DECORATIVE FUEL EFFECT GAS FIRE Installation, Maintenance & User Instructions Hand these instructions to the user Model No s CSRC**MN is only for use on Natural Gas (G20) at a supply pressure of

More information

OWNER S GUIDE ETERNITY. MODEL 540C (GC No ) INSET BALANCED FLUE GAS FIRE

OWNER S GUIDE ETERNITY. MODEL 540C (GC No ) INSET BALANCED FLUE GAS FIRE 600B637/02 ETERNITY MODEL 540C (GC No. 32-032-19) INSET BALANCED FLUE GAS FIRE THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) THIS APPLIANCE IS FOR USE IN THE UNITED KINGDOM (GB) AND THE REPUBLIC OF

More information

Model Apex Falcon, Titan & Zenit

Model Apex Falcon, Titan & Zenit Model Apex Falcon, Titan & Zenit Installation and User Instructions All instructions must be handed to user for safekeeping This is not a DIY product and must be installed by a Gas Safe registered installer

More information

COAL EFFECT BALANCED FLUE GAS FIRE

COAL EFFECT BALANCED FLUE GAS FIRE Raglan COAL EFFECT BALANCED FLUE GAS FIRE Installation and Maintenance Instructions Hand these instructions to the user Model No. KBFC**MN for use on Natural Gas (G20) at a supply pressure of 20 mbar in

More information

BLACK KNIGHT 2 - Classic Collection

BLACK KNIGHT 2 - Classic Collection BLACK KNIGHT 2 - Classic Collection Installation & Servicing Instructions (GC No. 32 170 16) IMPORTANT - THIS FIRE DOES NOT NORMALLY REQUIRE ADDITIONAL VENTILATION INTO THE ROOM IN WHICH IT IS INSTALLED

More information

PARAGON 2000 Xtra SLIDE CONTROL Owner's Book

PARAGON 2000 Xtra SLIDE CONTROL Owner's Book PARAGON 2000 Xtra SLIDE CONTROL Owner's Book INCLUDES USER, INSTALLATION & MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start using the appliance Keep this booklet handy

More information

INSTALLATION AND OWNER GUIDE

INSTALLATION AND OWNER GUIDE 5136211/05 INSTALLATION AND OWNER GUIDE Model 961 Inset live fuel effect gas fire Incorporating the Valor Fires Control. Fitted with one of the following fascia Homeflame Dream Homeflame Masquerade Homeflame

More information

Plus Model BR645 VA (G.C )

Plus Model BR645 VA (G.C ) 600B656/05 Plus Model BR645 VA (G.C. 32-032-34) As supplied, this appliance is for use with natural gas (G20) When converted using conversion kit no. 591149 this appliance is for use with propane gas (G31)

More information

OWNER GUIDE. Sunfire II Radiant. Radiant / Convector Gas Fire. Model 347 (G. C. Number )

OWNER GUIDE. Sunfire II Radiant. Radiant / Convector Gas Fire. Model 347 (G. C. Number ) 5110946/01 OWNER GUIDE Sunfire II Radiant Radiant / Convector Gas Fire Model 347 (G. C. Number 32-032-62) THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) THIS APPLIANCE IS SUITABLE ONLY FOR INSTALLATION

More information

OWNER S GUIDE MODEL BR417 VA

OWNER S GUIDE MODEL BR417 VA 600B702/06 OWNER S GUIDE MODEL BR417 VA (G.C.32-032-07) Inset Live Fuel Effect Gas Fire with Ultimate Front AS SUPPLIED, THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) WHEN CONVERTED USING VALOR CONVERSION

More information

Orchestra COAL EFFECT BALANCED FLUE GAS FIRE

Orchestra COAL EFFECT BALANCED FLUE GAS FIRE Orchestra COAL EFFECT BALANCED FLUE GAS FIRE Installation and Maintenance Instructions Hand these instructions to the user Model No s FBFN76G & FBFN98G are for use on Natural Gas (G20) at a supply pressure

More information

MODEL 466 Radiant / Convector Gas Fire Black Beauty

MODEL 466 Radiant / Convector Gas Fire Black Beauty I N S T A L L E R G U I D E MODEL 466 Radiant / Convector Gas Fire Black Beauty Please keep in a safe place for future reference 600A734/02 Please leave this Installer Guide with the user This appliance

More information

Model 741FS. Dream, Heritage or Opulent OWNER GUIDE. INSTALLER: Please leave this guide with the owner Baxi Heating U.K. Limited 2007.

Model 741FS. Dream, Heritage or Opulent OWNER GUIDE. INSTALLER: Please leave this guide with the owner Baxi Heating U.K. Limited 2007. 5112500/02 Model 741FS Inset live fuel effect gas fire Incorporating the BAXI FIRES DIVISION CONTROL Fitted with one of the following fascia. Dream, Heritage or Opulent (GC No. 32-032-56) We trust that

More information

PARAGON FOCUS HE MULTI - FLUE SLIDE CONTROL

PARAGON FOCUS HE MULTI - FLUE SLIDE CONTROL PARAGON FOCUS HE MULTI - FLUE SLIDE CONTROL OWNER MANUAL INCLUDES USER INSTRUCTION & INSTALLATION & MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start installing or using

More information

OWNER GUIDE. Anthem, Bolero, Camden, Minima, Victorian or Westminster fascia

OWNER GUIDE. Anthem, Bolero, Camden, Minima, Victorian or Westminster fascia 5114465/01 OWNER GUIDE Model 741 INSET LIVE FUEL EFFECT GAS FIRE Fitted with Anthem, Bolero, Camden, Minima, Victorian or Westminster fascia (GC No. 32-032-56) THIS APPLIANCE IS FOR USE WITH NATURAL GAS

More information

INSTALLATION AND OWNER GUIDE

INSTALLATION AND OWNER GUIDE 5136066/01 INSTALLATION AND OWNER GUIDE Model 961 Inset live fuel effect gas fire Incorporating the Wonderfire Premier Control. Fitted with the Bauhaus fascia. (G.C. Number 32-032-88) We trust that this

More information

ENIGMA II SLIMLINE. Owner's Manual INCLUDES USER, INSTALLATION & MAINTENANCE INSTRUCTIONS

ENIGMA II SLIMLINE. Owner's Manual INCLUDES USER, INSTALLATION & MAINTENANCE INSTRUCTIONS ENIGMA II SLIMLINE Owner's Manual INCLUDES USER, INSTALLATION & MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start using the appliance Keep this booklet handy for future

More information

Model 940 Inset live fuel effect gas fire

Model 940 Inset live fuel effect gas fire 5122722/03 INSTALLER AND OWNER GUIDE Model 940 Inset live fuel effect gas fire Incorporating the VALOR FIRES CONTROL Fitted with one of the following fascia. Adorn, Decadent, Dream, Eternal, Icon, Obsession

More information

Napoli BF COAL EFFECT BALANCED FLUE GAS FIRE

Napoli BF COAL EFFECT BALANCED FLUE GAS FIRE Napoli BF COAL EFFECT BALANCED FLUE GAS FIRE Installation, Maintenance & User Instructions Hand these instructions to the user Model No. ABFC**MN2 & ABFC**EN3 are for use on Natural Gas (G20) at a supply

More information

ENIGMA HE Remote Control

ENIGMA HE Remote Control ENIGMA HE Remote Control OWNERS MANUAL INCLUDES USER INSTRUCTIONS & INSTALLATION & MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start installing or using this appliance

More information

OWNER GUIDE. Model 739 OPEN DECORATIVE GAS FIRE. (GC No )

OWNER GUIDE. Model 739 OPEN DECORATIVE GAS FIRE. (GC No ) 5113426/01 OWNER GUIDE Model 739 OPEN DECORATIVE GAS FIRE (GC No. 32-032-54) THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20). WHEN CONVERTED USING CONVERSION KIT NO. 0595211 THIS APPLIANCE IS FOR USE

More information

INSTALLER S GUIDE. Model BG C-2. (GC No ) INSET LIVE FUEL EFFECT GAS FIRE. (Manufacturer ref. BR658VA)

INSTALLER S GUIDE. Model BG C-2. (GC No ) INSET LIVE FUEL EFFECT GAS FIRE. (Manufacturer ref. BR658VA) 600B743/03 INSTALLER S GUIDE Model BG C-2 (GC No. 32-032-37) INSET LIVE FUEL EFFECT GAS FIRE (Manufacturer ref. BR658VA) THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) WHEN CONVERTED USING CONVERSION

More information

Adorn, Dream, Masquerade, Excelsior, Classica, Icon or Visage

Adorn, Dream, Masquerade, Excelsior, Classica, Icon or Visage 5122722/06 Please keep me in a safe place for future use. INSTALLER AND OWNER GUIDE Model 940 Inset live fuel effect gas fire Incorporating the VALOR CONTROL Fitted with one of the following fascia. Adorn,

More information

morsø PANTHER GAS STOVE

morsø PANTHER GAS STOVE morsø PANTHER GAS STOVE MODEL No. 553 OWNER S GUIDE This appliance meets the requirements of the European Gas Directive This guide is intended to help you care for your morsø gas stove. It gives sufficient

More information

Windsor HE HIGH EFFICIENCY FUEL EFFECT GAS FIRE

Windsor HE HIGH EFFICIENCY FUEL EFFECT GAS FIRE Windsor HE HIGH EFFICIENCY FUEL EFFECT GAS FIRE Installation, Maintenance & User Instructions Hand these instructions to the user Model No s FSHC**MN, FSHP**MN, FSHC**SN & FSHP**SN are for use on Natural

More information

Integra Convector Plus Manual

Integra Convector Plus Manual Integra Convector Plus Manual Inset Live Fuel Effect Gas Fire Installation and Users Instructions These instructions should be read by the installer before installation and then should be handed to the

More information

Model 341 Black Beauty Slimline

Model 341 Black Beauty Slimline 600B690/13 OWNER GUIDE Model 341 Black Beauty Slimline LIVE FUEL EFFECT GAS FIRE (GC No. 32-032-30) We trust that this guide gives sufficient details to enable this appliance to be operated and maintained

More information

Emberglow COAL EFFECT BALANCED FLUE GAS FIRE

Emberglow COAL EFFECT BALANCED FLUE GAS FIRE Emberglow COAL EFFECT BALANCED FLUE GAS FIRE User Instructions These instructions should be read by the user before operating the appliance and retained for future reference Model No. FEBC00MN is only

More information

Homeflame Bauhaus, Homeflame Dream or Homeflame Harmony. (G.C. Number )

Homeflame Bauhaus, Homeflame Dream or Homeflame Harmony. (G.C. Number ) 5130633/06 INSTALLATION AND OWNER GUIDE Model 961 Inset live fuel effect gas fire Incorporating the Valor Fires Control. Fitted with one of the following fascia Homeflame Bauhaus, Homeflame Dream or Homeflame

More information

Model 762 Inset live fuel effect gas fire

Model 762 Inset live fuel effect gas fire 5121278/04 INSTALLER AND OWNER GUIDE Model 762 Inset live fuel effect gas fire Fitted with the Homeflame Eminence fascia.. (G.C. Number 32-032-73) We trust that this guide gives sufficient details to enable

More information

Dovre 250 Cast Iron Gas Stove

Dovre 250 Cast Iron Gas Stove Dovre 50 Cast Iron Gas Stove NATURAL GAS AND LPG INSTALLATION, SERVICING AND USER INSTRUCTIONS THIS PRODUCT IS FOR USE ONLY IN GREAT BRITAIN AND IRELAND These instructions are to be left with the customer,

More information

INSTALLER GUIDE. Model 754. INSET LIVE FUEL EFFECT GAS FIRE Fitted with. Artura fascia. (GC No )

INSTALLER GUIDE. Model 754. INSET LIVE FUEL EFFECT GAS FIRE Fitted with. Artura fascia. (GC No ) 5113454/02 Model 754 INSET LIVE FUEL EFFECT GAS FIRE Fitted with Artura fascia (GC No. 32-032-59) THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20). THIS APPLIANCE IS SUITABLE ONLY FOR INSTALLATION IN THE

More information

RADIANT / CONVECTOR GAS FIRE MODEL 426 (GC ) INSTALLATION & SERVICING INSTRUCTIONS INSTALLER: Please leave these instructions with the owner

RADIANT / CONVECTOR GAS FIRE MODEL 426 (GC ) INSTALLATION & SERVICING INSTRUCTIONS INSTALLER: Please leave these instructions with the owner THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) AT A SUPPLY PRESSURE OF 20mbar (8in w.g.) THIS APPLIANCE IS FOR USE IN THE UNITED KINGDOM (GB) AND THE REPUBLIC OF IRELAND (IE) RADIANT / CONVECTOR GAS

More information

INSTALLATION AND OWNER GUIDE

INSTALLATION AND OWNER GUIDE 5136211/08 INSTALLATION AND OWNER GUIDE Model 961 Inset live fuel effect gas fire Incorporating the Valor Fires Control. Fitted with one of the following fascia Dream Homeflame Masquerade Homeflame Excelsior

More information

Model 942 Inset live fuel effect gas fire

Model 942 Inset live fuel effect gas fire 5122721/03 INSTALLER AND OWNER GUIDE Model 942 Inset live fuel effect gas fire Incorporating the VALOR FIRES CONTROL Fitted with one of the following fascia. Dream, Heritage or Opulent (GC No. 32-032-70)

More information

PARAGON ONE REMOTE Owner's Book

PARAGON ONE REMOTE Owner's Book PARAGON ONE REMOTE Owner's Book (THIS APPLIANCE IS FITTED WITH ALKALINE BATTERIES) INCLUDES USER, INSTALLATION & MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start using

More information

INSTALLER GUIDE MODEL BR417 VA. (G.C ) Inset Live Fuel Effect Gas Fire with Ultimate. Front

INSTALLER GUIDE MODEL BR417 VA. (G.C ) Inset Live Fuel Effect Gas Fire with Ultimate. Front 600B702/06 INSTALLER GUIDE MODEL BR417 VA (G.C.32-032-07) Inset Live Fuel Effect Gas Fire with Ultimate Front AS SUPPLIED, THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20). WHEN CONVERTED USING VALOR CONVERSION

More information

Full Depth Convector MC / SC

Full Depth Convector MC / SC Full Depth Convector MC / SC COAL EFFECT GAS FIRE Installation and Maintenance Instructions Hand these instructions to the user Model No s MICC**MN & MICC**SN are for use on Natural Gas (G20) at a supply

More information

Model 347 BLACK BEAUTY

Model 347 BLACK BEAUTY 110945/03 OWNER GUIDE Model 347 BLACK BEAUTY RADIANT / CONVECTOR GAS FIRE (G. C. No. 32-032-62) We trust that this guide gives sufficient details to enable this appliance to be operated and maintained

More information

Baxi Wentworth Classic Baxi Kingston 2 Classic

Baxi Wentworth Classic Baxi Kingston 2 Classic Baxi Wentworth Classic Baxi Kingston 2 Classic Please leave these instructions with the user Live Fuel Effect Inset Gas Fires Comp N o 244609 - Iss 4 6/00 Installation and Servicing Instructions Page 2

More information

INSTALLER AND OWNER GUIDE

INSTALLER AND OWNER GUIDE 5137188/05 INSTALLER AND OWNER GUIDE Model 963 Inset live fuel effect gas fire Incorporating the Valor Fires Control. Fitted with one of the following fascia: Homeflame Dream, Petrus, Masquerade or Excelsior.

More information

MODEL 466 Radiant / Convector Gas Fire Black Beauty

MODEL 466 Radiant / Convector Gas Fire Black Beauty O W N E R G U I D E MODEL 466 Radiant / Convector Gas Fire Black Beauty This Owner Guide is intended to help you care for your Valor gas fire. Please read carefully before using your gas fire and keep

More information

Kalahari RC & Camber RC

Kalahari RC & Camber RC Kalahari RC & Camber RC DECORATIVE FUEL EFFECT GAS FIRE User Instructions These instructions should be read by the user before operating the appliance and retained for future reference Model No s KRDC**RN

More information

Mesina Fires GLASS FRONT VENTED Model No. M 70

Mesina Fires GLASS FRONT VENTED Model No. M 70 Mesina Fires GLASS FRONT VENTED Model No. M 70 DECORATIVE COAL EFFECT NATURAL VENT GAS FIRE User Instructions These instructions should be read by the user before operating the appliance and retained for

More information

Model 348 Brava RADIANT / CONVECTOR GAS FIRE

Model 348 Brava RADIANT / CONVECTOR GAS FIRE 5134763/01 INSTALLATION AND OWNER GUIDE Model 348 Brava RADIANT / CONVECTOR GAS FIRE Incorporating the VALOR FIRES CONTROL (G.C. No. 32-032-90) We trust that this guide gives sufficient details to enable

More information

Rivas Plus INSET LIVE FUEL-EFFECT GAS FIRES. Hand these instructions to the owner following installation, they must be retained for future reference.

Rivas Plus INSET LIVE FUEL-EFFECT GAS FIRES. Hand these instructions to the owner following installation, they must be retained for future reference. Rivas Plus INSET LIVE FUEL-EFFECT GAS FIRES Installation, Maintenance & User Instructions. Hand these instructions to the owner following installation, they must be retained for future reference. Model

More information

STRATA BATTERY IGNITION RADIANT CONVECTOR GAS FIRE

STRATA BATTERY IGNITION RADIANT CONVECTOR GAS FIRE STRATA BATTERY IGNITION RADIANT CONVECTOR GAS FIRE Installation, Maintenance & User Instructions Hand these instructions to the user Model No s FORS**EN are for use on Natural Gas (G20) at a supply pressure

More information

FULL DEPTH HE GAS FIRE

FULL DEPTH HE GAS FIRE FULL DEPTH HE GAS FIRE USER INSTRUCTIONS INSTALLATION INSTRUCTIONS SERVICE INSTRUCTIONS It is a regulation that these instructions be handed to the customer after installation is complete. It is also the

More information

Model 956 OWNER GUIDE. This guide to be left with the owner INSET LIVE FUEL EFFECT GAS FIRE

Model 956 OWNER GUIDE. This guide to be left with the owner INSET LIVE FUEL EFFECT GAS FIRE 5118756/03 Model 956 INSET LIVE FUEL EFFECT GAS FIRE Fitted with one of the following fascia. Anthem, Aura 2, Blenheim, Bolero, Camden, Capri, Coast, Contemporary, Debut, Flare, Form, Fusion, Homeflame

More information

Broadway, Valor Landscape 2 Gas or Vermont fascia

Broadway, Valor Landscape 2 Gas or Vermont fascia 5122667/01 INSTALLER AND OWNER GUIDE Model 752 INSET LIVE FUEL EFFECT GAS FIRE Fitted with a Broadway, Valor Landscape 2 Gas or Vermont fascia (GC No. 32-032-74) We trust that this guide gives sufficient

More information

INSTALLER AND OWNER GUIDE. Incorporating the VALOR FIRES. Adorn, Decadent, Dream, Eternal, Icon, Obsession or Visage

INSTALLER AND OWNER GUIDE. Incorporating the VALOR FIRES. Adorn, Decadent, Dream, Eternal, Icon, Obsession or Visage 5122722/01 INSTALLER AND OWNER GUIDE Model 940 Inset live fuel effect gas fire Incorporating the VALOR FIRES CONTROL Fitted with one of the following fascia. Adorn, Decadent, Dream, Eternal, Icon, Obsession

More information

Owner s Manual INCLUDES. User, Maintenance, Service, and Installation Instructions Plus and 2000 Plus Extra Manual

Owner s Manual INCLUDES. User, Maintenance, Service, and Installation Instructions Plus and 2000 Plus Extra Manual Owner s Manual INCLUDES User, Maintenance, Service, and Installation Instructions 2000 Plus and 2000 Plus Extra Manual Keep this booklet for service log and future reference IMPORTANT This appliance is

More information

INSTALLER S GUIDE. MODEL 639 Open Decorative Gas Fire

INSTALLER S GUIDE. MODEL 639 Open Decorative Gas Fire 3002369/03 INSTALLER S GUIDE MODEL 639 Open Decorative Gas Fire (G.C No. 32-032-47) THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) WHEN CONVERTED USING CONVERSION KIT NO. 0591301 THIS APPLIANCE IS FOR

More information

INSTALLER GUIDE. Incorporating the BAXI FIRES DIVISION. Adorn, Decadent, Dream, Eternal, Icon, Obsession or Visage

INSTALLER GUIDE. Incorporating the BAXI FIRES DIVISION. Adorn, Decadent, Dream, Eternal, Icon, Obsession or Visage 5115978/02 INSTALLER GUIDE Model 740FS Inset live fuel effect gas fire Incorporating the BAXI FIRES DIVISION CONTROL Fitted with one of the following fascia. Adorn, Decadent, Dream, Eternal, Icon, Obsession

More information

GB IE. VALOR BOLERO (MODEL BR626) Inset Decorative Fuel Effect Gas Fires. For

GB IE. VALOR BOLERO (MODEL BR626) Inset Decorative Fuel Effect Gas Fires. For O W N E R G U I D E For VALOR BOLERO (MODEL BR626) Inset Decorative Fuel Effect Gas Fires GB IE This Owner Guide is intended to help you care for your Valor gas fire. Please read carefully before using

More information

INSTALLER GUIDE. Anthem, Bolero, Camden, Minima, Victorian or Westminster fascia

INSTALLER GUIDE. Anthem, Bolero, Camden, Minima, Victorian or Westminster fascia 5114465/01 INSTALLER GUIDE Model 741 INSET LIVE FUEL EFFECT GAS FIRE Fitted with Anthem, Bolero, Camden, Minima, Victorian or Westminster fascia (GC No. 32-032-56) THIS APPLIANCE IS FOR USE WITH NATURAL

More information

Squirrel - Gas Stoves

Squirrel - Gas Stoves Squirrel - Gas Stoves Model No. 551 - With Open Flue INSTALLATION INSTRUCTIONS This appliance is for use with natural gas (G20) When converted using conversion kit no. 555111 this appliance is for use

More information

Model 941 INSET LIVE FUEL EFFECT GAS FIRE

Model 941 INSET LIVE FUEL EFFECT GAS FIRE 5139632/01 INSTALLER AND OWNER GUIDE Please keep me in a safe place for future use. Model 941 INSET LIVE FUEL EFFECT GAS FIRE Fitted with one of the following fascia. Blenheim, Dream or Petrus. (GC No.

More information

Baxi Wentworth Deluxe Baxi Kingston 2 Deluxe

Baxi Wentworth Deluxe Baxi Kingston 2 Deluxe Baxi Wentworth Deluxe Baxi Kingston 2 Deluxe Please leave these instructions with the user Live Fuel Effect Inset Gas Fires Comp N o 244621 - Iss 5 6/00 Installation and Servicing Instructions Page 2 Natural

More information

Sonnet Plus Anthem Genesis Soraya

Sonnet Plus Anthem Genesis Soraya 5108617/01 INSTALLER GUIDE Sonnet Plus Anthem Genesis Soraya Model 746 (GC No. 32-032-57) INSET LIVE FUEL EFFECT GAS FIRE THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) WHEN CONVERTED USING CONVERSION

More information

Richmond Plus INSET LIVE FUEL-EFFECT GAS FIRES. Hand these instructions to the user after installation.

Richmond Plus INSET LIVE FUEL-EFFECT GAS FIRES. Hand these instructions to the user after installation. Richmond Plus INSET LIVE FUEL-EFFECT GAS FIRES Installation, Maintenance & User Instructions. Hand these instructions to the user after installation. Model No s FOPC**MN, FOPC**SN & FOPC**RN are for use

More information

OWNER GUIDE MODEL BR622 (GC ) INSET LIVE FUEL EFFECT GAS FIRE INCORPORATING. WITH ADORN, VISAGE, ELEGANT or ICON Front

OWNER GUIDE MODEL BR622 (GC ) INSET LIVE FUEL EFFECT GAS FIRE INCORPORATING. WITH ADORN, VISAGE, ELEGANT or ICON Front '19 act 2000 6008624/01 May 2000 OWNER GUIDE MODEL BR622 (GC32-032 - 09) INSET LIVE FUEL EFFECT GAS FIRE INCORPORATING THE ~ VALOR FireSl~'deCONTROL (E WITH ADORN, VISAGE, ELEGANT or ICON Front THIS APPLIANCE

More information

5traxo INSTALLATION AND SERVICING INSTRUCTIONS MANDATORY REQUIREMENTS INSTALLATION

5traxo INSTALLATION AND SERVICING INSTRUCTIONS MANDATORY REQUIREMENTS INSTALLATION 5traxo Division of Legge Fabheat Ltd Longfield Road, Sydenham, Leamington Spa CV31 1XB Tel. (0926) 882233 Fax (0926) 450846 Registered in England No. 500091 Universal INSTALLATION AND SERVICING INSTRUCTIONS

More information

INSTALLER GUIDE. Amour, Aspect, Aspect Glass, Eclipse, Fascination, Landscape, Serenity, Tranquility or Visia

INSTALLER GUIDE. Amour, Aspect, Aspect Glass, Eclipse, Fascination, Landscape, Serenity, Tranquility or Visia 5116154/03 Model 754 INSTALLER GUIDE INSET LIVE FUEL EFFECT GAS FIRE Fitted with one of the following fascia. Amour, Aspect, Aspect Glass, Eclipse, Fascination, Landscape, Serenity, Tranquility or Visia

More information

INSTALLATION & USER INSTRUCTIONS INSET DECORATIVE GAS FIRE

INSTALLATION & USER INSTRUCTIONS INSET DECORATIVE GAS FIRE INSTALLATION & USER INSTRUCTIONS INSET DECORATIVE GAS FIRE MODELS COVERED BY THESE INSTRUCTIONS HANNINGTON BRASS F500310 HANNINGTON BLACK F500311 Focal Point Fires plc. Christchurch, Dorset BH23 2BT Tel:

More information

INSTALLER AND OWNER GUIDE

INSTALLER AND OWNER GUIDE 5122721/02 INSTALLER AND OWNER GUIDE Model 942 Inset live fuel effect gas fire Incorporating the VALOR FIRES CONTROL Fitted with one of the following fascia. Dream, Heritage or Opulent (GC No. 32-032-70)

More information

Kalahari DECORATIVE FUEL EFFECT GAS FIRE

Kalahari DECORATIVE FUEL EFFECT GAS FIRE Kalahari DECORATIVE FUEL EFFECT GAS FIRE Installation and Maintenance Instructions Hand these instructions to the user Model No s KRDC00MN and KRDC00SN are for use on Natural Gas (G20) at a supply pressure

More information

Model 347 Black Beauty 4 Oxysafe RADIANT / CONVECTOR GAS FIRE

Model 347 Black Beauty 4 Oxysafe RADIANT / CONVECTOR GAS FIRE 5110945/07 INSTALLATION AND OWNER GUIDE Model 347 Black Beauty 4 Oxysafe RADIANT / CONVECTOR GAS FIRE (G.C. No. 32-032-62) We trust that this guide gives sufficient details to enable this appliance to

More information

MODEL 326 Radiant / Convector Gas Fire Sun~Fire

MODEL 326 Radiant / Convector Gas Fire Sun~Fire O W N E R G U I D E MODEL 326 Radiant / Convector Gas Fire Sun~Fire This Owner Guide is intended to help you care for your Valor gas fire. Please read carefully before using your gas fire and keep for

More information

INSTALLER AND OWNER GUIDE. Model 956 INSET MULTIFLUE GAS FIRE

INSTALLER AND OWNER GUIDE. Model 956 INSET MULTIFLUE GAS FIRE 5129357/02 INSTALLER AND OWNER GUIDE Model 956 INSET MULTIFLUE GAS FIRE (GC No. 32-811-47) We trust that this guide gives sufficient details to enable this appliance to be installed, maintained and operated

More information

PARAGON FOCUS 18 HE REMOTE

PARAGON FOCUS 18 HE REMOTE PARAGON FOCUS 18 HE REMOTE OWNER MANUAL INCLUDES USER INSTRUCTION & INSTALLATION & MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start installing or using this appliance

More information

Model 347. Firelite 4 Oxysafe Regency 4 Oxysafe INSTALLER GUIDE. INSTALLER: Please leave this guide with the owner RADIANT / CONVECTOR GAS FIRE

Model 347. Firelite 4 Oxysafe Regency 4 Oxysafe INSTALLER GUIDE. INSTALLER: Please leave this guide with the owner RADIANT / CONVECTOR GAS FIRE 5112105/02 Model 347 RADIANT / CONVECTOR GAS FIRE Fitted with one of the following fascia Firelite 4 Oxysafe Regency 4 Oxysafe (GC No. 32-032-62) We trust that this guide gives sufficient details to enable

More information

Castelle INSET FUEL EFFECT GAS FIRE. Hand these instructions to the user following installation

Castelle INSET FUEL EFFECT GAS FIRE. Hand these instructions to the user following installation Castelle INSET FUEL EFFECT GAS FIRE Installation, Maintenance & User Instructions Hand these instructions to the user following installation Model No s FPCL**RN is only for use on Natural Gas (G20) at

More information

Passion CONVENTIONAL FLUE LOG EFFECT GAS FIRE

Passion CONVENTIONAL FLUE LOG EFFECT GAS FIRE Passion CONVENTIONAL FLUE LOG EFFECT GAS FIRE Installation, Maintenance & User Instructions Hand these instructions to the user Model No. BLBL**RN & BLBL**TN is only for use on Natural Gas (G20) at a supply

More information

HAWK GAS STOVE. Installation and Servicing Instructions

HAWK GAS STOVE. Installation and Servicing Instructions HAWK GAS STOVE Installation and Servicing Instructions Please leave this instruction booklet with the user after the installation is complete. Leave the system ready for operation and instruct the user

More information

Conventional Flue. Instructions for Use, Installation and Servicing. For use in GB, IE (Great Britain and Republic of Ireland) IMPORTANT

Conventional Flue. Instructions for Use, Installation and Servicing. For use in GB, IE (Great Britain and Republic of Ireland) IMPORTANT Logic HE Range Conventional Flue Instructions for Use, Installation and Servicing For use in GB, IE (Great Britain and Republic of Ireland) IMPORTANT THE OUTER CASING, FRONT AND GLASS PANEL BECOME EXTREMELY

More information

Owner s Manual INCLUDES. PARAGON 2016 & PARAGON 2016 Hi IMPORTANT

Owner s Manual INCLUDES. PARAGON 2016 & PARAGON 2016 Hi IMPORTANT Owner s Manual INCLUDES User, Maintenance, Service, and Installation Instructions PARAGON 2016 & PARAGON 2016 Hi Keep this booklet for service log and future reference IMPORTANT This appliance is guaranteed

More information

E-Studio TM & E-Box TM

E-Studio TM & E-Box TM E-Studio TM & E-Box TM Conventional Flue with Upgradeable Control Valve E-box E-Studio Instructions for Use, Installation & Servicing For use in GB & IE (Great Britain & Republic of Ireland). IMPORTANT

More information

Model 339 Heartbeat Oxysafe 2

Model 339 Heartbeat Oxysafe 2 600B687/14 INSTALLER AND OWNER GUIDE Model 339 Heartbeat Oxysafe 2 LIVE FUEL EFFECT GAS FIRE (GC No. 32-032-29) We trust that this guide gives sufficient details to enable this appliance to be installed

More information

CRYSTAL FIRES VALENTINES BUILDING BECHERS DRIVE AINTREE RACECOURSE BUSINESS PARK LIVERPOOL MERSEYSIDE L9 5AY HEATRAVE S/L DECORATIVE INSET GAS FIRE

CRYSTAL FIRES VALENTINES BUILDING BECHERS DRIVE AINTREE RACECOURSE BUSINESS PARK LIVERPOOL MERSEYSIDE L9 5AY HEATRAVE S/L DECORATIVE INSET GAS FIRE CRYSTAL FIRES VALENTINES BUILDING BECHERS DRIVE AINTREE RACECOURSE BUSINESS PARK LIVERPOOL MERSEYSIDE L9 5AY HEATRAVE S/L DECORATIVE INSET GAS FIRE THIS APPLIANCE IS CAT I2H FOR USE WITH NATURAL GAS ONLY

More information

INSTALLER AND OWNER GUIDE

INSTALLER AND OWNER GUIDE 5110831/03 INSTALLER AND OWNER GUIDE Model 808 Electric Heater This guide is intended to help you install and care for your Baxi Fires Division electric heater. Please read carefully before installing

More information