Installation Instructions. SPANISH Installation Instructions. FRENCH Installation Instructions
|
|
- Dana Lucy Fox
- 5 years ago
- Views:
Transcription
1 Installation Instructions for Models 45, 90 and 190 Bypass Drum Humidifiers Inside Front Cover Model / Modelo / Modèle 45 Contractor: Read these instructions before installing or servicing humidifier. SPANISH Installation Instructions for Models 45, 90 and 190 Bypass Drum Humidifiers Page X Model / Modelo / Modèle 90 Contractor: Read these instructions before installing or servicing humidifier. FRENCH Installation Instructions for Models 45, 90 and 190 Bypass Drum Humidifiers Page XX Model / Modelo / Modèle 190 Contractor: Read these instructions before installing or servicing humidifier.
2 ENGLISH Contents Installation Alerts (Please read)... Below Skuttle Bypass Drum Humidifier Installation Instructions... 1 Español...X Français... XX Contractor Assistance: Phone: 888-SKUTTLE ( ) techservice@skuttle.com Web: Skuttle and the Happy House character are registered trademarks of Skuttle Mfg. Co. (DBA Skuttle Indoor Air Quality Products)! Installation Alerts DANGER: DO NOT cut or drill into air conditioning or electrical accessories during installation. WARNING: This bypass drum humidifier must be installed by a qualified heating and air conditioning contractor. Failure to comply could result in serious injury from electrical shock, damage to the humidifier or heating appliance, and/or void all warranties. CAUTIONS: 1. DO NOT install this humidifier with plastic water supply tubing. USE COPPER TUBING ONLY. 2. DO NOT install unit where freezing temperatures can occur. 3. DO NOT install unit where temperatures can exceed 180 F (82 C). 4. When installing this unit in an area where an overflow could result in water damage, install a suitable safety catch pan plumbed to a drain. 5. If the system contains a multi-speed blower motor, it is necessary to isolate the humidifier transformer to prevent premature burnout caused by the inductive current produced by the motor during high speed operation. This can be accomplished by several different types of wiring and accessories, such as using a pressure sensor or fan sail switch to detect blower operation, and an independent electrical circuit to power the humidifier transformer. Do not install U V lights near the unit. May cause the pad to deteriorate. NOTES: 1. You must comply with all local codes, ordinances and regulations pertaining to plumbing and electrical wiring. 2. The preferred power source for this unit is one that is independent of the furnace blower operation. 3. This humidifier is shipped as a right-hand bypass unit, and can be reversed. When reversing, make sure the float valve is mounted on the same side as the drum motor.
3 Skuttle Bypass Drum Humidifier Installation Instructions and drill five 7/64 in. (0.28 cm) mounting holes. Replace the cabinet and secure it with 1/2 in. (1.27 cm) screws. 4. On the inside of the humidifier cabinet whwere the bypass tube will connect, snap the drum shaft bearing in place with the U shape of the bearing facing up. 1. Determine the best location for the humi difier, based on the placement options, above. (Models 45 and 90 are shown; placement options for Model 190 are identical. 5. Install the collar on the other plenum and connect a bypass tube from the collar to the humidifier with sheet metal screws. (See below.) Model 45 = 5 in. (12.70 cm) collar and bypass tube Models 90 & 190 = 6 in. (15.24 cm) collar and bypass tube 2. Draw a level line on the plenum and tape the template (in carton) in position. Template Dimensions: Model 45 = 7-1/4 in. (18.42 cm) x 5-1/2 in. (13.97 cm) Models 90 & 190 = 8-3/4 in. (22.23 cm) x 7-1/4 in. (18.42 cm) Trace around the template with a marker, then remove the template. Carefully cut the rectangular opening. 3. DANGER: Do not cut or drill into air conditioning or electrical acces sories. Insert the humidifier cabinet into the opening, making sure it is level. Mark the location of the five mounting holes. Remove the cabinet 1 Seal connections with duct tape. If the furnace has air conditioning, set the duct damper for summer season shutoff. 6. Insert the overflow drain cup fitting into the bottom of the humidifier cabinet so that the cup is toward the front and on the same side as the OVERFLOW TUBE bypass tubing. Place the water pan in the unit with the overflow tube over the drain fitting.
4 Installation Instructions (continued) 7. Attach 3/8 in. (0.95 cm) I.D. tubing to the drain fitting and route it continuously downward to a suitable waste drain for overflow protection. Move the valve to the same side as the motor (if necessary). Insert the valve hole plug in the double D hole on the opposite side from the valve. 8. Assemble the drum and evaporator pad as shown at the bottom of the page. Install by inserting the drum and pad into the motor (coupling-end first), then connecting it to the saddle valve and humidifier. 9. CAUTION: Avoid contact with hot surfaces and sharp edges. Using the instructions on the valve bag, install the saddle valve on the nearest cold water pipe. Connect copper tubing, flush it, and route it to the humidifier. NOTE: For correct float valve and water tubing installation, see the float valve instruction card, located either on the humidifier water valve or in the parts bag. 10. Turn water on at the saddle valve. Adjust the water level to 1-3/8 in. (3.49 cm) deep by turning the adjustment screw on the valve clockwise ( ) to lower and counterclockwise ( ) to raise. DRUM AND EVAPORATOR PAD ASSEMBLY (See #8, above.) DANGER: To avoid shock or electro cution, TURN OFF THE ELECTRICAL POWER. NOTE: The preferred power source for this unit is one that is independent of the furnace blower operation. If the furnace is relatively new, check to see if there is an electronic control board with humidifier control terminals sometimes labeled HUM. (You may also consult the furnace installation manual or wiring diagram.) If humidifier terminals are present, proceed to No. 11A, below. If humidifier terminals are NOT present, answer the following questions: Is the blower motor powered with a supply greater than 120 volts? OR Does the blower motor change speed when the thermostat s system fan switch is activated during the heating mode? OR Does the blower motor change speed when the air conditioning is activated? If the answer to ANY of the above ques tions is YES, skip to No. 11B. If the answer to ALL of the above ques tions is NO, skip to No. 11C. 11A. Using a meter, check the terminals for power output during the heating cycle when the blower is running. Determine the output voltage. Some circuit boards have printed indicators. Most are 24 volt AC and only require con-
5 necting the drum motor and the humidi stat. (See Wiring Diagram A on page 3.) WIRING DIAGRAM A Terminals on Board humidifier and system operations. (See Wiring Diagram C, below.) WIRING DIAGRAM C Single-Speed Blower Replace If, in rare cases, the furnace terminals are 120 volt, connect the transformer to the terminals and wire as shown in Diagram C on right. 11B. For multi-speed blowers or systems not using 120 VAC, use the transformer (supplied) to coordinate humidifier operation with the system air mover. The source of power for the humidifier transformer should not be the blower motor wiring, but an independent source. This is to prevent transformer failure, either from feedback from the blower motor during air conditioning, or from voltage greater than the 120 volts required for the transformer. (See Wiring Diagram B, below.) WIRING DIAGRAM B Multi-Speed Blower Replace 11C. If you determine that the system blower motor is a 120 volt, single-speed motor, and that it does not change speed during the cooling mode, wire the transformer into the blower motor wiring. This will coordinate the 12. Follow the instructions n the humidistat parts bag to position and install the universal humidistat on either the ductwork or an appropriate wall. 13. Check the humidifier for proper operation. Turn on the water at the valve which leads directly to the humidifier. Make sure the water level is set at 1-3/8 in. (3.49 cm). Turn the valve screw clockwise ( ) to lower the water level; turn it counter clockwise ( ) to raise the water level. Turn the humidistat to its highest setting and observe the humidifier evaporator pad. If it does not rotate, turn the furnace on by increasing the thermostat temperature until the furnace blower comes on. This should cause the humidifier evaporator pad to NOTE: Wiring the humidifier to operate independently of or in conjunction with the furnace blower is up to the installer s discrition. On installations where the unit is closely sized (i.e., the cubic footage of the home is at or near the humidifier s peak volume capacity), independent operation allows the unit to operate throughout the full blower cycle, thereby eliminating the lag time involved in starting the humidifier. IMPORTANT: Reset the thermostat and humidistat to their correct positions for automatic operation. 3
6 The right combination of Skuttle products increases indoor air quality and creates a Happy House environment for you! Representative samples of Skuttle whole-house indoor air quality products are pictured above. L-R: high-capacity flow-thru humidifier, drum humidifier, stainless steel steam humidifier, UV germicidal and activated oxygen air purifier, HEPA filtration system, and make-up air control for proper ventilation. See all products and models in each product line at or ask a qualified HVAC contractor to recommend the appropriate combination of Skuttle Indoor Air Quality Products for your home. 101 Margaret Street Marietta, OH customerservice@skuttle.com Copyright Skuttle Mfg. Co All Rights Reserved Skuttle and the Happy House character are registered trademarks of Skuttle Mfg. Co. Part No M/HBP Rev
Installation Instructions Owner s Manual
Installation Instructions Owner s Manual FOR USE WITH GAS, OIL and HYDRONIC FORCED AIR FURNACES SEQUENCE OF OPERATION The AUTOFLO Model s SC15 & 250 use the evaporative principal to add moisture to the
More informationHE120, HE160 Humidifier Installation Kit
HE120, HE160 Humidifier Installation Kit INSTALLATION INSTRUCTIONS WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and
More informationinstallation and start-up instructions HUMIDIFIERS AND HUMIDISTAT
installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT HUM Cancels: II 912D-56-3 II HUM-56-1 7-98 MODEL HUMBBLFP1025-A-- FAN-POWERED HUMIDIFIER MODEL HUMBBLBP2018-A-- BYPASS HUMIDIFIER MODEL
More informationHE220, HE260 Humidifier Installation Kit
HE220, HE260 Humidifier Installation Kit WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and that your scratchy throat
More informationWiring Instructions. High-Capacity Steam Humidifiers
Wiring Instructions for High-Capacity Steam Humidifiers Including Instructions for Compensating Humidistat and Safety Control Shutoff CONTRACTOR: Read these instructions before installing or servicing
More informationRECOMMENDED LOCATION STEP BY STEP INSTALLATION. MODEL S 200P, 800BP and 97 POWER HUMIDIFIERS
FOR USE WITH ALL FORCED AIR SYSTEMS SEQUENCE OF OPERATION The AUTOFLO Model s 200P, 800BP and 97 Humidifiers use the evaporative by-pass principal to add moisture into the return air duct of your central
More informationContinue to next pages for Template instructions, Owners Guide, Humidistat Instructions.
This.Pdf document is for informational purposes only and contains an Installation Template. The Template in this.pdf document is not to scale. Do not use for sizing purposes. Continue to next pages for
More informationHE360 Humidifier Installation Kit
HE360 Humidifier Installation Kit INSTALLATION INSTRUCTIONS WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and that
More informationSkuttle. Indoor Air Quality Products. High Efficiency Air Cleaner Owner's Manual
To Buy: Contact Sylvane at 800-934-9194 or visit www.sylvane.com For Product Support: Contact Skuttle at 888-SKUTTLE Skuttle Indoor Air Quality Products High Efficiency Air Cleaner Owner's Manual WARNING:
More informationOWNER S MANUAL AND INSTALLATION INSTRUCTIONS. for Models 55 and 86 Under Duct Whole-House Humidifiers
OWNER S MANUAL AND INSTALLATION INSTRUCTIONS for Models 55 and 86 Under Duct Whole-House Humidifiers Includes Safety, Installation, Operating and Maintenance Instructions plus Warranty CAUTION: Read these
More informationInstallation Instructions
HUMBBSFP1016 HUMCCSFP1016 Small Fan Powered Humidifier and Humidistat Installation Instructions! WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death.
More informationDS 2001 REVISED Humidifier Assembly and Instruction Manual
DS 2001 REVISED Humidifier Assembly and Instruction Manual Contents Parts list Selecting a location Assembly Hanging the Basin Electrical connections Water connections 2 4 4 Installing the Disk Wheel Installing
More informationCUSTOMER SERVICE. Toll-free:
Rev Aug/1 Rotary Disc Humidifier (All Models) Installation & User Manual IMPORTANT Thank you for selecting the Desert Spring Rotary Disc Humidifier. Carefully read this manual before starting your installation.
More informationMODEL HUM HUMIDIFIERS
HOMEOWNER S MANUAL MODEL HUM HUMIDIFIERS Model HUMBBLFP1025-A-- Fan-Powered Humidifier Model HUMBBSFP1016-A-- Fan-Powered Humidifier Model HUMBBLBP2018-A-- Bypass Humidifier Model HUMBBSBP2017-A-- Bypass
More informationHUMIDIFIERS OWNERS MANUAL A GUIDE TO OPERATING AND MAINTAINING YOUR HUMIDIFIER 49FH, 49FP, 49BF, 49WS, & 49BG
49FH, 49FP, 49BF, 49WS, & 49BG HUMIDIFIERS READ AND SAVE THESE INSTRUCTIONS Model 49FH Fan-Powered A95248 Model 49FP Fan-Powered A95249 Model 49BF Bypass A95250 Model 49WS Water-Saver Bypass A95251 Model
More informationCAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS
DEHUMIDIFIERS 506451-01 04/2012 HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) FRONT VIEW (with alternate outlet location
More informationSafety, Installation, and Operation Manual
Automatic Steam Humidifier Control Safety, Installation, and Operation Manual READ COMPLETE INSTALLATION INSTRUCTIONS BEFORE STARTING. WARNING This product must be installed by a qualified heating and
More informationDuct Mount Rotating Drum Humidifier
Duct Mount Rotating Drum Humidifier Model 465-C1 Manual for: Installation Operation Maintenance Table of Contents Introduction...1 Specifications...1 Capacity Selection Guide...1 Installation Physical
More informationWITH TECHNICAL INFORMATION & REFERENCE GUIDE SKUTTLE HIGH-EFFICIENCY HUMIDIFIERS AIR CLEANERS MAKE-UP AIR CONTROLS AIR PURIFICATION
WITH TECHNICAL INFORMATION & REFERENCE GUIDE SKUTTLE HIGH-EFFICIENCY HUMIDIFIERS AIR CLEANERS MAKE-UP AIR CONTROLS AIR PURIFICATION Skuttle Indoor Air Quality Products Thank you for choosing Skuttle! As
More informationProduct Data. 49FH, 49FP, 49BF, 49WS, 49BG Humidifiers
HEATING & COOLING Product Data 49FH, 49FP, 49BF, 49WS, 49BG Humidifiers Model 49FH Model 49WS Model 49BF Model 49FP Model 49BG All Carrier humidifiers are designed for easy installation and quiet operation
More informationFLOW-THROUGH FURNACE HUMIDIFIER
FLOW-THROUGH FURNACE HUMIDIFIER Installation Warranty Maintenance Troubleshooting Guide 2 Installation READ COMPLETE INSTALLATION INSTRUCTIONS AND TEMPLATE BEFORE STARTING Attention Installer: Installation
More informationInstallation and Operation Manual
Model 8120X Digital Ventilation Controller CODE MIN/ HR Installation and Operation Manual TABLE OF CONTENTS WARNINGS AND CAUTIONS Warnings and Cautions... 3 Package Contents... 4 Specifications.... 4 Mounting
More informationTOTALINE HUMIDIFIERS HUMIDIFIES TOTALINE GOLD FLOW-THROUGH HUMIDIFIER
TOTALINE HUMIDIFIERS TOTALINE HUMIDIFIERS MAKE YOURSELF COMFORTABLE WITH TOTALINE It s easy. Just choose the Totaline quality humidifier that fits your needs. All Totaline humidifiers are designed for
More informationBYPASS AND POWER HUMIDIFIER OWNER S MANUAL
ResearchPr 57 Bypass v2 4/15/03 10:22 AM Page 1 READ AND SAVE THESE INSTRUCTIONS BYPASS AND POWER HUMIDIFIER OWNER S MANUAL Includes Safety, Operating, and Maintenance Instructions and Warranty ResearchPr
More informationAutomatic Digital Humidifier Control
Automatic Digital umidifier Control Safety and Installation Instructions EAD COMPLETE INSTALLATION INSTUCTIONS AND TEMPLATE BEFOE STATING. WANING ATTENTION INSTALLE: This product must be installed by a
More informationMODELS HUM HUMIDIFIERS. Form No. PDS HUM.56.1 HUMBBLFP1025-A-- HUMBBSFP1016-A-- HUMBBLBP2018-A-- HUMBBWTR2019-A-- HUMBBSBP2017-A--
HUMIDIFIERS MODELS HUM HUMBBLFP1025-A-- HUMBBSFP1016-A-- HUMBBLBP2018-A-- HUMBBWTR2019-A-- HUMBBSBP2017-A-- All Bryant humidifiers are designed for easy installation and quiet operation with heat pumps
More informationResidential Steam Humidifier
Residential Steam Humidifier Model HUMXXSTM3034 Residential Steam Humidifier Owner s Manual Includes Safety & Operating Instructions READ AND SAVE THESE INSTRUCTIONS TABLE OF CONTENTS Safety... 2 Introduction...
More informationProduct Data. HUM Humidifiers. FEATURES/BENEFITS (Bypass & Fan Powered Models) FAN POWERED MODELS BYPASS MODELS STEAM MODEL
HUM Humidifiers Product Data HUMXXLFP1518 FAN POWERED MODELS BYPASS MODELS HUMXXSFP1012 HUMBBLBP2417 HUMBBSBP2412 HUMBBWBP2417 (water saver) STEAM MODEL HUMXXSTM3034 Controlling indoor humidity is very
More informationProduct Data. HUM Humidifiers
Product Data HUM Humidifiers Model HUMCCLFP1025-A-- Model HUMCCSFP1016-A-- Model HUMCCLBP2018-A-- Model HUMCCWTR2019-A-- Model HUMCCSBP2017-A-- All Carrier humidifiers are designed for easy installation
More informationCAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents
IAQ HUMIDIFIERS Litho U.S.A. 2007 Dallas, Texas, USA 505,289M 08/2007 Supersedes 02/2007 KAZ # C.6046 HCWB2 & HCWP2 SERIES USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS Table Of Contents Introduction....................................
More informationCAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents
IAQ HUMIDIFIERS Litho U.S.A. 2007 Dallas, Texas, USA 505,289M 09/2008 Supersedes 08/2007 KAZ # C.6046 HCWB2 & HCWP2 SERIES USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS Table Of Contents Introduction....................................
More informationModel 1750A/ 1770A Dehumidifier Installation Instructions
Model 1750A/ 1770A Dehumidifier Installation Instructions Safety Instructions WARNING 1. Improper installation may cause property damage or injury. Installation, service, and maintenance must be performed
More informationfor the Programmable Humidifier Automatic Flushing Timer
INSTALLATION INSTRUCTIONS for the Programmable Humidifier Automatic Flushing Timer The Humidifier Automatic Flushing Timer automatically flushes accumulated mineral deposits from all central-system steam
More informationModel 8120 and 8126 Safety & Installation Instructions
Ventilation Controller Model 8120 and 8126 Safety & Installation Instructions FAMILIARIZE YOURSELF WITH THE INSTALLATION INSTRUCTIONS BEFORE STARTING DANGER ATTENTION INSTALLER: To prevent serious injury
More informationREAD AND SAVE THESE INSTRUCTIONS OWNER S MANUAL FOR BYPASS AND FAN POWERED HUMIDIFIERS. Small or Large Bypass 12 Water Saver Bypass 13 Fan Powered 14
READ AND SAVE THESE INSTRUCTIONS OWNER S MANUAL FOR BYPASS AND FAN POWERED HUMIDIFIERS Type Installed: Maintenance page: Small or Large Bypass 12 Water Saver Bypass 13 Fan Powered 14 Includes Safety, Operating
More informationHE225A,B and HE265A,B Bypass Flow-Through Humidifier
whole-house air quality system HE225A,B and HE265A,B Bypass Flow-Through Humidifier FEATURES/BENEFITS PRODUCT DATA Antimicrobial coating on pad prevents the surface growth and migration of bacteria, mold,
More informationINSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. Condensate Return Systems General Installation, Operation, & Service Instructions !
Condensate Return Systems General Installation, Operation, & Service Instructions INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. SAFETY INSTRUCTIONS This safety alert symbol will be used in this
More informationHEALTHY CLIMATE HUMIDIFIER
Humidifiers 0,880M /00 HEALTHY CLIMATE HUMIDIFIER OPERATING INSTRUCTIONS FOR MODELS WB-, WB-7, WB-7A, WP-8 & WP-8A Includes Safety, Operating, and Maintenance Instructions Introduction Thank you for your
More informationModel Smart Digital Humidistat
Model 072000 Smart Digital Humidistat Installation and Owner's Manual TB 213 P/N 090375A0213 REV. E December 5, 2006 Copyright 2004-2006, EWC Controls Inc., All Rights Reserved RH OD %RH TEMP Package includes:
More informationHE420A Steam Power Humidifier
READ AND SAVE THESE INSTRUCTIONS HE420A Steam Power Humidifier OWNER S GUIDE 69-1112-2 HE420A STEAM POWER HUMIDIFIER WELCOME... to the comfortable world of humidified air. With your Honeywell humidifier
More informationInstallation and Maintenance Manual IM 1102
Installation and Maintenance Manual IM 1102 Parallel Fan Powered Variable Air Volume (VAV) Terminal Box Group: Applied Air Systems Part Number: IM 1102 Date: October 2010 Model MQFVI5 Table of Contents
More informationInstallation Instructions
FAVXXR6C2100-A01 Vent Damper and Control Installation Instructions FAMILIARIZE YOURSELF WITH THE INSTALLATION INSTRUCTIONS BEFORE STARTING ATTENTION INSTALLER: This product must be installed by a qualified
More informationT-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N
T-SERIES Air Conditioner T43 Model INSTRUCTION MANUAL Rev. I P/N 10-1008-145 TABLE OF CONTENTS Warranty and Return Policy...2 IMPORTANT NOTICE...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING
More informationFan Powered and Bypass Humidifiers
Fan Powered and Bypass Humidifiers THUMD500APA00B - Fan Powered Humidifier THUMD300ABA00B - Large Bypass Humidifier THUMD200ABM00B - Small Bypass Humidifier THUMD500A THUMD200A/300A 2009 Trane PUB. NO.
More informationInstallation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier
RXID-AW90A Whole House Dehumidifier with fresh air ventilation Installation Guide Dehumidification Fresh Air Ventilation Compact Size Energy Efficient The whole house dehumidifier integrates highcapacity
More informationDIGI3U. Zoning Systems. Installation Guide. That s all we do. Three-Zone, Universal Controller for Gas/Electric or Heat Pump Applications
Installation Guide DIGIU Three-Zone, Universal Controller for Gas/Electric or Heat Pump Applications -Zone Controller for the RNC Market Part #DMAN October 004 Zoning Systems That s all we do. INTRODUCTION
More informationTEMSPEC INC. VERTICAL FAN COIL UNIT MODELS TVA, TVE, TVS
6720 Columbus Road Mississauga, Ontario Canada, L5T 2G1 Tel: (905) 670 3595 Fax: (905) 670 3592 Web: www.temspec.com TEMSPEC INC. VERTICAL FAN COIL UNIT MODELS TVA, TVE, TVS INSTALLATION AND MAINTENANCE
More informationCommStat 4 Controller
CommStat 4 Controller CommStat 4 Telecom HVAC Controller The CommStat 4 is an HVAC controller designed specifically for controlling two redundant air conditioners, heat pumps and air conditioners with
More informationHE420A,B and HE460A,B Steam Power Humidifiers OWNER S GUIDE
HE420A,B and HE460A,B Steam Power Humidifiers OWNER S GUIDE U.S. Registered Trademark Copyright 1998 Honeywell Inc. All Rights Reserved 69-1112-1 WELCOME... to the comfortable world of humidified air.
More informationREAD AND SAVE THESE INSTRUCTIONS. Centrifugal Atomizing Humidifier. Trion
READ AND SAVE THESE INSTRUCTIONS 707 Centrifugal Atomizing Humidifier Trion www.trioniaq.com Installation, Operation, & Maintenance Manual READ AND SAVE THESE INSTRUCTIONS LIRE ET CONSERVER CES INSTRUCTIONS
More informationMODELS HUM HUMIDIFIERS. Form No. PDS HUM Model HUMBBLFP1318 FEATURES/BENEFITS. Model HUMBBLBP2317. Model HUMBBSBP2312
HUMIDIFIERS MODELS HUM Model HUMBBLFP1318 Model HUMBBLBP2317 Controlling your indoor humidity is very important. In many cases the air inside a home is drier than a desert. Dry, indoor air is often the
More informationOPERATION AND MAINTENANCE INSTRUCTIONS FOR ROOF TOP HEAT PUMPS AND CEILING PLENUMS
OPERATION AND MAINTENANCE INSTRUCTIONS FOR ROOF TOP HEAT PUMPS AND CEILING PLENUMS RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1976H207 (10-06) PP TABLE OF CONTENTS I. General
More informationRXIH-AB12A and RXIH-AB17A By-Pass Flow-Through Humidifiers
RXIH-AB12A and RXIH-AB17A By-Pass Flow-Through Humidifiers with Antimicrobial OWNER S GUIDE Place bar code here 69-2297-01 IMPORTANT Please read these instructions and keep them in your records. OPERATING
More informationFLOW-THROUGH FURNACE HUMIDIFIER
FLOW-THROUGH FURNACE HUMIDIFIER Model 5000/6000 Warranty Maintenance Troubleshooting Guide 2 WARRANTY/MAINTENANCE/TROUBLE SHOOTING GUIDE WARRANTY The manufacturer guarantees the for the period of one year
More informationTEMPLATE Standard Operational Guideline RX Air 3000 Air Purifier
TEMPLATE Standard Operational Guideline RX Air 3000 Air Purifier PURPOSE: Purpose of Guideline: to assist staff in ensuring instructions are followed in setting up the equipment, operational requirements
More informationProduct Data. HUM Humidifiers FEATURES/BENEFITS
Humidifiers Product Data Large Fan Powered Model BBLFP1418 Controlling indoor humidity is very important. In many cases the air inside a home is drier than a desert. Dry, indoor air is often the culprit
More informationProduct Data. HUM Humidifiers FEATURES/BENEFITS
Product Data HUM Humidifiers Model HUMCCLFP1218 Model HUMCCLBP2217 Model HUMCCSBP2212 Controlling your indoor humidity is very important. In many cases the air inside a home is drier than a desert. Dry,
More informationModel 1820 Dehumidifier
Model 1820 Dehumidifier Installation Instructions SAFETY INSTRUCTIONS WARNING 1. 120 Volts may cause serious injury from electric shock. Disconnect electrical power before starting installation or servicing.
More informationINSTANT HOT WATER DISPENSER
INSTANT HOT WATER DISPENSER Tank Installation Materials required (not provided) 2 mounting bracket screws (and 2 plastic anchors if attaching to drywall) Shut-Off valve and T fitting Components When you
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS BUILT-IN BOTTOM MOUNT REFRIGERATOR/FREEZER DBRTGK72SS-GRILLE KIT (FOR designer SERIES ONLY) VIKING RANGE CORPORATION 111 Front Street Greenwood, Mississippi (MS) 38930 USA (662)
More informationRead and Save These Instructions All Hoods Must Be Installed By A Qualified Installer
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationComfortSTEAM TM. Humidification System
Notice to Contractor: Once installation is complete, please leave this manual with the customer for future reference. READ AND SAVE THESE INSTRUCTIONS Humidification System TRION www.trioniaq.com COMFORTSTEAM
More informationFCI500/600/FVI500/FCL/FVL600/FCQ-700 Installation and Maintenance Manual
FCI500/600/FVI500/FCL/FVL600/FCQ-700 Installation and Maintenance Manual FAN POWERED TERMINALS Receiving Inspection Prior to removing the shipping material, visually inspect the packing materials. There
More informationG-100ES Duct Mount Humidifier
G-100ES Duct Mount Humidifier Installation Operation Maintenance CAUTION: READ INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS CAREFULLY FOR SAFE OPERATION. EXERCISE EXTREME CAUTION WHEN WORKING
More informationModular Supply Make-Up Air Unit
Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features
More informationT-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N
T-SERIES Air Conditioner T20 Model INSTRUCTION MANUAL Rev. C P/N 89114993 TABLE OF CONTENTS Warranty and Return Policy... 2 IMPORTANT NOTICE... 2 RECEIVING THE AIR CONDITIONER... 3 HANDLING AND TESTING
More informationB SERIES ELECTRIC FURNACE
MISSISSAUGA, ONTARIO L5T 1H9 TEL.: 905-670-2500 FAX: 905-795-8311 CUSTOMER SERVICE TEL.: 1-888-882-7626 B SERIES ELECTRIC FURNACE! WARNING 1. The user MUST contact a specialized contractor when a failure
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS BUILT-IN BOTTOM MOUNT REFRIGERATOR/FREEZER BRTGK72SS-GRILLE KIT (FOR PROFESSIONAL SERIES ONLY) VIKING RANGE CORPORATION 111 Front Street Greenwood, Mississippi (MS) 38930 USA
More informationModel 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions
Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions ON/OFF button used to turn the ventilator on and off Up/Down buttons used to change humidity or vent time setting
More informationModel 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions
Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions ON/OFF button used to turn the ventilator on and off Up/Down buttons used to change humidity or vent time setting
More informationHumidifiers. Drum Type. Flow Through Type C31 12/07/13
12/07/13 Drum Type C31 Humidifiers Installs on vertical warm air supply or cold air return plenum All models include humidistat and installation package (transformer, solenoid valve, saddle valve & evaporator
More informationSeasonMaker Hi-Line Fan-coil Unit Model HSS S30 through S80
Installation & Maintenance Data IM 255-6 SeasonMaker Hi-Line Fan-coil Unit Model HSS S30 through S80 Group: Fan coil Part Number: # 106332400 Date: August 2000 Table of Contents Inspection............................................................................
More informationSteam Humidifier Fan Pack Installation & Maintenance Instructions
850 Steam Humidifier Fan Pack 5658 Fan Pack Service Part Steam Humidifier Fan Pack Installation & Maintenance Instructions TABLE OF CONTENTS Safety Cautions...2 Materials List...3 Operation...3 Specifications
More informationSafety & Installation Instructions
Premium Programmable Thermostat Safety & Installation Instructions Model 8570 READ AND SAVE THESE INSTRUCTIONS TABLE OF CONTENTS PAGE SPECIFICATIONS............................. 1 WIRE REQUIREMENTS.........................
More informationINSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER
INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER IMPORTANT MASSAGE TO INSTALLER: "The United States Environmental Protection Agency ("EPA") has issued various regulations regarding the
More informationDesiccant Dehumidifier
Since the 1950s Desiccant Dehumidifier Dry Spaces With NO Added Heat BMIL Technologies, LLC 4915 Arendell St., #313 Morehead City, NC 28557 PH 252-727-0994 FAX 252-727-0996 WWW.BMIL.COM Product Description
More informationG-100ES Duct Mount Humidifier
Warranty Limited Two Year Warranty This limited warranty covers Herrmidifier Residential Type s, excluding duct work, wiring and installation. Herrmidifier. warrants that all new Herrmidifier s are free
More informationHE365A,B Powered Flow-Through Humidifier
HE65A,B Powered Flow-Through Humidifier whole-house air quality system FEATURES/BENEFITS PRODUCT DATA Antimicrobial coating on pad prevents the surface growth and migration of bacteria, mold, fungus and
More informationRead and Save These Instructions
Model SL16 Installation & Owners Manual Humidifier GFI #5000 Read and Save These Instructions Installation by anyone other than a licensed contractor voids the warranty. Product designed for residential
More informationCommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET
CommStat 6 Controller for Redundant HVAC Systems PRODUCT DATA SHEET General Description The CommStat 6 HVAC controller is designed for controlling up to six redundant air conditioners in an E-House or
More informationCommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits
CommStat 4 PRODUCT DATA SHEET Controller for Redundant Telecom HVAC Systems General Description The CommStat 4 is an HVAC controller designed specifically for controlling two redundant air conditioners,
More informationREAD AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN
READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE
More informationInstallation & Operating Guide
5-036 HOT WATER TANK Installation & Operating Guide Read all instructions thoroughly. Keep this guide for future reference. Proof of purchase is required for Warranty. Staple receipt or proof of purchase
More informationCooktop Chimney Ventilation Hoods
INSTALLATION GUIDE Cooktop Chimney Ventilation Hoods Contents Wolf Cooktop Chimney Ventilation Hoods.......... 3 Cooktop Chimney Hood Specifications............ 4 Cooktop Chimney Hood Installation.............
More informationOPERATION AND MAINTENANCE INSTRUCTIONS FOR ROOF TOP HEAT PUMPS AND CEILING PLENUMS
OPERATION AND MAINTENANCE INSTRUCTIONS FOR ROOF TOP HEAT PUMPS AND CEILING PLENUMS TABLE OF CONTENTS I. General Information.................................................. 2 II. Standard Ceiling Plenum
More informationVertical Stack Fan Coil Units Models: TVA, TVE, TVS
6720 Columbus Road Mississauga, Ontario Canada, L5T 2G1 Tel: (905) 670 3595 Fax: (905) 670 3592 www.temspec.com Vertical Stack Fan Coil Units Models: TVA, TVE, TVS INSTALLATION, OPERATION AND MAINTENANCE
More informationSAFETY AND INSTALLATION MANUAL MODEL 8100
SAFETY AND INSTALLATION MANUAL ENERGY RECOVERY VENTILATORS MODEL 8100 Provides year-round fresh air Recovers 77% of the apparent heating or cooling energy from the exhausted air See Warnings Page 3 Table
More informationTECHNICAL BULLETIN. Model Smart Digital Humidistat. Installation and Owner's Manual. General Description
TECNICAL BULLETIN Model 072000 Smart Digital umidistat Installation and Owner's Manual TB 213 P/N 090375A0213 REV. G Copyright 2004-2008, EWC Controls Inc., All Rights Reserved R %R TEMP Package includes:
More informationDuct Mounted Atomizing Humidifier. Table of Contents
Duct Mounted Atomizing Humidifier Mister-MINI TM Table of Contents Introduction... 2 Specifications... 2 Capacity Selection Chart... 3 Output Capacity... 4 Installation Location Selection... 5 Mounting...
More informationINSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER
ASPEN MANUFACTURING 373 ATASCOCITA RD. HUMBLE, TX 77396 TEL (281) 441-6500 FAX (281) 441-6510 > INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER IMPORTANT: "The
More informationInstallation Instructions
CNPVP CNRVP Cased N Coils Upflow --- Downflow Heating --- Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...
More informationSPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS
036-21096-001 (0101) SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The
More informationInstallation & Maintenance Data IM Contents
Installation & Maintenance Data IM 254-4 Group: Fan Coil Part Number: 107133000 Date: June 1999 SeasonMaker HiLine Fan-coil Units Type KZZ Contents Inspection..................................... 2 Riser
More informationDuct Mount Atomizing Humidifier
Duct Mount Atomizing Mister 50 (24V) Mister 50-1 (120V) Manual for: Installation Operation Maintenance CAUTION: Read installation, operation, and maintenance instructions carefully for safe operation.
More informationLIFTAIRE II ELEVATOR AIR CONDITIONER
LIFTAIRE II ELEVATOR AIR CONDITIONER THE LATEST IN A SERIES OF AIR CONDITIONERS/HEATERS DESIGNED SPECIFICALLY FOR USE IN ELEVATORS. Airxcel, the maker of the #1 brand of air conditioners in the recreational
More informationMarvel S MICROPROCESSOR CONTROLLER. Installation, Operation and Maintenance Manual Effective October 2018 DISCONTINUED. For Reference Only
Marvel S MICROPROCESSOR CONTROLLER Installation, Operation and Maintenance Manual Effective October 2018 DISCONTINUED For Reference Only ***Interactive PDF*** Contents General Purpose...3 Standard And
More informationUSER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING
MODEL Premier Series 3000 USER MANUAL Non-Programmable Single Stage Heat/Cool Digital Thermostat Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single
More informationOWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference
3100 Premier Series Non-Programmable 2 Heat / 2Cool & Heat / Cool Digital Thermostat OWNERS MANUAL Compatible with low voltage multi-stage heat / cool systems with up to two stages of heating and two stages
More informationPWC-500/1000/1010/1500
SERVICE MANUAL for by Vertex Model PWC-500/1000/1010/1500 P/N man-7008 Table of Contents 1. Introduction 2. Cooler Set-up 3. Remove Top Cover 4. Remove/Replace Float 5. Remove/Replace Hot Tank 6. Faucet
More informationT-Series Air Conditioner T53 Model
INSTRUCTION MANUAL T-Series Air Conditioner T53 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200
More information