1 BOILERS AND WATER HEATERS Boilers BOILERS Vent (Chimney) Return Pressure Releif Valve Aquastat Air Vent Pressure Reducing Valve Water Feed Valve Flow Control Valve Supply Pressure / Temp Gauge Expansion Tank Circulator(s) (pump) Gas Valve Burners Drain Valve YOU SHOULD KNOW: IMC 005., M00.3: All boilers must have a shutoff valve in the supply and return piping (multiple boilers each boiler shall have an individual shutoff valve in the supply and return piping). M00.: Electrical and mechanical operating and safety controls for boilers shall be listed and labeled. IMC 00., M00.: Must have a pressure gauge and a temperature gauge or combination thereof (must indicate temperature and pressure within the normal range of the system s operation). M00.3: Steam boilers shall have a water-gauge glass and a pressure gauge (IMC 00.). IMC 006.3, M00.4: Boilers must be equipped with pressure-relief valves with minimum rated capacities for the equipment served (must be set at the maximum rating of the boiler). M00.4: Discharge from pressure-relief valve must be piped to drains by gravity to within 8" of the floor or to an open receptor. M00.5: All steam and hot water boilers shall be protected with a low-water cutoff control (IMC 007.). 6
2 BOILERS AND WATER HEATERS Expansion Tank EXPANSION TANK No. Code Description M003. Hot water boilers must be provided with an expansion tank. M003. Non pressurized expansion expansion tanks shall be securely fastened to the structure or boiler and supported to carry twice the weight of the tank filled with water. System Volume Pressurized Diaphragm Type Non-pressurized Type Capacity is based on an average water temperature of 95 F, fill pressure of psig and a maximum operating pressure of 30 psig System (volume) includes volume of water in boiler, convectors and piping, not including the expansion tank YOU SHOULD KNOW: M003..: Pressurized expansion tanks shall be consistent with the volume and capacity of the system and shall be capable of withstanding a hydrostatic test pressure of.5 times the allowable working pressure of the system. 7
3 Confined and Unconfined Space CONFINED AND UNCONFINED SPACE Height of Room Length of Room Width of Room Section IFGC Combustion Air is the air necessary for complete combustion of a fuel. When a fuel gas appliance is placed, proper air flow is critical for the fire to burn properly. You must determine first if the area is Confined or Unconfined. Confined: A space that has a volume of less than 50 cubic feet per,000 British thermal units per hour of the aggregate input rating of all appliances installed in that space. Unconfined: A space that has a volume NOT less than 50 cubic feet per,000 British thermal units per hour of the aggregate input ratings of all appliances installed in that space. If appliances are to be installed in a confined space, there are three types of ventilation covered in the code: Direct, Horizontal, Vertical. Each has different requirements for net ventilation. (see page 38) Always begin by determining whether appliances will be placed in confined or unconfined space. Step Step Determine CF of space: L 3 W 3 H of room. Identify total BTU s of appliance(s) to be installed. Step 3 Divide total BTU s by 000. Step 4 Multiply the quotient from Step 3 by 50. Step 5 If the product of Step 4 is less than the CF determined from Step, the space is unconfined. If it is greater than the CF as determined from Step, the space is considered to be confined. Move to the next page to size your vent openings. 8
4 Vertical Ducts to Attic VERTICAL DUCTS TO ATTIC W 3 L 5 min. sq. in. per 4,000 Btu/h W L = Airflow No. IFGC IRC Description G G Two openings must be provided. One within one foot of the ceiling and one within one foot of the floor. Where directly communicating with the outdoors, each opening shall have a minimum free area of square inch per 4,000 Btu/h of total input rating of all appliances in the enclosure. Example: Calculate the net opening (in square inches) required for a 45,000 BTU appliance. Step The total BTU s is 45,000 Step 45,000 divided by 4, The net area of the openings required for each of the two vents is.5 square inches. Round Duct Equivalent of Net Square Inches Required 3" 4" 5" 6" 7" 8" 9" 0" " 4"
5 Crawl Space and Attic Venting CRAWL SPACE AND ATTIC VENTING W 3 L 5 min. sq. in. per 4,000 Btu/h W L = Airflow No. IFGC IRC Description G G Two openings must be provided. One within one foot of the ceiling and one within one foot of the floor. Where directly communicating with the outdoors, each opening shall have a minimum free area of square inch per 4,000 Btu/h of total input rating of all appliances in the enclosure. Example: Calculate the net opening (in square inches) required for a 45,000 BTU appliance. Step The total BTU s is 45,000 Step 45,000 divided by 4, The net area of the openings required for each of the two vents is.5 square inches. Round Duct Equivalent of Net Square Inches Required 3" 4" 5" 6" 7" 8" 9" 0" " 4"
TASKS REGARDING COMBUSTION AIR
TASKS REGARDING COMBUSTION AIR DETERMINE IF THERE IS ENOUGH COMBUSTION AIR FOR THE TYPES OF APPLIANCES IN THE CAZ Use one of two methods, depending on appliance type and whether or not you have a blower
More informationpiping. COMBUSTION AIR CHAPTER 17
CHAPTER 17 COMBUSTION AIR SECTION M1701 GENERAL M1701.1 Air supply. Liquid and solid fuel-burning appliances shall be provided with a supply of air for fuel combustion, draft hood dilution and ventilation
More informationWATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E
WATER HEATERS / BOILERS -E PRODUCT SPECIFICATIONS Gas-Fired Steam Boiler Bulletin No. 20653 September 202 Supersedes Bulletin No. 20263 AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh MODEL NUMBER
More informationGSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES
P R O D U C T S P E C I F I C AT I O N S W A T E R H E A T E R S / B O I L E R S CONSERVATOR Gas-Fired Steam Boiler Bulletin No. 20263 October 200 Supersedes September 2008 AFUE up to 82.7% Heating Input
More information101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)
City of York Qdot Engineering 101 S. George St 116 E Gas Ave York, PA 17405 York, PA 17405 (717) 849-2329 (717) 744-8315 INSPECTION CHECKLIST Residential Mechanical 2009 Codes This checklist is intended
More informationGENERAL BASIC INSTALLATION INSTRUCTIONS DIRECT FIRED HOT WATER BOILERS PARKER BOILER CO.
GENERAL BASIC INSTALLATION INSTRUCTIONS DIRECT FIRED HOT WATER BOILERS PARKER BOILER CO. GBI 201-5 3C For a proper installation and in order to receive the best in operating life and efficiency from your
More informationGENERAL BASIC INSTALLATION INSTRUCTIONS INDIRECT GAS FIRED WATER HEATERS PARKER BOILER CO.
GENERAL BASIC INSTALLATION INSTRUCTIONS INDIRECT GAS FIRED WATER HEATERS PARKER BOILER CO. GBI 210 3C For a proper installation and in order to receive the best in operating life and efficiency from your
More informationINSTALLATION INSTRUCTIONS PLYMOUTH XTREME GAS-FIRED HOT WATER BOILERS
INSTALLATION INSTRUCTIONS These instructions must be affixed on or adjacent to the boiler. PLYMOUTH XTREME GAS-FIRED HOT WATER BOILERS These Gas-Fired water Boilers are low pressure, sectional cast iron
More information2012 INTERNATIONAL FUEL GAS CODE VENTS
2012 INTERNATIONAL FUEL GAS CODE SECTION 502 (IFGC) VENTS 502.1 General. All vents, except as provided in Section 503.7, shall be listed and labeled. Type B and BW vents shall be tested in accordance with
More informationJD Series Cast Iron Commercial Hot Water or Steam Boiler
JD Series Cast Iron Commercial Hot Water or Steam Boiler INSTALLATION, OPERATION & MAINTENANCE MANUAL An ISO 9001-2008 Certified Company Utica Boilers 2201 Dwyer Ave. Utica, NY 13501 Phone: (315) 797-1310
More informationFSB Series Gas-Fired Hot Water
FSB Series Gas-Fired Hot Water Induced Draft BOILERS INSTALLATION, OPERATION & MAINTENANCE MANUAL An ISO 9001-2000 Certified Company PENNCO BOILERS 85 Middle Rd. Dunkirk, NY 14048 www.ecrinternational.com
More informationA hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.
Introduction to Hydronics A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes. Hydronic heating systems use hot water or steam to deliver the
More informationChapter FUEL GAS CODE*
Chapter 19.09 FUEL GAS CODE* * Editors Note: Serial No. 2004-31, 1, adopted Oct. 11, 2004 amended Title 19 in its entirety to read as herein set out. See the editor's note at Tit. 19 and also the Code
More informationCHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2012 EDITION
CHAPTER 23.20 LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2012 EDITION Sections 23.20.100 Local amendments to the International Mechanical Code, 2012 Edition.... 2 23.20.101.2 Scope.... 2 23.20.103-110
More informationSection 9 - Tumble Dryers. Tumble Dryers LEPH
ON / SELECT STATUS PROGRAM Section 9 - Tumble Dryers Tumble Dryers LEPH264 Tumble Dryers Tumble dryers are rated by the American Gas Association based upon performance and a specific dry weight load. For
More informationINSTALLATION INSTRUCTIONS
PRODUCT LITERATURE Lennox Industries Inc. Dallas, Texas INSTALLATION INSTRUCTIONS COWB3 OIL FIRED BOILER RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE These instructions must be affixed on or adjacent
More informationHVAC Equipment Access Equipment Location
City of Lancaster- Building Department 121 East Chestnut Street, Suite 102, Lancaster, Ohio 43130-3825 (740) 687-6649, Fax (740) 681-5030 Web site: www.ci.lancaster.oh.us/dept/building HVAC Heating, Ventilating,
More informationC O D E S & A M M E N D M E N T S
SEVIER COUNTY UTILITY DISTRICT SEPTEMBER 2, 2014 Sevier County Utility District has adopted the 2009 International Fuel Gas Code for gas inspections. The following pages contain frequently used codes and
More informationSERIES II OIL-FIRED CAST IRON HOT WATER BOILER
Model No. UH3KW0.60 UH3KW0.75 UH3KW1.00 UH4KW0.90 UH4KW1.25 UH4KW1.50 UH5KW1.20 UH5KW1.75 UH5KW2.00 SERIES II OIL-FIRED CAST IRON HOT WATER BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL Manufactured
More informationBuilding Department Informational Handout
City of Sonoma Building Department Informational Handout Residential Water Heaters Handout No: 15 Revised: 4/26/18 A water heater is an appliance designed to supply hot water and is equipped with automatic
More informationDo not use this vent pipe or fittings for venting incinerators of any kind.
! CAUTION! Do not use this vent pipe or fittings for venting incinerators of any kind. C.S.A. Certified For Natural Gas Or Propane Tested For 100 LBS. ASME Working Pressure For correct installation of
More informationCHAPTER 10 STEAM AND HOT WATER BOILERS
CHAPTER 10 STEAM AND HOT WATER BOILERS 1001.0 Purpose. The purpose of this chapter is to establish and provide minimum standards for the protection of public welfare, health, safety, and property by regulating
More informationGil Rossmiller. In the construction industry for over 30 years. ICC IRC Plumbing & Mechanical Code Development Committee
Gil Rossmiller In the construction industry for over 30 years ICC IRC Plumbing & Mechanical Code Development Committee ICC- IECC Commercial Energy Code Development Committee Building Official Parker, Colorado
More informationInspection Checklist Mechanical Final
Property Owner Name: Property Address: Property Parcel Number: Inspectors Name: Review Date: Permits and Plans 1. Job address is posted in a visible location. (R319.1) 2. Permit and approved plans, and
More informationBryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired
Form No. 8700 Bryan Flexible Water Tube TM Triple-Flex Series Ultra-High Efficiency Condensing Hot Water Boilers 3,000,000 BTUH Natural Gas Fired Minimum 90% Thermal Efficiency at 160 F Return with 20
More informationSTARFIRE IV SERIES 4 WATER OIL FIRED CAST IRON BOILER
Models SFH-3085 SFH-3100 SFH-4100 SFH-4125 SFH-4145 SFH-5160 SFH-5185 SFH-6175 SFH-6210 STARFIRE IV SERIES 4 WATER OIL FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL Tested For 75
More informationCHAPTER 1 ADMINISTRATION SECTION 101 (IFGC) GENERAL
CHAPTER 1 ADMINISTRATION SECTION 101 (IFGC) GENERAL 101.1 Title. These regulations shall be known as the North Carolina Fuel Gas Code as adopted by the North Carolina Building Code Council on March 11,
More informationAFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh
WATER HEATERS / BOILERS COWB3 Oil-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 0654 March 08 Supersedes September 05 AFUE up to 85.% Heating Input 05,000 to 45,000 Btuh MODEL NUMBER IDENTIFICATION
More informationSTARFIRE IV SERIES 4 WATER OIL FIRED CAST IRON BOILER
Models SFH-3085 SFH-3100 SFH-4100 SFH-4125 SFH-4145 SFH-5160 SFH-5185 SFH-6175 SFH-6210 STARFIRE IV SERIES 4 WATER OIL FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL Tested For 75
More informationCHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2000 EDITION
CHAPTER 23.20 LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2000 EDITION SECTIONS 23.20.100 Local Amendments To The International Mechanical Code, 2000 Edition 23.20.202 Definitions 23.20.301.14
More informationSTEAM / GAS APPLICATION GUIDE
WET-BASE CAST-IRON MODULAR BOILERS Guidelines for the design, purchase and installation of Slant/Fin gas-fired steam modular boiler systems. STEAM / GAS APPLICATION GUIDE CONTENTS Introduction...1 Ratings
More informationCity of Chanhassen. Site address. Ventilation Quantity (Determine quantity by using Table R or Equation R )
City of Chanhassen 7700 Market Blvd. - PO box 147 - Chanhassen, MN 55317 Phone 952-227-1180 - Fax 952-227-1190 - Web www.ci.chanhassen.mn.us Ventilation, Makeup and Combustion Air Calculations Instructions
More informationAMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER
AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER The 2016 Denver Building and Fire Code includes the following codes except as amendment herein. 2015 IBC (Building) 2015 IFC (Fire)
More informationCHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2006 EDITION
CHAPTER 23.20 LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2006 EDITION Sections 23.20.100 Local amendments to the International Mechanical Code, 2006 Edition... 2 23.20.101.2 Scope... 2 23.20.303.4
More informationCombustion Appliance Safety Testing Guidelines
Combustion Appliance Safety Testing Guidelines This guide is intended to assist home performance contractors complete all combustion safety tests adequately and safely according to the Building Performance
More informationAFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh
HEATERS / BOILERS GWB8-E Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 065 July 06 Supersedes September 05 AFUE up to 83.9% Heating Input 50,000 to 99,000 Btuh MODEL NUMBER IDENTIFICATION
More informationREAD ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter X X X X X X X X X X Adopt Entire Chapter as amended (amended sections listed below)
CALIFORNIA MECANICAL CODE MATRIX ADOPTION TABLE CAPTER CIMNEY AND VENTS (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency authority and building
More informationSERIES 19A. mith PRESSURIZED WET BASE
SERIES 19A mith series19a BOILER/BURNER PRESSURIZED WET BASE UNIT series 19A STANDARD EQUIPMENT All s Cast iron wet-base sections tested for 80psi. Insulated metal jacket Cast iron smokehood with integral
More informationVenting of Gas Fired Equipment RV
PLEASE DO NOT BOOKMARK ANY ANYTIMECE WEBPAGES! Our system will remember the last page you viewed when logging out and back in but please DO NOT exit out when taking a test. Your place will NOT be saved.
More informationCHIMNEY INSTALLATION. Technical Bulletin #1
Technical Bulletin #1 CHIMNEY INSTALLATION A chimney performs two functions: it removes smoke and flue gases from the stove/furnace, and it provides draft for the fire. Draft is the term used to describe
More informationInspection Checklist Mechanical Rough in
Property Owner Name: Property Address: Permit Number: Inspectors Name: Review Date: Permits and Plans 1. Job address is posted in a visible location. (R319.1) 2. Permit and approved plans are on site and
More informationHOME INSPECTOR EDUCATION EXPO 2016
An Education in Hot Water HOME INSPECTOR EDUCATION EXPO 2016 Residential Water Heater Inspection Course Objective Course Objective Completing this course should enable an inspector to identify components
More informationBC Series II OIL-FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR US AND CANADIAN SALES
Models BC3095 BC4100 BC4115 BC Series II OIL-FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR US AND CANADIAN SALES Maximum Allowable Working Pressure 30 psi. Manufactured by: ECR
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS G1D80BT, G1D80BR, G2D80CT, & G2D80CR 80% Gas Furnace with System Sentry Control System WARNING Improper installation, adjustment, alteration, service, or maintenance can cause
More informationCHAPTER 7 WATER HEATING EQUIPMENT AND VENTS
CAPTER 7 WATER EATING EQUIPMENT AND VENTS Part I 71. General. 71.1 Scope Applicability. The regulations of this chapter shall govern the construction, location, and installation of fuelburning water heating
More informationInspection Checklist Residential Mechanical Rough In July 2016
Inspection Checklist Residential Mechanical Rough In July 2016 This Inspection Checklist reflects code requirements of the 2015 International Residential Code (IRC), the 2015 Uniform Plumbing Code (UPC),
More informationVICTORYII. Cast-iron, power vent gas boiler BOILER FOR OLDER HOMES.
VICTORYII Cast-iron, power vent gas boiler VHS SERIES are available in a sealed combustion model VSPH VICTORY BOILERS AN IDEAL REPLACEMENT BOILER FOR OLDER HOMES. A PERFECT BOILER FOR NEW CONSTRUCTION.
More informationMI/MIH. Series. Gas. Boilers. Installation, Operation & Maintenance Manual
Series Gas MI/MIH Boilers Installation, Operation & Maintenance Manual TABLE OF CONTENTS TABLE OF CONTENTS USING THIS MANUAL 1 A. INSTALLATION SEQUENCE.............1 B. SPECIAL ATTENTION BOXES...........1
More informationCHURCH MUTUAL AND HARTFORD STEAM BOILER SENSOR TECHNOLOGY PROGRAM: IDENTIFYING FROZEN PIPE EXPOSURES
CHURCH MUTUAL AND HARTFORD STEAM BOILER SENSOR TECHNOLOGY PROGRAM: IDENTIFYING FROZEN PIPE EXPOSURES Where to Install Pipe Temperature Sensors for Freeze Protection 1 WHICH PIPES SHOULD I MONITOR FOR FREEZE
More informationInstallation and Operating Service Manual
Installation and Operating Service Manual FORCED DRAFT WATER BOILERS Bryan Steam LLC, 783 N. Chili Avenue, Peru, IN 46970, Phone 765.473.6651, Fax 765.473.3074 www.bryanboilers.com Form 2020 Revision Date
More informationProduct Data. ama. BW1, BW2 & BW3 Gas-Fired Water Boilers Series B
BW1, BW2 & BW3 Gas-Fired Water Boilers Series B Product Data MODEL BW1, BW2 Series B MODEL BW3 Series B MODELS BW1, BW2, and BW3 Models BW1 and BW2 Gas-Fired Hot Water Boilers provide fast heat quietly
More informationGARCIA GALUSKA DESOUSA Consulting Engineers
L#56566/Page 1/May 23, 2017 HVAC Heating Plant The original Town Hall building and Addition building are primarily heated by a gas fired hot water plant that is located in the basement. The boiler plant
More informationInstallation Operation Service Manual
Installation Operation Service Manual for Forced Draft Water Boilers BRYAN BOILERS 783 N. CHILI AVENUE, PERU, INDIANA 46970 Telephone: 765-473-6651 / Fax: 765-473-3074 E-Mail: bryanboilers@iquest.net /
More informationCertification Information. Qualifications. Test Specifications. Gas Hydronics Industry References
GAS HYDRONICS INSTALLATION CERTIFICATION Certification Information Scope - Tests a candidate's knowledge of the installation, service, maintenance, and repair of hot water heating systems. System sizes
More informationINSTALLATION AND OPERATING INSTRUCTIONS Models Type H, WH, & P
INSTALLATION AND OPERATING INSTRUCTIONS Models 302-902 Type H, WH, & P CATALOG NO. 1000.50K Effective: 08-01-03 Replaces: 01-15-03 FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors
More informationCHAPTER 6 SPECIFIC APPLIANCES
CHAPTER SPECIFIC APPLIANCES SECTION 01 (IFGC) GENERAL 01.1 Scope. This chapter shall govern the approval, design, installation, construction, maintenance, alteration and repair of the appliances and equipment
More information2012 International Fuel Gas Code Design, Installation and Inspection Principles
Overview 2012 International Fuel Gas Code Design, Installation and Inspection Principles Based on the 2012 International Fuel Gas Code Administration Definitions General regulations Gas piping installations
More informationIFGC-2012 AMENDED IFGC-2015 IFGC-2018 CHAPTER 1 SCOPE AND
CHAPTER 1 SCOPE AND CHAPTER 1 SCOPE AND ADMINISTRATION ADMINISTRATION 301.1.2 LP-Gas installations. Whenever there is a conflict between this code and NFPA 54 and B+NFOA 58 as adopted by the Nevada LP-Gas
More informationIndiana WX Oil Furnace Inspection Guide
Indiana WX Oil Furnace Inspection Guide Client: Job # : Address: Phone: Client Interview: Oil Dealer: Date of last service: Comments/Billing information: Standard Inspection / Clean and Tune Follow-up:
More informationA-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents
Boiler specifications A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents Burner General: Q. Burner and burner safeguards shall comply with the CGA
More information2012 UPC Chapter 5 Water Heaters RV
PLEASE DO NOT BOOKMARK ANY ANYTIMECE WEBPAGES! Our system will remember the last page you viewed when logging out and back in but please DO NOT exit out when taking a test. Your place will NOT be saved.
More informationSite address. Ventilation Quantity (Determine quantity by using Table N or Equation 11-1) Continuous ventilation
City of Victoria Building Inspections Department 7951 Rose Street P. O. Box 36 Victoria, MN 55386 (952) 443-4210 Ventilation, Makeup and Combustion Air Calculations Instructions and Example These instructions
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS G1D91BT, CG90TB, & G1D93BT High Efficiency 90+ Condensing Gas Furnace WARNING Improper installation, adjustment, alteration, service, or maintenance can cause injury or property
More informationFundamentals of the 2012 International Mechanical Code
Fundamentals of the 2012 International Mechanical Code Brent Ursenbach Salt Lake County PDS 385-468-6694 bursenbach@slco.org bursenbach@yahoo.com 2 IMC 101.2 Scope This code shall regulate the design,
More informationSide by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions
Installation instructions Cascade Venting System for RTG 199HE Side by side 6720804520-20.1V Extension Set for units 3 or 4-7 736 501 254 6 720 811 761 / 238-50976-00A (2014/05) Table of contents Table
More informationPlease read before proceeding
Boiler Manual Please read before proceeding Installer Read all instructions before installing. Follow all instructions in proper order to prevent personal injury or death. Consider piping and installation
More informationDRI-STEEM Models GTS
READ AND SAVE THESE INSTRUCTIONS This manual must be left with the owner and should be accessible for reference. DRI-STEEM Models GTS and GTS-DI GAS-TO-STEAM HUMIDIFIERS Installation, Operation and Maintenance
More information2015 MECHANICAL CODE REQUIREMENTS
2015 MECHANICAL CODE REQUIREMENTS ANTRIM COUNTY BUILDING DEPARTMENT PO BOX 188 205 CAYUGA STREET BELLAIRE, MI 49615 (231) 533-8373 FAX (231) 533-6041 Mechanical requirements for residential buildings per
More informationSection 2, Reference publications: Updated the referenced publications to the current editions.
Summary of Substantive Changes between the 2014 and the 2015 editions of ANSI Z21.10.3 CSA 4.3 Gas fired water heaters, volume III, storage water heaters with input ratings above 75,000 Btu per hour, circulating
More informationWhole House Combustion Appliance Safety Test Procedure for Pacific Gas and Electric Company (PG&E) Advanced Home Upgrade 2019
Whole House Combustion Appliance Safety Test Procedure for Pacific Gas and Electric Company (PG&E) Advanced Home Upgrade 2019 Note: This procedure is subject to revision or modification by PG&E at any
More informationPLYMOUTH STEAM SERIES 2 GAS-FIRED STEAM BOILERS
PLYMOUTH STEAM SERIES 2 GAS-FIRED STEAM BOILERS INSTALLATION, OPERATION & MAINTENANCE MANUAL MODEL PVSB Continuous Pilot MODEL PSB Electronic Intermittent Ignition H ECR International, Inc. 2201 Dwyer
More informationBack to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions
Installation instructions Cascade Venting System for RTG 199HE Back to back Basic Set for units 1 and 2-7 736 501 253 6 720 811 762 / 238-50973-00A (2014/05) Table of contents Table of contents 1 Key to
More informationINSTALLATION, OPERATING AND SERVICE INSTRUCTIONS EVA SERIES BOILER
INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS EVA SERIES BOILER MODULATION Price - $3.00 A SM File Number MH25585 H E For Service and repairs to the heating plant, call your heating contractor. When
More informationGASEOUS HYDROGEN SYSTEMS
CHAPTER 7 GASEOUS HYDROGEN SYSTEMS SECTION 701 GENERAL 701.1 Scope. The installation of gaseous hydrogen systems shall comply with this chapter and Chapters 30 and 35 of the Fire Compressed gases shall
More informationESC IV STEAM SERIES 4 OIL-FIRED CAST IRON BOILER
ESC IV STEAM SERIES 4 OIL-FIRED CAST IRON BOILER MODELS ESC-3090S ESC-3090ST ESC-4125S ESC-4125ST ESC-5185S ESC-5185ST ESC-6210S ESC-6210ST INSTALLATION, OPERATION & MAINTENANCE MANUAL PATENT 7,823,544
More informationTABLE 3A BUILDING PERMIT AND PLAN REVIEW FEES
ROUTT COUNTY REGIONAL BUILDING DEPARTMENT 136 6 th Street * P.O. Box 773840 * Steamboat SpringsCO80477 (970)870-5566 * FAX (970)870-5489* Email: Building@co.routt.co.us TABLE 3A BUILDING PERMIT AND PLAN
More informationContents Chapters 4 & 5 of the 2012 Michigan Mechanical Code CHAPTER 4, MMC: VENTILATION CHAPTER 5, MMC: EXHAUST SYSTEMS
Contents Chapters 4 & 5 of the 2012 Michigan Mechanical Code CHAPTER 4, MMC: VENTILATION CHAPTER 5, MMC: EXHAUST SYSTEMS 1 Ventilation and Exhaust 2 Seminar Introduction Seminar addresses key concepts
More informationHome Performance Science
Home Performance Science Symptoms of a Sick House Too hot/too cold rooms Respiratory problems Headaches/nausea Smoky fireplace Foggy windows Stuffy air and lingering odors Peeling paint Constant dust problems
More informationWausau Fire Department Inspection Violation Code Listing (Modified) All Applicable Records
VIOLATION Code AISLES/EXITS NFPA 1-14.13.2.1 NFPA 1-14.4.1 NFPA 1-14.4.2.1 NFPA 101-7.10.9 Violation Codes Description Aisles and Exits Emergency Lighting Working Required emergency lighting systems shall
More information(UNIVERSAL BOX) FOR USE ONLY WITH A LISTED GAS- FIRED UNVENTED DECORATIVE ROOM HEATER NOT TO EXCEED 40,000 BTU/H. DO NOT BUILD A WOOD FIRE
BUCK STOVE MODEL ZCBB VENTLESS FIREBOX ENCLOSURE FOR GAS-FIRED DECORATIVE TYPE UNVENTED ROOM HEATERS FOR USE WITH OPTIONAL WOODEN FLUSH MOUNT MANTEL (FF) AND OPTIONAL WOODEN SURROUND (WS) (UNIVERSAL BOX)
More informationAdopting Agency BSC SFM. Adopt Entire Chapter X X X X X X X X X X Adopt Entire Chapter as amended (amended sections listed below)
CALIFORNIA MECANICAL CODE MATRIX ADOPTION TABLE CAPTER CIMNEY AND VENTS Adopting Agency BSC SFM CD DSA OSPD 1 1/AC AC SS SS/CC 1 4 Adopt Entire Chapter X X X X X X X X X X Adopt Entire Chapter as amended
More informationUH16 Series Gas Fired Steam Boilers
UH16 Series Gas Fired Steam Boilers Models UH1603HSID UH1604HSID UH1605HSID UH1606HSID UH1607HSID UH1608HSID UH1609HSID INSTALLATION, OPERATION & MAINTENANCE MANUAL MODEL HSID Electronic Intermittent Ignition
More informationCHAPTER 8 CHIMNEYS AND VENTS
CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.
More informationWATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh
HEATERS / BOILERS GWB8-E PRODUCT SPECIFICATIONS Gas-Fired Hot Water Boiler Bulletin No. 065 September 0 Supersedes Bulletin No. 06 AFUE up to 83.9% Heating Input 50,000 to 99,000 Btuh MODEL NUMBER IDENTIFICATION
More information16 Series GAS-FIRED STEAM BOILERS MODELS
16 Series GAS-FIRED STEAM BOILERS MODELS 1603HSID 1604HSID 1605HSID 1606HSID 1607HSID 1608HSID 1609HSID INSTALLATION, OPERATION & MAINTENANCE MANUAL MODEL HSID Electronic Intermittent Ignition PENNCO BOILERS
More information4.3 Installing Appliances and Interior Vapor Distribution Systems Performance-Based Skills Assessment 2016
4.3 Installing Appliances and Interior Vapor Distribution Systems Performance-Based Skills Assessment 2016 Section One Task 1 Task 2 Task 3 Task 4 Task 5 Section Two Task 1 Task 2 Task 3 Task 4 Task 5
More informationLADERA. Traditional. Fireplace Design Collection EPA WOOD BURNING FIREPLACES
LADERA EPA WOOD BURNING FIREPLACES Traditional Fireplace Design Collection SHOW YOURSELF Create a room that begs you to stick around, sit down and relax. IN FEATURED Ladera fireplace with White Stacked
More information2009 International Residential Code Draft of New Fire Sprinkler Related Requirements
1. IRC Sections R313 and R314, insert two new sections as follows: R313 FIRE SPRINKLER SYSTEM FOR TOWNHOUSES R313.1 Required Installation. An automatic residential fire sprinkler system shall be installed
More informationInstallation and maintenance instructions
6304 0309 04/2005 US For heating engineers Installation and maintenance instructions Sealed combustion gas boiler Logano GA124 CAUTION! Observe the safety instructions of this installation and maintenance
More informationINSTALLATION, OPERATING AND SERVICE INSTRUCTIONS EVO SERIES BOILER
INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS EVO SERIES BOILER ON/OFF AND MODULATION, OUTDOOR Price - $3.00 A SM File Number MH25585 H E For Service and repairs to the heating plant, call your heating
More informationDEFINITIONS CHAPTER 2
CHAPTER 2 DEFINITIONS SECTION 201 (IFGC) GENERAL 201.1 Scope. Unless otherwise expressly stated, the following words and terms shall, for the purposes of this code and standard, have the meanings indicated
More informationINSTALLATION, OPERATING AND SERVICE INSTRUCTIONS EVCA SERIES CONDENSING BOILER
INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS EVCA SERIES CONDENSING BOILER Price - $3.00 A SM File Number MH25585 H E For service and repairs to the heating plant, call your heating contractor. When
More informationCommercial Water Heaters. Genesis. Water Heater Design Guide
Commercial Water Heaters Genesis Water Heater Design Guide Dear Customer, This Genesis Water Heater Design Guide is intended to explain, simplify and help in the planning and the installation of our Genesis
More informationVentilation, Makeup and Combustion Air Calculations Submittal Form New Dwellings
Ventilation, Makeup and Combustion Air Calculations Submittal Form New Dwellings Site Address Contractor Contractor Email Contractor Phone Date SECTION A Square feet * Number of bedrooms Ventilation Quantity
More informationSPECIFIC APPLIANCES CHAPTER 6
CHAPTER 6 SPECIFIC APPLIANCES SECTION 601 (IFGC) GENERAL 601.1 Scope. This chapter shall govern the approval, design, installation, construction, maintenance, alteration and repair of the appliances and
More informationEXTROL EXPANSION TANKS
EXTROL EXPANSION TANKS For Closed Hydronic Heating & Chilled Water Systems MADE IN USA SINCE 954 AMTROL Quality Expansion Tanks Table of Contents AMTROL Quality Expansion Tanks... 2 How It Works... 2 The
More informationX Article/Section 902.0(D) X X X X X X X X X X X
CALIFORNIA MECHANICAL CODE MATRIX ADOPTION TABLE CHAPTER 9 INSTALLATION OF SPECIFIC APPLIANCES Adopting Agency BSC SFM HCD DSA OSHPD 1 2 1/AC AC SS SS/CC 1 2 3 4 Adopt Entire Chapter X X X X X Adopt Entire
More information1 Exam Prep Florida Building Code-Mechanical Tabs and Highlights
1 Exam Prep Florida Building Code-Mechanical Tabs and s These 1 Exam Prep Tabs are based on Florida Building Code-Mechanical, 2014. Each 1 Exam Prep tabs sheet has five rows of tabs. Start with the first
More informationSurround Yourself With COMFORT AND WARMTH. VENT-FREE FAN CONVECTORS
Surround Yourself With COMFORT AND WARMTH. VENT-FREE FAN CONVECTORS 2 ENHANCE THE COMFORT OF the spaces you love. At Rinnai, a passion for creating products that perform at their very best has always driven
More informationRESIDENTIAL GAS-FIRED WATER HEATERS OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS
RESIDENTIAL GAS-FIRED WATER HEATERS (EQUIPPED WITH FVIR TECHNOLOGY) OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS This water heater IS NOT design certified for installation in a manufactured (mobile)
More information