Tranquility Console (TRC) Series Submittal Data

Size: px
Start display at page:

Download "Tranquility Console (TRC) Series Submittal Data"

Transcription

1 Tranquility Console (TRC) Series Submittal Data Models TRC Hz - HFC-410A *LC386* LC386 Rev.: June 19, 2017

2 Table of Contents TRC Console Series Unit Features 3 Selection Procedure 4 TRC Series Nomenclature 6 Performance Data AHRI/ASHRAE/ISO Performance Data Selection Notes 8 Performance Data TRC09 9 Performance Data TRC12 10 Performance Data TRC15 11 Performance Data TRC18 12 Performance Data Correction Tables 13 Blower Performance & Electrical Data 14 Physical Data 15 Console Cabinet Dimensions Size Bottom Return - Left Hand Piping 16 Console Cabinet Dimensions Size Front Return - Left Hand Piping 17 Console Cabinet Dimensions Size Bottom Return - Right Hand Piping 18 Console Cabinet Dimensions Size Front Return - Right Hand Piping 19 Console Bottom Return Chassis Dimensions Size Console Front Return Chassis Dimensions Size Piping Detail Size Console Cabinet Dimensions Size 18 - Bottom Return - Left Hand Piping 23 Console Cabinet Dimensions Size 18 - Front Return - Left Hand Piping 24 Console Cabinet Dimensions Size 18 - Bottom Return - Right Hand Piping 25 Console Chassis Dimensions Size 18 - Front Return - Right Hand Piping 26 Console Bottom Return Chassis Dimensions Size Console Chassis Dimensions Size Piping Detail Size TRC Series Wiring Diagram Matrix 30 Typical Wiring Diagram Manual & Auto Change Over TRC Units with CXM Controller 31 Typical Wiring Diagram Remote Mounted Thermostat TRC Units with CXM Controller 32 Typical Wiring Diagram TRC Units with CXM & MPC Controller 33 Typical Wiring Diagram Manual & Auto Change Over TRC Units with DXM Controller 34 Typical Wiring Diagram Remote Mounted Thermostat TRC Units with DXM Controller 35 Engineering Specifications 36 Performance Sheet 45 Revision History 47 Document page number is shown next to part number (e.g. LC386-3 = page 3). Since not all pages are typically used in the submittals process, the page number in the lower right corner can still be used (page of ). LC386-2

3 Unit Features TRANQUILITY CONSOLE (TRC) SERIES WITH EARTHPURE HFC-410A REFRIGERANT The Tranquility Series (TRC) console unit provides a high efficiency WSHP ductless solution for spaces where individual, quiet control of the heating and cooling system is important. TRC units are especially ideal where ceiling height and space are limited, or when preserving the integrity of an existing structure. The TRC Series exceeds ASHRAE 90.1 efficiencies, yet maintains small cabinet dimensions. Using EarthPure HFC-410A refrigerant, the Tranquility console not only protects the environment, it does so while delivering unprecedented comfort, efficiency, and reliability. Available in sizes 3/4 ton (2.64 kw) through 1-1/2 tons (5.3 kw) with numerous cabinet, water piping and control choices, the TRC Series offers a wide range of units for most any installation. The TRC has an extended range refrigerant circuit, capable of ground loop (geothermal) applications as well as water loop (boiler-tower) applications. Standard features are many. Microprocessor controls, galvanized steel cabinet, polyester powder coat paint and TXV refrigerant metering device are just some of the features of the flexible TRC series. Compressors are mounted on specially engineered soundtested EPDM grommets for quiet operation. Options such as coated air coil, DDC controls, internal pump and factoryinstalled water solenoid valves allow customized design solutions. The TRC Series console water-source heat pumps are designed to meet the challenges of today s HVAC demands with a low cost/high value ductless solution. UNIT FEATURES Sizes 09 (3/4 ton, 2.64 kw) through 18 (1-1/2 ton, 5.3 kw Environmentally-friendly EarthPure (HFC-410A) zero ozone depletion refrigerant High Efficiency Rotary compressors Exceeds ASHRAE 90.1 efficiencies Two-piece chassis/cabinet design Galvanized steel cabinet with durable Polar Ice powder coat finish and black matte finish on subbase Slope top/aluminum rigid bar supply air grille UltraQuiet Option TXV metering device Extended range (20 to 120 F, -6.7 to 48.9 C) operation Advanced digital auto change-over unit mounted controls with temperature display and high/low fan speed selection Remote-mounted controls available Microprocessor controls standard (optional DXM and/or DDC controls) LonWorks, BACnet, Modbus and Johnson N2 compatibility options for DDC controls Right or left-hand piping arrangement Front or bottom return air configuration Unit Performance Sentinel performance monitoring system Eight Safeties Standard Wide variety of options including coated air coil, flow regulator, motorized water valve, stainless steel drain pan, locking control door, disconnect switch, and internal pump. (Pump option requires extended cabinet). Accessory Louvered, painted black matte finish subbase decorative grille for field-installation. LC386-3

4 Selection Procedure Reference Calculations Heating LWT = EWT - LAT = EAT + HE GPM x 500 HC CFM x1.08 HR LWT = EWT + GPM x 500 LAT (DB) = EAT (DB) - Cooling SC CFM x1.08 LC = TC - SC S/T = SC TC Legend and Glossary of Abbreviations BTUH = BTU( British Thermal Unit) per hour HWC = hot water generator (desuperheater) capacity, Mbtuh CFM = airflow, cubic feet/minute FPT = female pipe thread COP = coefficient of performance = BTUH output/btuh input KW = total power unit input, kilowatts DB = dry bulb temperature ( F) LAT = leaving air temperature, F EAT = entering air temperature, Fahrenheit (dry bulb/wet bulb) LC = latent cooling capacity, BTUH EER = energy efficiency ratio = BTUH output/watt input LWT = leaving water temperature, F MPT = male pipe thread ESP = external static pressure (inches w.g.) EWT = entering water temperature GPM = water flow in U.S. gallons/minute HE = total heat of extraction, BTUH HC = air heating capacity, BTUH HR = total heat of rejection, BTUH MBTUH = 1000 BTU per hour S/T = sensible to total cooling ratio SC = sensible cooling capacity, BTUH TC = total cooling capacity, BTUH WB = wet bulb temperature ( F) WPD = waterside pressure drop (psi & ft. of hd.) Conversion Table - to convert inch-pound (English) to S-I (Metric) Air Flow Water Flow Ext Static Pressure Water Pressure Drop Airflow (L/s) = CFM x Water Flow (L/s) = gpm x ESP (Pa) = ESP (in of wg) x 249 PD (kpa) = PD (ft of hd) x 2.99 LC386-4

5 Selection Procedure Step 1 Step 2 Determine the actual heating and cooling loads at the desired dry bulb and wet bulb conditions. Obtain the following de sign parameters: Entering water temperature, water flow rate in GPM, air flow in CFM, water flow pressure drop and design wet and dry bulb temperatures. Air flow CFM should be between 300 and 450 CFM per ton. Unit water pressure drop should be kept as close as possible to each other to make water balancing easier. Go to the ap pro pri ate tables and find the proper indicated water flow and water tem per a ture. Step 3 Select a unit based on total and sensible cooling conditions. Select a unit which is closest to, but no larger than, the actual cooling load. Step 4 Enter tables at the design water flow and water temperature. Read the total and sensible cooling capacities (Note: interpolation is per mis si ble, ex trap o la tion is not). Example Equipment Selection For Cool ing Step 1 Load Determination: Assume we have determined that the appropriate cooling load at the desired dry bulb 80 F and wet bulb 65 F con di tions is as follows: Total Cooling...10,200 BTUH Sensible Cooling...8,350 BTUH Entering Air Temp...80 F Dry Bulb/65 F Wet Bulb Step 2 Design Conditions: Similarly, we have also obtained the following design pa ram e ters: Entering Water Temp...90 F Water Flow (Based upon 12 F rise in temp.) GPM Air Flow CFM Step 3, 4 & 5 HP Selection: Step 5 Step 6 Step 7 Step 8 Read the heating capacity. If it exceeds the design criteria it is acceptable. It is quite normal for Water- Source Heat Pumps to be selected on cooling capacity only since the heating output is usually greater than the cooling capacity. Determine the correction factors associated with the variable factors of dry bulb and wet bulb. Corrected Total Cooling = tabulated total cooling x wet bulb correction. Corrected Sensible Cooling = tabulated sensible cooling x wet/dry bulb correction. Compare the corrected capacities to the load re quire ments. Normally if the capacities are within 10% of the loads, the equipment is ac cept able. It is better to undersize than oversize, as undersizing improves humidity control, reduces sound levels and extends the life of the equip ment. When completed, calculate water temperature rise and assess the selection. If the units selected are not within 10% of the load cal cu la tions, then review what effect chang ing the GPM, water temperature and/or air flow and air tem per a ture would have on the corrected capacities. If the desired capacity cannot be achieved, select the next larger or smaller unit and repeat the procedure. Remember, when in doubt, undersize slightly for best performance. After making our preliminary selection (TRC12), we enter the tables at design water flow and water tem per a ture and read Total Cooling, Sens. Cooling and Heat of Rej. ca pac i ties: Total Cooling...10,800 BTUH Sensible Cooling...9,200 BTUH Heat of Rejection...13,900 BTUH Step 6 & 7 Entering Air and Airflow Corrections: Next, we determine our correction factors. Table Ent Air Air Flow Cor rect ed Corrected Total Cooling = 10,800 x x =10,056 Corrected Sens Cooling = 9,200 x x = 9,134 Corrected Heat of Reject = 13,900 x x = 13,037 Step 8 Water Temperature Rise Calculation & As sess ment: Actual Temperature Rise F When we compare the Corrected Total Cooling and Corrected Sensible Cooling figures with our load re quire ments stated in Step 1, we discover that our selection is within +/- 10% of our sensible load requirement. Fur ther more, we see that our Cor rect ed Total Cooling figure is slightly undersized as recommended, when compared to the actual in di cat ed load. LC386-5

6 TRC Series Nomenclature Model Type TRC = Console OPTION A B D F K T R C Unit Size 09, 12, 15, 18 Revision Level B = Current Revision B G C Voltage G = /60/1 A = 115/60/1 E = 265/60/1 Controls C = ACO Unit Mounted Tstat w/cxm D = ACO Unit Mounted Tstat w/dxm R = Remote Mounted Tstat w/cxm S = Remote Mounted Tstat w/dxm L = Remote Mounted w/cxm & LON M = Remote Mounted w/dxm & LON N = Remote Mounted w/cxm & MPC P = Remote Mounted w/dxm & MPC POWER TERMINATION & OPTIONS FIELD CONNECTED (HARD WIRE) X Amp PLUG & CORD - X - - X DISCONNECT SWITCH X X BREAKER - - X - - RECEPTACLE X A S S C S R S Heat Exchanger Options A = Copper Water Coil w/ e-coated Air Coil C = Copper Water Coil J = Cupro-nickel Water Coil w/ e-coated Air Coil Subbase Standard S = Standard Piping Connections R = Right Piping L = Left Piping V = Left Piping w/ss Drain Pan W = Right Piping w/ss Drain Pan Water Circuit Options Sweat FPT MPT None S F M Motorized Water Valve A G N Autoflow (2.25 Gpm/Ton) B H P Autoflow (3.0 Gpm/Ton) C J Q Motorized Water Valve & Afr (2.25) D K R Motorized Water Valve & Afr (3.0) E L T Secondary Circulation Pump U V W N = Cupro-nickel Water Coil V = Copper Water Coil w/ e-coated Air Coil & Extended Range Insulation E = Copper Water Coil w/extended Range Insulation M = Cupro-nickel Water Coil w/ e-coated Air Coil & Extended Range Insulation F = Cupro-nickel Water Coil w/extended Range Insulation S = 5 Subbase H = 5 Subbase w/motorized Damper N = None * 1 = 5 Subbase for Chassis Only 2 = 5 Subbase w/motorized Damper for Chassis Only Cabinet Construction With UltraQuiet M = Bottom Return D = Bottom Return w/locking Control Door B = Front Return E = Front Return w/locking Control Door C = No Cabinet BR Chassis Only J = No Cabinet FR Chassis Only A = Bottom Return w/extended Cabinet K = Bottom Return w/locking Control Door w/extended Cabinet P = Front Return w/extended Cabinet Q = Front Return w/locking Control Door w/extended Cabinet Without UltraQuiet S = Bottom Return L = Bottom Return w/locking Control Door F = Front Return G = Front Return w/locking Control Door N = No Cabinet BR Chassis Only H = No Cabinet FR Chassis Only R = Bottom Return w/extended Cabinet T = Bottom Return w/locking Control Door w/extended Cabinet U = Front Return w/extended Cabinet V = Front Return w/locking Control Door w/extended Cabinet *Requires extended unit - see cabinet dimensions. LC386-6

7 Performance Data AHRI/ASHRAE/ISO ASHRAE/AHRI/ISO English (I-P) Units Model Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump Cooling 86 F Heating 68 F Cooling 59 F Heating 50 F Cooling 77 F Heating 32 F Capacity Btuh EER Btuh/W Capacity Btuh COP Capacity Btuh EER Btuh/W Capacity Btuh COP Capacity Btuh EER Btuh/W Capacity Btuh TRC09 8, , , , , , TRC12 11, , , , , , TRC15 13, , , , , , TRC18 15, , , , , , Cooling capacities based upon 80.6 F DB, 66.2 F WB entering air temperature Heating capacities based upon 68 F DB, 59 F WB entering air temperature All air fl ow is rated on high speed, Units factory shipped on medium and low motor taps. All ratings based upon operation at lower voltage of dual voltage rated models COP ASHRAE/AHRI/ISO Metric (S-I) Units Model Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump Cooling 30 C Heating 20 C Cooling 15 C Heating 10 C Cooling 25 C Heating 0 C Capacity kw EER W/W Capacity kw COP Capacity kw EER W/W Capacity kw COP Capacity kw EER W/W Capacity kw TRC TRC TRC TRC Cooling capacities based upon 27 C DB, 19 C WB entering air temperature Heating capacities based upon 20 C DB, 15 C WB entering air temperature All air fl ow is rated on high speed, Units factory shipped on medium and low motor taps. All ratings based upon operation at lower voltage of dual voltage rated models COP LC386-7

8 Performance Data Selection Notes For operation in the shaded area when water is used in lieu of an antifreeze solution, the LWT (Leaving Water Temperature) must be calculated. Flow must be maintained to a level such that the LWT is maintained above 42 F [5.6 C] when the JW3 jumper is not clipped (see example below). Otherwise, appropriate levels of a proper antifreeze solution should be used in systems with leaving water temperatures of 42ºF [5.6 C] or below and the JW3 jumper should be clipped. This is due to the potential of the refrigerant temperature being as low as 32 F [0 C] with 40 F [4.4 C] LWT, which may lead to a nuisance cutout due to the activation of the Low Temperature Protection. JW3 should never be clipped for standard range equipment or systems without antifreeze. Example: At 50 F EWT (Entering Water Temperature) and 1.5 gpm/ton, a 3 ton unit has a HE of 22,500 Btuh. To calculate LWT, rearrange the formula for HE as follows: HE = TD x GPM x 500, where HE = Heat of Extraction (Btuh); TD = temperature difference (EWT - LWT) and GPM = U.S. Gallons per Minute. TD = HE / (GPM x 500) TD = 22,500 / (4.5 x 500) Heating - EAT 70 F EER HC kw HE LAT COP ed TD = 10 F LWT = EWT - TD LWT = = 40 F In this example, a higher flow rate will be required for EWTs at or below 50 F without antifreeze. At 2 gpm/ton, the calculation above results in a TD of 7.5. LWT = = 42.5 F, which is above 42 F EWT, and is acceptable for this application. LC386-8

9 Performance Data TRC CFM Nominal (Rated) Airflow EWT F GPM WPD* Cooling - EAT 80/67 F Heating - EAT 70 F PSI FT TC SC Sens/ Tot Ratio kw HR EER HC kw HE LAT COP Operation not recommended Performance capacities shown in thousands of Btuh *WPD Adder for Motorized Valve, TRC09 (Cv = 4.9, MOPD = 150 psi) GPM WPD Adder PSI FT Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80 F DB and 67 F WB in cooling, and 70 F DB in heating. AHRI/ISO certifi ed conditions are 80.6 F DB and 66.2 F WB in cooling and 68 F DB in heating. Table does not refl ect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40 F EWT is based upon a 15% methanol antifreeze solution. Operation below 60 F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. LC386-9

10 Performance Data TRC CFM Nominal (Rated) Airflow EWT F GPM Performance capacities shown in thousands of Btuh WPD* Cooling - EAT 80/67 F Heating - EAT 70 F PSI FT TC SC Sens/ Tot Ratio kw HR EER HC kw HE LAT COP Operation not recommended *WPD Adder for Motorized Valve, TRC12 (Cv = 4.9, MOPD = 150 psi) GPM WPD Adder PSI FT Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80 F DB and 67 F WB in cooling, and 70 F DB in heating. AHRI/ISO certifi ed conditions are 80.6 F DB and 66.2 F WB in cooling and 68 F DB in heating. Table does not refl ect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40 F EWT is based upon a 15% methanol antifreeze solution. Operation below 60 F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. LC386-10

11 Performance Data TRC CFM Nominal (Rated) Airflow EWT F GPM Performance capacities shown in thousands of Btuh WPD* Cooling - EAT 80/67 F Heating - EAT 70 F PSI FT TC SC Sens/Tot Ratio kw HR EER HC kw HE LAT COP Operation not recommended *WPD Adder for Motorized Valve, TRC15 (Cv = 4.9, MOPD = 150 psi) GPM WPD Adder PSI FT Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80 F DB and 67 F WB in cooling, and 70 F DB in heating. AHRI/ISO certifi ed conditions are 80.6 F DB and 66.2 F WB in cooling and 68 F DB in heating. Table does not refl ect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40 F EWT is based upon a 15% methanol antifreeze solution. Operation below 60 F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. LC386-11

12 Performance Data TRC CFM Nominal (Rated) Airflow EWT F GPM Performance capacities shown in thousands of Btuh WPD* Cooling - EAT 80/67 F Heating - EAT 70 F PSI FT TC SC Sens/ Tot Ratio kw HR EER HC kw HE LAT COP Operation not recommended *WPD Adder for Motorized Valve, TRC18 (Cv = 4.9, MOPD = 150 psi) GPM WPD Adder PSI FT Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80 F DB and 67 F WB in cooling, and 70 F DB in heating. AHRI/ISO certifi ed conditions are 80.6 F DB and 66.2 F WB in cooling and 68 F DB in heating. Table does not refl ect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40 F EWT is based upon a 15% methanol antifreeze solution. Operation below 60 F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. LC386-12

13 Performance Data Correction Tables Air Flow Correction Table Airflow Cooling Heating % of Rated Total Capacity Sensible Capacity Power Heat of Rejection Heating Capacity Power Heat of Extraction 73% % % % % % % % Entering Air Correction Tables Entering Air DB F Heating Capacity Heating Power Heat of Extraction Entering Air WB F Total Capacity Cooling Sensible Cooling Capacity Multiplier - Entering DB F Power Heat of Rejection * * * * * * * = Sensible capacity equals total capacity AHRI/ISO/ASHRAE uses entering air conditions of Cooling F DB/66.2 F WB, 1 and Heating - 68 F DB/59 F WB entering air temperature Antifreeze Correction Table Antifreeze % Cooling Heating WPD Corr. Fct. EWT 30 F Antifreeze Type EWT 90 F EWT 30 F Total Cap Sens Cap Power Htg Cap Power Water Propylene Glycol Methanol Ethanol Ethylene Glycol LC386-13

14 Blower Performance & Electrical Data Blower Performance Model Rated CFM Low Speed SCFM Medium Speed High Speed TRC TRC TRC TRC Fan speed is user selectable All airfl ow is rated at lowest Voltage if unit is dual Voltage rated, i.e. 208V for V units All units AHRI/ISO/ASHRAE rated on high fan speed All units are designed and rated for zero external static pressure (non-ducted) application Electrical Data Model TRC09 TRC12 TRC15 TRC18 Voltage Code Voltage Min/Max Voltage Compressor RLA LRA Fan Motor FLA A 115/60/ G /60/ E 265/60/ A 115/60/ G /60/ E 265/60/ G /60/ E 265/60/ G /60/ E 265/60/ Pump Option FLA Total Unit FLA Min Circuit Amps Max Fuse Amps N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A LC386-14

15 Physical Data Model Compressor (1 Each) Rotary Factory Charge HFC-410A (oz) [kg] 28 [0.794] 29 [0.822] 33 [0.907] 39 [1.105] Blower Wheel Blower Wheel Size (dia x w) - (in) [mm] - Qty x 6.25 [133 x 159] Water Connection Size O.D. Sweat (in) [mm] 1/2 [12.7] 3/4 [19.1] FPT Fittings (in) 1/2 3/4 MPT Fittings (in) 1/2 3/4 Coax Volume Volume US Gal [Liters] Condensate Connection Size.09 [.34].09 [.34].23 [.87] I.D. Vinyl Hose (In) [mm] 5/8 [15.9] Air Coil Size Dimensions (h x w) - (in) [mm] 8 x 26 [203 x 660] 10 x 26 [254 x 660].26 [.98] 10 x 32 [254 x 812] Filter Size Bottom Return (in) [mm] 1-10 x 30 x 1 [254 x 762 x 25] 1-10 x 36 x 1 [254 x 914 x 25] Front Return (In) [mm] 1-7 x 29.5 x 1/8 [178 x 749 x 3.2] 1-7 x 35.5 x 1/8 [178 x 902 x 3.2] Unit Size Bottom Return (Std. 5 Base) (W x H x D) - (In) [mm] 48 x 26 x 12 [1219 x 660 x 305] 54 x 26 x 12 [1372 x 660 x 305] Front Return (No Subbase) (W x H x D) - (In) [mm] 48 x 21 x 12 [1219 x 533 x 305] 54 x 21 x 12 [1372 x 533 x 305] Unit Weight Weight - Operating, (lbs) [kg] 175 [79] 180 [82] 190 [86.2] 220 [99.8] Weight - Packaged, (lbs) [kg] 185 [83.9] 190 [86] 200 [90.8] 232 [105.2] All units have rubber grommet compressor mountings and TXV expansion devices. Unit Maximum Water Working Pressure Options Base Unit 500 [3,445] Internal Secondary Pump (ISP) 145 [999] Internal Motorized Water Valve (MWV) 300 [2,068] Internal Auto Flow Valve 500 [3,445] Max Pressure PSIG [kpa] Use the lowest maximum pressure rating when multiple options are combined. hoses have pressure rating of 400 PSIG (2758 (kpa) Factory Installed Auto Flow Regulator GPM [LPS] Model 2.25 GPM/Ton 3 GPM/Ton [.126] 2.5 [.158] [.158] 3.0 [.189] [.189] 3.5 [.221] [.221] 4.0 [.252] LC386-15

16 Console Cabinet Dimensions Size Bottom Return - Left Hand Piping Left Hand Bottom Return F Discharge Air Grille 11.0 (279) 1.50 (38) Discharge Air 3.50 (89) 30 Filter located inside and at top of air inlet area. Rotate filter latch forward, filter rack can be pulled forward 3 to 4 for filter access. Control Access Door FRONT VIEW 3.53 (90) Removable Cabinet Sub-base SIDE VIEW (658) Fixed Back Wrapper B AIR INLET AREA C A Air Inlet (3) (292) 4.90 (125) (305) 2.12 (54) 6.88 (174) 1.75 (44) 3.00 (76) (254) Bottom Access for Piping and Electric (Note 2) 0.75 (19) BOTTOM VIEW Standard Unit Extended Unit A B C D E F (1219) 1.75 (44.5) (851) 9.90 (251) (1372) (292) (876) (582) Secondary circulation pump models will have extended unit (114) (267) 5.00 (127) (279) 1.00 (25) E 1.00 (25) (1041) REAR VIEW 1.63 (41) L.H. Rear Access For Piping and Electric (NOTE 2) (508) (533) DAMPER OPENING A (298) 0.59 (15) D 4.90 (125) Notes: 1. All Dimensions are in inches (mm). 2. Access is reduced if optional disconnect box is selected. 3. autoflow regulator, motorized water valve, and disconnect box are not shown. 4. Filter is 1 (25) thick fiberglass throwaway. Rev.: 10/03/08B LC386-16

17 Console Cabinet Dimensions Size Front Return - Left Hand Piping Left Hand Front Return C Discharge Air Grille (279) 1.50 (38) 3.50 (89) (533) 7.90 (201) A (1110) (305) Removable Cabinet Fixed Back Wrapper.50 (13) A B C D (292) Standard Unit Extended Unit (1219) 4.50 (114) (1372) (267) 5.00 (127) 4.12 (105) (279) (257).75 (19) D Bottom Access for Piping and Electric (Note 2) B Secondary circulation pump models will 1.00 have extended unit. (25) 1.00 (25) L.H. Rear Access for Piping and Electric (NOTE 2) (533) (1041) A Notes: 1. All Dimensions are in inches (mm). 2. Access is reduced if optional disconnect box is selected. 3. autoflow regulator, motorized water valve, and disconnect box are not shown. 4. Filter is a cleanable polypropylene mesh. LC386-17

18 Console Cabinet Dimensions Size Bottom Return - Right Hand Piping Right Hand Bottom Return 1.50 (38) Discharge Air Grille Filter located inside and at top of air inlet area. Rotate filter latch forward, filter rack can be pulled forward 3 to 4 for filter access Control Access Door FRONT VIEW (279) F Discharge Air 30 Removable Cabinet Sub-base SIDE VIEW 3.50 (89) (658) Fixed Back Wrapper 3.53 (90) B AIR INLET AREA C A.12 (3) Air Inlet (292) (125) (305) BOTTOM VIEW (254) 6.88 (174) Bottom Access for Piping and Electric (Note 2) 2.12 (54) 1.00 (25) 1.00 (25) E.75 (19) 3.00 (76) 1.75 (44) Standard Unit Extended Unit A B C D E F (1219) (44.5) (851) (251) (114) (127) (1372) (44.5) (856) (326) (267) (279) Secondary circulation pump models will have extended unit. R.H. Rear Access for Piping and Electric (Note 2) REAR VIEW 1.63 (41) (1041) (533) A DAMPER OPENING (298) 0.59 (15) D 4.90 (125) Notes: 1. All Dimensions are in inches (mm). 2. Access is reduced if optional disconnect box is selected. 3. autoflow regulator, motorized water valve, and disconnect box are not shown. 4. Filter is 1 (25) thick fiberglass throwaway. LC386-18

19 Console Cabinet Dimensions Size Front Return - Right Hand Piping Right Hand Front Return 1.50 (38) Discharge Air Grille 11.0 (279) C Discharge Air 3.50 (89) 30 Control Access Door FRONT VIEW SIDE VIEW (533) 7.90 (201) Air Inlet A (1110) Filter located behind return air grille and requires removal of cabinet front for access. Removable Cabinet (305) Fixed Back Wrapper (305) 1.00 (25) B BOTTOM VIEW D (292).75 (19).50 (13) Bottom Access for Piping and Electric Standard Unit A B C D (1219) 4.50 (114) Extended Unit (1372) (267) Secondary circulation pump models will have extended unit (127) 4.12 (105) (279) (257) 1.00 (25) R.H. Rear Access for Piping and Electric (Note 2) REAR VIEW (1041) (533) A Notes: 1. All dimensions are in inches (mm). 2. Access is reduced if optional disconnect box is selected 3. autoflow regulator, motorized water valve, and disconnect box are not shown. 4. Filter is a cleanable polypropylene mesh. LC386-19

20 Console Bottom Return Chassis Dimensions Size *20.50 (521) 0.75 (19) Power Termination (D,H,K) Box (mounted to cabinet not chassis) Power supply enters Bottom of Box (1040) Hard Wire Power Supply 5.36 (136) 3.01 (76) Control Box (22) Blower Deck Blower Access Panel Compressor Access Panel 4.25 (108) *16.66 (423) 5.12 (130) *3.56 (90) (762) 0.75 (19) Right Hand Configuration (Bottom Return) (293) 3.62 (92) 3.01 (76) 5.36 (136) Power Supply (1041) Autoflow Valve 0.87 (22) 30 Motorized Water Valve 3.62 (92) *16.66 (423) Blower Deck 5.12 (130) *3.56 (90) (293) 4.25 (108) 0.75 (19) Blower Access Panel (762) Left Hand Configuration (Bottom Return) Notes: All Dimensions are in inches (mm) * If subbase option is selected for installed dimension, add to dimension shown 4.90" [124mm] for 5" subbase, or dimension unit is raised above floor (4.90 [124] minimum) autoflow valve, motorized water valve and disconnect box are shown. Option to order subbase (not shown) Autoflow Valve Motorized Water Valve 4.56 (116) 4.25 (108) Control Box Compressor Access Panel 0.75 (19) Power Termination (D,H,K) Box (mounted to cabinet not chassis) Power supply enters Bottom of Box Disconnect (F) Only Box (All Configurations) Power supply enters Bottom of Box Note: Box may be 2 x 4 junction box with switch facing front or side. *20.50 (521) LC386-20

21 Console Front Return Chassis Dimensions Size (521) 0.75 (19) Power Termination (D, H, K) Breaker Box (mounted to cabinet not chassis) Power supply enters Bottom of Box Blower Deck Filter (762) (1040) Hard Wire Power Supply 5.36 (136) 3.01 (76) Control Box 0.87 (22) 30 Blower Screen 7.38 (187) Compressor Access Panel 4.25 (108) 0.75 (19) (423) Right Hand Configuration (Front Return) (293) 3.62 (92) 5.12 (130) 3.56 (90) Autoflow Valve Motorized Water Valve 3.01 (76) 5.36 (136) Power Supply (1040) Autoflow Valve 0.87 (22) 30 Motorized Water Valve 3.62 (92) (423) Blower Deck 5.12 (130) 3.56 (90) 4.25 (108) Filter (293) Left Hand Configuration (Front Return) 0.75 (19) (762) Blower Screen Notes: All Dimensions are in inches (mm) Chassis can mount directly on floor autoflow valve, motorized water valve and disconnect box are shown. Power Termination (D, H, K) Breaker Box (mounted to cabinet not chassis) Power supply enters Bottom of Box Disconnect (F) Only Box (All Configurations) Power supply enters Bottom of Box 4.56 (116) 4.25 (108) Note: Box may be 2 x 4 junction box with switch facing front or side. Control Box 7.38 (187) Compressor Access Panel (521) 0.75 (19) Rev.: 08/12/14J LC386-21

22 Piping Detail Size (41) 2.00 (51) 8.00 Min (203) *11.25 (286) 2.25 (57) 1.75 (44) 1.84 (47) Right Hand Configuration 2.25 (57) *11.25 (286) 2.00 (51) 1.50 (38) 2.25 (57) 8.00 Min (203) 2.72 (96) Left Hand Configuration LC386-22

23 Console Cabinet Dimensions Size 18 - Bottom Return - Left Hand Piping Left Hand Bottom Return F Discharge Air Grille (279) 1.50 (38) Discharge Air 3.50 (89) Filter located inside and at top of air inlet area. Rotate filter latch forward, filter rack can be pulled forward 3 to 4 for filter access Control Access Door FRONT VIEW Removable Cabinet Sub-base SIDE VIEW (658) Fixed Back Wrapper 3.53 (90) B AIR INLET AREA C A.12 (3) Air Inlet (292) 4.90 (125) (305) 2.12 (54) 6.88 (174) (254) 0.75 (19) BOTTOM VIEW Standard Unit Extended Unit A B C D E F (1372) (44.5) (1010) (403) (114) (127) (1524) (294) (908) (632) (267) (279) 1.75 (44) 3.00 (76) Bottom Access for Piping and Electric (Note 2) E 1.00 (25) 1.00 (25) Secondary circulation pump models will have extended unit. REAR VIEW 1.63 (41) (1193) L.H. Rear Access for Piping and Electric (Note 2) (533) DAMPER OPENING A (298) 0.59 (15) D 4.90 (125) Notes: 1. All Dimensions are in inches (mm). 2. Access is reduced if optional disconnect box is selected. 3. autoflow regulator, motorized water valve, and disconnect box are not shown. 4. Filter is 1 (25) thick fiberglass throwaway. LC386-23

24 Console Cabinet Dimensions Size 18 - Front Return - Left Hand Piping Left Hand Front Return C Discharge Air Grille (279) 1.50 (38.1) Discharge Air 3.50 (89) Control Access Door (533) FRONT VIEW 7.90 (201) Air Inlet SIDE VIEW (533).50 (13) (1219) A Filter located behind return air grille and requires removal of cabinet front for access (305) Removable Cabinet Fixed Back Wrapper (292) BOTTOM VIEW Standard Unit Extended Unit A B C D (1372) (114) (127) (105) (1524) (267) (279) (257).75 (19) D Bottom Access for Piping and Electric (Note 2) 1.00 (25) Secondary circulation pump models will have extended unit. B 1.00 (25) REAR VIEW (1193) L.H. Rear Access for Piping and Electric (Note 2) (533) A Notes: 1. All Dimensions are in inches (mm). 2. Access is reduced if optional disconnect box is selected. 3. autoflow regulator, motorized water valve, and disconnect box are not shown. 4. Filter is a cleanable polypropylene mesh. LC386-24

25 Console Cabinet Dimensions Size 18 - Bottom Return - Right Hand Piping Right Hand Bottom Return Discharge Air Grille (279) F Discharge Air 3.50 (89) Filter located inside and at top of air inlet area. Rotate filter latch forward, filter rack can be pulled forward 3 to 4 for filter access. Control Access Door FRONT VIEW Removable Cabinet SIDE VIEW (658) Fixed Back Wrapper 3.53 (90) Sub-base B AIR INLET AREA C A.12 (3) Air Inlet (292) 4.90 (125) (305) Bottom Access for Piping and Electric (Note 2) BOTTOM VIEW (254) 6.88 (174) 2.12 (54) 1.00 (25) 1.00 (25) E 3.00 (76) 0.75 (19) 1.75 (44) Standard Unit Extended Unit A B C D E F (1372) (44.5) (1010) (403) (114) (127) (1524) (44.5) (908) (356) (267) (279) Secondary circulation pump models will have extended unit. RH Rear Access for Piping and Electric (Note2) REAR VIEW 1.63 (41) (533) A DAMPER OPENING (298) 0.59 (15) D 4.90 (125) Notes: 1. All Dimensions are in inches (mm). 2. Access is reduced if optional disconnect box is selected. 3. autoflow regulator, motorized water valve, and disconnect box are not shown. 4. Filter is 1 (25) thick fiberglass throwaway. LC386-25

26 Console Chassis Dimensions Size 18 - Front Return - Right Hand Piping Right Hand Front Return 1.50 (38) Discharge Air Grille (279) C Discharge Air 3.50 (89) Control Access Door (533) FRONT VIEW 7.90 (201) Air Inlet SIDE VIEW (533) A (1219) Filter located behind return air grille and requires removal of cabinet front for access..50 (13) (305) Removable Cabinet Fixed Back Wrapper (305) BOTTOM VIEW (292) Bottom Access for Piping and Electric (Note 2) Standard Unit Extended Unit A B C D (1372) (114) (127) (105) (1524) (267) (279) (257) 1.00(25) B D.75 (19) Secondary circulation pump models will have extended unit. 1.00(25) RH Rear Access for Piping and Electric (Note 2) REAR VIEW (1193) (533) A Notes: 1. All Dimensions are in inches (mm). 2. Access is reduced if optional disconnect box is selected. 3. autoflow regulator, motorized water valve, and disconnect box are not shown. 4. Filter is a cleanable polypropylene mesh. LC386-26

27 Console Bottom Return Chassis Dimensions Size 18 *20.50 (521) 0.75 (19) Power Termination (D, H, K) Breaker Box (mounted to cabinet not chassis) Power supply enters Bottom of Box (1193) Hard Wire Power Supply (136) 3.01 (76) Control Box 0.87 (22) Blower Deck Blower Access Panel Compressor Access Panel *16.66 (423) 5.12 (130) (914) 4.25 (108) 0.75 (19) Condensate 5/8" ID V inyl Hose (15.8mm) (293) 3.62 (92) *3.56 (90) Right Hand Configuration (Bottom Return) Autoflow Valve Motorized Water Valve 0.87 (22) 3.01 (76) 5.36 (136) Hard Wire Power Supply Motorized Water Valve Autoflow Valve 3.62 (92) *16.66 (423) 5.12 (130) *3.56 (90) 4.25 (108) (293) Condensate 5/8" ID Vinyl Hose Notes: All Dimensions are in inches (mm) * For installed dimension, add to dimension shown 4.9" [124mm] for 5" subbase. autoflow valve, motorized water valve and disconnect box are shown. Option to order subbase (not shown) Left Hand Configuration (Bottom Return) 0.75 (19) Autoflow Valve Motorized Water Valve (1193) Blower Deck Blower Access Panel (914) Rev.: 10/07/08B 4.56 (116) 4.25 (108) Power Termination (D, H, K) Breaker Box (mounted to cabinet not chassis) Power supply enters Bottom of Box Disconnect (F) Only Box (All Configurations) Power supply enters Bottom of Box Note: Box may be 2 x 4 junction box with switch facing front or side. Control Box Compressor Access Panel *20.50 (521) 0.75 (19) LC386-27

28 Console Chassis Dimensions Size (521) 0.75 (19) Power Termination (D, H, K) Breaker Box (mounted to cabinet not chassis) Power supply enters Bottom of Box Blower Deck Filter (914) (1193) Hard Wire Power Supply 5.36 (136) 3.01 (76) Control Box 0.87 (22) 30 Blower Screen 7.38 (187) Compressor Access Panel 4.25 (108) 0.75 (19) (423) Right Hand Configuration (Front Return) (293) 3.62 (92) 5.12 (130) 3.56 (90) Autoflow Valve Motorized Water Valve 3.01 (76) 5.36 (136) Power Supply (1193) Autoflow Valve 0.87 (22) 30 Motorized Water Valve 3.62 (92) (423) Blower Deck 5.12 (130) 3.56 (90) 4.25 (108) Filter (293) Left Hand Configuration (Front Return) 0.75 (19) (914) Blower Screen Notes: All Dimensions are in inches (mm) Chassis can mount directly on floor autoflow valve, motorized water valve and disconnect box are shown. Power Termination (D, H, K) Breaker Box (mounted to cabinet not chassis) Power supply enters Bottom of Box Disconnect (F) Only Box (All Configurations) Power supply enters Bottom of Box 4.56 (116) 4.25 (108) Note: Box may be 2 x 4 junction box with switch facing front or side. Control Box 7.38 (187) Compressor Access Panel (521) 0.75 (19) Rev.: 08/12/14J LC386-28

29 Piping Detail Size (44) Control Box Compressor Access Panel 1.50 (38) Water In Water Out 8.00 Min (203) Motorized Water Valve Water Connections 7/8 (22.2) OD Copper, 3/4 IPT, or 3/4 EPT *11.12 (282) 1.75 (44) 1.84 (47) Auto Flow Valve 2.12 (54) Out In Condensate 5/8" (15.9) ID Vinyl Hose Right Hand Configuration Autoflow Valve Motorized Water Valve Water Connections.875 (22.2mm) OD Copper, 3/4" IPT or 3/4" EPT Fused Disconnect Box (mounted to cabinet not chassis) Also Available in Non-Fused Autoflow Valve ns Out In Water Connections 7/8 (22.2) OD Copper, 3/4 IPT, or 3/4 EPT 2.12 (54) Autoflow Valve Motorized Water Valve *11.12 (282) 2.25 (286) Water In 1.50 (38) 8.00 Min (203) 1.75 (44) Water Out Blower Deck Blower Access Panel Control Box Compressor Access Panel (52) Condensate 5/8" (15.9) ID Vinyl Hose 2.72 (96) Left Hand Configuration 0.75 (19) Notes: * Dimension reduced by fitting if selected LC386-29

Tranquility Vertical Stack (TSL) Series

Tranquility Vertical Stack (TSL) Series Tranquility Vertical Stack (TSL) Series Submittal Data Models TSL09-36 60Hz - HFC-410A English Language/I-P Units SUBMITTAL DATA - I-P UNITS Unit Designation: Job Name: Architect: Engineer: Contractor:

More information

VERTICAL STACK (VHS) SERIES

VERTICAL STACK (VHS) SERIES VERTICAL STACK () SERIES SIZE 10-36 (2.6kW - 10.6kW) VERTICAL HI-RISE R22-60Hz STANDARD RANGE R22-60Hz STANDARD SIZE 10-36 (2.6kW - 10.6kW) VERTICAL HI-RISE VERTICAL STACK () SERIES THE SMART SOLUTION

More information

Tranquility 30 Two-Stage (TT) Series

Tranquility 30 Two-Stage (TT) Series Tranquility 30 Two-Stage (TT) Series Submittal Data Models TT/H/V 026-072 60Hz - HFC-410A *LC1020* LC1020 Rev.: November 18, 2016 Table of Contents Two- Stage TT Series Unit Features 3 Selection Procedure

More information

Tranquility Vertical Stack (TSM) Series

Tranquility Vertical Stack (TSM) Series Tranquility Vertical Stack (TSM) Series Submittal Data Models TSM09-36 60Hz - HFC-410A English Language/I-P Units SUBMITTAL DATA - I-P UNITS Unit Designation: Job Name: Architect: Engineer: Contractor:

More information

Tranquility Vertical Stack (TSM) Series Submittal Data

Tranquility Vertical Stack (TSM) Series Submittal Data Tranquility Vertical Stack (TSM) Series Submittal Data Models TSM09-36, 60Hz - HFC-410A *LC994* LC994 Rev.: September 26, 2018 ClimateMaster works continually to improve its products. As a result, the

More information

Tranquility 22 Compact Ultra Efficiency (TY) Series Submittal Data

Tranquility 22 Compact Ultra Efficiency (TY) Series Submittal Data Tranquility 22 Compact Ultra Efficiency (TY) Series Submittal Data Models TYH/V024-060 60Hz - HFC-410A *LC992* LC992 Rev.: November 27, 2018 Table of Contents TY Compact Ultra Efficiency Series Unit Features

More information

THE SMART SOLUTION FOR ENERGY EFFICIENCY ENGINEERING DESIGN GUIDE: CONSOLE (CCE) SERIES 0.5 TO 1.5 TON CONSOLE UNITS WATER-SOURCE HEAT PUMP SYSTEMS

THE SMART SOLUTION FOR ENERGY EFFICIENCY ENGINEERING DESIGN GUIDE: CONSOLE (CCE) SERIES 0.5 TO 1.5 TON CONSOLE UNITS WATER-SOURCE HEAT PUMP SYSTEMS THE SMART SOLUTION FOR ENERGY EFFICIENCY ENGINEERING DESIGN GUIDE: CONSOLE (CCE) SERIES 0.5 TO 1.5 TON CONSOLE UNITS WATER-SOURCE HEAT PUMP SYSTEMS The Smart Choice for Energy Efficiency TABLE OF CONTENTS

More information

HEAT CONTROLLER, INC. HSS Series 1 1/2 to 5 Tons Indoor Split System Geothermal Heat Pumps

HEAT CONTROLLER, INC. HSS Series 1 1/2 to 5 Tons Indoor Split System Geothermal Heat Pumps HEAT CONTROLLER, INC. ENGINEERING DESIGN GUIDE HSS Series 1 1/2 to 5 Tons Indoor Split System Geothermal Heat Pumps HEAT CONTROLLER, INC. 1900 Wellworth Ave., Jackson, Michigan 49203 Ph. 517-787-2100 Fax

More information

*20D082-05NN* 20D082-05NN

*20D082-05NN* 20D082-05NN 2506 South Elm Street Greenville, IL 62246 www.enertechgeo.com info@enertechmfg.com HT Models Packaged Water-to-Air Horizontal Heat Pumps Engineering Data and Installation Manual Rev.: 25 May 2012D P/N:

More information

THE TRANQUILITY 16 COMPACT (TC) SERIES

THE TRANQUILITY 16 COMPACT (TC) SERIES The Tranquility 16 Compact (TC) Series raises the bar for water-source heat pump effi ciencies, features and application fl exibility. Not only does the Tranquility 16 Compact Series exceed ASHRAE 90.1

More information

ENGINEERING DESIGN GUIDE: GENESIS COMPACT (GC) SERIES 0.5 TO 5 TON HORIZONTAL AND VERTICAL UNITS

ENGINEERING DESIGN GUIDE: GENESIS COMPACT (GC) SERIES 0.5 TO 5 TON HORIZONTAL AND VERTICAL UNITS THE SMART SOLUTION FOR ENERGY EFFICIENCY ENGINEERING DESIGN GUIDE: GENESIS COMPACT (GC) SERIES 0.5 TO 5 TON HORIZONTAL AND VERTICAL UNITS WATER-SOURCE HEAT PUMP SYSTEMS The Smart Choice for Energy Efficiency

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Compact, Self-Contained unit that offer low installation cost plus dependable performance. 0 Compact, Self-Contained unit that offer low installation cost plus dependable performance. From carrier s excellence in engineering come a new, compact of single package horizontal and vertical water

More information

Commercial and Residential Water Source Heat Pumps Boiler/Tower and Geothermal Applications

Commercial and Residential Water Source Heat Pumps Boiler/Tower and Geothermal Applications Commercial and Residential Water Source Heat Pumps Boiler/Tower and Geothermal Applications SOLUTION 1 WATER-SOURCE HEAT PUMPS Water-Loop heat pump systems combine water-source heat pumps on a common piping

More information

ENGINEERING DESIGN GUIDE: GENESIS STANDARD (GR) SERIES 0.5 TO 5 TON HORIZONTAL AND VERTICAL UNITS

ENGINEERING DESIGN GUIDE: GENESIS STANDARD (GR) SERIES 0.5 TO 5 TON HORIZONTAL AND VERTICAL UNITS THE SMART SOLUTION FOR ENERGY EFFICIENCY ENGINEERING DESIGN GUIDE: GENESIS STANDARD (GR) SERIES 0.5 TO 5 TON HORIZONTAL AND VERTICAL UNITS WATER-SOURCE HEAT PUMP SYSTEMS The Smart Choice for Energy Efficiency

More information

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000

More information

Product Data. Single-Package Horizontally Mounted Water Source Heat Pumps with Electronic

Product Data. Single-Package Horizontally Mounted Water Source Heat Pumps with Electronic Product Data Aquazone 0RHE006-060 Water Source Heat Pumps Horizontal Unit 0 Hz, CE Mark R-407C 1.to13.7NominalkW(Cooling) 1.8 to 16. 8 Nominal kw (Heating) TM Copyright 2004 Carrier Corporation Single-Package

More information

Product Data. AQUAZONE 50HQP Large Capacity Horizontal Water Source Heat Pumps with PURON Refrigerant (R-410A) 6 to 10 Nominal Tons

Product Data. AQUAZONE 50HQP Large Capacity Horizontal Water Source Heat Pumps with PURON Refrigerant (R-410A) 6 to 10 Nominal Tons Product Data AQUAZONE 50HQP072-120 Large Capacity Horizontal Water Source Heat Pumps with PURON Refrigerant (R-410A) 6 to 10 Nominal Tons TM Single-package horizontally mounted water source heat pumps

More information

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons Product Data OMNIZONE 50BRN,BZN006-024 Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems 5 to 20 Nominal Tons The 50BRN,BZN water-cooled and remote air-cooled indoor, self-contained units

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

Product Data. Features/Benefits. AQUAZONE 50PCH,PCV Compact Water Source Heat Pumps with PURON Refrigerant (R-410A) 50 Hz

Product Data. Features/Benefits. AQUAZONE 50PCH,PCV Compact Water Source Heat Pumps with PURON Refrigerant (R-410A) 50 Hz Product Data AQUAZONE 50PCH,PCV009-060 Compact Water Source Heat Pumps with PURON Refrigerant (R-410A) 50 Hz 2.1 to 15.0 Nominal kw Single-package horizontally and vertically mounted water source heat

More information

Genesis Compact (GC) Series Submittal Data

Genesis Compact (GC) Series Submittal Data SERIES: HZ: UNIT OF MEAS: LANGUAGE: GC - R22 50 SI ENGLISH Genesis Compact (GC) Series Submittal Data Models GCH/V 018B - 060B 50Hz - R22 English Language/SI Units REVISION: 03/13/03 ** MODEL DECODER GC

More information

GEOTHERMAL SPLIT SYSTEMS CLIMATEMASTER

GEOTHERMAL SPLIT SYSTEMS CLIMATEMASTER GEOTHERMAL SPLIT SYSTEMS CLIMATEMASTER INDOOR & OUTDOOR SPLIT GEOTHERMAL HEATING AND COOLING COMFORT SYSTEMS TRANQUILITY 27 INDOOR SPLIT (TTS) SERIES - SIZES 026-064 GENESIS INDOOR SPLIT (GSS) SERIES -

More information

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

ENGINEERING DESIGN GUIDE: TRANQUILITY 27 TWO-STAGE (TT) SERIES 2 TO 5.5 TON HORIZONTAL AND VERTICAL EARTHPURE UNITS

ENGINEERING DESIGN GUIDE: TRANQUILITY 27 TWO-STAGE (TT) SERIES 2 TO 5.5 TON HORIZONTAL AND VERTICAL EARTHPURE UNITS THE SMART SOLUTION FOR ENERGY EFFICIENCY ENGINEERING DESIGN GUIDE: TRANQUILITY 27 TWO-STAGE (TT) SERIES 2 TO 5.5 TON HORIZONTAL AND VERTICAL EARTHPURE UNITS WATER-SOURCE HEAT PUMP SYSTEMS The Smart Choice

More information

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are

More information

SpaceKeeper Console (SKC)

SpaceKeeper Console (SKC) SpaceKeeper Console (SKC) With finished cabinet or custom enclosure SKC 008-015 ¾ - 1¼ tons 12 W x 25¼ H x 48 L CGC-09 SpaceKeeper Console R410A MODEL NO. SKC _ 008 010 012 015 Net Cooling Capacity - Rated

More information

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal

More information

GT-PW (50YEW) Water-To-Water Series. WATER-TO-WATER PURON SYSTEMS SIZE 010 [10 kw]

GT-PW (50YEW) Water-To-Water Series. WATER-TO-WATER PURON SYSTEMS SIZE 010 [10 kw] GT-PW () Water-To-Water Series WATER-TO-WATER PURON SYSTEMS SIZE 010 [10 kw] Revised May 8, 2013 GT-PW Water-to-Water () Series Table of Contents Unit Features...3 Model Key...5 Rated Equipment Performance

More information

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal

More information

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal

More information

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 18,000

More information

June PRODUCT DESIGN GUIDE Whisperline Console

June PRODUCT DESIGN GUIDE Whisperline Console June 2018 PRODUCT DESIGN GUIDE Whisperline Console Table of Contents Console Unit Nomenclature 1 AHRI Performance Rating 3 Unit Protection & LED Fault Status 5 Unit Mounted Control 6 Physical Data Table

More information

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece

More information

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON 7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

GUIDE SPECIFICATIONS AQUARIUS ii

GUIDE SPECIFICATIONS AQUARIUS ii Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Heat Pump, Ground Water

More information

FCC Fan-Coil Units High-Performance, Vertical

FCC Fan-Coil Units High-Performance, Vertical FCC Fan-Coil s High-Performance, Vertical Model FCC construction features Piping and supply-duct connections are from top of unit, eliminating the need for side or back access Right or left-hand configurations

More information

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series 1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor

More information

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil A13303 Fig. 1 - FPM(A,B)NU Uncased Horizontal Fan Coil (FPMANU model shown) Fig. 2 - FPM(A,B)NC Cased Horizontal Fan Coil

More information

MAC-120HE-03 Air-Cooled Chiller

MAC-120HE-03 Air-Cooled Chiller MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

VertiCool Aurora Engineering Guide

VertiCool Aurora Engineering Guide Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8

More information

PAR5. Product Specifications

PAR5. Product Specifications TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced

More information

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil MHCFC4W-16-01 Chilled/Hot Water Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.1 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 48,000 BTUH Multiaqua

More information

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil MHCFC4W-04-01 Chilled/Hot Water Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 12,000 BTUH Multiaqua

More information

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil MHCFC4W-08-01 Chilled/Hot Water Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.1 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING SOUND REFRIGERANT ENVIRONMENTALLY PAN5 Product Specifications 15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R--410A refrigerant

More information

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS Product Data FF1DNA, FF1DNE Fan Coil Units Sizes 018 thru 030 FF1D FEATURES/BENEFITS The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air

More information

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230

More information

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed

More information

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled FORM 145.05-EG1 (1004) VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU 10 105 Ton Water-Cooled Table of Contents FORM 145.05-EG1 (0804) Features and Benefits.....................................................

More information

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons Product Data 50JS Single-Packaged Heat Pump Units 1 1/2 to 5 Nominal Tons UNIT 50JS (STANDARD) Single-Packaged Heat Pump for Residential and Light Commercial Applications Low Sound Levels 10 SEER Features/Benefits

More information

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes )

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes ) Single---Packaged Air Conditioner tem With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes 024---060) Product Data Unit A10165 The unit is a packaged air conditioner for manufactured housing,

More information

Tranquility Console (TRC) Series

Tranquility Console (TRC) Series Tranquility Console (TRC) Series Commercial Console WaterSource Heat Pumps 50Hz & 60Hz Installation, Operation & Maintenance 97B0035N01 Revised: 5 February, 2016 Table of Contents Model Nomenclature: Tranquility

More information

Product Data. Fig. 1 - Unit 50VG -A

Product Data. Fig. 1 - Unit 50VG -A 50VG---A Performancet 16 SEER 2---Stage Packaged Air Conditioner tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VG -A A09033 Single-Packaged

More information

WPH4 Product Specifications

WPH4 Product Specifications Up to 14.5 SEER, 8.0 HSPF PACKAGE HEAT PUMP 2 to 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification

More information

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 Product Data A10097 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 60,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230

More information

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Fig. 1 - Unit 50VR -A 50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged

More information

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons 007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),

More information

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR: 2 -speed

More information

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS ENGINEERING SPECIFICATIONS RH-24-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 24 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.

More information

technical guide Water-Cooled Self-Contained Units

technical guide Water-Cooled Self-Contained Units technical guide Water-Cooled Self-Contained Units C-Series, Vertical Technical Guide: YK145.00-EG3 (710) TABLE OF CONTENTS Water-Cooled Self-Contained Units Introduction...............................................................................

More information

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts GTIP60 ISO GT Series, Inch Pounds 60 Hz GT010070 (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts Rev: 903 Rev 1 Revisions: 31103 Changed HZ dwg to field convertible 5902 changed Unit

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS ENGINEERING SPECIFICATIONS RH-12-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 12 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.

More information

50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron

50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron 50VT---C Comfortt 14 SEER Single---Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single Phase 2 --- 5 Nominal Tons (Sizes 24 --- 60) Three Phase 3 --- 5 Nominal Tons (Sizes 36 --- 60) Product

More information

Applied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat

Applied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat Applied Packaged Terminal Air Conditioner with Catalog 1355-9 Top-Mounted Hydronic Heat 16" 42" Model PDAN Unit Sizes 007 017 R-410A Refrigerant Engineered for flexibility and performance Unit Features

More information

McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995

McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995 Replacement Parts List No. 055236000 Revision B 06/2015 McQuay Ceiling Concealed Horizontal Water Source Heat Pump CCH, CCG, CCW 048, 060 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts

More information

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons 0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can

More information

C13-Series Engineering Guide

C13-Series Engineering Guide Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps Product Data OMNIZONE 50BV020-064 Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps 18 to 60 Nominal Tons omnizonebwlogo 50BVC,E,J,K,Q020-034 SINGLE PIECE OMNIZONE

More information

ClimaDry II. Table of Contents. ClimaDry II Whole House Dehumidification Option. Tranquility 30 Tranquility 20

ClimaDry II. Table of Contents. ClimaDry II Whole House Dehumidification Option. Tranquility 30 Tranquility 20 ClimaDry II ClimaDry II Whole House Dehumidification Option Tranquility 30 Tranquility 20 Applications Guide 97B0051N01 Revision: 10 Feb., 2016 Table of Contents Model Nomenclature Example 3 ClimaDry Overview

More information

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016 Replacement Parts List No. 057117300 Revision D 08/2016 AAF Water Source Heat Pump Ceiling Mounted CCW 019-060 Vintage E Last Manufactured: 1999 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A

GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step- Heat Pump R-410A Ground Water Application: Water Temp 45 to 75 Ground Loop Application: Temp Range to 110 The Bard GEOTEC Geothermal/Water

More information

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons Product Data 50HX High Efficiency Single-Packaged Heat Pumps 2 to 5 Nominal Tons UNIT 50HX High Efficiency, Single-Packaged Heat Pump for Manufactured Housing and Residential use. Features/Benefits One-piece

More information

Engineered for flexibility and performance

Engineered for flexibility and performance Enfinity Large Vertical Water Source Heat Pumps with R-410A Refrigerant Vertical Models LVC Standard Range & LVW Geothermal Range Unit Sizes 072 290 (6 to 25 Tons) R-410A Refrigerant Catalog 1109-5 Engineered

More information

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton EP Water Source Heat Pump ½ to 6 Ton Industry-leading single-stage efficiencies, standard features, and a variety of options - providing energy efficient solutions to accommodate your building requirements.

More information

DXair Pool Dehumidifiers

DXair Pool Dehumidifiers DXair Pool Dehumidifiers LV Series / to 6 Ton G-60 Galvanized The option-rich DXair LV Series pool dehumidifier has one of the smallest cabinets in the industry, making it a great choice for replacement

More information

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES )

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES ) SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data Unit A10165 This unit is a packaged air conditioner for manufactured

More information

607C- -A PREFERREDt SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONR (R-410A) REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60)

607C- -A PREFERREDt SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONR (R-410A) REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60) 607C- -A PREFERREDt SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONR (R-410A) REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60) Product Data A09033 Fig. 1 - Unit 607C - -A Single-Packaged Products

More information

CA Model Water Source Heat Pump

CA Model Water Source Heat Pump CA Model Water Source Heat Pump ¾ to ½ ton boschheatingandcooling.com andcoo i g.c om The CA console provides high performing heating and cooling in a compact size when space and access is at a premium.

More information

Product Data. Fig. 1 - Unit 50EZ -A

Product Data. Fig. 1 - Unit 50EZ -A 50EZ---A Comfortt 13 SEER Single---Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50EZ -A A09034 Single-Packaged

More information

Product Data. Fig. 1 - Unit 50EZ -A

Product Data. Fig. 1 - Unit 50EZ -A 50EZ---A Comfortt Single---Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single --- And Three ---Phase Units 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50EZ -A A09034 Single-Packaged

More information

WJH4 Product Specifications

WJH4 Product Specifications UP TO 14.5 SEER, R 410A PACKAGE HEAT PUMP FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a

More information

DH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS. OPTIONAL ACCESSORIES Two Row Hot Water Coil

DH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS. OPTIONAL ACCESSORIES Two Row Hot Water Coil DH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS OPTIONAL ACCESSORIES Two Row Hot Water Coil MAGIC AIRE DH SERIES FAN COILS ARE ETL LISTED TO U.S. AND CANADIAN SAFETY STANDARDS AND ARE ASSEMBLED

More information

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006 Product Data FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant Sizes 002 thru 006 A02332 Premium Environmentally Sound Fan Coil The latest in technology makes the FV4B the most advanced air

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

Models PF1A PF1B PACKAGED AIR-HANDLING UNITS. 6to10Tons. Form No. PDS PF1A.72.1 FEATURES/BENEFITS

Models PF1A PF1B PACKAGED AIR-HANDLING UNITS. 6to10Tons. Form No. PDS PF1A.72.1 FEATURES/BENEFITS PACKAGED AIR-HANDLING UNITS Models PF1A PF1B 6to10Tons PF1A072-120 PF1B090 FEATURES/BENEFITS Multi-position design can be installed horizontally or vertically without modification Standard sloped drain

More information

Concealed Ducted Split Series R-407C MBH

Concealed Ducted Split Series R-407C MBH Concealed Ducted Split Series R-407C 4-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION NOMENCLATURE UNIT RATING SUMMARY

More information

COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 20 TONS

COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 20 TONS Product Specifications COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER S, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without modification.

More information

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307 DESCRIPTION Technical Guide CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) This 20 ton evaporator blower is designed with two distinct modules to provide maximum application

More information

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( )

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( ) 13 SEER Single--Packaged Heat Pump tem with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons (024--060) Product Data Fig. 1 - Unit Single -Packaged Heat Pump Units with: S easy installation

More information