1 Tel: Fax: TOSHIBA Heronhill - for all your Toshiba requirements FILE NO. A90-00 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE, HEAT PUMP COOLING ONLY WAY CASSETTE TYPE RAV-0TUH--PE RAV-TUH--PE/RAV-AH-PE RAV-TUH--PE/RAV-AH-PE RAV-TU--PE/RAV-A-PE RAV-TU--PE/RAV-A-PE Printed in UK NOVEMBER 000

2 Tel: Fax: Heronhill - for all your Toshiba requirements CONTENTS. SPECIFICATIONS. CONSTRUCTIONS VIEWS. WIRING DIAGRAMS 9. SPECIFICATIONS OF ELECTRICAL PARTS. REFRIGERANT PIPING DIAGRAMS 8. PERFORMANCE CHARACTERISTICS. EXPLODED VIEWS AND PARTS LISTS SUMMARY The units referred to within this Manual conform with the protection requirements of Directives 89//EEC Electromagnetic Compatibility and //EEC Low Voltage. Operating conditions of units are as follows: OUTDOOR TEMPERATURE - to C (COOL) -0 to C (HEAT) ROOM TEMPERATURE 8 to C (COOL) to 9 C (HEAT) ROOM HUMIDITY LESS THAN 80% (COOL) Note : Note : Note : Note : Cooling Capacity is based on the following temperature conditions: Indoor air inlet temperature C DB, 9 C WB. Outdoor air inlet temperature C DB. Heating Capacity is based on the following temperature conditions: Indoor air inlet temperature 0 C DB. Outdoor air inlet temperature C DB, C WB. For details on Control Circuits, refer to Service Manual A Metric/Imperial pipe conversion: Diameter () Nominal Diameter (inch) / /8 / /8 / /8

3 Tel: Fax: SPECIFICATIONS Item Model RAV-0TUH--PE Cooling capacity Heating capacity Power source Power consumption Power factor Running current Starting current Operating noise (SPL) Refrigerant Interconnection pipe Condensate drain pipe diameter Appearance colour Dimensions Net weight Heat exchanger type Indoor fan type Air volume Fan motor output Ceiling Panel Model Appearance Colour Dimensions Net Weight Air Filter Indoor Unit (High/Med/Low) Name of Refrigerant Larger side size Coupler style Smaller side size Coupler style Height Width Depth Height Width Depth kw kw Phase V Hz kw % A A db(a) kg m /hr W kg // R0C ø. Flare ø. Flare ø. (OD) Grey (galvanized steel & thermal insulation) Finned tube Transverse flow fan 0 x RBC-UPG(W)-E Silky white (Munsell.9Y8.9/0.8),00 0. Washable Specifications are subject to change without notice

4 Tel: Fax: SPECIFICATIONS Item Model RAV-TUH--PE RAV-TUH--PE Cooling capacity Heating capacity Power source Power consumption Power factor Running current Starting current Operating noise (SPL) Refrigerant Refrigerant control Interconnection pipe Condensate drain pipe diameter INDOOR UNIT Model Appearance colour Dimensions Net weight Heat exchanger type Indoor fan type Air volume Fan motor output OUTDOOR UNIT Model Appearance colour Dimensions Net weight Heat exchanger type Outdoor fan type Air flow volume Fan motor output Compressor Protective device Indoor Unit (High, Med, Low) Outdoor Unit Name of Refrigerant Charge Volume Add. Volume (0-0m) Larger side size Coupler style Smaller side size Coupler style Standard length Maximum actual pipe length (of one way) Maximum height difference If Indoor Unit higher If Outdoor Unit higher Height Width Depth Height Width Depth Model Output kw kw Phase V Hz kw % A A db(a) db(a) kg g/m m m m m kg m /h W kg m /h W kw COOLING HEATING // 0 R0C.0 Capillary tube & Expansion valve ø. Flare ø. Flare. 0 0 ø. (OD) RAV-TUH--PE Grey (galvanized steel & thermal insulator) Finned tube Transverse flow fan 00 x RAV-AH-PE Bronze white (Munsell Y./) Finned tube Propeller fan,00 9 PG0XF-LS COOLING HEATING // 0 R0C. Capillary tube & Expansion valve ø. Flare ø. Flare. 0 0 ø. (OD) RAV-TUH--PE Grey (galvanized steel & thermal insulator) Finned tube Transverse flow fan 0 x RAV-AH-PE Bronze white (Munsell Y./) Finned tube Propeller fan,00 9 PG0XF-LS. High pressure switch, fuse, crankcase heater, inner overload relay, bi-metal thermostat CEILING PANEL model Appearance colour Dimensions Net weight Air filter Height Width Depth kg RBC-UPG(W)-E Silky white (Munsell.9Y8.9/0.8),00 0. Washable RBC-UPG(W)-E Silky white (Munsell.9Y8.9/0.8),00 0. Washable Specifications are subject to change without notice

5 . SPECIFICATIONS Item Model RAV-TU--PE RAV-TU--PE Cooling capacity Power source Power consumption Power factor Running current Starting current Operating noise (SPL) Refrigerant Refrigerant control Interconnection pipe Condensate drain pipe diameter INDOOR UNIT Model Appearance colour Dimensions Net weight Heat exchanger type Indoor fan type Air volume Fan motor output OUTDOOR UNIT Model Appearance colour Dimensions Net weight Heat exchanger type Outdoor fan type Air flow volume Fan motor output Compressor Indoor Unit (High, Med, Low) Outdoor Unit Name of Refrigerant Charge Volume Add. Volume (0-0m) Larger side size Coupler style Smaller side size Coupler style Standard length Maximum actual pipe length (of one way) Maximum height difference If Indoor Unit higher If Outdoor Unit higher Height Width Depth Height Width Depth Model Output kw Phase V Hz kw % A A db(a) db(a) kg g/m m m m m kg m /h W kg m /h W kw COOLING // 0 R0C.0 Capillary tube ø. Flare ø. Flare. 0 0 ø. (OD) RAV-TU--PE Grey (galvanized steel & thermal insulator) Finned tube Transverse flow fan 00 x RAV-A-PE Bronze white (Munsell Y./) Finned tube Propeller fan,00 9 PG0XF-LS COOLING // 0 R0C. Capillary tube ø. Flare ø. Flare. 0 0 ø. (OD) RAV-TU--PE Grey (galvanized steel & thermal insulator) Finned tube Transverse flow fan 0 x RAV-A-PE Bronze white (Munsell Y./) Finned tube Propeller fan,00 9 PG0XF-LS. Protective device fuse, crankcase heater CEILING PANEL model Appearance colour Dimensions Net weight Air filter Height Width Depth kg RBC-UPG(W)-E Silky white (Munsell.9Y8.9/0.8),00 0. Washable RBC-UPG(W)-E Silky white (Munsell.9Y8.9/0.8),00 0. Washable Specifications are subject to change without notice Tel: Fax: 08 80

6 . CONSTRUCTION VIEWS. Indoor Unit RAV-0TUH--PE RAV-TUH--PE RAV-TUH--PE RAV-TU--PE RAV-TU--PE Hanger bolt (-M0) Drain pipe joint (outer ø.) Refrigerant piping joint (Liquid ø.) Refrigerant piping joint (Gas ø.) Wiring connection A Panel outer dimension Ceiling opening 00 Hang bolt pitch TOSHIBA View A Panel outer dimension 0 Ceiling opening 0 80 Hang bolt pitch 0 00 (Unit: ) 00 Minimum 00 Minimum 00 Minimum Space required for service and installation Tel: Fax: 08 80

7 Tel: Fax: CONSTRUCTION VIEWS. Outdoor Unit RAV-AH-PE RAV-AH-PE RAV-A-PE RAV-A-PE 0 Knock-out hole for drain (-0x0 slots) Hole for drain (xø9 hole) 0 Earth screw (M) 880 Air outlet Electric parts box 0 Terminal cover 0 Handle (Both sides) Refrigerant pipe connection (Gas ø.) Refrigerant pipe connection (Liquid ø.) 0 90 Anchor bolt hole (-x8slots) Blow out guide mounting hole (-ø embosses) Space required for service (Space for wiring and piping) Outlet (Space for wiring and piping) Outlet When installed with the inlet facing the wall When installed with the outlet facing the wall 8

8 Tel: Fax: WIRING DIAGRAMS. RAV-0TUH--PE RAV-TUH--PE RAV-TUH--PE TA TC DM GRY GRY ORG YEL BLU CN0 CN ORG BLU BLK YEL CN0 (TRANS) CN0 CN (TA) (LAN) REMOCON RY0 RY0 RY0 CN0 (TC) CN0 (FAN) H BLK M ORG L BLU UL YEL 9 9 CN RY0 (output) CN09 () (LOUVER) BLK BLK F CS Interface PCB RY0 RY0 RY0 TR TR CN0 CN0 F (L) (N) (SERIAL) (PUMP) GRY PUR GRY GRY BLK SM 0 SM 0 RC0 RC0 FM 0 YEL BLU ORG BLK Indoor unit GRN/YEL FM 0 YEL ORG BLU BLK X Y A B C X Y A B C ( Phase model) Earth Screw F L N Central Remote Controller (Optional) Remote Controller (Optional) Outdoor unit Power Supply 0/0V ~0Hz Shows terminal block and figures show terminal numbers. Broken lines show wiring at site. Do not operate the units with the magnetic contactor pushed in. Symbol Name Symbol Name FM0, 0 Fan Motor F Fuse (PCB) RC0,0 Running Capacitor F Fuse (Interface) PCB TR Transformer DM Drain Pump TA Sensor SM0, 0 Stepper Motor TC Sensor CS Float Switch RY0~RY0 Relay 9

9 Tel: Fax: WIRING DIAGRAMS. RAV-TU--PE RAV-TU--PE TA TC DM ORG YEL BLU CN0 ORG BLU BLK YEL CN REMOCON CN0 (TA) CN0 (TRANS) RY0 RY0 CN0 (TC) CN0 (FAN) H BLK M ORG L BLU YEL 9 9 RY0 (output) CN09 () (LOUVER) BLK BLK F CS Interface PCB RY0 RY RY0 RY TR TR CN0 (PUMP) F (L) (N) CN0 CN (FLOAT) 8 SM 0 SM 0 RC0 RC0 FM 0 YEL BLU ORG BLK Indoor unit GRN/YEL FM 0 YEL ORG BLU BLK A B C A B C Remote Controller (Optional) ( Phase model) Earth screw Outdoor unit F L Power supply 0/0V ~0Hz N Shows terminal block and figures show terminal numbers. Broken lines show wiring at site. Do not operate the units with the magnetic contactor pushed in. Symbol Name Symbol Name FM0, 0 Fan Motor F Fuse (PCB) RC0, 0 Running Capacitor F Fuse (Interface) PCB TR Transformer DM Drain Pump TA Sensor SM0, 0 Stepper Motor TC Sensor CS Float Switch RY0~RY Relay Relay 0

10 Tel: Fax: WIRING DIAGRAMS. RAV-AH-PE RAV-AH-PE A B C Indoor unit Earth Screw Outdoor unit TR Earth F RY0 F RY0 Wave Control Circuit TD BLK TE TL BLK BLU 9 0 B C A L H C GRY RCo FM 0 BLK 0SF 0SR HD C RCc CM 9C L Power Supply 0/0V~0Hz N CH Shows terminal block and figures show terminal numbers. Broken lines show wiring at site. Do not operate the units with the magnetic contactor pushed in. Symbol Name Symbol Name Symbol Name 0SF Solenoid coil ( way valve) CM Compressor F Fuse (TA) RY0, 0 Relay C Magnetic contactor H High pressure switch 9C Inner overload relay FMo Fan motor CH Crankcase heater 0SR Solenoid coil ( way valve) TL Sensor F Fuse (on PCB) RCc Running capacitor (compressor) TE Sensor TR Transformer RCo Running capacitor (fan motor) HD Bimetal thermostat TD Sensor (Duy)

11 Tel: Fax: WIRING DIAGRAMS. RAV-A-PE RAV-A-PE Indoor unit Outdoor unit Earth screw A C B RC c CM 9C BLK F C F F BLK ORN BLU BLK ORN BLU BLK ORN BLU FM 0 CH RC o Surge Absorber L N Power Supply 0/0V~0Hz Shows terminal block and figures show terminal numbers. Broken lines show wiring at site. Do not operate the units with the magnetic contactor pushed in. Symbol Name Symbol Name 9C Inner overload relay CM Compressor RCc Running capacitor (compressor) C Magnetic contactor RCo Running capacitor (fan motor) FMo Fan Motor F Fuse (TA) CH Crankcase heater F, Pressure Switch ( Stage)

12 Tel: Fax: SPECIFICATIONS OF ELECTRICAL PARTS. RAV-0TUH--PE No PARTS NAME TYPE SPECIFICATIONS Indoor unit fan motor (x) PAF-0-- Output (rated) W, pole, 0V, Phase, 0Hz Running capacitor for indoor fan motor (x) EVMM0UF AC 0V, 0.µF Transformer (Indoor Unit) ST-08 AC 8-V Stepper motor (x) MPEA DC V, 80mNm Drain pump PJV-0 AC 0V, 0.A Float switch FS-08-00B AC 0V, 0.A Sensor for room temperature Maximum input 8mA C kω Indoor Unit sensor for heat exchanger temperature Maximum input.ma C - 0 kω... RAV-TUH--PE No PARTS NAME TYPE SPECIFICATIONS Indoor unit fan motor (x) PAF-0-- Output (rated) W, pole, 0V, Phase, 0Hz Running capacitor for indoor fan motor (x) EEPH0HQA0 AC 00V,.0µF Transformer (Indoor Unit) ST-08 AC 8-V Stepper motor (x) MPEA DC V, 80mNm Drain pump PJV-0 AC 0V, 0.A Float switch FS-08-00B AC 0V, 0.A Sensor for room temperature Maximum input 8mA C kω Indoor Unit sensor for heat exchanger temperature Maximum input.ma C - 0 kω... RAV-TUH--PE No PARTS NAME TYPE SPECIFICATIONS Indoor unit fan motor (x) PAF-0-- Output (rated) W, pole, 0V, Phase, 0Hz Running capacitor for indoor fan motor (x) EEPH0HQA0 AC 00V,.0µF Transformer (Indoor Unit) ST-08 AC 8-V Stepper motor (x) MPEA DC V, 80mNm Drain pump PJV-0 AC 0V, 0.A Float switch FS-08-00B AC 0V, 0.A Sensor for room temperature Maximum input 8mA C kω Indoor Unit sensor for heat exchanger temperature Maximum input.ma C - 0 kω..

13 Tel: Fax: SPECIFICATIONS OF ELECTRICAL PARTS. RAV-TU--PE No PARTS NAME TYPE SPECIFICATIONS Indoor unit fan motor (x) PAF-0-- Output (rated) W, pole, 0V, Phase, 0Hz Running capacitor for indoor fan motor (x) EEPH0HQA0 AC 00V,.0µF Transformer (Indoor Unit) ST-98 AC 8-V Stepper motor (x) MPEA DC V, 80mNm Drain pump PJV-0 AC 0V, 0.A Float switch FS-08-00B AC 0V, 0.A Sensor for room temperature Maximum input 8mA C kω Indoor Unit sensor for heat exchanger temperature Maximum input.ma C - 0 kω.. 9 Relay LYF-L AC 0V, ab. RAV-TU--PE No PARTS NAME TYPE SPECIFICATIONS Indoor unit fan motor (x) PAF-0-- Output (rated) W, pole, 0V, Phase, 0Hz Running capacitor for indoor fan motor (x) EEPH0HQA0 AC 00V,.0µF Transformer (Indoor Unit) ST-98 AC 8-V Stepper motor (x) MPEA DC V, 80mNm Drain pump PJV-0 AC 0V, 0.A Float switch FS-08-00B AC 0V, 0.A Sensor for room temperature Maximum input 8mA C kω Indoor Unit sensor for heat exchanger temperature Maximum input.ma C - 0 kω.. 9 Relay LYF-L AC 0V, ab

14 Tel: Fax: SPECIFICATIONS OF ELECTRICAL PARTS. RAV-AH-PE No PARTS NAME TYPE SPECIFICATIONS Compressor PG0XF-LS Output (rated).kw, pole, 0/0V, Phase, 0Hz Outdoor unit fan motor SMF-0-9N- Output (rated) 9W, pole, 0V, Phase, 0Hz Running capacitor for outdoor fan motor EEPG0HQA AC 00V, µf Magnetic contactor FMCa-S-0 AC 0-0V, 0Hz High pressure switch ACB-TB0W Tripping pressure 0kgf/cm G Resetting pressure kgf/cm G Solenoid coil for four-way valve CHV-AC0V AC 0-0V Crankcase heater AC 0V, 8W 8 Sensor for defrosting Maximum input.ma C - 0 kω.. 9 Fuse TA 0 Sensor for cooling operation in low ambient temperature Maximum input.ma C - 0 kω.. Solenoid coil for two-way valve NEV AC 0V AC 0-0V, 0Hz Running capacitor for compressor MT-MPW AC 0V, µf Transformer (Outdoor Unit) FT- AC 8-V Bimetal thermostat CS-A Tripping temperature: 0 C Resetting temperature: 90 C

15 Tel: Fax: SPECIFICATIONS OF ELECTRICAL PARTS. RAV-AH-PE No PARTS NAME TYPE SPECIFICATIONS Compressor PG0XF-LS Output (rated).kw, pole, 0/0V, Phase, 0Hz Outdoor unit fan motor SMF-0-9N- Output (rated) 9W, pole, 0V, Phase, 0Hz Running capacitor for outdoor fan motor EEPG0HQA AC 00V, µf Magnetic contactor FMCa-S-0 AC 0-0V, 0Hz High pressure switch ACB-TB0W Tripping pressure 0kgf/cm G Resetting pressure kgf/cm G Solenoid coil for four-way valve CHV-AC0V AC 0-0V Crankcase heater AC 0V, 8W 8 Sensor for defrosting Maximum input.ma C - 0 kω.. 9 Fuse TA 0 Sensor for cooling operation in low ambient temperature Maximum input.ma C - 0 kω.. Solenoid coil for two-way valve NEV AC 0V AC 0-0V, 0Hz Running capacitor for compressor MT-MPW AC 0V, µf Transformer (Outdoor Unit) FT- AC 8-V Bimetal thermostat CS-A Tripping temperature: 0 C Resetting temperature: 90 C

16 Tel: Fax: SPECIFICATIONS OF ELECTRICAL PARTS.8 RAV-A-PE No PARTS NAME TYPE SPECIFICATIONS Compressor PG0XF-LS Output (rated).kw, pole, 0/0V, Phase, 0Hz Outdoor unit fan motor SMF-0-9N- Output (rated) 9W, pole, 0V, Phase, 0Hz Running capacitor for outdoor fan motor EEPG0HQA AC 00V, µf Magnetic contactor FMCa-S-0 AC 0-0V, 0Hz Pressure switch (-Stage) STB-X0 Tripping pressure 9kgf/cm G, kgf/cm G Resetting pressure kgf/cm G,kgf/cm G Crankcase heater AC 0V, 8W Fuse TA 8 Running capacitor for compressor MT-MPW AC 0V, µf.9 RAV-A-PE No PARTS NAME TYPE SPECIFICATIONS Compressor PG0XF-LS Output (rated).kw, pole, 0/0V, Phase, 0Hz Outdoor unit fan motor SMF-0-9N- Output (rated) 9W, pole, 0V, Phase, 0Hz Running capacitor for outdoor fan motor EEPG0HQA AC 00V, µf Magnetic contactor FMCa-S-0 AC 0-0V, 0Hz Pressure switch (-Stage) STB-X0 Tripping pressure kgf/cm G, kgf/cm G Resetting pressure kgf/cm G,kgf/cm G Crankcase heater AC 0V, 8W Fuse TA 8 Running capacitor for compressor MT-MPW AC 0V, µf

17 Tel: Fax: REFRIGERANT PIPING DIAGRAMS. Indoor Unit RAV-0TUH--PE Cooling Heating Indoor unit Heat exchanger Distributor strainer capillary tube Strainer Refrigerant pipe (Liquid) ø. (/") TC Sensor Refrigerant pipe (Gas) ø. (/") 8

18 Tel: Fax: Indoor Unit Outdoor Unit RAV-TUH--PE RAV-AH-PE. REFRIGERANT PIPING DIAGRAMS Cooling Heating Indoor unit Distributor strainer capillary tube Heat exchanger Strainer TC Sensor Refrigerant pipe (Liquid) ø. (/") Refrigerant pipe (Gas) ø. (/") Packed valve Strainer Liquid receiver Packed valve P Line pressure Cooling Heating P High pressure Low pressure P Low pressure High pressure Capillary tube ø.x00lxp Dryer Capillary tube ø.0x00lxp Expansion valve Check valve -way valve TL sensor Distributor Heat exchanger TE sensor Check joint P Strainer Capillary tube ø0.8x000lxp Four-way valve Accumulator Compressor High pressure switch Outdoor unit INDOOR UNIT Model Capillary Model OUTDOOR UNIT Main Bypass Cooling Bypass Capillary Capillary Capillary RAV-TUH--PE IDø.x00LxP RAV-AH-PE IDø.x00LxP IDø0.8x000LxP IDøx00LxP 9

19 Tel: Fax: Indoor Unit Outdoor Unit RAV-TUH--PE RAV-AH-PE. REFRIGERANT PIPING DIAGRAMS Cooling Heating Distributor strainer capillary tube Indoor unit Heat exchanger Strainer TC Sensor Refrigerant pipe (Liquid) ø. (/") Refrigerant pipe (Gas) ø. (/") Packed valve Strainer Liquid receiver Packed valve P Line pressure Cooling Heating P High pressure Low pressure P Low pressure High pressure Capillary tube ø.x00lxp Dryer Capillary tube ø.0x00lxp Expansion valve Check valve -way valve TL sensor Distributor Heat exchanger TE sensor Check joint P Strainer Capillary tube ø0.8x000lxp Four-way valve Accumulator Compressor High pressure switch Outdoor unit INDOOR UNIT Model Capillary Model OUTDOOR UNIT Main Bypass Cooling Bypass Capillary Capillary Capillary RAV-TUH--PE IDø.x00LxP RAV-AH-PE IDø.x00LxP IDø0.8x000LxP IDøx00LxP 0

20 Tel: Fax: Indoor Unit Outdoor Unit RAV-TU--PE RAV-A-PE. REFRIGERANT PIPING DIAGRAMS Indoor unit Distributor strainer & capillary tube Heat exchanger Strainer TC Sensor Refrigerant pipe (Smaller side) ø. (/") Refrigerant pipe (Larger side) ø. (/") Packed valve Packed valve Liquid tank Capillary tube Dryer Heat exchanger Distributor Strainer Compressor Pressure switch Accumulator Outdoor unit INDOOR UNIT OUTDOOR UNIT Model Capillary Model Main Capillary RAV-TU--PE IDø.x00LxP RAV-A-PE IDø.x00LxP Bypass Capillary

21 Tel: Fax: Indoor Unit Outdoor Unit RAV-TU--PE RAV-A-PE. REFRIGERANT PIPING DIAGRAMS Indoor unit Distributor strainer & capillary tube Heat exchanger Strainer TC Sensor Refrigerant pipe (Smaller side) ø. (/") Refrigerant pipe (Larger side) ø. (/") Packed valve Packed valve Liquid tank Capillary tube Dryer Heat exchanger Distributor Strainer Compressor Pressure switch Accumulator Outdoor unit INDOOR UNIT OUTDOOR UNIT Model Capillary Model Main Capillary RAV-TU--PE IDø.x00LxP RAV-A-PE IDø.x00LxP Bypass Capillary

22 Tel: Fax: PERFORMANCE CHARACTERISTICS. Cooling capacity Capacity Ratio (%) (kw) Ambient Temp. (Dry Bulb) ( C) RAV-AH-PE RAV-AH-PE Room Temp. (Wet Bulb) ( C). Heating capacity Ambient Temp. (Wet Bulb) ( C) Capacity Ratio (%) RAV-AH-PE (kw) RAV-AH-PE Room Temp. (Dry Bulb) ( C)

23 Tel: Fax: PERFORMANCE CHARACTERISTICS. Cooling capacity RAV-AH-PE RAV-AH-PE Cooling Capacity Ratio Heating Capacity Ratio Outdoor Unit Height H (m) Outdoor Unit Height H (m) H L INDOOR UNIT Piping Length L (m) Piping Length L (m). Cooling capacity RAV-A-PE RAV-A-PE Cooling Capacity Ratio Outdoor Unit Height H (m) H L INDOOR UNIT Piping Length L (m)

24 Tel: Fax: PERFORMANCE CHARACTERISTICS. Piping Length/Additional Refrigerant Volume! The amount of refrigerant put into the outdoor unit at the factory is sufficient to fill up to 0m of refrigerant pipework.!!! If the length of the refrigerant pipework is 0m or less, addition of refrigerant at the installation site is unnecessary. If the length of the pipework exceeds 0m, extra refrigerant must be added. Refer to the table below for details of the extra amounts. Overcharge or undercharge of refrigerant in the outdoor unit will cause malfunction of the compressor. The prescribed amount of the replenishment of the refrigerant is shown in the table below: Additional amount of refrigerant to add at installation site (kg)±0g Recharge amount if unit is reclaimed (kg)±0g MODEL (RAV-) Less than 0m Less than m Less than 0m Less than m Less than 0m Less than m Less than 0m Less than m Less than 0m Less than m Less than 0m Less than m Less than 0m Less than m Less than 0m AH-PE AH-PE A-PE A-PE Filled at Factory! ADD ONLY R0C REFRIGERANT TO THESE UNITS

25 Tel: Fax: EXPLODED VIEWS AND PARTS LISTS. Indoor Unit RAV-0TUH--PE RAV-TUH--PE RAV-TUH--PE RAV-TU--PE RAV-TU--PE / Ref No. Part No. Description Model A00 Blower Base Assembly All 0088 Fan-C-F All A00 Float Switch All A0008 Pump Assembly All 00 Bearing All 009 Drain Connection All A0009 Drain Hose All 8 A000 Terminal ABC XY All 9 A000 Terminal,, All 0 A9008 Interface PC Board All MF Capacitor RAV-0TUH--PE 00 MF Capacitor RAV-/TU/TUH--PE A900 PC Board (AI) RAV-0//TUH--PE A900 ASM Cont PC IN RAV-/TU--PE A800 Transformer (AI) RAV-0//TUH--PE A800 Transformer RAV-/TU--PE Ref No. Part No. Description Model Relay LYF-L RAV-/TU--PE A0 Fan Motor (PAF-0--) All A000 Sensor Holder All A008 Motor Band L All 8 A009 Motor Band R All 9 A00 Refrigeration Assembly RAV-0TUH--PE 9 A0 RefrigerationAssembly RAV-TU/TUH--PE 9 A0 Refrigeration Assembly RAV-TU/TUH--PE 0 A00 Drain Pan All A800 Drain Guide Assembly All A880 Owner Manual All 08 Sensor Room Temperature RAV-/TU--PE A0008 Sensor Room Temperature RAV-0//TUH--PE A000 Sensor Heat Exchanger All A00 TC Adapter RAV-0//TUH--PE

26 Tel: Fax: EXPLODED VIEWS AND PARTS LISTS. Outdoor Unit RAV-AH-PE RAV-AH-PE Ref No. Part No. Description Model 0 Propeller Fan All A00 Fan Motor All A0 Condensor All 09 Base Spring, B All 9 Base Spring, A All 998 Spring Buffer All A90 PC Board All 8 A900 High Pressure Switch All Terminal Block, P All 0 A000 Terminal Block, P All A000 Terminal Block, P All Magnetic Contactor All A900 Fan Guard All 98 Hanger All A00 Solenoid Coil All 0 Cover, Electrical Parts All 0 Sensor Holder All 8 A00 Cord Clamp All 9 80 Accumulator All 0 A00 Dryer All MF Capacitor Compressor All 080 MF Capacitor Fan All Ref No. Part No. Description Model A0 Comp PG0XF-LS RAV-AH-PE A0 Comp PG0XF-LS RAV-AH-PE 0 Packed Valve (.) All A0 Packed Valve (.) All A0 Check Joint All A0 Expansion Valve All 8 A0 Coil, -Way Valve All 9 8 Check Valve All 0 A800 Transformer Power All 0 -Way Valve All A000 Sensor Heat Exchanger (TL) All A900 Sensor Heat Exchanger (TC) All 90 Spring All Heater, Crankcase All 0 Thermostat, Bi-metal All 8 A000 Fuse TA All 9 8 -Way Valve All 0 A0 Capi Form All A90 ASM Roof Plate All A909 ASM Side Cabinet All A90 ASM Air-Out Cabinet All A90 Fin-Guard (back) All

27 Tel: Fax: EXPLODED VIEWS AND PARTS LISTS. Outdoor Unit RAV-A-PE RAV-A-PE Ref No. Part No. Description Model 0 Propellor Fan All A0 Fan Motor All A0 Condensor All 09 Base Spring, B All 9 Base Spring, A All 998 Spring Buffer All 98 Surge Absorber All 8 A900 Pressure Switch ( stage) All 9 A000 Terminal Block, P All 0 A000 Terminal Block, P All Magnetic Contactor All A900 Fan Guard All 98 Hanger All 0 Cover, Electrical Parts All A00 Cord Clamp All 80 Accumulator All Ref No. Part No. Description Model A00 Dryer All 8 MF Capacitor Compressor All MF Capacitor Fan All 0 A0 Comp PG0XF-LS RAV-A-PE 0 A0 Comp PG0XF-LS RAV-A-PE 0 Packed Valve (.) All A0 Packed Valve (.) All 90 Spring All Heater, Crankcase All A000 Fuse TA All A0 Capi Form All 8 A90 ASM Roof Plate All 9 A909 ASM Side Cabinet All 0 A90 ASM Air-Out Cabinet All A90 Fin-Guard (back) All 8

28 Tel: Fax: EXPLODED VIEWS AND PARTS LISTS. Ceiling Panel RBC-UPG(W)-E Ref No Part No. Description 0809 Filter 0008 Plate Connect (Long) 0090 ASM-Grille-Out 000 Bushing 0009 Plate Connect (Short) Ref No Part No. Description 0090 Grille-L-R 00 Support Plate ASM-Grille-Out 9 ASM-Motor 0 00 Support Plate 9

29 Tel: Fax: NOTES 0

30 Tel: Fax: TOSHIBA AIR CONDITIONING MADE IN UK A90-00

SERVICE MANUAL AIR CONDITIONER SPLIT TYPE

SERVICE MANUAL AIR CONDITIONER SPLIT TYPE FILE No. A90-961 SERVICE MANUAL AIR CONDITIONER SPLIT TYPE WAY CASSETTE TYPE RAV-133TU-PE/RAV-13A-PE RAV-163TU-PE/RAV-18A-PE Printed in UK Dec 1996 s CONTENTS 1. SPECIFICATION...3. CONSTRUCTION VIEWS...5

More information

AIR-CONDITIONER SERVICE MANUAL

AIR-CONDITIONER SERVICE MANUAL FILE NO. A90-9608 SERVICE MANUAL AIR-CONDITIONER S SPLIT BUILT-IN DUCT TYPE RAV-362B-PE/ RAV-462B-PE/ SPLIT CEILING TYPE RAV-362C-PE/ RAV-462C-PE/ SPLIT CASSETTE TYPE RAV-362U-PE/ RAV-462U-PE/ PRINTED

More information

Digital Inverter 4 series 8 & 10HP

Digital Inverter 4 series 8 & 10HP E6-H Digital Inverter 4 series 8 & 0HP High static duct type Indoor unit RAV-SM2244DTP-E RAV-SM2804DTP-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents. Line up... 2. Indoor unit (High static duct

More information

Compact 4-way Cassette ( ) Type

Compact 4-way Cassette ( ) Type E08-0 Engineering Data Compact 4-way Cassette (600 600) Type Indoor Unit RAV-SM40MUT-E RAV-SM4MUT-E Outdoor Unit RAV-SP404AT-E RAV-SP44AT-E Contents. Specifications. Connecting pipe length and lift difference

More information

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE -(1) SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-24UKHP-E3 / RAS-24UAH-E3 RAS-18UKHP-E3 / RAS-18UAH-E3 RAS-24UKP-E3 / RAS-24UA-E3 RAS-18UKP-E3 / RAS-18UA-E3 RAS-24UKP-AR3 / RAS-24UA-AR3 RAS-18UKP-AR3

More information

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA ARGO 245C / 3SC Cooling only model ARGO 235H / 3HP Heat pump model 0.8180.405.2 09/2006 Table of contents Page A SPECIFICATIONS 1) Unit specifications 3

More information

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE FILE. SVM-04004-3 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-13UKHP-E3 / RAS-13UAH-E3 RAS-10UKHP-E3 / RAS-10UAH-E3 RAS-07UKHP-E3 / RAS-07UAH-E3 RAS-13UKP-E3 / RAS-13UA-E3 RAS-10UKP-E3 / RAS-10UA-E3

More information

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE FILE. SVM-05009-2 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-24UKHP-E4 / RAS-24UAH-E4 RAS-18UKHP-E4 / RAS-18UAH-E4 RAS-24UKP-E4 / RAS-24UA-E4 RAS-18UKP-E4 / RAS-18UA-E4 RAS-24UKP-AR4 / RAS-24UA-AR4

More information

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit RCW-54CB RO-50CA RC-54CA RO-50CA RC-54HA RO-50HA CONTENTS SPECIFICATIONS OUTLINE AND DIMENTIONS CIRCUIT DIAGRAM REFRIGERANT SYSTEM

More information

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA 0.8180.472.0 07/2005 Page 1. SPECIFICATIONS 3 1-1 Unit Specifications 3 1-2 Major Component Specifications 4 2. DIMENSIONAL DATA 6 2-1 Unit Dimensions 6 3. ELECTRICAL

More information

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE Indoor unit ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LBT ABYF8LBT ABYFLAT ABYFLAT ABYFLAT ABYFLAT ABYFLBT ABYFLBT Outdoor unit AOYA8LACL

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: CAF97R5IAA CAF98MR5IAA CAF127R5IAA CAF128MR5IAA CAF187R5IAA SPLIT SYSTEM AIR CONDITIONER Model No. CAF97R5IAA CAF127R5IAA CAF187R5IAA CAF98MR5IAA CAF128MR5IAA

More information

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE FILE. SVM-05010-2 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE 42CJR024-723 / 38CJR024-723 42CJR018-723 / 38CJR018-723 42TAR024X-723 / 38TAR024X-723 42TAR018-723 / 38TAR018-723 42HNR024-713 / 38HNR024-713

More information

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2 INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS................................... 1

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338 TECHNICAL & SERVICE MANUAL SA 128S5 FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-128S5-A 1 851 004 09 General (50Hz) & Europe SA 128S5 REFERENCE NO. SM700338 IMPORTANT!

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL XHS1271 & PNR-XS1872 + CH1271 XHS1872 & PNR-XS1872 + CH1872 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel) XHS1271

More information

SERVICE MANUAL SPLIT TYPE

SERVICE MANUAL SPLIT TYPE FILE. A0-04 SERVICE MANUAL SPLIT TYPE RAV-SM560AT-E/RAV-SM800AT-E RAV-SM560UT-E/RAV-SM800UT-E RAV-SM560BT-E/RAV-SM800BT-E RAV-SM560KRT-E/RAV-SM800KRT-E RAV-SM560XT-E/RAV-SM800XT-E R40A PRINTED IN JAPAN,

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2017-4-25 New CMV System - Floor ceiling Indoor Unit 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram

More information

CASSETTE type INVERTER MULTI AIR CONDITIONER

CASSETTE type INVERTER MULTI AIR CONDITIONER INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT

More information

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV Amendment Sheet Code : M5ACV-2005-0002 Date : 08-05-2006 Superceded : M5ACV-2005-0001 Nomenclature Production spec variation Type of ref. connection X : Not applicable Electrical A : 220-240V/1Ph/50Hz

More information

11. WALL MOUNTED TYPE PACKAGED AIR CONDITIONER Split system, Air cooled cooling only type

11. WALL MOUNTED TYPE PACKAGED AIR CONDITIONER Split system, Air cooled cooling only type 11. WALL MOUNTED TYPE PACKAGED AIR CONDITIONER ( Split system, Air cooled ) cooling only type FDKN8CEN-S, FDKN8CEP-S, FDKN8CEN FDKN8CEP, FDKN258CEN-S, FDKN258CEP-S FDKN258CEN, FDKN258CEP, FDKN8CEN FDKN8CEP,

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-A Models MUZ-SF25VE - E1 MUZ-SF42VE

More information

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit SPLIT TYPE AIR CONDITIONER CASSETTE type (50Hz) Models Indoor unit Outdoor unit RCW-12HA RO-12HB C O N T E N T S SPECIFICATIONS........................................ 1 OUTLINE AND DIMENSIONS..............................

More information

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER CEILING type (60Hz) Models Indoor unit ABU6RSLX Outdoor unit AOU6RLX CONTENTS SPECIFICATIONS....................... OUTLINE AND DIMENSIONS............. REFRIGERANT SYSTEM

More information

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E Revision E: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH629 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-E Models

More information

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz) Indoor unit MS6YF Outdoor unit MR6YF CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM.... CIRCUIT DIAGRAM... INDOOR PCB

More information

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE FILE. SVM-06005 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-18NKHD-E5 / RAS-18NAH-E RAS-18NKD-E5 / RAS-18NA-E RAS-24NKD-E5 / RAS-24NA-E RAS-18NKDX5 / RAS-18N2AX RAS-24NKDX5 / RAS-24N2AX 18 Class

More information

Кондиционеры Mitsubishi Heavy

Кондиционеры Mitsubishi Heavy Кондиционеры Mitsubishi Heavy Техническое руководство Кондиционеры настенного типа SRK28HD, SRK40HD INDOOR UNIT Models SRK28HD, SRK40HD OUTDOOR UNIT Model SRC28HD REMOTE CONTROLLER Model SRC40HD GENERAL

More information

FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz)

FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz) Models Indoor unit MSYF Outdoor unit MRUYF CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM...

More information

Air to Water Heat Pump

Air to Water Heat Pump E15-381 Engineering Data Book Air to Water Heat Pump Hydro Unit HWS-804XWHM3-E1 HWS-804XWHT6-E1 HWS-804XWHT9-E1 HWS-1404XWHM3-E1 HWS-1404XWHT6-E1 HWS-1404XWHT9-E1 Outdoor Unit 8 kw 11/14/16 kw HWS-804H-E1

More information

FLOOR CONSOLE / UNDER CEILING DUAL type

FLOOR CONSOLE / UNDER CEILING DUAL type SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL type Models Indoor unit ABU8RULX ABURULX Outdoor unit AOU8RLX AOURLX CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT

More information

RAS-10JKVP-E RAS-10JAVP-E RAS-13JKVP-E RAS-13JAVP-E

RAS-10JKVP-E RAS-10JAVP-E RAS-13JKVP-E RAS-13JAVP-E FILE NO. A0-05 SPLIT TYPE RAS-0JKVP-E RAS-0JAVP-E RAS-3JKVP-E RAS-3JAVP-E PRINTED IN JAPAN, Jun.,003 ToMo . EXPLODED VIEWS AND PARTS LIST -. Indoor Unit () 0 0 6 35 5 4 0 5 33 7 08 6 07 9 3 0 3 8 30 39

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models CONTENTS

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models CONTENTS SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS.................. 1 OUTLINE AND DIMENSIONS.........

More information

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax: TECHNICAL MANUAL CX(E) SPLIT SYSTEMS CONTENTS INDEX PART NUMBERS, OPTIONS, UNIT COMBINATIONS, DIMENSIONS & WEIGHTS 3 PERFORMANCE DATA & AIR FLOW 4 SOUND POWER AND SOUND PRESSURE LEVELS 5 ELECTRICAL DATA

More information

TOSHIBA AIR CONDITIONING

TOSHIBA AIR CONDITIONING Digital Inverter Standard Specification R32 Introduction The following specification describes the Toshiba Digital Inverter Heat Pump air conditioning system(s) to be installed at the below site: (ADD

More information

MUH-24RV - MSH-30RV -

MUH-24RV - MSH-30RV - SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SERVICE MANUAL Wireless type Models Refer to the Service Manual OB85 REVISED EDITION C when MSH-8RV- E is connected with MXZ-NV- E or MXZ-NV- E as multi system units.

More information

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL SAP K161GJA SAP K181GJA SAP K181MBA SAP K241GJA SAP K241MBA + SAP C161GA + SAP C161JA + SAP C181GA + SAP C181JA + SAP C181MA + SAP C181BA + SAP C241GA + SAP C241JA + SAP C241MA

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH530 Models MU-GE50VB- E1 - E1 Indoor unit service manual MS/MSH-GE VB Series (OBH529) CONTENTS 1. TECHNICAL CHANGES 2 2. PART

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: ASR609CL ASR612CL ASR609CL ASR612CL

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: ASR609CL ASR612CL ASR609CL ASR612CL TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: ASR609CL ASR612CL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. ASR609CL 387006970 ASR612CL 387006971 0.8180.250.0 05/2002 IMPORTANT! Please read

More information

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC Revision F: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH590 REVISED EDITION-E. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED EDITION-F

More information

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit SPLIT TYPE AIR CONDITIONER CASSETTE type (50Hz) Models Indoor unit Outdoor unit RCW-8CA RCW-8HA RO-8CB RO-8HB C O N T E N T S SPECIFICATIONS........................................ OUTLINE AND DIMENSIONS..............................

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS.................. 1 OUTLINE AND DIMENSIONS.........

More information

CASSETTE type SPLIT TYPE AIR CONDITIONER. (60Hz) AUU18RCLX AUU24RCLX AUU36RCLX AUU42RCLX AOU18RLX AOU24RLX AOU36RLX AOU42RLX CONTENTS.

CASSETTE type SPLIT TYPE AIR CONDITIONER. (60Hz) AUU18RCLX AUU24RCLX AUU36RCLX AUU42RCLX AOU18RLX AOU24RLX AOU36RLX AOU42RLX CONTENTS. SPLIT TYPE AIR CONDITIONER CASSETTE type (60Hz) Models Indoor unit AUU8RCLX AUURCLX AUU6RCLX AUURCLX Outdoor unit AOU8RLX AOURLX AOU6RLX AOURLX CONTENTS SPECIFICATIONS... DIMENSIONS... REFRIGERANT SYSTEM

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: CAF94R5 CAF124R5 CAF94R

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: CAF94R5 CAF124R5 CAF94R TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: CAF94R5 CAF124R5 SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. CAF94R5 387106979 CAF124R5 387106980 0.8180.361.0 07/2005 IMPORTANT! Please read before

More information

DUCT type. Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

DUCT type. Большая библиотека технической документации   каталоги, инструкции, сервисные мануалы, схемы. SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit RD-25CA RD-25HA RD-30CA RD-30HA RO-25CA RO-25HA RO-30CA RO-30HA C O N T E N T S SPECIFICATIONS.............................................

More information

SERVICE Manual SYSTEM AIR CONDITIONER INDOOR UNIT GH052EAM GH070EAM OUTDOOR UNIT UH052EAMT UH070EAMT. 1. Product Specifications

SERVICE Manual SYSTEM AIR CONDITIONER INDOOR UNIT GH052EAM GH070EAM OUTDOOR UNIT UH052EAMT UH070EAMT. 1. Product Specifications SYSTEM AIR CONDITIONER INDOOR UNIT GH052EAM GH070EAM OUTDOOR UNIT UH052EAMT UH070EAMT SERVICE Manual SYSTEM AIR CONDITIONER CONTENTS 1. Product Specifications 2. Disassembly and Reassembly 3. Set Up the

More information

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE FILE. SVM-06004 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-18NKHP-E / RAS-18NAH-E RAS-18NKP-E / RAS-18NA-E RAS-24NKP-E / RAS-24NA-E RAS-B18NKPX / RAS-18N2AX RAS-24NKPX / RAS-24N2AX 18 Class 24

More information

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2 Revision F: "How to check miswiring and serial signal error" has been corrected (11-5. M ). OBH648 REVISED EDITION-E is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH648 REVISED EDITION-F Models

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC Revision E: MUZ-FH25VE- E4, ER4, ET3, MUZ- FH35VE- E3, ER3, ET3 and MUZ- FH50VE- E2, ER2, ET2 have been added. Please void OBH624 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL XS171 & PNRXS187 + C171 XS171 & PNRXS187 + CL171 XS187 & PNRXS187 + CH187 XS187 & PNRXS187 + CL187 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL KS1872 + C1872 + CL1872 KS2472 + C2472 + CL2472 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KS1872 KS2472 Product

More information

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589)

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589) SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 Models MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL XHS7 & PNRXS87 + CH7 XHS87 & PNRXS87 + CH87 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel) XHS7 (PNRXS87) XHS87 (PNRXS87)

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: GRF188R5TAA GRF228R5TAA GRF228R7TAA SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. GRF188R5TAA 38.7107.083 GRF228R5TAA 38.7107.084 GRF228R7TAA 38.7107.085

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL INDOOR UNIT : CS-MKE9NB4U & CZ-18BT1U CS-MKE12NB4U & CZ-18BT1U CS-KE18NB4UW & CZ-18BT1U DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 9,000BTU / h 11,900BTU / h 17,500BTU

More information

FILE NO. SVM SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-24NKHP-E / RAS-24NAH-E RAS-18NKPX-T / RAS-18N2AX-T RAS-24NKPX-T / RAS-24N2AX-T

FILE NO. SVM SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-24NKHP-E / RAS-24NAH-E RAS-18NKPX-T / RAS-18N2AX-T RAS-24NKPX-T / RAS-24N2AX-T FILE. SVM-06009 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-24NKHP-E / RAS-24NAH-E RAS-18NKPX-T / RAS-18N2AX-T RAS-24NKPX-T / RAS-24N2AX-T June, 2006 CONTENTS FILE. SVM-06009 1. SPECIFICATIONS 2.

More information

Air to Water Heat Pump

Air to Water Heat Pump E7- Air to Water Heat Pump Hydro Unit HWS-55XWHM-E HWS-805XWHM-E HWS-805XWHT6-E HWS-805XWHT9-E HWS-05XWHM-E HWS-05XWHT6-E HWS-05XWHT9-E HWS-P805XWHM-E HWS-P805XWHT6-E HWS-P805XWHT9-E HWS-P05XWHM-E HWS-P05XWHT6-E

More information

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1 SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH

More information

TABLE OF CONTENTS ERSQ-AAY1

TABLE OF CONTENTS ERSQ-AAY1 Daikin Altherma High Temperature Outdoor units ERSQ-AAY1 TABLE OF CONTENTS ERSQ-AAY1 1 Features............................................................ 6 2 Specifications......................................................

More information

AIR-CONDITIONER SERVICE MANUAL UNDER CEILING / CONSOLE TYPE

AIR-CONDITIONER SERVICE MANUAL UNDER CEILING / CONSOLE TYPE FILE. SVM-02009 SERVICE MANUAL AIR-CONDITIONER UNDER CEILING / CONSOLE TYPE RAS-18UFHP-ES / RAS-18UAH-ES RAS-18UFP-ES / RAS-18UA-ES RAS-24UFHP-ES / RAS-24UAH-ES RAS-24UFP-ES / RAS-24UA-ES 18 Class 24 Class

More information

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER Manual No. '06 PAC, KX-T-110 TECHNICAL MANUAL Collection data PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) FDUMVA201HEN2R 251HEN2R 302HEN2R 402HEN2R 502HEN2R 602HEN2R MULTI-TYPE (V-MULTI)

More information

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100 Ceiling cassette (-way flow type) RA Data G8 -P-VBM-E. SPECIFICATIONS - 98. EXTERNAL DIMENSIONS - 99 3. CENTER OF GRAVITY -. ELECTRICAL WIRING DIAGRAMS -. SOUND LEVELS -. Sound levels -. NC curve 6. TEMPERATURE/AIRFLOW

More information

SERVICE MANUAL MUZ-GE50VA - E1 MUZ-GE50VAH - E1 MUZ-GE60VA - E1 MUZ-GE71VA - E1

SERVICE MANUAL MUZ-GE50VA - E1 MUZ-GE50VAH - E1 MUZ-GE60VA - E1 MUZ-GE71VA - E1 SPLIT-TYPE AIR CONDITIONERS Revision D: Changing defrost finish temperature has been corrected (10-1.). Please void OBH516 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED

More information

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling TECHNICAL INSTRUCTIONS CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT Cooling Heating CWX 3 pipes.60 3.9 pipes + electric heating.08.96 +.5 pipes.08.5 CWX 5 pipes.70 5.70 pipes + electric heating.3 5.3 +.50

More information

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624 REVISED EDITION-A Models MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE

More information

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467. SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-HC35VA- E2 and MUZ-HC35VAB- E2 have been added. Please void OBH467 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH467 REVISED EDITION-B

More information

WALL MOUNTED TYPE ROOM AIR-CONDITIONER

WALL MOUNTED TYPE ROOM AIR-CONDITIONER TECHNICAL MANUAL & PARTS LIST DRAFT WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type) SRK50HE-S, SRK56HE-S (Split system, air cooled cooling only type) SRK50CE-S, SRK56CE-S

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 93AH FILE NO. SA 93AH REFERENCE NO. SM700510

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 93AH FILE NO. SA 93AH REFERENCE NO. SM700510 TECHNICAL & SERVICE MANUAL SA 93AH FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-93AH 1 851 006 97 Australia SA 93AH REFERENCE NO. SM700510 IMPORTANT! Please Read Before

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513 TECHNICAL & SERVICE MANUAL SA 123A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-123A 1 851 006 95 Australia SA 123A REFERENCE NO. SM700513 IMPORTANT! Please Read Before

More information

RAS-24UKHP-ES-1 / RAS-24UAH-ES-1 RAS-18UKHP-ES2 / RAS-18UAH-ES2 RAS-24UKP-ES-1 / RAS-24UA-ES-1 RAS-18UKP-ES2 / RAS-18UA-ES2

RAS-24UKHP-ES-1 / RAS-24UAH-ES-1 RAS-18UKHP-ES2 / RAS-18UAH-ES2 RAS-24UKP-ES-1 / RAS-24UA-ES-1 RAS-18UKP-ES2 / RAS-18UA-ES2 FILE. SVM-03009 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-24UKHP-ES-1 / RAS-24UAH-ES-1 RAS-18UKHP-ES2 / RAS-18UAH-ES2 RAS-24UKP-ES-1 / RAS-24UA-ES-1 RAS-18UKP-ES2 / RAS-18UA-ES2 18 Class (Heat

More information

Concealed Ducted Split Series R-407C MBH

Concealed Ducted Split Series R-407C MBH Concealed Ducted Split Series R-407C 4-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION NOMENCLATURE UNIT RATING SUMMARY

More information

WALL MOUNTE SPLIT T YPE ROOM AIR CONDITIONER. type. Models. Models. Outdoor Unit Serial No. Starting with T ( Compressor Recipro type )

WALL MOUNTE SPLIT T YPE ROOM AIR CONDITIONER. type. Models. Models. Outdoor Unit Serial No. Starting with T ( Compressor Recipro type ) SPLIT T YPE ROOM AIR CONDITIONER WALL MOUNTE type Models Outdoor Unit Serial No. Starting with T000001 ( Compressor Recipro type ) Indoor unit ASU18C1 ASU18R1 ASU24C1 ASU24R1 ASU30C1 Outdoor unit AOU18C1

More information

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type) TECHNICAL MANUAL & PARTS LIST DRAFT INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type) SRK20ZD-S - 1 - INDOOR UNIT Model SRK20ZD-S OUTDOOR UNIT Model SRC20ZD-S REMOTE

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A TECHNICAL & SERVICE MANUAL SA 183A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. SA-183A 1 851 006 96 Destination Australia SA 183A REFERENCE NO. SM700514 IMPORTANT! Please Read Before

More information

6. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air cooled cooling only type)

6. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air cooled cooling only type) 6. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air cooled cooling only type) (OUTDOOR UNIT) (INDOOR UNIT) SKM222CENG-L SKM252CENG-L SKM402CENG-L 221 CONTENTS 6.1 GENERAL INFORMATION... 223 6.1.1

More information

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT TECHNICAL INSTRUCTIONS CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT Cooling Heating CWX 6 2 pipes 6.00 kw 7.70 kw CWX 8 2 pipes 8.00 kw 10.50 kw CWX 10 2 pipes 9.92 kw 13.00 kw November 2008 10 12

More information

RAS-24SKP-ES2 / RAS-24SA-ES2 RAS-24SKHP-ES2 / RAS-24S2AH-ES2

RAS-24SKP-ES2 / RAS-24SA-ES2 RAS-24SKHP-ES2 / RAS-24S2AH-ES2 FILE. SVM-10049 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-24SKP-ES2 / RAS-24SA-ES2 RAS-24SKHP-ES2 / RAS-24S2AH-ES2 April, 2010 CONTENTS FILE. SVM-10049 1. SPECIFICATIONS 2. CONSTRUCTION VIEWS

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL KHS308 + CH308 KHS368 + CH368 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. KHS308 KHS368 Product Code No. 85 354 8 85 354 9 Outdoor

More information

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons Product Data 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes 2to4NominalTons The 40QK Energy-Efficient In Ceiling Cassette fan coil incorporates innovative technology to provide

More information

CONTENTS 1. SPECIFICATIONS CONSTRUCTION VIEWS Indoor Unit Outdoor Unit... 7

CONTENTS 1. SPECIFICATIONS CONSTRUCTION VIEWS Indoor Unit Outdoor Unit... 7 6 5 0 1 * ).1 - ) '$' 5-4 8 1 + - ) 7 ) ) 1 4 +, 1 6 1 5 2 1 6 9 ) 6 4 ) 5 5 04 ) - 5 5 ) 0 4 ) 5 5 40 ): 5 5 ) 0 2 4 1 6 -, 1 ) 2 ) L ' ' $ CONTENTS 1. SPECIFICATIONS... 4 2. CONSTRUCTION VIEWS... 6 2-1.

More information

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC Revision D: MUFZ-KJ25VE - E2, ER2, ET2, MUFZ- KJ35VE - E2, ER2, ET2 and MUFZ- KJ50VE - E2, ER2, ET2 have been added. Please void OBH667 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A.

More information

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED

More information

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA ARGO 245SCH2O( I ) Cooling only model ARGO 235HPH2O( I ) Heat pump model 0.8180.519.1 11 / 2007 Table of contents Page A SPECIFICATIONS 1) Unit specifications

More information

KPSW CONSOLE TERMINAL UNIT

KPSW CONSOLE TERMINAL UNIT TECHNICAL INSTRUCTIONS KPSW CONSOLE TERMINAL UNIT Cooling Heating KPSW.40 kw.75 kw KPSW.9 kw 4.07 kw KPSW 4.60 kw 5.0 kw November 008 0 7 - GB - 0 MARKING This product marked conforms to the essential

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL TECHNICAL & SERVICE MANUAL INDOOR UNIT: MCAF94MR5IAA MCAF124MR5IAA MCAF184MR5IAA MCAF244MR5IAA NOV.2003 Destination: General area (50Hz) Europe (50Hz) Australia (50Hz) General area (60Hz) DC INVERTER MULTI-SYSTEM

More information

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6 DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6 1.1. REFERENCE STANDARDS 1.2. GENERAL 1.1.1. The units shall be listed by Electrical Testing Laboratories (ETL) and bear the ETL label. 1.1.2.

More information

Air Conditioner SVC MANUAL(Exploded View)

Air Conditioner SVC MANUAL(Exploded View) Internal Use Only http://biz.lgservice.com Air Conditioner SVC MANUAL(Exploded View) Type : Ceiling Concealed Duct MODEL : AMNW24GBGA0 [LMHN240HV] AMNW36GBGA0 [LMHN360HV] CAUTION Before Servicing the unit,

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL CS-KE30NKU + CU-KE30NKU CS-KE36NKU + CU-KE36NKU DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. CS-KE30NKU CS-KE36NKU Product Code No. 1 852 360 88

More information

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: AE726SCL AE752SCL AE71SCL3 AE735SCL AE752SCL3 AE100SCL3 AE764SCL3 AE125SCL3 SPLIT SYSTEM AIR CONDITIONER Model No. AE726SCL AE735SCL AE752SCL AE752SCL3 AE764SCL3

More information

SMi System. Applications Manual SMI-01AE-06-03

SMi System. Applications Manual SMI-01AE-06-03 SMi System Applications Manual SMI-01AE-06-03 Contents Page Chapter General Information 4 1 Indoor Units General 9 2 4-Way Cassette 12 3 2-Way Cassette 21 4 Duct 25 5 Slim Duct 31 6 Ceiling 35 7 High

More information

SERVICE MANUAL AIR-CONDITIONER (SPLIT TYPE)

SERVICE MANUAL AIR-CONDITIONER (SPLIT TYPE) -1 SERVICE MANUAL AIR-CONDITIONER (SPLIT TYPE) OUTDOOR UNIT RAV-SM564ATP-E (TR) RAV-SM804ATP-E (TR) RAV-SM1104ATP-E (TR) RAV-SM1404ATP-E (TR) RAV-SM564ATJP-E RAV-SM804ATJP-E RAV-SM1104ATJP-E

More information

AIR-CONDITIONER SERVICE MANUAL SPLIT WALL TYPE RAS-24UKX / RAS-24UAX RAS-24UK-AR / RAS-24UA-AR RAS-18UKX / RAS-18UAX RAS-18UK-AR / RAS-18UA-AR

AIR-CONDITIONER SERVICE MANUAL SPLIT WALL TYPE RAS-24UKX / RAS-24UAX RAS-24UK-AR / RAS-24UA-AR RAS-18UKX / RAS-18UAX RAS-18UK-AR / RAS-18UA-AR FILE. SVM-01010 SERVICE MANUAL AIR-CONDITIONER SPLIT WALL TYPE RAS-24UKX / RAS-24UAX RAS-24UK-AR / RAS-24UA-AR RAS-18UKX / RAS-18UAX RAS-18UK-AR / RAS-18UA-AR 18 Class 24 Class Dec., 2001 CONTENT FILE.

More information

TOSHIBA Carrier (UK) Ltd. LC DX Interface Installation manual ENGLISH. For commercial use. Model name:

TOSHIBA Carrier (UK) Ltd. LC DX Interface Installation manual ENGLISH. For commercial use. Model name: TOSHIBA Carrier (UK) Ltd. LC DX Interface Installation manual Model name: For commercial use RAV-DXC010 LC DX Interface ENGLISH Please read this carefully before installing the LC DX interface. This Manual

More information

Product Data FEATURES AND BENEFITS. QHF 50Hz Heat Pump Inverter Single Phase 2.5kW to 8.0kW

Product Data FEATURES AND BENEFITS. QHF 50Hz Heat Pump Inverter Single Phase 2.5kW to 8.0kW 0Hz Heat Pump Inverter Single Phase.kW to 8.0kW turn to the experts Product Data FEATURES AND BENEFITS AVAILABLE SIZES: Nominal capacity are available from.kw through 8.0kW to meet the needs of residential

More information

RAV-SP180AT2-UL (2 HP) RAV-SP240AT2-UL (3 HP) RAV-SP300AT2-UL (4 HP) RAV-SP360AT2-UL (4, 5 HP) RAV-SP420AT2-UL (5 HP)

RAV-SP180AT2-UL (2 HP) RAV-SP240AT2-UL (3 HP) RAV-SP300AT2-UL (4 HP) RAV-SP360AT2-UL (4, 5 HP) RAV-SP420AT2-UL (5 HP) SERVICE MANUAL FILE. A09-00-2 Revised : Feb. 200 REVISI 2 : Jan.202 Re-edit version.( file volume down) Contents have T been changed. OUTDOOR UNIT SPLIT TYPE RAV-SP80AT2-UL (2

More information

TECHNICAL & SERVICE MANUAL. Ceiling Concealed

TECHNICAL & SERVICE MANUAL. Ceiling Concealed STAND BY DEFROST CHECK CLOCK ON OFF NOT AVAILABLE FILTER CHECK MODE TEST RUN FUNCTION SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL Series SEZ Ceiling Concealed R40A.OC0 REVISED EDITION-A

More information

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz ENVIRONMENTALLY SOUND REFRIGERANT N4H4 Performance Series Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Service Manual AIR TO WATER HEAT PUMP. Outdoor unit. Hydro unit HWS-P805XWHM3-E(TR) HWS-P805HR-E(TR) HWS-P805XWHT6-E(TR) HWS-P1105HR-E(TR)

Service Manual AIR TO WATER HEAT PUMP. Outdoor unit. Hydro unit HWS-P805XWHM3-E(TR) HWS-P805HR-E(TR) HWS-P805XWHT6-E(TR) HWS-P1105HR-E(TR) FILE. A10-1705 AIR TO WATER HEAT PUMP Service Manual Model name: Hydro unit Outdoor unit HWS-P805XWHM3-E(TR) HWS-P805HR-E(TR) HWS-P805XWHT6-E(TR) HWS-P1105HR-E(TR) HWS-P805XWHT9-E HWS-P1105XWHM3-E(TR)

More information