Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries

Size: px
Start display at page:

Download "Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries"

Transcription

1 Bulletin 290-B Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries Packaged Piping Solutions - Steam Distribution Manifolds - Condensate Collection Assemblies - Trap Valve Stations - ASME Pump Trap Assemblies Condensate Improvement Services - Condensate removal for improved heat transfer - Condensate retrieval for fuel, water and chemical savings - Sense, locate and detect condensate contaminants to save energy and to protect boilers Trap Management Services - Steam Trap Surveys - Steam Trap Monitoring/Reporting - Steam Trap Turnkey Installations

2 Armstrong Packaged Piping Solutions Steam Distribution Manifold Condensate Collection Assembly TVS 4000 Trap Valve Station ASME Pump Trap Assembly 2

3 Armstrong Packaged Piping Solutions Simplify Your Steam Tracing Line Systems Designed to simplify and supply all the components (steam traps, manifolds, valves, etc.) necessary for your drip and tracer line applications, Armstrong s Steam Distribution, Condensate Collection Manifolds, and Trap Valve Stations bring all components together to reduce installation costs and provide a compact, easily accessible, centrally located assembly. Steam Distribution Manifolds As a Steam Distribution Assembly (MSD/SMSD), the manifold places all steam supply valves in one location. Standardizing components and centralizing their location simplifies installation, cutting costs from the beginning and increasing safety. You also save because routine maintenance is faster. Condensate Collection Manifolds To make industry s trapping and valving more efficient, Armstrong combines its TVS 4000 stainless steel trap valve stations with manifolds into a package called the Condensate Collection Assembly (CCA). This prepackaged assembly offers many great benefits cost savings in installation, design flexibility, reduced purchasing time, and provides personnel safety. The model CCAF also includes syphon tube freeze protection. TVS 4000 Trap Valve Station With Integrated Valves Reduces Piping Costs and Saves Space The TVS 4000 is a connector that packages two piston-style isolation valves, test valve and stainless steel strainer with blowdown valve into one connector. This connector can accommodate a choice of inverted bucket, disc, thermostatic wafer, thermostatic, bimetallic or float and thermostatic style Armstrong steam traps. Any other manufacturer s 2-bolt steam trap can also be applied to the Armstrong TVS 4000 Trap Valve Station. Whatever your condensate collection or steam distribution needs, Armstrong has the packaged solution for savings over the long term. Steam Distribution and Collection ASIV Ambient Sensing Isolation Valve Suggested Location Options Steam Supply From Boiler To Condensate Return System To Product Lines Tracers Only Overhead Condensate Return Line CCA-208 Condensate Collection Assembly Spares Service Alley CSDV Condensate Sensing Drain Valve SMSD-8 Steam Distribution Manifold TVS 4000 Trap Valve Station With 2000 Series Inverted Bucket Trap Shown are typical locations for Armstrong manifolds. The many manifolds in refineries and chemical plants consume valuable space and often block movement among the units. Operating costs are high, and installation requires expensive custom fabrication on site. A preassembled manifold with standardized components offers substantial savings over conventional units. Shaded products are available from Armstrong. Call or consult your Armstrong Representative if additional product details are required or visit 3

4 Steam Distribution Manifold (MSD/SMSD) with Piston Sealing Technology As Steam Distribution Assemblies (MSD/SMSD), the manifolds place all steam supply valves in one location. Standardizing components and centralizing their location simplifies installation while providing cost savings. You also save because routine maintenance is faster. Insulation can also be provided and can be a major savings in most installations. Cost Savings Reduced design specification costs Prefabrication vs. field assembly for easy installation Reduced shipping and field handling costs Lower long-term maintenance and operating costs 3-year guarantee Design Flexibility Dimensional consistency Space savings Insulation package available Steam Flow Typical SMSD steam distribution application (shown with optional nipples and TVS 4000 Trap Valve Station) Available with Armstrong s 2000 Series inverted bucket, disc, thermostatic, thermostatic wafer or bimetallic steam traps. Any manufacturer s 2-bolt steam trap can also be applied to Armstrong s trap connectors. See page 8 for piston valve details 4

5 Steam Distribution Manifold (MSD/SMSD) Physical Data MSD Series SMSD Series Model MSD-04 MSD-08 MSD-12 SMSD-04 SMSD-08 SMSD-12 in mm in mm in mm in mm in mm in mm A (Open Position) B Height 11-1/ / / / / /4 743 C CLto CL 6-3/ / / / / /4 120 D Blowdown Connection 3/4 SW 20 3/4 SW 20 3/4 SW 20 3/4 SW 20 3/4 SW 20 3/4 SW 20 E Number of Holes for Mounting (1/2-13 UNC) G Inlet 1-1/2 SW /2 SW /2 SW /2 SW /2 SW /2 SW 40 F Outlet* 1/2 15 1/2 15 1/2 15 1/2 15 1/2 15 1/2 15 Weight lb (kg) 21 (10) 46 (21) 67 (30) 20 (9) 40 (18) 59 (27) Maximum Operating Pressure 464 psi ( F (400 C) *3/4" (20 mm) available contact factory. Steam Distribution Manifold Steam Distribution Manifold with TVS 4000, Inverted Bucket Drip Trap and Optional Stand. List of Materials Name Manifold Body Handwheel Packing Retainer Spring Washer Bolts and Nuts Piston & Stem Valve Sealing Rings Bushing, Valve Material ASTM A105 forged steel Ductile iron ASTM A105 forged steel Stainless steel Bolts: ASTM A193 grade B7 Nuts: ASTM A194 grade 2H 17% Chrome stainless steel Expanded graphite & stainless steel Stainless steel All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 5

6 Pre-Assembled Condensate Collection Assembly (CCA) Armstrong combines its Trap Valve Stations (TVS) with manifolds into a package called the Condensate Collection Assembly (CCA). This prepackaged assembly offers many great benefits cost savings in assembly, design flexibility and reduced purchasing and design time. The CCA with TVS 4000 trap valve station and 2000 Series Inverted Bucket Traps is guaranteed for 3 years. Cost Savings This preassembled concept offers tremendous savings by reducing multiple component purchases that cause additional purchase order monitoring and shipping costs. Other savings include far less labor time required for field assembly. This modular forged steel body design provides quick assembly/delivery, reducing overall project costs. Minimal welding vs complete manifold fabrication Eliminates multiple component purchases Reduced design specification costs Prefabrication vs. field assembly for easy installation Reduced shipping and field handling costs Lower long-term maintenance and operating costs 3-year guarantee Design Flexibility Armstrong can meet virtually any design parameter, including dimensional consistency, with your choice of socketweld or threaded connections. Armstrong inverted bucket, thermostatic, thermostatic wafer, bimetallic or disc steam traps can be provided or any other manufacturer s two-bolt steam trap can be used. If you require a specific piping arrangement, Armstrong can offer the flexibility to meet your specifications. Materials Manifold body: ASTM A105 forged steel Removable Insulation Package A removable insulation package is available for all steam and condensate manifolds. Inexpensive Quick to install Removable for maintenance Reusable after maintenance Weatherproof Formed to cover all manifold elements Strong, durable cover Available to fit all manifold sizes Freeze Protection Package (CCAF) Optional A manifold assembly for more efficient condensate return has another benefit freeze protection. Armstrong s innovative manifold design actually serves as a heat station, heating one or more traps if the steam supply is interrupted or shut off to the traps. The protection is accomplished as long as one trap continues to discharge into the manifold. The manifold s internal syphon tube creates a water seal, which contains the flash steam from the discharge of the live trap. This allows radiant heat to protect shut-off traps from freezing. CCA 212 Condensate Collection Assembly Shown with TVS 4000 Trap Valve Station with 2000 Series Inverted Bucket all stainless steel steam traps with optional removable insulation package including nipples, drain valve and stand.) An optional freeze protection valve package senses condensate temperature. When this device opens, it drains condensate from the manifold assembly, thus providing further freeze protection. 6

7 Pre-Assembled Condensate Collection Assembly (CCA) Physical Data H Model Maximum Allowable Pressure Physical Data H CCAF Condensate Collection Assembly with TVS 4000 Trap Valve Station, Optional Freeze Protection and Drain Valve. Available with Armstrong s inverted bucket, disc, thermostatic, thermostatic wafer or bimetallic steam traps. Any manufacturer s 2-bolt steam trap can also be applied to Armstrong s trap connectors. Model Maximum Allowable Pressure CCA-204 CCA-206 CCA-208 CCA-210 CCA-212 in mm in mm in mm in mm in mm 23-1/ / / /8 1, /8 1, F ( C) CCAF-204 CCAF-206 CCAF-208 CCAF-210 CCAF-212 in mm in mm in mm in mm in mm 27-5/ / /16 1, / /16 1, F ( C) 897 How to Order Manifold Packages CCA Condensate Collection Assembly With IS-2 Connectors with Strainer, Blowdown Valve and Optional Drain Valve Available with Armstrong s inverted bucket, disc, thermostatic, thermostatic wafer or bimetallic steam traps. Any manufacturer s 2-bolt steam trap can also be applied to Armstrong s trap connectors. 1,303 CCA 208 2NPT 6PE 3DVN TVS 4000 SCH80 Manifold Model Number of take-offs per Manifold (2 per level) Connection Size Take-offs, NPS in (mm) Connection Size top, NPS in (mm) Connection Bottom, NPS in (mm) Trap Valve Station 3 MSD Steam Distribution Manifold SMSD Small Steam Distribution Manifold CCA Condensate Collection Assembly CCAF Condensate Collection Assembly Freeze Protection NPT = 1/2 (15) NPTF 1 2SW = 1/2 (15) SW 1 3NPT = 3/4 (20) NPTF 3SW = 3/4 (20) NPTF 6PE = 1-1/2 (40) Plain End 1 6FW150 = 1-1/2 (40) 150# RF Flange 3PE = 3/4 (20) Plain End 1 3NPT = 3/4 (20) NPTM 3FW150 = 3/4 (20) 150# Flange 1. Armstrong stocks manifold cores (less nipples, drain valves, and trap stations) in these connections. 2. Must pick this bottom connection to use Trap station (TVS4000 only choice) and trap on MSD and SMSD. 3. Nipples connecting manifold to trap station can be Schedule 80 (standard) or schedule 160 (optional). 6SW = 1-1/2 (40) SW 1 6FW150 = 1-1/2 (40) 150# RF Flange 6FW300 = 1-1/2 (40) 300# RF Flange 8FW150 = 2 (50) 150# RF Flange 8FW300 = 2 (50) 300# RF Flange 3SW = 3/4 (20) SW 1 3NPT = 3/4 (20) NPTF 3WD = 3/4 (20) Welded Dripleg 2 3TD = 3/4 (20) Threaded Dripleg 2 3NPT = 3/4 (20) NPTM 1 3DVN = 3/4 (20) Drain Valve NPTM/NPTM 3DVS = 3/4 (20) Drain Valve SW/NPTM TVS 4000 IS2 w/bd IS2 Standard None All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 7

8 The Proof Is in the Piston The Piston Valve Armstrong Steam Distribution Manifolds (MSD/SMSD) and TVS 4000 Trap Valve Stations incorporate advanced piston sealing technology for safer, longer lasting steam isolation service. Stem Cap Stainless Steel Valve Plug Disc Springs Graphite and Stainless Steel Valve Sealing Rings Lantern Bushing Open Position Closed Position Dual sealing action. The piston valve is a seatless valve that includes two graphite and stainless steel valve sealing rings that seal the stem and function as a seat. This combination provides long-term protection against leaks to the atmosphere and downstream piping. Self-cleaning action. Stainless steel piston slides without rotating between the two valve sealing rings, preventing dirt from damaging the surfaces. Sealing integrity. Flexible disc springs automatically provide leak tightness by exerting pressure, which keeps the upper and lower valve sealing rings compressed at all times. Sealing tightness is ensured by the compression of the sealing rings against the piston and valve body. This combination of disc springs and dual valve seal rings protects against expansion and contraction due to heating and cooling. This ensures dependable operation, even after years of service. Protected valve stem. The valve stem and sealing surfaces are completely protected from dirt and corrosion by the stem cap, whether in an open or closed position. In-line repairability. All sealing valve components may be easily replaced in-line. Long-term operation. Piston valve design ensures actuation even after many years without operation. 8

9 TVS 4000 Series Stainless Steel Trap Valve Station Integral piston style inlet and outlet isolation valves Armstrong connector adaptable to inverted bucket, disc, thermostatic, thermostatic wafer, bimetallic and float and thermostatic steam traps. Any other manufacturer s 2-bolt steam trap can also be applied to Armstrong s TVS-4000 connector. Connection flexibility (SW, NPT, BST options) 3-year guarantee Test valve used to test and evaluate trap operation Same principle. Different package with two piston-style isolation valves, test valve and integral stainless steel strainer with blowdown valve. What you ll find new are all the benefits of a piston valve integrated into the same space-saving package. Maximum Operating Conditions Maximum allowable pressure: F ( C) Materials TVS 4000 Connector Connector Strainer Screen Test Valve Blowdown Valve Isolation Valve Components All Wetted Parts Valve Sealing Rings Handwheel Weight 6-1/2 lb (2.9 kg) ASTM A351 Gr. CF8M Stainless steel Stainless steel Stainless steel Stainless steel Graphite and stainless steel Ductile iron Reduced costs TVS saves on these fronts: reduced leak points, installation and maintenance time. A full range of features TVS has test and strainer blowdown valves. When installed with Armstrong Model 2011 and 2022 steam traps, it will also accommodate the Armstrong pop drain as well as TrapAlert and SteamEye remote steam trap monitoring and testing devices. Reduced design time Permits combining products with exact face-to-face dimensions. Three-year guarantee The TVS 4000 is guaranteed for three years. Strainer blowdown valve Easy, in-line repairability with maximum safety TVS allows isolation at point of service with upstream/downstream depressurization. Installation versatility The connector design makes the TVS adaptable to any manufacturer s 2-bolt steam trap and piping configuration. Simplified trap testing TVS enhances your capability to check trap operation and offers a built-in method to block and bleed traps. How to Order Model Connection Type of Connection Inlet/Outlet Flow Direction Trap Type TVS /2" NPT R = Right to Left 3/4" SW L = Left to Right BSPT Inverted Bucket Disc Thermostatic Wafer Thermostatic Bimetallic Float and Thermostatic 9

10 Armstrong Universal Stainless Steel Connectors IS-2 Stainless Steel Connector with Integral Strainer Provides: A full line stainless steel strainer in the connector eliminates leak points and reduces installation time A strainer that is not discarded when the trap is replaced Easy strainer screen replacement Optional blowdown valve Accommodates Armstrong s inverted bucket, disc, thermostatic, thermostatic wafer, bimetallic and float and thermostatic traps. Any manufacturer s 2-bolt steam trap can also be applied to Armstrong s IS-2 connector. Maximum Operating Conditions Maximum allowable pressure: F ( C) Connector Styles IS-2 connector with integral strainer IS-2 connector with integral strainer with blowdown valve Connection Sizes 1/2, 3/4, 1 Connection Types Screwed NPT and BSPT Socketweld Flanged (consult factory) How to Order IS-2 Connector with Integral Strainer Specify: Connection style Connection size Connection type Inlet flow direction Left to Right Right to Left Weight 2 lbs (0.91 kg) Materials Connector Body: Strainer: All stainless steel x 20 Mesh 304 stainless steel Standard 360 Stainless Steel Connector Provides: A compact, lightweight assembly Standardization reducing inventory A compact design simplifying piping Accommodates Armstrong s inverted bucket, disc, thermostatic, thermostatic wafer and bimetallic steam traps. Any manufacturer s 2-bolt steam trap can also be applied to Armstrong s standard connector. Maximum Operating Conditions Maximum allowable pressure: F ( C) Connector Styles Standard 360 Materials Connector Body: All stainless steel 304 Connection Sizes 1/2, 3/4 Connection Types Screwed NPT and BSPT Socketweld Flanged (consult factory) How to Order Standard 360 Stainless Steel Connector Specify: Connection size Connection type Weight 1-1/2 lbs (0.70 kg) All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 10

11 2000 Series Inverted Bucket Steam Trap All Stainless Steel For Pressures to 650 psig (45 bar)...capacities to 1,300 lb/hr (590 kg/hr) Description With the 2000 Series you can install inverted bucket efficiency and long service life in any piping configuration with little or no repiping. You get the reliability of the inverted bucket operating principle, plus all the benefits of all-stainless steel construction: A sealed, tamperproof package A compact, lightweight trap The ability to withstand freeze-ups without damage Exceptional corrosion resistance A three-year guarantee against defective materials, and workmanship Series steam traps combine savings in three important areas: energy, installation and replacement. Being mounted on a 360 universal connector provides quick, easy in-line replacement along with all the proven advantages of inverted bucket operation. Maximum Operating Conditions Maximum allowable pressure (vessel design): Model 2010, 2011: F ( C) Model 2022: F ( C) Maximum operating pressure: Model 2010: 200 psig (14 bar) Model 2011: 400 psig (28 bar) Model 2022: F ( C) F ( C) F ( C) Materials Body: Internals: Valve and seat: ASTM-A 240 Grade 304L All stainless steel 304 Hardened chrome steel Options Insu-Pak insulation for Models 2010/2011 Stainless steel pop drain for Models 2011/2022 Probe connection for steam trap monitoring and testing devices for Models 2011/2022 Wiggle wire How to Order 2000 Series Inverted Bucket Steam Traps Specify: Model number Maximum working pressure that will be encountered or orifice size Any options required Select 360 connector style - See pages 9 and 10. For weights and dimensions see Pages 20 and 21. Specification See Page 39. TVS 4000 Trap Valve Station with 2011 Inverted Bucket Steam Trap IS-2 Connector with 2011 Inverted Bucket Steam Trap Standard Connector with 2011 Inverted Bucket Steam Trap All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 11

12 2000 Series Inverted Bucket Steam Trap All Stainless Steel For Pressures to 650 psig (45 bar)...capacities to 1,300 lb/hr (590 kg/hr) Model 2010 Capacity Model 2011 Capacity Model 2022 Capacity *NOTE: Because the orifice is located at the top, inverted bucket steam traps handle dirt and scale better than other types of traps. However, in applications where extremely dirty conditions exist, care should be exercised in the use of all types of restricted-orifice, reduced-capacity traps. For weights and dimensions see Pages 20 and 21. Options Pop Drain for Freeze Protection In general, a properly selected and installed Armstrong trap will not freeze as long as steam is coming to the trap. If the steam supply is shut off, a pop drain should be used to automatically drain the trap. Stainless steel pop drain available for Models 2011 and Maximum Operating Conditions Pressure: 600 psig (41 bar) Temperature: 350 F (177 C) Insu-Pak Now you can insulate the in-line traps in your plant without complicating regular trap maintenance. Insu-Pak, a simple reusable insulation package, cuts the time and cost of in-field installation because it goes on in a snap. And it comes off just as easily. The Insu-Pak can prevent trap freeze-up when used with a properly designed condensate manifold. Designed for use with Models 2010 and Probe connections are available for trap monitoring and testing for Models 2011 and

13 CD-3300 Series Disc Steam Trap All Stainless Steel For Steam Pressures to 450 psig (31 bar) Capacities to 800 lb/hr (363 kg/hr) The Armstrong CD-3300 is a three discharge port design, which provides stable disc operation to extend operating life. The CD-3300 is piped in-line by being mounted on a 360 universal connector, which allows you to install the trap in virtually any piping configuration. Armstrong s 2-bolt connector makes the CD-3300 easy to install and easy to renew. You save on labor time and cost because the connector simplifies piping and remains in-line. Maximum Operating Conditions Maximum operating pressure: F ( C) Maximum allowable pressure (vessel design): F ( C) Materials Trap cap: ASTM A743 CA40 Trap disc: ASTM A276 Gr. 420 Trap body: ASTM A276 Gr. 420 Options Rain guard insulating cap Specification See Page 39. CD-3300 Series Capacity How to Order CD-3300 Series Disc Steam Trap Specify: Model number Any options required Select 360 connector style - See Pages 9 and 10. For weights and dimensions see Page 22. TVS 4000 Trap Valve Station with CD-3300 Series Disc Steam Trap IS-2 Connector with CD-3300 Series Disc Steam Trap Standard Connector with CD-3300 Series Disc Steam Trap 13

14 FT 4000 Series Float and Thermostatic Steam Trap All Stainless Steel For Pressures to 465 psi (32 bar)...capacities to 1,080 lb/hr. (490 kg/hr) Description With the FT 4000 Series, you can install a float and thermostatic trap in any piping configuration with little or no repiping. You get the reliability of the float and thermostatic operating principle, plus all the benefits of all-stainless steel construction. A sealed, tamperproof package A compact, lightweight trap Exceptional corrosion resistance A one-year guarantee against defective materials and workmanship FT 4000 Series Float & Thermostatic steam traps combine savings in three important areas: energy, installation and replacement. Mounting the FT 4000 on universal connectors with integral strainers provides quick, easy in-line replacement with added protection from dirt and scale. Maximum Operating Conditions: Maximum allowable pressure (vessel design) F ( C) Maximum operating pressure: Saturated steam Model FT psig (5 bar) Model FT psig (10 bar) Model FT psig (16 bar) Model FT psig (21 bar) Model FT psig (32 bar) FT 4000 Series Capacity Materials: Body: Internals: Valve and seat: Thermostatic air vent: ASTM A240 Grade 304L All stainless steel-304 Hardened chrome steel Wafer Type-stainless steel with Hastelloy element Specification: See Page 40. How to order FT 4000 Series Float and Thermostatic Steam Traps Specify: Model number Select 360 connector style (IS-2 or TVS 4000) Maximum working pressure that will be encountered or orifice size Any options required For weights and dimensions see Page 23. TVS 4000 Trap Valve Station with FT 4000 Float and Thermostatic Trap IS-2 Connector with FT 4000 Float and Thermostatic Trap 14

15 TT-2000 Series Thermostatic Steam Trap All Stainless Steel For pressures to 300 psig (20 bar) capacities to 3,450 lbs/hr (1,568 kg/hr) The balanced pressure bellows thermostatic steam trap has a sealed, stainless steel body that is lightweight, compact and highly resistant to corrosion. The cage, bellows, valve and seat are all assembled into a precisely calibrated operating unit that ensures positive opening and closing action at slightly below steam temperature. TT-2000 is adaptable to a 360 stainless steel connector to expand piping options and simplify installation. Maximum Operating Conditions Maximum operating pressure: 300 psig (20 bar) Maximum allowable pressure (vessel design): F ( C) Materials Trap cap: Trap body: Bellows: ASTM A L ASTM A240 Stainless steel and bronze with phosphor-bronze bellows, caged in stainless steel Specification See Page 40. How to Order TT-2000 Series Thermostatic Steam Traps Specify: Model number Select 360 connector style - See Pages 9 and 10. Model TT-2000 Series Capacity For weights and dimensions see Page 24. TVS 4000 Trap Valve Station with TT Series Thermostatic Steam Trap IS-2 Connector with TT-2000 Series Thermostatic Steam Trap Standard Connector with TT Series Thermostatic 15

16 WT Series Thermostatic Wafer Steam Trap Stainless Steel For Pressures to 400 psig (28 bar)...cold Water Start-Up Capacities to 1,300 lb/hr (590 kg/hr) Description The WT-2000 thermostatic wafer steam trap is adaptable to a 360 connector to expand piping options and simplify installation. NOTE: Since the normal operation of all suppressed temperaturedischarge (subcooling) steam traps is to back up condensate, they should not be used on drip legs for saturated steam service, heating or process equipment. Exercise care in the maintenance of any thermostatic wafer trap with a small discharge area susceptible to clogging. Maximum Operating Conditions Maximum allowable pressure (vessel design): F ( C) Maximum operating pressure: 400 psig (28 bar) Materials Trap cap: ASTM A L Trap body: ASTM A L Capsule wafer: Hastelloy Capsule body: Stainless Steel 303 Capsule cap: Stainless Steel 303 Specification See Page 40. How to Order WT Series Thermostatic Wafer Steam Trap Specify: Model number Select 360 connector style - See Pages 9 and 10. For weights and dimensions see Page 24. Model WT-Series Thermostatic Wafer Trap Capacity Differential Pressure* Cold Water Start-Up 70 F (21 C) Cold Water Start-Up 212 F (100 C) Operating Condensate 50 F (10 C) Below Saturation psi bar lb/hr kg/hr lb/hr kg/hr **lb/hr **kg/hr , , , , , , , *Capacities based on differential pressure with no back pressure. **Capacities will vary with the degree of subcooling. When greater capacities are required, the trap will automatically adjust to the load, up to the maximum (cold water) capacity shown, by increasing the amount of subcooling. TVS 4000 Trap Valve Station with WT Series Thermostatic Wafer Steam Trap IS-2 Connector with WT Series Thermostatic Wafer Steam Trap Standard Connector with WT Series Thermostatic Wafer Steam Trap 16

17 AB-2000 Bimetallic Steam Trap All Stainless Steel For pressures to 320 psig (22 bar) capacities to 4,630 lbs/hr (2,100 kg/hr) Description Armstrong s AB-2000 Bimetallic Steam Trap operates by the effect that rising temperature has on bimetallic elements. It adjusts itself to changing conditions, as the increasing pressure on the valve is compensated by the curving of the bimetallic elements caused by the increasing temperature. The valve of the AB-2000 is specially treated (boronization) in order to be more resistant to wiredrawing due to erosive condensate flashing. Armstrong s AB-2000 has a sealed, stainless steel body that is lightweight, compact and highly resistant to corrosion. It is adaptable to a Armstrong 360 Universal Connector or a Trap Valve Station (TVS). This makes it easy to install and replace, as the trap can be removed while the connector remains in-line. The result is savings in labor cost and increased flexibility, as other trap types (Inverted Bucket, Thermostatic, Thermostatic Wafer, Disc and Float and Thermostatic) can be installed on the same connector. Valve Boronized The problem of wiredrawing the valve and seat materials is well known to users of steam traps and other types of valves. Wiredrawing is a particular problem with valves and seats in bimetallic traps, which rely on bimetallic elements to operate. To solve the problem of wiredrawing, a new thermochemical surface treatment has been developed. The basic valve material is machinable hardened chrome steel. Atoms of highly resistant material are thermochemically diffused into the valve, giving a layer of protection and a hardness of 1700 HV to the basic material. Because of this new thermochemical treatment, the surface of the valve is highly resistant to the erosive action of flashing condensate. The failure rate of Armstrong bimetallic traps due to wearing out of valve and seat material is greatly reduced. Specification See Page 40. How to Order Specify: Model number Select 360 connector style - See Pages 9 and 10. For weights and dimensions see Page 24. Model AB-2000 Series Capacity Maximum Operating Conditions Maximum allowable pressure (vessel design): F ( C) Maximum operating pressure: 320 psig (22 bar) Maximum back pressure: 99% of inlet pressure Materials Trap cap: Trap Body: Valve: Seat: Elements: Strainer: ASTM A L ASTM A L Chrome steel - 440F, Boronized 303 Stainless steel Nickel plated 304 Stainless steel A = Cold Water B = 72 F (40 C) below saturation C = 36 F (20 C) below saturation D = 18 F (10 C) below saturation TVS 4000 Trap Valve Station with AB Bimetallic Steam Trap IS-2 Connector with AB-2000 Bimetallic Steam Trap Standard Connector with AB-2000 Bimetallic Steam Trap 17

18 SH Series Superheat Traps Bimetallic Steam Traps for Superheat Conditions For pressure to 1,500 psig (104 bar) cold water capacities to 6,500 lb/hr (2,950 kg/hr) Description Armstrong s SH Series Bimetallic Steam Traps for superheat or low load conditions are the ideal traps for applications where other trap styles are not suitable for long life. The Armstrong SH series bimetallic traps also have the ability to handle the large start-up loads associated with superheat applications. The unique bimetallic element allows for shut-off before superheat reaches the trap thus preventing steam loss. The SH 900/1500 series utilizes titanium valves and seats to ensure extremely long service life in the harsh environment of superheated steam systems. Maximum Operating Conditions Maximum allowable pressure (vessel design): SH 250: F ( C) SH 900: F ( C) SH 1500: 1,800 1,050 F ( C) Maximum operating pressure: SH 250: 250 psig (17 bar) SH 900: 900 psig (62 bar) SH 1500: 1,800 psig (124 bar) Suggested minimum operating pressure: SH 250: Not applicable Specification See Page 39 and 40. How to Order SH Series Superheat Traps Specify: Model number Provide maximum operating pressure. Size and type of pipe connection. When flanges are required, specify type of flange in detail. SH 900: 200 psig (14 bar) For weights and dimensions see Page 25. SH 1500: 600 psig (41 bar) Connections SH 250: Screwed, NPT, BSPT, socketweld, flanged SH 900: Socketweld, flanged, buttweld, screwed SH 1500: Socketweld, flanged, buttweld Materials SH 900 Body and cap: ASTM A216 WCB Valve and seat: Boronized stainless steel Elements: Nickel plated Strainer: Stainless steel screen SH 1500 Body and cap: ASTM A351 Gr. CF8M Valve and seat: Titanium Elements: Ni-Cr and stainless steel Strainer: Stainless steel screen SH 250 Body and cap: ASTM 217 Gr. C12A Valve and seat: Titanium Elements: Ni-Cr and stainless steel Strainer: Stainless steel screen 18

19 SH Series Superheat Traps Bimetallic Steam Traps for Superheat Conditions For pressure to 1,500 psig (104 bar) cold water capacities to 6,500 lb/hr (2,950 kg/hr) SH 250/900 Series Pressure/Temperature SH 250/900 Series Cold Water Capacity SH 1500 Series Pressure/Temperature SH 1500 Series Cold Water Capacity 19

20 2000 Series Inverted Bucket Steam Traps Dimensions and Weights Series 2000 Stainless Steel Trap with TVS 4000 Trap Valve Station Series 2000 Stainless Steel Trap with TVS 4000 Trap Valve Station TVS 4000 Series With 2000 Series Inverted Bucket Steam Trap Model Pipe Connections in mm in mm in mm 1/2, 3/4 15, 20 1/2, 3/4 15, 20 1/2, 3/4 15, 20 "A" Trap Diameter 2-11/ / /8 99 "B" Total Height 9-3/ / /2 317 "C" Face to Face 4-3/ / /4 120 "D" Connection C L to Bottom 5-1/ "E" Connection C L to outside of trap 4-13/ / /8 149 "F" Connection C L to front of connector 3-7/ / /8 98 "G" Connection C L to Top 4-1/ / /2 114 "H"Connection C L to bottom of connector 3-1/ / /4 83 "J" Width across handwheels (valve open) 8-3/ / /4 221 Test Port Connection 1/4 NPT 6 1/4 NPT 6 1/4 NPT 6 Trap Only Weight, lb (kg) / /4 2.6 Trap and Connector Weight, lb (kg) / Maximum Operating Pressure (Trap) 200 psi (14 bar) 400 psi (28 bar) 650 psi (45 bar) Maximum Allowable Pressure (Trap) F ( C) F (45 C) All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 20

21 2000 Series Inverted Bucket Steam Traps Dimensions and Weights Series 2000 Stainless Steel Trap with IS-2 Connector with Integral Strainer and Blowdown Valve Series 2000 Stainless Steel Trap With Standard Connector 2000 Series Inverted Bucket Steam Trap With IS-2 Integral Strainer Connector with Blowdown Valve Model Pipe Connections in mm in mm in mm in mm in mm 1/2, 3/4 15, /2, 3/4 15, /2, 3/4 15, "A" Trap Diameter 2-11/ / / / / /8 98 "B" Total Height / /8 219 "C" Face to Face 3-1/ / / "D" Connection C L to Bottom / /8 194 "E" Connection C L to outside of trap 4-5/ / / / / "F" Connection C L to front of connector 7/8 22 7/8 22 7/8 22 7/8 22 7/8 22 7/8 22 "G" Connection C L to Top "H"Connection C L to bottom of connector 2-1/ / / / / /2 64 Trap Only Weight, lb (kg) 3 (1.4) 3-1/4 (1.5) 5-3/4 (2.6) Trap and Connector Weight, lb (kg) 4-1/ / / / Maximum Operating Pressure (Trap) 200 psi (14 bar) 400 psi (28 bar) 650 psi (45 bar) Maximum Allowable Pressure (Trap) F ( C) F *Add 1/2" (15 mm) to B and D dimensions when optional probe connection is required Series Inverted Bucket Steam Trap With Standard Connector Model Pipe Connections in mm in mm in mm 1/2, 3/4 15, 20 1/2, 3/4 15, 20 1/2, 3/4 15, 20 "A" Trap Diameter 2-11/ / /8 99 "B" Total Height / /8 219 "C" Face to Face 2-3/ / /8 60 "D" Connection C to Bottom 4-11/ / /4 185 L "E" Connection C to outside of trap 3-3/ / /4 145 L "F" Connection C to front of connector 13/ / /16 20 L "G" Connection C to Top 1-3/ / /8 46 "H"Connection C to bottom of connector 1-3/ / /8 46 L L Trap Only Weight, lb (kg) / /4 2.6 Trap and Connector Weight, lb (kg) 4-1/ / Maximum Operating Pressure (Trap) 200 psi (14 bar) 400 psi (28 bar) 650 psi (45 bar) Maximum Allowable Pressure (Trap) F ( C) F ( C) All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 21

22 CD-3300 Series Disc Steam Traps Dimensions and Weights Series CD-3300 with TVS 4000 Trap Valve Station Series CD-3300 with IS-2 Connector with Integral Strainer and Blowdown Valve Series CD-3300 with Standard Connector CD-3300 Series Disc Steam Traps CD-3300 Model Standard Connector IS-2 Connector with Integral Strainer TVS 4000 Connector in mm in mm in mm in mm Pipe Connections 1/2, 3/4 15, 20 1/2, 3/4 15, /2, 3/4 15, 20 "A" Trap Diameter 1-1/ / / /2 38 "B" Total Height 2-7/ / / / "C" Face to Face 2-3/ / /4 120 "D" Connection C to Bottom 1-3/ / / /4 83 L L L L L "E" Connection C to outside of trap 3-3/ / / /16 90 "F" Connection C to front of connector 13/ /8 22 7/ /8 98 "G" Connection C to Top 1-3/ /2 114 "H"Connection C to bottom of connector 1-3/ / / /4 83 "J" Width across handwheels (valve open) 8-11/ Test Port Connection 1/4 NPT 6 Trap Only Weight, lb (kg) Trap and Connector Weight, lb (kg) /2 3.8 Maximum Operating Pressure Maximum Allowable Pressure (Vessel Design) 2 (0.91) F ( C) F ( C) All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 22

23 FT 4000 Series Float and Thermostatic Steam Trap Dimensions and Weights Series FT 4000 with TVS 4000 Trap Valve Station Series FT 4000 with IS-2 Connector with Integral Strainer and Blowdown Valve FT 4000 Series Float and Thermostatic Steam Trap FT 4000 Model IS-2 Connector with integral strainer TVS 4000 Connector in mm in mm in mm Pipe Connections 1/2", 3/4" 15, 20 1" 25 1/2", 3/4" 15, 20 "A" Trap Diameter 4-1/ / /2 114 "B" Total Height 5-7/ / /8 198 "C" Face to Face 3-1/ /4 120 "D" Connection C to Bottom 2-5/ / /4 83 L L L L L "E" Connection C to Outside of Trap / /8 250 "F" Connection C to Front of Connector 7/8 22 7/ /8 98 "G" Connection C to Top /2 114 "H" Connection C to Bottom of Connector 2-1/ / /4 83 "J" Width Across Handwheels (valve open) N/A 8-11/ Test Port Connection N/A 1/4 NPT 6 Maximum Operating Pressure (saturated steam) Maximum Allowable Pressure (vessel design) Trap Only Weight, lb (kg) 465 (32 bar) F ( C) 6-1/4 (2.8) Trap and Connector Weight, lb (kg) 8-3/4 (4) 12-3/4 (5.8) All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 23

24 TT-2000/WT-2000/AB-2000 Series Steam Traps Dimensions and Weights Series TT-2000/WT-2000/AB-2000 with TVS 4000 Trap Valve Station Series TT-2000/WT-2000/AB-2000 with Integral Strainer and Blowdown Valve Maximum Operating Conditions TT-2000 Series Thermostatic Trap Maximum allowable pressure (vessel design): F ( C) Maximum operating pressure: 300 psig (20 bar) Maximum operating temperature bellows: 422 F (217 C) WT-2000 Series Thermostatic Wafer Trap Maximum allowable pressure (vessel design): F ( C) Series TT-2000/WT-2000/AB-2000 with Standard Connector Maximum operating pressure: 400 psig (28 bar) AB-2000 Series Bimetallic Trap Maximum allowable pressure (vessel design): F ( C) Maximum operating pressure: 320 psig (22 bar) Maximum back pressure: 99% of inlet pressure TT-2000/WT-2000/AB-2000 Series Steam Traps TT-2000/WT-2000/AB-2000 Model Standard Connector IS-2 Connector with Integral Strainer TVS 4000 Connector in mm in mm in mm in mm Pipe Connections 1/2, 3/4 15, 20 1/2, 3/4 15, /2, 3/4 15, 20 "A" Trap Diameter 2-1/ / / /4 57 "B" Total Height 2-11/ / / / "C" Face to Face 2-3/ / /4 120 "D" Connection C L to Bottom 1-3/ / / /4 83 "E" Connection C L to outside of trap 4-1/ / / /2 115 "F" Connection C L to front of connector 13/ /8 22 7/ /8 98 "G" Connection C L to Top 1-3/ /2 114 "H"Connection C L to bottom of connector 1-3/ / / /4 83 "J" Width across handwheels (valve open) 8-11/ Test Port Connection 1/4 NPT 6 Trap Only Weight, lb (kg) Trap and Connector Weight, lb (kg) 3.2 (7) 1-1/2 (0.70) 3.4 (7.5) 8 (3.6) All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 24

25 SH Series Superheat Traps Dimensions and Weights Model SH 250 Model SH 900 Model SH 1500 SH Series Model SH 250 SH 900 SH 1500 in mm in mm in mm Pipe Connections 1/2, 3/4 15, 20 1/2, 3/4, 1 15, 20, 25 3/4, 1 20, 25 "B" Height 3-1/ / "C" Face-to-Face 3-1/ / /4 158 "D" C L to Top 2-5/ / /16 97 "E" Width 2-3/ / /8 124 *"F" 6-3/ *"G" 6-3/8 162 Weight, lb (kg) 4 (1.7) 10 (4.4) 15 (6.8) *Dimensions for SH 250 "F" are for 3/4" connection, class 150 flanged. Consult factory for dimensions of models with other connection sizes and/or flanges. *Dimensions for SH 900 "F" are for 3/4" connection, class 600 flanged. Consult factory for dimensions of models with other connection sizes and/or flanges. *Dimensions for SH 1500 "F" and "G" are for 3/4" connection, class 1500 flanged. Consult factory for dimensions of models with other connection sizes and/or flanges. All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 25

26 Cost Comparison Worksheet Single Trap Installation - Standard Field Fabricated Installation Standard Trap Instal. Figure 1 Qty. Custom Standard Trap Instal. Qty. Description Assembly Parts and Labor 1/2" 600# Rated Globe or Gate 5 Valves 8 1/2" Sch. 80 Nipples 2 1/2" Line "Tee" 1 1/2" Elbow 1 1/2" Line Strainer 1 1/2" Steam Trap 16 1/2" Welds hrs hrs. Approximate Assembly Time Grand Total Cost Unit Cost Total Cost Figure traps = 5000 valves = 5000 possible stem and body gasket leaks Overall length greater than 30 inches (762 cm) Valve Functions 1 Trap inlet line start-up blowdown valve (visual) 2 Trap inlet isolation valve 3 Trap outlet isolation valve 4 Return line blowdown and test valve (visual) 5 Strainer blowdown valve (visual) Gate and globe valves have exposed rising stems which can corrode and gather dirt which tears stem packing and causes steam leaks. TVS-4000 Armstrong Compact Trap Valve Station TVS 4000 Assembly Components TVS 4000 cast stainless trap valve station Trap inlet piston style isolation valve Trap outlet piston style isolation valve Full port needle style test valve Strainer with blowdown valve * Adaptable to Armstrong 2000 series inverted bucket, disc, thermostatic, thermostatic wafer, bimetallic or float and thermostatic steam traps or any other manufacturer s 2-bolt steam trap. Piston valve has enclosed non-rotating rising stem which protects the stem from corrosion and dirt. 3 year guarantee against defective materials or workmanship. Qty. Unit Cost Total Cost TVS 4000 Overall face to face less than 5 inches (127 mm) 26

27 Cost Comparison Worksheet Standard Field Fabricated Condensate Collection Manifold Stand. Cond. Collec. Instal. Fig. 1 Cust. Stand. Cond. Collec. Instal. Qty. Qty. Description Unit Cost Total Cost Tubular Elements 1 3" Sch. 80, 8 feet pipe 2 3" Caps 1 1-1/2" Branch Welding Fitting 1 3/4" Branch Welding Fitting 8 1/2" Branch Welding Fitting 32 1/2" Sch. 80 Nipples Valves 16 1/2" SW Gate or Globe 8 1/2" Steam Traps 8 1/2" Line Strainers Welding 64 1/2" Nipple Ends 2 3" Caps 8 1/2" Branch Welding Fitting 1 3/4" Branch Welding Fitting 1 1-1/2" Branch Welding Fitting Support Solid Steel or Concrete Labor hrs hrs Approximate Assembly Time Figure 1 Overall length approximately 100 inches (2540 mm) Grand Total Cost Condensate Collection Manifold (CCA) CCA Assembly Components Forged steel body (8) TVS-4000 Trap Valve Stations. Steam traps that can be connected to the TVS 4000 include Armstrong inverted bucket, disc, thermostatic, thermostatic wafer or bimetallic steam traps or any other manufacturer s 2-bolt steam trap (8) 1/2 Sch. 80 nipples Welding / assembly Qty. Unit Cost Total Cost CCA-08 Typical CCA-08 8 Station 27

28 Cost Comparison Worksheet Standard Field Fabricated Tracer Line Steam Supply Manifold Standard Steam Supply Installation Figure 1 Customer's Steam Supply Installation Qty. Qty. Description Unit Cost Total Cost Tubular Elements 1 3" Sch. 80, 8 feet pipe 2 3" caps 1 1-1/2" branch welding fitting 1 3/4" branch welding fitting 8 1/2" branch welding fitting 8 1/2" Sch. 80 nipples Valves 8 1/2" gate or globe Welding 16 1/2" nipples 2 3" caps 8 1/2" branch welding fitting 1 3/4" branch welding fitting 1 1-1/2" branch welding fitting Support Solid steel or concrete Labor hrs hrs Approximate assembly time Figure 1 Overall length approximately 100 inches (2540 mm) Total Cost Steam Distribution Manifold (SMSD) For Tracer Lines SMSD Assembly Components Forged steel body Integral piston style valve 1/2 NPT / SW outlet connection 1/2 SW inlet connection Mounting connections on back of manifold Qty. Unit Cost Total Cost SMSD-08 Typical SMSD-8 8 Station Configuration Overall length approximately 19 inches (483 mm) 28

29 Pump Trap System Applications Flare Header Drain This pump trap system design allows for continuous drainage of hydrocarbon condensation that could result in a liquid slug being sent from low points in the header to the flare. This slug condition can cause water hammer, and potentially extinguish the flare. This system allows customers to run feed lines to an existing flare system even though it may have low points due to elevation changes. Utilization of this pump trap system can eliminate the need for a new flare, or minimize required piping to tie in to an existing system. The liquid drainer installed downstream of the pump prevents hydrocarbon gas flow into the liquid reclamation piping. A process upset could cause an increase in flare header pressure, and create a positive differential. Since the liquid drainer is designed to maintain a liquid seal, it will not discharge process gas, only liquid. A ready source of inert gas, such as nitrogen must be used as the pump trap's motive. As numerous potential gases could be introduced into this system, verification of the lightest specific gravity fluid must be confirmed. Hydrocarbon Knock-Out Drum / Separator Numerous processes in the HPI/CPI industry require liquid removal from a process gas before the next stage of the process can be undertaken. This pump trap application allows for a more cost-effective alternative to explosion proof motors and pumps in a separation area. Typical applications require a small pump to handle very light loads. Verification of the specific gravity of the liquid produced by the separation process is critical. A ready source of inert gas, such as nitrogen, must be used as the pump trap's motive fluid. Process Exchanger with 100% Turndown Capability This pump trap system application allows customers to maintain a totally dry heat exchanger, regardless of the condensate rate that is being produced, or the efficiency of the tube bundle. Variable pressure and condensate rates are common as production demands fluctuate. The elimination of tube bundle corrosion and potential tube failure, causing a production interruption, are the primary benefits of this pump trap system design. Reboilers with excessive surface area commonly run in vacuum due to lower process flow rates produced, and process outlet temperatures required. The pumping trap ensures removal of the condensate against backpressure, which is almost always caused by condensate return lines being overhead. This allows the exchanger to run at it's lowest required pressure, which minimizes energy consumption due to the latent heat content of the lower pressure steam. As the heat exchanger becomes fouled due to coking or the adhesion of burnt product to the tube wall, it becomes less efficient. This mandates the increase of higher temperature / steam pressure from the control valve to accommodate the lack of btu transfer. This scenario typically exceeds the backpressure, creating the need for the downstream trap to stop the flow of steam until condensed. Variable condensate rates and fouled surface areas are "real world" problems that create the opportunity to design a condensate system that performs flawlessly, regardless of the conditions. 29

30 Pump Trap System Applications Vacuum Reboiler / Heat Exchanger Construction Comparison When draining vacuum systems, Net Positive Suction Head [NPSH] is critical for the proper operation of a typical electric condensate pump. The use of pumping traps can minimize the skirt height required for the reboilers or exchangers, which will save thousands of dollars in construction costs. This savings alone can justify the use of this pump trap system. A typical system designed for full vacuum would require a 40 ft. elevation to drain to a conventional condensate pot with level control. This could be reduced to as low as 4 ft depending on the flow rate and head required for the pumping trap system. Flash Tanks As numerous plants utilize a cascading steam system to optimize steam usage, pumping traps offer many advantages for receiving condensate. If electric pumps are used, the height of the flash tank must accommodate NPSH requirements. The typical temperature of medium to low pressure condensate drained from these tanks is also a major concern for cavitation in most electric pumps. The ability of the pump trap to pump condensate at its highest possible temperature, with the flash tank at minimal height, is a great benefit to the user. Steam Turbine Drainage Almost every Refinery and Chemical plant utilizes steam turbines. The vacuum side of the turbine's outlet directly equates to its efficiency. The higher the vacuum, the more efficient it is. Draining the condensate from turbines is critical, as a typical turbine rebuild is very costly. Specially designed pumping trap systems offer more longevity and dependability than conventional steam eductor methods. Eliminating steam consumption of the eductors alone can justify the installation of pumping trap systems. 30

31 PT-300 Series Horizontal Steel, Low Profile Pump Trap The Armstrong PT-300 Series Horizontal, Low Profile pump trap is the low maintenance non-electric solution to move condensate or other liquids from low points, low pressures or vacuum spaces to an area of higher elevation or pressure. Condensate can be returned at temperatures well above the 210 F (99 C) limit of conventional electric condensate pumps without the headaches of leaking seals or cavitation problems. Features Non-electric Uses inexpensive steam, air or gas to operate the pump trap Low profile For tight space requirements High capacity Provides highest capacity in the industry, moving 12 gallons per pump cycle Explosion proof Intrinsically safe ASME code stamped 150/300 psi carbon steel or stainless steel body vessel Low maintenance No leaking seals, impeller or motor problems All stainless steel internals with durable Inconel X-750 springs Externally removable/replaceable seats Valve and seats can be replaced or cleaned without removing pump cap from body PT-300 Pumping Trap Physical Data Model Number PT-308 PT-312 in mm B C D E F G 5-7/ H 21-3/ P 1-5/8 41 R 4-13/ S 5-1/ T U 2-1/4 57 V 7/8 22 W 1-1/4 32 X 1-1/16 27 Face to Face 27-1/2* 698 Weight lb (kg) 154 (70) Number of Body/Cap Bolts 8 Check Valve Conn. in (mm) 2 (50) 3 (75) Stainless Steel Check Valves lb (kg) 15 (7) 38 (17) Maximum Allowable Pressure (Vessel Design): F ( C) standard Maximum Operating Pressure: 125 psig (9 bar) *Tolerance +/- 1/2" Consult Armstrong for engineered pre-piped receiver packages Removable insulation jacket available Reflex gauge glass available Intrinsically safe digital cycle counter available All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 31

32 PT-300 Series Horizontal Steel, Low Profile Pump Trap PT-300 Pumping Trap Materials Name of Part Body and Cap Series PT-300* Fabricated steel 150 psi ASME Sec. VIII design U stamped Compressed non-asbestos SA-449 steel None Stainless steel Stainless steel Zinc plated steel Steel Stainless steel Cap Gasket Bolts Nuts Inlet Valve Assembly Vent Valve Assembly Valve Assembly Washers Plug Mechanism Assembly Springs Inconel X-750 *Series PT-300 is available in all stainless steel. Consult factory. PT-300 Pumping Trap Connection Sizes Horizontal Steel Model PT-308 PT-312 in mm in mm Inlet Connection Outlet Connection Motive Pressure Connection 1/2 15 1/2 15 Vent Connection Optional Gauge Glass Connection 1/2 15 1/2 15 Optional Flanged Connections Available. Consult Factory. Consult Armstrong for engineered pre-piped receiver packages PT-300 Pumping Trap Capacities Motive Pressure Total Lift or Back Pressure Steam Motive PT-308 (12" Fill Head) 2" x 2" Air Motive Steam Motive PT-312 (12" Fill Head) 3" x 2" Air Motive psig bar psig bar lb/hr kg/hr lb/hr kg/hr lb/hr kg/hr lb/hr kg/hr ,900 3,130 9,200 4,173 9,000 4,082 12,300 5, ,200 4,622 10,900 4,944 13,200 5,987 14,200 6, ,600 4,808 11,100 5,035 15,100 6,849 15,800 7, ,800 4,898 11,300 5,126 15,300 6,940 16,100 7, ,200 5,080 * * 15,500 7,031 * * ,600 5,261 * * 16,600 7,530 * * ,000 3,175 10,100 4,581 9,000 4,082 11,200 5, ,600 4,354 10,900 4,944 12,800 5,806 13,800 6, ,750 4,876 11,100 5,035 14,200 6,441 15,000 6, ,900 4,944 * * 14,300 6,486 * * ,300 5,125 * * 15,100 6,849 * * ,100 3,221 9,200 4,173 8,100 3,674 11,500 5, ,300 3,765 10,200 4,627 10,200 4,627 12,750 5, ,100 4,581 11,000 4,989 12,500 5,670 13,500 6, ,200 4,627 * * 12,700 5,761 * * ,300 4,672 * * 13,000 5,897 * * ,700 2,585 7,600 3,447 6,600 2,994 9,800 4, ,600 2,994 8,800 3,992 8,400 3,810 10,500 4, ,600 3,447 10,100 4,581 9,800 4,445 12,700 5, ,400 3,810 * * 10,100 4,581 * * ,400 4,264 * * 10,300 4,672 * * ,500 2,041 7,000 3,175 6,000 2,722 10,200 4, ,700 2,132 7,100 3,221 6,400 2,903 10,400 4, ,400 2,903 * * 7,100 3,221 * * ,600 2,994 * * 7,400 3,357 * * NOTES: Published capacities are based on the use of external check valves supplied by Armstrong. Fill head measured from drain point to top of pump cap. Although motive pressures are shown at high pressure differentials (difference between motive inlet pressure and total lift or back pressure), it is preferable to use a motive pressure of psig ( bar) above discharge (outlet) pressure. This ensures longevity of stainless steel check valves and reduces both venting time and temperature differential (on steam). *Consult factory. PT-300 Capacity Conversion Factors for Other Fill Heads Model Fill Head PT-308 PT-312 in mm in mm in mm in mm in mm NOTES: Fill head is measured from drain point to top of cap. Discharge per cycle is typically 12 gallons for PT-300 Series. All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 32

33 PT-400 Series Vertical Steel Pump Trap The Armstrong PT-400 Series vertical pump trap is the low maintenance, non-electric solution to move condensate or other liquids from low points, low pressures or vacuum spaces to an area of higher elevation or pressure. Condensate can be returned at temperatures well above the 210 F (99 C) limit of conventional electric condensate pumps without the headaches of leaking seals or cavitation problems. Features Non-electric Uses inexpensive steam, air or gas to operate the pump trap Explosion proof Intrinsically safe ASME code stamped 150 psi carbon steel or stainless steel body vessel Low maintenance No leaking seals, impeller or motor problems All stainless steel internals with durable Inconel X-750 springs Externally removable/replaceable seats Valve and seats can be replaced or cleaned without removing pump cap from body PT-400 Pumping Trap Physical Data Model Number PT-404 PT-406 in mm in mm in mm in mm B 17-1/ / / /2 445 C D 19-3/ / / /8 492 G H P 1-5/ / / /8 41 R 9-1/ / / /4 235 T U 2-1/ / / /4 57 Weight lb (kg) Number of Body/ Cap Bolts Check Valve Conn. in (mm) 166 (75) 8 1 (25) 166 (75) 8 1-1/2 (40) 166 (75) 8 2 (50) 166 (75) 8 3 (75) Stainless Steel Check 4 (2) 9 (4) 15 (7) 38 (17) Valves lb (kg) Maximum Allowable Pressure (Vessel Design) F ( C) Standard Maximum Operating Pressure 125 psig (9 bar) Consult Armstrong for engineered pre-piped receiver packages. Removable insulation jacket available Reflex gauge glass available Intrinsically safe digital cycle counter available PT-408 PT-412 All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 33

34 PT-400 Series Vertical Steel Pump Trap PT-400 Pumping Trap Connection Sizes Vertical Steel Model PT-404 PT-406 PT-408 PT-412 in mm in mm in mm in mm Inlet Connection / Outlet Connection / Motive Pressure Connection 1/2 15 1/2 15 1/2 15 1/2 15 Vent Connection Optional Gauge Glass Connection 1/2 15 1/2 15 1/2 15 1/2 15 Optional flanged connections available. Consult factory. PT-400 Pumping Trap Capacities Total Lift PT-406 (12" Fill Head) Motive PT-404 (12" Fill Head) 1" x 1" PT-408 (12" Fill Head) 2" x 2" PT-412 (12" Fill Head) 3" x 2" or Back 1-1/2" x 1-1/2" Pressure Pressure Steam Motive Air Motive Steam Motive Air Motive Steam Motive Air Motive Steam Motive Air Motive psig bar psig bar lb/hr kg/hr lb/hr kg/hr lb/hr kg/hr lb/hr kg/hr lb/hr kg/hr lb/hr kg/hr lb/hr kg/hr lb/hr kg/hr , ,250 1,021 3,100 1,406 3,350 1,520 4,500 2,041 4,850 2,200 7,500 3,402 8,100 3, ,500 1,134 2,650 1,202 4,600 2,086 4,875 2,211 6,600 2,994 7,000 3,175 11,000 4,990 11,650 5, ,100 1,406 3,225 1,463 4,900 2,222 5,100 2,313 7,100 3,220 7,375 3,345 11,700 5,307 12,150 5, ,400 1,542 3,500 1,588 5,200 2,359 5,300 2,404 7,200 3,266 7,400 3,357 12,000 5,443 12,350 5, ,500 1,588 * * 5,400 2,449 * * 7,300 3,311 * * 12,100 5,488 * * ,600 1,633 * * 5,500 2,495 * * 7,400 3,357 * * 12,200 5,534 * * , ,525 1,145 3,500 1,588 4,025 1,826 5,400 2,449 6,200 2,812 7,200 3,266 8,275 3, ,600 1,179 2,800 1,270 4,100 1,860 4,425 2,007 6,300 2,857 6,800 3,084 10,400 4,717 11,250 5, ,800 1,270 2,950 1,338 4,400 1,996 4,750 2,155 6,500 2,948 6,900 3,130 10,800 4,899 11,450 5, ,100 1,406 * * 4,800 2,177 * * 6,700 3,039 * * 11,000 4,990 * * ,200 1,451 * * 4,900 2,222 * * 6,800 3,084 * * 11,200 5,080 * * , ,350 1,066 2,900 1,315 3,425 1,554 4,200 1,905 4,950 2,245 6,900 3,130 8,150 3, ,400 1,088 2,675 1,213 4,000 1,814 4,500 2,041 5,800 2,631 6,400 2,903 9,700 4,400 10,850 4, ,600 1,179 2,800 1,270 4,300 1,950 4,550 2,064 6,000 2,721 6,500 2,948 10,000 4,536 10,900 4, ,800 1,270 * * 4,700 2,132 * * 6,100 2,767 * * 10,200 4,626 * * ,900 1,315 * * 4,800 2,711 * * 6,400 2,903 * * 10,400 4,717 * * , ,350 1,066 3,300 1,451 4,050 1,837 4,350 1,973 5,350 2,427 5,800 2,631 7,125 3, , ,600 1,179 3,600 1,633 4,250 1,927 5,100 2,313 6,000 2,722 6,900 3,130 8,150 3, ,400 1,088 2,675 1,213 4,000 1,814 4,475 2,030 5,700 2,585 6,375 2,892 7,600 3,447 8,500 3, ,500 1,135 * * 4,200 1,905 * * 6,000 2,721 * * 8,100 3,674 * * ,700 1,225 * * 4,500 2,041 * * 6,200 2,612 * * 8,500 3,856 * * , ,400 1,088 3,200 1,451 4,300 1,950 3,800 1,724 5,050 2,291 5,000 2,268 6,650 3, , ,450 1,111 3,500 1,588 4,650 2,109 4,100 1,859 5,175 2,347 5,400 2,450 6,900 3, ,300 1,233 * * 3,700 1,678 * * 4,500 2,041 * * 6,000 2,722 * * ,400 1,088 * * 3,800 1,724 * * 4,800 2,177 * * 6,400 2,903 * * NOTES: Published capacities are based on the use of external check valves supplied by Armstrong. Fill head measured from drain point to top of pump cap. Although motive pressures are shown at high pressure differentials (difference between motive inlet pressure and total lift or back pressure), it is preferable to use a motive pressure of psig ( bar) above discharge (outlet) pressure. This ensures longevity of stainless steel check valves and reduces both venting time and temperature differential (on steam). *Consult factory. PT-400 Series Pumping Trap Materials Name of Part Series PT-400* Body and Cap Fabricated steel 150 psi ASME Sec. VIII design U stamped Cap Gasket Compressed non-asbestos Bolts SA-449 steel Nuts None Inlet Valve Assembly Stainless steel Vent Valve Assembly Stainless steel Valve Assembly Washers Zinc-plated steel Plug Steel Mechanism Assembly Stainless steel Springs Inconel X-750 *Series PT-400 is available in all stainless steel. Consult factory. PT-400 Capacity Conversion Factors for Other Fill Heads in mm in mm in mm in mm in mm Fill Head PT PT Model PT PT NOTES: Fill head is measured from drain point to top of cap. Discharge per cycle is typically 7.8 gallons for PT-400 Series. All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 34

35 PT-516 High Capacity Pump Trap Effective recovery and return of hot condensate are essential to overall plant efficiency while conserving energy. Large amounts of condensate provide the best opportunities to save energy. The Armstrong PT-516 high capacity pump trap is the low maintenance, non-electric solution to moving large amounts of condensate and other liquids from low points, low pressures or vacuum spaces to an area of higher elevation or pressure. Condensate can be returned at temperatures well above the 210 F (99 C) limit of conventional electric pumps without the headaches of leaking seals or cavitation. Features Non-electric Uses inexpensive steam, air or gas to operate the pump trap No leaking seals/packings, impeller wear, electrical or motor problems Reduces maintenance and downtime Single trade installation or repair reduces installation and maintenance costs Direct spring/float actuated mechanism (No maintenance intensive diaphragm operated valve mechanism) Compression spring design Reduces downtime, ensures performance and reliability Rugged stainless steel internals Durable and corrosion resistant for enhanced service life Safety Pump can be placed in flooded pits without fear of electrocution or circuit breaker defaults Explosion proof Standard unit intrinsically safe without additional cost PT-516 High Capacity Pump Trap Physical Data in mm Inlet Connection 4 150# ANSI Flg # ANSI Flg. Outlet Connection 4 150# ANSI Flg # ANSI Flg. Motive Connection 2 NPT 50 NPT Vent Connection 2 NPT 50 NPT Gauge Glass Conn. 1/2 NPT 15 NPT B 62 1,574 C D 19-1/ E F H 48 1,219 P 1-3/4 44 R 8-3/4 222 T U Weight Number of Bolts Maximum Operating Pressure on standard unit: 150 psig (10 bar). Maximum Allowable Pressure (standard vessel design): F ( C). 300 psi (21 bar) vessel available upon request. PT-516 Capacity Conversion Factors for Other Fill Heads Fill Head in mm in mm in mm in mm in mm in mm PT Notes: Fill head is measured from drain point to top of cap. Discharge per cycle is typically 133 gallons. All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice. 35

36 PT-516 High Capacity Pump Trap Typical Applications Low pressure heating systems Process heat exchanger or coils with modulating steam control Remote installations (tracing, tank farms or remote coils) Systems under vacuum Hazardous (explosion proof) areas Caustic environments Sumps or submersed areas Armstrong PT-516 Pump Trap Sizing and Selection PT-516 Pump Trap Capacities Motive Pressure psig bar psig bar lb/hr kg/hr lb/hr kg/hr psig bar psig bar lb/hr kg/hr lb/hr kg/hr ,962 13,137 57,619 26, ,212 13,251 46,238 20, ,162 16,857 61,911 28, ,413 15,156 50,962 23, ,563 19,307 64,738 29, ,672 16,181 53,376 24, ,288 21,903 67,735 30, ,646 17,076 55,418 25, ,214 23,231 69,267 31, ,548 17,485 56,313 25, ,688 24,138 70,562 32, ,454 19,257 60,141 27, ,796 24,855 71,142 32, ,649 20,706 * * ,414 26,950 73,559 33, * * * * ,995 28,575 * * ,210 11,889 41,244 18, ,922 29,902 * * ,353 12,407 44,028 19, ,720 16,656 50,783 23, ,319 12,846 46,382 21, ,611 18,421 54,293 24, ,752 13,042 47,435 21, ,196 20,501 58,013 26, ,555 13,860 51,828 24, ,740 21,655 59,915 27, ,954 14,494 * * ,005 22,682 61,523 27, ,097 15,013 * * ,054 23,159 62,243 28, ,973 11,781 32,026 14, ,675 25,254 65,243 29, ,373 11,963 33,514 15, ,552 27,013 * * ,042 12,720 40,951 18, ,923 28,542 * * ,336 13,307 * * NOTES: Published capacities above are based on actual steam testing using a ,394 13,787 * * minimum 200 F condensate. Published capacities are based on the use of external ,892 10,837 34,893 15,827 check valves supplied by Armstrong ,231 10,991 * * *Consult factory ,570 11,145 * * Application Data Total Lift or Back 4" x 4" Connections 24" Fill Head Pressure Steam Motive Air Motive Motive Pressure 1. Fluid to be pumped: 2. Temperature of fluid to be pumped:! F! C 3. Specific gravity: 4. Required flow rate:! lb/hr! GPM! kg/hr 5. Equipment pressure: a)! Constant! Modulation b) psig Min. to Max. c)! psig! kg/cm 2 6. Distance from condensate outlet nozzle to grade:! Inches! Millimeters 7. Discharge condensate return line size:! Inches! Millimeters 8. Motive gas:! Steam! Air! Gas 9. Motive pressure available:! psig! kg/cm! Other 10. Return line pressure:! psig! kg/cm! Other 11. Vertical lift (H):! Feet! Meters 12. Can pump be vented to atmosphere?! Yes! No 13. Is there a condensate reservoir?! Yes! No If yes, what size? 14. Is reservoir vented?! Yes! No 15. Would you like Armstrong to quote on a packaged pre-piped engineered system?! Yes! No PT-516 High-Capacity Pump Trap Materials Name of Part Description Fabricated steel 150 psi ASME Sec. Vlll design U Cap, Body, Bolting stamp coded Cap Gasket Compressed non-asbestos Inlet Valve Assembly Stainless steel Vent Valve Assembly Stainless steel Mechanism Assembly: Stainless steel Frame, Float and Spring NOTES: 300 psi ASME vessel available upon request. PT-516 available in all stainless steel. Consult factory. Consult factory for engineered pre-piped receiver packages. Removable insulation jackets available Reflex gauge glass available Intrinsically safe digital cycle counter available Total Lift or Back Pressure 4" x 4" Connections 24" Fill Head Steam Motive Air Motive 36

37 PT-300LL/PT-400LL Light Liquid Pump Traps Features Non-electric uses nitrogen or inert gas to operate Explosion proof Intrinsically safe ASME code stamped carbon steel or stainless steel body vessel Low maintenance No leaking seals, impeller or motor problems All stainless steel internals with durable Inconel X-750 springs Externally removable/replaceable seats seats can be replaced or cleaned without removing pump cap from body For specific gravity down to 0.65 Typical Applications Hydrocarbon Knockout Drum/Separator Flare header drain Applications where the specific gravity of the liquid could be as low as 0.65 Applications where hydrocarbons may be present PT-300LL Light Liquid Pump Trap Technical Data Back Pressure Maximum back pressure for the PT-300LL or PT-400LL is 60 psig (4.1 bar) Motive Pressure Maximum motive pressure (Nitrogen or Inert Gas) is 100 psig (6.9 bar) Capacities PT-300LL will discharge approximately 12 gallons (45 liters) per cycle PT-400LL will discharge approximately 7.8 gallons (30 liters) per cycle Note: To determine the lb/hr of liquid being pumped, use the following formula: lb/hr of liquid = capacities x Specific Gravity of liquid To size the Light Liquid Pumps use the sizing charts on pages 32 and 34. PT-400LL Light Liquid Pump Trap Consult Armstrong for engineered pre-piped receiver packages. Hydrocarbon Knock-Out Drum/Separator 37

38 Rescue Cap Non-Electric Steam/Air Powered Pump Retrofit Assembly Do you experience maintenance problems with non-electric steam/air powered pumps? Are you dumping valuable condensate because of frequent maintenance? Do you experience spring failures? Do you have to remove the complete cap assembly to view and inspect the motive or vent valve? Externally replaceable seat assembly Maintenance is a snap with stainless steel seats that can be cleaned or replaced without cap removal. Wear and corrosion resistance Mechanism frame assembly is constructed of rugged investment-cast stainless steel components. Long life and dependable service Simple float/spring operation and rugged all stainless steel construction allow for long, trouble-free service life. Stress chloride corrosion resistance lnconel X-750 springs have higher resistance to the stress that causes lower-grade stainless steel springs to fail. (5 year spring warranty) 38

39 Specifications Condensate Collection Assembly (CCA) The condensate collection assembly shall incorporate a forged steel body (ASTM A105) with a TVS (Trap Valve Station). The TVS connector body shall be of ASTM A351 Gr. CF8M stainless steel. All other wetted parts shall be of stainless steel except the valve sealing rings which shall be a mixture of graphite and stainless steel. The TVS shall incorporate within the connector body inlet and outlet isolation valves, test valve, strainer and strainer blowdown valve, which can also serve as a bleed valve. The integral inlet/outlet isolation valves shall be of piston style using graphite and stainless steel valve sealing rings and stainless steel lantern bushing. The test valve shall be a full port needle style valve of stainless steel. The blowdown valve shall also be a needle style. All (4) valves shall be inline repairable or replaceable. Isolation valves shall be pistonstyle with removable bonnets and completely sealed stem(s) to protect against corrosion. The integral strainer shall be a full line size Y type. Inlet and outlet connections shall be 1/2 (250 mm) NPT or SW type. For compactness, the face to face dimension shall be 4-3/4 (120 mm). The TVS connector shall be a 360 connector able to accept stainless steel inverted bucket, disc, thermostatic, thermostatic wafer, bimetallic or float and thermostatic steam traps by using two bolts to fasten the steam trap of choice to the TVS connector block. The TVS shall be able to perform the functions of isolation of inlet and outlet of the steam trap, test the trap through a full port valve, provide a full line strainer ahead of the trap and provide a blowdown valve on the strainer. The blowdown valve can also function as a bleed valve to depressurize the steam trap prior to removal of the steam trap from the connector. The Trap Valve Station (TVS) shall be Armstrong Model TVS Standard design will be 4, 8 or 12 takeoffs, however, 6, 9 or 10 takeoffs can also be supplied upon request. The Condensate Collection Assembly shall be guaranteed for three years. The Condensate Collection Assembly shall be an Armstrong Model CCA. Steam Distribution Manifold (MSD/SMSD) The steam distribution manifold shall be of forged steel (ASTM A105) design with integral piston style valves, one per takeoff. Standard manifold units will be available in 4, 8 or 12 takeoffs. The takeoffs (outlet connections) will be 1/2 (15 mm) NPT or SW. Typical steam inlet shall be 1-1/2 (40 mm) SW with 3/4 (20 mm) SW blowdown connection. The short steam distribution manifold (SMSD) centerline to centerline dimension between takeoffs will be 4-3/4 (120 mm). The standard steam distribution manifold (MSD) centerline to centerline dimension between takeoffs are 6-3/8 (162 mm). The manifolds shall have two mounting holes 1/2-13 UNC per 4 section assembly. Manifold and valves shall be guaranteed for 3 years. The Steam Distribution Manifold shall be an Armstrong Model MSD/SMSD. Armstrong TVS-4000 Series Stainless Steel Trap Valve Station The TVS connector body shall be of ASTM A351 Gr. CF8M stainless steel. All other wetted parts shall be of stainless steel except the valve sealing rings which shall be a mixture of graphite and stainless steel. The TVS shall incorporate within the connector body an inlet valve, outlet isolation valves, test valve, strainer and strainer blowdown valve, which can also serve as a bleed valve. The integral inlet/outlet isolation valves shall be of piston style using graphite and stainless steel valve sealing rings and stainless steel lantern bushing. The test valve shall be a full port needle style valve of stainless steel. The blowdown valve shall also be a needle style of stainless steel. All (4) valves shall be in-line repairable or replaceable. Isolation valves shall be piston-style with removable bonnets and completely sealed stem(s) to protect against corrosion. The integral strainer shall be a full line size Y type. Inlet and outlet connections shall be 1/2 (15 mm) or 3/4 (20 mm) NPT or SW type. For compactness, the face to face dimension shall be 4-3/4 (120 mm). The Trap Valve Station shall be a 360 universal connector able to accept Armstrong inverted bucket steam trap models 2010, 2011, 2022, disc model CD-3300 and thermostatic wafer model WT-2000, thermostatic model TT-2000, bimetallic model AB-2000 or Float and Thermostatic Model FT The Trap Valve Station (TVS) shall be a model TVS-4000, manufactured by Armstrong International, Inc. Inverted Bucket Trap Steam trap shall be of the inverted bucket type, designed for use with a 360 universal connector or TVS-4000 Trap Valve Station. The entire trap body shall be fabricated from thin wall drawn stainless steel for enhanced freeze resistance. The trap shall employ a simple free-floating valve mechanism with no fixed pivots and no valve or bucket guides. The discharge valve shall be so attached to the valve lever that it is free to rotate for even wear distribution. The trap shall be an Armstrong model 2010, 2011 or Disc Trap Steam trap shall be thermodynamic three discharge port type, designed for use with a 360 universal connector or TVS 4000 trap valve station. The entire trap shall be stainless steel with integral seat design with hardened disc and seating surfaces. The trap shall be an Armstrong model CD Thermostatic Wafer Trap Steam trap shall be thermostatic wafer type designed for use with a 360 universal connector or TVS-4000 Trap Valve Station. The entire trap is fabricated from thin wall drawn stainless steel for enhanced freeze resistance. The trap will be equipped with a Hastelloy capsule wafer. The trap shall be an Armstrong model WT SH 1500 Series Bimetallic Superheat Steam Trap Steam trap shall be an Armstrong bimetallic style. The trap shall be investment cast chrome-moly steel (Model SH 1500) with integral stainless steel strainer, in-line repairable. The mechanism shall consist of a stacked nickel-chrome bimetal operator, with titanium valve and seat. The steam trap shall be capable of operation on low load and superheat applications throughout its pressure/temperature range. 39

40 Specifications (cont.) SH 250/900 Series Bimetallic Superheat Steam Trap Armstrong bimetallic style steam traps in carbon steel (Model SH-250) or stainless steel (Model SH 900) with integral stainless steel strainer, inline repairable. The mechanism shall consist of a stacked nickel-chrome bimetal operator (SH 250 nickel plated) with titanium valve and seat (SH 250 boronized valve and seat). The steam trap shall be capable of operation on low-load applications throughout its pressure/temperature range. Thermostatic Trap Steam trap shall be thermostatic type designed for use with a 360 universal connector or TVS-4000 Trap Valve Station. The entire trap is fabricated from thin wall drawn stainless steel for enhanced freeze resistance. The trap will be equipped with a phosphor bronze bellows caged in stainless steel. The trap shall be an Armstrong model TT AB-2000 Bimetallic Steam Trap Bimetallic steam trap having stainless steel construction with valve boronized and integral strainer. Designed for use on 360 Universal Connectors or TVS 4000 Trap Valve Station. Maximum allowable back pressure is 99% of inlet pressure. The trap shall be an Armstrong Model AB FT 4000 Float and Thermostatic Steam trap shall be float and thermostatic type having stainless steel construction, stainless steel valve, seat and float, for use on a IS-2 connector with integral strainer or TVS-4000 trap valve station. Integral thermostatic element shall be wafer type constructed of Hastelloy and stainless steel. Thermostatic element shall be capable of withstanding 45 F (25 C) of superheat and be resistant to water hammer damage. The trap shall be an Armstrong model FT Pressure Driven Condensate Pump Trap Specifications Armstrong Models PT-308 and PT-312 Body shall be constructed of carbon steel and be ASME Sec. VIII U Stamped to 150 psi. The all stainless steel internal mechanism shall incorporate Inconel X-750 springs for a long service life. Springs made of materials other than Inconel shall not be accepted. Single compression springs shall not be accepted. Motive and vent connections shall have externally replaceable seats for viewing and inspecting the internal valves. Motive force for the pump trap shall be steam, compressed air or inert gas to remove condensate from the receiving vessel. Pumps shall require no electricity for operation. The pump trap shall include a carbon steel water level gauge with shut off valves. Overall height of the pump shall not exceed 28. Condensate inlet and outlet connections on the PT-308 shall be 2 x 2 FNPT and PT-312 shall be 3 x 2 FNPT. 150 lb or 300 lb RF Flanges are available. Check valves shall be stainless steel. Pump trap will be provided with removable insulation cover and digital cycle counter. Manufacturer s standard painting will apply. The trap shall be an Armstrong Model PT-308 or PT-312 pump trap. Armstrong Models PT-404, PT-406, PT-408 and PT-412 Body shall be constructed of carbon steel and be ASME Sec. VIII U Stamped to 150 psi. The all stainless steel internal mechanism shall incorporate Inconel X-750 springs for a long service life. Springs made of materials other than Inconel shall not be accepted. Single compression springs shall not be accepted. Motive and vent connections shall have externally replaceable seats for viewing and inspecting the internal valves. Motive force for the pump trap shall be steam, compressed air or inert gas to remove condensate from the receiving vessel. Pumps shall require no electricity for operation. The pump trap shall include a carbon steel water level gauge with shut off valves. Overall height of the pump shall not exceed 28. Condensate inlet and outlet connections on the PT-404 shall be 1 x 1 FNPT, PT /2 x 1-1/2 FNPT, PT x 2 FNPT, and PT x 2 FNPT. 150 lb or 300 lb RF Flanges are available. Check valves shall be stainless steel. Pump trap will be provided with a removable insulation cover and digital cycle counter. Manufacturer s standard painting will apply. The trap shall be a Armstrong model PT-404, PT-406, PT-408 or PT-412 pump trap. Armstrong Model PT-516 Body shall be constructed of carbon steel and be ASME Sec. VIII U Stamped to 150 psi. The all stainless steel internal mechanism shall incorporate a single Inconel X-750 spring for a long service life. Springs made of materials other than Inconel shall not be accepted. Pilot operated mechanisms shall not be acceptable. Pumps shall require no electricity for operation. Motive force for the pump trap shall be steam, compressed air or inert gas to remove condensate from the receiving vessel. The pump trap shall include a carbon steel water level gauge with shut off valves. Overall height of the pump shall not exceed 48. Condensate inlet and outlet connections on the pump shall be 4 x lb RF flanged. Check valves shall be wafer style carbon steel or stainless steel. Pump trap will be provided with a removable insulation cover and digital cycle counter. Manufacturer s standard painting will apply. The trap shall be a Armstrong model PT-516 pump trap. Armstrong Models PT-300LL and PT-400LL Body shall be constructed of carbon steel (stainless steel upon request) and shall be ASME Sec. VIII U Stamped to 150 psi. The all stainless steel internal mechanism shall incorporate Inconel X-750 springs for a long service life. Springs made of materials other than Inconel shall not be accepted. Single compression springs shall not be accepted. Motive and vent connections shall have externally replaceable seats for viewing and inspecting the internal valves. Motive force for the pump trap shall be Nitrogen or inert gas to remove liquid from the receiving vessel. Pumps shall require no electricity for operation. Liquid inlet and outlet connections on the pump shall be as follows: PT- 300LL shall have either 2 x 2 or 3 x 2 and PT-400LL shall have either 1, 1-1/2, 2 or 3 x 2. Liquid inlet/outlet connections shall be FNPT. 150 lb or 300 lb RF Flanges are available. Check valves shall be stainless steel. Pump trap will be provided with a removable insulation cover and explosion proof digital cycle counter. Manufacturer s standard painting will apply. The trap shall be a Armstrong model PT-300LL or PT-400LL light liquid pump trap. Contact Armstrong for engineered pre-piped packaged receiver systems. 40

41 Steam and Condensate Group Warranties Limited Warranty and Remedy Armstrong International, Inc. ( Armstrong ) warrants to the original user of those products supplied by it and used in the service and in the manner for which they are intended, that such products shall be free from defects in material and workmanship for a period of one (1) year from the date of installation, but not longer than 15 months from the date of shipment from the factory, [unless a Special Warranty Period applies, as listed below]. This warranty does not extend to any product that has been subject to misuse, neglect or alteration after shipment from the Armstrong factory. Except as may be expressly provided in a written agreement between Armstrong and the user, which is signed by both parties, Armstrong DOES NOT MAKE ANY OTHER REPRESENTATIONS OR WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. The sole and exclusive remedy with respect to the above limited warranty or with respect to any other claim relating to the products or to defects or any condition or use of the products supplied by Armstrong, however caused, and whether such claim is based upon warranty, contract, negligence, strict liability, or any other basis or theory, is limited to Armstrong s repair or replacement of the part or product, excluding any labor or any other cost to remove or install said part or product, or at Armstrong s option, to repayment of the purchase price. As a condition of enforcing any rights or remedies relating to Armstrong products, notice of any warranty or other claim relating to the products must be given in writing to Armstrong: (i) within 30 days of last day of the applicable warranty period, or (ii) within 30 days of the date of the manifestation of the condition or occurrence giving rise to the claim, whichever is earlier. IN NO EVENT SHALL ARMSTRONG BE LIABLE FOR SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, LOSS OF USE OR PROFITS OR INTERRUPTION OF BUSINESS. The Limited Warranty and Remedy terms herein apply notwithstanding any contrary terms in any purchase order or form submitted or issued by any user, purchaser, or third party and all such contrary terms shall be deemed rejected by Armstrong. Special Warranty Periods are as follows: Stainless Steel Product Series 2000 Three (3) years after installation, but not longer than 30 months after shipment from Armstrong s factory. Limited Warranty and Remedy Armstrong Fluid Handling, Inc. ( Armstrong ) warrants to the original user of those products supplied by it and used in the service and in the manner for which they are intended, that such products shall be free from defects in material and workmanship for a period of one (1) year from the date of installation, but not longer than 15 months from the date of shipment from the factory. This warranty does not extend to any product that has been subject to misuse, neglect or alteration after shipment from the Armstrong factory. Except as may be expressly provided in a written agreement between Armstrong and the user, which is signed by both parties, Armstrong DOES NOT MAKE ANY OTHER REPRESENTATIONS OR WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. The sole and exclusive remedy with respect to the above limited warranty or with respect to any other claim relating to the products or to defects or any condition or use of the products supplied by Armstrong, however caused, and whether such claim is based upon warranty, contract, negligence, strict liability, or any other basis or theory, is limited to Armstrong s repair or replacement of the part or product, excluding any labor or any other cost to remove or install said part or product, or at Armstrong s option, to repayment of the purchase price. As a condition of enforcing any rights or remedies relating to Armstrong products, notice of any warranty or other claim relating to the products must be given in writing to Armstrong: (i) within 30 days of last day of the applicable warranty period, or (ii) within 30 days of the date of the manifestation of the condition or occurrence giving rise to the claim, whichever is earlier. IN NO EVENT SHALL ARMSTRONG BE LIABLE FOR SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, LOSS OF USE OR PROFITS OR INTERRUPTION OF BUSINESS. The Limited Warranty and Remedy terms herein apply notwithstanding any contrary terms in any purchase order or form submitted or issued by any user, purchaser, or third party and all such contrary terms shall be deemed rejected by Armstrong. 41

42 What is it? SteamStar is the first and only web-based platform for recording, monitoring and managing steam trap information. SteamStar web-based platform can.. Reach company energy conservation goals. The use of SteamStar facilitates company wide awareness of performance toward steam saving goals through the web-based sharing of information. The awareness and accountability established by the web- based platform fosters cost saving activities; these activities can be measured against company and industry best practice performances. Improve Steam System Efficiency. Steam system efficiency can be directly linked to how well the system is managed. SteamStar provides diagnostic reporting at various levels of organizational responsibility. The reports permit the evaluation of current conditions and provide the knowledge necessary to make money saving decisions. Achieve Best Practice Energy Management goals. History has shown that companies maximize sustainable cost savings when energy goals are measured, monitored, and managed on a consistent basis. SteamStar is the web based tool that will bring data together by site, by region and by company to help achieve best practice energy management goals. Save valuable time. Typically steam trap data is presented from multiple sites in different software formats and with different qualifying terminology. These variables make managing steam system information difficult and time consuming. SteamStar offers a platform for company wide steam data to be viewed and analyzed without wasted time. Improve company wide communication. Users at the plant level can perform evaluations to determine root causes of steam system issues. Using the same platform, the global energy manager has the ability to analyze data for sites around the world. This level of communication promotes understanding of steam system efficiency. Reduce implementation conflicts. Data from 3rd party software or Microsoft Excel can be import to the SteamStar platform. This feature makes SteamStar a non-binding platform designed for easy company wide usage. Eliminate costs associated with software licensing agreements. Licensing agreements can cost ten s of thousands of dollars for initial software purchase. For the software to facilitate multiple user, additional capital outlay is required. The web-based platform of SteamStar eliminates licensing fees and dramatically reduces the required investment. A one month return on investment! Contact Armstrong for an on-line demonstration of SteamStar at the following address: steamstar@armstrong-intl.com 42

43 SteamStar web-based platform will. Evaluate Steam System Data Detailed analysis of all site surveys can be evaluated using the many standard reports available on SteamStar. The executive summary highlights total site energy losses and current steam trap failures. This report is critical in establishing a base line for future achievement of company energy goals. Other standard reports are: Steam and Monetary Loss Defective Trap Report Manufacturer Summary Trap Evaluation by Application Steam management not only helps to mitigate steam losses but it also facilitates educated decisions about the type of technology used. All of the standard reporting capabilities of SteamStar provide a site with actionable data in a user friendly format. Work Order Report The work order report is a premium report that was designed for optimum facility payback on labor and material while keeping energy losses to a minimum. This report is available at the site or unit level and will create a work order for steam trap repairs based on payback. A facility with dedicated, trained personnel for steam trap maintenance is very rare. Quick determination of areas losing the most money is invaluable when trying to allocate labor for various important facility activities. Work Order Report Benchmark A premium report that establishes a comparison to sister sites and industry peer best practices. The user has a choice of which sites to benchmark and which factors to compare. Steam losses and monetary losses can be compared by site, by type of application, by type of trap, and more. This report will offer management a wide analysis of which sites are working to reduce steam losses and which lag behind. It will also highlight any areas of concern in terms of high steam trap failure rate compared to total monetary losses. This report is a valuable tool for facility mangers and global energy managers alike. Trend The premium trend analysis report will assist a manager with the comparison of multiple years of data. The data available for comparison is steam loss, monetary loss, fuel consumed, and emissions created. Like the other premium reports, the trend analysis report can be compared by site and or region. This report will emphasize sites or units that are actively pursuing company best practice goals for steam system management. It will also track emissions; CO2, SOx, NOx, and highlight the progress made toward steam system efficiency and dollars saved. Emission Report The premium emission report is valuable for its ability to focus on the quantifiable emissions of CO2, SOx, and NOx in one summarized view. Steam system efficiency is not only viewed as important in terms of energy losses but also in terms of environmental impact. The emission report is especially beneficial to users who are penalized by world governments for high emission factors. Contact Armstrong for an on-line demonstration of SteamStar at the following address: steamstar@armstrong-intl.com 43

44 Additional Products for the Hydrocarbon and Chemical Processing Industries Washdown Equipment Steamix hose stations from Armstrong offer a maximum temperature rise set point and cold water failure shutdown for ultimate user safety. Armstrong hot and cold water hose stations include a thermostatic mixing valve for optimum flexibility, control and safety for applications where there is a central hot water supply. Liquid Drainers Armstrong float type drain traps are designed for draining heavy liquids from gases or light liquids (dual gravity drainers). These liquid drainers can operate to 3,700 psig or specific gravity down to BiMetallic Superheat Steam Traps SH Series Bimetallic Steam Traps adjust automatically to changing conditions. The SH Series can operate at pressures to ,050 F and is capable of operation on low load applications. Available in carbon steel or stainless steel. Inline repairable. Tank Heaters Armstrong tank heaters are built to withstand the rigorous demands encountered in industrial installations. The heavy-duty features of our units were developed in response to a need for tank heaters that could provide efficient heat transfer without sacrificing structural integrity. Steam-A-Ware Steam-A-ware sizing and selection for steam, air and hot water systems. Includes steam traps, pressure reducing valves, control valves, temperature regulators,water heaters and condensate pumps of various types, sizes and configurations for any application. Easy-to-use Steam-A-ware allows you to store multiple product specifications in a schedule and access Armstrong s library of materials from the CD or the Web. For more than 100 years in the steam business, Armstrong has been devoted to building stronger bonds through the sharing of information and ideas. That s why Knowledge Not Shared Is Energy Wasted is our motto, promise and pledge to you. And it s why we founded Armstrong Steam University. Use this site for quick research on steam, answers to steam system questions and comprehensive online steam system education. Bulletin 290-B 6/05 Armstrong Steam and Condensate Group, 816 Maple St., Three Rivers, MI USA Phone: (269) Fax: (269)

Hydrocarbon & Chemical Processing Solutions

Hydrocarbon & Chemical Processing Solutions Hydrocarbon & Chemical Processing Solutions Table of Contents Armstrong Packaged Piping Solutions...3-4 Steam Distribution Manifolds (MSD/SMSD) & Cost Comparison Worksheet...5-7 Condensate Collection Assembly

More information

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries Bulletin 290-C Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries Packaged Piping Solutions - Steam Distribution Manifolds - Condensate Collection Assemblies - Trap

More information

STAINLESS STEEL TRAP VALVE STATION

STAINLESS STEEL TRAP VALVE STATION STAINLESS STEEL TRAP VALVE STATION MAKES A LONG STORY... 36 [914 MM]...SHORT. 4.75 [121 MM] THE INNOVATION IS INTEGRATION Armstrong stainless steel Trap Valve Station (TVS) reduces your costs for installation,

More information

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260 SERIES 40/40D AND C250/260 Designed for a variety of high pressure and high capacity applications found in utility, industrial and marine service FEATURES Designed to fail open. Designed for superheat

More information

THERMOSTATIC STEAM TRAPS

THERMOSTATIC STEAM TRAPS THERMOSTATIC STEAM TRAPS Nicholson is the originator of the bellows actuated Thermostatic Steam. Nicholson s thermostatic product range spans applications from critical tracing to high capacity process.

More information

SECTION Pipeline Ancillaries

SECTION Pipeline Ancillaries SECTION Pipeline Ancillaries ARMSTRONG PRODUCT CATALOGUE 380 Strainers STY085 Y strainer. Suitable for steam, water, air, gas and most non corrosive chemicals Body & cap: Bronze B-62 Strainer: 304 stainless

More information

CD-33/CD-33S Controlled Disc Steam Traps

CD-33/CD-33S Controlled Disc Steam Traps D-33/D-33S ontrolled Disc Adapts to outdoors Optional rain guard insulating cap available to prevent excessive radiant heat loss in outside applications. Extended life Three discharge port design offers

More information

Yarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3

Yarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3 Wide range of steam traps that provide consistent performance in less than perfect conditions Features 1 1 Thermostatic Traps Repairable Pressure assisted fail-open design Freeze proof Easy to check cyclic

More information

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime.

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime. Armstrong Mini Pump Bulletin AFH-223 The Armstrong mini pump trap is the smallest non-electric solution that can move condensate or other liuids from lower to higher points and from lower to higher pressures.

More information

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need. A wide range of process thermostatic steam traps is available to match almost any application need. FEATURES Simple construction Easy to maintain as installed Excellent air handling capability Pressure

More information

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to HOW TO ORDER page. PT5 Thermodynamic Steam Traps MATERIAL : No. PART MATERIAL QTY. (Nos.). BODY ASTM A743 Gr. CA 40 0 (Seat Hardened) (Cast Equiv. AISI 420) 2. DISC CAP ASTM A743 Gr. CA 40 0 (Cast Equiv. AISI 420) 3. DISC

More information

The right trap for the right application.

The right trap for the right application. The right trap for the right application. Whenever you re faced with a process application, it s not enough to just select any steam trap to solve your problem. Instead, remember to match your application

More information

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S SERIES PB, 29, 129Y AND 29S Economical and simplified solutions that offer quality and optimum steam trap service FEATURES 29S 29 Thermostatic traps Pressure assisted fail-open design Freeze proof Easy

More information

LIQUIDATOR UMT-TD Series Thermodynamic

LIQUIDATOR UMT-TD Series Thermodynamic 52 LIQUIDATOR UMT-TD Series Thermodynamic Applications Steam Trap Unit Heaters Steam Tracing Drip Legs Tire Presses Laundry Equipment Plating Tanks Platen Presses Cooking Equipment Pressures To 450 PSIG

More information

THE THERMOSTATIC STEAM TRAP

THE THERMOSTATIC STEAM TRAP THE THERMOSTATIC STEAM TRAP The purpose of any steam trap is to discharge, promptly, all condensate (as well as air and other non-condensible gases) without discharging live steam. Since steam is a vapor

More information

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5 A wide range of process thermostatic steam traps is available to match almost any application need FEATURES Simple construction Easy to maintain as installed Excellent air handling capability Pressure

More information

THERMODYNAMIC STEAM TRAPS

THERMODYNAMIC STEAM TRAPS THERMODYNAMIC STEAM TRAPS Nicholson has a wide variety of Thermodynamic Steam Traps to accommodate applications through 600 psi. Most models utilize Nicholson s exclusive Celtron Cartridge. The Celtron

More information

Economical and simplified solutions that offer quality and optimum steam trap service.

Economical and simplified solutions that offer quality and optimum steam trap service. Economical and simplified solutions that offer quality and optimum steam trap service. It All Comes Down To Protection Regardless of the temperature and pressure characteristics of steam line drips or

More information

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107 TABLE OF CONTENTS FLOAT AND THERMOSTATIC SERIES PAGE How to Select All 107 C 14 H 8 I 12 X 14 Competitive Changeover 18 THERMOSTATIC 8C 22 9C 2 17C 20 Competitive Changeover 17C 24 Replacement Modules

More information

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS THERMODYNAMIC S has a wide variety of Thermodynamic Steam Traps to accommodate applications through 600 psi. Most models utilize s exclusive Celtron Cartridge. The Celtron facilitates inline maintenance

More information

Liquid Drainers LIQUID DRAINERS

Liquid Drainers LIQUID DRAINERS Liquid Drainers 206 Liquid Drainers Model/Series Type Body Material PMO Sizes Connection Page No. (PSIG) WLDE Float Ductile Iron 200 1 1 /2, 2, 2 1 /2 NPT WLDES Float Cast Steel 300 2 1 /2 NPT, SW, FLG

More information

UNIVERSAL STYLE STEAM TRAPS WU450 Series

UNIVERSAL STYLE STEAM TRAPS WU450 Series Watson McDaniel reserves the 2010 Watson McDaniel Company UNIVERSL STYLE STEM TRPS WU450 Series Universal Connectors for Universal Steam s STEM TRPS Model WU450, WU450S, WU450SB WU450S-LR, WU450SB-LR,

More information

Yarway Narvik Steam Desuperheater Series 4300 TempLow

Yarway Narvik Steam Desuperheater Series 4300 TempLow For precise and economical control of steam temperature Features and benefits Easy installation Installation in straight, vertical or horizontal pipe. Minimal headroom is required for mounting Only standard

More information

PIP PNE00004 Steam Trap Guidelines

PIP PNE00004 Steam Trap Guidelines July 2016 Piping PIP PNE00004 Steam Trap Guidelines PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities, this Practice has been prepared from

More information

LIQUIDATOR 450 SERIES

LIQUIDATOR 450 SERIES LIQUIDATOR 450 UMT SERIES TRAP AND UMTC CONNECTOR APPLICATIONS Unit Heaters Steam Tracing Drip Legs Tire Presses Cooking Equipment Laundry Equipment Plating Tanks Platen Presses Air Vents OPTIONS SLR -

More information

Hoffman Specialty General Catalog

Hoffman Specialty General Catalog Hoffman Specialty General Catalog HS-900E ESP-PLUSTM For computer aided selection of Steam Trap and Regulators, please refer to the Steam Specialty Component Selectors in the Hoffman Specialty website

More information

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual Armstrong J Series, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual This bulletin should be used by experienced personnel as a guide to the installation

More information

THERMODYNAMIC STEAM TRAPS

THERMODYNAMIC STEAM TRAPS 53 STEAM TRAPS has a wide variety of Thermodynamic Steam Traps to accommodate applications through 600 psi. Most models utilize s exclusive Celtron Cartridge. The Celtron facilitates inline maintenance

More information

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel: www.watsonmcdaniel.com 428 Jones Boulevard Limerick Airport Business Center Pottstown PA 19464 Tel: 610-495-5131 129 Return Introduction Return System Shown below is a simplified view of a steam system

More information

Steam Traps and Steam Specialties

Steam Traps and Steam Specialties Steam Traps and Steam Specialties The new shape in steam traps... Bestobell s Delta Element A sophisticated, yet simple, design that will provide years of trouble-free service with no live steam loss.

More information

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS STEAM TRAPS Steam Traps Steam Trap Model * Sizes 3/4, 1, 1 1 /2, 2, 3, 4 Connections NPT, SW, FLG Body Material Carbon Steel or 316SS Options Live Orifice Air Vent PMO Max. Operating Pressure 450 PSIG

More information

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM:

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM: BEST PRACTICE NO. 51 THE PRESSURIZED CONDENSATE RECOVERY SYSTEM: the solution to increasing a steam system s thermal cycle efficiency Pressurized condensate systems can provide plants with a minimum of

More information

Bringing Energy Down to Earth

Bringing Energy Down to Earth Bringing Energy Down to Earth Say energy. Think environment. And vice versa. Any company that is energy conscious is also environmentally conscious. Less energy consumed means less waste, fewer emissions

More information

Our Know-How. Your Peace of Mind. Steam Solutions

Our Know-How. Your Peace of Mind. Steam Solutions Our Know-How. Your Peace of Mind. Steam Solutions Steam Solution Know-How Our team of specialists have years of experience in planning and engineering. This knowledge, combined with our valuable manufacturer

More information

Product. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits

Product. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits Engineering Products for the Steam Industry Since 985 Product Catalog Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits Add Efficiency To Your Steam Investment...

More information

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service. Steam and Condensate Technology Solutions which are brilliant in their simplicity combined with a first-class design & consultancy service. Steam Traps The Free Float - Principle Free Float Steam Traps

More information

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS Inverted Float & Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS ABOUT US In 1916, the company, then known as the Sterling Engineering Company, began designing and manufacturing valves, traps, strainers

More information

STEAM CONSERVATION GUIDELINES

STEAM CONSERVATION GUIDELINES STEAM CONSERVATION GUIDELINES FOR CONDENSATE DRAINAGE Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. CG-1 Table

More information

Installation and Testing of Inverted Bucket Steam Traps Manual

Installation and Testing of Inverted Bucket Steam Traps Manual Installation and Testing of Inverted Bucket Steam Traps Manual 307-EN Please read and save these instructions Armstrong IB Traps Installation Before Installing Run pipe to trap. Before installing the trap,

More information

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment Inverted ucket Steam Traps for efficient condensate drainage of industrial and HVC equipment Inverted ucket steam traps The proper drainage of condensate is essential to efficient steam system operation.

More information

Chapter 2.3: Steam System

Chapter 2.3: Steam System Part I: Objective type Questions and Answers Chapter 2.3: Steam System 1. For industrial process heating, the best quality of steam is: a) dry saturated steam b) superheated steam c) wet steam d) high

More information

Disc Type Steam Trap TSD-42

Disc Type Steam Trap TSD-42 Disc Type TSD-42 TSD-42 is disc type steam trap for high pressure (maximum pressure: 4.2 MPa). It is compact and lightweight, and can be installed horizontally or vertically. Disc Ring By-Metal Valve seat

More information

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL Essex County College - West Essex Campus Addition And Renovations dib # 54292 / 11-14 SECTION 232116 - HYDRONIC PIPING SPECIALTIES PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions

More information

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment Float & Thermostatic Steam Traps from Spirax Sarco About float & thermostatic steam traps Most

More information

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series Pamphlet A2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment

More information

Intelligent System Solutions Steam Air Hot Water

Intelligent System Solutions Steam Air Hot Water Intelligent System Solutions Steam Air Hot Water Featured Products Trap Valve Station and Associated Traps Steam System Testing and Monitoring The TVS 4000 Series Stainless Steel Trap Valve Station enhances

More information

Steam Conservation Guidelines for Condensate Drainage Steam Trap Sizing and Selection.

Steam Conservation Guidelines for Condensate Drainage Steam Trap Sizing and Selection. Handbook P-101 Steam Conservation Guidelines for Condensate Drainage Steam Trap Sizing and Selection. Table of Contents Recommendation Charts and Instructions for Use...CG-2 Steam Tables...CG-3 Steam...Basic

More information

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D Technical Data SD 9902D SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 PRINTED IN U.S.A. SD 79902D/9803 Condensate Commander Pump Dimensions Weight Size A B C D E* F Lbs. 1"x

More information

STEAM TRAPS

STEAM TRAPS STEAM TRAPS 08.2016 info@ayvaz.com www.ayvaz.com SELECTION OF STEAM TRAPS In order to get maximum efficiency and service life from the steam lines and steam related systems, it is crucial to make the correct

More information

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils Installation, Operation and Maintenance Guide Steam Coil Installation, Operation and Maintenance Guidelines for the installation, operation and maintenance of the Heatcraft brand of steam heating coils

More information

Steam Conservation Guidelines for. Drainage. Mead O'Brien (800) LP Steam. Condensate. HP Steam RECEIVER TANK HEATER

Steam Conservation Guidelines for. Drainage. Mead O'Brien (800) LP Steam. Condensate. HP Steam RECEIVER TANK HEATER HP Steam Steam Conservation Guidelines for Condensate Drainage LP Steam RECEIVER TANK HEATER RECEIVER PUMP HP Condensate Return Table of Contents Recommendation Charts and Instructions for Use...CG-2 Steam

More information

Installation and Maintenance "L" and "LS" Series

Installation and Maintenance L and LS Series Installation and Maintenance "L" and "LS" Series IB-43-E This bulletin should be used by experienced personnel as a guide to the installation and maintenance of "L" and "LS" Series ultra capacity float

More information

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle Steam Trap Presentation for IDEA Distribution Workshop Presenter: Joe Radle Proper Piping when Reducing Pipe Size Concentric reducer Eccentric reducer Correct Wrong Typical Steam Main Drip Station D Size

More information

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM BEST PRACTICE NO. 30 WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM Air and noncondensable gases are one of the major problems in a steam system that can cause production

More information

Air Vents AV-392. Proven Same proven, free-floating all stainless steel mechanism as used in Armstrong steam traps.

Air Vents AV-392. Proven Same proven, free-floating all stainless steel mechanism as used in Armstrong steam traps. Proven Same proven, free-floating all stainless steel mechanism as used in Armstrong steam traps. Leak-tight Positive closing, free-floating stainless steel lever ensures leak-tight closing under all conditions.

More information

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual 111-EN SH-300 SH-900 SH-1500 SH-1600 SH-1700 Table of Content. General Safety Information. 3 Product

More information

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000 SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual 65 SH-2500 SH-2000 AB-3000 Table of Contents General Safety Information.............. 2 Product Information..................3

More information

ESCO. Committed. Group of Companies. to help conserve Steam Energy

ESCO. Committed. Group of Companies. to help conserve Steam Energy Group of Companies Committed to help conserve Steam Energy Company Profile Group of Industries was established in 1977 as an Energy Conservation as well as Industrial Equipments manufacturing Company concentrating

More information

Boiler Steam Supply Piping Basics November 18, ) Q: What kind of condensate traps should be used on vacuum condensate return systems?

Boiler Steam Supply Piping Basics November 18, ) Q: What kind of condensate traps should be used on vacuum condensate return systems? Boiler Steam Supply Piping Basics November 18, 2015 1) Q: What kind of condensate traps should be used on vacuum condensate return systems? A: What is often used in a vacuum system is a thermodynamic disc

More information

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass Product of Quality Best Performance Ball Float Controlled Steam Traps Auto Drain Traps Float Valve Air Vent Valves Feed Control Valve Drain Control Valve Thermo Dynamic(TD) Trap Safety Valve Condensate

More information

Series 1140 and 1141 Temperature Regulators

Series 1140 and 1141 Temperature Regulators Hoffman Specialty Installation & Maintenance Instructions HS-504(E) Series 1140 and 1141 Temperature Regulators! CAUTION FOLLOW ALL INSTALLATION AND OPERATING INSTRUCTIONS. TURN OFF WATER OR STEAM BEFORE

More information

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions 138-EN Please read and save these instructions Contents General Safety Information... 3 Product Information...3-5 Product

More information

D-8 OUTLINE SPECIFICATION FOR HTHW HEAT EXCHANGERS

D-8 OUTLINE SPECIFICATION FOR HTHW HEAT EXCHANGERS D-8 OUTLINE SPECIFICATION FOR HTHW HEAT EXCHANGERS GENERAL: This document provides performance requirements and guideline information for Heat Exchanger equipment for Colorado College only, and is not

More information

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series Pamphlet M2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment

More information

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Catalog. Self-operated Regulators Volume 2 Temperature Regulators Catalog Self-operated Regulators Volume 2 Temperature Regulators Self-operated Regulators Temperature Regulators Volume 2 Catalog 2012 Overview Self-operated Temperature Regulators 5 Self-operated Pressure

More information

Pump & Trap Combinations

Pump & Trap Combinations NON-ELECTRIC CONDENSATE Pump & Trap Combinations Why use a Pump-Trap? Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company

More information

How to Trap: Trap Selection and Safety Factors

How to Trap: Trap Selection and Safety Factors How to Trap: Trap Selection and Safety Factors Bringing Energy Down to Earth Say energy. Think environment. And vice versa. Any company that is energy conscious is also environmentally conscious. Less

More information

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings. SECTION 15481 COMPRESSED AIR SYSTEM PART 1 - GENERAL 1.1 SECTION INCLUDES A. Pipe and pipe fittings, including valves, unions and couplings. B. Air compressor. C. After cooler. D. Refrigerated air dryer.

More information

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series Pamphlet U2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment

More information

Jet Compressors. Circulate Steam Boost Low-Pressure Steam Compress and Mix Gases in Desired Proportion

Jet Compressors. Circulate Steam Boost Low-Pressure Steam Compress and Mix Gases in Desired Proportion s Circulate Steam Boost Low- Steam Compress and Mix Gases in Desired Proportion S&K s are used in the process, paper, petroleum, power, gas, and other industries to circulate steam, boost low-pressure

More information

HEAT GENERATION 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods

HEAT GENERATION 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods 230520 HEAT GENERATION Cornell s Design and Construction Standards provide mandatory design constraints and acceptable or required products for all construction at Cornell University. These standards are

More information

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat s s Function Level control valves control liquid levels without the necessity of an external energy input. There are two types of level controllers including:. Chambered valves such as; bleeding & venting

More information

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

ICS Float and Thermostatic Steam Trap Installation and Operation Manual ICS Float and Thermostatic Steam Trap Installation and Operation Manual 59 Table of Contents. General Safety Information. 3 Product Information. 4 Product Installation. 5 Service and Maintenance. 6 Troubleshooting.

More information

SECTION METERS AND GAGES FOR PLUMBING PIPING

SECTION METERS AND GAGES FOR PLUMBING PIPING SECTION 220519 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Pure Performance For Steam Mains and Tracers

Pure Performance For Steam Mains and Tracers Pamphlet A2004-2 Thermodynamic Steam Traps P Series FP Series HR Series Pure Performance For Steam Mains and Tracers Are you looking for Improved Performance? Disc traps are valued for their compact size

More information

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers. SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

MFP14 Automatic pumps for condensate and other industrial fluids

MFP14 Automatic pumps for condensate and other industrial fluids MFP14 Automatic pumps for condensate and other industrial fluids Effective condensate management... an essential part of any steam plant If energy requirements are to be kept to a minimum, then efficient

More information

VS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL

VS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL VS SERIES NH3 STEAM VAPORIZERS Revised March 1997 OPERATION MANUAL CONTENTS PAGE 1. GENERAL................................... 1 Figure 1-1 - VS Series Vaporizer......................... B How to Select

More information

Why steam trap survey?

Why steam trap survey? Why steam trap survey? Why does our customer need to have a steam trap survey regularly? Leaking steam trap wasting steam away steam boiler keep producing steam that will be wasted away Blocked steam trap

More information

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT Technical Data SD 4511A SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 TYPE T14 & T14D TEMPERATURE PILOT PRINTED IN U.S.A. SD 4511A/9811 5 13 /16 D 4 7 /8 1 13 /16 T14 PILOT

More information

Wide range of steam traps that provide consistent performance in less than perfect conditions.

Wide range of steam traps that provide consistent performance in less than perfect conditions. Wide range of steam traps that provide consistent performance in less than perfect conditions. It ll omes Down To Protection Regardless of the temperature and pressure characteristics of steam line drips

More information

How to Trap: Installation and Testing

How to Trap: Installation and Testing How to Trap: Installation and Testing 1 Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. Bringing Energy Down

More information

Documento Descargado desde:

Documento Descargado desde: Documento Descargado desde: WWW.VAPORISA.CL Pumping Traps Inside Advantages Mechanical condensate pumps operate with a spring-assisted float mechanism, which means the springs themselves are a major wear

More information

Removal of Non-condensable Gases and Air Is Critical In A Steam System

Removal of Non-condensable Gases and Air Is Critical In A Steam System Removal of Non-condensable Gases and Air Is Critical In A Steam System Air and non-condensable gases are one of the major problems in a steam system. Both can cause production problems for a steam system

More information

13-1. Temperature Regulator

13-1. Temperature Regulator -1 Step 0 Type/Structure/Features Please refer to this for type, structure and features of. Step 1 Selection Please look at the ID chart to choose the right products depending on the intended uses. Details

More information

High Capacity Instantaneous Steam Fired Water Heater

High Capacity Instantaneous Steam Fired Water Heater MODEL F High Capacity Instantaneous Steam Fired Water Heater Features Compact High Capacity Design Packaged System Water heater is factory assembled on an all welded steel mounting frame to save time and

More information

Silhouette. Feedwater Heater. Boiler Feedwater

Silhouette. Feedwater Heater. Boiler Feedwater Roth Roth Low Low Silhouette Silhouette TRAY DEAERATORS Boiler Boiler Feedwater Feedwater Heater Heater Capacities Capacities to to 50,000 50,000 lb/hr lb/hr Model RDTV-150-5-1-2 vertical tray type deaerator

More information

D-11 OUTLINE SPECIFICATION FOR HTHW (ABOVE GRADE) HYDRONIC PIPING

D-11 OUTLINE SPECIFICATION FOR HTHW (ABOVE GRADE) HYDRONIC PIPING D-11 OUTLINE SPECIFICATION FOR HTHW (ABOVE GRADE) HYDRONIC PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES SECTION 23 23 00 REFRIGERANT PIPING AND SPECIALITIES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Refrigerant piping. 2. Unions, flanges, and couplings. 3. Pipe hangers and supports. 4. Refrigerant

More information

How to Trap: Steam Tracer Lines

How to Trap: Steam Tracer Lines How to Trap: Steam Tracer Lines 1 Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. Bringing Energy Down to Earth

More information

A M E M B E R O F T H E K E N D A L L G R O U P

A M E M B E R O F T H E K E N D A L L G R O U P A M E M B E R O F T H E K E N D A L L G R O U P Presented by: Dan Gallagher Energy Opportunities in a Steam System What makes up your Steam System Boiler Room Distribution System Mechanical Rooms Point

More information

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI Hydraulic Institute Standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards Date Description of Change Pages / Sections Modified ID 6/15/16 Entire document - mgl44 PART 1 - INTRODUCTION 1.1 PURPOSE A. This section is intended to define the general installation and minimum product

More information

MFP14 Automatic pumps. for condensate and other industrial fluids

MFP14 Automatic pumps. for condensate and other industrial fluids MFP1 Automatic pumps for condensate and other industrial fluids Effective condensate management... an essential part of any steam plant If energy requirements are to be kept to a minimum, then efficient

More information

Flo-Rite-Temp Instantaneous Steam/Water Heater

Flo-Rite-Temp Instantaneous Steam/Water Heater Steam/Water Heaters Steam/water heaters are typically classified as instantaneous, semi-instantaneous and tank-type. Temperature control can be defined as either feed-forward or feedback. Feedback systems

More information

Pumps. Pressured-powered pump catalog. The more reliable and efficient way to pump condensate and other liquids.

Pumps. Pressured-powered pump catalog. The more reliable and efficient way to pump condensate and other liquids. Liqui-Mover Pumps Pressured-powered pump catalog The more reliable and efficient way to pump condensate and other liquids. Liqui-Mover Pumps Efficiently and effectively draining condensate from steam equipment

More information

SECTION STEAM AND STEAM CONDENSATE SPECIALTIES

SECTION STEAM AND STEAM CONDENSATE SPECIALTIES SECTION 23 22 18 STEAM AND STEAM CONDENSATE SPECIALTIES PART 1 - GENERAL 1.1 SECTION INCLUDES A. Steam Traps. B. Flash Tanks. C. Condensate Return Units. D. Pressure Reducing Valves. E. Safety Valves.

More information

Water Fuel + Air for combustion Blowdown

Water Fuel + Air for combustion Blowdown Water 1. Going through a water treatment system 2. Condensate is re-used & will be mixed with fresh water in deaerator 3. Mixture of this water is sent to a heat exchanger inside the boiler chimney (Economizer)

More information

SECTION AIR COMPRESSORS AND ACCESSORIES

SECTION AIR COMPRESSORS AND ACCESSORIES PART 1 GENERAL 1.01 WORK INCLUDED SECTION 11370 AIR COMPRESSORS AND ACCESSORIES A. This specification includes air compressors with air dryers. B. Furnish, install, start-up, and test air compressors and

More information