Hot Melt Material Applicator MC 6

Size: px
Start display at page:

Download "Hot Melt Material Applicator MC 6"

Transcription

1 Hot Melt Material Applicator Manual P/N D English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY

2 Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation publication which is protected by copyright. Original copyright date No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Nordson Corporation. The information contained in this publication is subject to change without notice. Trademarks AccuJet, AquaGuard, Asymtek, Automove, Autotech, Blue Box, CF, CanWorks, Century, Clean Coat, CleanSleeve, CleanSpray, Compumelt, Control Coat, Cross-Cut, Cyclo-Kinetic, Dispensejet, DispenseMate, Durafiber, Durasystem, Easy Coat, Easymove Plus, Econo-Coat, EPREG, ETI, Excel 2000, Flex-O-Coat, FlexiCoat, Flexi-Spray, Flow Sentry, Fluidmove, FoamMelt, FoamMix, Helix, Horizon, Hose Mole, Hot Shot, Hot Stitch, Isocoil, Isocore, Iso-Flo, JR, KB30, Little Squirt, Magnastatic, MEG, Meltex, MicroSet, Millenium, Mini Squirt, Moist-Cure, Mountaingate, MultiScan, Nordson, OmniScan, Opticoat, Package of Values, Pattern View, PluraFoam, Porous Coat, PowderGrid, Powderware, Pro-Flo, ProLink, Pro-Meter, Pro-Stream, PRX, RBX, Rhino, S. design stylized, Saturn, SC5, Select Charge, Select Coat, Select Cure, Slautterback, Smart-Coat, Spray Squirt, Spraymelt, Super Squirt, Sure Coat, System Sentry, Tela-Therm, Trends, Tribomatic, UniScan, UpTime, Veritec, Versa-Coat, Versa-Screen, Versa-Spray, Watermark, When you expect more. are registered trademarks of Nordson Corporation. ATS, Aerocharge, Auto-Flo, AutoScan, BetterBook, Chameleon, CanNeck, Check Mate, COLORMAX, Control Weave, Controlled Fiberization, CPX, E-Nordson, EasyClean, Eclipse, Equi=Bead, Fillmaster, Gluie, Ink-Dot, Iso-Flex, Kinetix, Maxima, MicroFin, Minimeter, Multifil, OptiMix, PluraMix, Primarc, Prism, Process Sentry, PurTech, Pulse Spray, Seal Sentry, Select Series, Sensomatic, Shaftshield, Spectral, Spectrum, Sure Brand, Swirl Coat, Vista, Walcom, 2 Rings (Design) are trademarks of Nordson Corporation. Designations and trademarks stated in this document may be brands that, when used by third parties for their own purposes, could lead to violation of the owners rights. COV_EN_403022D

3 Table of Contents I Table of Contents Section 1 Safety Separate document Section 2 Description 1. Intended Use Area of Use (EMC) Use Limitation Unintended Use Examples Residual Risks Operating Manual Series Overview Explanation of Unit Description Configuration Code Example Code and Keys Unit Components Functioning Melting Process and Hot Melt Material Supply Motor Gear Pump Safety Valve (Option) Heating and Temperature Control Undertemperature Locking Device Overtemperature indication / shutdown Temperature Setback Inert Gas Equipment

4 II Table of Contents Section 2 Description (contd.) 8. Electrical Cabinet Front/Rear Side Main Switch Button Heating On/Off Temperature Controller Channel assignment Push button Temperature Setback Buttons Motor Start/Stop Torque Setting Dial Button Purge Lighted Symbol Inert Gas Bottle Empty Lighted Symbol Inert Gas Supply Electrical Cabinet Aeration Door Locks Protective Panels ID Plate Section 3 Installation 1. Transport Lifting (Unpacked Unit) Unpacking Removing Storage Disposal Setting Up Overview Exhausting Hot Melt Material Vapors Electrical Connections Laying Cables Line Voltage External Motor Release

5 Table of Contents III Section 3 Installation (contd.) 10. Connecting Inert gas Installing Heated Hoses Connecting Disconnecting Relieving Pressure Second Open jawed Wrench Section 4 Operation 1. Filling the Tank Maximum Filling Level Opening and Closing Tank Opening Tank Closing Tank Tank Hood Switch Operating Elements Setting Temperatures General Values Setting Inert Gas Control Setting Adhesive Output Quantity Without Pressure Control Valve With Pressure Control Valve (Option) Initial Startup Daily Switch ON/OFF Daily Switch ON Daily Switch OFF (Inert Gas also Off) Daily Switch OFF (Inert Gas not Off) Emergency Switch OFF Settings Record Form Section 5 Maintenance 1. Relieving Pressure Daily Maintenance Regular Maintenance External Cleaning

6 IV Table of Contents Section 5 Maintenance (contd.) 5. Inspection for External Damage Electrical Cabinet Fan Maintenance Changing Hot Melt Material Type Flushing with a Cleaning Agent Maintenance Record Form Section 6 Troubleshooting 1. Temperature Controller Helpful Tips Safety Valve Indication Lamps Troubleshooting Tables Only the White Indication Lamp is Lit Red Indication Lamp is Lit Unit does not Function One Channel (Heating Zone) does not Heat No Hot Melt Material (Motor does not Rotate) No Hot Melt Material (Motor Rotating) Not Enough Hot Melt Material Hot Melt Material Pressure Too High Hot Melt Material Pressure Too Low Hot Melt Material Residues in Tank Hot Melt Material Hardens in Tank Section 7 Specifications 1. General Data Temperature Electrical Data Dimensions and Weights Section 8 Index

7 Section 1 Safety Observe and follow all safety instructions, the general safety instructions included as a separate document, as well as the specific safety instructions in all other related documentation.

8 1-0 Safety

9 Section 2 Description

10 2-0 Description

11 Description 2-1 Section 2 Description 1. Intended Use Hot melt material applicators of the series may only be used to melt and feed polyurethane hot melt materials (PUR). Any other use is considered as not intended and is carried out at the operator s own risk. Nordson will not be responsible for personal injury or equipment damage resulting from unintended use. Intended use also includes the observance of Nordson safety instructions. Nordson recommends collecting detailed information about the materials to be used. Area of Use (EMC) The units are designed for use in industrial areas (see also included Declaration of Conformity). Use Limitation When used in residential and commercial areas, the units can cause interference in other appliances, e.g. radios. Unintended Use Examples The unit may not be used under the following conditions: In defective condition When unapproved changes or modifications have been made by the customer Without heat protection and protective panels With electrical cabinet door open With tank lid open With tank hood open In an explosive atmosphere When the values stated under Specifications are not complied with. The unit may not be used to melt and process the following materials: Explosive and flammable materials Erosive and corrosive materials Foodstuffs.

12 2-2 Description 2. Residual Risks The unit is designed to protect operating personnel from possible risks. However, some residual risks cannot be avoided. Personnel must consider the following: Risk of burns from hot melt material Risk of burns on the tank lid after the tank hood has been opened Risk of burns when filling the tank Risk of burns from heated accessories such as heated hoses or hot melt application heads Inhalation of potentially hazardous hot melt material vapors. 3. Operating Manual Representative for all units of this series, this manual describes a unit with one gear pump and one hose connection. The position numbers in the illustrations do not correspond to the position numbers in the technical drawings or spare parts lists. The functions Automatic temperature setback when motor has been off for 60 minutes and Piston pump control, described in the separate manual Temperature Controller, are not available on this unit. The safety valve is referred to as bypass or bypass valve in Nordson manuals. It is used as a pressure control valve in this unit.

13 Description Series Overview Unit Motors / Pumps Hose connections per pump -1x x2 1 2 Explanation of Unit Description The description is illustrated by the example -1x2. -1x2 2 hose connections per pump 1 motor / pump Series description / 6 liter tank capacity Description Nordson units of the Meltex product line which process polyurethane hot melt material. M = Moisture C = Curing 5. Configuration Code The configuration code is stamped into the ID plate. The code consists of all positions, whereby a function or component that is not available is replaced with an X (Refer to Example). Example Position Code M C 6 1 x 1 C F 1 / X Code and Keys The chart shows all possible configurations. Unit des signa natio on tion Con nfigu urat Position Code Key Note 1 M Series or unit designation M = Moisture 2 C Series or unit designation C = Curing 3 6 Series or unit designation 6 = 6 liter tank capacity One pump 6 x 7 1 One hose connection per pump 2 Two hose connections per pump 8 C Operating voltage 3x400 V AC Temperature sensor Fe-CuNi Fe-CuNi = FE/KO G Operating voltage 3x230 V AC Temperature sensor Fe-CuNi Fe-CuNi = FE/KO V Operating voltage 3x400 V AC Temperature sensor Ni 120 Y Operating voltage 3x230 V AC Temperature sensor Ni F Pump PR 12m2 with VX-non-stick coating 10 1 Hose connection 5 / 16 in. = 8 mm 11 / 12 F Safety valve (Pressure control valve) Option

14 2-4 Description 6. Unit Components Figure 2 1 shows the essential unit components. Details can be found in the technical drawings (Refer to Spare Parts Lists) MCSY339L168B0697 Fig Tank hood switch 2. Tank hood 3. Tank hood handle 4. Electrical cabinet 5. Motor 6. Coupling 7. Gear pump 8. Screw on stopper 9. Tank 10. Cable guides 11. Hose connection fitting 12. Protective panels 13. Tank lid handle 14. Tank lid lock 15. Tank lid 16. Tank hood bracket 17. Tank lid detent 18. Inert gas equipment 19. Safety valve plate (option) 20. Safety valve (option) Feet 23. Unit frame 24. Motor cover 25. Heat protection

15 Description Functioning The functioning of the unit is described here. The operation of the individual components is described in the manual for the component (refer to Index of Documentation). Melting Process and Hot Melt Material Supply The adhesive is placed in the tank. There it is heated to the processing temperature stated by the manufacturer or to the temperature set by the user. The melted material flows to the gear pump. The gear pump driven by a motor feeds the material to the hose connection fitting. From here the material flows through the heated hose to the hot melt material application head or to the hot melt material handgun. Motor The motor (in this case a torque motor) drives the gear pump (also refer to manual Motor). NOTE: Torque motors function in a special way. They do not run constantly at a set speed; instead their purpose is to supply torque at standstill or at any partial speed. In practice this means that the motor comes to a standstill when the nozzle of an adhesive application head is closed and begins operation again when the nozzle is opened. Because of this, the safety valve that is standard on Nordson adhesive application units is not part of this unit (also refer to Safety Valve [Option] ). NOTE: The motor is first ready for operation when the undertemperature locking device has been released or when the unit has almost reached the set nominal value temperature. NOTE: The motor can also be turned on/off externally (refer to section Installation and Wiring Diagram). Gear Pump The gear pump, which is driven by a motor, feeds the adhesive to the hose connection fitting or to the unit outlet (also refer to manual Gear Pump). NOTE: Nordson gear pumps may not be operated without hot melt material. Before switching on the motor, make sure the tank is filled. Safety Valve (Option) This unit is equipped with a torque motor. Thus for technical reasons a safety valve is not necessary. On this unit the optional safety valve serves as a pressure control valve for setting and stabilizing the desired adhesive pressure. NOTE: The lead sealing described in the manual Safety Valve is omitted when the safety valve is used as a pressure control valve.

16 2-6 Description Heating and Temperature Control The melting zone is heated with cast in heating elements. They provide optimal heat conduction and energy utilization. The temperature is measured by sensors and regulated electronically by the temperature controller. Undertemperature Locking Device The undertemperature locking device prevents the unit or system from starting up when the hot melt material is too cold. It is activated until the nominal temperature value minus undertemperature value has been exceeded. On initial heating of the unit, the locking device is first released when the actual temperature is 3 C below the nominal value temperature. The undertemperature locking device locks the motors, solenoid valves and, in some cases, other components of the hot melt material application system. Refer to the wiring diagram to determine which components are locked. Overtemperature indication / shutdown The independently operating overtemperature shutdown mechanisms protect the unit and adhesive from overheating. For overtemperature shutdown, the heating and motor are switched off. The red indication lamp collective fault lights up. Overtemperature indication through temperature controller: Switches relay output collective fault when setpoint temperature value plus overtemperature value has been reached and the red indication lamp lights up. The unit remains ready for operation. Overtemperature shutdown through temperature controller: The overtemperature shutdown value is set automatically 30 C above the highest temperature setpoint value. Overtemperature shutdown through thermostat(s): Serves as an emergency switch OFF in case the overtemperature shutdown of the temperature controller does not function properly. Refer to section Specification for shutdown value. NOTE: Depending on the adhesive used, the overtemperature thermostats of the tank and possibly of the optional can receptacle may need to be adapted to the maximum processing temperature of the adhesive (This may mean that the overtemperature thermostats have need to be replaced). However, the switchoff value of the thermostat may not exceed the max. operating temperature of the unit! For thermostats see section Specifications. WARNING: When the overtemperature shutdown is triggered, there is either a fault in settings or unit malfunction. Switch off the unit and have the fault eliminated by qualified personnel. Temperature Setback Serves to protect the hot melt material and save energy during interruptions in production or work stoppages. Setback value and setback period are adjustable.

17 Description 2-7 Inert Gas Equipment See also manual Inert Gas Equipment and manual Temperature Controllers. CAUTION: Use only suitable inert gas. Refer to the Material Safety Data Sheet of the material or contact the material supplier. The inert gas prevents the material in the tank from reacting with humidity. It displaces the air in the tank and thus protects the material from an undesired reaction which may cause the material to harden sooner than it should. Inert gases are e.g. nitrogen (N) and carbon dioxide (CO 2 ). The advantage of carbon dioxide is that it is heavier than air and literally floats on top of the material in the tank. NOTE: A diaphragm compressed air dryer, including preceding high performance compressed air filter, for conditioning compressed air such that it can be used as inert gas, can be purchased from Nordson. The inert gas supply is carried out: Automatically during operation as set on the Control System (inert gas injection interval and duration of injection). Automatically after the tank hood is closed. The duration of injection can be set on a timer relay. Manually by pressing the Purge button as an additional Inert gas flush, e.g. when the tank has been filled. An empty gas bottle is indicated by the lighted symbol Inert gas bottle empty. CAUTION: When the main switch is set to 0/OFF, the inert gas equipment is turned off and the tank is deaerated. This can lead to hardening of the adhesive in the tank (Also refer to Daily Shutdown).

18 2-8 Description 8. Electrical Cabinet WARNING: Risk of electric shock. Failure to observe can result in personal injury, death and/or equipment damage. Front/Rear Side MCPA039L151A0397 Fig Main switch 2. Temperature controller 3. Air filter 4. Push button Heater off 5. Push button Heater on 6. Lighted symbol Inert gas injection 7. Push button Purge (Inert gas flush) 8. lluminated symbol Inert gas bottle empty 9. Torque setting dial 10. Push button Motor Start 11. Push button Motor Stop 12. Push button Temperature setback 13. Door locks 14. Electrical cabinet fan with filter 15. Dummy plate 16. Connection socket heated hose

19 Description 2-9 Main Switch (1, Fig. 2-2) Serves to switch the unit On/Off. Position 0/OFF = unit is switched off. Position I/ON = unit is switched on. The main switch can be secured with padlocks against unauthorized switching. CAUTION: When the main switch is set to 0/OFF, the inert gas equipment is turned off and the tank is deaerated. This could cause hardening of the adhesive in the tank (Refer also to Daily Shutdown). NOTE: The heater or the load current circuit must also be turned on. This is done by pressing the push button Heating on. Button Heating On/Off (4 and 5, Fig. 2-2) The buttons switch the heating (load current circuit) on or off. Temperature Controller (2, Fig. 2-2) For operation see manual Temperature Controllers. Channel assignment Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 Channel 9 Tank (melt zone) Heated hose Application head Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Push button Temperature Setback (12, Fig. 2-2) Serves to turn on/off the temperature setback. The temperature setback function protects the adhesive and saves energy during breaks. The setback temperature and time can be set (Refer to manual Temperature Controllers).

20 2-10 Description Buttons Motor Start/Stop (10 and 11, Fig. 2-2) Used to turn on/off the motor. Bu the motor can not be turned on until the unit is ready for operation or until the green lamp in the temperature controller lights up. NOTE: The motor can also be turned on/off externally (Refer to Installation, External Motor Release and Wiring Diagram). NOTE: Do not operate Nordson gear pumps without adhesive. Ensure that the tank is filled before turning on the motor. Torque Setting Dial (9, Fig. 2-2) Serves to set the torque or the adhesive output quantity within the range of 0 to 100 %. The selected setting should be locked in to avoid accidental resetting. Button Purge (7, Fig. 2-2) Pressing the button activates an additional Inert gas flush, e.g. after the tank has been filled. Lighted Symbol Inert Gas Bottle Empty (8, Fig. 2-2) Lights when the inert gas bottle is empty. Lighted Symbol Inert Gas Supply (6, Fig. 2-2) Lights each time inert gas is injected. Electrical Cabinet Aeration (3 and 14, Fig. 2-2) Serves to aerate the electrical cabinet, which reduces the inside temperature. The filter must be cleaned or replaced regularly (Refer to Section 5 Maintenance). Door Locks (13, Fig. 2-2) The electrical cabinet can be opened with the aid of the included key. Store the key such that it is accessible only to qualified and authorized personnel. WARNING: Allow only qualified and authorized personnel to open the electrical cabinet. WARNING: Disconnect equipment from the line voltage.

21 Description Protective Panels WARNING: Do not operate unit without protective panels. The protective panels may be removed for installation, maintenance, etc. The panel locks (panel fasteners) are unlocked with the included square wrench. MCSY333S050A0397 Fig ID Plate The ID plate contains the following information: Code Nordson Engineering GmbH D Lüneburg Germany R P/N Ser. U I A f V 50/60 Hz P W Pmax W XXSY015L034A0395 Fig. 2-4 Information Description Unit Code Unit description and configuration code P/N Article number Ser. Serial number U Operating voltage Volt I Fuse rating Ampere f Frequency of line voltage Hertz P Power consumption of the unit Watt P max Power consumption of the unit and connected accessories Watt

22 2-12 Description

23 Section 3 Installation

24 3-0 Installation

25 Installation 3-1 Section 3 Installation WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation. 1. Transport See Section Specifications for weight. Only use suitable methods of transport. Protect the unit from humidity, excessive dust, impacts and vibrations. Lifting (Unpacked Unit) See section Specifications for weight. Lift at the unit frame using suitable lifting equipment or a forklift. 2. Unpacking Unpack the unit carefully and check for damage caused during transport. Recycle packing materials or dispose of properly according to local regulations. 3. Removing Empty unit completely and rinse thoroughly with cleaning agent (Refer to Maintenance). Then disconnect all connections to the unit and allow the unit to cool. 4. Storage Do not store the unit in the open! Protect the unit from humidity, excessive dust and great fluctuations in temperature (forming of condensation). 5. Disposal Ensure proper disposal of the unit according to local regulations.

26 3-2 Installation 6. Setting Up Set up the unit only in surroundings which correspond to its Degree of Protection (see section Specifications). Do not set up in explosive surroundings! Protect the unit against vibrations. Remove transport protection devices (if any). Provide enough space for unit to be easily accessible (Fig. 3-1). MCSY332S070A0397 Fig Overview NOTE: The overview does not replace the following description. Exhaust hot melt material vapors if necessary (can only escape when the tank lid is open) Electrical connections Connect inert gas Install heated hose MCSY336L110B0697 Fig Exhausting Hot Melt Material Vapors Make sure that hot melt material vapors do not exceed the prescribed limits. Exhaust the vapors if necessary. Provide sufficient ventilation in the area where the machine is set up.

27 Installation Electrical Connections WARNING: Risk of electrical shock. Failure to observe can result in personal injury, death or equipment damage. Laying Cables Make sure that cables do not come into contact with any rotating and/or heated unit components. Do not pinch cables and check regularly for damage. Replace damaged cables immediately! The unit is equipped with cable guides for laying cables (1, Fig. 3-3) MCSY334S065B0779 Fig. 3-3 Line Voltage WARNING: The unit may only be operated with the line voltage indicated on the ID plate. NOTE: Permissible tolerances regarding the rated line voltage are +5% / 10%. The mains connection cable must have a cross section matching the rated power consumption. See ID plate for rated current. The mains terminals are located in the electrical cabinet. See Wiring Diagram for connection allocation. External Motor Release The motor can also be turned on/off externally. The contacts External motor release were bridged by the factory. To use the external motor release, the bridge must be removed and replaced by the customer s external switching device (Refer to Wiring Diagram). Terminal strip XL2 (Contact 1 and 2 bridged by factory) Contacts 1 and 2 switched externally Contacts 1 and 3 switched externally The motor can be turned off externally. But to turn the motor back on, it must be turned on externally, then the button Motor Start must be pressed. The buttons Motor Start and Motor Stop no longer have a function 10. Connecting Inert gas See manual Inert Gas Equipment.

28 3-4 Installation 11. Installing Heated Hoses WARNING: Hot! Risk of burns. Wear heat protective gloves. Connecting If cold hot melt material can be found in the hose connection fitting (1) and/or hose connection (2), these components must be heated until the material softens (approx. 80 C, 176 F). 1. First connect the hose (3) electrically to the unit. For more than one hose: every hose connection fitting is allocated to a corresponding connection socket. Do not mistakenly exchange! NOTE: For units with recirculation hoses: do not mistake recirculation hoses for feed hoses. 2. Heat the unit and hose to approx. 80 C (176 F). Fig. 3-4 Principle drawing MXHH001S050A Screw the hose onto the unit. NOTE: Close unused hose connection fittings with Nordson screw caps. Disconnecting WARNING: System and hot melt material pressurized. Relieve pressure before disconnecting heated hoses. Failure to observe can result in serious burns. Relieving Pressure 1. Set motor speed to 0 RPM; switch off motor(s). 2. Place a reservoir under the nozzle(s) of the application head/hot melt handgun. 3. Activate the solenoid valve(s) electrically or manually; or, pull the trigger of the hot melt handgun. Repeat this procedure until no more hot melt material flows out. 4. Re-use the hot melt material or dispose of properly according to local regulations. Second Open jawed Wrench Using a second open jawed wrench prevents the hose connection fitting on the unit from turning. MXHH002S033A0295 Fig. 3-5 Principle drawing

29 Section 4 Operation

30 4-0 Operation

31 Operation 4-1 Section 4 Operation WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation. 1. Filling the Tank WARNING: Hot! Risk of burns. Wear safety goggles and heat protective gloves. Risk of burns from the tank lid when the tank hood has been opened. Hot adhesive can splash out of the tank when it is being filled. Insert the adhesive carefully. Before filling the tank, make sure the tank and hot melt material are clean and free of foreign substances. Foreign substances can damage the unit and accessories. Also ensure that the inert gas inlet hole and the tank deaeration hole are not plugged with adhesive. NOTE: Do not completely empty the tank. If there is too little adhesive in the tank, the adhesive can overheat. This can cause adhesive residue and hardening, resulting in malfunctioning. MCTK017S050A0397 Fig. 4-1 Maximum Filling Level Ensure that the melted adhesive can not reach the inert gas inlet hole and the tank deaeration hole.

32 4-2 Operation Opening and Closing Tank WARNING: Hot! Risk of burns on the tank lid after opening the tank hood. Wear heat protective gloves. WARNING: Do not operate the unit when the tank lid is open. Hot melt material vapors which may contain hazardous substances can escape. 1 WARNING: The tank lid may not be opened until the quick dearation procedure is audibly completed CAUTION: Do not operate unit when tank hood is open. When the hood is open the tank is relieved of inert gas pressure, and no inert gas pressurization occurs. This can result in the adhesive hardening in the tank. Opening Tank 1. Open the tank hood (1) (Also refer to Tank Hood Switch). 2. Open the tank lid lock (3). 3. Pull the tank lid open with the aid of the tank lid handle (2) until the tank lid detent (5) locks into place Closing Tank 1. Hold on to the tank lid with the aid of the tank lid handle (2). Pull the tank lid detent (5) back and close the tank lid. 2. Lock the tank lid lock (3). 3. Close the tank hood (1) (Also refer to the Tank Hood Switch). Tank Hood Switch The tank hood switch (4) activates the following functions on opening and closing the tank hood (1): 5 Tank hood is opened Tank is relieved of inert gas pressure (quick deaeration). Tank hood is closed Inert gas is applied to the tank for the period set on the timer relay. Inert gas supply carried out at regular intervals as set on the temperature controller. 6 MCSY335S220B0697 Timer relay Function Setting range Factory settings K6 Inert gas supply 0.5 to 10 minutes 30 seconds Fig. 4-2

33 Operation Operating Elements All of the operating elements are described in Section 2, Description. 3. Setting Temperatures Refer to manual Temperature Controllers. NOTE: Processing temperature is also referred to in the description of the Control System as nominal value temperature. NOTE: The temperature setting is determined by the processing temperature prescribed by the hot melt material supplier. Do not exceed the maximum operating temperature of the unit or heated system components. Nordson assumes no guarantee and/or liability for damage caused by incorrect temperature settings. NOTE: Depending on the adhesive used, the overtemperature thermostats of the tank and possibly of the optional can receptacle may need to be adapted to the maximum processing temperature of the adhesive (This may mean that the overtemperature thermostats have need to be replaced). The switchoff value of the thermostat may not exceed the max. operating temperature of the unit! For thermostats see section Specifications. General Values Heating zone / Temperature / Time The values in the table are general values for temperature settings. Setting Tank 10 C (50 F) below prescribed processing temperature Undertemperature value 10 C (50 F) below set processing temperature Overtemperature value 10 to 30 C (50 86 F) above set processing temperature Setback temperature Setback period As required As required Application head (Accessories) Prescribed processing temperature(s) Heated hose (Accessories) Prescribed processing temperature 4. Setting Inert Gas Control Refer to manual Temperature controllers.

34 4-4 Operation 5. Setting Adhesive Output Quantity The amount of adhesive necessary (application weight) depends on the customer s hot melt material deposit and must be determined through experimentation. Without Pressure Control Valve The adhesive output quantity or the torque is set with the torque controller (9, Fig 2 2) within a range of 0 to 100 %. The selected setting should be locked in to avoid accidental resetting. NOTE: Torque motors function in a special way. They do not run constantly at a set speed; instead their purpose is to supply torque at standstill or at any partial speed. In practice this means that the motor comes to a standstill when the nozzle of an adhesive application head is closed and begins operation again when the nozzle is opened. With Pressure Control Valve (Option) On units that are equipped with the optional safety valve used on this unit as a pressure control valve a more even adhesive output quantity can be set. The pressure control valve (20, Fig 2 1) is located between the tank and the gear pump. Setting range 0 to 7.0 MPa 0 to 70 bar 0 to 1015 psi Factory setting 3.5 MPa 35 bar 508 psi Turning to the right Turning to the left Increases adhesive pressure / output quantity Decreases adhesive pressure / output quantity 1. Set torque controller to the necessary value. 2. Set the pressure control valve such that the motor speed remains nearly stable when the application head nozzle is closed. 3. Alternately set the torque controller and the pressure control valve in order to set the adhesive output quantity as evenly as possible. 4. Lock torque controller.

35 Operation Initial Startup After the unit has been properly installed, initial startup can take place. NOTE: The unit was subjected to extensive functional tests prior to shipment. In doing so, the tank was filled with a special test material. Residues of this material may still be present in the unit. To remove these residues, melt and feed several kilograms of hot melt material before starting production. NOTE: The temperature setting is determined by the processing temperature prescribed by the hot melt material supplier. Do not exceed the maximum operating temperature of the unit or heated system components. Nordson assumes no guarantee and/or liability for damage caused by incorrect temperature settings. NOTE: Nordson gear pumps may not be operated without hot melt material. Before switching on the motor, make sure the tank is filled. NOTE: Before executing the following steps, the user must be familiar with the operation of the temperature controller. 1. Ensure that the tank is pressurized with inert gas. 2. Set main switch to position I/ON. 3. Activate button Heating on. 4. Fill the tank. 5. Close tank lid and tank hood. 6. Carry out all settings on the temperature controller. 7. Set timer relay (see under Opening and Closing Tank). 8. Wait until the unit is ready for operation (green lamp on temperature controller is lit). 9. Switch on the motor. 10. Set adhesive output quantity or torque.

36 4-6 Operation 7. Daily Switch ON/OFF Daily Switch ON/OFF has the same meaning as the terms starting and stopping. Daily Switch ON NOTE: Nordson gear pumps may not be operated without hot melt material. Before switching on the motor, make sure the tank is filled. 1. Ensure that the tank is pressurized with inert gas. 2. Set main switch to position I/ON. 3. Activate button Heating on. 4. Fill hot melt material if necessary. 5. Wait until the unit is ready for operation. 6. Switch on the motor. 7. Set adhesive output quantity or torque. Daily Switch OFF (Inert Gas also Off) 1. Switch off the motor. 2. Set main switch to position 0/OFF. 3. Secure main switch with padlocks if necessary to prevent unauthorized operation. CAUTION: When the main switch is set to 0/Off, the inert gas equipment is turned off and the tank is deaerated. This could cause hardening of the adhesive in the tank. Daily Switch OFF (Inert Gas not Off) 1. Switch off the motor. 2. Activate button Heating off. 8. Emergency Switch OFF WARNING: Switch off the unit immediately in any emergency situation. 1. Set main switch to 0/OFF. 2. After standstill and before switching the unit on again, have the malfunction eliminated by qualified personnel.

37 Operation Settings Record Form Make a copy of the form before filling it out. Production information: Hot melt material: Supplier Processing temperature Viscosity Cleaning agent: Supplier Flash point Leading channel: Tank (factory-set) Processing temperatures (nominal value temperatures): Tank Heated hose (Accessories) 1) 2) Application head (Accessories) 1) 2) Air heater (Accessories) 1) 2) Motor torque: Timer relay: Inert gas control: Feeding time Interval Air pressure at application head (Accessories): Control air 1) 2) Spray air 1) 2) Notes: Name Date

38 4-8 Operation

39 Section 5 Maintenance

40 5-0 Maintenance

41 Maintenance 5-1 Section 5 Maintenance WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation. NOTE: Maintenance is an important preventative measure for maintaining operational safety and extending the lifetime of the unit. It should not be neglected under any circumstances. 1. Relieving Pressure WARNING: System and hot melt material under pressure. Before removing heated hoses, application heads or hot melt handguns, relieve system pressure. Failure to observe can result in serious burns. WARNING: Hot! Risk of burns. Wear heat-protective gloves. 1. Set motor speed to 0 RPM; switch off motor(s). 2. Place a reservoir under the nozzle(s) of the application head/hot melt handgun. 3. Trigger the solenoid valve(s) electrically or manually; or, pull the trigger of the hot melt handgun. Repeat this procedure until no more hot melt material flows out. 4. Re use hot melt material or dispose of properly according to local regulations.

42 5-2 Maintenance 2. Daily Maintenance Some of the maintenance activities described under Regular Maintenance may have to be carried out daily. Unit part Activity Interval Refer to Entire unit External cleaning Daily Page 5-3 Inspection for external damage Daily Page 5-3 Tank Visual inspection for impurities in Before every tank filling the tank Visual inspection of holes for inert gas supply, air exhaust, etc. to check whether they are clogged with adhesive; clean if necessary 3. Regular Maintenance The stated intervals are general guidelines based on experience. Depending on the location of the unit, production conditions and operating time of the unit, other maintenance intervals may prove necessary. Unit part Activity Interval Refer to Electrical cabinet fan Check filter, clean or replace if Depending on dust Page 5-3 necessary accumulation; daily if necessary Power cable Inspection for damage Every time the unit is serviced Air hoses Inspection for damage Every time the unit is serviced Gear pump Refer to separate manual Motor / gear box Refer to separate manual Tank Refer to separate manual Safety valve Refer to separate manual (Pressure control valve) Inert gas equipment Refer to separate manual Air dryer with compressed air filter (Special equipment) Refer to separate manuals

43 Maintenance External Cleaning External cleaning prevents pollution created by production from causing unit malfunctions. CAUTION: Observe the unit s Degree of Protection when cleaning (see Specifications). CAUTION: Do not damage or remove warning signs. Damaged or removed warning signs must be replaced by new ones. Only remove hot melt material residues with a cleaning agent recommended by the hot melt material supplier. Pre heat with an air heater if necessary. Vacuum up dust, fluffs etc. or remove them with a soft cloth. 5. Inspection for External Damage WARNING: When damaged parts pose a risk to the operational safety of the unit and/or safety of personnel, switch off the unit and have the damaged parts replaced by qualified personnel. Use only original Nordson spare parts. 6. Electrical Cabinet Fan Maintenance The electrical cabinet fan is maintenance free. The filter may have to be cleaned or replaced depending on dust emission. A dirty filter can be recognized by its dark color. Clean the filter by tapping out the dirt.

44 5-4 Maintenance 7. Changing Hot Melt Material Type Remove the old material from the unit by operating until empty or draining from the unit. NOTE: Before changing the material type, determine whether the old and new hot melt materials can be mixed. If mixing is possible: Residues of the old material can be flushed out using the new material. If mixing is not possible: Thoroughly flush the unit with a cleaning agent recommended by the hot melt material supplier. NOTE: Ensure proper disposal of the old hot melt material according to local regulations. Flushing with a Cleaning Agent CAUTION: Only use a cleaning agent recommended by the hot melt material supplier. Observe the Material Safety Data Sheet of the cleaning agent. Residues of the cleaning agent can be flushed out of the unit by the new hot melt material before production begins. NOTE: Ensure proper disposal of the cleaning agent according to local regulations.

45 Maintenance Maintenance Record Form Copy the form before filling out. Gear pump Unit part Date / Name Date / Name Date / Name Motor / gear box Electrical cabinet fan Tank Safety valve (Pressure control valve) Inert gas equipment Air dryer (Special equipment)

46 5-6 Maintenance

47 Section 6 Troubleshooting

48 6-0 Troubleshooting

49 Troubleshooting 6-1 Section 6 Troubleshooting WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation. WARNING: Some troubleshooting activities may have to be carried out when the unit is energized. Observe all safety regulations concerning energized parts (active parts). Failure to observe can result in electric shock. 1. Temperature Controller The temperature controller offers the following troubleshooting aids which are described in the manual Temperature Controllers: Indication lamps Diagnosis program Automatic fault display LEDs on the modules and boards 2. Helpful Tips Before beginning with systematic troubleshooting activities, check the following points: Are all parameters correctly set? Do all plug connections have sufficient contact? Have fuses been activated? Are external, inductive loads (e.g. solenoid valves) equipped with freewheeling diodes? The freewheeling diodes must be directly allocated to the inductive load, e.g. through luminous sealings. 3. Safety Valve The safety valve mentioned in some of the charts is an option and is used in this unit as a pressure control valve.

50 6-2 Troubleshooting 4. Indication Lamps The indication lamps show the following operating modes: Red (15) = Collective fault indication. The red lamp indicates that the temperature controller has recognized a fault. See troubleshooting table Red indication lamp is lit. White (14) = Switched ON. After switching on and during the heating phase, at first only the white indication lamp is lit (normal condition). A fault has first occurred when the temperature does not increase (observe temperature display) and when the green indication lamp is not lit after the heating phase has ended (1 hour and longer). See troubleshooting table Only the white indication lamp is lit. Green (13) = Ready for operation. The green indication lamp lights when all channels have reached their nominal value temperatures C F XXCO082L065B0199 Fig. 6-1 (For position numbers see also manual Temperature Controller)

51 Troubleshooting Troubleshooting Tables The troubleshooting tables serve as an orientation for qualified personnel. They cannot, however, replace targeted troubleshooting with the help of wiring diagrams and measuring instruments. They also do not include all possible problems, only those which most typically occur. Only the White Indication Lamp is Lit Possible Cause Possible Fault / Troubleshooting Corrective Action Refer to Activate diagnosis program of the temperature controller Nominal value temperatures of one or more heating zones are not reached Fuse(s) defective (There are also fuses located on the modules and the boards) Turn on or replace Manual Temperature Controller Manual Temperature Controller Wiring diagram Broken or loose cable Replace or tighten Overtemperature thermostat (on the Replace Spare parts list tank) defective Temperature sensor(s) defective Replace Solid state relay defective Replace Heater(s) defective Replace (Heaters in tank and heated hose can not be replaced) Temperature setback is switched on Switch off or wait until the setback period has expired Manual Temperature Controller Red Indication Lamp is Lit Possible Cause Possible Fault / Troubleshooting Corrective Action Refer to Overtemperature message from temperature controller (Display 3: Hi blinking) Undertemperature emergency switchoff from temperature controller (Displays 1, 2 and 3: blinking) Undertemperature during operation (Display 3: Lo blinking) Ambient temperature too high (Displays 1, 2 and 3: AM bie nt blinking) Temperature sensor short circuit (Display 3: S blinking) Temperature sensor interruption (Display 3: E blinking) Manual Temperature Controller, Service message Error Adhesive was filled up Wait until temperature has been reached again Manual Temperature Controller, Service message Error Ambient temperature is too high Lower ambient temperature by aerating or cooling Electrical cabinet ventilation filter dirty Clean or replace Section 5 Electrical cabinet fan defective Replace Replace Replace

52 6-4 Troubleshooting Unit does not Function Possible Cause Possible Fault / Troubleshooting Corrective Action Refer to No line voltage Connect line voltage supply Section 3 Main switch not turned on Turn on main switch Section 2 Main switch defective Replace main switch Main fuse activated Turn on main fuse Main fuse activated again Check for short circuit in the unit or Wiring diagram accessories Fuse Control voltage (UN / UL) activated Check for short circuit in the unit or accessories Overtemperature thermostat triggered Temperature set too high Correct temperature setting and wait for unit to cool off Adhesive manufacturers data sheet Wrong overtemperature thermostat Replace Section 7 installed Temperature controller defective Replace One Channel (Heating Zone) does not Heat Possible Cause Possible Fault / Troubleshooting Corrective Action Refer to Channel is turned off Turn on Manual Channel switched to measuring mode Switch to control mode Temperature Controller Channel / heating zone defective Activate diagnosis program of the temperature section No Hot Melt Material (Motor does not Rotate) Possible Cause Possible Fault / Troubleshooting Corrective Action Refer to Wait until unit is heated up and green indication lamp is lit Unit not yet ready for operation (Undertemperature during heating phase) Unit not ready for operation (Undertemperature during operation) Adhesive was filled up Wait until unit is heated up and green indication lamp is lit Troubleshooting table Only the white indication lamp is lit Motor not turned on Turn on Manual Undertemperature during operation Temperature re Controller Speed not set Set speed Temperature setback turned on Turn off or wait until the setback time has expired Motor defective Replace Motor is not supplied with voltage Determine error through measuring Wiring diagram Fuses defective Replace Torque controller defective Replace

53 Troubleshooting 6-5 No Hot Melt Material (Motor Rotating) Possible Cause Possible Fault / Troubleshooting Corrective Action Refer to Tank empty Fill tank Section 3 Adhesive feed port to the pump or Unscrew pump and feed port or clean Manual Gear Pump suction hole to pump blocked suction hole Pump does not turn Coupling screws loose Tighten Not Enough Hot Melt Material Possible Cause Possible Fault / Troubleshooting Corrective Action Refer to Adhesive feed port to the pump or Unscrew pump and feed port or clean Manual Gear Pump suction hole to pump partially blocked suction hole Safety valve defective Clean or replace Manual Safety Valve Processing temperature set too low Correct temperature setting Adhesive manufacturers data sheet Pump block of gear pump worn Replace pump Manual Gear Pump Hot Melt Material Pressure Too High Possible Cause Possible Fault / Troubleshooting Corrective Action Refer to Safety valve dirty (and thus blocked) Disassemble and clean or replace Manual Safety Valve Safety valve defective Replace Hot Melt Material Pressure Too Low Possible Cause Possible Fault / Troubleshooting Corrective Action Refer to Safety valve dirty (and thus blocked) Disassemble and clean or replace Manual Safety Valve Safety valve defective Replace Hot Melt Material Residues in Tank Possible Cause Possible Fault / Troubleshooting Corrective Action Refer to Tank setpoint temperature too high Correct temperature setting Adhesive manufacturer data sheet

Hot Melt Material Applicator MC 12 / MC 24

Hot Melt Material Applicator MC 12 / MC 24 Hot Melt Material Applicator Manual P/N 403 076 D English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice

More information

Electropneumatic Hot Melt Application Heads EP 34 / EP 34 S / EP 34 SD

Electropneumatic Hot Melt Application Heads EP 34 / EP 34 S / EP 34 SD Electropneumatic Hot Melt Application Heads Manual P/N 409 090 A English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson

More information

Hot Melt Applicator MC 405 for Foil Bags

Hot Melt Applicator MC 405 for Foil Bags Hot Melt Applicator for Foil Bags Manual English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY NOTE This manual is for products with the following P/N: 8015767 8022490 8027924 8037680 8018042 8023117 8031127

More information

Drum Melters DG 21 / DG 201

Drum Melters DG 21 / DG 201 Drum Melters DG 21 / DG 201 Manual P/N 464 839 A - English - NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products

More information

Hot Melt Application Head Series PW...

Hot Melt Application Head Series PW... Hot Melt Application Head Series... Manual English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice This

More information

Bulk Melters BM 200 with Piston Pump for 200 l Drums

Bulk Melters BM 200 with Piston Pump for 200 l Drums Bulk Melters BM 200 with Piston Pump for 200 l Drums Manual P/N 464 937 B - English - NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number

More information

Bulk Melters BM 200 with Gear/Gerotor Pump for 200 l Drums

Bulk Melters BM 200 with Gear/Gerotor Pump for 200 l Drums Bulk Melters BM 200 with Gear/Gerotor Pump for 200 l Drums Manual P/N 464 958 C - English - NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order

More information

Sponge Cleaner. Manual P/N A English. Issued 05/03 NORDSON (UK) LTD STOCKPORT

Sponge Cleaner. Manual P/N A English. Issued 05/03 NORDSON (UK) LTD STOCKPORT Sponge Cleaner Manual P/N 768 651 A English Issued 05/03 NORDSON (UK) LTD STOCKPORT Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation publication which is protected

More information

U7698E Flame Detector

U7698E Flame Detector U7698E Flame Detector Customer Product Manual Issued 3/02 NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments, and inquiries about its products. General

More information

Fill Sentry. Automated Fill System. Customer Product Manual Part A. NORDSON CORPORATION

Fill Sentry. Automated Fill System. Customer Product Manual Part A. NORDSON CORPORATION Fill Sentry Automated Fill System Customer Product Manual Part NORDSON CORPORATION www.nordson.com CAUTION: If this equipment is used with other Nordson equipment, refer to the manuals provided with that

More information

Hot Melt Material Applicator MC 4420

Hot Melt Material Applicator MC 4420 Hot Melt Material Applicator Manual English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice This is

More information

Envirocoat Twin Cyclone Powder Coating Booth

Envirocoat Twin Cyclone Powder Coating Booth Envirocoat Twin Cyclone Powder Coating Booth Manual P/N 779166 --English-- Keep for Future Reference Nordson China Sourcing - Shanghai Trademarks AccuJet, Aquaguard, Asymtek, Automotive, Autotech, Blue

More information

Seal Sentry Series 10 Bead Detection System

Seal Sentry Series 10 Bead Detection System Seal Sentry Series 10 Bead Detection System Customer Product Manual P/N 321 289D02 This equipment is regulated by the European Union under WEEE Directive 2002/96/EC). See www.nordson.com for information

More information

Bulk Melters BM 200 with Piston Pump - EASY Pneumatics -

Bulk Melters BM 200 with Piston Pump - EASY Pneumatics - Bulk Melters BM 200 with Piston Pump - EASY Pneumatics - Manual - English - Issued 05/06 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note After approx. December 2003, this manual applies to the entire series.

More information

Level Monitor LA 100

Level Monitor LA 100 Level Monitor LA 100 Manual English NORDSON BENELUX MAASTRICHT THE NETHERLANDS www.nordson.com Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation publication which

More information

Powder Conditioning System

Powder Conditioning System Powder Conditioning System Manual P/N 779168 --English-- Keep for Future Reference Nordson China Sourcing - Shanghai Table I Trademarks AccuJet, Aquaguard, Asymtek, Automotive, Autotech, Blue Box, CF,

More information

Fluidking. Manual P/N A English NORDSON (UK) LIMITED STOCKPORT UK

Fluidking. Manual P/N A English NORDSON (UK) LIMITED STOCKPORT UK Manual P/N 768 643 A English NORDSON (UK) LIMITED STOCKPORT UK Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation publication which is protected by copyright. Original

More information

Fixed Reclaim System

Fixed Reclaim System Fixed Reclaim System Manual P/N 779163 --English-- Keep for Future Reference Nordson China Sourcing - Shanghai Trademarks AccuJet, Aquaguard, Asymtek, Automotive, Autotech, Blue Box, CF, Can Works, Century,

More information

LA 820 / LA 820 RC Liquid Adhesive Gun

LA 820 / LA 820 RC Liquid Adhesive Gun Liquid Adhesive Gun Manual English NORDSON BENELUX MAASTRICHT THE NETHERLANDS Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation publication which is protected by

More information

DuraDrum Bulk Melters DD200

DuraDrum Bulk Melters DD200 DuraDrum Bulk Melters Manual English Issued 11/07 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice This

More information

Hot Melt Applicators SB60 BoD

Hot Melt Applicators SB60 BoD Hot Melt Applicators Manual - English - Edition 06/14 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This document applies to the entire series. Order number P/N = Order number for Nordson articles Note

More information

Hot Melt Material Applicator MC 7

Hot Melt Material Applicator MC 7 Hot Melt Material Applicator MC 7 Parts List P/N 735003A English Issued 2/06 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation

More information

Hot-melt adhesive extruder EEX40

Hot-melt adhesive extruder EEX40 Hot-melt adhesive extruder EEX40 Manual 110900563/001 - English - Nordson Deutschland GmbH Buchholz-Mendt GERMANY Note This manual applies to the entire series. Part number P/N = 7549584 Notice This is

More information

Series AD-31 and Series L4 Extrusion Handguns

Series AD-31 and Series L4 Extrusion Handguns Series AD-31 and Series L4 Extrusion Handguns Customer Product Manual Issued 5/05 NORDSON CORPORATION DULUTH, GEORGIA USA www.nordson.com For CE Declaration, refer to melter documentation. Nordson Corporation

More information

Liquid Adhesive Detection System Alarm Box

Liquid Adhesive Detection System Alarm Box Liquid Adhesive Detection System Alarm Box Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products.

More information

Replacing a Gun Thermostat

Replacing a Gun Thermostat Instruction Sheet Replacing a Gun Thermostat WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation.

More information

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN. INSTALLATION, OPERATION & SERVICE MANUAL FOR COOLER TYPES OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN. 1. Introduction This manual is a guide for the installation, maintenance

More information

FillEasy C Adhesive Feed System

FillEasy C Adhesive Feed System FillEasy C Adhesive Feed System Customer Product Manual Issued 5/10 This document contains important safety information Be sure to read and follow all safety information in this document and any other

More information

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A... 70 80 99-00-O Residential Gas Condensing Boiler ZBR//8/35/4-3A... ZWB8/35/4-3A... 70 80 993 (03/03) CA/US Operating Instructions Contents Contents Key to symbols and safety instructions............................

More information

GD-500 Bead Detection System

GD-500 Bead Detection System GD-500 Bead Detection System Customer Product Manual Issued 4/08 NORDSON CORPORATION DULUTH, GEORGIA USA www.nordson.com Nordson Corporation welcomes requests for information, comments, and inquiries about

More information

Automatic Hot Melt Melter/Feeder Retrofit Kit Mechanical Float Model. Part104506A

Automatic Hot Melt Melter/Feeder Retrofit Kit Mechanical Float Model. Part104506A Automatic Hot Melt Melter/Feeder Retrofit Kit Mechanical Float Model Part456A NORDSON CORPORATION. AMHERST, OHIO USA Corporation welcomes requests for information, comments and inquiries about its products.

More information

CleanSpray System Operation

CleanSpray System Operation Nordson Corporation OPERATOR S CARD P/N 108684C CleanSpray System Operation Introduction The individual manuals for the CleanSpray Gun, CleanSpray Controller and Model 25B Pump are included with each component.

More information

AltaSpray Plus Applicators

AltaSpray Plus Applicators AltaSpray Plus Applicators Customer Product Manual Issued 5/3 This document contains important safety information Be sure to read and follow all safety information in this document and any other related

More information

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN TTV 1500 / TTV 3000 EN OPERATING MANUAL CONVEYING FAN TRT-BA-TTV1500-3000-TC2016-26-004-EN Table of contents Notes regarding the operating manual... 2 You can download the current version of the operating

More information

Bulk Melters AltaPail

Bulk Melters AltaPail Bulk Melters AltaPail Manual - English - Edition 02/12 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This document is for products with the following P/N: 7165698 7157455 7157502 7157503 Order number

More information

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Original Installation Instructions 810437-08 Contents Foreword... 3 Availability... 3 Formatting features in the document... 3 Safety... 3 Use for the intended purpose...

More information

FC-2200 Flame Detector

FC-2200 Flame Detector FC-2200 Flame Detector Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence

More information

Operating Instruction

Operating Instruction Version 0 21/02/2017 Operating Instruction Hot air dryer english Item No. 108 3106 Elma Schmidbauer GmbH Gottlieb-Daimler-Str. 17 D-78224 Singen Tel. +49 7731 882-0 Fax +49 7731 882-266 info@elma-ultrasonic.com

More information

Operating manual. a Look Solutions 1 product

Operating manual. a Look Solutions 1 product Operating manual a Look Solutions 1 product Set of Equipment supplied 1 Unique 2 1 tank lid with quick connector, silicon tube and air valve filter 1 canister of UNIQUE-fluid, 2l 1 manual As an option:

More information

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A... Residential Gas Condensing Boiler Greenstar combi 00 p / 5 p ZWB8-3A... ZWB4-3A... Operating Instructions 708733 (07/04) US/CA Contents Contents Explanation of symbols and safety instructions.......................

More information

Propane Flame Projector Safety instructions and operating manual

Propane Flame Projector Safety instructions and operating manual Bigflame Propane Flame Projector Safety instructions and operating manual 1 Flame projector Bigflame Safety instructions Caution The directions in this manual must be followed strictly. It is imperative

More information

Refrigerant Recovery Machine. Model No Operating Manual

Refrigerant Recovery Machine. Model No Operating Manual Refrigerant Recovery Machine Model No. 25700 Operating Manual Safety Precautions WARNING : TO PREVENT PERSONAL INJURY AND / OR EQUIPMENT DAMAGE, CAUTION - Risk of injury. This equipment should only be

More information

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN AIRGOCLEAN 10 E EN OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN Table of contents Notes regarding the operating manual... 1 You can download the current version of the operating manual and

More information

ULTRA LOW TEMPERATURE FREEZER. User Manual

ULTRA LOW TEMPERATURE FREEZER. User Manual ULTRA LOW TEMPERATURE FREEZER User Manual Note:Kaltis reserves the right to modify any parts of this manual without prior notice. 1. No part of this manual may be reproduced in any form, or translated

More information

POLYMIX PX-IG 2000 Operating Instructions

POLYMIX PX-IG 2000 Operating Instructions POLYMIX PX-IG 2000 Operating Instructions Voltage D 100-120V, 50/60 Hz D 210-250V, 50/60 Hz Please check that the voltage is correct and corresponds with the nameplate on the back of the machine. Manual

More information

Product Manual Glue Applicators MS 80 and MS 200

Product Manual Glue Applicators MS 80 and MS 200 Product Manual www.pakarte.com Glue Applicators MS 80 and MS 00 Translation from German to English Table of Contents Product Description General Safety Instructions Safety Measures to be taken during Operation

More information

Non-RTD Hot Melt Hose Replacement

Non-RTD Hot Melt Hose Replacement Instruction Sheet P/N 7C 0 Safety WARNING: System pressurized! Relieve system hydraulic pressure before breaking any hydraulic connection or seal. Failure to relieve the system hydraulic pressure can result

More information

SILENT V4 TRANSLATION OF THE ORIGINAL INSTRUCTIONS FOR USE. Made in Germany

SILENT V4 TRANSLATION OF THE ORIGINAL INSTRUCTIONS FOR USE. Made in Germany SILT V4 TRANSLATI OF THE ORIGINAL INSTRUCTIS FOR USE Made in Germany 21-6669 26092016 1. Introduction... 2 1.1 Symbols... 2 2. Safety... 3 2.1 Intended Use... 3 2.2 Improper Use... 3 2.3 Ambient Conditions

More information

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO: WARNING Read the instructions before using the machine PRESSURE WASHER MODEL NO: JETSTAR 1750 PART NO: 7333230 OPERATION & MAINTENANCE INSTRUCTIONS LS0711 INTRODUCTION Thank you for purchasing this CLARKE

More information

Hot-melt adhesive extruder EEX100

Hot-melt adhesive extruder EEX100 Hot-melt adhesive extruder EEX100 Manual 111121287/001 -- English -- NordsonDeutschlandGmbHBuchholz--MendtGERMANY Note This manual applies to the entire series. Part number P/N = 7552471 Notice This is

More information

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A Millo / Millo pro Nr. 1804-x000 / 1805-x000 0609 21-6543 A Ideen für die Dentaltechnik 1 2 3 4 5 6 7 8 9 10 11 12 Millo / Millo pro No. 1804-x000 / 1805-x000 ENGLISH Content Introduction... 15 Symbols...

More information

PRO 2000i LOW LEVEL DEPOSITOR

PRO 2000i LOW LEVEL DEPOSITOR DEPOSITORS AND AUTOMATED CAKE PRODUCTION SYSTEMS PRO 2000i LOW LEVEL DEPOSITOR OPERATION AND SPARE PARTS MANUAL Serial No. PR2L- (Please quote this number when ordering spares, and making service calls)

More information

Original operating instructions Safety switch with guard locking AC901S AC902S

Original operating instructions Safety switch with guard locking AC901S AC902S Original operating instructions Safety switch with guard locking AC901S AC902S 7390914/03 01/2017 Contents 1 Preliminary note...4 1.1 Explanation of symbols...4 2 Safety instructions...4 3 Items supplied...5

More information

TECHNOSKLO Ltd. Držkov

TECHNOSKLO Ltd. Držkov TECHNOSKLO Ltd. Držkov Distillation apparatus for producing of distilled water TYPE DP 4000 Operating manual TECHNOSKLO Ltd. 468 24 Držkov 135 Czech Republic tel.: 00420 483 346 403 fax: 00420 483 385

More information

Instruction Manual Suppository Penetration Tester. Type PM 30

Instruction Manual Suppository Penetration Tester. Type PM 30 Instruction Manual Suppository Penetration Tester Type PM 30 ERWEKA GmbH * Ottostr. 20 22 * 63150 Heusenstamm * Germany * Tel: +49 (0) 6104 6903-0 Fax: +49 (0) 6104 6903-40 * E-mail: info@erweka.com *

More information

Silent V4 Nr

Silent V4 Nr Silent V4 Nr. 2933 0000 DE FR IT ES 21-6669 12052014 / A Made in Germany Ideas for dental technology Silent V4 Nr. 2933 0000 GLISH 1. Introduction... 2 1.1 Symbols... 2 2. Safety... 3 2.1 Intended Use...

More information

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them. K 1.100 Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them. www.kaercher.com/register-and-win 59651430 (10/13) Contents General information..............

More information

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS CONTENTS 1. INTRODUCTION... 5 2. WARNINGS... 6 3. GENERAL DESCRIPTION... 7 4. INSTALLATION... 8 5. LUMINOUS INDICATORS AND COMMANDS... 9 6. DIP-SWITCH

More information

Test Unit GTL 100 for Fire Detectors

Test Unit GTL 100 for Fire Detectors Test Unit GTL 100 for Fire Detectors Description and Operation Manual Zertifiziertes QM System Nach DIN EN ISO 9001 Description and Operation Manual Table of Contents 1. Instructions 1.1 General 1.2 Standards

More information

AD XT. Air Dryer Service Manual. Innovation with Integrity. Version 003 NMR

AD XT. Air Dryer Service Manual. Innovation with Integrity. Version 003 NMR AD XT Air Dryer Service Manual Version 003 Innovation with Integrity NMR Copyright by Bruker Corporation All rights reserved. No part of this publication may be reproduced, stored in a retrieval system,

More information

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL DATE OF PURCHASE: MODEL: SERIAL NO.: Record above information from nameplate. Retain this information for future reference.

More information

AD SP. Air Dryer Maintenance Manual. Innovation with Integrity. Version 001 NMR

AD SP. Air Dryer Maintenance Manual. Innovation with Integrity. Version 001 NMR AD SP Air Dryer Maintenance Manual Version 001 Innovation with Integrity NMR Copyright by Bruker Corporation All rights reserved. No part of this publication may be reproduced, stored in a retrieval system,

More information

HD 525 S 06/03 A ! 5.960

HD 525 S 06/03 A ! 5.960 HD 525 S 5 960 845 A2005225 06/03! Please read these operating instructions before starting and strictly observe the Safety Instructions for High Pressure Cleaners (5.951-949). WARNING DO NOT SPRAY ELECTRICAL

More information

Instruction Manual. Automatic fuel oil de-aerator SMART-FLO 3/K B100 COMPATIBLE

Instruction Manual. Automatic fuel oil de-aerator SMART-FLO 3/K B100 COMPATIBLE Sid Harvey s 605 Locust Street Garden City, NY 11530 Instruction Manual Automatic fuel oil de-aerator SMART-FLO 3/K Read manual before use! Observe all safety information! Keep manual for future use! 05.2015

More information

Tornado Operations & Maintenance Manual

Tornado Operations & Maintenance Manual TORNADO INDUSTRIES 7401 W. LAWRENCE AVENUE CHICAGO, IL 60706 (708) 867-5100 FAX (708) 867-6968 www.tornadovac.com Tornado Operations & Maintenance Manual MODEL NO. 99690 BD 22/14, 99720 BD 26/14 L9722

More information

USER MANUAL. Version: 1.0. ROBE Show Lighting s.r.o. Czech Republic

USER MANUAL. Version: 1.0. ROBE Show Lighting s.r.o. Czech Republic USER MANUAL Version: 1.0 ROBE Show Lighting s.r.o. Czech Republic www.robe.cz Table of contents 1.Introduction 4 2.Cautions 4 3. Unpacking & Inspection 5 4. Setup 5 5. Operation 5 5.1.Control Module Operation

More information

Operating Instructions

Operating Instructions Operating Instructions BA-003 Read and understand this manual before use. Keep this manual for future reference. CONFORMS TO UL STD.No.1017 Certified to CSA STD C22.2 No.243-10 For questions or concerns

More information

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro 2006/01 Content Important Information 1. Notes... 3 1.1 CE - Labeling... 3 1.2

More information

Instructions manual DEHUMID HP50

Instructions manual DEHUMID HP50 Instructions manual DEHUMID HP50 Table of contents 1. Unpacking 3 2. Intended use 3 3. Disposal 3 4. Safety instructions 3 5. Functional principle 4 6. Automatic defrosting system 4 7. Set up and transportation

More information

Installation Manual CARBONATOR With Plain-Water Booster

Installation Manual CARBONATOR With Plain-Water Booster CORNELIUS INC One Cornelius Place Anoka, MN 55303-6234 Telephone (800) 238-3600 Facsimile (763) 422-3246 Installation Manual CARBONATOR With Plain-Water Booster IMPORTANT: It is the responsibility of the

More information

PDA20DX Air Purifying Dehumdifier Manual

PDA20DX Air Purifying Dehumdifier Manual PDA20DX Air Purifying Dehumdifier Manual Index Important Safe Guards Ambient Environment For Operating Components Diagrams---Parts Names Operating Introduction---How to operate - Functions of Control Panel

More information

Operational Instructions. Glue Applicator MS Translation from German to English

Operational Instructions. Glue Applicator MS Translation from German to English Operational Instructions Glue Applicator MS 200 Translation from German to English Table of Contents Product Description 1 General Safety Instructions 2 Safety Measures to be taken during Operation 3 Start-up

More information

WARNING: Warns of health hazards and identifies possible risks of injury. CAUTION: Indicates possible dangers to the machine or other objects.

WARNING: Warns of health hazards and identifies possible risks of injury. CAUTION: Indicates possible dangers to the machine or other objects. VBT3ASV USER GUIDE SAFETY INFORMATION About this user guide Read this user guide completely before using the machine. Keep this user guide for reference. If you pass your machine on to third parties, it

More information

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL OPERATING AND INSTALLATION MANUAL TANKLESS ELECTRIC WATER HEATER WITH ELECTRO-MECHANICAL FLOW SWITCH» MINI 2» MINI 2.5» MINI 3» MINI 3.5» MINI 4» MINI 6 The Mini series is tested and certified by WQA against

More information

Oxiperm C 164 Fully automatic chlorine dioxide processing plant C, -6000C, -7500C, C. Service manual. Oxiperm 164C 4-10 kg Service en

Oxiperm C 164 Fully automatic chlorine dioxide processing plant C, -6000C, -7500C, C. Service manual. Oxiperm 164C 4-10 kg Service en Oxiperm 164C 4-10 kg Service en Oxiperm C 164 Fully automatic chlorine dioxide processing plant 164-4000C, -6000C, -7500C, -10000C Service manual 15.710138-V2.0 1 Imprint Oxiperm C 164 Fully automatic

More information

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S EN OPERATING MANUAL INFRARED HEATING PANEL TRT-BA-TIH300S-TIH400S-TIH500S-TIH700S-TIH900S-TIH1100S-TC-002-EN Table of contents Notes

More information

Reacti-Therm I and III Heating Modules

Reacti-Therm I and III Heating Modules INSTRUCTIONS Reacti-Therm I and III Heating Modules TS-18822 TS-18824 Number TS-18822 TS-18824 Description Reacti-Therm I Heating Module (single block) Reacti-Therm III Heating Module (triple block) 2101.1

More information

PJ130S High Pressure Cleaner

PJ130S High Pressure Cleaner PJ130S High Pressure Cleaner Operator Manual Original instructions WARNING: Do not use the machine without reading the instruction sheet. Item Description OVERVIEW 1. High pressure washer 2. On/off switch

More information

/2010 US/CA

/2010 US/CA 6 720 646 148-11/2010 US/CA (en) For the user User s Instructions Condensing gas boiler Logamax plus GB162-L.B. 80 kw/100 kw Please read thoroughly before operating This manual is available in the English

More information

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit Owner s Manual Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit Model AC375C Recover, Recycle, and Recharge Unit for R-12 or R-134a Refrigerant Voltage: 220 230; 50 60 Hz SAFETY DEFINITIONS:

More information

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN TTK 75 ECO EN OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN Table of contents Notes regarding the operating manual... 01 Information about the device... 02 Safety... 04 Transport...05 Start-up...05

More information

Operations and Safety Manual

Operations and Safety Manual Tuffy Jr. Heated Soil Extractor Operations and Safety Manual BEFORE YOU START: SAFETY OPERATION SERVICE PARTS TROUBLESHOOTING RETURN GOODS POLICY! READ and UNDERSTAND this material before operating or

More information

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL OPERATING AND INSTALLATION MANUAL TANKLESS ELECTRIC WATER HEATER WITH ELECTRO-MECHANICAL FLOW SWITCH» MINI 2» MINI 2.5» MINI 3» MINI 3.5» MINI 4» MINI 6 The Mini series is tested and certified by WQA against

More information

High-Pressure Washer BY02-VBP-WTR BY02-VBP-WTH. CAUTION : Do not use this device before reading the instructions.

High-Pressure Washer BY02-VBP-WTR BY02-VBP-WTH. CAUTION : Do not use this device before reading the instructions. High-Pressure Washer BY02-VBP-WTH BY02-VBP-WTR CAUTION : Do not use this device before reading the instructions. 1 1. Safety Instructions The appliance has been designed solely for private use outdoors

More information

Operating instructions

Operating instructions Operating instructions for Winterhalter Gastronom dishwasher GS 502 and GS 515 Contents Page 1 Intended use... 1 2 Installation and commissioning... 1 3 Safety instructions... 2 4 Operating panel... 3

More information

PWASH Gallon Parts Washer Assembly & Operating Instructions

PWASH Gallon Parts Washer Assembly & Operating Instructions PWASH20 20 Gallon Parts Washer Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. This manual provides important

More information

Operator s manual. Battery charger C 48/ en / 03

Operator s manual. Battery charger C 48/ en / 03 Operator s manual Battery charger C 48/13 03.2015 5100010183en / 03 Manufacturer Wacker Neuson Produktion GmbH & Co. KG Preussenstrasse 41 80809 Munich www.wackerneuson.com Tel.: +49-(0)89-354 02-0 Fax:

More information

OPERATION AND MONTAGE MANUAL ROOF FANS

OPERATION AND MONTAGE MANUAL ROOF FANS NO RF/U/2017 (ENGLISH) (valid since 13.10.2017) ROOF FANS RF / RFV Venture Industries Sp. z o.o. is not responsible for any damage caused by improper use of the fan and reserves the right to modify this

More information

HI COD REACTOR and Test Tube Heater 2008 Series

HI COD REACTOR and Test Tube Heater 2008 Series Instruction Manual HI 839800 COD REACTOR and Test Tube Heater 2008 Series www.hannainst.com This Instrument is in Compliance with the CE Directives 1 Dear Customer, Thank you for choosing a Hanna product.

More information

Bench-Top Vacuum Oven with 28 segments programmable controller

Bench-Top Vacuum Oven with 28 segments programmable controller Bench-Top Vacuum Oven with 28 segments programmable controller DZF-6000F Series Vacuum Oven MTI Corporation www.mtixtl.com 1 Safety notes DZF Vacuum Oven Please read the following safety notes carefully

More information

Hand Dryer Installation & User Manual

Hand Dryer Installation & User Manual Hand Dryer Installation & User Manual Please read instructions in conjunction with the illustrations Please save these instructions. Safety & Guidance notes Important:- Read all these instructions before

More information

MR3CCUHV Temperature/Defrost Control

MR3CCUHV Temperature/Defrost Control Master Catalog 125 Temperature Controls Section A Product/Technical Bulletin Issue Date 0401 MR3CCUHV Temperature/Defrost Control The MR3CCUHV Temperature/Defrost Control is designed to control the temperature

More information

Service package PDAD- -SP (en) Assembly instructions d [ ]

Service package PDAD- -SP (en) Assembly instructions d [ ] Service package PDAD- -SP-12000 (en) Assembly instructions 8068819 1701d [8068821] Original instructions Installation and commissioning are to be carried out only by qualified personnel in accordance with

More information

Owner s Manual RD432-0 Chemical Controller

Owner s Manual RD432-0 Chemical Controller Owner s Manual RD432-0 Chemical Controller Table of Contents I. Introduction page 2 A. Water Chemistry page 2 B. Safety page 3 C. System Components page 4 D. Specifications page 7 E. Controller Panel Descriptions

More information

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY π H-6621 INDUSTRIAL DEHUMIDIFIER 1-800-295-5510 uline.com WARNINGS Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord if possible. Failure

More information

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use! Mess-, Regel- und Überwachungsgeräte für Haustechnik, Industrie und Umweltschutz Lindenstraße 20 74363 Güglingen Telefon +49 7135-102-0 Service +49 7135-102-211 Telefax +49 7135-102-147 info@afriso.de

More information

INSTRUCTION MANUAL. Stirring hotplate (with probe and stand) Brand : (Dragon laboratory)

INSTRUCTION MANUAL. Stirring hotplate (with probe and stand) Brand : (Dragon laboratory) INSTRUCTION MANUAL Stirring hotplate (with probe and stand) Model : Brand : MS-H280-pro (Dragon laboratory) User Manual MS-H280-Pro MS-PA BlueSpin LED Digital Hotplate Magnetic Stirrer BlueSpin LED Digital

More information

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil 60. Item no: Z-3285

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil 60. Item no: Z-3285 Operating manual BlueMobil 60 Item no: Z-3285 Original operating manual Illustration shows item no Z-3285 Important Copyright It is essential that you read this manual thoroughly before the initial operation

More information

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge ENSPECO Recovery/ Recycle/ Evacuate/ Recharge RMS 3012 RMS 3034 Approved by UL/SAE to J-1991 R12 Purity Standards Approved by UL/SAE to J-2210 R134 Purity Standards This semi-automatic machine will recover

More information

OPERATION AND MONTAGE MANUAL ROOF FANS

OPERATION AND MONTAGE MANUAL ROOF FANS NO RFEC/U/2017-1 (EN) (valid since 18.08.2017) ROOF FANS RF/EC...-... / RFV/EC...-... Venture Industries Sp. z o.o. is not responsible for any damage caused by improper use of the fan and reserves the

More information