1 EN Trimbox Mixed Flow Fans TP220T TP221T TP222T TP223T Product Manual ventilation systems

2 Safety Information Important Information Important: read these instructions fully before the installation of this appliance 1. Installation of the appliance and accessories must be carried out by a qualified and suitable competent person and be carried out in clean, dry conditions where dust and humidity are at minimal levels. 2. This manual covers the installation of the Titon In-Line Fans 3. All wiring must conform to current I.E.E. Wiring Regulations and all applicable standards and Building Regulations. 4. The units must be connected to a local three pole isolation switch with a contact separation of at least 3mm. 5. The units are suitable for 230V ~ 50/60Hz single phase suppy. 6. The units are DOUBLE INSULATED and marked with symbol. There are no Earth terminals and these units MUST NOT BE EARTHED. 7. Ensure cable clamp is used and fully tightened. 8. Cable entry must be made using the grommet supplied. 9. The unit must be stored in a clean and dry environment. 10. Do not install the appliance in areas where the following may be present or occur; Excessive oil or a grease laden atmosphere, Corrosive or flammable gases, liquids or vapours, Ambient temperatures above 50 C or below 0 C, Obstructions which would hinder access to the fan unit. Ducting bends or duct transformations close to the fan unit. Humidity levels above 90% or is a wet environment. 2

3 11. The appliance is not suitable for installation to the exterior of the dwelling. 12. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children should be supervised to ensure that they do not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. 13. The unit must not be connected to a tumble dryer or a cooker hood. 14. Precautions must be taken to avoid the back-flow of gases into the room from an open flue appliance. 15. Ensure impellor rotates and is free from obsructions and debris before conneting ducting. 16. Ensure all ducting associated pipe work is free from debris and blockages before switching on the unit. Important environment information about this product. This symbol on this unit or package, indicates that disposal of this unit after its life cycle could harm the environment. Do not dispose the unit as municipal waste; it should be disposed by a specialized company for recycling. This unit should be returned to your distributor or to a local recycling service. Respect the local environmental rules. If in doubt contact your local authorities about waste disposal rules. 3

4 Explanation of symbols on the appliance. Read instruction Manual. Risk of Electric Shock. Isolate from the mains power supply before removing the cover. + Contains rotating mechanical parts. Following isolation from the mains power supply allow sufficient time for all moving parts to stop before removing any ducting. Airflow Direction 4

5 Contents Safety Information Important Information 2 Explanation of symbols on the appliance. 4 Product Information Product Features 6 Packaging Contents 6 Dimensions 7 Component Identification 8 Fixing 8 Ducting 9 Wiring 10 Commissioning 11 Overrun Timer 11 Speed Setup 12 Product Fiche 13 Maintenance Routine Maintenance 15 Cleaning 15 Faults 15 When this document is viewed as a PDF the headings & sub headings on this page are hyper links to the content. 5

6 Product Information Titon In-Line Fans are designed to extract humid & stale air and expel it to the exterior. They are also suitable for extracting air from one room and expelling it to another room. The fan unit is usually fitted in the ceiling void, well away from the inlet. This In-Line feature allows the inlet grille to be mounted in wet areas (eg near the splash zones of bathrooms) or even above a shower. As the unit is in the ceiling cavity (away from the inlet grille), noise from the fan is minimized Product Features Three speed Low, Medium & High. Overun timer, 3-30 minutes. Part Number TP220T TP221T TP222T TP223T Duct Diameter ID Ø100mm Ø125mm Ø150mm Ø160mm Supply Voltage V~ 50Hz Power Rating 30W 60W Supply Voltage V~ 60Hz Power Rating 38W 84W Fuse Rating 3A Protection Class Class II IP Rating IP55 Weight 1.9Kg 2.0Kg 3.0Kg 3.1Kg Packaging Contents Inspect the unit when taking delivery. Check the unit for damage and that all accessories have been supplied. Package supplied with; In-Line Fan Unit x 1. Product Manual x 1. Any shortages or damage must be immediately reported to the supplier. 6

7 Dimensions The diagram details the overall size of the unit. Installer must allow additional space around the unit to allow for future servicing and maintenance. Part Number TP220T TP221T TP222T TP223T Duct Diameter ID Ø100mm Ø125mm Ø150mm Ø160mm Dimensions mm ØA ØB C D E F G Fixing Centres H Fixing Centres

8 Component Identification Terminal Box Gromet INLET Fixing Holes Impellor Fixing The units are designed as in-line duct fans to be fitted between two duct runs. 1. Choose a suitable mounting location for the inlet grille. Ensure there is adequate clearance for the ducting. 2. Choose a suitable location for the extract grille ensuring there is adequate clearance for the ducting. 3. Choose a suitable mounting location for the fan unit. Ensure that a power outlet is installed near the intended location of the unit. 4. The fan unit must be positioned at the highest point on the system so the ducting will slope downwards to both grilles. 5. The airlfow direction is marked on the rating label. 6. Do not cover the fan unit with thermal insulation. Keep at least 100mm clearance between the unit and any thermal insulation. 7. Mount the unit to a support using suitable fixings through the four fixing holes. 8

9 8. The unit should be positioned so that the power cord is pointing downwards. 9. Orientation of the junction box can be adjusted to suit the fan units location 10. Unscrew and open the clamps. 11. Rotate the motor unit to the desired position. 12. Replace the clamps and tighten the screws. 13. The duct must not be installed vertically into a roof terminal - the product is not designed or intended for this type of installation. Ducting 1. Titon recommend using rigid ducting, any flexible ducting used should be fully extended. 2. All ducting joints must be fixed using a method that ensures a long term seal is achieved. 9

10 Wiring 1. Access to the wiring terminals is via the terminal box on top of the unit V~ TP 2xxT 50/60Hz N Ls L N L 10

11 Commissioning Overrun Timer The Overrun Timer is factory set to approximately 3 minutes. The Overrun Timer can be set between 3 and 30 minutes. Access to Overtime Timer Control is via the terminal box on top of the unit. WARNING: Unit uses a V~ supply and contains rotating mechanical parts. ISOLATE the unit from mains power supply and allow sufficient time for all moving parts to stop before Commissioning. Adjust the Overrun Timer Control on the PCB with using a small flat bladed screwdriver. Clockwise Increase. Counter clockwise Decrease.. 11

12 Speed Setup Access to Speed Selection is via the terminal box on top of the unit. WARNING: Unit uses a V~ supply and contains rotating mechanical parts. ISOLATE the unit from mains power supply and allow sufficient time for all moving parts to stop before Commissioning. The Titon Mixed Flow Fans runs at one of 3 speeds; 1. Low [L]; 2. Medium [M]; 3. High [H]. The factory default is Medium. To change the speed of the fan; disconnect the wire and reconnect to the terminal corresponding to the desired speed. 12

13 Documentation Product Fiche Supplier Name Supplier Address Titon 894 The Crescent Colchester Business Park Colchester Essex CO4 9YQ Model Ø100mm Trimbox Ø125mm Trimbox Mixed Flow In-line fan Mixed Flow In-line fan Model Identifier TP220T TP221T Declared Typology NRVU - UVU NRVU - UVU Type of Drive installed Multi-speed drive Multi-speed drive Type of heat recovery system none none Thermal efficiency of heat recovery not applicable not applicable Nominal NRVU Flow Rate (m3/s) Effective power input (kw) SFPint W/(m3/s) n/a n/a Face velocity in m/s n/a n/a Nominal external pressure in Pa Internal pressure drop in Pa n/a n/a Static efficiency of fan in accordance with (EU) No 327/ % - < 125W motor 22% - < 125W motor Declared maximum internal leakage rate (%) n/a n/a Energy performance of the filters n/a n/a Filter Warning (RVU) n/a n/a 13

14 Model Ø150mm Trimbox Ø160mm Trimbox Mixed Flow In-line fan Mixed Flow In-line fan Model Identifier TP222T TP223T Declared Typology NRVU - UVU NRVU - UVU Type of Drive installed Multi-speed drive Multi-speed drive Type of heat recovery system none none Thermal efficiency of heat recovery not applicable not applicable Nominal NRVU Flow Rate (m3/s) Effective power input (kw) SFPint W/(m3/s) n/a n/a Face velocity in m/s n/a n/a Nominal external pressure in Pa Internal pressure drop in Pa n/a n/a Static efficiency of fan in accordance with (EU) No 327/ % - < 125W motor 33% - < 125W motor Declared maximum internal leakage rate (%) n/a n/a Energy performance of the filters n/a n/a Filter Warning (RVU) n/a n/a Internet address (for dissassembly instructions) 14

15 Maintenance Routine Maintenance WARNING: The unit uses a V~ supply and contains rotating mechanical parts. ISOLATE the unit from mains power supply and allow sufficient time for all moving parts to stop before undergoing any Servicing or Maintenance. All ventilation units require periodic maintenance, units should be inspected and cleaned. Routine maintenance must only be carried out by a suitably qualified and competent person. Cleaning This product should only be cleaned with a damp cloth. Cleaning agents and solvents should not be used. In the event of any queries please contact the system installer. Faults This product contains no serviceable parts and no attempt should be made to repair it. If the product is faulty it should be discarded. 15

16 In the event of any queries please contact the system installer. Ensure this booklet is passed to the householder once installation & commissioning of the ventilation system is complete. This Product Manual must be kept in the Home Information Pack and used as a service record. Installed by: MARKETING DIVISION 894 The Crescent, Colchester Business Park, Colchester, CO4 9YQ Tel: +44 (0) Fax: +44 (0) ventsales@titon.co.uk Web: TITON DO 5581 Iss 02

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Purge Ventilation Unit. Product Manual. ventilation systems TP625 EN Purge Ventilation Unit TP625 Product Manual ventilation systems Warnings, Safety Information and Guidance Important Information Important: read these instructions fully before the installation of this

More information

Warnings, Safety Information and Guidance

Warnings, Safety Information and Guidance EN SR700 SRHRV Fan TP600 Single Room Heat Recovery Ventilation Fan Unit SRC Controller TP590 Single Room Heat Recovery Ventilation Controller Unit Product Installation Manual ventilation systems Warnings,

More information

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

Titon CME1 Q Plus Mechanical Extract Ventilation Unit Titon CME1 Q Plus Mechanical Extract Ventilation Unit Product Manual ventilation systems 2 PCT Patent Application No PCT/GB2009/000114 Contents This is the Product Manual for the Titon CME1 Q Plus Introduction...................................

More information

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon Quadra Centrifugal Fan Lo-Carbon Quadra Centrifugal Fan Installation and Wiring Instructions Stock Ref. N Quadra TP Quadra TM Quadra HTP 439251A 439253A 439181A 220-240V~50Hz IPX4 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH

More information

Silhouette Installation and Wiring Instructions

Silhouette Installation and Wiring Instructions Silhouette Installation and Wiring Instructions Stock Ref. N 45 40 55B (100B) 44 51 61 (125B) 45 40 59B (150X) 45 40 56B (100T) 44 51 62 (125T) 45 40 60B (150XT) 45 40 57B (100HT) 44 51 63 (125HT) 45 40

More information

aura-t TP536/GBR ventilation systems

aura-t TP536/GBR ventilation systems EN aura-t TP536/GBR Product Manual HRV controller ventilation systems Warnings, Safety information and Guidance Important Information Read instructions fully before the installing this appliance. 1. This

More information

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units Product Manual ventilation systems 2 PCT Patent Application No PCT/GB2009/000114 Contents Introduction...................................

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. VA100 Lo-Carbon RANGE 100mm AXIAL EXTRACT FAN Installation and Wiring Instructions Stock Ref. N 44 31 59 - LP 44 31 60 - XP 44 31 61 - LT 44 31 62 - XT 44 31 63 - LHTP 44 31 64 - XHTP 220-240V~50Hz PLEASE

More information

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz VA 150 A, VA 150 P WINDOW EXTRACT FAN Installation and Wiring Instructions VA150 P STOCK Ref: 152110B VA150 A STOCK Ref: 153110B 220-240V/1/50Hz READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE

More information

Heat Recovery Ventilation Units. LED Status Indicator. Product Manual. ventilation systems. auralite compatible HRV units

Heat Recovery Ventilation Units. LED Status Indicator. Product Manual. ventilation systems. auralite compatible HRV units EN auralite compatible HRV units aurastat compatible HRV units H200 Q Plus ECO 204x60 H200 Q Plus ECO Ø150 H200 Q Plus ECO Ø160 TP451HMB TP452HMB TP453HMB H200 Q Plus ECO 204x60 H200 Q Plus ECO Ø150 H200

More information

G Installation manual Solitude - dmev unit

G Installation manual Solitude - dmev unit G G Installation manual Solitude - dmev unit Read this manual carefully before using the product and keep it in a safe place for reference. This product was constructed up to standard and in compliance

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS. Eclipse Installation and Wiring Instructions Models Eclipse 100X Eclipse 100XP Eclipse 100XT Eclipse 150X Eclipse 150XP Ref No. 42 73 10A 42 72 81A 42 72 82A 42 72 83A 42 73 13A 220-240V~50Hz PLEASE READ

More information

aura-t TP536/EU ventilation systems

aura-t TP536/EU ventilation systems EN aura-t TP536/EU Product Manual HRV controller ventilation systems Warnings, Safety information and Guidance Important Information Read instructions fully before the installing this appliance. 1. This

More information

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon Quadra Centrifugal Fan Lo-Carbon Quadra Centrifugal Fan Installation and Wiring Instructions Stock Ref. N Quadra TP Quadra TM Quadra HTP 439251A 439253A 439181A 220-240V~50Hz IPX4 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. Silhouette Installation and Wiring Instructions Stock Ref. N 45 40 55B (100B) 44 51 61 (125B) 45 40 59B (150X) 45 40 56B (100T) 44 51 62 (125T) 45 40 60B (150XT) 45 40 57B (100HT) 44 51 63 (125HT) 45 40

More information

Centrif Duo & Centrif Duo Plus

Centrif Duo & Centrif Duo Plus Centrif Duo & Centrif Duo Plus Installation and Wiring Instructions Stock Ref. N Centrif Duo P 25 61 20D Centrif Duo T 25 62 20D Centrif Duo DP 25 63 20D Centrif Duo HTP 25 64 20D Centrif Duo Centrif Duo

More information

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan Installation and Wiring Instructions Stock Ref. N 427485B (P) 427486B (T) 427487B (HT) 427488B (TM) FAN UNITS 12V DC SELV (CLASS III) CONTROLLERS

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. Silhouette Lo-Carbon RANGE 100/150mm AXIAL EXTRACT FAN Installation and Wiring Instructions Stock Ref. N 44 16 24-100B 44 16 25-100T 44 16 26-100HT 44 16 28-150B 44 16 29-150T 44 16 30-150HT 220-240V~50Hz

More information

Lo-Carbon SELV Tempra

Lo-Carbon SELV Tempra Lo-Carbon SELV Tempra THROUGH THE WALL HEAT RECOVERY FAN Installation and Wiring Instructions DRAFT Stock Ref. N 444368 Pullcord. (SVP) 444369 Timer. (SVT) 444370 Humidistat -Timer Pullcord. (SVHTP) 220-240V~50Hz

More information

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref. Lo-Carbon MULTIVENT MVDC-MS & VENTILATION SYSTEMS Installation and Wiring Instructions Stock Ref. N MVDC-MS 76A 98 0-0V~50Hz PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. PLEASE SAVE

More information

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

WHHR125DC Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use "WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor Installation, Operating and Maintenance Instructions domestic and commercial use Page 2 Contents Section Page Number Introduction 3 How

More information

HRV10 Q Plus TP440A TP440ABD TP440ABS. HRV10M Q Plus TP441A TP441ABD TP441ABS. Heat Recovery Ventilation Unit Product Manual

HRV10 Q Plus TP440A TP440ABD TP440ABS. HRV10M Q Plus TP441A TP441ABD TP441ABS. Heat Recovery Ventilation Unit Product Manual EN HRV10 Q Plus TP440A TP440ABD TP440ABS HRV10M Q Plus TP441A TP441ABD TP441ABS Heat Recovery Ventilation Unit Product Manual IMPORTANT - Fully read this Product Manual to help ensure the ventilation system

More information

Lo-Carbon Quadra SELV

Lo-Carbon Quadra SELV Lo-Carbon Quadra SELV Installation and Wiring Instructions Stock Ref. N Quadra SVTP 442865 Quadra SVHTP 442866 Quadra SVTM 442867 Safety Extra Low Voltage IPX7 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH

More information

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT. Integra Integra Plus EC MVHR Installation & Commissioning Stock Ref. N 437666EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT. Copyright 2009 Vent-Axia Limited. All rights reserved.

More information

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS. INSTALLATION/OPERATING INSTRUCTIONS FOR C100 & C100T Thank you for purchasing a quality Extractor fan from Greenbrook. Please read these instructions fully prior to initial use. Every effort has been made

More information

Installation & Operating Instructions

Installation & Operating Instructions Installation & Operating Instructions For 4 / 100mm Centrifugal s Models: K612 & K612T Thank you for purchasing a quality Centrifugal from GreenBrook. Please read these instructions fully prior to initial

More information

HR200WK Through the wall Heat Recovery Ventilator

HR200WK Through the wall Heat Recovery Ventilator HR200WK Through the wall Heat Recovery Ventilator Installation and Maintenance Instructions Stock Ref No:- HR200WK 14120020 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE

More information

WHHR Midi & Midi Lite

WHHR Midi & Midi Lite WHHR Midi & Midi Lite Residential Whole House Heat Recovery Units with Low Energy EC Motors Optional - Integral LCD Installation, Operating and Maintenance Instructions Image of model with LCD screen Page

More information

Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12

Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12 Vent-Axia Svara Multifunctional app controlled fan Important Information 2 Installation and Wiring Instructions 3- Accessories 2 Pin Code 2 6 2 Ø99 Ø77 Important: READ THESE INSTRUCTIONS BEFORE COMMENCING

More information

CMX-S. Company name: Contact: Tel: Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions

CMX-S. Company name: Contact: Tel:   Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions V EN T IL AT ION V EN T IL AT ION CMX-S Installer contact details: Company name: Contact: Tel: Email: Central Mechanical Extract Ventilation (cmev) appliance Installation and Operating Instructions These

More information

VA100 SELV 12 RANGE. Installation and Wiring Instructions IPX7

VA100 SELV 12 RANGE. Installation and Wiring Instructions IPX7 VA100 SEV 12 RAGE Installation and Wiring Instructions Stock Ref. VA100SV12 VA100SVX12 VA100SVXT12 VA100SVH12 VA100SVXH12 VA100SVXHT12 25 81 10D 25 83 10D 25 84 10D 25 81 12E 25 83 12E 25 85 12B FA UITS

More information

Xpelair Simply Silent TM Contour Fan

Xpelair Simply Silent TM Contour Fan Xpelair Simply Silent TM Contour Fan Installation and Maintenance Instructions C4S (92960AW) / C4R (92961AW) C4TS (92962AW) / C4TR (92963AW) C4PS (92964AW) / C4PR (92965AW) C4HTS (92966AW) / C4HTR (92967AW)

More information

Green Line CMX. Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions. Model: CMX

Green Line CMX. Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions. Model: CMX Green Line CMX Central Mechanical Extract Ventilation (cmev) appliance Installation and Operating Instructions Model: CMX These instructions must be given to the householder DO NOT SWITCH OFF THE UNIT

More information

Installation & Operating Instructions

Installation & Operating Instructions Installation & Operating Instructions For 12V Extractor s Models: (4 ) G510SELV, (6 ) G242SELV For 12V Controllers Models: 12VFC, 12VFCT & 12VFCHS Thank you for purchasing a quality 12V Extractor & Controller

More information

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions ELIX 1003 Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions 3 speed continuous running SAP Appendix Q Eligible 3 models: - standard - timer - humidity control for all

More information

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions Commissioning Data: To be completed by the Commissioning Engineer. Refer to User/Homeowner Guide

More information

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2 INTEGRA PLUS Installation and Wiring Instructions Stock Ref. N INTEGRA PLUS 437666 230V~ 50Hz ABC PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS. IPX2 VENT-AXIA

More information

CG60/ 70/ 80/ 90/ 100 SS/BK

CG60/ 70/ 80/ 90/ 100 SS/BK CG60/ 70/ 80/ 90/ 100 SS/BK GB IE [01] x 1 [02] x 1 [03] x 1 [04] x 2 [05] x 1 [06] x 1 [07] x 1 [08] x 4 [09] x 4 [10] x 1 [11] x 6 1 : 1 [12] x 4 [13] x 6 (3.9 x 32mm) [14] x 4 (3.4 x 10mm) CG60/ 70/

More information

18 INCH HIGH VELOCITY FLOOR FAN

18 INCH HIGH VELOCITY FLOOR FAN 18 INCH HIGH VELOCITY FLOOR FAN MODEL NO: CFF18B100 PART NO: 3231530 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0917 - ISS 1 INTRODUCTION Thank you for purchasing this CLARKE 18 inch

More information

Xpelair Simply Silent TM DX100 Fan

Xpelair Simply Silent TM DX100 Fan Xpelair Simply Silent TM DX100 Fan Installation and Maintenance Instructions DX100R (93005AW) / DX100S (93025AW) DX100TR (93006AW) / DX100TS (93026AW) DX100PR (93007AW) / DX100PS (93027AW) DX100HTR (93008AW)

More information

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit DC Heat Recovery Unit MVHR Wholehouse heat recovery unit Stock Ref. N DC Heat Recovery Unit MVHR 443423 Installation, Maintenance & Users Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

More information

Simply Silent Contour 4 (100mm) Axial Extraction Fan

Simply Silent Contour 4 (100mm) Axial Extraction Fan Simply Silent Contour 4 (100mm) Axial Extraction Fan Suitable for bathrooms, toilets, shower and utility rooms Controls humidity, odours and mould growth Sleek low-profile design, wall or ceiling mounting

More information

User and maintenance manual

User and maintenance manual GB User and maintenance manual IMPORTANT SAFETY INSTRUCTIONS These instructions shall also be available on website: docs.whirlpool.eu. YOUR SAFETY AND THAT OF OTHERS IS HIGHLY IMPORTANT. This manual and

More information

Section HMB/HMBE. Section B/BE. Heat Recovery Ventilation Units. LED Status Indicator. Product Manual. ventilation systems

Section HMB/HMBE. Section B/BE. Heat Recovery Ventilation Units. LED Status Indicator. Product Manual. ventilation systems EN Section HMB/HMBE auralite compatible HRV units Section B/BE aurastat and auramode compatible HRV units HRV1.25 Q Plus ECO HRV1.35 Q Plus ECO HRV1.75 Q Plus ECO HRV2 Q Plus ECO HRV2.85 Q Plus ECO HRV3

More information

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans Installation and Maintenance IPX4* The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU 1.0 SAFETY INFORMATI The installation

More information

Lo-Carbon PoziDry Pro

Lo-Carbon PoziDry Pro Lo-Carbon PoziDry Pro Positive Input Ventilation Unit Installation and Wiring Instructions Stock Ref. N 476310 PoziDry Pro 476311 PoziDry Pro with Heater 476312 PoziDry Pro FD 220-240V~50Hz PLEASE READ

More information

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book USER GUIDE IMAX XTRA EL 320-620kW For Installation Guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. Centra o-carbon COTIUOUS EXTRACT FA Installation and Wiring Instructions Stock Ref. 44 29 54 Timer (T) 44 29 55 Humidistat-Timer (HT) 44 30 45 Humidistat-Timer- Pullcord. (HTP) 220-240V~50Hz PEASE READ

More information

Xpelair Simply Silent DX150

Xpelair Simply Silent DX150 English Xpelair Simply Silent DX150 Installation and Maintenance Instructions DX150S (93070AW) DX150R (93071AW) DX150TS (93072AW) DX150TR (93073AW) DX150PS (93074AW) DX150PR (93075AW) DX150HTS (93076AW)

More information

ART cm Island Curved Glass

ART cm Island Curved Glass ART28101 90cm Island Curved Glass [01] x 1 [02] x 1 [03] x 1 [04] x 1 [05] x 4 [06] x 1 [07] x 1 [08] x 1 [09] x 4 [10] x 4 [11] x 1 [12] x 4 (6x70mm) [13] x 4 (6.3x17x2mm) [14] x 8 (4x12x1mm) [15] x 4

More information

ELTA FANS IN-LINE MIXED FLOW FAN IMF100 / 125 / 150 / 200 INCLUDING MODELS WITH BUILT-IN-RUN-ON TIMERS T

ELTA FANS IN-LINE MIXED FLOW FAN IMF100 / 125 / 150 / 200 INCLUDING MODELS WITH BUILT-IN-RUN-ON TIMERS T ELTA FANS IN-LINE MIXED FLOW FAN IMF100 / 125 / 150 / 200 INCLUDING MODELS WITH BUILT-IN-RUN-ON TIMERS T Installation and Maintenance Instructions. THESE INSTRUCTIONS MUST BE READ FULLY BEFORE COMMENCING

More information

Xcell 270 Longlife DC wholehouse heat recovery unit

Xcell 270 Longlife DC wholehouse heat recovery unit Xcell 270 Longlife DC wholehouse heat recovery unit Installation and maintenance instructions Xpelair Xcell 270 Longlife DC wholehouse heat recovery unit Xcell 270, Xcell 270BP Please leave this leaflet

More information

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER Heat 45 & 55 User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER CE/PI No. 86-CN-69 Heat 45 - GC No. 41-930-40 Heat 55 - GC No. 41-930-41 These instructions

More information

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use Internal/External Wall/Window Fan Range GX6 Installation and maintenance instructions Retain for future use A GLASS WINDOW B C D ( 6 see F ) 13 E1 E2 E3 G1 G2 G3 G4 H I GB Xpelair GX6, GXC6, GXC6T, GX6HT

More information

200W Frostwatch Radiant Heater Operation Manual

200W Frostwatch Radiant Heater Operation Manual LEVFW200 200W Frostwatch Radiant Heater Operation Manual REMOVE ALL PACKAGING MATERIALS FROM THIS PRODUCT BEFORE USING IT LEVFW200 200W Frostwatch Radiant Heater IMPORTANT: Read these instructions fully

More information

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions Commissioning Data: To be completed by the Commissioning Engineer. Refer to User / Homeowner Guide also supplied.

More information

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans Installation and Maintenance IPX4* The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU 1.0 SAFETY INFORMATION

More information

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Installation and Maintenance Instructions Retain for future reference 3. To remove the impeller, unscrew the central screw with a 7mm nut runner

More information

HRX-aQ Range. Mechanical Ventilation with Heat Recovery appliances. Installation and Operating Instructions

HRX-aQ Range. Mechanical Ventilation with Heat Recovery appliances. Installation and Operating Instructions HRX-aQ Range Mechanical Ventilation with Heat Recovery appliances Installation and Operating Instructions Models: AQH200-S, AQH200-B, AQH240-S, AQH240-B These instructions must be given to the householder

More information

Xpelair Simply Silent DX100

Xpelair Simply Silent DX100 Xpelair Simply Silent DX100 English Nederlands Installation n and Maintenance Instructions Installa en Onderho ru DX100R (93005AW) DX100S (93025AW) DX100TR (93006AW) DX100TS (93026AW) DX100HPTR (93009AW)

More information

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR Whole House Mechanical Ventilation with Heat Recovery - MVHR WHHR125DC - Aera This MVHR - WHHR125DC - Aera - is an efficient, low energy solution to controlling condensation and pollution. It provides

More information

100cm Chimney Hood GB IE

100cm Chimney Hood GB IE 100cm Chimney Hood GB IE [01] x 1 [02] x 2 [03] x 2 [04] x 2 [05] x 3 [06] x 1 [07] x 1 1 : 1 [09] x 8 (3.9 x 32mm) [08] x 8 [10] x 4 (4 x 12mm) 100cm Chimney Hood GB IE Cooker Hood 04 FR Hotte Aspirante

More information

KADO LUX LED EXHAUST FAN 200

KADO LUX LED EXHAUST FAN 200 page 1 of 5 272mm 240mm 170mm 272mm 221mm 98mm Dimensions are nominal measurements only. SPECIFICATIONS Recommended use Material Colour availability Fascia Size Weight Domestic, Hotel and Commercial ABS

More information

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or Domestic AC Fans 230V Installation and Operating Guide 230V AC Base Models: ico15 72683501 ico15c 72591501 ico30 72591601 ico60 72591701 ico Domestic Fan 230V Installation, Maintenance and Use ico Domestic

More information

5KW ELECTRIC FAN HEATER

5KW ELECTRIC FAN HEATER 5KW ELECTRIC FAN HEATER MODEL NO: DEVIL 7005 PART NO: 6935452 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product,

More information

USER MANUAL. ICON60H Version 00. Vertical Glass Hood

USER MANUAL. ICON60H Version 00. Vertical Glass Hood USER MANUAL ICON60H Version 00 Vertical Glass Hood [02] x 1 [01] x 1 [03] x 1 [04] x 1 [07] x 1 [05] x 1 [08] x 9 [06] x 1 [09] x 9 (4 x 30mm) [10] x 2 (3 x 10mm) Cooker hood Let's get started... These

More information

Installation and Maintenance

Installation and Maintenance 1.0 INTRODUCTION MRXBOXAB-ECO-LP1 (Standard Unit) MRXBOXAB-ECO-LP1-OH (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery for Ceiling Void Mounting Installation and Maintenance The LP1

More information

VENT TREX. Product Guide

VENT TREX. Product Guide Product Guide Product Guide Contents Page Contents 1 Catalogue page 2 Case study Manchester City Council 2003 3 Case study LB Southwark 2006 4 EC Declaration Of Conformity 5 Specifier s text 6 Pricing/order

More information

Xpelair Simply Silent DX100B

Xpelair Simply Silent DX100B Xpelair Simply Silent DX100B Installation and Maintenance Instructions English DX100BR (92997AW) DX100BS (93017AW) DX100BTR (92998AW) DX100BTS (93018AW) DX100BHTR (92999AW) DX100BHTS (93019AW) DX100BHPTR

More information

HOTLINE:

HOTLINE: You are about to install a product that is designed to outlast the life-cycle of the building. Once installed the unit will operate continuously for 5 years and beyond without a major service. Please therefore

More information

ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models:

ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models: ELEGANCE Low Carbon Fan with EC Motor Installation and Operating Instructions 6 models: - SAP Appendix Q Eligible 3 speed continuous running - timer - humidity control - SELV - low voltage for all domestic

More information

Installation and Maintenance

Installation and Maintenance 1.0 INTRODUCTION MRXBOXAB-ECO-LP1SW (Standard Unit) MRXBOXAB-ECO-LP1-OHSW (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery for Ceiling Void Mounting Installation and Maintenance The

More information

GB User and maintenance manual

GB User and maintenance manual GB User and maintenance manual IMPORTANT SAFETY INSTRUCTIONS These instructions shall also be available on website: docs.whirlpool.eu. YOUR SAFETY AND THAT OF OTHERS IS VERY IMPORTANT This manual and

More information

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER Safety IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION CHECK LIST Make

More information

1500W Black Glass Portable Electric Panel Heater KAHTP20BLKA

1500W Black Glass Portable Electric Panel Heater KAHTP20BLKA 1500W Black Glass Portable Electric Panel Heater KAHTP20BLKA Attention Please handle this product with care and inspect it regularly to ensure it is in good working order. If the product, power supply

More information

Lucci Designer Hi Flow Exhaust Fan

Lucci Designer Hi Flow Exhaust Fan USE AND CARE INSTRUCTION INSTALLATION INSTRUCTION Lucci Designer Hi Flow Exhaust Fan SKU# 200265&200267 MXSQ8PW(200mm) SKU# 200266&200268 MXSQ10PW(250mm) Dear Customers, Thank you for selecting a LUCCI

More information

Installation and Maintenance

Installation and Maintenance MRXBOX95B-LP1 (Standard Unit) MRXBOX95B-LP1-OH (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Ceiling Void Mounting Installation and Maintenance The EMC Directive

More information

EVP61/91/101/121. Extractor. Installation, use and maintenance.

EVP61/91/101/121. Extractor. Installation, use and maintenance. EVP61/91/101/121 Extractor Installation, use and maintenance www.cda.eu Important The manufacturer cannot be held responsible for injuries or losses caused by incorrect use or installation of this product.

More information

USER MANUAL DOWN-DRAFT HOOD. UBDDCHC60_90A, UBDDCHC60_90ABK Version 02

USER MANUAL DOWN-DRAFT HOOD. UBDDCHC60_90A, UBDDCHC60_90ABK Version 02 USER MANUAL DOWN-DRAFT HOOD UBDDCHC60_90A, UBDDCHC60_90ABK Version 02 GB IE [01] x 1 VENT PACK Ø150mm [09] x 1 [10] x 1 IE Getting started... GB Safety These instructions are for your safety. Please read

More information

CAN60 / CAN60SV _01 CAN60_CAN60SV. WARNING: Read the instructions before using the appliance.

CAN60 / CAN60SV _01 CAN60_CAN60SV. WARNING: Read the instructions before using the appliance. CAN60 / CAN60SV 60901870_01 CAN60_CAN60SV GB IE WARNING: Read the instructions before using the appliance. [01] x 1 [02] x 1 [03] x 2 [04] x 1 1 : 1 [05] x 4 (4x 32mm) [6] x 2 (3x 12mm) Cooker hood GB

More information

3KW ELECTRIC FAN HEATER

3KW ELECTRIC FAN HEATER 3KW ELECTRIC FAN HEATER MODEL NO: DEVIL 7003 PART NO: 6935452 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product,

More information

15KW ELECTRIC FAN HEATER

15KW ELECTRIC FAN HEATER 15KW ELECTRIC FAN HEATER MODEL NO: DEVIL 7015 PART NO: 6935456 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product,

More information

D100, D125 & D150. Installation Instructions

D100, D125 & D150. Installation Instructions D100, D125 & D150 Installation Instructions 100mm 125mm 150mm 34 l/s (124 m 3 /h) 50 l/s (180 m 3 /h) 61 l/s (277 m 3 /h) IP22/IP24 IP22 IP22 40W 60W 20W 23W 25W 40 C 40 C 40 C kg 1.3 kg 1.4 kg 1.5 kg

More information

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3 EKF EC kitchen extract fan range Installation and Wiring Instructions Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS.

More information

Installation and Maintenance

Installation and Maintenance 38 70 = 100 410 = 60 1.0 INTRODUCTION MRXBOXAB-ECO4-AESW (Standard Unit) MRXBOXAB-ECO4-AEOHSW (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for Wall Mounting Installation and Maintenance

More information

2 KW OIL FILLED RADIATOR

2 KW OIL FILLED RADIATOR This product is only suitable for well insulated spaces or occasional use. 2 KW OIL FILLED RADIATOR MODEL NO: OFR9/200 PART NO: 6934005 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0618

More information

30KW ELECTRIC FAN HEATER

30KW ELECTRIC FAN HEATER 30KW ELECTRIC FAN HEATER MODEL NO: DEVIL 7030 PART NO: 6935458 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product,

More information

ISCG90SS _03 ISCG90SS

ISCG90SS _03 ISCG90SS ISCG90SS 60900355_03 ISCG90SS GB IE [01] x 1 [02] x 1 [03] x 1 [04] x 8 [05] x 1 [06] x 4 [07] x 1 [08] x 1 [09] x 1 [10] x 4 [11] x 4 [12] x 1 [13] x 4 (6x70mm) [14] x 8 (6.3x17x2mm) 1 : 1 [15] x 4 (3.9x18mm)

More information

Hand Dryer Installation & User Manual

Hand Dryer Installation & User Manual Hand Dryer Installation & User Manual Please read instructions in conjunction with the illustrations Please save these instructions. Safety & Guidance notes Important:- Read all these instructions before

More information

Installation and Maintenance

Installation and Maintenance 1.0 Introduction MRXBOX-ECO2 (Standard Unit) MRXBOX-ECO2-OH (Opposite hand Unit) MRXBOXAB-ECO2 (Standard Unit) MRXBOXAB-ECO2-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for

More information

Installation and Operating Manual Drying Cabinet

Installation and Operating Manual Drying Cabinet Drying Cabinet TS-4175 WW CONTENTS THIS USER MANUAL & DATA PLATE DETAILS Page 2 IMPORTANT SAFETY INSTRUCTIONS Page 3 INSTALLATION INSTRUCTIONS Page 4 OPERATING INSTRUCTIONS Page 8 MAINTENANCE INSTRUCTIONS

More information

Green Line HRX. Mechanical Ventilation with Heat Recovery appliance. Installation and Operating Instructions

Green Line HRX. Mechanical Ventilation with Heat Recovery appliance. Installation and Operating Instructions Green Line HRX Mechanical Ventilation with Heat Recovery appliance Installation and Operating Instructions Models: HRX-S, HRX-B, HRX-FP, HRX-BFP, HRX-FS, HRX-FB, HRX-FFP and HRX-FBFP These instructions

More information

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual 90000556/90000557 Issue 10 9/17 MODEL: DV72 R & L Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual Commissioning Data: to be completed by the installer Date of installation:

More information

User Instruction Manual

User Instruction Manual User Instruction Manual 4 & 6 Slot Toasters This covers the Burco 4 & 6 slot toasters TSSL14 & TSSL16 444440355 & 444440356 Red End Cap 4 slot 444440606 Red End Cap 6 slot 444440608 Cream End Cap 4 slot

More information

Heated Display Merchandiser. Instruction Manual. Models: GC875-A / GC876-A / GC877-A

Heated Display Merchandiser. Instruction Manual. Models: GC875-A / GC876-A / GC877-A Heated Display Merchandiser Instruction Manual Models: GC875-A / GC876-A / GC877-A Safety Tips Position on a flat, stable surface. A service agent/qualified technician should carry out installation and

More information

irconcentre.co.uk airooncentre.co.uk

irconcentre.co.uk airooncentre.co.uk Installation and maintenance instructions DX100 Standard DX100PC Pull Cord DX100T Timer DX100H Humidistat DX100HP Humidistat and Pull Cord DX100PIR Integral Body Movement Sensor DX100VTD Delay Timer Toilet/Bathroom

More information

Wiring the fan correctly...

Wiring the fan correctly... You are about to install a product that is designed to outlast the life-cycle of the building. Once installed the unit will operate continuously for 7 years and beyond without a major service. Please therefore

More information

Instructions for use

Instructions for use Instructions for use These instruction shall be available on website docs.kitchenaid.eu Important instructions for safety 4 Installation 6 Safeguarding the environment 6 Troubleshooting guide 7 After-Sales

More information

EDD61 & EDD91 Extractors

EDD61 & EDD91 Extractors EDD61 & EDD91 Extractors Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu

More information

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

Model: Kair Whole House Ventilator Model Number: KHRVWH2000 Model: Kair Whole House Ventilator Model Number: KHRVWH2000 Installation, Maintenance Instructions and User Guide Unit 6 Chiltonian Industrial Estate 203 Manor Lane, Lee, London. SE12 0TX Tel: 08451 60

More information