Ultrasonic Switches. Features & Benefits

Size: px
Start display at page:

Download "Ultrasonic Switches. Features & Benefits"

Transcription

1 Why use an ultrasonic switch over other level technologies? Depending upon your application, there may be three or four technologies equally suited for your application; however; only one will be the best choice when considering its features and benefi ts. Ultrasonic switches are a cost-effective solution for your applications. Installation requires mounting the sensor (threaded or fl anged) to the vessel, connecting the power and control wires, and applying power. There is no additional set-up or calibration required. Since it is an electronic instrument with no moving parts, preventive maintenance is limited to an annual visual inspection. The only recommended spare part is the board at a quantity of one board for every 10 units. A technician with basic electrical skills (wiring) can service the instrument. Features & Benefits Cost In addition to the price of the instrument, you must consider the cost of installation, set-up and calibration. Maintenance You need to factor in the frequency of preventative maintenance. Also, consider the cost of keeping key spare parts on the shelf. Skill What skill level is required of your maintenance personnel to service the instrument. Registered Quality System to ISO 9001:2000 1/24

2 Applications Ultrasonic switches are simple to apply and use. There are only a few limitations to their use: The media must be liquid Process temperature between -40 and 250 o F (-40 to 121 o C) The media must have less than 5% suspended solids No aeration in fl uids with a viscosity of 100cP (30W motor oil) or greater The following chart will assist you in selecting the right product for your application. Single-Point Sensing Line Power Loop Power Integral Mount Electronics Integral Mount Electronics with Sensor Monitor (Self-Test) Remote Mount Electronics Remote Mount Electronics with Sensor Monitor (Self-Test) 701 Pages Pages Pages Pages Pages Pages Pages Pages Pages Pages 8-9 Dual-Point Sensing Line Power Loop Power Alarm or Pump Control Alarm or Pump Control with Sensor Monitor (Self-Test) 712 Pages Pages N/A N/A Principle An ultrasonic switch is a device that uses inaudible high-frequency sound (ultrasound) to detect the presence or absence of a liquid at a designated point. The device consists of an electronic control unit and a sensor. Ultrasonic level switches use the properties of sound transmission in vapor and liquids to detect liquid level. When sound travels in air, it loses a great deal of signal strength. When traveling in liquid, sound retains almost all of its signal strength. To detect liquid level, we must determine if there is a liquid or gas (air) in the gap. Since liquids have a higher density than gasses, it is easier to transmit sound through them. One side of the sensor gap transmits sound, the other side detects it. When liquid is present, a high amount of sound is received at the detection side. When gas (air) is present, a small amount of sound is received. The electronics detect this difference and switch a relay accordingly. 2/24 Registered Quality System to ISO 9001:2000

3 Principle Ultrasonic switch sensors contain two piezoelectric crystals, one transmits sound and one receives sound. Each crystal is mounted on one side of a gap in the metal sensor. The transmit crystal generates high frequency sound (1MHz to 3 MHz) that is directed across the gap to the receiver crystal. The receiver crystal converts the sound energy received into an electric signal, which is processed by the electronics to determine if the gap has liquid or air in it. The drawing below shows the basic construction of an ultrasonic level switch sensor. An electrical signal is sent to the transmit crystal, which causes it to vibrate and produce high frequency sound. The receive crystal converts the high frequency sound that strikes it to another electrical signal, which is sent back to the electronics for processing. The sound energy that makes it across the sensor gap is very weak in air, and becomes very strong in liquid. Transmit Receive Application Conditions Ultrasonic level switches can be used in a wide variety of applications without any calibration or setup. However, there are limitations to the types of process they will work in. The factors below must be taken into consideration before selecting an ultrasonic level switch for your application. Liquids only - the process media must be a liquid. The ultrasonic level switch cannot detect the difference between two gases or a gas and a solid. The even density of a liquid is required for proper detection. Clean liquids only - a liquid that has too high a percentage of solids will not transmit sound well enough to allow detection. Typically 5% suspended solids are the maximum amount allowed. The liquid must fl ow - an application where the liquid cannot drain out of the sensor gap will cause false alarms. If a liquid is too viscous to fl ow out of a 3/4 gap then the unit will not operate properly. Sometimes this can be solved by different mounting, but some liquids are just too viscous. No (or few) bubbles - especially in fl uids with a viscosity higher than 100cP (30W motor oil). Large bubbles in thick fl uids will block the sound signal from crossing the gap. Low viscosity fl uids can have a fairly large amounts of bubbles as they tend to be very small (Alka-Seltzer in water). If these guidelines are properly observed, the ultrasonic level switches will provide trouble-free operation without any calibration or periodic adjustment. Registered Quality System to ISO 9001:2000 3/24

4 Series 701 Single Point The Series 701 tip-sensitive ultrasonic switch is a single-point device designed for economical detection of clean liquids. There are no moving parts and no calibration. The 701 is available either integral or remote mounted. An optional time delay can be used to eliminate false alarms due to turbulence in the process. An optional fi eld selectable fail-safe switch is also available. The standard unit is set to High-level Failsafe (HLFS). Features No calibration required 10A DPDT relay output FM Approved or CSA Certifi ed for hazardous locations Line and loop powered versions 701 Single Point Product Specifications Input Power Line Fuses Loop Output Type Line Loop Loop Resistance Repeatability 120 VAC, 50/60 Hz 240 VAC, 50/60 Hz 24 VDC VDC Intrinsically Safe Field replaceable (line power only) 10A DPDT, 250 VAC 10A DPDT, 30 VDC DC rating shown for resistive loads 8mA (dry), 16 ma (Wet)-Standard 765 ohms 24 VDC (2mm) Maximum Current Draw (Line Power) 24 VDC 100 ma 120 VAC 35 ma 240 VAC 18 ma Response Time On Off Enclosure Environmental Rating Conduit Connection Maximum Remote Distance from Sensor Ambient Temperature Range 0 second 1 second NEMA 4X; IP65 3/4 NPT 50 feet (15.2 meters) -40 to 160 o F (-40 to 71 o C) Failsafe HLFS-Standard; field selectable is optional Process Temperature Range -40 to 250 o F (-40 to 121 o C) Maximum Process Pressure 2000 psig (138 bar) * See page 22 for sensor shipping weights. 4/24 Registered Quality System to ISO 9001:2000

5 Power Supply 24 VDC (K1 and R1 housings only) 120 VAC (K1 and R1 housings only) 240 VAC (K1 and R1 housings only) 24 VDC (Loop) (K4 and R4 housings only) Electrical Housing Integral Remote Integral (9 Power Only) Remote (9 Power Only) K1 R1 K4 R CS Al FM Fl BK FS OD OF PK RG PP RR Accessories 701 K1 U P7 C FS Model Number Registered Quality System to ISO 9001:2000 TT VV PY YY How to Order Model Number System 701-K1-U-P7-C-FS The Series 701 is comprised of two parts. The fi rst is the electronics and housing; the second is the sensor. Select the electronics and housings on this page and refer to pages 18 & 19 for the sensor model number. The housing dimensions can be seen on pages 14 & 15. When ordering a remote housing, order remote cable part number 300-XX-S (XX = length in feet). Orders must have complete model numbers, i.e. each component must have a designator. * Match sensor approvals to electronics approvals to maintain the agency listing integrity. Agency Approval CSA Certifi ed Explosion Proof* CSA Certifi ed Intrinsically Safe* (9 power only) (K4 housings only) FM Approved Explosion Proof* FM Approved Intrinsically Safe* (9 power only) (K4 housings only) Remote electronics fl at surface mounting bracket (R housings only) (see pages 14 & 15) Field selectable Failsafe switch (6, 7, 8 power only) On delay time (6, 7, 8 power only) (specify time from chart on page 16) Off delay timer (6, 7, 8 power only) (specify time from chart on page 16) Pipe mounting kit, BK accessory required (R housing only) (see pages 14 & 15) Gold-contact relay (6, 7, 8 power only) Fiber tag with customer specifi ed tag information SS nameplate wired to the unit with customer specifi ed tag information SS nameplate permanently affi xed to housing with customer specifi ed tag information Fungicidal varnish applied to housing exterior Powder coat epoxy coating applied to housing exterior Epoxy coating applied to housing exterior (200 hours - salt spray) Agency Safety Method Approval Model(s) FM Explosion Proof Class I, Groups C, D; Class II, Groups E, F, G; Class III, Division 1 701xx-U-Px-FM Intrinsically Safe Class I, Groups C, D; Class II, Groups E, F, G; Class III, Division 1 CSA Explosion Proof Class I, Groups C, D Class II, Groups E, F, G; Class III, Division 1 Intrinsically Safe Class I, Groups C, D Class II, Groups E, F, G; Class III, Division 1 701K4-U-P9-FI 701xx-U-Px-CS 701K4-U-P9-AI 5/24

6 Series 711 Single Point The Series 711 ultrasonic switch is a versatile single-point device designed for the detection of clean liquids. The 711 is available with a variety of sensor types to meet most process conditions. It is available integral or remote mounted and comes standard with fi eld-selectable failsafe. Features No calibration required Can be used with notch, epoxy and viscous type sensors FM Approved and CSA Certifi ed, for hazardous locations Field-selectable failsafe 711 Single Point Product Specifications Input Power 120 VAC, 50/60 Hz 240 VAC, 50/60 Hz 24 VDC Response Time On Off 250 msec 250 msec Output Type 10A DPDT, 250 VAC 10A DPDT, 30 VDC DC rating shown for resistive loads Enclosure Environmental Rating Conduit Connection NEMA 4X; IP65 3/4 NPT Repeatability Failsafe (2mm) Field-selectable Maximum Current Draw (Line Power) 24 VDC 140 ma 120 VAC 60 ma 240 VAC 30 ma Maximum Remote Distance 50 ft. (15.2 m) from Sensor Ambient Temperature Range Process Temperature Range -40 to 160 o F (-40 to 71 o C) -40 to 250 o F (-40 to 121 o C) Maximum Process Pressure 2000 psig (138 bar) *See page 22 for sensor shipping weights. 6/24 Registered Quality System to ISO 9001:2000

7 Process Connection Power Supply Electrical Housing Probe Type Notch Viscous N V How to Order Model Number System 711-K1-N-P6-C-PP The Series 711 is comprised of two parts. The fi rst is the electronics and housing; the second is the sensor. Select the electronics and housings on this page and refer to pages 18 & 19 for the sensor model number. The housing dimensions can be seen on pages 14 & 15. When ordering a remote housing, order remote cable part number 300-XX-S (XX = length in feet). Orders must have complete model numbers, i.e. each component must have a designator. * Match sensor approvals to electronics approvals to maintain the agency listing integrity. Integral Remote 1 K R 24 VDC VAC VAC C G Sensor Material Metal Tefl on (N Probe Only) Accessories 711 K1 N P 6 C PP Model Number 5 CS FM BK PK RG PP RR TT VV PY YY CSA Certifi ed Explosion Proof* FM Approved Explosion Proof* Remote electronics fl at surface mounting bracket (R housing only) (see pages 14 & 15) Pipe mounting kit, BK accessory required (R housing only) (see pages 14 & 15) Gold-contact relay (6, 7, 8 power only) Fiber tag with customer specifi ed tag information SS nameplate wired to the unit with customer specifi ed tag information SS nameplate permanently affi xed to housing with customer specifi ed tag information Fungicidal varnish applied to housing exterior Powder coat epoxy coating applied to housing exterior Epoxy coating applied to housing exterior (200 hours - salt spray) Agency Approvals Agency Safety Method Approval Model(s) FM Explosion Proof Class I, Groups C, D; Class II, Groups E, F, G; Class III, Division 1 711x1-N-Px-FM CSA Explosion Proof Class I, Groups C, D Class II, Groups E, F, G; Class III, Division 1 711x1-N-Px-CS Registered Quality System to ISO 9001:2000 7/24

8 The Series 721 ultrasonic switch is an advanced single-point device designed to meet your needs for overfi ll protection. In addition to the features of the 711, the 721 includes a Sensor Monitor. This circuit continuously tests the functionality of the electronics and sensor. The Sensor Monitor Relay de-energizes if a fault is detected. The 721 is available with a variety of sensor types to meet most process conditions. It is available integral or remote mounted and comes standard with fi eld-selectable failsafe. Features No calibration required Continuous self-test (sensor monitor) verifi es operation FM or CSA Certifi ed for hazardous locations Field-selectable failsafe On/Off time delay is standard 721 Single Point Series 721 Single Point Product Specifications Input Power Line 120 VAC, 50/60 Hz 240 VAC, 50/60 Hz 24 VDC Maximum Current Draw (Line Power) 24 VDC 220 ma 120 VAC 60 ma 240 VAC 30 ma Loop Output Type Line Alarm Sensor Monitor Loop Alarm Sensor Monitor Loop Resistance VDC (Intrinsically safe) 10A DPDT, 250 VAC 10A DPDT, 30 VDC DC rating shown for resistive loads 10A DPDT, 250 VAC 10A DPDT, 30 VDC DC rating shown for resistive loads 8 ma (Dry), 16 ma (Wet) 5 ma or 19 ma; Field selectable 650 ohms 24 VDC Response Time (Line Power) On Off Response Time (Loop Power) On Off Time Delay Enclosure Environmental Rating Conduit Connection 250 msec 250 msec 0.5 seconds 5 seconds 0-30 seconds NEMA 4X; IP65 3/4 NPT Maximum Remote Distance 50 ft. (15.2 m) from Sensor Ambient Temperature Range -40 to 160 o F (-40 to 71 o C) Repeatability Failsafe (2mm) Field-selectable Process Temperature Range Maximum Process Pressure -40 to 250 o F (-40 to 121 o C) 2000 psig (138 bar) *See page 22 for sensor shipping weights. 8/24 Registered Quality System to ISO 9001:2000

9 How to Order Model Number System 721R2-N-P7-C-FM The Series 721 is comprised of two parts. The fi rst is the electronics and housing; the second is the sensor. Select the electronics and housings on this page and refer to page 18 for the sensor model number. The housing dimensions can be seen on pages 14 & 15. When ordering a remote housing, order remote cable part number 300-XX-S (XX = length in feet). Orders must have complete model numbers, i.e. each component must have a designator. Process Connection Sensor Material Electrical Housing Probe Type Integral Remote Power Supply 24 VDC VAC VAC 8 24 VDC (Loop) 9 Notch Viscous 1 K R 2 N V Metal Tefl on 3 4 C G 5 CS Al FM Fl BK PK RG PP RR TT VV PY YY Accessories CSA Certifi ed Explosion Proof* CSA Certifi ed Intrinsically Safe (9 power only) (N probe only) (K housing only) FM Approved Explosion Proof* FM Approved Intrinsically Safe* (9 power only)(n Probe only) (K housing only) Remote electronics fl at surface mounting bracket (R housing only) (see pages 14 & 15) PK Pipe mounting kit, BK accessory required (R housing only) (see pages 14 & 15) Gold-contact relay (6, 7, 8 power only) Fiber tag with customer specifi ed tag information SS nameplate wired to the unit with customer specifi ed tag information SS nameplate permanently affi xed to housing with customer specifi ed tag information Fungicidal varnish applied to housing exterior Powder coat epoxy coating applied to housing exterior Epoxy coating applied to housing exterior (200 hours - salt spray) 721 R 2 N P 7 C FM Model Number Agency Approvals Agency Safety Method Approval Model(s) FM Explosion Proof Class I, Groups C, D; 721x2-N-Px-FM Class II, Groups E, F, G; Class III, Division 1 Intrinsically Safe Class I, Groups C, D; 721K2-N-P9-FI Class II, Groups E, F, G; Class III, Division 1 CSA Explosion Proof Class I, Groups C, D 721x2-N-Px-CS Class II, Groups E, F, G; Class III, Division 1 Intrinsically Safe Class I, Groups C, D 721K2-N-P9-AI Class II, Groups E, F, G; Class III, Division 1 Registered Quality System to ISO 9001:2000 9/24

10 Series 712 Dual Point (Without Self-Test) The Series 712 ultrasonic switch is a versatile dual-point designed for the detection of clean liquids. The dual-output can be used as independent alarm points or used in tandem to provide pump control. It is available integral or remote mounted and comes standard with fi eld-selectable failsafe. Features No calibration required Optional pump control logic available FM and CSA Certifi ed for hazardous locations Field-selectable failsafe 712 Dual Point Product Specifications Input Power Line Output Type Repeatability Failsafe 120 VAC, 50/60 Hz 240 VAC, 50/60 Hz 24 VDC (2) 10A DPDT, 250VAC (2) 10A DPDT, 30VDC DC rating shown for resistive loads (2mm) Field-selectable Enclosure Environmental Rating Conduit Connection NEMA 4X; IP65 1 NPT Maximum Remote Distance 50 ft. (15.2 m) from Sensor Ambient Temperature Range Process Temperature Range -40 to 160 o F (-40 to 71 o C) -40 to 250 o F (-40 to 121 o C) Maximum Current Draw 24 VDC 280 ma 120 VAC 120 ma 240 VAC 60 ma Response Time (Line Power) On Off 250 msec 250 msec Maximum Process Pressure Shipping Weight* 2000 psig (138 bar) 7 lbs. (3.2 kg) lbs. (4.8 kg) for cast iron housing + 2 lbs. (1 kg) for remote *See page 22 for sensor shipping weights. 10/24 Registered Quality System to ISO 9001:2000

11 Model Number System 712K3-N-P6-C-YY 712 ultrasonic switch with integral housing, 240VAC power supply, with optional epoxy coating. How to Order The 712 is comprised of two parts. The fi rst is the electronics and housing; the second is the sensor. Refer to page 19 for the sensor model number. Electrical Housing Integral (Aluminum) Integral (Cast Iron) Remote (Aluminum) (order remote cable part number 300-XX-D, XX = length in feet) 2 Power Supply 24 VDC VAC VAC 8 1 K L R 2 3 CS FM PL BK PK RG PP RG RR TT VV PY YY Accessories CSA Certifi ed Explosion Proof* FM Approved Explosion Proof* (except L3 housing) Pump logic (see page 22 for function and ratings) Remote electronics fl at surface mounting bracket (R housing only)(see page 19) Pipe mounting kit, BK accessory required (R housing only)(see page 19) Gold-contact relay (6, 7, 8 power only) Fiber tag with customer specifi ed tag information Gold-contact relay (6, 7, 8 power only) SS nameplate wired to the unit with customer specifi ed tag information SS nameplate permanently affi xed to housing with customer specifi ed tag information Fungicidal varnish applied to housing exterior Powder coat epoxy coating applied to housing exterior Epoxy coating applied to housing exterior (200 hours - salt spray) 712 K 3NP 6 C YY Model Number Agency Approvals Agency Safety Method Approval Model(s) FM Explosion Proof Class I, Groups B, C, D; Class II, Groups E, F, G; Class III, Division 1 Class I, Groups C, D; Class II, Groups E, F, G; Class III, Division 1 CSA Explosion Proof Class I, Groups C, D Class II, Groups E, F, G; Class III, Division 1 Class I, Groups C, D Class II, Groups E, F, G; Class III, Division 1 712K3-N-Px-FM 712R3-N-Px-FM 712K3-N-Px-CS 712L3-N-Px-CS 712R3-N-Px-CS Registered Quality System to ISO 9001: /24

12 Series 722 Dual Point The Series 722 ultrasonic switch is an advanced dual-point device designed to meet your needs for sump/pump control. In addition to the features of the 712, the 722 includes a Sensor Monitor. This circuit continuously tests the functionality of the electronics and sensor (both gaps). The Sensor Monitor Relay de-energizes if a fault is detected. It is available integral or remote mounted and comes standard with fi eldselectable failsafe and time delay. Features No calibration required Continuous self-test (sensor monitor) verifi es operation of the unit FM and CSA Certifi ed for hazardous locations Field-selectable failsafe On/Off time delay is standard 722 Dual Point Product Specifications Input Power Line Output Type Alarm Repeatability Sensor Monitor 120 VAC, 50/60 Hz 240 VAC, 50/60 Hz 24 VDC (2) 10A DPDT, 250 VAC (2) 10A DPDT, 30 VDC DC rating shown for resistive loads (2) 10A DPDT, 250 VAC (2) 10A DPDT, 30 VDC DC rating shown for resistive loads (2mm) Response Time On Off Time Delay Enclosure Environmental Rating Conduit Connection 250 msec 250 msec 0-30 seconds NEMA 4X; IP65 1 NPT Maximum Remote Distance 50 ft. (15.2 m) from Sensor Ambient Temperature Range -40 to 160 o F (-40 to 71 o C) Failsafe Field-selectable Maximum Current Draw (Line Power) 24 VDC 440 ma 120 VAC 120 ma 240 VAC 60 ma Process Temperature Range Maximum Process Pressure Shipping Weight* -40 to 250 o F (-40 to 121 o C) 2000 psig (138 bar) 7 lbs. (3.2 kg) lbs. (4.8 kg) for cast iron housing + 2 lbs. (1 kg) for remote. *See page 22 for sensor shipping weights. 12/24 Registered Quality System to ISO 9001:2000

13 Model Number System 722K3-N-P6-C-PL 722 ultrasonic switch with integral housing copper-free aluminum, 24VDC power supply, with optional pump logic CS FM PL BK PK PP RG RR TT VV YY Accessories 722 K 3NP 6 C PL Model Number How to Order The 722 is comprised of two parts. The fi rst is the electronics and housing; the second is the sensor. Refer to page 19 for the sensor model number. Electrical Housing Integral (Aluminum) Integral (Cast Iron) Remote (Aluminum) Power Supply 24 VDC 120 VAC 240 VAC 1 K L R CSA Certifi ed Explosion Proof* FM Approved Explosion Proof* (except L3 housing) Pump logic (see page 16 for function and ratings) Remote electronics fl at surface mounting bracket (R housing only) (see pages 14 & 15) PK Pipe mounting kit, BK accessory required (R housing only)(see pages 14 & 15) Fiber tag with customer specifi ed tag information Gold-contact relay (6, 7, 8 power only) SS nameplate wired to the unit with customer specifi ed tag information SS nameplate permanently affi xed to housing with customer specifi ed tag information Fungicidal varnish applied to housing exterior Epoxy coating applied to housing exterior Agency Approvals Agency Safety Method Approval Model(s) FM Explosion Proof Class I, Groups B, C, D; 722K3-N-Px-FM Class II, Groups E, F, G; Class III, Division 1 Class I, Groups C, D; Class II, Groups E, F, G; Class III, Division 1 722R3-N-Px-FM CSA Explosion Proof Class I, Groups B, C, D Class II, Groups E, F, G; Class III, Division 1 Class I, Groups C, D Class II, Groups E, F, G; Class III, Division 1 722K3-N-Px-CS 722L3-N-Px-CS 722R3-N-Px-CS Registered Quality System to ISO 9001: /24

14 Housings Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certifi ed drawings for a particular model number. Dimensions are expressed as millimeter over inches (Linear = mm/in.). Housing: K1, K2 Drawing Housing: R1, R2 Drawing Process Connection *Add to Length 3/4 NPT(M) Shown 1 NPT(M) Add /2 NPT(M) 2 NPT(M) Add /24 Registered Quality System to ISO 9001:2000

15 Dimensions Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certifi ed drawings for a particular model number. Dimensions are expressed as millimeter over inches (Linear = mm/in.). Housing: R3 Drawing Housing: K3, L3 Drawing Process Connection *Add to Length 3/4 NPT(M) Shown 1 NPT(M) Add /2 NPT(M) 2 NPT(M) Add Housing: K4 Drawing Housing: R4 Drawing Registered Quality System to ISO 9001: /24

16 Pump Logic Accessory Two point ultrasonic level switches can be supplied with an on-board DPDT relay for pump control. The relay is rated 10 amp, 250 VAC; 10 amp, 30 VDC (resistive) and it can be fi eld wet to pump up (left diagram) or pump down (right diagram). Adding the pump logic (PL) accessory to the end of a model number changes level indication relays to SPDT and changes current requirements according to the table shown: Up Relay Off Relay On Relay On Relay Off Down Supply Voltage Maximum Current Draw 24 VDC 350 ma 120 VAC 120 ma 240 VAC 50 ma Time Delay When using time delay accessory OD or OF, choose a standard time delay from the chart below. Include the time delay after the model number. For example: 701K1-U-P6-C-OD OD = 60 seconds. Time Delay in Seconds (choose one) Approximate Shipping Weights Actual shipping weights may vary from charted values because of product material, confi gurations and packaging requirements. For remote electrical housing add 2 lbs. (1kg) to total weight. Ultrasonic Series Weight (lbs.) (kgs) Additional Weights 701, , lbs. (4.8 kg) for cast iron housing 16/24 Registered Quality System to ISO 9001:2000

17 Remote electronic housings are supplied for line mounting as a standard. Optional brackets are available for fl at surface or pipe mounting. Mounting Bracket Accessory Drawing The basic BK bracket can be adapted for mounting onto 1-1/2 to 2 pipe or stanchion by adding designator PK after BK. For the basic fl at surface mounting bracket, add designator BK to the end of any model number from the controls section in the front of this catalog. Linear = mm/in. Drawing Registered Quality System to ISO 9001: /24

18 Single-point Ultrasonic Sensor Model Number System 371-U-2-C-3A-RR The 371 sensor is designed for use with all signal-point ultrasonic electronic unit. 4 Process Connection Sensor Material 316SS (standard) Monel (N type sensor) Carpenter 20 (N type sensor) Hastelloy C (N type sensor) Tefl on (N type sensor) 3 Insertion Length 2 3 C A L J G 3A 4A 5A 6A 3D 3E 3F 3G 3H 3K 3L 3M 3N 3P 3/4 NPT 1 NPT 1-1/2 NPT 2 NPT 1 150# ANSI RF Flange 1-1/2 150# ANSI RF Flange 2 150# ANSI RF Flange 3 150# ANSI RF Flange 4 150# ANSI RF Flange 1 300# ANSI RF Flange 1-1/2 300# ANSI RF Flange 2 300# ANSI RF Flange 3 300# ANSI RF Flange 4 300# ANSI RF Flange Enter the required probe length, A, in inches (as a decimal, up to fi ve characters including the decimal, leading zeroes not required.) Maximum two digits after decimal point). Minimum 3 (Minimum 1.16 for Sensor U; minimum 3 for sensor with fl ange). Maximum Sensor Type 1 Probe Length in Decimal Form 5 CS AI FM FI Accessories CSA Certifi ed Explosion Proof* (U & N type sensors) CSA Certifi ed Intrinsically Safe* (U & N type sensors) FM Approved Explosion Proof* (U & N type sensors) FM Approved Intrinsically Safe* (U & N type sensors) Vertical Gap (701) Horizontal (Notch) Gap (711, 721) Viscous Gap (711, 721) 1 U N V PP RR TT Fiber tag with customer specifi ed tag information SS nameplate wired to the unit with customer specifi ed tag information SS nameplate permanently affi xed to housing with customer specifi ed tag information 371 U 2 C 3A RR Model Number 1 V type sensor requires a 3 or larger fl ange connection. 2 N types sensor with G material has a maximum length of G Sensor material is only available with 3/4 process connection. *Match sensor approvals to electronics approvals to maintain the agency listing integrity. 18/24 Registered Quality System to ISO 9001:2000

19 Dual-point Ultrasonic Sensor Model Number System 372-N-12-C3A-CS The 372 sensor in designed for use with all dual-point ultrasonic electronic units. 4 Process Connection Sensor Material Insertion Length B 316SS (standard) Monel Carpenter 20 Hastelloy C 2 3 C A L J 3A 4A 5A 6A 3D 3E 3F 3G 3H 3K 3L 3M 3N 3P 3/4 NPT 1 NPT 1-1/2 NPT 2 NPT 1 150# ANSI RF Flange 1-1/2 150# ANSI RF Flange 2 150# ANSI RF Flange 3 150# ANSI RF Flange 4 150# ANSI RF Flange 1 300# ANSI RF Flange 1-1/2 300# ANSI RF Flange 2 300# ANSI RF Flange 3 300# ANSI RF Flange 4 300# ANSI RF Flange Enter the required probe length, B in inches (as a decimal, up to fi ve characters including the decimal, leading zeroes not required.) Maximum two digits after decimal point. Minimum 3. Maximum 48. Probe Length in Decimal Form 5 CS FM Accessories CSA Certifi ed Explosion Proof* FM Approved Explosion Proof* Insertion Length A Enter the required probe length, A, in inches (as a decimal, up to fi ve characters including the decimal; leading zeros not required). Maximum two digits after decimal point. Minimum 3. Maximum Probe Length in Decimal Form PP RR TT Fiber tag with customer specifi ed tag information SS tag wired to probe with customer specifi ed tag information SS nameplate permanently affi xed to housing with customer specifi ed tag information 372 N 1 2 C 3A CS Model Number See page 22 for fl ange shipping weights. *Match sensor approvals to electronics approvals to maintain the agency listing integrity. Registered Quality System to ISO 9001: /24

20 Electronics Sensors Point Level Control 4-20 ma (P9) Certificates C1 C3 C4 Calibration Inspection Report Compliance / Conformance Horizontal Single Horizontal Dual Series 701 Vertical Tefl on, Epoxy, Viscous Certificates Hydrostatic Pressure Test C2 Note: The echosonix TM Transmitter has only one available certifi cate; C4 - Compliance/Conformance. The Point Level Control 4-20 ma (P9) is not available with C6 - Insulation Resistance Ultrasonic Switches Dimensions shown are for reference only. Contact the factory for certifi ed dimension drawings. Linear = mm/in. Type U Single Point (Threaded) Drawing Sensor Dimensions Process Connection *Add to Length 3/4 NPT(M) Shown 1 NPT(M) Add /2 NPT(M) 2 NPT(M) Add Type U Single Point (Flanged) Drawing /24 Registered Quality System to ISO 9001:2000

21 Sensor Dimensions Dimensions shown are for reference only. Contact the factory for certifi ed dimension drawings. Linear = mm/in. Process Connection *Add to Length 3/4 NPT(M) Shown 1 NPT(M) Add /2 NPT(M) 2 NPT(M) Add Type N Single Point (Threaded) Drawing Type N Single Point (Flanged) Drawing Registered Quality System to ISO 9001: /24

22 Sensor Dimensions Dimensions shown are for reference only. Contact the factory for certifi ed dimension drawings. Linear = mm/in. Type N Dual Point (Threaded) Drawing Type N Dual Point (Flanged) Drawing /24 Registered Quality System to ISO 9001:2000

23 Sensor Dimensions Dimensions shown are for reference only. Contact the factory for certifi ed dimension drawings. (Linear = mm/in.) Type V Single Point (Flanged) Drawing Sensor Style Types U & N Type V Shipping Weight 0.5 lbs. for fi rst 6 1 lb. (0.5 kg) for each additional lbs. (5.2 kg) for fi rst 6 (includes fl ange) 1 lb. (0.5 kg) for each additional 12 Flange Weight and Pressure Rating Process Connection Add to Shipping Weight lbs. kg 3D E F G 9 4 3H K L M N P Maximum Pressure Rating 275 psig (19 bar) 720 psig (50 bar) Registered Quality System to ISO 9001: /24

24 SOR offers a full line of commercial-grade process instruments. echosonix Level Transmitters Level Switches Level Temperature Switches Pressure Temperature Pressure Switches Flow Switches Flow Process Instrumentation We Deliver Quality On Time SOR Inc West 105th Street Lenexa, Kansas Phone Toll Free Fax SOR Europe, Ltd. Star Road Partridge Green, Sussex RH13 8RA, United Kingdom Phone Fax sales@soreur.co.uk SOR - China Room 903, No. 10 Building Wan Da Plaza No. 93 Jian Guo Road Chao Yang District Beijing, China Phone +86 (10) Fax +86 (10) Registered Quality System to ISO 9001:2000 (06.08) 2008 SOR Inc.

Ultrasonic Point Level Switches

Ultrasonic Point Level Switches see more at SORInc.com Request Quote Ultrasonic Point Level Switches Ultrasonic point level switches are a cost-effective solution for your applications. Installation requires mounting the sensor (threaded

More information

The Sub-Mini Hermet. OEM Pressure Switches Sub-Mini-Hermet and Omni

The Sub-Mini Hermet. OEM Pressure Switches Sub-Mini-Hermet and Omni OEM Pressure Sub-Mini-Hermet and Omni Factory Set Sub-Mini-Hermet The Sub-Mini Hermet has the ability to be externally adjusted without disconnecting electrical service or tamperproof. These field mounted

More information

Sensall Sapphire. Thermo MeasureTech ULTRASONIC POINT LEVEL SYSTEM

Sensall Sapphire. Thermo MeasureTech ULTRASONIC POINT LEVEL SYSTEM ULTRASONIC POINT LEVEL SYSTEM Introduction Compliance with growing government regulations mandates tighter level controls with advanced diagnostics to avoid releases, overspills and costly environmental

More information

Electromechanical Temperature Switches

Electromechanical Temperature Switches The SOR Electromechanical Temperature Switch utilizes a vapor-pressure thermal system. Fluid vapor pressure changes predictably according the influence of temperature on the sensing bulb. Process temperature

More information

Sapphire ULTRASONIC POINT LEVEL SYSTEM

Sapphire ULTRASONIC POINT LEVEL SYSTEM ULTRASONIC POINT LEVEL SYSTEM Introduction Compliance with growing government regulations mandates tighter level controls with advanced diagnostics to avoid releases, overspills and costly environmental

More information

Electromechanical Temperature Switches

Electromechanical Temperature Switches The SOR Electromechanical Temperature Switch utilizes a vapor-pressure thermal system. Fluid vapor pressure changes predictably according the influence of temperature on the sensing bulb. Process temperature

More information

Electronic Flow Switches

Electronic Flow Switches Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor

More information

Installation and Operating Instructions

Installation and Operating Instructions The Leader of RF and Sonic Level For Assistance Call 1-800-527-6297 Outside North America 1-215-674-1234 Installation and Operating Instructions Series 504-1200 Ultrasonic VeriGAP Switch using 404-1200

More information

E C H O T E L C O N T A C T U L T R A S O U N D

E C H O T E L C O N T A C T U L T R A S O U N D E C H O T E L C O N T A C T U L T R A S O U N D Contact Ultrasonic Level Sensing FROM Ultrasound technology was developed during the amplifier becomes as oscillator causing a relay WWII under the acronym

More information

ABB MEASUREMENT & ANALY TICS DATA SHEET. RS85 Vibrating fork level switch

ABB MEASUREMENT & ANALY TICS DATA SHEET. RS85 Vibrating fork level switch ABB MEASUREMENT & ANALY TICS DATA SHEET RS85 Vibrating fork level switch 2 RS 8 5 VI BR ATI N G FOR KL EVEL SW ITC H DS/RS8 5-E N RE V. S Measurement made easy Multi option liquid level switch K TEK Level

More information

www.severntrentservices.com CAPITAL CONTROLS Series 70CV3000 Chloromatic TM Intelligent Gas Flow Control Valve The Series 70CV3000 Chloromatic TM Intelligent Gas Flow Control Valve is designed to control

More information

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

Brooks MT3600 Series Metal Tube Variable Area Flowmeters Data Sheet Flanged, NPT or socket-welded connections 10% full scale accuracy Disassembly for cleaning without removal from the process line Standard direct reading, detachable scales Permanent magnetic

More information

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

MSM400 Ultrasonic Suspended Solids Monitoring and Control System Product Data Sheet MSM400 Ultrasonic Suspended Solids Monitoring and Control System Continuous sludge discharge monitor for up to 50% suspended solid The MSM400 system contains a control unit and either

More information

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel PROTECTOWIRE FireSystems Features Easily expandable Two supervised audible circuits Lamp and system trouble circuit test Ground fault detection Initiating device circuit (IDC) alarm test Monitors up to

More information

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen. It uses a high performance

More information

ULTRA-SAFE Explosion-proof Duct Heaters

ULTRA-SAFE Explosion-proof Duct Heaters Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer

More information

Model D12-IR. Digital Gas Transmitter...

Model D12-IR. Digital Gas Transmitter... Model D12-IR Digital Gas Transmitter... ATI s Series D12 gas transmitter line now includes a versatile Infrared system that can be configured for LEL or select toxic gases. The D12-IR utilizes a compact

More information

1510 Side Mounted Level Switch

1510 Side Mounted Level Switch 1510 Side Mounted Level Switch General Instructions The SOR 1510 Level Switch mounts into the side of a vessel. Electric switching action is provided by the float moving a magnet into the field of a hermetically

More information

ECHOTEL 961/962. Ultrasonic level switches. Worldwide level and flow solutions DESCRIPTION. Loop or line powered FEATURES AGENCY APPROVALS

ECHOTEL 961/962. Ultrasonic level switches. Worldwide level and flow solutions DESCRIPTION. Loop or line powered FEATURES AGENCY APPROVALS ECHOTEL 961/962 Ultrasonic level switches DESCRIPTION The Echotel 961/962 series utilizes pulse signal technology to detect high or low level alarm(s) in a broad range of viscous to light liquids. Pulsed

More information

ULTRA-SAFE Explosion-proof Duct Heaters

ULTRA-SAFE Explosion-proof Duct Heaters Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer

More information

Commercial and Light Industrial Fire Alarm Control Panel

Commercial and Light Industrial Fire Alarm Control Panel FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel Features Easily expandable. All new plug-in board design Two supervised audible circuits Lamp and system trouble circuit test Ground

More information

TABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation 4 Detection Through Walls 4 Sensing Beam Shape 4 Installation

TABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation 4 Detection Through Walls 4 Sensing Beam Shape 4 Installation DETECT 1000 DOPPLER DETECTION INSTALLATION AND OPERATING INSTRUCTIONS READ THOROUGHLY BEFORE INSTALLING EQUIPMENT TABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation

More information

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion

More information

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Fixed Gas Detector Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Including e-box for increased safety wiring The Dräger

More information

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen It uses a high performance

More information

805QS Pressure Switch-Transmitter

805QS Pressure Switch-Transmitter 805QS Pressure Switch-Transmitter These instructions provide information for installation, process connection, n, electrical connection, operation and maintenance of the 805QS pressure switch-transmitter.

More information

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly DREXELBROOK A Leader In Level Measurement Solutions USonic-R Series Ultrasonic Level Measurement System User Friendly Set the measurement range directly in inches, feet, millimeters, centimeters, or meters

More information

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67 Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67 Part #: EPSLED-80 Page: 1 Made in Texas The EPSLED-80 Explosion Proof LED Strobe Light from Larson Electronics is UL

More information

Sapphire. Ultrasonic Point Level System User Guide P/N Part of Thermo Fisher Scientific. Revision C

Sapphire. Ultrasonic Point Level System User Guide P/N Part of Thermo Fisher Scientific. Revision C Sapphire Ultrasonic Point Level System User Guide P/N 900-000068 Revision C Part of Thermo Fisher Scientific Sapphire Ultrasonic Point Level System User Guide P/N 900-000068 Revision C 1992 Thermo Fisher

More information

CLARITY II TURBIDIMETER

CLARITY II TURBIDIMETER Product Data Sheet PDS 71-T1055/rev.J January 2006 Model T1055 CLARITY II TURBIDIMETER COMPLETE SYSTEM includes single or dual input analyzer, sensor(s), and debubbler assembly CHOOSE U.S. EPA METHOD 180.1

More information

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion

More information

Temperature Switches. Request Quote

Temperature Switches. Request Quote SEE MORE AT SORInc.com Request Quote Temperature The SOR temperature switch utilizes a vapor-pressure thermal system. Fluid vapor pressure changes predictably according the influence of temperature on

More information

Mobrey ultrasonic Liquid level detection systems

Mobrey ultrasonic Liquid level detection systems Product data sheet IP201, Rev AA February 2009 Level Mobrey ultrasonic Liquid level detection systems Description Ultrasonic liquid level switches are used in industrial processes, to detect high or low

More information

Capital Controls SERIES 70CV3000 CHLOROMATIC VALVE

Capital Controls SERIES 70CV3000 CHLOROMATIC VALVE Capital Controls SERIES 70CV3000 CHLOROMATIC VALVE Integrated Gas Control Valve with Integral Controller The Series 70CV3000 Chloromatic Intelligent Gas Flow Control Valve is designed to control chemical

More information

RF Admittance Technology FACTS

RF Admittance Technology FACTS RF Admittance Technology FACTS Each year RF Admittance is the most purchased technology offered in electronic point level products Versatile technology, well proven in a wide range of applications in solid,

More information

High Pressure Conductivity Monitor

High Pressure Conductivity Monitor Product Data Sheet PDS 71-EDS880/1/rev.A August 2006 Model EDS880/1 High Pressure Conductivity Monitor COMPLETE SYSTEM FOR THE DETERMINATION OF CONDUCTIVITY IN HIGH PRESSURE SYSTEMS SENSOR INSTALLS DIRECTLY

More information

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery Thermo Scientific Ramsey TM Series 60-200 Sensing Speed Conditions on Rotating Shafts and Machinery The Thermo Scientific Ramsey Series 60-200 monitors under-speed, overspeed and zero-speed conditions

More information

AMERITROL, INC. INSTALLATION OPERATION MANUAL AND WIRING DIAGRAM LX SERIES LIQUID LEVEL SWITCH WITH ADDITIONAL TEMPERATURE TRANSMITTER

AMERITROL, INC. INSTALLATION OPERATION MANUAL AND WIRING DIAGRAM LX SERIES LIQUID LEVEL SWITCH WITH ADDITIONAL TEMPERATURE TRANSMITTER AMERITROL, INC. INSTALLATION OPERATION MANUAL AND WIRING DIAGRAM LX SERIES LIQUID LEVEL SWITCH WITH ADDITIONAL TEMPERATURE TRANSMITTER Manual Number: LXTT-SPDT-2114-1-A 1185L Park Center Dr. Vista CA 92081

More information

Using the DewTrak II Dew Point/ Humidity Transmitter

Using the DewTrak II Dew Point/ Humidity Transmitter APPLICATION NOTE 2016_FEB2 DT Rev 10 Using the DewTrak II Dew Point/ Humidity Transmitter The Model DewTrak ll Dew Point/Humidity Transmitter is a compact, cost effective, optical chilled mirror hygrometer.

More information

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 5700 IR Detection of flammable gases and vapours Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive

More information

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger Polytron 5720 IR Detection of carbon dioxide Dräger Polytron 5720 IR Detection of carbon dioxide The Dräger Polytron 5720 IR is a cost effective explosion proof transmitter for the detection of carbon dioxide in percent volume or ppm It uses a high

More information

Glass Tube Variable Area Flowmeter

Glass Tube Variable Area Flowmeter GT 1000 Series Models 1020, 1024, 1026, 1027 Design Specifications DS-GT 1000 April, 1997 (Supersedes issue dated December, 1996) Glass Tube Variable Area Flowmeter Wide choice of application-specific

More information

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery Ramsey Series 60-200 Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery Ramsey Series 60-200 Motion Monitoring Systems offer versatile and reliable packages

More information

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev. STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.1 Introduction Honeywell s STT 3000 family of microprocessor based smart

More information

DTM Distributed Transmitter-Monitor

DTM Distributed Transmitter-Monitor DTM Distributed Transmitter-Monitor DTM10 Proximity Distributed Transmitter-Monitor (Shaft Vibration, Thrust Position and Speed) The DTM10 distributed vibration transmitter-monitor is ideal for monitoring

More information

Level Measurement Continuous level measurement Ultrasonic transmitters

Level Measurement Continuous level measurement Ultrasonic transmitters Overview Configuration is a short-range integrated ultrasonic level transmitter. This intrinsically safe, 2 wire, 4 to 20 ma loop powered transmitter is ideal for liquids, slurries, and bulk materials

More information

Rosemount 2090P Pulp and Paper Pressure Transmitter

Rosemount 2090P Pulp and Paper Pressure Transmitter Product Data Sheet Rosemount 2090P Pulp and Paper Pressure Transmitter Rosemount 2090P 1-inch flush mount compatible with a PMC process connection, or 1 1 /2-inch threaded mounting connection Absolute

More information

Pump-Down Controller MODEL 4052

Pump-Down Controller MODEL 4052 Pump-Down Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4052 Pump-Down

More information

VIBRATION TRANSMITTER MODEL 140T INSTALLATION The mounting orientation can be in any position. This position should be in an area for the best vibrati

VIBRATION TRANSMITTER MODEL 140T INSTALLATION The mounting orientation can be in any position. This position should be in an area for the best vibrati VIBRATION TRANSMITTER MODEL 140T A lowcost, yet highly accurate and rugged vibration transmitter, the Model 140T is ideal for use with all machines, even those which previously may have been considered

More information

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger Polytron 8200 CAT Detection of flammable gases and vapors Dräger Polytron 8200 CAT Detection of flammable gases and vapors The Dräger Polytron 8200 CAT is an advanced explosion proof transmitter for the detection of flammable gases in the lower explosion limit

More information

Model Q45P/R. ph/orp Monitor...

Model Q45P/R. ph/orp Monitor... Model Q45P/R ph/orp Monitor... Sensor Mounting Configurations The Differential Difference ORP Monitor ATI's versatile Q45P/R ph/orp system is designed for use in all industrial and municipal applications.

More information

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009 STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009 Introduction Honeywell s STT 3000 family of microprocessor based transmitters covers the full

More information

Pump-Up Controller MODEL 4062

Pump-Up Controller MODEL 4062 Pump-Up Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4062 Pump-Up

More information

Process Instrumentation. Product Guide. Registered Quality System to ISO 9001

Process Instrumentation. Product Guide. Registered Quality System to ISO 9001 Process Instrumentation Product Guide Registered Quality System to ISO 9001 SORis committed to and understands the demanding requirements of the process industry. We design, develop and manufacture the

More information

Model Q45P/R. ph/orp Monitor...

Model Q45P/R. ph/orp Monitor... Model Q45P/R ph/orp Monitor... Sensor Mounting Configurations The Differential Difference ORP Monitor ATI's versatile Q45P/R ph/orp system is designed for use in all industrial and municipal applications.

More information

Process Protection. MFA 4P Motion Failure Alarm

Process Protection. MFA 4P Motion Failure Alarm Process Protection MFA 4P Motion Failure Alarm Part 1. General 1.1 Scope A. This section describes the requirements for a motion alarming system. B. Under this item, the contractor shall furnish and install

More information

Technical Specification VFD

Technical Specification VFD Technical Specification - 3-6 VFD Pilot valve enclosures suitable for use in hazardous certified environments. These enclosures are designed and tested to contain both flame and the ignition of dust and

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

Dual Input ph/orp Analyzer

Dual Input ph/orp Analyzer Instruction Sheet PN 51A-1055pH/rev.I February 2006 Model 1055 SOLU COMP II Dual Input ph/orp Analyzer Model Option 1055-22-32 For additional information, please refer to the Instruction Manuals CD shipped

More information

Ramsey Motion Monitoring Systems

Ramsey Motion Monitoring Systems Ramsey Motion Monitoring Systems 60-200 Motion Monitoring Accurate Sensing of Underspeed, Overspeed and Zero Speed Conditions on Rotating Shafts and Machinery The Ramsey Series 60-200 Motion Monitoring

More information

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS GENERAL INDEECO Industrial Control Panels are designed to provide years of trouble free operation if properly

More information

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage. LC-100 Tank Level Indicator Engineered specifically for the Offshore & Marine markets, LevelCom TLI s have a proven record of success in 20 years of use in harsh environments. The LC-100 microprocessor

More information

Description. Applications

Description. Applications CVEP PDS CVEP Convection for Hazardous Heater For Locations Hazardous Locations Convection Heater 1.8 to 9.0kW (T-2A) 280 C (536 F) 1.6 to 4.0kW (T-3A) 180 C (356 F) 1.8 to 9.0kW (T-2) 1.8 300 C to 9.0kW

More information

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0) Data Sheet 220 LEVEL MONITOR Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com Model 220 Powered by 4-20mA loop Non-linear tank correction Four level alarms Level bar graph display

More information

Page. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller

Page. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller Order from: C A Briggs Company 622 Mary Street; Suite 101; Warminster, PA 18974 Phone: 267-673-8117-800-352-6265; Fax: 267-673-8118 Sales@cabriggs.com - www.cabriggs.com Page 1-2 Sepra-Lite Integral Optic

More information

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Polytron 5720 IR Toxic Gas Detection Dräger Polytron 5720 IR Toxic Gas Detection The Dräger Polytron 5720 IR is a cost-effective explosion proof transmitter for the detection of carbon dioxide in volume percentage or ppm It uses a high-performance

More information

Product Guide Registered Quality System to ISO 9001:2008

Product Guide Registered Quality System to ISO 9001:2008 Product Guide Registered Quality System to ISO 9001:2008 SOR is on your side. We understand the demanding requirements of the process instrumentation industry and the harsh environments that our products

More information

SPECIFICATIONS - DETAILED PROVISIONS Section Magnetic Flowmeters C O N T E N T S

SPECIFICATIONS - DETAILED PROVISIONS Section Magnetic Flowmeters C O N T E N T S Revised 04/13/16 SPECIFICATIONS - DETAILED PROVISIONS Section 17210 - Magnetic Flowmeters C O N T E N T S PART 1 - GENERAL... 1 1.01 GENERAL REQUIREMENTS... 1 1.02 PROJECT SPECIFIC REQUIREMENTS... 1 1.03

More information

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 8100 EC Detection of toxic gases and vapors Dräger Polytron 8100 EC Detection of toxic gases and vapors The Polytron 8100 EC is Dräger s top of the line explosion proof transmitter for the detection of toxic gases or oxygen It uses a high performance

More information

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 2090F Hygienic Pressure Transmitter Hygienic Pressure Transmitter Conforms to 3-A Sanitary s Features CIP/SIP service for process temperatures up to 284 F (140 C) Absolute or gage pressure ranges from 0-1.5 to 0-300 psi Mounts with either

More information

Rosemount 2100 Series

Rosemount 2100 Series Rosemount 2100 Series Vibrating Fork Liquid Level Switches Level switches for demanding applications Reliable performance... Rosemount 2100 series vibrating fork level switches are suitable for virtually

More information

MODEL APT 3700N. Smart Pressure Transmitter For Nuclear Service. Duon System Co., Ltd. for Differential / Gauge / Absolute Pressure Measurement

MODEL APT 3700N. Smart Pressure Transmitter For Nuclear Service. Duon System Co., Ltd. for Differential / Gauge / Absolute Pressure Measurement DOC. NO. : 3700N-E01I For Nuclear Service for Differential / Gauge / Absolute Pressure Measurement MODEL APT 3700N (GASAN-DONG), 232, BEOTKKOT-RO GUMCHON-GU SEOUL KOREA Tel : +82-2-860-7900 Fax : +82-2-860-7997

More information

Instruction Manual Model A

Instruction Manual Model A 706 Bostwick Avenue, Bridgeport, CT 06605 TEL: 203-368-6751 FAX: 203-368-3747 1-800-566-6822 www.devarinc.com Instruction Manual Model 18-232A LOOP POWERED ALARM MANUAL NO. 990029 MODEL 18-232A LOOP POWERED

More information

Model 4001 Series Single Channel Controller

Model 4001 Series Single Channel Controller Model 4001 Series Single Channel Controller Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 (800) 727-4377 (408) 262-9042 - Fax E-Mail: sales@sierramonitor.com Web site:

More information

Installation, operation & service manual. AlarmScout 961/962 line powered

Installation, operation & service manual. AlarmScout 961/962 line powered AlarmScout 961/962 (line powered) Installation, & service manual AlarmScout 961/962 line powered @@ UNPACKING Unpack the instrument carefully. Make sure all components have been removed from the foam protection.

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor... Improve Performance and Reduce Maintenance Costs Model Q45D Dissolved Oxygen Monitor... Why Throw Away Money? Why Throw Away Money? ATI s Model Q45D Dissolved Oxygen monitor is designed to provide reliable

More information

M-Switch Float Operated Liquid Level Switch

M-Switch Float Operated Liquid Level Switch Product Data Sheet M-Switch Float Operated Liquid Level Switch Reliably detects the liquid level to give a voltage free contact operation for alarm signalling or as part of a pump control system Small

More information

Process Instrumentation. Product Guide

Process Instrumentation. Product Guide Process Instrumentation Product Guide Registered Quality System to ISO 9001:2000 SOR is on your side. We understand the demanding requirements of the process instrumentation industry and the harsh environments

More information

Explosion Proof Push Button Momentary Switch - C1D1, C2D1 - Adjustable Timer - 10 sec-170 Minutes

Explosion Proof Push Button Momentary Switch - C1D1, C2D1 - Adjustable Timer - 10 sec-170 Minutes Explosion Proof Push Button Momentary Switch - C1D1, C2D1 - Adjustable Timer - 10 sec-170 Minutes Part #: EPS-PB10-MS-AT-V3 Made in the USA The Larson Electronics EPS-PB10-MS-AT-V2 Explosion Proof Push

More information

STT 3000 Series STT250 SMART TEMPERATURE TRANSMITTER Models STT25H, STT25M, STT25D

STT 3000 Series STT250 SMART TEMPERATURE TRANSMITTER Models STT25H, STT25M, STT25D STT 3000 Series STT250 SMART TEMPERATURE TRANSMITTER Models STT25H, STT25M, STT25D EN0I-6031 12/00 PRODUCT SPECIFICATION SHEET OVERVIEW Honeywell s STT 3000 family of microprocessor based smart temperature

More information

WH EN IGH T T C LO SED

WH EN IGH T T C LO SED AR EA kajdfkjl; lkjdflkjal; ldkfj;alk alskjdf ;lsdkf 7079 ph/orp Transmitter 70-82-03-08 1/97 Page 1 of 5 Specification Overview The 7079 ph/orp Transmitter is designed for chemical process industry applications

More information

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger Polytron 8200 Stationary gas detector (CatEx) Dräger Polytron 8200 Stationary gas detector (CatEx) Quick, reliable and cost-effective detection of combustible gases and vapours in the ambient air: the microprocessor-based transmitter is the result

More information

MODEL 4100-LEV. Level Monitor. User Manual

MODEL 4100-LEV. Level Monitor. User Manual MODEL 4100-LEV Level Monitor User Manual Technical Support Continental North America Toll Free 1-(800) 387-9487 Ph: +1 (905) 829-2418 Fx: +1 (905) 829-4701 A Product of Arjay Engineering Ltd. Oakville,

More information

Dual Input Toroidal Analyzer

Dual Input Toroidal Analyzer Instruction Sheet PN 51A-1055T/rev.H February 2006 Model 1055 SOLU COMP II Dual Input Toroidal Analyzer Model Option 1055-21-31 For additional information, please refer to the Instruction Manuals CD shipped

More information

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products: Model 2102 Gas Alarm Panel APPLICABILITY & EFFECTIVITY This manual provides instructions for the following Sierra Monitor products: Model Description 2102-00 Alarm Panel 2 Channel 2102-01 Alarm Panel 2

More information

Dual Input ph/conductivity Analyzer

Dual Input ph/conductivity Analyzer Instruction Sheet PN 51A-1055pHC/rev.I January 2006 Model 1055 SOLU COMP II Dual Input ph/conductivity Analyzer Model Option 1055-22-30 For additional information, please refer to the Instruction Manuals

More information

UW Purchase Specification Section Steam Condensate or Hot Water Meter Page 1 of 9

UW Purchase Specification Section Steam Condensate or Hot Water Meter Page 1 of 9 Page 1 of 9 PART 1 GENERAL 1.02 DESCRIPTION A. Purpose 1. This section covers steam condensate meters, steam condensate sub-meters and hot water sub-meters for use in the Owner's steam systems. 1.03 QUALIFICATIONS

More information

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters Product Data Sheet Non-contacting measurement with no moving parts Fast and simple to install and configure Continuous measurement of level, contents (volume), or open channel flow MCERTS certified version

More information

Dräger Polytron 8310 Stationary gas detector (DSIR)

Dräger Polytron 8310 Stationary gas detector (DSIR) Stationary gas detector (DSIR) SIMPLE INSTRUMENT MANAGEMENT POISON-RESISTANT AND FAIL-SAFE THANKS TO DIGITAL COMMUNICATION The DrägerSensor IR offers several benefits: technological advantages such as

More information

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 8100 EC Detection of toxic gases and oxygen Dräger Polytron 8100 EC Detection of toxic gases and oxygen The Polytron 8100 EC is Dräger s top of the line explosion-proof transmitter for the detection of toxic gases or oxygen It uses a high performance

More information

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer Model 6650SP Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer 6650SP - OVERVIEW The Model 6650SP is the next generation in-water Analyzer. The 6650SP incorporates the most advanced, state-of-the-art

More information

Rosemount 3051CFP Integral Orifice Flowmeter

Rosemount 3051CFP Integral Orifice Flowmeter December 2013 Rosemount 3051 Rosemount 3051CFP Integral Orifice Flowmeter See Specifications on page 47 and options for more details on each configuration. Rosemount 3051CFP Integral Orifice Flowmeters

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296

More information

EVLPF Series Compact Fluorescent

EVLPF Series Compact Fluorescent EVLPF Series Low Profile Hazard Gard Luminaires Cl. I, Div. 1, Groups B (GB Suffix), C, D Cl. I, Zone 1, Groups IIB + H2 (GB Suffix), IIB, IIA Cl. II, Div. 1, Groups E, F, G Class III, Simultaneous Presence

More information

Analog Room Pressure Monitor RPC Series

Analog Room Pressure Monitor RPC Series Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the

More information

Instruction Manual. Princo Model L3522. Point Level Controllers with LEVEL SENTRY. Rev 2, June 2013

Instruction Manual. Princo Model L3522. Point Level Controllers with LEVEL SENTRY. Rev 2, June 2013 Instrumentation designed with the user in mind Instruction Manual Princo Model L3522 Point Level Controllers with LEVEL SENTRY Rev 2, June 2013 PRINCO INSTRUMENTS INC., 1020 INDUSTRIAL BLVD., SOUTHAMPTON,

More information

Ar-Mite TM Low Flow Armored Flowmeter

Ar-Mite TM Low Flow Armored Flowmeter Data Sheet Brooks Ar-Mite TM MT 3750C Ar-Mite TM Low Flow Armored Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter with Transmitter or Inductive Alarm

More information

INSTRUCTIONS FOR THE LCR10 TEN INCH CIRCULAR CHART RECORDER

INSTRUCTIONS FOR THE LCR10 TEN INCH CIRCULAR CHART RECORDER INSTRUCTIONS FOR THE LCR10 TEN INCH CIRCULAR CHART RECORDER LOVE LOVE CONTROLS a Division of Dwyer Instruments, Incorporated PO Box 338 Michigan City, IN 46361-0338 (800) 828-4588 (219) 879-8000 FAX (219)

More information

Instrumentation and Controls Group

Instrumentation and Controls Group Instrumentation and Controls Group Jerguson Gage and Valve is the leading supplier of level gaging products, offering the world s largest selection of liquid level gage glasses, magnetic gages, and accessories.

More information