Temporary wireless battery operated fire system from Channel Safety Systems
|
|
- Theodore Barker
- 5 years ago
- Views:
Transcription
1 Temporary wireless battery operated fire system from Channel Safety Systems CHANNEL SAFETY SYSTEMS t: Petersfield Business Park f: Bedford Road Petersfield Hampshire e: GU32 3QA w: INSTRUCTI MANUAL - Issue 1-02/ INSTRUCTI MANUAL
2 INTERFACE PRESENTATI & FEATURES The radio link alarm interface module allows to transmit a fire alarm from radio linked alarm devices (MCP, stand alone alarm and smoke detector) to an anti-intrusion control panel, a remote transmitter, a sounder, a beacon, etc. Operating principle When a radio linked device (MCP, stand alone alarm or smoke detector) is in alarm, it sends the information to the radio link alarm interface module which changes its state (change-over contact), thus transmitting the alarm information to the intrusion control panel (or else). lid fastening screws Alarm LED Radio LED switch Features lid BR1 BR2 BR C R T External supply : 12 V (supplied by a control panel for example) Standby consumption: V Alarm consumption : V Indoor environment Operating temperature : -10 C to +50 C Housing Dimensions : H 83 mm x l 83 mm x D 46 mm Hole pitch : 40 mm Colour : red Interconnection Capacity Number of smoke detectors and stand alone alarm per radio link alarm Interface module : non restrictive Up to 10 radio link alarm interface module within a system Radio range in free-field condition : 100 meters radio link interface module fastening screws radio electronic board housing white plastic cap cable gland Radio relay card Wiring BR1 BR2 BR C R T Supply 12Vdc Local Alarm input (contact No) Relay contact INSTRUCTI MANUAL - Issue 1-02/2014 2
3 CNECTI Follow the steps to connect the radio link interface module to a smoke detector or a stand alone alarm STEPS ACTIS SOUND SIGNALS DESCRIPTIS 1 Power up the radio link interface module (slave). 2 Press for 5 seconds the configuration key on the slave element. 3 beeps The configuration is taken into account. The slave element sends a message to be associated to the existing group. 3 Press the test key of a smoke detector or the validation key of a stand alone alarm. Long beep The radio link interface module is now connected to the system. It sets to setting optimization mode. 4 Move away to the place chosen for the radio link interface module and check the radio link quality. > See the table «checking the radio link quality» below. 5 Mount the slave element on the chosen location. 1 to 5 beeps sequences in steps of few seconds. Checking the radio link quality. 6 Press the configuration key of the slave element. 4 beeps Exit configuration mode. 4 beeps Exit setting optimization mode. The system is now operational. Cancel the connection with a smoke detector or a stand alone alarm While in step 2, press for 10 seconds the configuration key (instead of 5 seconds) (see step 2 above). 4 long beeps will be heard indicating that the connection is cancelled. Checking radio link quality When the slave element is in setting optimization mode, 1 to 5 beeps can be heard in steps of few seconds. Check the radio link quality according to the number of beeps. Number of beeps Radio link quality NOT RECOMMENDED Risk of system failure Recommended installation INSTRUCTI MANUAL - Issue 1-02/2014 3
4 SWITCH CFIGURATI Default setting: Switch 1 1 Auxiliary input closing 1 Auxiliary input opening Switch «Type 4» alarm > sound on the stand alone alarms, no alarm on the smoke detector «smoke detector» alarm > intermittent sound on the stand alone alarms and activated smoke detector Switch 3 3 No activation of the alarm relay when receiving a smoke detector alarm. 3 Activation of the alarm relay when receveing smoke detector alarm messages. Switch No activation of the alarm relay when receiving a stand alone or manual call point alarm. Activation of the alarm relay when receveing stand alone alarm or manual call point alarm messages. INSTRUCTI MANUAL - Issue 1-02/2014 4
5 USE Test Regularly perform this test on all the connected smoke detectors. This test can t be carried out on the connected manual call points or stand alone alarms. 1. One smoke detector test The one smoke detector TEST function allows to check at any time the radio link quality between one smoke detector and the radio link alarm interface module. Press the TEST key of a connected smoke detector. The TEST signal is sent to the interface module (for 5 minutes). Test Signal Note For 1 minute Beeps + red blinking indicator The number of beeps and blinking correspond to the radio link quality of the last received signal. Then for 4 minutes Red blinking indicator To stop the TEST signal before the end of the test, press the interface module key. 2. All smoke detectors test The all smoke detectors TEST function allows to check at any time the radio link quality between all the connected smoke detectors and the radio link alarm interface module. Press the interface module key (short press). Test is activated for all the connected smoke detectors. A sound signal indicates that the radio signal is being sent. Note : this function is inhibited in case of alarm. Alarm signal The interface module receives alarm information from connected smoke detectors, manual call points and stand alone alarms. When an alarm information is sent, the interface module red indicator is steady on. 20 seconds after the original alarm has disappeared, the interface module is automatically reset. INSTRUCTI MANUAL - Issue 1-02/2014 5
6 VISUAL AND SOUND IDENTIFICATI Visual identification Meaning Note Blue indicator radio activity - Red indicator steady on alarm signal received - blinking test signal received the number of blinking correspond to the radio link quality of the last received signal. Sound identification Meaning Note 1 to 5 beeps sequences for 1 minute test signal received the number of beeps correspond to the radio link quality of the last received signal Sequences from 1 to 5 beeps every few seconds connection in process INSTRUCTI MANUAL - Issue 1-02/2014 6
7 ENVIRMENTAL PROTECTI 2002/96/EC (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted munici pal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. This product complies to the RoHS 202/95/EC relating to the restriction of the use of certain hazardous substances in electrical and electronical equipment since July 1st, 2006 INSTRUCTI MANUAL - Issue 1-02/2014 7
8 t: Petersfield Business Park f: Bedford Road Petersfield Hampshire e: GU32 3QA w: INSTRUCTI MANUAL
Temporary wireless battery operated fire system from Channel Safety Systems
Temporary wireless battery operated fire system from Channel Safety Systems CHANNEL SAFETY SYSTEMS t: 0845 884 7000 Petersfield Business Park f: 0845 884 6000 Bedford Road Petersfield Hampshire e: sales@channelsafety.co.uk
More informationsetting up your wireless system P300W, C300W, D300W and wireless interface Standards NFS NFS EN 54-11
setting up your wireless system P300W, C300W, D300W and wireless interface Standards NFS 61 936 NFS 32001 EN 54-11 Megalarm wireless system General points The Megalarm mini wireless fire alarm system is
More informationATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet
ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet EN 1 2 1 3 2 4 1 5 12V 6 2 0V D+ D- CON3 7 CON1 ON 3 1 2 3 4 1234 8 3 4 1 0 ON 1 2 3 4 METAL METAL Address 1 1 0 ON 1 2 3 4 Address 2 2011
More informationKFP-CF Series Operation Manual
KFP-CF Series Operation Manual P/N 501-415103-2-31 REV 03.10 ISS 13NOV13 Copyright Trademarks and patents Manufacturer Version Certification European Union directives Contact information 2013 UTC Fire
More informationCU-IQ MANUAL 1. DESCRIPTION Radio Control Panel CU-IQ
1. DESCRIPTI CU-IQ MANUAL The small control panel CU-IQ is one component of the new ICAS IQ wireless system. IQ System is an intelligent radio system, which works at 868 MHz frequency band. The IQ System
More informationSMOKE User Manual. NE v2.0
SMOKE User Manual NE41 06004-02 v2.0 1 2 3 Contents in an SMOKE kit The list below shows the included parts in the package. If any part is missing or is defect, please kontakt your reseller or distributor.
More informationSmoke Detector and Siren. Manual
Smoke Detector and Siren Manual 004001 Smoke Detector and Siren Manual Quick Start... 2 Product Description... 2 Installation Guidelines... 3 Behavior within the Z-Wave Network... 3 Operating the Device...
More informationSPECIAL CODES AUXILIARY CODES SYSTEM NOTES
Installing / Service Company Monitoring Station SPECIAL CODES Master Code Duress Code AUXILIARY CODES "Quick Arm" "Chime" 08 02 09 03 10 04 11 05 12 06 13 07 14 SYSTEM NOTES Exit Delay Time Entry Delay
More information80 CHANNELS WIRELESS RECEIVER WITH LCD DISPLAY M1.1.1-Hx.x-F1.1-ENG [AN] [SPV] MADE IN ITALY INSTALLATION AND USE MANUAL
RX808-LCD 80 CHANNELS WIRELESS RECEIVER WITH LCD DISPLAY 14.12-M1.1.1-Hx.x-F1.1-ENG [AN] [SPV] MADE IN ITALY INSTALLATION AND USE MANUAL WARNINGS Installation: This device must be installed only by qualified
More informationRef. 1067/024 Ref. 1067/032A Ref. 1067/052A
DS1067-062C Mod. 1067 LBT20063 REMOTE CONTROLLABLE ALARM CONTROL PANELS Ref. 1067/024 Ref. 1067/032A Ref. 1067/052A USER MANUAL TABLE OF CONTENTS INTRODUCTION... 6 1 CONTROL DEVICES... 7 1.1 1067/022 keypad
More informationCondominium Security Management System
User Access Codes The CONDOPLEX series panels can be programmed with nine (9) different user codes and one (1) duress code. User codes are normally used for arming and disarming the panel. The duress code
More informationAnalogue addressable devices
Apollo XP95 Analogue addressable devices from Channel Safety Systems Apollo XP95 Analogue addressable devices The XP95 range of analogue addressable fire detectors is advanced in design, improved in performance
More informationSPECIAL CODES AUXILIARY CODES SYSTEM NOTES
Installing/Service Company For Service Call SPECIAL CODES Master Code Duress Code AUXILIARY CODES "Quick Arm" " Chime" 08 02 09 03 10 04 11 05 12 06 13 07 14 SYSTEM NOTES Exit Delay Time Entry Delay Time
More informationRANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL
RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION... 2 STANDARD AND OPTIONAL PARTS LIST... 2 PARTS DIAGRAM... 3 TERMINAL DRAWING AND SPECIAL NOTES...
More informationDYGIZONE GJD910 Lighting Controller & Enunciator
DYGIZONE GJD910 Lighting Controller & Enunciator MASTER WIRING IDENTIFICATION Power up to the DygiZone and you will see: All the LED s (red,yellow,green and blue buttons) will flash All the LCD icons will
More informationCONTENTS Installation Precautions... 1 Chapter 1 Product Introduction... 2 Chapter 2 Technical Specifications... 3
CONTENTS Installation Precautions... 1 Chapter 1 Product Introduction... 2 Chapter 2 Technical Specifications... 3 2.1 Electrical Specifications... 3 2.2 Communication Loop Parameters... 3 2.3 Dimensions...
More informationControl Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2
Architectural & Engineering Specifications Control Panel 1.0 GENERAL... 2 1.1 SCOPE OF WORK... 2 1.1.1 Introduction... 2 1.2 GENERAL CONDITIONS... 2 1.2.1 After-Sales Support... 2 1.2.2 Quality assurance...
More informationAdvisor Advanced User Guide
Advisor Advanced User Guide P/N 1068996 (EN) REV G ISS 28AUG15 Copyright Trademarks and patents Manufacturer Version Certification 2015 UTC Fire & Security Americas Corporation, Inc. All rights reserved.
More informationA1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor
A1UL PERS Personal Emergency Response System TABLE OF CONTENTS 1. READ THIS FIRST... 1 2. SYSTEM OVERVIEW.. 1 3. COMPONENTS 2 4. UNIT OPERATION! Standby Mode.. 3! Emergency Activation. 3! Answering Incoming
More informationFEC403EN Installation Manual
FEC403EN Installation Manual P/N 10-4101-501-2FC1-01 ISS 22JAN15 Copyright Trademarks and patents Manufacturer 2015 UTC Fire & Security. All rights reserved. The FEC403EN name and logo are trademarks of
More information1X-F Series Installation Manual
1X-F Series Installation Manual P/N 501-415003-1-31 REV 03.10 ISS 13NOV13 Copyright Trademarks and patents Manufacturer Version Certification European Union directives Contact information 2013 UTC Fire
More informationIntelligent Security & Fire Ltd
Product Data Sheet Mx-4000 Series User Manual MX-4100, MX-4200, MX-4400, Mx-4400/LE & Mx-4800 Fire Alarm Control Panels The operation and functions described in the manual are available from Software Versions
More informationTX7110. Intelligent Heat Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.
TX7110 Intelligent Heat Detector Installation and Operation Manual Technology Copyright 2015, All right reserved. Product Safety To prevent severe injury and loss of life or property, read the instruction
More informationColour Observation System
FAR < > NEAR Colour Observation system talk action menu _ + auto next FAR < > NEAR Colour Observation Monitor Colour Observation Monitor English Colour Observation System Table of contents Page Introduction...3
More informationDatasheet CALYPSO II R. Interlinkable smoke alarm device
Datasheet CALYPSO II R PRESENTATION Calypso II R is a home smoke detector with integrated radio link. Conceived for individual houses and flats, Calypso II R detects smokes coming from incipient fires
More informationNookBox Installation Guide Keypad. Installation Guide. NookBox Keypad (P / E )
1 Installation Guide NookBox Keypad (P119010 / E6309744) 2 NookBox Keypad (P119010 / E6309744) 3 Parts Identification 1. Active LED 2. Status LED 3. Fault Display LED 4. Arm Key 5. Home Key 6. Key Check
More informationS3 Sim Secual Alarm system with GSM transmitter
S3 Sim Secual Alarm system with GSM transmitter www.etiger.com Features Control Panel Layout (Back) - ARM CPU + Auror CPU - GSM frequency: 850 / 900 / 1800 / 1900 MHz, suits all phones - Supports up to
More informationKM300 Carbon Monoxide Detection System Installation Manual
GE Security KM300 Carbon Monoxide Detection System Installation Manual P/N 1068922 REV 2.0 16SEP09 Copyright Copyright 2009 GE Security, Inc. All rights reserved. This document may not be copied in whole
More informationSECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS
SECURITY SYSTEM NOTES Installing/Service Company For Service Call SPECIAL CODES "Chime" Digit 1 "Partial Arm" Digit 2 "Quick Arm" Digit 3 ENTRY / EXIT DELAY TIMES Exit Delay Time Entry Delay Time Secondary
More informationWireless Keypad GKP-S8M
Wireless Keypad GKP-S8M User manual Contents Congratulations on your purchase of this Honeywell wireless keypad. To make the best out of your equipment we advise you to read this manual carefully. This
More informationDS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel
DS9400 Series EN Release Notes for Firmware V2.07 Fire Alarm Control Panel DS9400 Series Release Notes for Firmware V2.07 Trademarks Trademarks Gentex is a trademark of Gentex Corporation, Fire Protection
More informationTECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel
CVENTIAL ALARM S Features: Description: The LF-CP Series Fire Alarm Control Panel is manufactured based on advanced technology while maintaining high quality during assembly. It is of solid state circuitry
More informationZP2 Series Operation Manual
ZP2 Series Operation Manual P/N 501-405203-2-31 REV 03.10 ISS 07NOV13 Copyright Trademarks and patents Manufacturer Version Certification European Union directives Contact information 2013 UTC Fire & Security.
More information10 Year Smoke Detector and Siren
10 Year Smoke Detector and Siren SKU: POPE009402 Quickstart This is a secure Alarm Sensor for Europe. To run this device please insert fresh 1 * LS14250 batteries. Please make sure the internal battery
More informationEN ES-D5B Wireless Smoke Detector. Instrukcja pobrana ze sklepu
EN 14604 ES-D5B Wireless Smoke Detector Instrukcja pobrana ze sklepu www.ekocentrum24.pl EN Contents Introduction............... 3 Box Content............... 3 Specifications. 4 Installation. 4 Connect
More informationTransponder reader TECHNICAL SHEET (White) (Magnesium)
TECHICAL SHEET 5739 48 (White) (Magnesium) Description The transponder reader is a device that activates when the appropriate badge is laced in front of it (1-2 cm). The badge is the transponder. The signal
More informationIntruder alarm system Operating Instructions
Intruder alarm system Operating Instructions 0 2 3 4 5 6 7 8 9 CHIME OMIT RESET PROG SET S Power 0 2 3 5 6 7 8 Chime Omit Prog 4 9 Set AccentaG3 mini Servicing organisation details Servicing organisation
More informationEi600ZW Z-Wave Module for 10 Year Smoke Sensor with Siren
Ei600ZW Z-Wave Module for 10 Year Smoke Sensor with Siren Quick Start This device is a combination of a Z-Wave sensor (smoke sensor) and a Z-Wave actuator. Pressing the button 'Inclusion Button' for one
More informationPROGRAMMING PROCEDURES (Table 3)
CONDOPLEX 2600/2600A/2700 Suite Panel User Manual Document Version 8.4 Oct 19, 1998 Condoplex 1998 PROGRAMMING PROCEDURES (Table 3) FUNCTION PRESS KEYPAD DISPLAY Delete user code or duress code. 0 (hold)
More informationIntelligent addressable fire alarm control panel
Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity
More informationINSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder
INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder 1) Introduction The Appello tone and speech annunciation sounder has three different styles in AC and DC. A105NAPPX
More informationCentaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE
Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE General Description This guide provides a summary for installing and configuring the Centaur TM Cube Slave Alarm Signalling Equipment
More informationInstallation Manual. Premier IXP-W INS538
Installation Manual Premier IXP-W INS538 1. Contents 1. Contents... 2 2. Premier IXP-W Interface... 3 Premier 8XP-W & 32XP-W Firmware... 3 3. Quick Start Guide... 4 4. System Overview... 5 Mounting the
More informationConventional Fire Alarm System 2014 V1.2
Conventional Fire Alarm System 2014 V1.2 Product Overview Control Panel 2 Conventional Fire Panel GST102A 2 zone Fire panel GST104A 4 zone Fire panel GST108A 8 zone Fire panel GST116A 16 zone Fire Panel
More informationInterface Modules for SENTRI
EQUIPMENT INTERFACED Data and Installation Interface s for SENTRI Low voltage (LV) / SEN-INT-INPUT 1- Interface (low voltage) SEN-INT-OUTPUT 1- & 1- Interface (low voltage) SEN-INT-4IO # 4- / Interface
More informationstatus AW1 Plus WiFi Alarm System User Manual
status AW1 Plus WiFi Alarm System User Manual Foreword Congratulations on your purchase of the AW1 Plus Alarm system. Before you commence installation we recommend that you unpack the product, familiarise
More informationTesting the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)
F A 1 7 0 0 c Testing the System Battery Test When AC power is present, the FA1700C runs a brief battery test every 60 seconds to determine if there is a battery connected, and runs an extended battery
More informationUniversal Sensor. Installation Guide. t: f: e: w: uk.tunstall.com Version: V2.97 (421V0R1.
Universal Sensor Installation Guide t: 01977 661234 f: 01977 660562 e: enquiries@tunstall.com w: uk.tunstall.com Version: V2.97 (421V0R1.18) Contents 1. Features and Introduction... 3 Your Universal Sensor...3
More informationWireless Keypads LKP(E)S8M Series
Wireless Keypads LKP(E)S8M Series User manual Contents Congratulations on your purchase of this Honeywell wireless keypad. To make the best out of your equipment we advise you to read this manual carefully.
More informationPRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual
PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual Contents I. SPECIAL FEATURES 1 II. FRONT PANEL 1 III. INSTALLATION PROCEDURES AND PROXIMITY CARD TYPES 2 IV. SETTING
More informationTotal Connect Box. User manual
Total Connect Box User manual 1 Congratulations on your purchase of the Honeywell Total Connect Box security system. To make the best out of your system we advise you to read this manual carefully. This
More informationLC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV
LC1 & 2 Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV ZIRCONLC1 One Zone Conventional Fire Panel ZIRCONLC2 Two Zone Conventional Fire Panel Compliant with EN54-2:1998 & EN54-4:1998
More informationAccenta/Optima. User Guide. UK Security Panels. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number:
Accenta/Optima User Guide ZONE 1 2 3 4 5 6 7 8 9 Chime Omit Prog PA 0 1 2 3 4 5 6 7 8 9 CHIME OMIT RESET PROG SET Accenta + TA PA DAY POWER PA! " # $ % & 0 1 2 3 5 6 7 8 Chime Omit Reset Prog 4 9 Set PA
More informationR-Series Remote Annunciators and Expanders Installation and Operation Guide
R-Series Remote Annunciators and Expanders Installation and Operation Guide P/N 3100969-EN REV 05 ISS 06MAY13 Copyright Trademarks and patents Manufacturer Version FCC compliance Contact information 2013
More informationProduct Data Sheet. Remote Terminals. Features:
Remote Terminals Product Data Sheet Features: Based around two core products, the Mx- 4010 Remote Display Terminal (RDT) and the fully functional Mx-4020 Remote Control Terminal (RCT). Both remote terminals
More informationPRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual
PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual Contents I. SPECIAL FEATURES 1 II. FRONT PANEL 1 III. INSTALLATION PROCEDURES AND PROXIMITY CARD TYPES 2 IV. SETTING
More information"Pegaso" wireless alarm system
"Pegaso" wireless alarm system Summary Page 1.0. Description... 2 2.0. Installation... 3 3.0. Connections to mains power... 4 4.0. Low battery signalling... 4 5.0. Service key... 5 6.0. Selection of functions...
More informationUSER S MANUAL HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY
+ USER S MANUAL 1.0 HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY SECURITY KEYPAD WITH PROXIMITY TAGS PREVENTION OF WATER DAMAGES
More informationSyncro AS. Analogue Addressable Fire Control Panel. User Manual
Syncro AS Analogue Addressable Fire Control Panel User Manual Man-1100 Issue 02 Nov. 2008 Index Section Page 1. Introduction...3 2. Safety...3 3. Panel Controls...4 3.1 Access Level 1...4 3.2 Access Level
More informationMobeye CM2410 GSM fire alarm communicator
PORTAL USER MANUAL Mobeye CM2410 GSM fire alarm communicator Accessory for Ei Electronics fire detector SW version 5.n Incl. CM2400 Attention! Very important This user manual contains important guidelines
More informationTS400 & TS410. Intruder Alarm Control Panels. Operating Instructions
TS400 & TS410 Intruder Alarm Control Panels Operating Instructions Zone Location Home Set Chime 1 Armed / Omitted 2 Armed / Omitted 3 Armed / Omitted 4 Armed / Omitted 5 Armed / Omitted F. Exit Always
More informationSmartLINK Module Ei3000MRF for Mains Powered Multi-Sensor Fire / Smoke / Heat / CO Alarms - Ei3000 Series
SmartLINK Module Ei3000MRF for Mains Powered Multi-Sensor Fire / Smoke / Heat / CO Alarms - Ei3000 Series Instruction Manual Read and retain carefully for as long as the product is being used. It contains
More informationALC-PACK3. WiFi Alarm System with HD WiFi Camera. User Manual. Your Watchguard Wireless Security professional:
status ALC-PACK3 WiFi Alarm System with HD WiFi Camera User Manual Your Watchguard Wireless Security professional: www.activeonline.com.au 1300 816 742 Foreword Congratulations on your purchase of the
More informationPremier External TD. Installation Manual INS352-3
Premier External TD Installation Manual INS352-3 1. Accessing the Unit 1 2 Remove the top cap and loosen screw (screw retained in wall plate). Push up head unit and remove. 3 Use a flat head screwdriver
More information"Pegaso" wireless alarm system D.I.Y. wireless kit
"Pegaso" wireless alarm system D.I.Y. wireless kit Summary Page 1.0. Description... 2 2.0. Installation... 3 3.0. Connections to mains power... 3 4.0. Low battery signalling... 4 5.0. Service key... 4
More information4 wire conventional alarm system
Scimitar 4 wire conventional alarm system from Channel Safety Systems Scimitar 4 wire conventional alarm system The Scimitar Fire Alarm Control System is a comprehensive range of high specification conventional
More informationPOP_ Smoke Detector
POP_004308 Smoke Detector Firmware Version : 1.0 Quick Start S This device is a wireless Z-Wave sensor. Exclusion, Inclusion are confirmed by hitting the programm button for 1 sec when the sensor is removed
More informationControl/Communicator
Architectural & Engineering Specifications Control/Communicator 1.0 GENERAL... 2 1.1 SCOPE OF WORK... 2 1.1.1 Introduction... 2 1.2 GENERAL CONDITIONS... 2 1.2.1 After-Sales Support... 2 1.2.2 Quality
More information5 Sounds and Indications
5 Sounds and Indications 5.1 Sounder Tones Mode: Tone: 5.2 Indications Exit Soft continuous tone Fault on exit Soft intermittent tone Entry Soft pulsing pips Walk test Soft pulsing pips Keypad entry Soft
More informationInteractive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -
Security System Owner s Manual Interactive Technologies Inc. 2266 North 2nd Street North St. Paul, MN 55109 FCC Notices FCC Part 15 Information to the User Changes or modifications not expressly approved
More informationInstallation and Operation Manual
[Please read this installation & operation manual before install and use this Installation and Operation Manual Address: 8-701,Dongfangming Industry Zone, Dabao Road., Baoan, Shenzhen, China-518101 Page
More information5000 INSTALLATION GUIDE
5000 INSTALLATION GUIDE Table of Contents Section Page No 1. INTRODUCTION... 3 2. WARNINGS AND CAUTIONS... 3 3. UNPACKING... 3 4. INSTALLATION... 4 5. CONTROL PANEL - REMOVING ITEMS BEFORE MOUNTING...
More informationINSTALLATION GUIDE XTLN-WIFI PANEL
INSTALLATION GUIDE XTLN-WIFI PANEL MODEL XTLN-WiFi INSTALLATION GUIDE FCC NOTICE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of
More informationPOP_ Smoke Detector
POP_004308 Smoke Detector Firmware Version : 1.0 Quick Start S This device is a wireless Z-Wave sensor. Exclusion, Inclusion are confirmed by hitting the programm button for 1 sec when the sensor is removed
More information1117RX Series - 8 & 16 Zone Wireless 868MHz Radio Duress/Panic Alarm System For Bank Santander Branches
1117/1150 8 & 16 zone Santander instructions - Nov 2013 1117RX Series - 8 & 16 Zone Wireless 868MHz Radio Duress/Panic Alarm System For Bank Santander Branches Installation & User Manual 1117RX System
More informationVersion 1.03 January-2002 USER S MANUAL
Version 1.03 January-2002 1 USER S MANUAL 2 Version 1.03 January-2002 System Details CUSTOMER:...... PHONE:... FAX:... INSTALLED BY:...... PHONE:... FAX:... MAINTENANCE & SERVICE:...... PHONE:... FAX:...
More informationG34 AU1B (External Ultrasonic Sensor) Version 3
Car Alarm Series 3 B 4 Buttons G34 AU1B (External Ultrasonic Sensor) Version 3 24 CAR ALARM GENIUS Series 3B 4 Buttons G34 AU1B (External Ultrasonic Sensor) Module controlled using Micro-Processor 2 Transmitters
More informationZX1e ZX2e ZX5e. Document No Issue 01 user manual
ZX1e ZX2e ZX5e Document No. 996-130 Issue 01 user manual MORLEY-IAS ZX2E/ZX5E Fire Alarm Control Panels Table of Contents 1 INTRODUCTION... 4 1.1 NOTICE... 4 1.2 WARNINGS AND CAUTIONS... 4 1.3 NATIONAL
More informationThe system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.
FireCell Radio Hub Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication Loop powered Diagnostics port Range in excess of 150 metres Overview The model FCX-500-001
More informationGE Security. Challenger V8 & V9. User Manual
GE Security Challenger V8 & V9 User Manual Copyright Disclaimer Trademarks and patents Intended use Copyright 2008, GE Security Pty. Ltd.. All rights reserved. This document may not be copied or otherwise
More informationUser Manual. Dryer Controller M720
User Manual Dryer Controller M720 Hardware version 1.00 Software version 1.00 Preliminary version Manual M720 Dryer controller Page 1 of 42 Document history Preliminary version: - Created in April, 2009
More informationFlash 3 times per 3 seconds: Under voltage indication, please
VOH1007 VOH1007 is a high performance wireless pet immunity P.I.R. motion detector. It consists of digital dual-core fuzzy logic infrared control chip and intelligent analysis which effectively identify
More informationADE Gen4. Speech Dialler Engineering Information. Description. Features
ADE Gen4 Speech Dialler Engineering Information Description The Informa is a Speech Dialler for use with intruder alarm systems. When the control panel recognises an alarm it triggers the Informa. The
More informationInstallation Manual Premier Elite IXP-W
Installation Manual Premier Elite IXP-W INS538-2 1. Contents 1. Contents... 2 2. Premier IXP-W Interface... 3 Premier Elite 8XP-W & 32XP-W Firmware... 3 3. Quick Start Guide... 4 4. System Overview...
More information/10 Rev A
VISTA-128BPT/ VISTA-250BPT/ VISTA-128BPTSIA Commercial Burglary Partitioned Security System With Scheduling User Guide 800-06905 6/10 Rev A Your Honeywell security system is designed for use with devices
More informationPERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS
PERS-600 PERSONAL EMERGENCY REPORTING SYSTEM BY BY INSTALLATION & OPERATION INSTRUCTIONS (760) 8-7000 USA & Canada (800) -587 & (800) 9-0 Toll Free FAX (800) 68-0 www.linearcorp.com CONTENTS CONTROL AREA
More informationGRADESHIFT UDL INSTRUCTION MANUAL 2.5 APPENDIX
GRADESHIFT UDL INSTRUCTION MANUAL 2.5 APPENDIX GradeShift UDL Instruction Manual 2.5 Appendix 2.5 APPENDIX SPECIFICATIONS Dimensions 21 mm (h), 132mm (w), 94mm (d) Weight 140g including NVM and SIM Temperature
More informationINSTALLATION AND USER MANUAL SG2. GSM+WiFi. Alarm Security System
INSTALLATION AND USER MANUAL GSM+WiFi Alarm Security System SG2 SIM Features - 16-bit high speed processor, reliable capability - 100% wireless D.I.Y. - Built-in 1,000,000 RF codes - Supports 10 remote
More informationInstruction Manual Water Sensor
Instruction Manual Water Sensor Thank you for your support Please read the instruction manual carefully before operating Please keep the instruction manual for future reference Shenzhen NEO Electronics
More informationINSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder
INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder 1) Introduction The Appello tone and speech annunciation sounder has three different styles in AC and DC. A105NAPPX
More informationArea Systems While the alarm bell or siren is sounding, enter your user code. The system silences the alarm bell or siren.
XR20 User s Guide Silencing an Alarm All/Perimeter and Home/Away Systems While the alarm bell or siren is sounding, enter your user code. The keypad displays DISARM SILENCE. Press the Select key under
More information2G & 3G GSM Door Contact Alarm
2G & 3G GSM Door Contact Alarm www.gsm-activate.co.uk MODEL RF - PIR PAGE 1 Product Information Our 2G/3G GSM Door Contact Alarm is a standalone alarm system for smaller rooms inside properties. It will
More informationTechnical Manual. Level Alarm Unit CARLA & WIDS
CARLA & WIDS Technical Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Technical Manual CARLA for Tankers Cargo Tanks
More informationELT-KLED EliteSuite LED Keypad Installation Manual
ELT-KLED EliteSuite LED Keypad Installation Manual ELT-KLED EliteSuite Installation Manual PUBLICATION INFORMATION First Publication Draft Document Release Only Updated fire zone information Second Publication
More informationINTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3
INTELLIGENT FIRE TECHNOLOGY Twinflex and Multipoint V3 User Guide (TO BE RETAINED BY USER) 26-0340 Issue 3 Rafiki Protection Limited Rafiki policy is one of continual improvement and the right to change
More information4100U City and Relay Cards Installation Instructions
4100U City and Relay Cards Installation Instructions Introduction This publication describes the installation procedure for the following: 4100-6031/6032 City Circuit Cards 4100-6033 Alarm Relay Card Inspecting
More informationRef.1067/032 Ref.1067/042
DS1067-033A Mod. 1067 LBT8631 BUS CONTROL PANEL 8/32 INPUTS Ref.1067/032 Ref.1067/042 USER MANUAL TABLE OF CONTENTS 1 PREFACE... 5 2 COMMAND DEVICES... 6 2.1 1067/021 DISPLAY KEYPAD... 6 2.2 ELECTRONIC
More informationBT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL
BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL 26 Aug 2015 V1.8 Page 1 SECTION CONTENTS PAGE NO. 1.0 SYSTEMS DESCRIPTION 1.1 General descriptions 2 1.2 Master Alarm PCB 2 1.3 Zone Display Board 2 1.4
More informationMatrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1
Matrix2000 User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 s Version: 2.0 Revision: 1 IMPORTANT INFORMATION Limitation of liability It is mandatory, Matrix2000 panel to be installed in accordance
More informationEthernet General Purpose
Ethernet General Purpose Technical Manual Revision 1.03 8 November 2013 Pakton Technologies IO PAE224 Ethernet GPIO Manual.docx Page 1 of 22 Revision 1.03 Last updated 8/11/2013 Table of Contents INTRODUCTION...3
More information