1 B/W Controls SERES 41 SOLD STATE ALARM SYSTEM SECTON 1 VERSATLE NEW BW ALARM SYSTEMS DETECTS MOSTURE, LEAKS, HGH LEVELS PLUS MANY OTHER OFF-NORMAL CONDTONS.. tim. FEATURNG: General purpose or industrial and weatherproof enclosures Field-adjustable sensitivity from 1000 ohms to 1 megohm Low energy sensing circuit ideal for liquid level electrodes or pilot switches Field-adjustable time delay 0 to 3 sec. to eliminate false trips Ability to operate from remote sensors

2 SECTON B/W Controls VERSATLE NEW ALARM DETECTS MOSTURE, LEAKS AND HGH LEVELS, PLUS OFF-NORMAL COND TONS NVOLVNG A WDE VARETY OF PROCESS VARABLES AND BULD NG SECURTY APPLCATONS BW Series 41 Solid-State Alarm Systems are designed to provide new versatility, safety and reliability in monitoring and detecting off-normal conditions in a broad range of industrial, commercial and institutional applications. Key feature of the system is its low energy adjustable sensing circuit which assures reliable operation from electrodes contacting conductive liquids or from contact-type pilot devices such as flow, float, pressure and limit switches, thermostats and pushbutton actuators, etc. As a result, the system can be used to detect moisture or leaks in mines, underground communication networks, boat bilges, computer rooms, libraries, archives and record storage areas. t is also ideal for monitoring dangerous high level conditions in storage tanks, cooling towers, storm drain sumps, septic tanks, sewer systems, lakes, streams, and other locations requiring detection of overflow or flooding. n addition, because Series 41 Alarms will also operate from contact-type pilot devices, they are equally suitable for use in monitoring process variables such as temperature, pressure, flow, humidity, voltage and current, etc., as well as building security and fire detection alarms. nstallation is quick and easy with saddle clamp barrier terminal blocks for 1 to 18 gauge wire, or ring terminal connections to field wiring. OPERATNG FEATURES AND ADVANTAGES BW Series 41 Alarm Systems also provide field-adjustable sensitivity from 1000 ohms up to 1 megohm to assure reliable operation over long distances and in detecting leaks or high levels of a wide variety of conductive liquids. A field-adjustable time-delay is also provided to eliminate false trips due to liquid turbulence or electrical transients. The alarm action does not start until the time delay is completed. Other features include: A SPOT auxiliary relay which has its coil energized when the process condition is normal so that its contact can be used to provide fail-safe remote signal, alarm or cut-off of pumps, valves, motors and other operating equipment in the event of a component or power failure. A holding circuit which permits operation over a range of levels or from momentary contact switching devices. lluminated SLENCE and TEST pushbuttons and optional manual RESET button. SNGLE ALARM PERFORMS MULTPLE FUNCTONS Regardless of usage, however, a single alarm system may be applied with several electrodes or pilot devices connected in parallel to provide an audible alarm in the event a fault condition occurs at one or more of the remote detection points being monitored. Moreover, the low voltage and low current level of the sensing circuit permits use of low cost small gauge unshielded communication wires for long distance alarm installations. BASC SPECFCATONS: Voltage: Standard: 115 volts ac- 50/ 60 hertz Optional: 30 volts ac- 50/ 60 hertz. 4 volts. de. Power Required: General Purpose Model ndustrial & Weatherproof with 6" Bell with Horn 6VA 11 VA 15 VA Contact Rating: Single pole, double throw; 6 amperes resistive load at 10 volts ac. Sensing Circuit: 4 volt de and 0.5 milliamperes maximum. Sensitivity field adjustable from 1000 ohms up to 1 megohm. Time Delay: Adjustable from 0 to 3 seconds. Pushbuttons: SLENCE and TEST buttons are standard. RESET button is optional. GENERAL PURPOSE MODEL For indoor service in a steel enclosure with a solid state audible alarm. NDUSTRAL & WEATHERPROOF MODEL For outdoor or indoor service in a fiberglass enclosure and with choice of a horn or a 6 inch bell. DESCRPTON OF OPERATON STANDARD SEQUENCE is automatic reset with silence pushbutton and without lock-in, SA designation A-1-4, with the extra feature of an adjustable time delay after the fault condition occurs which delays the alarm action for the set time period. The auxiliary SPOT contact is a fail safe arrangement that follows the alarm light status. The test pushbutton provides full operational test simulating an abnormal condition. MANUAL RESET SEQUENCE operates the same as the standard sequence except that a momentary fault condition will lock-in the alarm status until the condition returns to normal, and the reset pushbutton is operated. The SA sequence designation is M-1. Sensing Process Circuit Line Condition Status 1 Normal Open Normal Open 3 Normal Open 4 Abnormal Closed 5 Abnormal Closed 6 Normal Open Operation for Manual Reset Push Button Model 6A Abnormal Closed 68 Normal Open Operator Push Button Action SEQUENCE TABLE Alarm Status Test Silence Reset Light Audible Push Off Off Flashing Flashing On On Push On Off This option will lock-in a momentary abnormal condition at the status of line 4. After the condition returns to NORMAL, an operator action is required to reset alarm status. Line 6 is replaced by the following action. Push Flashing On Push Off Contact Status A B Remarks Closed Open Line voltage - off Open Closed Line voltage - on Closed Open Status goes to Line 4 Closed Open Alarm occurs after time delay which is adjustable 0-3 seconds Closed Open Open Closed Automatic Reset Closed Open Open Closed Abnormal condition is locked-in Status goes to Line 4 and must silence again CATALOG 79

3 B/W Controls SECTON 3 TYPCAL APPLCATONS Diagrams below illustrate basic details of typical installations ir1 which Series 41 Alarm Systems are used to monitor and detect any off-normal conditions in applications involving the control of liquids and various common in-process variables. ~ J... SUGGESTED CONTROL SETTNGS Sensitivity: Set to a value greater than the specific resistance of the liquid to be controlled. Time Delay: Normally 0- second or just long enough to prevent nuisance alarms resulting from wave action of the liquid. n Diagram A, the system consists of one electrode set at the predetermined danger level and a second common electrode set at the same or a slightly lower level to complete the sensing circuit. n Diagram B, the jumper is removed from terminal block and a third reset electrode is used. The alarm will then go off automatically when liquid falls below the reset electrode. Diagram C is essentially the same except a normally-closed pushbutton is used to lock in alarm instead of a reset electrode. n Diagram D, a good ground return to the liquid is used to complete the sensing circuit instead of a common electrode. OPERATON FROM ELECTRODES Diagram A - High Level Alarm or Leak Detection System Diagram B - High Level Alarm or Leak Detection System with Automatic Reset Electrode ~ =-JuMPER---l ~-JUMPER-REMOVED] ~ pi / ELECTRODE HOLDER ~===-=--=--=-~- -~ 1 A~:~T~~DE HOLDER SENSNG CRCUT SENSNG CRCUT ABOVE THS LEVEL TERMNAL STRP ALARM ON ABOVE THS LEVEL TERMNAL STRP ALARM OFF BELOW THS LEVEL COMMON COMMON ALARM OFF ELECTRODE ELECTRODE BELOW THS LEVEL Diagram C - High Level Alarm or Leak Detection System with Lock-n and Reset Pushbutton r-j"l!mp"efl FiENioVEo - - ~ L -~- _j -El ~~;~-:~Lt / ELECTRODE HOLDER RESET 1 ALARM ON PUSHBUTTON ABOVE THS LEVEL SENSNG CRCUT COMMON ELECTRODE TERMNAL STRP Alarm will lock in until level falls below electrode and reset button is operated. Diagram D - High Level Alarm Operated from Ground Return instead of Common Electrode - JUMPER ~ ELECTRODE HOLDER -, ALARM ON l ~ -:!:- ABOVE THS LEVEL L_AGOOD ALARM OFF DEPENDABLE BELOW THS LEVEL ROUND RETURN _[ TO THE LQUD S =-. J REQURED L...J SENSNG CRCUT TERMNAL STRP SUGGESTED CONTROL SETTNGS Sensitivity: Normally set at minimum of 1000 ohm except when operating from a resistance transducer. Time Delay: Normally 0-1 second or just long enough to prevent nuisance trips. n Diagram E, the Series 41 Alarm is used with a BW Unifloat multiple switch level sensing assembly which can be applied to control any non-conductive or conductive liquid. n Diagram F, a remote pilot device is used to actuate the alarm in event of off-normal conditions such as temperature, smoke, pressure, flow, proximity, etc. Diagram G is similar except jumper at terminal block is removed and a normally closed pushbutton is used to lock in alarm. n Diagram H, a transducer that lowers resistance is used to sense any off-normal condition and trip the alarm. OPERATON FROM PLOT SWTCHES Diagram E - Hi!;Jh Level Alarm System Operated from B fw Unifloat common wire may be omitted if Terminal 6 is grounded. Diagram G - Security or Fire Alarm Operated from Pilot Device with Lock-n and Reset Button ~~@(~(~~~OVED- - ~CONTACT OF 1:@:----: ---~- -- _j PLOT DEVCE NC MANUAL ALARM ON WHEN LJ RESET CONTACT CLOSES PUSHBUTTON L_~ j SENSNG CRCUT TERMNAL STRP Alarm will lock-in until contact of pilot device opens and reset button operated. Diagram F - Process Alarm with Remote Pilot Switch Actuated by Off - Normal Conditions L ~~R~~~WHEN CONTACT S OPEN - JUMPER _1.. CONTACT OF, - PLOT DEVCE ALARMON-W~EN CONTACT S CLOSED SENSNG CRCUT TERMNAL STRP o ff-normal conditions may be temperature, smoke, pressure, humidity, flow, proximity, counter, voltage, current depending on type of pilot device used. Diagram H - System with Device that Reduces Resistance when Actuated by Fault Condition L.=JuMPER f.3!-rn- PHOTO CELL 1 OR MOSTURE DETECTOR ETc. SENSNG CRCUT TERMNAL STRP *Alarm sounds when sensing circuit resistance drops below sensitivity set point.

4 SECTON 4 B/W Controls GENERAL PURPOSE MODEL AUDBLE ALARM ELECTRONC TYPE 73db SLENCE PUSHBUTTON WTH RED LGHT TEST PUSHBUTTON WTH GREEN LGHT WRNG DAGRAM ADJUSTABLE TME-DELAY 0 to 3 SECONDS ADJUSTABLE SENSTVTY 1000 OHMS TO 1 MEGOHM rm, H } SENSNG CRCUT 4 VOLTS DC AND e o MA MAXMUM.> BARRER-TYPE TERMNAL STRPS AUXLARY CONTACTS - A & B DMENSONS f! ~~~r=::-- ~b~~~ng HOLES ll PADLOCK-TYPE DRAW PULL CATCH AUXLARY RELAY CONTACT C l. ~- ~- ~- ~- ~ OPERATON N EVENT OF ALARM t o_"!'!'~."-.j i : ' ' OR POWER OR RELAY FALURE -- ~~!'!'!«! _A ) : i t._} LNE VOLTAGE CONTACT"' A" CLOSES ---~~'!ti'~!.!'.j ~ VOLTS AC- 50/ 60 HERTZ AND CONTACT " B" OPENS 1" &1114" KNOCKOUTS The General Purpose Enclosure is made of 16 ga. steel with gray baked enamel finish and is intended for indoor applications. NDUSTRAL AND WEATHERPROOF MODEL WRNG DAGRAM AUDBLE ALARM Horn - Grille type, Adjustable 70 to 103 db. ' Bell - 6 inch Gong 9 db. at 10 ft. ADJUSTABLE TME DELAY 0 to 3 SECONDS SLENCE PUSHBUTTON - H - -, WTH RED LGHT TEST PUSHBUTTON WTH GREEN LGHT The enclosure is molded fiberglass in machine tool gray color with a closed cell neoprene cover gasket. t is rated NEMA 1 oiltight and dust-tight, and also meets NEMA 3 requirements for outdoor installation. The cover devices are watertight industrial quality. The stainless steel hinge and latch conform to NEMA 4X cor- ADJUSTABLE SENSTVTY 1000 OHMS TO 1 MEGOHM - +}SENSNG CRCUT 4 VOLTS DC AND MA MAXMUM BARRER-TYPE TERMNAL STRPS AUXLARY CONTACTS TRANSFORMER rosion resistance standards, however, in order to meet the severe NEMA 4 watertight hose test, screw cover fasteners are required rather than the luggage latch. This option is available and if required specify "NEMA 4X Watertight" when ordering. llfl -CJ DMENSONS ~ "il, (] ill1 o 0 o r BELL 7.75 HORN 7.06 r~=======::::j LY=='====="=--- 4 MOUNTNG HOLES.313 DAMETER OPTONAL COVER SCREWS FOR NEMA 4X RATNG LUGGAGE LATCH WTH PADLOCKNG HASP NO CONDUT OPENNGS ARE PROVDED. CONDUT HUBS ARE AVALABLE FOR FELD MOUNTNG. 'CATALOG 81

5 B/W Controls SERES 41 SOLD STATE ALARM SYSTEM SECTON S 601 AND 6013 BW LEVEL SENSNG ELECTRODE EQUPMENT CAST ELECTRODE HOLDERS PLASTC ELECTRODE HOLDERS ce Free Pressure nght Flanged Cast ron Conduit Flanged PVC Molded 7014 UNFLOAT MOSTURE SENSOR Switches continue to operate even during power failure Simple level adjustment without disturbing tank connection. Single float for up to 1 sensing levels deal in non-conductive liquids such as gasoline, fuel oil and chemicals UL Recognized Encapsulated reed switches provide dry contact for direct interface to programmable controllers in. or 3 in. Pressure-tight holder Pressure-Tight " or3" NPT 'iu U.L. Recognized Component Low Level Reed Switch Float Stop & Tube Seal U.S. Patent No. 4,056,979 The moisture sensor is a compact, low cost device which can be easily attached with two screws or with the adhesive provided. When moisture bridges adjacent printed circuit paths on the surface of the sensor, the Series 41 Alarm System will provide an audio-visual indication and isolated SPOT contacts for auxiliary control. The BW moisture sensor is ideal to detect water under computer room floors, in communication vaults, in archives, in below grade ductwork, on floors in basements, storage areas or equipment rooms. BW system of low voltage low current sensing permits use of inexpensive field wiring between sensor and alarm. See Catalog Section 6013 for detailed information. 'CATALOG 8

6 SECTON 6 SERES 41 SOLD STATE ALARM SYSTEM B/W Controls Series 41 alarm system with the general purpose enclosure and a reset button shown with a conduit holder with wire suspension electrodes. Series 41 alarm system with the general purpose enclosure shown with BW Moisture Sensors. Series 41 alarm system with the industrial enclosure shown with a molded electrode holder. CATALOG NUMBERNG SYSTEM AND LST PRCES SERES 41 ALARM SYSTEM WTH GENERAL PURPOSE NEMA 1 ENCLOSURE DSCOUNT SCHEDULE LL 1 Prices Subject to Change Without Notice L R N1 CATALOG ~ SECTON LST LST LNE VOLTAGE PRCE OPTONS PRCE a... L1 115 VAC 50/ 60Hz $ X No Addition L 30 VAC 50/ 60 HZ $118:88 R Reset Add L3 4 VDC $i Button SERES 41 ALARM SYSTEM WTH NDUSTRAL OR WEATHERPROOF ENCLOSURE H R N3 CATALOG SECTON LST*... LST ALARM TYPE PRCE OPTONS PRCE s 6" Bell 9db $ lx Ad~Wion H Horn db eooum. R Reset Add Button *For 115 VAC 50/60HZ line voltage only. Contact factory for optional 30 VAC 50/60 HZ prices. ENCLOSURE N3 Meets Nema 3 and Nema 1 N4 Nema 4X Watertight* *See pg. 4 for enclosure description. LST PRCE No Addition Add ~ ~ PVC HUBS - WTH 0 RNG SEAL FOR PLASTC CONDUT CONDUT SZE PART NUMBER Y nch !4 nch CONDUT HUBS LST PRCES LST PRCE... ALUMNUM HUBS - Field installation is simple using standard electrician's hole saw or punch. WTH GROUNDNG SCREW FOR METAL CONDUT CONDUT PART... LST SZE NUMBER PRCE Y nch /4 nch ,. CATALOG 83

7 SECTON 8040 B/W Controls 4 BW Signal and Alarm panels are available in many standard packaged units designed for use in a wide range of high, low and intermediate level alarm applications as well as for remote control signalling. Each contains the proper BW level sensing relays and operates from electrudes set at desired alarm levels. These panels can also be furnished with one or more BW pump control relays included in the package to perform any desired level control function. Also these alarm systems can be incorporated into any of the other control systems shown in this catalog. Contact us for assistance to meet your specific needs. DSCOUNT SCHEDULE LL 1 Prices Subject to Change Without Notice Catalog Number Example 8040-SC1H-H-L1-N S7 X H 0 LSTPR CE RELAY ENCLOSURE ADDT ON SENSTVTY N1 Nema 1 Select from Chart S1-S11 N4 Nema4 Sec pg. 9 N1 Nema 1 LF1,HF Select from Chart Section 500 Page 5 LV1- Select from Chart LNE VOLTAGE LST PRCE HV3-4-5 Section 500 Page 5 ADDTON v Select from Chart L1 115 Volt 50/60 Hz... F1-F8 Section 5300 Page 5 L Volt 50/60 Hz OPTONAL FEATURES Horn instead of Bell... nclude additional relay for control functions. Specify details LST PRCE ADDTON Consult Factory RELAY TYPE 1500 nduction Type L Series 5-low sensitivity 500-H Series 5-high sensitivity 5300-S Series amp contacts 5300-P Series 53-5 amp contacts LST PRCE ADDTON LSTPRC E ADDTON, SV1H NUMBER OF ELECTRODES TYPE OF OPERATON LST PRCE High Level Signal $... Low Level Signal $ - VSUAL SGNALS High and Low Level Signal $ Willi AND ALARMS Three Level Signals $._ Four Level Signals "' ll Signal Lights Only Five Level Signals $ High Level Alarm $~ AUDBLE SGNALS Low Level Alarm s..- AND ALARMS High and Low Level Alarm $ *Bell or Horn Only High Level Alarm s-... *Bell or Horn with Two-Position Low Level Alarm $... Manual Reset Silence Switch Operates from single pole 0 pivot device to indicate any $... COMBNATON VSUAL off-normal condition AND AUDBLE SGNALS AND ALARMS SC1H High Level Signal and Alarm $... SC1L Low Level Signal and Alarm $... Signal Lights *Bell or Horn, SC 3 High and Low Signal and Alarm s...-. Pushbutton Silence Switch High and Low Signal and Alarm SC3 4 Automatic Reset ntermediate Level Signal NOTE: A common electrode is included and it may be omit- *Bell with 4 inch gong is standard ted if a dependable ground return connection to the liquid is 85 db. at 10ft. provided by other means. Horn is optional Adjustable 70 to 103 db. BW Controls CA:;~~ i

:~::d W:::)-!_-...~ L_Il! it-l----~ 115V10 N; El CB20A L21.T2 ~I-----i

:~::d W:::)-!_-...~ L_Il! it-l----~ 115V10 N; El CB20A L21.T2 ~I-----i Panel Wiring Diagram Model EAS-S1 PT LAA 1.1 1.2 1.3 From Main Power Panel 115 VAC, 1 Phase, 60 Hz. Main disconnect l provided by others. ) V :~::d W:::)-!_-...~.---------L_l! it-l----~ 115V10 N; El CB20A

More information

Commercial and Light Industrial Fire Alarm Control Panel

Commercial and Light Industrial Fire Alarm Control Panel FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel Features Easily expandable. All new plug-in board design Two supervised audible circuits Lamp and system trouble circuit test Ground

More information

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual We manage heat MANUAL Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TRACON MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TABLE OF CONTENTS FPT 130 Overview... 2 Installation... 3 Power Source and Load Connections... 4 Temperature Sensor... 5 External

More information

Gas and smoke detectors. (building technology) Gas alarm units. (private home) Gas alarm units (industrial) Gas alarm units. (building technology)

Gas and smoke detectors. (building technology) Gas alarm units. (private home) Gas alarm units (industrial) Gas alarm units. (building technology) Gas and smoke detectors (buldng technology) Gas alarm unts (prvate home) Gas alarm unts (ndustral) Gas alarm unts (buldng technology) Chapter Gas alarm unts Buldng technology Gas alarm unts GS 1.1, GS

More information

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel PROTECTOWIRE FireSystems Features Easily expandable Two supervised audible circuits Lamp and system trouble circuit test Ground fault detection Initiating device circuit (IDC) alarm test Monitors up to

More information

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual MANUAL Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual Model FPT 130 Single Point Freeze Protection Heat Trace Control Table of Contents SCFP-CO-F130 Overview... 3 Installation...

More information

Across-the-Line SERIES MP300 Combined Manual and Automatic

Across-the-Line SERIES MP300 Combined Manual and Automatic Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps

More information

Soft Start Series MP700 Solid State, Reduced Voltage

Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s

More information

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. L Type Anchor Bolt Carbon Steel AISI 304 S.S. ANCHOR BOLT DETAIL Heavy Flat Washer Heavy Hex Nut UNC Th'd Mounting Flange Of Equipment To Be Mounted C B A D Non-Shrink Grout. Poured In Place, After Equipment Setting. Heavy Flat Washer Heavy Hex Nut

More information

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option Installation PS6 SERIES Power Supplies PS6 SERIES Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option Installation and Specifications Manual ISDPS6_SERIES 08121590 PCN15016 R05/15GR

More information

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual From urgent alarms to routine messages, the PD141AFO VIGILANTE handles all types of operational messages with simplicity and economy. The VIGILANTE

More information

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc MASTER PRESSRE MAINTANENCE CONTROLLER Models PMCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page

More information

TECHNICAL BROCHURE BCALARM R4. Indoor and Outdoor Panels and Accessories

TECHNICAL BROCHURE BCALARM R4. Indoor and Outdoor Panels and Accessories TECHNICAL BROCHURE BCALARM R4 Indoor and Outdoor Panels and Accessories FEATURES Indoor and Outdoor alarm panels for sump, effluent and wastewater systems as well as test panel for troubleshooting. Use

More information

SECTION SANITARY SEWAGE PUMP STATIONS

SECTION SANITARY SEWAGE PUMP STATIONS SECTION 11303 SANITARY SEWAGE PUMP STATIONS PART 1 GENERAL 1.1 DESCRIPTION: This work shall include the construction of a sewage pumping station complete with all pumping and electrical equipment, all

More information

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc MASTER JOCKEY PUMP CONTROLLER Model JPCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page 4 Model

More information

Instruction Manual Model A

Instruction Manual Model A 706 Bostwick Avenue, Bridgeport, CT 06605 TEL: 203-368-6751 FAX: 203-368-3747 1-800-566-6822 www.devarinc.com Instruction Manual Model 18-232A LOOP POWERED ALARM MANUAL NO. 990029 MODEL 18-232A LOOP POWERED

More information

Model A1600 Series Annunciator

Model A1600 Series Annunciator Seekirk Model A1600 Series Annunciator Applications: For usage in all types of process industries, electric generation, transmission and distribution, gas and water utilities. Features: The Seekirk model

More information

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual We manage heat MANUAL Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

Type NLC Lighting Control Panels II II SQUARED I:OMPRNY. Class 8931 JUNE, 1982 SupersedeS Catalog Section Dated January Contents Class Pages

Type NLC Lighting Control Panels II II SQUARED I:OMPRNY. Class 8931 JUNE, 1982 SupersedeS Catalog Section Dated January Contents Class Pages FLE: Control Products Catalog Class 8931 SupersedeS Catalog Section Dated January 1981 Type NLC Lighting Control Panels Contents Class Pages Pricing... 8931... 3 Ordering nformation... 8931... 4 Construction

More information

Specification/ Data Sheet

Specification/ Data Sheet Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)

More information

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT TRACON MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT TABLE OF CONTENTS GPT 130 Overview... 2 Installation... 3 Power Source and Load Connection... 4 Temperature Sensor Installation... 5 Panel

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 SPEC WRITER NOTE: Use this section only for NCA projects. Delete between //--// if not applicable to project. Also, delete any other item or paragraph

More information

Oxygen (O2) Single-Point Gas Detection System

Oxygen (O2) Single-Point Gas Detection System Oxygen (O) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in oxygen (O) sensor, accepts one analog remote device such as a secondary gas sensor, temperature or humidity

More information

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL SECTION 16400 AUTOMATIC TRANSFER SWITCHES 1.01 RELATED DOCUMENTS PART 1 - GENERAL A. Drawings and general provisions of Contract, including General Conditions and Division 1 Specification sections, apply

More information

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

ELECTRONIC FLAME SUPERVISION MULTI-BURNER MULTI-BURNER MODEL: SENS-A-FLAME II Revision: 0 7112 DESCRIPTION Model 7112 Sens-A-Flame II is a second generation solid-state programmable combustion safeguard for supervising multiple burner ovens, furnaces,

More information

FDF Foam Pump Controllers Features

FDF Foam Pump Controllers Features FDF100 Diesel Engine Foam Pump Controllers 1-1 Product Description The FDF Series of Foam Pump Controllers are designed for use with foam concentrate injection, foam transfer and water mist systems for

More information

PULL BOXES WITH MANHOLE. -x = co

PULL BOXES WITH MANHOLE. -x = co PULL BOXES WTH MANHOLE PULL BOX: A - 5'x1'x7'H B - 6'x12'x7'H C - 1'6"x16'x8'H D - 1'1"x17'x8'H & FNAL GRADE f3& ~ co 16 :a: Cl ~ H-2 TRAFFC LOADNG A BOX - 1'-" MN. B BOX - 12'-" MN. C & D BOX - 16'-"

More information

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual We manage heat MANUAL Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

Centro-Matic Automated Lubrication Systems System Controls

Centro-Matic Automated Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved RED1 Models ST, E1, E2, E3, E4, and 420 Technical Support And Installation Manual 210111 FM Approved 1. OVERVIEW 1 2. BASIC OPERATION 3 2.1 General 3 2.2 Field-of-View 4 2.3 Range 4 2.4 Environment 4 2.5

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES SECTION 26 36 23 AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts Figure 1Document: SPEC-112 Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts construction requirements of UL approved Class H (180 C) insulation system. Transformers

More information

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description FIREFLEX VACTEC description This FIREFLEX VACTEC integrated fire protection system consists of a vacuum system trim totally pre-assembled, prewired and factory tested. All electrical and mechanical components

More information

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd. F-2000 PC and AO OUTPUT BOARDS INSTRUCTION MANUAL Blue-White R Industries, Ltd. 500 Business Drive Huntington Beach, CA 92649 USA Phone: 714-89-8529 FAX: 714-894-9492 E mail: sales@blue-white.com or techsupport@blue-white.com

More information

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System Nitrogen Dioxide (NO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in nitrogen dioxide (NO)/diesel fume gas sensor, accepts one analog remote device such as a secondary

More information

User Manual. Product: tempmate. -M1 Data Logger Scope: Operations Instructions. For tempmate. -M1 Multiple-Use PDF Temperature Data Logger.

User Manual. Product: tempmate. -M1 Data Logger Scope: Operations Instructions. For tempmate. -M1 Multiple-Use PDF Temperature Data Logger. For tempmate. -M1 Multple-Use PDF Temperature Data Logger Product: tempmate. -M1 Data Logger Scope: Operatons Instructons Summary Theme Page 01. Techncal data 2 02. Devce operaton nstructon 2 03. Intal

More information

Engineered Condensate Solutions

Engineered Condensate Solutions Engneered Condensate Solutons The Mechan of Choce Do you experence mantenance problems wth non-electrc steam/ar powered pus? Are you dung valuable condensate because of frequent mantenance? Do you experence

More information

Pipe Thread Heaters. Construction Features. 1" 2-1/2" Pipe Thread Heaters

Pipe Thread Heaters. Construction Features. 1 2-1/2 Pipe Thread Heaters Construction Features 1" 2-1/2" Pipe Thread Heaters Element bends repressed uniformly to insure electrical insulation integrity. One piece forging of hex, thread and riser assures reliability. Element

More information

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER PNEUMERCATOR Liquid Level Control Systems Electronic Systems Excluding LC2000 And TMS Series MAINTENANCE & TROUBLESHOOTING GUIDE 400 300 500 FUEL LEVEL LEAK MONITOR 1 200 600 OIL/GAS NORMAL WATER PNEUMERCATOR

More information

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G E SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF DATE: 11/13/06 2/1/07 1 Copyright, E, Inc. E 1. ENERAL...4 1.1 Scope Of Work... 4 1.2 Codes and Standards... 4 2. PRODUCTS...5

More information

AlarmLine Addressable Linear Heat Detector

AlarmLine Addressable Linear Heat Detector Line Addressable Linear Heat Detector P/N 7-0001-00 Effective: March 2008 K-7-02 FEATURES UL Listed FM Approved CSFM MEA (pending) Low-cost interface between Line sensor cable and control panel accepting

More information

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES GRUNDFOS CONTROL PANELS Simplex Panel Duplex Panel Standard Features LISTING: Underwriters Laboratories, UL 508. RATINGS: Model S1 rated up to 120 VAC, 1 Hp,

More information

We ve Got Panels Under Control.

We ve Got Panels Under Control. We ve Got Panels Under Control Table of Contents CONTROL PANELS Page # RK Series Single Phase Simplex... A.1 RK Series Single Phase Duplex... A.3 RK Series Three Phase Simplex... A.5 RK Series Three Phase

More information

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING FOR OPERATION FROM 115 AC POWER Andersen Medical Gas 12 Place Lafitte Madisonville, LA 70447 http://www.themedicalgas.com 1-866-288-3783

More information

Model 4001 Series Single Channel Controller

Model 4001 Series Single Channel Controller Model 4001 Series Single Channel Controller Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 (800) 727-4377 (408) 262-9042 - Fax E-Mail: sales@sierramonitor.com Web site:

More information

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-3 ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS Features: For use with doors or groups of doors that must interlock with each other to regulate control of accessing one area from another,

More information

RBC AC1 RUN & STANDBY CONTROL DRAWING NUMBER R1956

RBC AC1 RUN & STANDBY CONTROL DRAWING NUMBER R1956 RBC AC & STANDBY CTROL DRAWING NUMBR R HAND AUTO PANL LIV HATR SUPPLY FAN XTRACT FAN PUMP HATR SUPPLY FAN XTRACT FAN PUMP HATR FAN IMAGS RPRSNTATIV OF DIFFRNT CTROL PANLS IMPORTANT PLAS LAV THIS BOOK WITH

More information

AL600ULADA. NAC Power Extender. Installation Guide

AL600ULADA. NAC Power Extender. Installation Guide AL600ULADA NAC Power Extender Installation Guide Rev. 122000 AL600ULADA - NAC Power Extender Overview: The Altronix AL600ULADA is an extremely cost effective 6.5 amp voltage regulated remote power supply/battery

More information

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description FIREFLEX VACTEC description This FIREFLEX VACTEC integrated fire protection system consists of a vacuum system trim totally pre-assembled, prewired and factory tested. All electrical and mechanical components

More information

DIESEL Engine Fire Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features 1-1 Product Description The FD100 Diesel Engine Controller is designed to control and monitor 12 or 24 volt, diesel fire pump engines. All models are listed by UL and ULC, and approved by Factory Mutual

More information

Public Safety DAS Annunciator Panel

Public Safety DAS Annunciator Panel Public Safety DAS Annunciator Panel 120 VAC Models: 1221-A, 1221-B, 1221-C Revision D 91117 48 VDC Models: 1221-A-48, 1221-B-48, 1221-C-48 24 VDC Models: 1221A-24, 1221-B-24, 1221-C-24 CAUTION: (Read This

More information

Tower & Obstruction Lighting

Tower & Obstruction Lighting Tower & Obstruction Lighting Selection Guide... 10.2 Beacon Flasher FA... 10.4 FS155-... 10.4 FS165-... 10.4 Lamp Monitors Incandescent Lamps FB... 10.6 SCR490D... 10.7 SCR430T... 10.8 SCR630T... 10.8

More information

Mounting Plate ADA/HOSPITAL SIGNALING DEVICES 14-8 FEATURES. > Momentary switch push button > Stainless steel faceplate

Mounting Plate ADA/HOSPITAL SIGNALING DEVICES 14-8 FEATURES. > Momentary switch push button > Stainless steel faceplate Mounting Plate 147-10 > Momentary switch push button > Stainless steel faceplate The Edwards Cat. No. 147-10 Mounting Plate when used with the catalog series 620 Push Buttons (page 10-9) forms a convenient

More information

CM800 Emergency Call System

CM800 Emergency Call System Submittal Package as of 5/25/2017 Phone: 828.524.9967 Toll-Free: 800.327.8466 Sales: Option 2 Tech Support: Option 3 324 Industrial Park Road Franklin, NC 28734 tektone@tektone.net Fax: 828.524.9968 Copyright

More information

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS POINT OBSTRUCTION CONTROLLER Compliances: FAA Advisory Circular 70/7460-1L ICAO Annex 14, Volume I, Chapter 6 The controller provides the control and monitoring functions for an LED red obstruction lighting

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 This section specifies the furnishing, complete installation, and connection of automatic transfer switches. 1.2 RELATED WORK A. Section 14 21 00, ELECTRIC

More information

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F II 1400-2 ACSI 1406-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F INSTALLATION Transformer Model BE31763001 by Basler Electric, Transformer Model 2010028 by Galaxy

More information

Operating Instructions. For. Alarm Control Module. Model SSR 500

Operating Instructions. For. Alarm Control Module. Model SSR 500 SSR 500 LEVEL CONTROL RELAY MODULE Operating Instructions For Alarm Control Module Model SSR 500 SSR Operation Instructions Rev. 1 Jan 01 Page 1/7 1. Note Please read and take note of these operating instructions

More information

SIMPLEX WEATHERPROOF CONTROL PANELS

SIMPLEX WEATHERPROOF CONTROL PANELS TECHNICAL BROCHURE BCP3 R10 FEATURES Rugged, NEMA 4X construction withstands even the most severe weather con ditions and prevents corrosion. Solid-state control board displays float status for ease of

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev Installation Guide for AL800UL-ADA NAC Power Extender Rev. 090500 Overview: The Altronix AL800UL-ADA is an extremely cost effective 8 amps voltage regulated remote power supply /battery charger. The AL800UL-ADA

More information

Variable Frequency Drive SERIES MP800 VFD

Variable Frequency Drive SERIES MP800 VFD Metron Fire Pump Controls and Accessories Variable Frequency Drive SERIES MP800 VFD Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for

More information

Life Alarm Multiplex Systems

Life Alarm Multiplex Systems Life Alarm Multiplex Systems UL, ULC Listed FM Approved Central Processing Unit 2120-8701 and -8702 Console-Mount FEATURES: l CPU and Accessory tems Housed in an Attractive, Freestanding Console l All

More information

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps. Issued 2006/08/01 Section 13920 Packaged Fire Pumps and Controllers Page 1 of 7 PART 1 GENERAL 1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1

More information

Instructions. Infiniti Gas Transmitter Model U Rev: 4/

Instructions. Infiniti Gas Transmitter Model U Rev: 4/ nstructions nfiniti Gas Transmitter Model U9500 Rev: 4/12 Table Of Contents APPLCATON.... 1 SETUP PROCEDURE... 20 FEATURES... 1 SPECFCATONS... 1 DESCRPTON... 3 MPORTANT SAFETY NOTES.... 4 NSTALLATON...

More information

Custom Duct Heaters. Special Applications

Custom Duct Heaters. Special Applications Special Applications Air Conditioning & Air Handling Units For more than 55 years, INDEECO has been supplying special heaters for use in air handling and air conditioning equipment (Figure 49). A wide

More information

SECTION LOW VOLTAGE LIGHTING CONTROLS

SECTION LOW VOLTAGE LIGHTING CONTROLS SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10 Belleville, Ontario Page 1 of 10 1 GENERAL 1.1 GENERAL REQUIREMENTS.1 The General Conditions of CCDC2-2008, and the General requirements of Division 1, form part of this Section and must read in conjunction

More information

Pioneer-R16 Gas Monitor Operator s Manual

Pioneer-R16 Gas Monitor Operator s Manual Pioneer-R16 Gas Monitor Operator s Manual Edition 7/2/97 RKI INSTRUMENTS, INC RKI Instruments, Inc. 33248 Central Ave, Union City, CA 94587 (510) 441-5656 Chapter 1: Description About the Pioneer-R16 Gas

More information

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE The Door Switch 11772 Westline Industrial Drive St. Louis, Mo 63146 (877) 998-5625 www.thedoorswitch.com Patent No. RE42,991 and RE44,039 CONTROL PANEL TRANSFORMER (SUPPLIED WITH CONTROL PANEL) NOTIFICATION

More information

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX: ACORN SAFETY P.O. BOX 3527 CITY OF INDUSTRY, CA 91744-0527 UNITED STATES OF AMERICA WWW.ACORNSAFETY.COM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS ELECTRIC ALARM WITH LIGHT AND HORN Models S0000-AL1

More information

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 031703 Overview: The Altronix AL802ULADA is an extremely cost effective 8 amp voltage regulated

More information

SETION EMERGENCY LIGHTING NATIONAL FIRE PROTECTION ASSOCIATION (NEPA) (2006) Life Safety Code, 2006 Edition

SETION EMERGENCY LIGHTING NATIONAL FIRE PROTECTION ASSOCIATION (NEPA) (2006) Life Safety Code, 2006 Edition SETION 16420 PART 1 - GENERAL 1.01 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation

More information

AL800ULADA. NAC Power Extender. Installation Guide

AL800ULADA. NAC Power Extender. Installation Guide AL800ULADA NAC Power Extender Installation Guide Rev. 122000 AL800ULADA - NAC Power Extender Overview: The Altronix AL800ULADA is an extremely cost effective 8 amp voltage regulated remote power supply/battery

More information

Micro-DCI 4 Channel Indicator Totalizers Series 53IT5100

Micro-DCI 4 Channel Indicator Totalizers Series 53IT5100 Micro-DCI 4 Channel Indicator Totalizers Series 53IT5100 Four Channels of Process Variable Bargraph Indication Four Channels of Integration and Digital Totalization An Alarm/Annunciator Summary Intuitive

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards Date Description of Change Pages / Sections Modified ID 6/15/16 Entire document - mgl44 PART 1 - INTRODUCTION 1.1 PURPOSE A. This section is intended to define the general installation and minimum product

More information

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL. Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL www.aquaticsentry.com TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 3 2. APPLICATION... 3 2.1 HIGH Liquid Level Alarm 2.2 LOW Liquid Level Alarm 3. INSTALLATION...

More information

Pump-Down Controller MODEL 4052

Pump-Down Controller MODEL 4052 Pump-Down Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4052 Pump-Down

More information

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM User Instructions For The Model 5200 Gas Monitor System To completely customize the specifications to your exact application, modifications to the following

More information

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU with Automatic Power Transfer Switch Contents: NOTE: The drawings included in this package are for controllers covered under our standard

More information

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014 January 16, 2014 Release Control Panel 290a 1. Description The Viking VFR400 is a microprocessor based releasing control panel for use on preaction, deluge, Surefire, Firecycle multicycle sprinkler systems,

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)

More information

bmckup circuilb bm viommd.

bmckup circuilb bm viommd. 604/654/1204/1254 1 Fiva smm LiohtN Oaufitlon~ pmvkk Conllnuouo systm moniladng. SVSTEM OFF 1. Steuly Goon-EntmncolExit dolay cinult open. 2. Puiming &an-main Saurity circuit opm, 3. Both Lights Off-Ail

More information

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm General Description & Applications The TCA-9102 Series Temperature Controller with Alarm offers a versatile solution for a

More information

Selectronic Tattletale Remote Alarm Annunciators

Selectronic Tattletale Remote Alarm Annunciators Selectronic Tattletale Remote Alarm Annunciators ST-95046B Revised 08-06 Catalog Section 25 ST Series Provide Audible and Visual Alarm Simple and Inexpensive Wide Range of Applications Gen-Set Models Meet

More information

LMR Electric Fire Pump Controllers Features

LMR Electric Fire Pump Controllers Features 1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller. The on/off switch, feed and reset buttons are front accessible. A bi-color status

More information

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM TTC-1 TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION The nvent RAYCHEM TraceTek TTC-1 sensing module is used with TraceTek sensing cables to detect liquid leaks.

More information

SECTION ROTARY-SCREW WATER CHILLERS

SECTION ROTARY-SCREW WATER CHILLERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Factory-assembled packaged chiller. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled water connections. E. Electrical power connections.

More information

Gate Operator. Modfications

Gate Operator. Modfications Gate Operator Modfications 100va Transformer G90 100 OP1 - Single Phase G90 100 OP3 -Three Phase Upgrades the transformer in the operator enclosure from 40va to 100va. Provides additional control circuit

More information

Drawing Submittal Package

Drawing Submittal Package Project: Customer: Engineer: Pump Manufacturer: Drawing Submittal Package Model GPL + GLU Limited Service Full Voltage Across the Line Start Electric Pump Controller with Automatic Power Transfer Switch

More information

I/O ZONE 560/583 AND OPERATION MANUAL

I/O ZONE 560/583 AND OPERATION MANUAL UPM I I/O ZONE 560/583 INSTALLATION AND OPERATION MANUAL 1 UNIT PROTECTION MODULE HARDWARE OPERATION IMPORTANT: This manual is for UPM board part numbers 8733 800 259. See controller label as shown in

More information

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

SOLID STATE SECURITIES, INC. THE SS90 SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL S S S S S S LISTED L * PATENT PENDING S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT U 99Y9 RESET RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION: RELEASE DEVICES MADE IN THE U.S.A. RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION: S/N: The "WPS" World Power Series, Time Delay Release

More information

ESP TECHNOLOGIES LIMITED

ESP TECHNOLOGIES LIMITED Alarm Technology ESPAN-01 Series Annunciator System Combination type User Manual (Rev. 1) ESP TECHNOLOGIES LIMITED www.esptechno.com Content Page Introduction 2 General Description 2 Overview - Annunciator

More information

ELP21LU3-LF-HLOL THREE CHANNEL

ELP21LU3-LF-HLOL THREE CHANNEL ELP21LU3-LF-HLOL THREE CHANNEL 516-467-5787 HI LEVEL LOW LEVEL LEAK DETECTION 11.00 TEST SYSTEM DETECTING HORN OFF 6.00 SPECIFICATIONS POWER INPUT 85-125 VAC, 47-440 Hz 16 Watts maximum POWER TO SENSORS

More information

Installation and Operating instructions

Installation and Operating instructions Technology servng manknd Installaton and Operatng nstructons ART Analog room thermostat wth day program for gas fred bolers r. 8610015 Wolf GmbH Postfach 1380 84048 Manburg Tel. +49 8751/74-0 Fax +49 8751/741600

More information

Construction Electrical

Construction Electrical INDEECO offers a broad range of electrical components for temperature, safety, and power control. For most applications, the Control Option system, described in the previous section, makes it easy to specify

More information

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature AutoTest VSR (VSR-AT) (EU) Features Assembled in USA 0-30 second field replaceable electronic retard Two SPDT (Form C) switch contacts Weatherproof Easy to read wire terminal designations Easy to read

More information

CONDENSATE MANAGEMENT SYSTEMS

CONDENSATE MANAGEMENT SYSTEMS CONDENSATE MANAGEMENT SYSTEMS AG-1100+ Magnetic Float Switch System for Metal Secondary Drain Pans The AG-1100+ is incredibly easy to install. It can be mounted to the drain pan in 10 seconds or less.

More information