Size: px
Start display at page:

Download ""

Transcription

1

2

3

4

5

6

7

8 I.C. Thomasson Associates, Inc. CONSULTING ENGINEERS 2950 KRAFT DRIVE, SUITE 500 NASHVILLE, TN PHONE (615) FAX (615) ICT PROJECT # HODGSON DOUGLAS landscape architecture planning. urban design th Ave. South, Nashville, Tennessee t f SYMBOL L L F SD DSD HD SD E FSD DH TS FS AFF AFG ABV ABC CLG EWC EM EX RW FBO GND R UON WH WP DESCRIPTION CHIME/FLASHING LIGHT COMBINATION MANUAL PULL STATION SMOKE DETECTOR DUCT-SMOKE DETECTOR (DAMPER) OR (EXHAUST) AUTOMATIC HEAT DETECTOR (RATE OF RISE TYPE) SYSTEM CONNECTED SMOKE DETECTOR FOR FIREMAN'S RECALL FIRE SMOKE DAMPER SMOKE DOOR HOLDER TAMPER SWITCH FLOW SWITCH L FLASHING LIGHT/HORN SIGNAL STATION 80" FS FACP FAA FLASHING LIGHT SPEAKER SIGNAL STATION CONTROL PANEL REMOTE ANNUNCIATOR 80" DC DOOR CONTACTOR RGA CR EDS MDL RMD RPB PE AV TV EPO KP IC A ARA ABOVE FINISHED FLOOR ABOVE FINISHED GRADE MOUNT ABOVE COUNTER ABOVE CEILING CEILING ELECTRIC WATER COOLER EMERGENCY EXISTING ROOM WIZARD FURNISHED BY OTHERS, INSTALLED BY ELECTRICAL CONTRACTOR GROUND RELOCATED UNLESS OTHERWISE NOTED WATER HEATER WEATHER PROOF, NEMA 3R SYMBOLS GENERAL NOTES: FIRE ALARM SYSTEM A. ALL MOUNTING HEIGHTS GIVEN IN THE LEGEND, SCHEDULES, PLANS, AND DRAWING NOTES ARE TO THE CENTERLINE OF THE DEVICE, UNLESS OTHERWISE NOTED. B. INSTALL ALL SWITCHES AT A CENTERLINE HEIGHT OF A.F.F. UNLESS OTHERWISE NOTED. WHERE SWITCHES OR RECEPTACLES ARE MOUNTED ABOVE CASEWORK OR MILLWORK, LOCATE AT A HEIGHT OF 3'-8" MAX. ABOVE FINISH FLOOR OR 3" ABOVE BACKSPLASH TO CENTERLINE. C. SEE ARCHITECTURAL MOUNTING HEIGHTS. D. ADDITIONAL SYMBOLS MAY BE SHOWN OR DENOTED ON OTHER SHEETS. E. ALL SYMBOLS, NOTES, AND ABBREVIATIONS SHOWN ON THE LEGEND ARE NOT NECESSARILY USED IN THIS SET OF CONTRACT DOCUMENTS. F. NUMERICAL SUBSCRIPT ADJACENT TO DEVICE FIXTURE, EQUIPMENT OR JUNCTION BOX SYMBOL ON THE DRAWINGS DENOTES THE PANELBOARD CIRCUIT NUMBER TO WHICH DEVICE, FIXTURE, EQUIPMENT OR WIRING IN JUNCTION BOX IS CONNECTED. MOUNTING HT TO CENTERLINE UNO FLASHING LIGHT 80" REMOTE GENERATOR ANNUNCIATOR CARD READER ELECTRIC DOOR STRIKE MAGNETIC DOOR STRIKE REQUEST TO EXIT MOTION DETECTOR REQUEST TO EXIT PUSH DETECTOR DATA DUPLEX ABOVE COUNTER DATA DUPLEX WIRELESS ACCESS POINT TELEPHONE OUTLET TELEPHONE DATA OUTLET PHOTOCELL AUDIO/VISUAL CONNECTION TV EMERGENCY POWER OFF SWITCH KEYPAD AREA OF REFUGE INTERCOM AREA OF REFUGE HEADEND Lighting Fixture Schedule MISCELLANEOUS ABBREVIATIONS Type Manufacturer Model Lamp Description 1 LITHONIA DMW2-L LM-AFL-WD-120-GZ1-35K-80CRI 40W LED STRIP FIXTURE FASTENED TO STRUCTURE 80" CEILING CEILING 6'-0" CEILING M ELECTRICAL LEGEND SYMBOL DESCRIPTION EBP "5" 3 SV PS R T J PB PP S S 2 3R 3R S 3 S 4 S D S M S OC S 3D S T S TWP S TP S LV ELC S WP J J J HH MH PP J PDM OC E TV E GFI AV AV AV BPI AFM SR USB IG IG IG WP CONDUIT CONCEALED IN WALL OR CEILING. CONDUIT CONCEALED IN FLOOR CONDUIT EXPOSED ON WALL OR CEILING. HOMERUN CONDUIT CONDUIT TURNING UP CONDUIT TURNING DOWN SURFACE MOUNTED LIGHT FIXTURE ON NORMAL BRANCH CIRCUIT SURFACE MOUNTED FIXTURE ON EMERGENCY BRANCH CIRCUIT SURFACE MOUNTED FIXTURE ON CRITICAL BRANCH CIRCUIT RECESSED LIGHT FIXTURE ON NORMAL BRANCH CIRCUIT RECESSED LIGHT FIXTURE ON EMERGENCY BRANCH CIRCUIT SURFACE MOUNTED WALL LIGHT FIXTURE ON NORMAL BRANCH CIRCUIT SURFACE MOUNTED WALL LIGHT FIXTURE ON EMERGENCY BRANCH CIRCUIT SURFACE MOUNTED WALL LIGHT FIXTURE ON CRITICAL BRANCH CIRCUIT RECESSED WALL LIGHT FIXTURE ON NORMAL BRANCH CIRCUIT RECESSED MOUNTED WALL LIGHT FIXTURE ON EMERGENCY BRANCH CIRCUIT RECESSED MOUNTED WALL LIGHT FIXTURE ON CRITICAL BRANCH CIRCUIT SURFACE/SUSPENDED MOUNTED LIGHT FIXTURE ON NORMAL BRANCH CIRCUIT SURFACE/SUSPENDED MOUNTED LIGHT FIXTURE ON EMERGENCY BRANCH CIRCUIT SURFACE/SUSPENDED MOUNTED LIGHT FIXTURE ON CRITICAL BRANCH CIRCUIT RECESSED LIGHT FIXTURE ON NORMAL BRANCH CIRCUIT RECESSED LIGHT FIXTURE ON EMERGENCY BRANCH CIRCUIT RECESSED LIGHT FIXTURE ON CRITICAL BRANCH CIRCUIT EXIT LIGHT, CEILING MOUNTED EXIT LIGHT, WALL MOUNTED TWO HEAD BATTERY POWERED EMERGENCY EGRESS LIGHT REMOTE EMERGENCY BATTERY PACK LIGHTING FIXTURE TYPE DESIGNATION-SEE LIGHTING FIXTURE SCHEDULE AREA OR STREET LIGHT FIXTURE AREA OR STREET LIGHT FIXTURE DISCONNECT SWITCH, NON-FUSIBLE DISCONNECT SWITCH, FUSIBLE DISCONNECT SWITCH, NON-FUSIBLE RT DENOTES NEMA-3R DISCONNECT SWITCH, FUSIBLE RT DENOTES NEMA-3R MOTOR CONNECTION WITH APPROXIMATE HORSE-POWER SHOWN SOLENOID VALVE PRESSURE SWITCH RELAY TRANSFORMER JUNCTION BOX - NOT WALL MOUNTED JUNCTION BOX - WALL MOUNTED PUSH BUTTON HAND HOLE MAN HOLE ENCLOSED CIRCUIT BREAKER POWER POLE CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR SINGLE POLE SWITCH-(WHITE) TWO POLE SWITCH-(WHITE) THREE-WAY SWITCH-(WHITE) FOUR WAY SWITCH-(WHITE) SINGLE POLE DIMMER SWITCH WALL MOUNTED OCCUPANCY SENSOR SWITCH (WHITE) THREE-WAY DIMMER SWITCH THERMAL MOTOR SWITCH-(FBE) THERMAL MOTOR SWITCH, WEATHERPROOF-(FBE) THERMAL MOTOR SWITCH, WITH PILOT LIGHT (FBE) LOW VOLTAGE SWITCH POWER PACK EMERGENCY LIGHTING CONTROLLER - FUNCTIONAL DEVICES ESRB SINGLE POLE SWITCH, WEATHERPROOF 20A 120V. DUPLEX RECEPTACLE 20A 120V. DUPLEX RECEPTACLE ABOVE COUNTER 20A 120V. DUPLEX RECEPTACLE ABOVE COUNTER ON EMERGENCY BRANCH CIRCUIT (RED) 20A 120V. DUPLEX RECEPTACLE FOR TV POWER 6" TO CENTERLINE BELOW FINISH CEILING 20A 120V. QUADRAPLEX RECEPTACLE SINGLE RECEPTACLE, AMPERAGE, VOLTAGE, NEMA CONFIGURATION AS REQUIRED BY EQUIP. SUPPLIER OR AS NOTED 20A 120V. QUADRAPLEX RECEPTACLE ABOVE COUNTER 20A 120V. QUADRAPLEX RECEPTACLE ABOVE COUNTER ON EMERGENCY BRANCH CIRCUIT 20A GROUND FAULT TYPE RECEPTACLE 20A GROUND FAULT RECEPTACLE WEATHERPROOF TWO GANG WITH ONE DUPLEX RECEPTACLE AND ONE DATA OUTLET TWO GANG WITH ONE QUAD 20A RECEPTACLE AND ONE DATA OUTLET TWO GANG WITH ONE HARD CONNECTION 20A RECEPTACLE, & ONE DATA OUTLET THREE GANG WITH TWO DUPLEX 20A RECEPTACLES, & ONE TELEPHONE OUTLET THREE GANG WITH ONE QUAD 20A RECEPTACLE AND ONE DATA OUTLET AND ONE AV CONNECTION THREE GANG WITH ONE DUPLEX 20A RECEPTACLE AND ONE DATA OUTLET AND ONE AV CONNECTION THREE GANG WITH ONE HARDWARE CONNECTION AND ONE DATA OUTLET AND ONE AV CONNECTION WALL MOUNTED FURNITURE BASE POWER FEED POWER DISTRIBUTION MODULE ACCESS FLOOR MODULE 20A DUPLEX RECEPTACLE AND SINGLE POLE SWITCH UNDER COMMON PLATE 20A 120V. DUPLEX USB TYPE 20A DUPLEX RECEPTACLE, ISOLATED GROUNDING, 20A DUPLEX RECEPTACLE, ISOLATED GROUNDING, INSTALL ABOVE COUNTER 20A QUADRAPLEX RECEPTACLE, ISOLATED GROUNDING 20A WEATHERPROOF DUPLEX RECEPTACLE 120V DUPLEX RECEPTACLE, CEILING MOUNTED WITH (1) SINGLE RECEPTACLE - AMPERAGE, VOLTAGE, NEMA CONFIGURATION AS REQUIRED BY EQUIP. SUPPLIER OR AS NOTED WITH (1) DUPLEX RECEPTACLE WITH (1) QUADRUPLEX RECEPTACLE WIREMOLD #3000 WITH HUBBELL 5352 DUPLEX 20A RECEPTACLES 24" ON CENTER PLUGMOLD #2000 WITH 20A DUPLEX RECEPTACLES 24" ON CENTER PUSHPAD FOR AUTOMATIC DOORS (F.B.O.) MOUNTING HEIGHT TO CENTERLINE UON AS NOTED CEILING NO. Date Issues/Revisions STAMP PROJECT NAME PRESERVATION PARK AMPHITHEATER Stage Thompson's Station, Tennessee PROJECT NO.: DRAWN BY: CHECKED BY: DRAWING TITLE ELECTRICAL LEGEND AND SCHEDULES DATE: April Dec. 2, 01, SCALE: DRAWING NUMBER E0.01

9 I.C. Thomasson Associates, Inc. CONSULTING ENGINEERS 2950 KRAFT DRIVE, SUITE 500 NASHVILLE, TN PHONE (615) FAX (615) ICT PROJECT # HODGSON DOUGLAS landscape architecture planning. urban design th Ave. South, Nashville, Tennessee t f Branch Panel: P1 Location: Exterior Volts: 120/240 Single A.I.C. Rating: Supply From: Utility Transformer Phases: 1 Mains Type: MCB Mounting: Surface Wires: 3 Mains Rating: 60 A Enclosure: Type 3R MCB Rating: 60 A Notes: UTILITY TRANSFORMER N Demand A B Demand CKT Circuit Description Code TRIP P P TRIP Code Circuit Description CKT 1 Lighting Lighting 20 A A Recepta... Receptacle 2 3 Receptacle Recepta A A Lighting Lighting 4 5 Receptacle Recepta A A Recepta... Receptacle 6 7 Spare A A -- Spare 8 9 Spare A A -- Spare Spare A A -- Spare Spare A A -- Spare Spare A A -- Spare Spare A A -- Spare Spare A A -- Spare Spare A A -- Spare Spare A A -- Spare Spare A A -- Spare Spare A A -- Spare Spare A A -- Spare 30 Total Load: 694 VA 494 VA Total Amps: 6 A 4 A Legend: GROUNDED SERVICE CONDUCTOR (SIZE PER NEC TABLE AND 12-1/2% RULE) GROUNDING ELECTRODE CONDUCTOR (SIZE PER NEC TABLE ) N G SERVICE ENTRANCE BREAKER MAIN BONDING JUMPER (SIZE PER NEC TABLE AND 12-1/2% RULE) Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Lighting 480 VA % 480 VA Receptacle 720 VA % 720 VA Total Conn. Load: 1186 VA Total Est. Demand: 1186 VA Total Conn. Current: 5 A Total Est. Demand Current: 5 A Notes: SERVICE ENTRANCE RATED Branch Panel: P2 Location: Exterior Volts: 120/240 Single A.I.C. Rating: Supply From: Utility Transformer Phases: 1 Mains Type: MCB Mounting: Surface Wires: 3 Mains Rating: 60 A Enclosure: Type 3R MCB Rating: 60 A SERVICE ENTRANCE GROUNDING DETAIL No Scale WATER PIPE, BUILDING STEEL & GROUND LOOP TO LOAD EQUIPMENT GROUNDING CONDUCTOR (SIZE PER NEC TABLE ) 2 NO. Date Issues/Revisions Notes: Demand A B Demand CKT Circuit Description Code TRIP P P TRIP Code Circuit Description CKT 1 Lighting Lighting 20 A A Recepta... Receptacle 2 3 Receptacle Recepta A A Lighting Lighting 4 5 Receptacle Recepta A A Recepta... Receptacle 6 7 Receptacle Recepta A A Recepta... Receptacle 8 9 Spare A A -- Spare Spare A A -- Spare Spare A A -- Spare Spare A A -- Spare Spare A A -- Spare Spare A A -- Spare Spare A A -- Spare Spare A A -- Spare Spare A A -- Spare Spare A A -- Spare Spare A A -- Spare 30 Total Load: 1007 VA 694 VA Total Amps: 8 A 6 A Legend: Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Lighting 640 VA % 640 VA Receptacle 1080 VA % 1080 VA Total Conn. Load: 1700 VA Total Est. Demand: 1700 VA Total Conn. Current: 7 A Total Est. Demand Current: 7 A UTILITY TRANSFORMER P1 60A 120/240 1 PHASE NEMA 3R UTILITY TRANSFORMER P2 60A 120/240 1 PHASE NEMA 3R STAMP PROJECT NAME PRESERVATION PARK AMPHITHEATER Thompson's Station, Tennessee Notes: SERVICE ENTRANCE RATED 3#4,#8GND,1"C. 3#4,#8GND,1"C. Stage ELECTRICAL RISER DIAGRAM N.T.S. PROJECT NO.: DRAWN BY: CHECKED BY: DRAWING TITLE ELECTRICAL DETAILS DATE: April Dec. 2, 01, SCALE: DRAWING NUMBER E1.01

10 36'' I.C. Thomasson Associates, Inc. CONSULTING ENGINEERS 2950 KRAFT DRIVE, SUITE 500 NASHVILLE, TN PHONE (615) FAX (615) ICT PROJECT # HODGSON DOUGLAS landscape architecture planning. urban design th Ave. South, Nashville, Tennessee t f '' 28'' 20'' 50'' OAK 54'' OAK SHED TRANFORMER BY MTEMC AND THOMPSON STATION NEW 60A 240V 2P, 3W, 3R SERVICE ENTRANCE PANELBOARD 'P2' T (1) 2" CONDUIT BY MTEMC AND THOMPSON'S STATION. GENERAL NOTES: A. THE EXISTING UTILITY LOCATIONS ARE SHOWN FOR GENERAL INFORMATION ONLY AND ARE NOT GUARANTEED TO BE EITHER ACCURATE OR ALL INCLUSIVE. PRIOR TO EXCAVATION IN ANY AREA, OBTAIN THE AID OF ALL UTILITY OWNERS TO IDENTIFY AND LOCATE THEIR RESPECTIVE FACILITIES. ANY UTILITY DAMAGE CAUSED BY THE CONSTRUCTION ACTIVITIES SHALL BE REPAIRED OR REPLACED AT NO EXPENSE TO THE OWNER. B. EXISTING UTILITIES, WHICH ARE NOT SHOWN, THAT ARE DISCOVERED DURING EXCAVATION SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVES FOR PROPER COORDINATION. REMOVE, REWORK AND/OR REROUTE THE EXISTING UTILITIES, AS DIRECTED BY THE OWNER'S REPRESENTATIVES. C. FULLY COORDINATE ALL REQUIREMENTS WITH MIDDLE TENNESSEE ELECTRIC MEMBERSHIP CORPORATION (MTEMC). NO. Date Issues/Revisions D. REFERENCE MTEMC GUIDELINES FOR ADDITIONAL DETAILS. TRANFORMER BY MTEMC AND THOMPSON STATION NEW 60A 240V 2P, 3W, 3R SERVICE ENTRANCE PANELBOARD 'P1' T (1) 2" CONDUIT BY MTEMC AND THOMPSON'S STATION. STAMP (1) 2" CONDUIT BY MTEMC AND THOMPSON'S STATION. TRANSFORMER BY MTEMC AND THOMPSON'S STATION T (1) 2" CONDUIT BY MTEMC AND THOMPSON'S STATION. PROJECT NAME PRESERVATION PARK AMPHITHEATER Thompson's Station, Tennessee Stage 100% CHECKSET PROJECT NO.: DRAWN BY: CHECKED BY: DRAWING TITLE ELECTRICAL - SITE PLAN 1 SITE PLAN ES.01 1" = 50'-0" DATE: April Dec. 2, 22, 01, SCALE: DRAWING NUMBER ES.01

11 I.C. Thomasson Associates, Inc. CONSULTING ENGINEERS 2950 KRAFT DRIVE, SUITE 500 NASHVILLE, TN PHONE (615) FAX (615) ICT PROJECT # HODGSON DOUGLAS landscape architecture planning. urban design th Ave. South, Nashville, Tennessee t f P2-7 P1-3 P1-2 P2-8 P1-6 WP P1 P1-1 P1-4 WP P1-5 P2-3 WP P2-1 P2 P2-2 NO. Date Issues/Revisions P2-6 WP P2-5 STAMP P2-4 2 ENLARGED SITE PLAN A ES.02 3/64" = 1'-0" 1 ENLARGED SITE PLAN B ES.02 3/64" = 1'-0" PROJECT NAME PRESERVATION PARK AMPHITHEATER Thompson's Station, Tennessee Stage PROJECT NO.: DRAWN BY: CHECKED BY: DRAWING TITLE ELECTRICAL - ENGLARGED PLANS DATE: April Dec. 2, 01, SCALE: DRAWING NUMBER ES.02

FIRE ALARM: BY OTHERS, IF REQUIRED.

FIRE ALARM: BY OTHERS, IF REQUIRED. x x x x x x OS LIGHTING S FLUORESCENT LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. CAPITAL LETTER DENOTES TYPE, LOWER CASE LETTER DENOTES SWITCH LEG. FLUORESCENT STRIP LIGHT FIXTURE,

More information

FIRE ALARM: BY OTHERS, IF REQUIRED.

FIRE ALARM: BY OTHERS, IF REQUIRED. x x x x x x OS LIGHTING S FLUORESCENT LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. FLUORESCENT STRIP LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. WALL BRACKET FLUORESCENT

More information

SINGLE CONVENIENCE OUTLET, WALL MOUNTED RECESSED +18" AFF

SINGLE CONVENIENCE OUTLET, WALL MOUNTED RECESSED +18 AFF LUORESCENT STRIP SURACE/PENDANT MOUNTED ' X ' LUORESCENT RECESS MOUNTED LUORESCENT STRIP RECESS MOUNTED LUORESCENT STRIP WALL MOUNTED LUORESCENT STRIP RECESS MOUNTED LUORESCENT EMERGENCY STRIP SURACE/PENDANT

More information

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings 1 T Consultant: NOTES, SYMBOLS & ABBREVIATIONS - MECHANICAL Number Description M001 Vestibule 117 LAN/IT Coffee 115 116 Mail Room 118 114 113 112 Scanning 119 Open Office 101 FIRST FLOOR PLAN - MECHANICAL

More information

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL 3300 SUMMIT BOULEVARD WEST PALM BEACH, FLORIDA 33406 TEL (561) 688-7687 FAX (561) 688-7654 http://www.palmbeach.k12.fl.us/fm/bd/index.htm

More information

Ho-Chunk Gaming THUNDERBIRD ENGINEERING, INC. MILWAUKEE: (414) MADISON: (608)

Ho-Chunk Gaming THUNDERBIRD ENGINEERING, INC. MILWAUKEE: (414) MADISON: (608) Ho-Chunk Gaming POWER SYMBOLS X ELECTRICAL PANEL - REFER TO DRAWINGS FOR WIDTH AND PANEL SCHEDULES PANEL NAMING: XXP-#X: DENOTES PANEL FUNCTION: L = LIGHTING P = GENERAL POWER E = EMERGENCY S = OPTIONAL

More information

ELECTRICAL SYMBOLS AND ABBREVIATIONS NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED

ELECTRICAL SYMBOLS AND ABBREVIATIONS NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED SYMBOLS AND ABBREVIATIONS ABBREVIATIONS GENERAL NOTES LINE TYPE LEGEND CIRCUITS TELECOMMUNICATION SYSTEM ING EQUIPMENT POWER DEVICES FIRE ALARM SYSTEM NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED

More information

Leviton Combination Switch And Tamper Resistant Outlet Wiring Diagram

Leviton Combination Switch And Tamper Resistant Outlet Wiring Diagram Leviton Combination Switch And Tamper Resistant Outlet Wiring Diagram Leviton SmartLockPro 15 Amp Tamper-Resistant Combination GFCI Duplex Outlet and Switch - White-R02-X7299-00W - The Home Depot. From

More information

GARCIA GALUSKA DESOUSA Consulting Engineers

GARCIA GALUSKA DESOUSA Consulting Engineers L#57297 /Page 1/July 21, 2017 ELECTRICAL SYSTEMS NARRATIVE REPORT The following is the Electrical Systems narrative, which defines the scope of work and capacities of the Power and Lighting systems, as

More information

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used

More information

CT CABINET AND UTILITY METERING WELL AND BOOSTER PUMP CONTROL 12"x12" WIREWAY 200A MCB 200A, 120/208V, 3Ø, 4W BOARD TVSS CIA ALARM 400A, DOUBLE-THROW SWITCH PORTABLE GENERATOR CONNECTION ENCLOSURE EXISTING

More information

SECTION LIGHTING CONTROLS

SECTION LIGHTING CONTROLS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 09 23 LIGHTING CONTROLS SPEC WRITER NOTE: 1. Delete between //----// if not applicable to project. Also, delete any other item or paragraph not applicable to

More information

The following information shall become and form part of the contract documents.

The following information shall become and form part of the contract documents. October 4, 206 To: Attention: Re: All Bidders All Bidders JCBE Gymnasium HVAC Upgrades BC#: 206433 Edmonds Project No.: BHM6090 All bidders, The following information shall become and form part of the

More information

PROJECT NO. CWA SEPTEMBER 24, 2014 ADDENDUM NO. 6 BESSEMER RECREATION & WELLNESS CENTER

PROJECT NO. CWA SEPTEMBER 24, 2014 ADDENDUM NO. 6 BESSEMER RECREATION & WELLNESS CENTER PROJECT NO. CWA 2013-04 SEPTEMBER 24, 2014 ADDENDUM NO. 6 BESSEMER RECREATION & WELLNESS CENTER BIDS RECEIVED: CITY HALL, CITY OF BESSEMER TIME: 2:00pm DATE: October 2, 2014 City of Bessemer --------------------------------------------------------------------------------------------------------------------------------------------

More information

UBC Technical Guidelines Section Edition Access Control Page 1 of 5

UBC Technical Guidelines Section Edition Access Control Page 1 of 5 Page 1 of 5 1.0 GENERAL 1.1 Related UBC Guidelines.1 Section 28 05 00 Access Services: General Standards.2 Section 08 71 00 Door Hardware 1.2 Coordination Requirements.1 UBC Access Services 1.3 Description.1

More information

LIGHT LEVEL REQUIREMENTS MINIMUM ACCEPTABLE FOOT CANDLES

LIGHT LEVEL REQUIREMENTS MINIMUM ACCEPTABLE FOOT CANDLES LIGHT LEVEL REQUIREMENTS LOCATION Classrooms and instrumental areas- Study Halls, Lecture Rooms, Art Rooms, Offices, Libraries, Conference Rooms, Work Rooms, Shops, Laboratories and Secondary School Cafeterias.

More information

ELECTRICAL SYSTEMS ASSESSMENT Hanover High School

ELECTRICAL SYSTEMS ASSESSMENT Hanover High School ELECTRICAL SYSTEMS ASSESSMENT Hanover High School ELECTRICAL DISTRIBUTION SYSTEM:?? The existing electrical service consists of an underground primary service originating at a utility pole on Cedar Street,

More information

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings. DIVISION 26 ELECTRICAL SECTION 26 27 26 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings. B. Specialty switches and outlets

More information

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM SECTION 283111 - DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Renovate MCRC Facilities Great Lakes, IL

Renovate MCRC Facilities Great Lakes, IL 6. ENGINEERING SYSTEMS REQUIREMENTS D50 ELECTRICAL SYSTEM DESCRIPTION The electrical repair work includes the design and construction of the electrical distribution system for the B3200 Marine Corps Reserve

More information

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10 Belleville, Ontario Page 1 of 10 1 GENERAL 1.1 GENERAL REQUIREMENTS.1 The General Conditions of CCDC2-2008, and the General requirements of Division 1, form part of this Section and must read in conjunction

More information

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2 Division 28 ELECTRONIC SAFETY AND SECURITY TABLE OF CONTENTS 28 0000 GENERAL... 2 A. DEFINITIONS...2 28 3111 DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2 A. DESIGN REQUIREMENTS...2 B. CONSTRUCTION REQUIREMENTS...2

More information

Library stacks and records storage 150 LB/SF live load

Library stacks and records storage 150 LB/SF live load SPACE TYPE: LIBRARY Construction Criteria The unit costs for Library space types are based on the construction quality and design features in the following table. This information has been generally organized

More information

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority. Fitness Facility Addition Page 1 1.1 CODES AND STANDARDS.1 Do complete installation in accordance with the latest edition of the CSA C22.1 as amended by the latest editions of the National Building Code

More information

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices. SECTION 16470 PANELBOARDS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 09900 - Painting. 2. 16120 - Wire and Cable. 3. 16475 - Overcurrent Protective Devices. 1.02 SYSTEM DESCRIPTION A. Performance

More information

SECTION LOW VOLTAGE LIGHTING CONTROLS

SECTION LOW VOLTAGE LIGHTING CONTROLS SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

Electrical System (N) PANELBOARD "L1" VOLTAGE: 208/120 A, 3P :MAIN C/B PHASE: 3 A :BUSSING WIRE: 4 :MOUNTING

Electrical System (N) PANELBOARD L1 VOLTAGE: 208/120 A, 3P :MAIN C/B PHASE: 3 A :BUSSING WIRE: 4 :MOUNTING Electrical System After re-designing the lighting system for the children s computer, circulation and storytelling areas, the electrical system had to be redesigned as well. These are the new panel board

More information

CHAPTER 20 SERVICE EQUIPMENT

CHAPTER 20 SERVICE EQUIPMENT SERVICE EQUIPMENT CHAPTER 20 SERVICE EQUIPMENT Service equipment includes service cabinets and the equipment and materials necessary for installation. 20.1 Signal Service Cabinet For MnDOT traffic control

More information

HMC ARCHITECTS 2495 Natomas Park Drive, Studio 100 Sacramento, California ADDENDUM NO. 3

HMC ARCHITECTS 2495 Natomas Park Drive, Studio 100 Sacramento, California ADDENDUM NO. 3 HMC ARCHITECTS 2495 Natomas Park Drive, Studio 100 Sacramento, California 95833 September 15, 2016 Woodland Joint Unified School District Spring Lake Area Elementary School HMC No. 3535003.000 DSA Appl.

More information

PHOTOS. December 8, 2017

PHOTOS. December 8, 2017 PHOTOS City of Santa Monica Camera Obscura Exterior Lighting Upgrades 1450 Ocean Avenue Santa Monica, CA 90401 December 8, 2017 Kitchell CEM Camera Obscura Building Exterior Lighting Upgrades December

More information

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F II 1400-2 ACSI 1406-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F INSTALLATION Transformer Model BE31763001 by Basler Electric, Transformer Model 2010028 by Galaxy

More information

DEMOLITION GENERAL NOTES As-built conditions have been determined from Record Drawings (if they exist), field investigations (accessible areas and

DEMOLITION GENERAL NOTES As-built conditions have been determined from Record Drawings (if they exist), field investigations (accessible areas and DEMOLITION GENERAL NOTES As-built conditions have been determined from Record Drawings (if they exist), field investigations (accessible areas and equipment), and discussions with maintenance personnel

More information

A. This Section includes the following lighting control devices:

A. This Section includes the following lighting control devices: Attachment G LIGHTING CONTROL SPECIFICATIONS (Download Document separately) LIGHTING CONTROL SPECIFICATIONS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including

More information

F. GENERAL REQUIREMENTS Electrical Design Criteria 2006 Edition 4/3/06 School District Palm Beach County Page-1 of 15

F. GENERAL REQUIREMENTS Electrical Design Criteria 2006 Edition 4/3/06 School District Palm Beach County Page-1 of 15 ELECTRICAL DESIGN CRITERIA TABLE OF CONTENTS I GENERAL...2 II CRITERIA...2 A. POWER DISTRIBUTION SYSTEMS...2 1. NORMAL POWER:...2 2. EMERGENCY POWER...3 B. LIGHTING...4 1. GENERAL...4 2. AVERAGE MAINTAINED

More information

Electrical Design Guidelines Table of Contents

Electrical Design Guidelines Table of Contents C: Compliant Rev. 3 Dated June 13 11 NC: Non-Compliant NA: Not Applicable Page1 16.1 General 16.2 Single Line Diagrams 16.3 Electric Motor Equipment and Controls 16.4 Lighting 16.5 Emergency Lighting 16.6

More information

The following narrative outlines a conceptual electrical Scope of Work for converting the Phase 2 TRW Building to an Exhibition Hall.

The following narrative outlines a conceptual electrical Scope of Work for converting the Phase 2 TRW Building to an Exhibition Hall. The following narrative outlines a conceptual electrical Scope of Work for converting the Phase 2 TRW Building to an Exhibition Hall. Demolition: The area of work shall be a complete gut ; removing all

More information

Building Electrical System Overview

Building Electrical System Overview Philip Mackey L/E Dr. Mistrick Holy Cross Hospital North Addition Silver Spring, MD 0/3/05 Building Electrical System Overview Executive Summary: The following report describes the existing emergency power

More information

SECTION LIGHTING CONTROL DEVICES

SECTION LIGHTING CONTROL DEVICES SECTION 16145 LIGHTING CONTROL DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods 1. BASIC ELECTRICAL MATERIALS 1. All conduit and raceway must be 3/4" or larger. Exposed raceway in finished areas shall be in 700 or larger wiremold. Exception: runs to individual devices 10 or less,

More information

L04 X01 X03 X01 R21A R21A F09 L27 R18 R16A R18 R21A KING 107 F09 F09 L27 D03A Z-38 KING 109 R21A R18 R16A R18 R21A F09 F09 X03 L27 F09 R21A R18 R18

L04 X01 X03 X01 R21A R21A F09 L27 R18 R16A R18 R21A KING 107 F09 F09 L27 D03A Z-38 KING 109 R21A R18 R16A R18 R21A F09 F09 X03 L27 F09 R21A R18 R18 REFERENCE NOTES A. SEE 0 SERIES DRAWINGS FOR CEILING & LIGHTING IN GUESTROOMS. B. SEE 00 SERIES DRAWINGS FOR CEILING & LIGHTING INFORMATION & DETAILS IN PUBLIC SPACE. C. PROVIDE EMERGENCY LIGHTING AND

More information

SOUTHVIEW MEDICAL CENTER

SOUTHVIEW MEDICAL CENTER PROJECT TITLE: SOUTHVIEW MEDICAL CENTER ENTRANCE VESTIBULE 1997 Miamisburg Centerville Rd. Dayton, Ohio DRAWING INDEX: STRUCTURAL ARCHITECTURAL JUNE 26, 2014 Bulletin #1 - September 12, 2014 AREA OF WORK

More information

Element D Services Electrical

Element D Services Electrical PART 1 - GENERAL 1.01 OVERVIEW A. This Section includes design standards and requirements for electrical service and distribution. This is a design standard and is not intended to be used as a Specification.

More information

POWER SOURCES MODEL NO. DESCRIPTION PRICE

POWER SOURCES MODEL NO. DESCRIPTION PRICE POWER SOURCES BE-961-1 BE-961-2 BE-961-5 BE-961-6 Battery Eliminator - 120VAC to 9VDC Includes 10 Flex Conduit and Transformer Powers up to 3 ECLs or 3 EBs Battery Eliminator - Same as above with Supervisory

More information

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics. A28.1 Standard of Practice - Fire Alarm Systems NOTE: Significant revisions or additions to the previous standards are highlighted in italics. OBJECTIVE OF STANDARD To provide compliant smart addressable

More information

A. This Section includes the following lighting control devices:

A. This Section includes the following lighting control devices: SECTION 26 09 23 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 This section specifies the furnishing, complete installation, and connection of automatic transfer switches. 1.2 RELATED WORK A. Section 14 21 00, ELECTRIC

More information

Brighton Area Fire Authority

Brighton Area Fire Authority 615 W. Grand River Ave. Brighton, MI 48116 o: 810-229-6640 f: 810-229-1619 January 14, 2019 Fire Alarm Contractors RE: Fire Alarm Credential & Submittal Requirements To Whom It May Concern: The following

More information

SECTION (16140) - WIRING DEVICES

SECTION (16140) - WIRING DEVICES SECTION 26 27 26 (16140) - WIRING DEVICES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Receptacles, Connectors, Switches, and Finish Plates. B. Related Sections: 1. Section 00 31 13.43 (00370) -

More information

Lindsay Frederick. Lighting + Electrical. Ron Dodson Faculty Advisor. Native American Cultural Center Arizona. Technical Report 2

Lindsay Frederick. Lighting + Electrical. Ron Dodson Faculty Advisor. Native American Cultural Center Arizona. Technical Report 2 Lindsay Frederick Lighting + Electrical Ron Dodson Faculty Advisor Native American Cultural Center Arizona Technical Report 2 Native American Cultural Center Technical Report 2 p. 2 Executive Summary The

More information

Port of Portland Conveying Equipment Guidelines

Port of Portland Conveying Equipment Guidelines Role: Consultant for the Port Design Guidelines Port of Portland Conveying Equipment Guidelines ELEVATOR, ESCALATOR, AND MOVING WALK DESIGN OVERVIEW The Division 14 specification sections include appropriate

More information

Memphis Housing Authority High Rise Fire Alarm Upgrades. Questions from Contractors (Through Addendum #2) Communications Systems, Inc.

Memphis Housing Authority High Rise Fire Alarm Upgrades. Questions from Contractors (Through Addendum #2) Communications Systems, Inc. Memphis Housing Authority High Rise Fire Alarm Upgrades Questions from Contractors (Through Addendum #2) Communications Systems, Inc.: Legend 1. DL - Dome light symbol should be on the tenant emergency

More information

RFP Addendum 2 March 31, 2016

RFP Addendum 2 March 31, 2016 RFP Addendum 2 March 31, 2016 For Best Value Procurement Option Three Security Upgrades Ph 1 UT Health Science Center SBC No. 540/013-04-2015 This Addendum forms a part of the Request for Proposals (RFP)

More information

ENGINE GENERATORS AND ACCESSORIES

ENGINE GENERATORS AND ACCESSORIES ENGINE GENERATORS AND ACCESSORIES GENERAL INFORMATION 1.1 This section applies to engine generators and accessories. DESIGN REQUIREMENTS 2.1 The Engineer of Record will consult with the University s Engineering

More information

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5 Construction Standards Page 1 of 5.1 General Description.1 The University requires that all new fire alarm system control panel, components, and devices, as required for the project, be Secutron 2900 Series

More information

Related Sections: TBD. Effective Date: January 1, 2016

Related Sections: TBD. Effective Date: January 1, 2016 Description: The purpose of the section is to highlight the current applicable UMCP Design Standards for the design, selection and, installation of lighting fixtures within buildings. Related Sections:

More information

SECTION INTRUSION DETECTION SYSTEM

SECTION INTRUSION DETECTION SYSTEM SECTION 13845 INTRUSION DETECTION SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Section Includes: A complete, operable, tested intrusion detection system, bearing Underwriters Laboratories (UL) mercantile listing

More information

SECTION INTRUSION DETECTION

SECTION INTRUSION DETECTION (NOTE TO DESIGNER: These Specifications are basic minimum criteria to be met in preparing the final specifications for this section, which is the responsibility of the Designer.) SECTION 28 16 00 INTRUSION

More information

IN2 Lighting Control Devices

IN2 Lighting Control Devices Illinois Math and Science Academy DigitalCommons@IMSA Project Manuals IN2 2015 IN2 Lighting Control Devices Illinois Mathematics and Science Academy Follow this and additional works at: http://digitalcommons.imsa.edu/facility_in2_manuals

More information

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

DIVISION 28 ELECTRONIC SAFETY AND SECURITY DIVISION 28 ELECTRONIC SAFETY AND SECURITY CENTRALLY MANAGED ELECTRONIC ACCESS CONTROL, VIDEO SURVEILLANCE, AND INTRUSION ALARM SYSTEMS 1. All questions on equipment approvals in this section shall be

More information

INDEX. Page 2 to 7 Electrical Specifications. Page 8 Electrical Schemes: Basement Plan. Page 9 Electrical Schemes: First Floor Plan

INDEX. Page 2 to 7 Electrical Specifications. Page 8 Electrical Schemes: Basement Plan. Page 9 Electrical Schemes: First Floor Plan 30 Greenway, NW Suite 11 Glen Burnie, Maryland 21061 tel 410.528.8899 fax 410.558.6312 www.gbalternatives.com INDEX Page 2 to 7 Electrical Specifications Page 8 Electrical Schemes: Basement Plan Page 9

More information

COUNTY OF KINGS KINGS COUNTY JAIL EXPANSION PHASE III

COUNTY OF KINGS KINGS COUNTY JAIL EXPANSION PHASE III SECTION 28 3111 - DIGITAL ADDRESSABLE FIRE ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline Moreno Valley Fire Department Guideline Approved and Authorized By: Adria Reinertson, Fire Marshal Issued: May 8, 2017 Alarm & Signaling Systems PURPOSE Fire alarm and signaling systems are designed to

More information

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA PART 1 - GENERAL 1.1 Background SECTION 26 00 10- ELECTRICAL DESIGN CRITERIA A. Brown University maintains it own campus electrical distribution system which serves the majority of the buildings and facilities

More information

SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS

SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS SECTION 260553 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Nameplates and labels B. Wire and cable markers C. Conduit markers 1.2 REFERENCES A. NFPA 70 - National Electrical

More information

SECTION LIGHTING CONTROL DEVICES AND CONTROL PANELS

SECTION LIGHTING CONTROL DEVICES AND CONTROL PANELS SECTION 26 09 23 LIGHTING CONTROL DEVICES AND CONTROL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Remote control lighting relays. 2. Lighting contactors. 3. Switches. 4. Switch plates.

More information

F. GENERAL REQUIREMENTS Electrical Design Criteria 2009 Edition 11/23/2009 School District Palm Beach County Page-1 of 17

F. GENERAL REQUIREMENTS Electrical Design Criteria 2009 Edition 11/23/2009 School District Palm Beach County Page-1 of 17 ELECTRICAL DESIGN CRITERIA TABLE OF CONTENTS I GENERAL...2 II CRITERIA...2 A. POWER DISTRIBUTION SYSTEMS...2 1. NORMAL POWER:... 2 2. EMERGENCY POWER... 3 B. LIGHTING...4 1. GENERAL... 4 2. AVERAGE MAINTAINED

More information

SECTION ADDRESSABLE FIRE ALARM SYSTEM

SECTION ADDRESSABLE FIRE ALARM SYSTEM SECTION 16723 ADDRESSABLE FIRE ALARM SYSTEM 1 PART 1 GENERAL 1.1 DESCRIPTION A. This section outlines the requirements for the installation, programming and configuration of Addressable Fire Alarm System

More information

2009 ELECTRICAL CODE REQUIREMENTS

2009 ELECTRICAL CODE REQUIREMENTS 2009 ELECTRICAL CODE REQUIREMENTS ANTRIM COUNTY BUILDING DEPARTMENT PO BOX 188 205 CAYUGA STREET BELLAIRE, MI 49615 (231) 533-8373 FAX (231) 533-6041 Inspection Request Line (231) 533-3510 Electrical requirements

More information

Technical II Report Electrical Systems

Technical II Report Electrical Systems Technical II Report Electrical Systems Kelly Chan Consultant: Prof T. Dannerth, P.E. Part A Drawings Drawings needed for single-line diagram EE1.01 title sheet (electrical drawings) EE2.09 penthouse/roof

More information

PART 4 ELECTRICAL STANDARDS

PART 4 ELECTRICAL STANDARDS PART 4 ELECTRICAL STANDARDS 1.0 INTRODUCTION AND SCOPE: These standards reflect the general requirements and recommendations of elevator contractors, with respect to the power distribution system to achieve

More information

SPACE TYPE: JUDICIAL CHAMBER

SPACE TYPE: JUDICIAL CHAMBER SPACE TYPE: JUDICIAL CHAMBER Construction Criteria The unit costs for Judicial Chamber space types are based on the construction quality and design features in the following table. This information has

More information

RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS

RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS Key Questions for Residential Inspections 1. What wiring methods will be used, and are the wiring methods suitable for the conditions? 2. Will multiwire branch

More information

CADDY CORPORATION. Utility Distribution Systems

CADDY CORPORATION. Utility Distribution Systems Food Service Equipment Air Systems Utility Distribution Systems page 1 of 2 Equipment Specifications General Specifications Caddy Corporation of America Energy Distribution and Management System, which

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-23 83 00.00 20 (April 2006) -------------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-15768N (September 1999) UNIFIED FACILITIES GUIDE

More information

LIGHTING CONTROL DEVICES

LIGHTING CONTROL DEVICES SECTION - PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this

More information

Architect s Project Number of 12 Fire Alarm/Smoke Detection Systems District Master Specs 2013 Edition

Architect s Project Number of 12 Fire Alarm/Smoke Detection Systems District Master Specs 2013 Edition PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 28 31 00 FIRE ALARM AND SMOKE DETECTION SYSTEMS A. Fire alarm and smoke detection systems 1.2 REFERENCES A. NFPA 72 B. NFPA 101 1.3 REGULATORY REQUIREMENTS A.

More information

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards. SECTION 262416 - PANELBOARDS PART 1 - GENERAL 1.1 SUMMARY A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards. 1.2 PERFORMANCE REQUIREMENTS A. Seismic Performance:

More information

Commercial Remodel/ Add On Rules and Regulations

Commercial Remodel/ Add On Rules and Regulations Commercial Remodel/ Add On Rules and Regulations Public Works and Community Development Department City of Shenandoah 29955 I-45 North Shenandoah, Texas 77381 281-298-5522 www.shenandoahtx.us Construction

More information

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL SECTION 16400 AUTOMATIC TRANSFER SWITCHES 1.01 RELATED DOCUMENTS PART 1 - GENERAL A. Drawings and general provisions of Contract, including General Conditions and Division 1 Specification sections, apply

More information

DIVISION 16 BASIC MATERIALS, METHODS, AND REQUIREMENTS SECTION 16A-1

DIVISION 16 BASIC MATERIALS, METHODS, AND REQUIREMENTS SECTION 16A-1 DIVISION 16 BASIC MATERIALS, METHODS, AND REQUIREMENTS SECTION 16A-1 PART 1: GENERAL 1.1 SUMMARY.1 This section covers materials, methods, and requirements common to all electrical work..2 When it becomes

More information

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS PART 1 GENERAL 1.1 SECTION INCLUDES A. Fire alarm and smoke detection systems 1.2 REFERENCES A. NFPA 72 B. NFPA 101 1.3 REGULATORY REQUIREMENTS A. System: UL listed B. Conform to requirements of NFPA 101

More information

CARD ACCESS CONTROL SYSTEM

CARD ACCESS CONTROL SYSTEM SECTION 13851 CARD ACCESS CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Section Includes: A complete, operable, tested, integrated proximity access control system, to operate on a proximity principle where

More information

BASIC ELECTRICAL ENGINEERING FOR CE

BASIC ELECTRICAL ENGINEERING FOR CE EE24 BASIC ELECTRICAL ENGINEERING FOR CE LECTURE NO. B-2 Basic Electrical Code Provisions Codes/Standards/Organizations PEC Philippine Electrical Code NEC National Electrical Code IEEE - Institute of Electrical

More information

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Fire Alarm Systems Plan Review Checklist Date: Permit Number: Business Name: Address: Fire Alarm System Submittal

More information

Commercial Rules and Regulations

Commercial Rules and Regulations Commercial Rules and Regulations Public Works and Community Development Department City of Shenandoah 29955 I 45 North Shenandoah, Texas 77381 281 298 5522 www.shenandoahtx.us Construction Documents Submit

More information

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the

More information

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

DIVISION 28 ELECTRONIC SAFETY AND SECURITY 281300 - ACCESS CONTROL A. General DIVISION 28 ELECTRONIC SAFETY AND SECURITY At the beginning of the project, schedule a meeting with the Facilities Access/Maintenance Coordinator with questions and concerns.

More information

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards. SECTION 262416 - PANELBOARDS PART 1 - GENERAL 1.1 SUMMARY A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards. 1.2 PERFORMANCE REQUIREMENTS A. Seismic Performance:

More information

Michigan State University DESIGN GUIDELINES. ELECTRICAL DESIGN Page 1 TABLE OF CONTENTS 1

Michigan State University DESIGN GUIDELINES. ELECTRICAL DESIGN Page 1 TABLE OF CONTENTS 1 Page 1 TABLE OF CONTENTS 1 ELECTRICAL 2 Summary Sustainability Electrical Distribution Lighting Detection and Alarm Communication Systems Lightning Protection Clock Systems Access Control Housekeeping

More information

DIVISION 16 - ELECTRICAL

DIVISION 16 - ELECTRICAL DIVISION 16 - ELECTRICAL I. GENERAL A. This division contains the following elements: 1. Electrical Distribution System. 2. Power System. 3. Lighting System. 4. Emergency Power System. 5. Fire Alarm Detection

More information

SECTION FIRE ALARM SYSTEMS

SECTION FIRE ALARM SYSTEMS SECTION 16721 FIRE ALARM SYSTEMS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work

More information

Page 1 of General

Page 1 of General Page 1 of 8 16.1 General 1. This section covers items common to sections of CSI s Master Format - Division 16. 2. Dalhousie University is certified by IBEW for new construction and all electrical contractors

More information

NOTICE TO ALL FIRMS. Bid RFI Questions and Answers

NOTICE TO ALL FIRMS. Bid RFI Questions and Answers Purchasing Department 227 West 27 th Street New York, NY 10001 Purchasing Dept. Tel. 212-217-3630 Purchasing Dept. Fax 212-217-3631 Purchasing@fitnyc.edu NOTICE TO ALL FIRMS Date: March 8, 2018 To: From:

More information

ALBUQUERQUE PUBLIC SCHOOLS Facility Design & Construction / Maintenance & Operations ELECTRICAL STANDARDS DESIGN CHECKLIST

ALBUQUERQUE PUBLIC SCHOOLS Facility Design & Construction / Maintenance & Operations ELECTRICAL STANDARDS DESIGN CHECKLIST ALBUQUERQUE PUBLIC SCHOOLS Facility Design & Construction / Maintenance & Operations ELECTRICAL STANDARDS DESIGN CHECKLIST February 01, 2006 2 Project Name: Architect: Electrical Engineer: Completed By:

More information

Town of Cicero Local Code Amendments

Town of Cicero Local Code Amendments Town of Cicero Local Code Amendments 2009 International Residential Code Local Amendments: DELETE Table R302.1 (Exterior Walls), see Attachment A. DELETE Exception for Subsection R313.2 (One and Two-Family

More information

SECTION EXTERIOR LIGHTING

SECTION EXTERIOR LIGHTING SECTION 26 56 00 PART 1 - GENERAL 1.1 DESCRIPTION This section specifies the furnishing, installation, and connection of exterior luminaries, controls, poles and supports. 1.2 RELATED WORK A. Section 26

More information

Changes to this Division since the last issuance are indicated with yellow highlighted text.

Changes to this Division since the last issuance are indicated with yellow highlighted text. Table of Contents 28 10 00 ELECTRONIC ACCESS CONTROL AND INTRUSION DETECTION... 2 A. GENERAL... 2 B. DESIGN REQUIREMENTS... 2 C. CONSTRUCTION REQUIREMENTS... 3 28 20 00 ELECTRONIC SURVEILLANCE... 4 A.

More information

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST DATE: PROJECT NO.: EXPIRATION DATE: STATUS: INFORMATION PROJECT ADDRESS:

More information

Fire Sprinkler Plan Submittal Form

Fire Sprinkler Plan Submittal Form Contents Fire Sprinkler Plan Submittal Form... 2 Standpipe Plan Review Submittals... 4 Fire Pump Plan Submittal Requirements... 6 Fire Alarm Plan Submittal Form... 8 Kitchen Hood Wet Chemical Submittal...10

More information

MEDICAL OFFICE BUILDING

MEDICAL OFFICE BUILDING P A U L MEDICAL OFFICE BUILDING SUNNYVALE, TX ISSUED FOR PERMIT & CONSTRUCTION PAUL PASCARELLI ARCHITECT ISSUED FOR PERMIT & CONSTRUCTION P A U L ISSUED FOR PERMIT & CONSTRUCTION P A U L ISSUED FOR PERMIT

More information