Engine Fire Protection System
|
|
- Raymond Cobb
- 5 years ago
- Views:
Transcription
1 Engine Fire Protection System 1 1 LEFT FEED BUS LEFT CB PANEL CROSSOVER RIGHT FEED LEFT CB PANEL Fire Protection ARM UNLOCK DEPLOY S T EMER O W S NORM W BOTTLE 1 ARMED PUSH LH ENG FIRE PUSH RH ENG FIRE PUSH BOTTLE 2 ARMED PUSH S EMER T O W NORM S W ARM UNLOCK DEPLOY HYD F/W LH FUEL F/W LH FIRE DET FAIL LH RH FUEL VALVE L R HYDRAULIC VALVE FIRE CONTROL UNIT TEE CHECK VALVE SQUIB SQUIB 1 2 SQUIB SQUIB T / R ISOLATION VALVE FIRE DETECTOR LOOP FIRE EXT BOTTLE LOW 1 UNITS 0152 AND SUBSEQUENT, BOTH SIDES OF THE SYSTEM RECEIVE 28V DC FROM THE EMERGENCY BUS THROUGH SEPARATE 2 AMP CBs TEE CHECK VALVE PRESSURE SWITCH FUEL PRESSURE HYDRAULIC PRESSURE HALON 1301 FIRE LOOP Citation III/VI For training only 4D-1
2 Engine Fire Detection System LEFT ENGINE FIRE PUSH SWITCH THRUST REVERSER HYDRAULIC CUTOFF LEFT THRUST REVERSER ISOLATION VALVE GENERATOR TRIP TRIP LEFT GENERATOR CONTROL UNIT CUTOFF LEFT FUEL AND HYDRAULIC CUTOFF VALVES HYD F/W LH FUEL F/W LH ARM BOTTLE NUMBER 1 PUSH TO FIRE LOW PRESSURE ARM BOTTLE NUMBER 2 BOTTLE NUMBER 1 ARMED SWITCH EXTINGUISHER BOTTLE NUMBER 1 RIGHT ENGINE FIRE PUSH SWITCH FIRE EXT BOTTLE LOW ARM BOTTLE NUMBER 1 BOTTLE NUMBER 2 ARMED SWITCH EXTINGUISHER BOTTLE NUMBER 2 ARM BOTTLE NUMBER 2 PUSH TO FIRE RIGHT FUEL AND HYDRAULIC CUTOFF VALVES LOW PRESSURE HYD F/WI RH CUTOFF FUEL F/W RH GENERATOR TRIP TRIP RIGHT GENERATOR CONTROL UNIT THRUST REVERSER HYDRAULIC CUTOFF RIGHT THRUST REVERSER ISOLATION VALVE 4D-2 For training only Citation III/VI
3 Fire Detection Engine Fire Protection The engine fire detection system consists of a stainless steel sensing tube that wraps around the engine combustion section and accessory section. A responder assembly connected to the sensing tube has two pressure switches: alarm responder and integrity responder. When subjected to high temperatures, the inert gas in the sensing tube expands and exerts pressure against the alarm responder switch. When the switch closes, it completes a circuit within the fire detection control unit box to illuminate the respective LH/RH ENG FIRE PUSH switchlight and sound the fire bell. After three seconds, a time delay relay silences the fire bell. If the sensing tube develops a leak and the inert gas escapes, the loss of pressure opens the normally closed integrity responder pressure switch to illuminate the respective amber LH/RH DET FAIL annunciator. APU On aircraft with a Turbomach APU, the fire detection system consists of a fire detection loop that surrounds the APU powerplant. On flight operable APUs, an additional fire detection loop mounts to the inside of the APU enclosure. As a fire or bleed air leak heats the fire detection loop(s), resistance of the loop decreases until current flows from its core to its outer sheath to complete a circuit to the fire control unit. The fire control unit then illuminates the APU FIRE switchlight, triggers the flashing Master Warning lights, and sounds the fire bell. Citation III/VI For training only 4D-3
4 On aircraft with the Duncan installed GTCP36-150W APU, the fire detection system consists of four spot detectors strategically located on the APU and APU enclosure. If a fire or bleed air leak occurs, the spot detectors trigger the flashing APU control panel APU FIRE PUSH switchlight and the Master Warning lights and sound the fire bell. Pressing the APU FIRE PUSH switchlight closes the APU fuel shutoff valve, arms the fire extinguishing system, and initiates an automatic APU shutdown. Pressing the FIRE TEST button tests the APU fire detection circuits. If the APU FIRE PUSH switchlight and Master Warning lights flash and the fire bell sounds, the system is operating normally. Smoke A smoke detector under the aft cabin floor near the outflow provides cabin fire detection. If a cabin fire develops, smoke in the air exiting the outflow valve triggers the smoke detector. The detector operating on 28V DC from the Crossover Left Feed bus illuminates the SMOKE DETECT annunciator and triggers the Master Warning lights. Testing Placing the rotary TEST switch in SMOKE FIRE WARN tests the engine and cabin fire detection systems. Illumination of the ENG FIRE PUSH switchlights and SMOKE DETECT annunciator, sounding of the fire bell, and flashing Master Warning lights denotes proper system operation. 4D-4 For training only Citation III/VI
5 Fire Extinguishing Engine Fire Protection Two dual-head single-shot fire extinguisher bottles in the tail compartment contain Halon 1301 (bromotrifluoromethane) pressurized with nitrogen. Each bottle has a temperature compensating switch, a combination fill and safety valve outlet, and two discharge valves and outlets. When the fire detection system senses an engine fire or overheat, it illuminates the associated ENG FIRE PUSH switchlight, triggers the flashing Master Warning lights, and sounds the fire bell for three seconds. Pressing the ENG FIRE PUSH switchlight arms the fire extinguishing system (BOTTLE 1/2 ARMED PUSH switchlights illuminated). This action also closes the fuel and hydraulic firewall valves, trips the affected engine s generator offline, and closes the thrust reverser isolation valve. Pushing the BOTTLE 1 or 2 ARMED PUSH switchlight supplies 28V DC to fire the explosive cartridge and release bottle contents to the affected engine. Pressurized nitrogen carries the fire extinguishing agent from the bottle through distribution lines to the engine nacelle. If the ENG FIRE PUSH light remains illuminated after 30 seconds, pressing the other BOTTLE ARMED PUSH switchlight discharges the other bottle into the same engine nacelle. After bottle discharge, the FIRE EXT BOTTLE LOW annunciator illuminates. If bottle pressure falls below 500 ±25 PSIG, the bottle s temperature compensating switch illuminates the FIRE EXT BOTTLE LOW annunciator. If this occurs, the bottle must be removed and serviced by an appropriate agency. The bottle also has a fusible plug in the safety valve that reacts to bottle overheat by melting and releasing bottle contents through the fill port into the tail compartment. Citation III/VI For training only 4D-5
6 APU Depending on the APU installed and service bulletin compliance, varying APU fire extinguishing systems are installed. This includes: units 001 to 121 with Cessna installed Turbomach APU: single bottle discharges into APU enclosure (shroud) aircraft with SB : one bottle discharges into APU enclosure and one bottle discharges into APU air inlet ground and flight certified APUs: larger single bottle discharges into APU enclosure PATS, Inc. installed Turbomach APU: single bottle discharges into APU enclosure Duncan STC SA2110CE Garrett GTCP36-150: single bottle discharges into APU enclosure. The APU fire extinguishing bottle(s) is similar to the engine fire extinguisher bottle except that it has a single discharge outlet. A temperature compensating switch illuminates the APU FAIL light if bottle pressure drops to approximately 500 PSI. If the light illuminates, the bottle must be removed and serviced. On aircraft with SB and ground/flight APUs, t he extinguisher bottle(s) also has a pressure gage. When exposed to high temperatures, the APU fire detection system control unit illuminates the APU FIRE switchlight, sounds the fire bell, and energizes the time delay relay. Pressing the illuminated APU FIRE or FIRE EXT (Duncan) switchlight supplies 28V DC to fire the bottle s explosive cartridge and supply extinguishing agent to the APU enclosure. If the crew fails to act within eight seconds, the time delay relay automatically fires the explosive cartridge (except Duncan installation). 4D-6 For training only Citation III/VI
7 Fire Protection On aircraft with SB , the APU fire extinguishing system automatically arms when the single-point refueling door opens or unlatches, the APU READY-TO-LOAD light illuminates (APU operating), and the left main gear squat switch indicates aircraft on ground. If the APU fails or an APU fire occurs during refueling, the fire extinguishing system automatically discharges extinguishing agent into the APU air inlet. Do not shut down the APU or close and latch the single-point refueling door before shutting down the APU. These precautions prevent inadvertent bottle discharge during refueling with the APU operating. Portable Fire Extinguishers Portable fire extinguishers in the cockpit and cabin (varies with government regulations) contain Halon 1211 (bromochlorodifluoromethane). Halon 1211 is a relatively non-toxic fire extinguishing agent that leaves no residue and is effective on most fires that occur in the aircraft. Citation III/VI For training only 4D-7
8 Engine Fire Protection Power Source Distribution Control Monitor Protection Left and Right Feed buses 28V DC Emergency Crossover bus (unit 152 and subsequent) Each bottle to either engine Fire control unit LH/RH ENG FIRE PUSH switchlights BOTTLE 1/2 ARMED PUSH switchlights Annunciators LH/RH ENG FIRE PUSH LH/RH FIRE DETECT FAIL FIRE EXT BOTTLE LOW LH/RH FUEL F/W LH/RH HYD F/W Fire bell SMOKE/FIRE/WARN system test Circuit breakers Bottle fusible plug 4D-8 For training only Citation III/VI
9 Fire Protection APU Fire Protection Power Source Distribution Control Monitor Protection Left Feed bus 28V DC APU fire extinguisher bottle(s) Fire detect sensor Distribution lines and nozzles APU enclosure (shroud) APU combustor shroud* APU air inlet* Fire control unit APU FIRE PUSH switchlight FIRE EXT switchlight (Duncan only) Time delay relay (except Duncan) APU FAIL light (low bottle pressure) APU FIRE PUSH switchlight Fire bell APU TEST PUSH switch Circuit breakers Bottle fusible plugs * Varies with APU installed. Citation III/VI For training only 4D-9
10 4D-10 For training only Citation III/VI
Bombardier Challenger Fire Protection
GENERAL The fire protection system is divided into two separate subsystems: Fire and overheat detection system; and Fire extinguishing system. The fire and overheat detection system includes components
More informationFire Extinguishing System
Fire Extinguishing System Fire Protection CAUTION CAUTION 1 EXTINGUISHER PUSH L ENGINE FIRE R FW VALVE CLOSED TO TEST R ENGINE FIRE R FW VALVE CLOSED EXTINGUISHER PUSH 2 TEST SWITCH 1 ANNUNCIATOR PANEL
More informationDASSAULT AVIATION Proprietary Data
F2000EX EASY 02-26-00 CODDE 1 PAGE 1 / 2 TABLE OF CONTENTS 02-26 02-26-00 TABLE OF CONTENTS 02-26-05 GENERAL Introduction Sources 02-26-10 DESCRIPTION Introduction Fire detection Fire extinguishing Portable
More informationSECTION 6-15 FIRE PROTECTION
SECTION 6-15 SYSTEMS DESCRIPTION Index Page General Description... 6-15-2 Engine Fire Protection... 6-15-2 Engine Fire Detection... 6-15-2 Engine Extinguishing... 6-15-3 Engine/Wheelwell and Pipe Zone
More informationSECTION 2-07 FIRE PROTECTION
SECTION 2-07 TABLE OF CONTENTS Block General... 2-07-05..01 Engine and APU Fire Protection System... 2-07-10..01 Fire/Overheat Detection... 2-07-10..01 Fire Extinguishing... 2-07-10..04 Controls and Indicators...
More informationAPU FIRE EXTINGUISHING SYSTEM - DESCRIPTION AND OPERATION
1.General APU FIRE EXTINGUISHING SYSTEM - DESCRIPTION AND OPERATION A.The APU fire extinguishing system has controls in two locations that release one application of fire extinguishing agent to a fire
More informationFokker 50 - Fire Protection
ENGINE General The engines are each equipped with a fire detection and a fire extinguishing system. The systems are controlled from the ENGINE FIRE panel, which is located at the overhead panel. Fire and
More informationWARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS
WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS The Warning and Caution systems are discussed here in conjunction with the Warning and Test Systems, primarily to cover the procedures for testing
More informationTABLE OF CONTENTS FIRE PROTECTION. Page. 9-i
Chapter 9: Fire Protection TABLE OF CONTENTS Page Introduction...9-1 Flight Compartment Fire Warning...9-2 Fire Detecting System...9-2 Main Wheel Well Overheat Warning...9-2 Fire Agent Discharge Indication...9-2
More informationSection - III SYSTEMS DESCRIPTION
Section - III SYSTEMS DESCRIPTION Table of Contents Hawker 800XP Pro Line Page GENERAL...4-3 Figure - Engine Fire Detection and Warning System Component Locations...4-3 CONTROLS and INDICATIONS...4-4 ENGINE
More informationFIRE PROTECTION TABLE OF CONTENTS CHAPTER 9
TABLE OF CONTENTS CHAPTER 9 Page TABLE OF CONTENTS DESCRIPTION General Flight Compartment Fire Warning Fire Detecting System Wheel Well Overheat Warning Fire Agent Discharge Indication Smoke Detection
More informationWARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS
MODEL 680 WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS The Warning and Caution systems are discussed here in conjunction with the Warning and Test Systems, primarily to cover the procedures
More information71717 SERIES FLAMMABLE MATERIAL LOCATIONS
71 FLAMMABLE MATERIAL LOCATIONS (tab) CAUTION: Rescue crews wearing full PPE to include SCBA s must use caution when moving across sections of aircraft that have been exposed to fatigue or fire as the
More informationDASSAULT AVIATION Proprietary Data
FALCON 7X 02-33-05 CODDE 1 PAGE 1 / 4 GENERAL ACRONYMS LIST BATT CB EPS LED LH MAU OP PPDB RH SSPC Battery Circuit Breaker Emergency Power Supply Light Emitting Diode Left Hand Modular Avionic Unit Overhead
More informationDC3Training.com N28AA DC-3 Pilot s Handbook
SECTION 7 FIRE PROTECTION Index General page 2 Operation page 4 Limitations page 4 Troubleshooting page 5 4/19/2012 crew@dc3training.com 1 GENERAL The fire protection system consists of an Edison fire
More informationDASSAULT AVIATION Proprietary Data
F900EX EASY 02-38-00 CODDE 1 PAGE 1 / 2 TABLE OF CONTENTS 02-38 02-38-00 TABLE OF CONTENTS 02-38-05 GENERAL Introduction Sources Equipment location 02-38-10 DESCRIPTION General 02-38-15 CONTROL AND INDICATION
More informationDornier 328Jet - Lights
LIGHT and ENGINE START Control Panel (Sheet 1 of 5) Page 1 Light and ENGINE START Control Panel (Sheet 2 of 5) Page 2 LIGHT and ENGINE START Control Panel (Sheet 3 of 5) Page 3 LIGHT and ENGINE START Control
More informationT-6B Electrical System. Created: 24 Aug 2015 Updated: 30 Aug 2015 T6BDriver.com
T-6B Electrical System Created: 24 Aug 2015 Updated: 30 Aug 2015 T6BDriver.com Objectives Identify power sources of electrical system Understand electrical distribution within system Identify location
More informationT0158_ATRcouvDEF_SYSTEM42notPEC.indd COUV1 19/05/10 16:29
42-300 Introduction This Systems guide is an essential tool for all ATR flight crew and engineer to learn or review ATR systems operation. To make learning process easier, systems are introduced in a user-friendly
More informationPressurization System
Pressurization System FILTER N.O. PRESET SOLENOID MOISTURE DRAIN ALTITUDE LIMIT CONTROLLER ALTITUDE LIMIT CONTROLLER MOISTURE DRAIN OUTFLOW SAFETY STATIC AIR Environmental Systems RATE ALTITUDE VACUUM
More informationDASSAULT AVIATION Proprietary Data
F2000EX EASY 02-38-00 CODDE 1 PAGE 1 / 2 TABLE OF CONTENTS 02-38 02-38-00 TABLE OF CONTENTS 02-38-05 GENERAL Introduction Sources Equipment location 02-38-10 DESCRIPTION General 02-38-15 CONTROL AND INDICATION
More informationSAFETY INFORMATION NOTICE
No. 2854-S-00 SAFETY INFORMATION NOTICE SUBJECT: GENERAL For the attention of Ground Rescue Booklet AIRCRAFT CONCERNED Civil LP Version(s) Military EC225 Flight safety is the first priority for Airbus
More informationKelly Aerospace Willoughby, OH NC , Rev. A FAA APPROVED AIRPLANE FLIGHT MANUAL SUPPLEMENT FOR LC40-550FG AIRFRAME DE-ICING SYSTEM
Aircraft SN: Aircraft Registration Number: This supplement must be attached to the FAA approved flight manual when the Kelly Aerospace airframe de-icing system is installed in accordance with STC SA02660CH.
More informationSection - III SYSTEMS DESCRIPTION
Section - III SYSTEMS DESCRIPTION Pro Line 21 Table of Contents Page GENERAL...1-3 ANNUNCIATOR TYPES...1-3 ARRANGEMENT...1-3 REPEATER ANNUNCIATORS...1-3 Figure 1 - Master Warning Annunciations and Controls...1-4
More informationCanadair Regional Jet 100/200 - Lighting
1. INTRODUCTION The lighting system provides interior and exterior illumination of the aircraft and consists of: Flight Compartment Lighting Passenger Compartment Lighting Service and Maintenance Lighting
More informationCanadair Regional Jet 100/200 - Water & Waste
INTRODUCTION The water and waste systems include potable water, lavatory waste equipment and system controls. Two potable water systems store and supply potable water to the galley and lavatory. The forward
More informationOWNERS MANUAL MODEL 451 (-101 & -201)
OWNERS MANUAL MODEL 451 (-101 & -201) Guardian Avionics CO Guardian, LLC. 1951 E Airport Drive Tucson, AZ 85756 Phone: 520-889-1177 8:00 am - 5:00 pm MST support@guardianavionics.com 2 Table of Contents
More informationCHAPTER 11 AIR CONDITIONING
CHAPER 11 AIR CONDIIONING INRODUCION his chapter describes the Citation Mustang air-conditioning systems. Information is provided on temperature-controlled pressurized air, vapor-cycle air conditioning,
More informationFIRE EXTINGUISHING SYSTEM
SEEGER. FIRE EXTINGUISHING SYSTEM 443cl TICHlllCAL TRAINING SQUADRON 44311 MILITARY AIRLIFT W G, ING (MAC) ALTUS AIR FORCE BASE, OKLAHOMA A FIRE E){TINGUISHING SYST~ OBJECTIVES~ When you complete this
More informationSection - III SYSTEMS DESCRIPTION
Section - III SYSTEMS DESCRIPTION Pro Line 21 Table of Contents Page GENERAL... 7-3 SYSTEM LOGIC... 7-3 CONTROLS and ANNUNCIATIONS... 7-3 OPERATION... 7-4 STALL WARNING SYSTEM... 7-4 STALL IDENTIFICATION
More informationInstrument and Control Panels
GENERAL Instrument and Control Panels 31-10: INSTRUMENT AND CONTROL PANELS 1. General A. Instrument Panel A Garmin Primary Flight Display (PFD) is mounted in the instrument panel. The Engine Start Controls
More informationUnited States Army Warfighting Center Fort Rucker, Alabama SEPTEMBER 2006
United States Army Warfighting Center Fort Rucker, Alabama SEPTEMBER 2006 STUDENT HANDOUT TITLE: CH 47D ENVIRONMENTAL SYSTEMS FILE NUMBER: 011 2111-1 PROPONENT FOR THIS STUDENT HANDOUT IS: 110 th Aviation
More informationMemory Items 2
Flash Cards 1 Memory Items 2 Memory Items ENGINE FAILURE/EMERGENCY ENGINE SHUTDOWN 3 Memory Items ENGINE FAILURE/EMERGENCY ENGINE SHUTDOWN 1. Condition lever FUEL CUTOFF 2. Propeller lever FEATHER 3. Firewall
More informationElement C3.4 Fire Fighting Equipment
.4 Fire Fighting Equipment Classification of Fires Class A Solids. Wood, paper, plastics Class B Liquids Petrol oil, paint Class C Gases LPG, natural gas Classification of Fires Class D Metals Zinc, sodium,
More informationBasic Vehicle Fire Protection Manual
Basic Vehicle Fire Protection Manual Basic Vehicle Fire Protection Manual TABLE OF CONTENTS Introduction... 3 System Operation...... 5 Component Overview.... 7 Operator Controls Control Panel.........
More informationType 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B
PRODUCT BULLETIN SB 8001B Type 8001 ALARM ANNUNCIATOR TYPE8001 FEATURES 16 or 32 alarm points per flush mount enclosure Displays are backlit with long life LEDs and engraved to suit Dimmer controls built
More informationSD3-60 AIRCRAFT MAINTENANCE MANUAL SYSTEM - DESCRIPTION & OPERATION (PRE MOD A8005)
SD3-60 AIRCRAFT MAINTENANCE MANUAL z AMM 22.0.0.0STALL WARNING SYSTEM - DESCRIPTION & OPERATION (PRE MOD A8005) 1. Description A. General Physical and aural warning of an incipient stall condition is respectively
More informationFokker 50 - Integrated Alerting Unit
GENERAL Failure conditions are processed by an Integrated Alerting Unit (IAU) for visual and aural presentation to the pilots. Pre-stall warning and ground proximity warning are not integrated. The IAU
More informationService Bulletin No. 2930
Service Bulletin No. 2930 MODEL TYPE SECTION/GROUP DATE E / J Series Coaches Service Information 8--Engine Mar. 30, 2006 SUBJECT AMEREX FIRE SUPPRESSION SYSTEM CONDITIONS Service Information Only Description:
More informationKelsow Work Instruction. Buffalo Venture FPSO Fire Protection Systems
Kelsow Work Instruction Buffalo Venture FPSO Fire Protection Systems Table of Contents Abbreviations and Definitions....................................................... 2 Overview............................................................................
More informationSigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009
Sigma K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels Operation and Maintenance Manual Man-1048 Issue 05 October 2009 CONTENTS Contents... Page Safety & Installation...2 Installation - continued...3
More informationA380 Special Condition D 04 Crew Rest Compartment
A380 Special Condition D 04 Crew Rest Compartment 1 CRC occupancy is not allowed during Taxi, Take off and Landing (TT&L) phases except for the Flight Crew Rest Compartments where Special Condition 20
More informationSystem Test Report CLEAN AGENT
City of Black Hawk Fire Department 196 Clear Creek Street PO Box 68 Black Hawk, CO 80422-068 Office 303-582-0426 Fax 303-582-2229 www.cityofblackhawk.org System Test Report CLEAN AGENT Occupancy Information
More information1 Aviation English Vocabulary Level 4 to 5
1 Aviation English Vocabulary Level 4 to 5 Vocabulary: Engine Fire Describe the photograph. Try to speak for at least 30 seconds. Match the words to make a noun adjective or verb. eg fire extinguisher
More informationAPPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview
Overview Modern combustion (or gas) turbine packages typically include an axial compressor, a combustion section and a turbine. Both compressor and turbine sections consist of one or more sets of fixed
More informationCO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL
OWNERS MANUAL CARBON MONOXIDE DETECTOR MODELS Panel mount and Remote Detectors (R) (353 and 353R) 353 FAMILY MODEL OWNERS/INSTALLATION MANUAL Page 1 of 22 LOG OF REVISIONS REV NO. PAGE NO. DATE DESCRIPTION
More information182T and T182T Air Conditioning System ICA Revision: Date: 17 September, 2008
Document Number: NC-08-037 Title: 182T and T182T Air Conditioning System ICA Revision: C Date: 17 September, 2008 Name Signature Date Author Erik Pederson Signed Copy On File 9/17/08 Approved Erik Pederson
More informationOWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ.
OWNERS MANUAL CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) (353-101 and 353-201) 353 FAMILY MODEL OWNERS/INSTALLATION MANUAL Page 1 of 22 LOG OF REVISIONS REV NO. PAGE NO. DATE DESCRIPTION
More information1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection
Technical Bulletin Arc Fault Monitor 4 Zones, 8 Sensors Features Four independent arc fault tripping zones 1 or 2 arc fault sensors per zone allowing up to 8 arc fault sensors per module Trip indication
More informationEnd To End Optical Beam Smoke Detector. Additional Information
End To End Optical Beam Smoke Detector Additional Information EN 1. Multiple Zone Wiring When using more than one System Controller on a single zone of a conventional Fire Control Panel (FCP), it is important
More informationFire. IMO fire control signs - according to IMO Resolution A.654 (16) (mm) 150x x200
IMO fire control signs - according to IMO Resolution A.654 (16) Safety and operating instructions for trained personnel (SIS) - As per ISO 24409, SIS signs are safety-related signs that replicate the symbols
More informationHazardous Material Safety Program
Hazardous Material Safety Program Lithium Battery History and Testing Presented By: Date: Discussion Topics Challenges for mitigating lithium battery risks as technology advances What do we know from research
More informationHIGH-RISE RETROFIT ORDINANCES - NO and NO
INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LAMC 91.8604 Effective: 9-06-90 DOCUMENT NO. P/BC 2002-054 Revised: 4-15-03 Previously Issued As: MGD 88 HIGH-RISE RETROFIT ORDINANCES - NO.
More informationSection 11. Heating and Ventilation. Heating & Ventilation Systems. 1 of 6
Heating and Ventilation 1 of 6 HEATING AND VENTILATION SYSTEM General Ambient air, drawn in by a fan through a vent in the cowling above the cockpit is mixed with hot air (P2), tapped from the engines,
More informationCIRRUS AIRPLANE MAINTENANCE MANUAL
INDICATING/RECORDING SYSTEMS 1. DESCRIPTION This section describes the Indicating/Recording Systems which consists of an Annunciator Panel and related sensors and switches. A. Annunciator Panel - Serials
More informationAnalog Room Pressure Monitor RPC Series
Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the
More informationFire Safety and Utility Controls. CERT Basic Training Unit 2
Fire Safety and Utility Controls Unit 2 Unit Objectives Explain role of CERTs in fire safety Identify and reduce potential fire and utility risks Describe CERT sizeup process Conduct basic sizeup for a
More informationSERVICE BULLETIN REVISION
Revision 1 REVISION TRANSMITTAL SHEET This sheet transmits Revision 1 to, which: A. Changes the test for the operation of the switch installation. B. Adds steps to drill a hole in the cabin entrance door
More informationSPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE CHEETAH Xi 50 CONTROL PANEL SYSTEM
SECTION 1 - GENERAL CONDITIONS I. SCOPE: This specification outlines the requirements for a Total Flood ECARO-25 TM clean agent fire suppression system utilizing HFC-125 as the fire extinguishing agent
More informationIntelligent Security & Fire Ltd
OPERATIONAL NOTES FOR CONCEPT FIRE PANEL. NOTE ON NEW FIRE PANELS, POSITION 1 ON THE SIX WAY INTERNAL OPTION SWITCH IS TURNED ON, DISABLING THE ZONAL SOUNDERS. TO ENABLE ZONAL SOUNDERS TURN OFF. Operation
More informationData Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906
s Data Sheet Fire Safety & Security Products SXL-EX Fire Alarm Control Panel Conventional Zone Fire Alarm Control Panel ARCHITECT AND ENGINEER SPECIFICATIONS Four (4) zones expandable to eight (8) zones
More informationDUAL MONITORED INPUT/OUTPUT UNIT BN-305-2
DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2 Interactive fire detection systems Product Datasheet Features Interactive For interfacing and controlling external units to Autronica s interactive fire detection
More informationFire Safety and Utility Controls. CERT Basic Training Unit 2
Fire Safety and Utility Controls Unit 2 Unit Objectives Explain role of CERTs in fire safety Identify and reduce potential fire and utility risks Describe CERT sizeup process Conduct basic sizeup for a
More informationDUAL MONITORED INPUT/OUTPUT UNIT BN-305
DUAL MONITORED INPUT/OUTPUT UNIT BN-30 Interactive fire detection systems Product Datasheet Features Interactive For interfacing and controlling external units to Autronica s interactive fire detection
More informationInstallation Guide for inbiox60 Series Access Control Panel
Installation Guide for inbiox60 Series Access Control Panel Version: 1.0 Date: April, 2011 About This Manual This manual is a guide to installation and connection of the inbiox60 series access control
More informationUser s Manual. For the SHORE POWER CONNECTION MONITOR MODEL 9151
User s Manual For the SHORE POWER CONNECTION MONITOR MODEL 9151 Table of Contents: Product Description... 3 Installation... 4 Optional Remote Alarm Installation... 7 Operator Test... 8 Alarms... 9 Figures...
More information1987 FALCON 900B SN 33
1987 FALCON 900B SN 33 127 LUBRANO DRIVE STE. 200 ANNAPOLIS, MD 21401 PH: (410) 573-1203 F: (410) 573-1205 1987 FALCON 900B SN 33 For more information, please contact: AIRFRAME 11,763 Hours 6,577 Landings
More informationP.68 VARIANTS. SERVICE BULLETIN No. 195 Rev. 1 (Supersedes the previous issue dated 19 February 2014)
vulcanair spa via g. pascoli, 7 80026 Casoria (Na) Italy Tel +39 081 5918111 Fax +39 081 5918172 info@vulcanair.com www.vulcanair.com P.68 VARIANTS Approved by the Vulcanair Design Organisation The technical
More informationgeneric moving map with bezel removed Avidyne Entegra MFD for Piper or Cirrus aircraft Avidyne Entegra PFD for Piper or Cirrus aircraft
AvSimMap_II.ac Avidyne map generic moving map AvSimMap_II_nobezel.ac Avidyne map generic moving map with bezel removed AvSimMFD_all.ac Avidyne MFD Avidyne Entegra MFD for Piper or Cirrus aircraft AvSimPFD_all.ac
More informationAgent Tanks PCL PCL PCL PCL - 600
Components Pg 2-1 Agent Tanks PCL - 160 PCL - 300 PCL - 460 PCL - 600 Model No. Diameter Height to top of valve Height with control head Height to valve outlet Weight PCL - 160 8.00 in. 17.65 in. 23.50
More informationA D U ANNUNCIATOR DIM / TEST UNIT INSTALLATION MANUAL DESCRIPTION AND THEORY OF OPERATION
AVIONICS ENGINEERING SERVICES A D U ANNUNCIATOR DIM / TEST UNIT INSTALLATION MANUAL DESCRIPTION AND THEORY OF OPERATION Document No. 92-0003-06 REV C May 31, 2000 INSTALLATION MANUAL DESCRIPTION AND THEORY
More informationInstallation and Operation Manual AEC9005 Series Low Voltage Warning and Auxiliary Battery Management Modules
Bob Nuckolls 6936 Bainbridge Road Wichita, Kansas 67226-1008 Voice/Fax: 316-685-8617 E-mail: http://www.aeroelectric.com/bob.nuckolls Installation and Operation Manual AEC9005 Series Low Voltage Warning
More informationSPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM
SECTION 1 - GENERAL CONDITIONS SPECIFICATION FOR A TOTAL FLOOD I. SCOPE: This specification outlines the requirements for a Total Flood ECARO-25 TM clean agent fire suppression system utilizing HFC-125
More informationMINIMUM EQUIPMENT LIST ATA 33 - LIGHT F-27 Mk 050
ATA LIGHT F7 Mk 5 MNLFL Version :.9.Sep. of 5 NUMBER INSTALLE NUMBER REQUIRE FOR ISPATH N Flight deck and instrument REMARKS AN/OR EXEPTIONS Lights sufficient to clearly illuminate all instruments and
More informationSYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System
SYSTEM MANUAL FT1-SB Single Zone Fire Alarm System DOCUMENT HISTORY Issue Date Description Written By Checked By Draft 0 2/9/2008 Original Document. A. Shenouda C. Orr Issue 1 4/11/2011 Update drawing
More informationHOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4
HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4 INTRODUCTION Thank you for purchasing the Hokkim Integrated Automatic Mains Failure Control Board model HAMF- 8 or HAMF-4. We shall
More informationWHAT IS FIRE? In order to have a fire, there must be three elements: Heat -- enough to make the fuel burn
Emergency Action plan Volunteer employees with first aid and CPR training Designated meeting place First aid kit Eye wash stations Who do you contact? Fire extinguishers WHAT IS FIRE? In order to have
More informationCESCOM 20 - Projected Maintenance Due
Date Average Projected Days Months Scheduled Maintenance Tasks Drawing # / Task # City Mod Lvl Part Number Part Serial No 51211 PHASE 11 051211 LEFT 051208 : L RIGHT 051208 : R 5120B 051200B INSPECT INBOARD
More informationTECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel
CVENTIAL ALARM S Features: Description: The LF-CP Series Fire Alarm Control Panel is manufactured based on advanced technology while maintaining high quality during assembly. It is of solid state circuitry
More informationSTA16 SELECTRONIC ALARM ANNUNCIATORS DESIGN, INSTALLATION AND OPERATING MANUAL STA16
ST-97106N Revised 07-04 Section 25 (00-02-0283) STA16 SELECTRONIC ALARM ANNUNCIATORS DESIGN, INSTALLATION AND OPERATING MANUAL STA16 Certain danger to human safety and to equipment may occur if some equipment
More information2009 HAWKER 4000 RC-22
Experience Matters. 2009 Two USA Owners Since New ADS-B Out Completed OVERVIEW Registration N639RA Two USA Owners Since New Honeywell HAPP Block Point Modifications - ADS-B Out Done PDA Mod 4, Load 20
More information1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.
Issued 2006/08/01 Section 13920 Packaged Fire Pumps and Controllers Page 1 of 7 PART 1 GENERAL 1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1
More informationChapter 26 FIRE PROTECTION
Chapter 26 FIRE PROTECTION 26-Title Page 1 INTENTIONALLY LEFT BLANK 26-Title Page 2 LIST OF EFFECTIVE PAGES Chapter Section Page No. Date 26 26-Title 1 2 26-LOEP 1 2 26-TOC 1 2 26-20 1 July 28, 2008 2
More informationSELECTION GUIDE SELECTION GUIDE. Pressure, Flow & Liquid Level Products for Aerospace & Military Uses
SELECTION GUIDE SELECTION GUIDE Pressure, Flow & Liquid Level Products for Aerospace & Military Uses P R E C I S I O N S E N S O R S Altitude Switches PRECISION SENSORS 50 Seemans Lane Milford, CT 06460
More informationOPEARATING GUIDELINES FOR AERO-252 (Pages 1 to 3 contain general information on CO Guardian. Pages 4 to 6 contain information specific to Aero 252)
OPEARATING GUIDELINES FOR AERO-252 (Pages 1 to 3 contain general information on CO Guardian. Pages 4 to 6 contain information specific to Aero 252) What is Carbon Monoxide? Carbon Monoxide (CO) is a colorless,
More informationMotorised Infrared Optical Beam Smoke Detector. User Guide
Motorised Infrared Optical Beam Smoke Detector User Guide EN 1. General Information 50cm 50cm 8-100m Ensure clear line of sight from Detector to Reflector Mount on solid surfaces (structural wall or girder)
More information2004 CITATION X. Registration: N228DB Serial Number: Asking Price: Make Offer
Registration: N228DB Serial Number: 750-0228 Asking Price: Make Offer AIRFRAME ENGINES ROLLS ROYCE AE 3007C1 Airframe Total Time: 3,185 Landings: 1,485 AVIONICS HONEYWELL Left Engine Right Engine Serial
More informationDYCU-3 AEROSOL FIRE EXTINGUISHER CONTROL UNIT OPERATION MANUAL
DYCU-3 AEROSOL FIRE EXTINGUISHER CONTROL UNIT OPERATION MANUAL DOC: GLT.MAN-136 1 INDEX INTRODUCTION 3 CONNECTIONS 4 OPERATION 5 LINKING 6 TECHNICAL INFO 7 DOC: GLT.MAN-136 2 INTRODUCTION The Dynameco
More informationBP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6
BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6 1. Purpose This policy sets forth requirements for preventing and detecting fires, sounding an alarm, and suppressing fires. Fire protection
More informationCO Guardian LLC Document No E. AIRPORT DRIVE Date: TUCSON, AZ CO Guardian LLC 1951 E. Airport Dr.
1951 E. AIRPORT DRIVE Date: 8-20-2004 CO Guardian LLC 1951 E. Airport Dr. Tucson, AZ 85706 OWNERS MANUAL CARBON MONOXIDE DETECTOR MODEL 452-201 REMOTE UNIT MODEL 452-201 OWNERS MANUAL Page 1 of 22 INTENTIONALLY
More information(2) Various fire sections enclosed by various classes of fire divisions; (3) Arrangement of fire detectors and manual fire alarm stations;
(1979) (Rev.1 1990) (Rev.2 1996) (Rev.3 Jan 2012) Safety features.1 Fire protection and extinction.1.1 General Fire protection arrangements and fire extinguishing systems are to be in accordance with the
More informationNZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL
NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL Document No...G108WO1.DOC Serial No... Issue Date...17 th SEPTEMBER 1999 Software Version...1.4 APPROVED TO: NZS 4512:1997 AS/NZS 3548:1992 Fire Alarm
More informationFA-101U Fire Alarm Control Panel
FA-101U Fire Alarm Control Panel INSTALLATION and OPERATION MANUAL LNOTICE All information, documentation, and specifications contained in this manual are subject to change without prior notice by the
More informationTABLE OF CONTENTS PART 4 - HAND TOOLS AND POWER DRIVEN PORTABLE TOOLS
TABLE OF CONTENTS PART 4 - HAND TOOLS AND POWER DRIVEN PORTABLE TOOLS Page DEFINITIONS...4-1 GENERAL...4-1 CHAIN SAWS...4-3 BRUSH SAWS...4-4 POWDER ACTUATED TOOLS...4-5 PORTABLE CIRCULAR SAWS...4-5 PART
More informationZIOU/230 - MAINS IO INSTRUCTION MANUAL
Description ZIOU/230 - MAINS IO INSTRUCTION MANUAL The Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third party equipment with the Fire Alarm Control panel
More informationCHAPTER 11 HEATING AND VENTILATION
CHAPTER 11 HEATING AND VENTILATION Section Title Page 11.000 Heating and Ventilation...................................... 11.1 11.001 Introduction........................................... 11.1 11.002
More informationSpecial solution KS marine. Kitchen protection system KS marine Fire prevention for galleys
Special solution KS 2000-8 marine Kitchen protection system KS 2000-8 marine Fire prevention for galleys RiskDeep fat fryer fire Safety requirements for passengers and crew are especially high at sea.
More informationCLEANROOM MONITOR CR3A Network - Installation Instructions
CLEANROOM MONITOR CR3A Network - Installation Instructions INTRODUCTION The CR3 Series Cleanroom Monitor, was developed specifically to allow for monitoring of confined spaces with accuracy and reliability.
More informationMotorised Infrared Optical Beam Smoke Detector. User Guide
Motorised Infrared Optical Beam Smoke Detector User Guide EN 1. General Information 50cm 50cm 8-100m Ensure clear line of sight from Detector to Reflector Mount on solid surfaces (structural wall or girder)
More informationAPS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES
APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES POWER SUPPLY AND BATTERY CHARGER AC AND DC STATUS INDICATORS ENOUGH POWER TO SUPPORT UP TO 3 MAGLOCKS OR ELECTRIC STRIKES PLUS REQUIRED
More information