Certificate of Compliance

Size: px
Start display at page:

Download "Certificate of Compliance"

Transcription

1 FF0002 Certificate of Compliance Certificate: Issued to: Siemens Canada Limited 1954 Technology Drive Peterborough, ON K9J 7B1 Canada Attention: Mr. Lee Rogers The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only K Atkins Issued by: K. Atkins PRODUCTS CLASS PROCESS CONTROL EQUIPMENT CLASS PROCESS CONTROL EQUIPMENT (Certified to U.S. Standards) External Display and Adjustment Unit, Model LGRI; supplied from SIEMENS sensor only, optional heating, supplied at 24Vdc (+5%), 1.7 W; Enclosure CSA type 4X, 6P; Ambient Temperature -40 C to +80 C (without display and adjustment module), -15 C to +70 C (with display and adjustment module), -40 C to +70 C (with heated display and adjustment module); Notes: 1. To be supplied by a Class 2 or Limited Energy Source in accordance with CSA Rated: Pollution Degree 2, Overvoltage Category I. 3. Environmental Conditions: 5000 m max DQD 507 Rev Page 1

2 CLASS PROCESS CONTROL EQUIPMENT For Hazardous Locations CLASS PROCESS CONTROL EQUIPMENT For Hazardous Locations Certified to US Standards Class I, Division 2, Groups A, B, C and D; Class II, Division 2, Groups E, F and G; Class III Class I, Zone 2 A/Ex na IIC Gc Model LGRI series Indication and Adjustment Unit; supplied from SIEMENS sensor only, optional heating, supplied at 24Vdc (+5%), 1.7 W; Enclosure CSA type 4X, 6P; Ambient Temperature -40 C to +80 C (without display and adjustment module), -15 C to +70 C (with display and adjustment module), -40 C to +70 C (with heated display and adjustment module); Permissible temperature -20 C C -40 C C -40 C C Model LGRI.CAIabcdef, where: a = Housing: K, A or V b = Protection: I or N c = Cable entry: M, N or D d = Indicating adjusting module: X, A or H e = Mounting: A, C, D, E or F f = Certificates: X or M Class I, Division 1, Groups A, B, C and D; Class II, Division 1, Groups E, F, G; Class III Ex d IIC Gb Class I, Zone 1 A/Ex d IIC Gb Model LGRI series Indication and Adjustment Unit. Enclosure Type 4X; IP66. Permissible temperature -50 C C -40 C C -40 C C Model LGRI.CEIabcdef, where : a = Housing: A or V b = Protection: N c = Cable entry: M, N or D d = Indicating adjusting module: X or A e = Mounting: A, C, D, E or F f = Certificates: X or M DQD 507 Rev Page 2

3 CLASS PROCESS CONTROL EQUIPMENT - Intrinsically Safe, Entity - For Hazardous Locations CLASS PROCESS CONTROL EQUIPMENT - Intrinsically Safe, Entity - For Hazardous Locations Certified to US Standards Class I, Division 1, Groups A, B, C and D; Class II, Division 1, Groups E, F, G; Class III Ex ia IIC Ga, Gb Class I, Zone 0 A/Ex ia IIC T6 Ta = 60 C Model LGRI series Indication and Adjustment Unit. Enclosure Type 4X, IP66. Intrinsically safe with entity parameters Vmax = 6.4 V, Imax = ma, Pi = 332 mw, Ci = 0 µf, Li = 0 when connected to the Comm Port of a SIEMENS sensor per control drawing EPL Ga installation: Permissible temperature -20 C C -20 C C -20 C C EPL Gb installation: Permissible temperature -40 C C -40 C C -40 C C Model LGRI. CaIbcdefg where a = Approval: C or O b = Housing: K, A or V c = Protection: I or N d = Cable entry: M, N or D e = Indicating adjustment module: X or A f = Mounting: A, C, D, E or F g = Certificates: X or M APPLICABLE REQUIREMENTS CAN/CSA-C22.2 No UL Std. No (3 rd Edition) CSA Std. C22.2 No. 94-M91(R 2006) CSA Std. C22.2 No (R2009) - Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use, Part 1: General Requirements - Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use - Part 1: General Requirements - Special Purpose Enclosures - Enclosures for Use in Class II Groups E, F and G Hazardous DQD 507 Rev Page 3

4 Locations CSA Std. C22.2 No. 30 M1986 (R 2003) - Explosion-Proof Enclosures for Use in Class Hazardous Locations CSA Std. C22.2 No (R 2006) - Intrinsically Safe and Non-Incendive Equipment for Use in Hazardous Locations CSA Std C22.2 No. 213-M1987 (R 2004) - Non-Incendive Electrical Equipment for Use in Class I, Division 2 Hazardous Locations CAN/CSA Std. C22.2 No :12 - Electrical apparatus for explosive gas atmospheres - Part 0: General requirements CAN/CSA Std. C22.2 No :12 - Electrical apparatus for explosive gas atmospheres - Part 1: Flameproof Enclosure d CAN/CSA Std. C22.2 No :12 - Electrical apparatus for explosive gas atmospheres - Part 11: Intrinsic safety "i" CAN/CSA Std. C22.2 No :12 - Electrical Apparatus for Explosive Gas Atmospheres--Part 15: Type of Protection "n" UL Std. No. 913 (4th Ed) - Intrinsically Safe and Associated Apparatus For Use In Class I, II, and III, Division 1, Hazardous (Classified) Locations ANSI/ISA Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Division 1 and 2 Hazardous (Classified) Locations UL Std. No. 50 (Edition 10) - Enclosures for Electrical Equipment UL Std. No. 1203, Ed 4 (2006) - Explosion-Proof and Dust-Ignition-ProofElectrical Equipment for Use in Hazardous (Classified) Locations ANSI/UL (5th Ed. 2009) - Explosive Atmospheres Part 0: Equipment - General Requirements ANSI/UL (6th Ed. 2009) - Explosive Atmospheres Part 1: Equipment Protection by Flameproof Enclosures d ANSI/UL (5th Ed. 2009) - Explosive Atmospheres Part 11: Equipment Protection by Intrinsic Safety "i" ANSI/ISA (5th Ed. 2009) - Electrical Apparatus for Explosive Atmospheres: Part 15: Electrical Apparatus with Type of Protection n MARKINGS The manufacturer is required to apply the following markings: Products shall be marked with the markings specified by the particular product standard. Products certified for Canada shall have all Caution and Warning markings in both English and French. DQD 507 Rev Page 4

5 Additional bilingual markings not covered by the product standard(s) may be required by the Authorities Having Jurisdiction. It is the responsibility of the manufacturer to provide and apply these additional markings, where applicable, in accordance with the requirements of those authorities. The products listed are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US (indicating that products have been manufactured to the requirements of both Canadian and U.S. Standards) or with adjacent indicator 'US' for US only or without either indicator for Canada only. (1) Company's name, trademark, or the CSA Master Contract Number (adjacent the CSA Mark). (2) Catalogue / Model designation. (3) Complete electrical rating (amps, hertz, and volts). (4) Date code / Serial number traceable to month and year of manufacture. (5) Hazardous Location designations. (6) Optional markings: Class I, Zone 0/1, IIC, T6-1 (as applicable) (7) The symbol "A/Ex ia" (as applicable) (8) The words "INTRINSICALLY SAFE" (as applicable) (9) Install as per Installation Control Drawings (as applicable) (10) Temperature code with derating for process temperature (may appear in Instruction Manual or in Safety Manual provided with the Instruction Manual. (11) Maximum ambient 60 C (12) Maximum Working Pressure (13) CSA Mark, with the C/US indicator; The products listed are eligible to bear the CSA Mark with adjacent indicators 'C' and 'US' for Canada and US. (14) Single Seal (15) The following cautions: WARNING - A SEAL SHALL BE INSTALLED WITHIN 18 inch OF THE ENCLOSURE WARNING - DO NOT OPEN WHEN AN EXPLOSIVE GAS ATMOSPHERE IS PRESENT WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR INTRINSIC SAFETY WARNING AVOID ELECTROSTATIC CHARGE REQUIRED METHOD OF MARKING: The marking shall be permanent, such as a 0.5-mm thick metal nameplate secured by drive pins or screws in bottomed holes, cast, etched, or engraved, or CSA Accepted adhesive-type nameplates, manufactured by Brady, P/N B-423 or Schreiner Colour Laser Film Black SA (39-06), P/N Polyscript Carbo ACE SA, mounted to bare stainless steel, Valox 357 Polymer or painted aluminum. The manufacturer is required to apply the following markings: Products shall be marked with the markings specified by the particular product standard. Products certified for Canada shall have all Caution and Warning markings in both English and French. Additional bilingual markings not covered by the product standard(s) may be required by the Authorities Having Jurisdiction. It is the responsibility of the manufacturer to provide and apply these additional markings, where applicable, in accordance with the requirements of those authorities. DQD 507 Rev Page 5

6 The following markings appear on the product: 1. Company s identification (company name and/or Master Contract and/or registered trade name); 2. Marking on the unit that indicates the manufacturing location if the equipment is manufactured at more than one factory location.model designation; 3. Electrical rating; 4. Date of manufacture: Month and year of manufacture or date code. If a serial number is used instead of date of manufacture, a record of serial numbers shall be kept traceable to date of manufacture. (Not related to date of sale). 5. The products listed are eligible to bear the CSA Mark shown with adjacent indicators C and US for Canada and US, or with adjacent indicator US for US only, or without either indicator for Canada only:, or, or. Marking Method: The above markings are made via silk screening, die stamping, moulding, or on CSA certified or UL recognized adhesive nameplate material compatible with the surface used, or other equivalent permanent means that can pass the label rub test. DOCUMENTATION: Equipment is accompanied by the following documentation. General: Technical specifications, instructions for use and details of where technical assistance may be obtained if required. Equipment Ratings: This includes equipment supply, description of I/O connections and operating environmental conditions. 1. Pollution degree 2; 2. Installation category I; 3. Altitude 5000m; 4. Electrical supply from SIEMENS sensor only, optional heating, supplied at 24Vdc (+5%), 1.7 W 5. Temperature -40 C to +80 C (without display and adjustment module), -15 C to +70 C (with display and adjustment module), -40 C to +70 C (with heated display and adjustment module; Equipment Installation: This includes instructions for Assembly and mounting; location requirements. PERMANENTLY CONNECTED EQUIPMENT requires the special considerations to satisfy the CEC, NEC and the Canadian deviations in the standard, including overcurrent and fault protection as required. DQD 507 Rev Page 6

7 Equipment Operation: This includes explanations of operating controls and warning symbols used. 1. List of accessories which meet the manufacturer s specifications to be used; 2. Guidance on how to determine that the equipment is functioning correctly; 3. Statement that, if the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Equipment Maintenance and Service: This includes instructions for preventative maintenance, inspection and cleaning, replacement of parts, etc. DQD 507 Rev Page 7

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296

More information

Certificate of Compliance

Certificate of Compliance FF0002 Certificate of Compliance Certificate: 70009779 Issued to: Pepperl+Fuchs GmbH Lilienthalstrasse 200 Mannheim, 68307 GERMANY Attention: Martin Holdefer The products listed below are eligible to bear

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70033893 (166720) Issued to: WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Str 30 Klingenberg, 63911 GERMANY Attention: Uwe Schmidt The products listed below

More information

Certificate of Compliance

Certificate of Compliance FF02 Certificate of Compliance Certificate: 70068210 Issued to: Cascade Technologies Ltd Glendevon House, Castle Business Park, Stirling, Scotland. UNITED KINGDOM FK9 4TZ Attention: Mr M Douglas. The products

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2185148 (217005) Issued to: RAE Systems, Inc. 3775 North First St San Jose, California 95134 USA Attention: James Pan The products listed below are eligible to bear

More information

for CE 134 CCSAUS certificate Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title page EN

for CE 134 CCSAUS certificate Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title page EN Title page CCSAUS certificate: EN 70034691 for EX Meggitt SA Route de Moncor 4 PO Box 1616 CH - 1701 Fribourg Switzerland CCSAUS certificate 70034691 www.meggittsensingsystems.com www.vibro-meter.com THIS

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1469131 (LR 103134) Master Contract: 184981 Issued to: Industrial Monitoring Instr. (IMI) A Div. of PCB Piezotronics, Inc. 3425 Walden Ave Depew, NY 14043 USA Attention:

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70067850 Date Issued: July 28, 2017 Issued to: Otis Instruments, Incorporated 301 S. Texas Ave. Bryan, Texas, 77803 USA Attention: Nicholas Sandera The products listed

More information

Certificate of Compliance

Certificate of Compliance FF0002 Certificate of Compliance Certificate: 2385571 Project 2447891 Issued to: Mine Safety Appliances 1000 Cranberry Woods Drive Cranberry Township, PA 16066 USA Issued by: Jocelyn Jens Product Group

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1238566 Issued to: Rosemount Analytical Inc. Solon Research & Development Ctr 6565-P Davis Industrial Pkwy Solon, OH 44139 USA Attention: Dana Crowley The products

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2557738 Master Contract: 256526 Issued to: Bartec Varnost d.o.o Cesta 9 avgusta 59 Zagorje ob Savi, 1410 Slovenia Attention: Janez Gajski The products listed below

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70000097 Project: 70125347 Issued to: Thermo Engineering S.r.l Via Giuseppina, 19 26030 Malagnino (CR) Italy Attention: Mr. BOZZETTI The products listed below are

More information

ccsaus certificate: for GSI 127 Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title Page

ccsaus certificate: for GSI 127 Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title Page Title Page ccsaus certificate: EN 70001999 for EX Meggitt SA Route de Moncor 4 PO Box 1616 CH - 1701 Fribourg Switzerland ccsaus certificate 70001999 www.meggittsensingsystems.com www.vibro-meter.com THIS

More information

Certification Supplement Manual

Certification Supplement Manual PROCESS ANALYSERS SERVOTOUGH Oxy Gas Analyser Certification Supplement Manual Part Number: 01910008B Revision: 9 Language: UK English This page intentionally blank SERVOTOUGH Oxy Certification Supplement

More information

Certification Supplement Manual

Certification Supplement Manual PROCESS ANALYSERS SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 2 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EC DECLARATION OF CONFORMITY

More information

Certificate of Compliance

Certificate of Compliance FF0002 Certificate of Compliance Certificate: 2708418 Issued to: Gems Sensors Inc. 1 Cowles Road Plainville, CT 06062 USA Attention: Mr. Philip I. Draper The products listed below are eligible to bear

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1182963 (066027_0_000) Issued to: WIKA Instruments Ltd. 3103 Parsons Rd Edmonton, Alberta T6N 1C8 CANADA Attention: Robert Woo The products listed below are eligible

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1563164 Issued to: Metal Samples Company, A Div. of Alabama Specialty Products, Inc. 152 Metal Samples Rd PO Box 8 Munford, Alabama 36268 USA Attention: Bala Palanisamy

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1655492 (219995) Issued to: R.C. Systems Co., Inc. 8621 Hwy 6 Hitchcock, Texas 77563 USA Attention: Roger Carter The products listed below are eligible to bear the

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2325079 Issued to: Cooper Crouse Hinds GmbH Neuer Weg Nord 49 69412 Eberbach Germany Attention: Mr Günther The products listed below are eligible to bear the CSA

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2007104 Master Contract: 223077 Issued to: Purge Solutions 2201 North Highway 35 Bypass Suite C Alvin, TX 77511 USA Attention: Wallace Trochesset The products listed

More information

Certificate of Compliance

Certificate of Compliance FF0002 Certificate of Compliance Issued to: Exheat Ltd. Threxton Road Industrial Estate Watton Thetford Norfolk, IP25 6NG UNITED KINGDOM Attention: James Pettman The products listed below are eligible

More information

Certification Supplement Manual

Certification Supplement Manual SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 5 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EU DECLARATION OF CONFORMITY 3 EUROPEAN

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1055868 (LR 44092) Master Contract: 152450 Issued to: Micro Motion Incorporated 7070 Winchester Cir Boulder, CO 80301 USA Attention: Ray C. Stengl The products listed

More information

Certificate of Compliance

Certificate of Compliance FF0002 Certificate of Compliance Certificate: 70044220 Issued to: Cascade Technologies Limited Glendevon House Castle Business Park Stirling FK9 4TZ UK Attention: Mr. Marcus Douglas The products listed

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Issued to: GE Intelligent Platforms 240 The Village Butterfield Business Park Bedfordshire, Luton LU2 8DL United Kingdom Attention: John Purdy The products listed below are eligible

More information

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma, User s Manual YTA Series Temperature Transmitters [Style: S3] Manual Change No. 10-008 Please use the attached sheets in the following manuals when the product is with /KU2 option and EN60000 Series based

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output

More information

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O****** Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O****** CSA 14.2662675 Ex ia IIC T6 Ga, Gb 0044 Document ID: 48924 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical

More information

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74 AM54 Instruction Bulletin North American Installation Addendum Document Number PN25016 Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

More information

User s Manual YTA610 and YTA710 NEPSI Certification

User s Manual YTA610 and YTA710 NEPSI Certification User s Manual YTA60 and YTA70 NEPSI Certification [Option code: /NS, /NS5 and /NF] st Edition . INTRODUCTION Thank you for purchasing the YTA60 and YTA70 Temperature transmitters. This manual contains

More information

Field Certification Certificate of Compliance

Field Certification Certificate of Compliance 2 Field Certification Certificate of Compliance Certificate: 2415870 Master Contract: 225996 Project: 2415870 Issued to: SpectraSensors, Inc. 11027 Arrow Route Rancho Cucamonga, CA 91730 USA Attention:

More information

Annubar Flowmeter Series

Annubar Flowmeter Series Reference Manual Appendix B Approvals Annubar Flowmeter Series Hazardous Locations Installations.................. page B-1 Rosemount 3051SFA Product Certifications.......... page B-1 Rosemount 3095MFA

More information

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates Note: While this material was originally prepared for presentation in February 1999, it has been updated to reflect the evolving technical requirements now applicable as of April 2003. UL Topic III Converting

More information

An Urgent Bulletin from CSA Group

An Urgent Bulletin from CSA Group An Urgent Bulletin from CSA Group Hazardous Locations Products No. 28 (Supersedes Electrical Certification Notice No. 544A) Date: January 3, 2018 See Attachment 1 for Effective Dates. See Attachment 1

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2613175 Master Contract: 162874 Project: 2613175 Date Issued: April 18, 2013 Issued to: Fujitsu Technology Solutions GmbH Product Compliance Center Buergermeister-Ulrich-Str

More information

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter PD685 Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter Actual Size Digits C US Intrinsically Safe 3½ Digits LARGE DISPLAY NEMA 4, Type 4X, IP67 Loop-Powered Field-Mount Process Meter 4-20 ma

More information

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C PSD1001C INSTRUCTION MANUAL SIL 3 SIL 2 IIB Group Power Supply for Hazardous Area Equipment DINRail Model PSD1001C PSD1001C SIL 3 SIL 2 IIB Group Power Supply for hazardous Area Equipment ISM006510 General

More information

Operating Instructions Edition 02/2007

Operating Instructions Edition 02/2007 Operating Instructions Edition 02/2007 Temperature Transmitter 7NG3214 with PROFIBUS PA 7NG3215 with FOUNDATION Fieldbus sitrans Introduction 1 General safety notes 2 SITRANS T Temperature transmitter

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm

More information

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses. General information 1 Marking of the degree of protection 2 SITRANS T SITRANS T Explosion protected temperature sensor Operating Instructions Range of uses 3 Installation 4 Assembly and disassembly 5 Commissioning

More information

Tank Gauging System Special Safety Instruction

Tank Gauging System Special Safety Instruction Tank Gauging System www.rosemount-tg.com Rosemount TankRadar REX Table of Contents Contents SPECIAL SAFETY INSTRUCTION........................ 1-1 1. GENERAL REQUIREMENTS....................... 1-2 1.1

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 5 mm flush Usable up to SIL2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching element

More information

CONTROL BE MADE CHANGES MAY NOT. Page 1

CONTROL BE MADE CHANGES MAY NOT. Page 1 HI 6020IT and HI 6020JB US & Canada Hazardous Locations User Guide (Class I, II, III, Division 1, Class I, Zone 0 and Zone 20) Hardy Process Solutions Document Number: : 0596-0352-01 REV A CONTROL LLED

More information

UL HAZARDOUS LOCATIONS SERVICES

UL HAZARDOUS LOCATIONS SERVICES UL HAZARDOUS LOCATIONS SERVICES The international preference in hazardous locations certification for over 100 years ul.com/hazloc Explosive Gas Atmospheres Class I Division S Includes flammable gases,

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 8 mm non-flush Stainless steel housing Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 8 mm

More information

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt Airo Wireless Intrinsically Safe White Paper Written By: David Schmitt Intrinsically Safe Cell Phone/Smartphone/PDA Intrinsically Safe (IS) is a protection certification for safe operation with electronic

More information

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

Rosemount 752 FOUNDATION Fieldbus Remote Indicator Rosemount 752 FOUNDATION Fieldbus Remote Indicator Product Data Sheet 00813-0100-4377, Rev FA Two-wire segment powered device Displays up to eight values Link Master Capability Optional PID, Characterizer,

More information

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm 0102 Model Number Features 8 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-d Edition 09/208 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4

More information

FLASHLIGHT ANSI STANDARDS

FLASHLIGHT ANSI STANDARDS FLASHLIGHT ANSI STANDARDS While Pelican was one of the first manufacturers to use quantifiable test procedures, the need was recognized to develop a common language that customers could use to select the

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate IECEx

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2595099 (LR 7189-177) Master Contract: 164196 Project: 2697346 Date Issued: January 28, 2014 Issued to: Tyco Electronics Corporation 2901 Fulling Mill Rd Mail Stop

More information

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm 0102 Model Number Features 4 mm non-flush Accessories BF 12 Mounting flange, 12 mm Technical Data specifications Switching element function NAMUR, NO Rated operating distance s n 4 mm Installation non-flush

More information

D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410

D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410 FIELDBUS INTRINSICALLY SAFE CONCEPT (FISCO) APPROVAL FISCO allows interconnection of intrinsically safe apparatus to associated apparatus not specially examined in such combination. The criteria for interconnection

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 15 mm Installation non-flush Assured operating distance s a 0...

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-nA Edition 08/207 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4

More information

Ar-Mite TM Low Flow Armored Flowmeter

Ar-Mite TM Low Flow Armored Flowmeter Data Sheet Brooks Ar-Mite TM MT 3750C Ar-Mite TM Low Flow Armored Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter with Transmitter or Inductive Alarm

More information

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations INSTRUCTION MANUAL E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

SmartPower Solutions. Quick Start Guide , Rev CA March 2015 SmartPower Solutions 00825-0100-4701, Rev CA NOTICE This guide provides basic guidelines for the SmartPower family of products. It does not provide instructions for detailed configuration, diagnostics,

More information

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following

More information

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon INSTRUCTION MANUAL Minialite Intrinsically Safe Round LED This instruction sheet describes installations which conform to EN60079:Part14:2008 Electrical Installation in Hazardous Areas. When designing

More information

standards: standards:

standards: standards: INSTRUCTION MANUAL D2xB1LD2 LED Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING HAZARD

More information

Rosemount 3200HP. ph Sensors. Instruction Manual LIQ-MAN-3200HP Rev. G April 2017

Rosemount 3200HP. ph Sensors. Instruction Manual LIQ-MAN-3200HP Rev. G April 2017 Rosemount 3200HP ph Sensors Instruction Manual LIQ-MAN-3200HP Rev. G April 2017 hasgkas Essential Instructions Read this page before proceeding! Emerson designs, manufactures and tests its products to

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

DB5 Intrinsically Safe Sounder Type DB-5

DB5 Intrinsically Safe Sounder Type DB-5 Operating Instructions RTK Instruments Limited DB5 Intrinsically Safe Sounder Type DB-5 Description The DB5 Sounder is a strong, lightweight warning sounder, CENELEC certified to Ex II 1G EExia IIC T4

More information

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017 Rosemount 214C Sensor 00825-0400-2654, Rev AF NOTICE This guide provides basic guidelines for Rosemount 214C Sensor models. If the sensor was ordered assembled to a temperature thermowell or transmitter,

More information

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Manual Change No Yokogawa Electric Corporation

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Manual Change No Yokogawa Electric Corporation User s Manual EJA Series Differential Pressure and Pressure Transmitters Manual Change No. 12-004 For the models EJA and EJA-A series with option code /KF21, /KU21, /KU22 or /KN26, please use this manual

More information

Rosemount 752 Fieldbus Remote Indicator

Rosemount 752 Fieldbus Remote Indicator Product Data Sheet Rosemount 752 Rosemount 752 Fieldbus Remote Indicator ROSEMOUNT 752 DELIVERS: Two-wire segment powered device Displays up to 8 values Link Master Capability Optional PID, Characterizer,

More information

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012 Start Step 1: Physical Installation Step 2: Verify Operation Disposal/Recycling of Depleted Power Modules Product Certifications EC Declaration of Conformity End 00825-0100-4701[ 2012 Rosemount Inc. All

More information

4) Intrinsic Safety Certification

4) Intrinsic Safety Certification INSTRUCTION MANUAL Minialert Intrinsically Safe Round Combined Unit Section Volume Control Tone Generator S2 S3 Tone Selection Switches Fig 1 Simplified block diagram The combined unit is CE marked for

More information

Instructions. Explosion Proof Smoke Detector U Rev: 9/

Instructions. Explosion Proof Smoke Detector U Rev: 9/ Instructions Explosion Proof Smoke Detector U0. Rev: 9/ 9-7 Table of Contents OVERVIEW... FEATURES... BENEFITS... SPECIFICATIONS... OPERATION... Warm Up... Outputs... Integral Wiring Compartment... LED...

More information

CERTIFICATE OF COMPLIANCE HAZARDOUS LOCATION ELECTRICAL EQUIPMENT PER CANADIAN REQUIREMENTS

CERTIFICATE OF COMPLIANCE HAZARDOUS LOCATION ELECTRICAL EQUIPMENT PER CANADIAN REQUIREMENTS j,!'. ;.'. FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 7624300 F: 781-762-9375 www.fmapprovals.com M('Ii/J(' (!li/w FM (i/(li1(// Groii/) CERTIFICATE OF COMPLIANCE

More information

Hazardous Area Classifications and Protections

Hazardous Area Classifications and Protections Hazardous Area Classifications Product Bulletin Hazardous Area Classifications and Protections The intent of this document is to provide a broad overview of hazardous area classifications and the types

More information

OPTIBAR DP 7060 Supplementary Instructions

OPTIBAR DP 7060 Supplementary Instructions OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,

More information

RMA 3000 Remote Meter Assemblies

RMA 3000 Remote Meter Assemblies RMA 3000 Remote Meter Assemblies User Manual Doc. No.: 34-ST-25-19 Release: 8 Last Revision Date: July 2017 Honeywell Process Solutions Notices and Trademarks Copyright 2017 by Honeywell International

More information

PESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard

PESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard Persons concerned: Experienced professional electricians as per EU Directive

More information

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations INSTRUCTION MANUAL D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations synchronization requirements of UL1971 & UL1638 / CAN/ULCS526. 2.2 NEC & CEC Class / Division Ratings for US / Canada

More information

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016 Rosemount 148 Temperature Transmitter 00825-0100-4148, Rev GA NOTICE This guide provides basic guidelines for the Rosemount 148. It does not provide instructions for detailed configuration, diagnostics,

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 50 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 50 mm Installation non-flush Output polarity NAMUR

More information

General Specifications

General Specifications General Specifications GS 12A01A02-72E Model FLXA 21 2-Wire Analyzer PROFIBUS PA Communication General PROFIBUS is a vendor-independent and open fieldbus based on the international standard IEC61158 and

More information

Rosemount 3900/3900VP

Rosemount 3900/3900VP Rosemount 3900/3900VP General Purpose ph/orp Sensor Instruction Manual LIQ-MAN-3900 Rev. G April 2017 hasgkas Essential Instructions Read this page before proceeding! Emerson designs, manufactures, and

More information

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Installation Manual. 1. Introduction. 2. Handling Cautions. 3.

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Installation Manual. 1. Introduction. 2. Handling Cautions. 3. User s Manual EJA Series Differential Pressure and Pressure Transmitters Installation Manual 1. Introduction 1.1 For Safe Use of Product...2 1.2 Warranty...3 1.3 ATEX Documentation...4 2. Handling Cautions

More information

Instructions. Det-Tronics SmokeWatch Explosion Proof Smoke Detector U Rev: 3/

Instructions. Det-Tronics SmokeWatch Explosion Proof Smoke Detector U Rev: 3/ Instructions Det-Tronics SmokeWatch Explosion Proof Smoke Detector U5015 Rev: 3/17 95-8723 Table of Contents OVERVIEW...1 FEATURES...1 BENEFITS...1 SPECIFICATIONS...2 OPERATION...3 Warm Up...3 Outputs...3

More information

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC EUROPEAN ATEX DIRECTIVE > European Directive 2014/34/EU ATEX Directive 2014/34/EU is a "new approach" directive that applies to protective systems against explosions as well as all equipment used in or

More information

Quick Start Guide For the

Quick Start Guide For the A Leader in Level Measurement Quick Start Guide For the Universal IV Lite and Universal IV Pro Model Transmitters 2-Wire RF Admittance / Capacitance Level Measurement System with HART Protocol For Assistance

More information

Rosemount 248 Temperature Transmitter

Rosemount 248 Temperature Transmitter Product Data Sheet November 2013 00813-0100-4825, Rev KA Rosemount 248 Temperature Transmitter Basic temperature transmitter offers a reliable solution for temperature monitoring points transmitter design

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70000287 (085005_0_000) Issued to: steute Schaltgeräte GmbH & Co. KG Brueckenstrasse 91 Loehne, 32584 GERMANY Attention: Patrick Keilwerth The products listed below

More information

Rosemount 2088, 2090P, and 2090F Pressure Transmitters

Rosemount 2088, 2090P, and 2090F Pressure Transmitters April 2013 Rosemount 2088 and 2090 Rosemount 2088, 2090P, and 2090F Pressure Transmitters with 4-20 ma HART and 1-5 Vdc HART Low Power Protocol Start Step 1: Mount the Transmitter Step 2: Set the Jumpers

More information

PEPPERL+FUCHS GmbH

PEPPERL+FUCHS GmbH Comfort series 1.5 mm embeddable M8x1 4 25 16 13 LED Switching element function NAMUR NC Rated operating distance s n 1,5 mm Installation embeddable Assured operating distance s a 0... 1,215 mm Reduction

More information

Technical Information

Technical Information Technical Information Explosion Protection Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Tel.: 81-422-52-5634 Fax.: 81-422-52-9802 Copyright May 2004 (YK) 15th Edition

More information

Declaration of conformity

Declaration of conformity File: ATEX Manoswitch DoC 2017-10-20 Rev: 2017-10-20 id: mk Declaration of conformity The products listed in Appendix B, meet the requirements for a simple apparatus given by the standards listed below.

More information

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS SITRANS LR 400 Quick Start Manual This manual outlines the essential features and functions of the SITRANS LR 400

More information

Guide for hazardous areas

Guide for hazardous areas Guide for hazardous areas 1 Hazardous areas definitions 2 Gas and dust s 3 Temperature classifications 4 Common flammable gases, vapours and dust types 5 Protection concepts ATEX and IECEx 6 Protection

More information

GETTING STARTED GUIDE NI DIO, 5 V/TTL, Bidirectional, 7 μs

GETTING STARTED GUIDE NI DIO, 5 V/TTL, Bidirectional, 7 μs GETTING STARTED GUIDE NI 9403 32 DIO, 5 V/TTL, Bidirectional, 7 μs This document explains how to connect to the NI 9403. Note Before you begin, complete the software and hardware installation procedures

More information

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS Hazardous Areas - EXPLOSIONPROOF SOLENOIDS SOME HISTORY The classification of hazardous areas into zones established the level of protection required for electrical equipment installed in explosive gas

More information