1 GE Sensing & Inspection Technologies Modus Model DA General Eastern Low Differential Alarm Controller The Modus Model DA is a controller designed for the monitoring of low differential pressures. It combines in one enclosure a low pressure transducer, a digital display, and up to two alarms (see Figure 1). A 4 to 20 ma output is also available as an option. The Modus Model DA controller is typically used for the monitoring of clean room pressures, duct static and velocity pressures; as well as filter differential, draft, fume hood, and other low pressure applications. The pressure sensing element is a differential capacitance cell for pressure measurements ranging from 0.1 in to 5.0 in (2.5 mm to 127 mm) of water (25 Pa to 1.0 kpa), or a piezoresistive (silicon) sensor for pressures from 5 in (127 mm) of water to 30 PSI (1.0 kpa to 200 kpa). The display section has three 1/2 digits with bright, easy to read LEDs. The display is factory-calibrated to read in engineering units. The alarm section is offered with one or two alarms. Each alarm may be ordered with a relay or transistor output. Each setpoint is displayed by pressing a button on the front panel and its setting is changed by means of a multiturn potentiometer also accessible on the front panel. Figure 2 shows a typical deadband diagram for an alarm energizing on falling pressure. When the momentary push button is pressed, the reading on the display is the position of the midpoint of the deadband. When the potentiometer is turned all the way counterclockwise, the lowest reading appearing on the display is half the deadband. Barb fittings and pluggable terminals with screw clamps are provided at the rear for quick and simple field connections. Hi Lo transducer Setpoints 1 2 Alarms Outputs 1 2 g Power VAC, In Figure 1 Block Diagram Power supply display
2 Model DA Specifications 3.93 in (99.8 mm) On Output state *=Deadband 1* 2 1* 2 1* 2 Off 0 Minimum setpoint Setpoint Screw clamp (2 places) Figure 2 Deadband Diagram 0.30 in (7.6 mm) General Accuracy of Reading Standard ±1% of span one digit (including non-linearity and hysteresis) 3.78 in (96 mm) Top View Setpoint Accuracy ±0.2% of span one digit (including repeatability) Modus Inches of water Setpoint Power Requirements 21 to 32 VAC, 50/60 Hz, 105 to 135 VAC, 50/60 Hz or 210 to 265 VAC, 50/60 Hz Power Consumption 2.5 VA Electrical Connections Non-interchangeable power and alarm plugs with #4-40 screw clamps; wire range is 14 to 22 AWG Warmup Time Five minutes to rated accuracy Alarm receptacle (plug not shown) Alarm1 Front View J3 A Alarm2 J1 B AC Power Rear View 5.72 in (145 mm) 5.28 in (134 mm) 0.25 in (6 mm) maximum panel thickness HI LO 0.19 in (4.75 mm) OD pressure fittings AC power receptacle (plug not shown) 1.89 in (48 mm) 1.67 in (42.5 mm) Side View 3.62 in (92 mm) / 3.65 in (92.8 mm) Plug with #4-40 screw clamp wire range: AWG 1.77 in (45 mm) / 1.8 in (45.6 mm) Panel cutout (per DIN standard 43700) Modus Model DA dimensions
3 Transmitter Measures differential, gage pressure or vacuum Medium Air or inert gases Standard Ranges See table A for English units and metric units Maximum Safe Momentary Overpressure See table A Zero and Span Adjustments 15-turn potentiometers accessible behind red front filter Port Connections 3/16 in (4.75 mm) diameter suitable for 1/8 in or 5/32 in ID Tygon or polyurethane tubing; 1/4 in OD polyethylene tubing. Air filter at both ports Display Display Three 1/2 digits, seven segments, orange-red LEDs, 0.56 in (14.2 mm) high, decimal point factoryprogrammable to four positions ( ) Conversion Rate Three readings/second Polarity Automatic, no positive sign, negative sign Overrange Indication Beyond 1999 display shows 1 Alarms Number of Alarms One or two alarms Setpoint Adjustment 15-turn potentiometer accessible through hole in front filter Setpoint Display By pressing momentary push button in front of controller Deadband Factory set at 5% of range to prevent output chatter in most applications Output Each alarm is available with either: A) SPDT (One form C) electromechanical relay; contacts rated at 5 A 30 VDC 120 VAC, or 4 A at 240 VAC resistive Contact material is gold overlay Isolation between contacts and coil is 2000 VAC one minute B) Transistor (NPN with open collector) rated at: 40 VDC off-state voltage 120 ma DC on-state current when using an external power supply 40 ma per alarm when using the internal 5 VDC supply (consult factory for higher currents) 0.4 V saturation voltage at 100 ma Internal diode to absorb transients when the internal 5 VDC supply is connected to inductive loads Zero and Span Adjustments 15-turn potentiometers accessible behind red front filter
4 Environmental Operating Temperature 32 F to 125 F (0 C to 52 C) Storage Temperature -40 F to 185 F (-40 C to 85 C) Relative Humidity 0 to 90% non-condensing Effect of Temperature ±0.03%/ F reading (±0.05%/ C reading), ±0.005%/ F (±0.01%/ C) setpoint Physical Dimensions 1/8 DIN case (see drawing) Case Material Glass-reinforced NORYL rated UL94V-1 Weight 1.0 lb (454 g) Offset If the controller must operate when a reversal of pressure occurs, then an offset must be specified. To order a controller with offset zero, estimate the maximum positive pressure excursion needed and select the appropriate pressure range from Table A. Then estimate the maximum negative pressure excursion. If it is about equal to the positive excursion, specify B offset. If the negative excursion is less than half of the positive excursion, specify an A offset. Alarm Outputs R Electromechanical relay T Transistor, NPN with open collector (specify if external power supply is used) The above alarms can be configured at the factory to energize on rising or falling pressure. To specify the logic, add the following letter after the alarm type: R Energizing on rising pressure F Energizing on falling pressure For example: Alarm one is selected with a transistor energized on falling pressure, the ordering code is TF. Alarm two is a relay energized on rising pressure, the code would be TR.
5 Wiring Diagrams Standard Ranges English Units Code (1) Range Displayed Resolution Maximum Units (2) Overpressure 01E 0 to 0.1 inh in 5 in 02E 0 to 0.2 inh in 5 in 04E 0 to 0.5 inh in 5 in 05E 0 to 1.0 inh in 20 in 06E 0 to 2.0 inh in 20 in 08E 0 to 5.0 inh in 5 psi 09E 0 to 10.0 inh in 5 psi 11E 0 to 20.0 inh in 5 psi 15E 0 to 1 psi in psi 15 psi 16E 0 to 2 psi in psi 15 psi 17E 0 to 3 psi in psi 15 psi 18E 0 to 5 psi in psi 15 psi 19E 0 to 15 psi in psi 30 psi 20E 0 to 30 psi in psi 60 psi **E Contact factory for other pressure ranges, displayed units and resolution Metric Units, Millimeters of Water Code (1) Range Displayed Resolution Maximum Units (2) Overpressure 01M 0 to 2.50 mmh mm 125 mm 02M 0 to mm 125 mm 04M 0 to mm 125 mm 05M 0 to mm 500 mm 06M 0 to mm 500 mm 08M 0 to mm 3.5 m 09M 0 to mm 3.5 m 11M 0 to mm 3.5 m 13M 0 to 1.00 m m 10 m 14M 0 to 2.50 m m 10 m 15M 0 to 5.00 m m 10 m 16M 0 to 10.0 m m 20 m 17M 0 to 20.0 m m 40 m **M Contact factory for other pressure ranges, displayed units and resolution Metric Units, Pascal Code (1) Range Displayed Resolution Maximum Units (2) Overpressure 01P 0 to 25 Pa Pa 1.25 kpa 02P 0 to 50 Pa Pa 1.25 kpa 04P 0 to 100 Pa Pa 1.25 kpa 05P 0 to 250 Pa Pa 5.0 kpa 06P 0 to 500 Pa Pa 5.0 kpa 08P 0 to 1.0 kpa Pa 35 kpa 09P 0 to 2.5 kpa Pa 35 kpa 11P 0 to 5.0 kpa Pa 35 kpa 13P 0 to 10 kpa Pa 100 kpa 14P 0 to 25 kpa Pa 100 kpa 15P 0 to 50 kpa Pa 100 kpa 16P 0 to 100 kpa Pa 200 kpa 17P 0 to 200 kpa Pa 400 kpa **P Contact factory for other pressure ranges, displayed units and resolution (1) Use this code when ordering. (2) This column shows the number of digits that are displayed and the position of the decimal point. Controller Relay J3, Connector Figure 3 Relay output Shows the internal wiring of the electromechanical relay. This type of output will switch small loads such as pilot lights or audible alarms. Also, the gold contacts offer a reliable output when a contact closure must be sensed and the current is very low. Transistor +5 VDC Controller Diode J3, Connector 1 (4) Terminals 2 (5) 3 (6) C NO NC 1 (4) Terminals 2 (5) 3 (6) Solid-state relay Figure 4 Transistor output, internal power supply A wiring diagram of the transistor output connected to a solid-state relay. The input voltage range of the relay is 3 to 32 VDC. Power is supplied by the internal 5 VDC supply of the controller. If an inductive load is connected, the internal diode will protect the transistor against transients.
6 Transistor Controller +5 VDC J3, Connector Diode* 1 (4) Terminals 2 (5) 3 (6) Load Power supply 40 VDC maximum *Diode required with inductive loads. Figure 5 Transistor output, external power supply Shows the transistor controlling a load powered by an external 12 or 24 VDC supply. An external diode or other means of limiting transients to 40 Volts must be added if the load is inductive. The current must not exceed 120 ma. Ordering Information Record selected option in blank indicated at bottom of form. DA Code Power Supply VAC VAC 3 24 VAC Code Input X See Standard Range Tables Code Offset 0 No offset A 1/4 offset B 1/2 offset Code Alarm Output R Electro mechanical T Transistor Code Energize (E) F Falling pressure R Rising pressure Code Option to 20 ma output DA Typical model number.
7
8 g B 2008 General Electric Company. All Rights Reserved. Specifications are subject to change without notice. GE is a registered trademark of General Electric Company. Other company or product names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affiliated with GE.
Analog Room Pressure Monitor RPC Series
Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the
More informationInstruction Manual Model A
706 Bostwick Avenue, Bridgeport, CT 06605 TEL: 203-368-6751 FAX: 203-368-3747 1-800-566-6822 www.devarinc.com Instruction Manual Model 18-232A LOOP POWERED ALARM MANUAL NO. 990029 MODEL 18-232A LOOP POWERED
More informationSoftware Version 2.01 LEVEL MONITOR MODEL 220
Software Version 2.01 LEVEL MONITOR MODEL 220 19 April 2000 CONTENTS 1. Introduction 1 1.1 Model Number Designation 2 1.2 Intrinsic Safety Considerations 3 2. Specification 4 3. Operation 6 3.1 Display
More informationBeck. The differential pressure transmitter for air
Beck. The differential pressure transmitter for air Differential pressure transmitter 984 General description The differential pressure transmitters of the 984 series are used to measure differential pressure,
More information86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated
SPECIFICATIONS 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature The 86 compensated is a small profile, media compatible, piezoresistive silicon pressure sensor packaged
More informationMODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power
Digital Panel Meters 47 Series THERMOCOUPLE INPUT DIGITAL PANEL METER (4-digit, LED display type) Functions & Features 4-digit thermocouple input digital panel meter 1/8 DIN size Moving average function
More informationMODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points
Digital Panel Meters 47 Series PULSE INPUT TOTALIZER (6-digit, LED display type) Functions & Features 6-digit digital panel meter 1/8 DIN size Process integration/totalization with scaling factor adjustment
More informationDNC-PS700-A10 Differential Pressure Control Meter. Operation and Installation Manual
DNC-PS700-A10 Differential Pressure Control Meter Operation and Installation Manual NationalControlsCorp. Phone 800-323-2593 Fax 630-231-1377 www.nationalcontrols.com MII-PS700-011 N ationalc o ntro ls
More information85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated
SPECIFICATIONS 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature The 85 compensated is a small profile, media compatible, piezoresistive silicon pressure sensor packaged
More informationTemperature Controllers
Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65
More informationSPM-4000-DC GUARDIAN INFINITY SPACE PRESSURIZATION MONITOR AND DUAL CONTROLLER
Technical Data Sheet SP-4000-DC GUARDIAN INFINITY PRESSURIZATION ONITOR AND DUAL CONTROLLER Description The Guardian Infinity is a true differential space pressure measurement system engineered to combine
More informationDWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series DH3 Digihelic Differential Pressure Controller.
Bulletin B-30 Series DH3 Digihelic Differential Pressure Controller Specifications - Installation and Operating Instructions DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Phone:
More informationOPERATION & MAINTENANCE MANUAL GUARDIAN SPACE PRESSURE MONITOR WITH REMOTE AUXILLARY ALARM
OPERATION & MAINTENANCE MANUAL GUARDIAN SPACE PRESSURE MONITOR WITH REMOTE AUXILLARY ALARM PARAGON CONTROLS INCORPORATED P.O. BOX 99 FORESTVILLE, CALIFORNIA 95436-0099 (707) 579-1424 /SPM REV. 7, 7/24/09
More informationDIGITAL METERS Large Display Temperature Meters Instruction Manual
DIGITAL METERS Large Display Temperature Meters PD755 PD756 PD757 Handles Thermocouple & RTD Inputs with Simplicity J, K, T, E, R, & S Thermocouples 100 Ω Platinum RTD (0.00385 or 0.00392 curve) Large
More informationPump-Up Controller MODEL 4062
Pump-Up Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4062 Pump-Up
More informationTable of Contents. Protective Relays
Table of Contents KILOVAC WD Series, DIN Rail or Screw Mounted Introduction..........................................................11-2 KILOVAC WD25 Paralleling Relays........................................11-3
More informationSeries DH3 Digihelic Differential Pressure Controller
Bulletin B-30 Series DH3 Digihelic Differential Pressure Controller Specifications - Installation and Operating Instructions DWYER INSTRUMENTS, INC. Phone: 219/879-8000 www.dwyer-inst.com P.O. BOX 373
More informationSierra Series 900 Single & Dual Channel System. Instruction Manual
Series 240/24 Instruction Manual Table of Contents Sierra Series 900 Single & Dual Channel System Instruction Manual Part Number IM-90-07/05 Revision D. 5 Harris Court, Building L Monterey, CA 93940 (83)
More informationConstruction Electrical
INDEECO offers a broad range of electrical components for temperature, safety, and power control. For most applications, the Control Option system, described in the previous section, makes it easy to specify
More informationUser's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm
User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance 5 List of
More informationMODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White
Digital Panel Meters 47 Series CT DIGITA PANE METER (4½ digit, ED display type, true RMS sensing) Functions & Features 4 ½ digit CT input digital panel meter 1/8 DIN size Moving average function to suppress
More information86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated
Compensated SPECIFICATIONS 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated The 86 compensated is a small profile, media compatible, piezoresistive silicon
More informationANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual
ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual From urgent alarms to routine messages, the PD141AFO VIGILANTE handles all types of operational messages with simplicity and economy. The VIGILANTE
More informationElectrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts
Standard Construction Control Options HEATREX offers a broad range of electrical components for temperature, safety, and power control. For most applications, the Control Option system, described in the
More informationNitrogen Dioxide (NO2) Single-Point Gas Detection System
Nitrogen Dioxide (NO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in nitrogen dioxide (NO)/diesel fume gas sensor, accepts one analog remote device such as a secondary
More informationModel A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES
Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION The Model A-5 low range wet/wet differential pressure transducer offers a stainless steel assembly. The Model A-5 line pressure zero shift
More informationSub psi SPECIFICATIONS
SPECIFICATIONS PC Board Mountable Pressure Sensor 40 mv Output Typical Differential Pressures Metal Tube and Ceramic Barbed Ports Temperature Compensated The 1210 sub PSI is a temperature compensated,
More informationPump-Down Controller MODEL 4052
Pump-Down Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4052 Pump-Down
More informationR Air flows from high pressure side to low pressure side. This principle can be applied to keep clean-air in the room or, alternatively, not to leak p
The first edition contrasted April 2011 Yamamoto Electric Works Co.,Ltd. T H E G E N E R A L C A T A L O G R We appreciate the importance of air. Manostar gage h t t p : / / w w w. m a n o s t a r. c o.
More informationCLEANROOM MONITOR CR3A Network - Installation Instructions
CLEANROOM MONITOR CR3A Network - Installation Instructions INTRODUCTION The CR3 Series Cleanroom Monitor, was developed specifically to allow for monitoring of confined spaces with accuracy and reliability.
More information154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.
SPECIFICATIONS Low Cost 316L Stainless Steel or Titanium 19mm Diameter Package 0-100mV Output Gage and Absolute Wide Compensated Temperature Range The 154BC is a 19mm small profile, media compatible, piezoresistive
More informationRPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features:
GE Oil & Gas RPS/DPS 8000 High Accuracy Resonant Pressure Sensor Since 1972, Druck has manufactured precision pressure sensors with a capability to meet critical applications in industrial, aerospace,
More informationAPM110 LOW AIR VELOCITY ALARM
home APM0 LOW AIR VELOCITY ALARM Ultra low velocity measurement Output as linear Velocity or Air volume Excellent repeatability Excellent Zero Stability Climate chamber compensated Long term span stability
More informationInstallation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode
Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER Low pressure with PI-control-mode Manufacturer: Phone: Fax: E-Mail: Website: Issue: Doc.-no.: Arthur Grillo GmbH Am Sandbach
More informationRPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:
GE Measurement & Control RPS/DPS 8100 High Accuracy Resonant Pressure Sensor For over 35 years, Druck has manufactured precision pressure sensors with a capability to meet critical applications in industrial,
More information86BSD Digital Output
SPECIFICATIONS Stainless steel with O-ring seal Pressure/temperature read-out Digital output ASIC calibrated Absolute, gage Cable/connector option Low power option 16mm diaphragm diameter The 86BSD is
More informationTable of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4
Table of Contents Page Quick Set-up Instructions 1 Theory of Operation 2 Specifications 3 TM 1003W Controls and Connections 4 1. Power Source Connector 5 2. Alarm Output Connector 5 3. Variation Detection
More information82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated
SPECIFICATIONS 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated The 82 constant voltage is a 19 mm small profile, media compatible, piezoresistive
More information86BSD Digital Output
SPECIFICATIONS Stainless steel with O-ring seal Pressure/temperature read-out Digital output ASIC calibrated Absolute, gage Cable/connector option Low power option 16mm diaphragm diameter The 86BSD is
More informationRamsey Motion Monitoring Systems
Ramsey Motion Monitoring Systems 60-200 Motion Monitoring Accurate Sensing of Underspeed, Overspeed and Zero Speed Conditions on Rotating Shafts and Machinery The Ramsey Series 60-200 Motion Monitoring
More information4 & 8-POINT ANNUNCIATORS Instruction Manual
4 & 8-POINT ANNUNCIATORS Instruction Manual 8 Field Selectable Sequences All Common ISA Sequences 4 or 8-Point (Channel) Monitoring Free Replaceable Message Labels Type 4X, NEMA 4X, IP65 Front Universal
More information/8 DIN Level Indicator
Data Sheet SS/_6 High visibility 5-digit LED display clear and accurate indication Analog and relay outputs as standard high, low, latch and rate alarms, plus isolated retransmission Maths functions included
More informationIS Series Pressure Sensing Switches
IS Series Pressure Sensing Switches FEATURES INSTALLATION INSTRUCTIONS IS3 PRESSURE SWITCH APPLICATION IS2 PRESSURE SWITCH The IS Series of pressure sensing switches offers the same proven compression
More information154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES
SPECIFICATIONS Low Cost 316L Stainless Steel or Titanium 19mm Diameter Package 0-100mV Output Gage and Absolute Wide Compensated Temperature Range FEATURES O-Ring Mount -20ºC to +85ºC Compensated Temperature
More informationUDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS
UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 4/01 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1000 and UDC1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers
More informationStandard SPECIFICATIONS FEATURES APPLICATIONS
SPECIFICATIONS PC Board Mountable Pressure Sensor 0-50 mv Output Voltage Excitation Gage, Absolute, and Differential Temperature Compensated FEATURES Dual-in-Line Package 0ºC to 50ºC Compensated Temperature
More informationCP CP
CP-8161-333 CP-8161-433 Electronic Programmable Controller Six Stage, Dual Setpoint General Instructions APPLICATION Electronic six stage programmable controller with proportional output for heating, cooling
More information86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated
Compensated SPECIFICATIONS 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated The 86 compensated is a small profile, media compatible, piezoresistive silicon
More informationData Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)
Data Sheet 220 LEVEL MONITOR Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com Model 220 Powered by 4-20mA loop Non-linear tank correction Four level alarms Level bar graph display
More informationNT DUAL CHANNEL DISPLAY. User Guide
NT DUAL CHANNEL DISPLAY User Guide Table of Contents Introduction... 2 Input Signals... 2 Output Signals... 2 User Programmable Features... 2 Installation... 3 Mechanical Installation... 3 Dimensional
More informationOxygen (O2) Single-Point Gas Detection System
Oxygen (O) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in oxygen (O) sensor, accepts one analog remote device such as a secondary gas sensor, temperature or humidity
More informationFree Chlorine Measuring System
Product Data Sheet PDS 71-FCL/rev.H September 2008 Model FCL Free Chlorine Measuring System COMPLETE SYSTEM INCLUDES sensor, connecting cable, analyzer, and flow controller. CONTINUOUS ph CORRECTION eliminates
More informationInductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.
Process Analysis Systems Chem Energy Pharm Food Water Stratos Eco 2405 CondI Inductive Conductivity Measurement Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement
More informationSystem 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules
System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage s FANs 930, 125 Product/Technical Bulletin S350 Issue Date 0300 The S350A, S351A, and S352A Stage s are intended to be used with System
More informationUSER S MANUAL INTERSYSTEM PRESSURE TRANDUCER TYPE PM-22
IO.PM-22.01(ENG) Edition 01.D.001/05.16 USER S MANUAL INTERSYSTEM PRESSURE TRANDUCER TYPE PM-22 APLISENS S.A., 03-192 Warszawa, ul. Morelowa 7 tel. +48 22 814 07 77; fax +48 22 814 07 78 www.aplisens.pl,
More informationNov 08 PRODUCT SPECIFICATION SHEET
Honeywell UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS 51-52-03-35 Nov 08 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1200 & UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN
More informationSpecifications - Installation and Operating Instructions
Bulletin B-31 Series DHII Digihelic II Differential Pressure Controller Specifications - Installation and Operating Instructions DWYER INSTRUMENTS, INC. Phone: 219/879-8000 www.dwyer-inst.com P.O. BOX
More informationDuct and Rough Service Carbon Monoxide Sensor
Product Identification and Overview Duct and Rough Service Carbon Monoxide Sensor BAPI s Carbon Monoxide Sensor offers enhanced electrochemical sensing with outstanding accuracy at low concentrations.
More informationMS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost
SPECIFICATIONS PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost The MS1471 is a piezoresistive silicon pressure sensor packaged in a surface mount configuration. It is intended
More informationTK-1801, TK-1811 TK-1801, TKR-1811
TK-1801, TK-1811 TK-1801, TKR-1811 Pneumatic Zero Energy Band Room Thermostats General Instructions APPLICATION For proportional control of pneumatically-operated sequenced heating and cooling valves and/or
More informationAutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.
AutomationDirect 1/16 DIN Series Technical Support We strive to make our manuals the best in the industry. We rely on your feedback to let us know if we are reaching our goal. If you cannot find the solution
More informationPressure Sensors: Measurement Type: Gage, Vacuum Gage; Signal Conditioning: Unamplified; Pressure Range: ± 15.0 psi; Port Style: Straight
Pressure Sensors: Measurement Type: Gage, Vacuum Gage; Signal Conditioning: Unamplified; Pressure Range: ± 15.0 psi; Port Style: Straight Features Representative photograph, actual product appearance may
More informationPD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual
PD154 & PD158 VIGILANTE II ANNUNCIATORS 8 Field Selectable Sequences All Common ISA Sequences 4 or 8-Point (Channel) Monitoring Free Replaceable Message Labels Type 4X, NEMA 4X, IP65 Front Universal Power
More informationModel 1062 Environment Monitor
Model 1062 Environment Monitor Continuously Monitors Environment Temperature Humidity Barometric Pressure Line Voltage Line Frequency Applications Manufacturing The 1062A Environment Monitor will ensure
More informationANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL
ANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL SAFETY WARNING Please Refer to the Safety Warning in Section 7.1 regarding the chemicals in the oxygen sensor Analox Sensor Technology
More informationUDC 700 Universal Digital Controllers and Indicator Specifications
UDC 700 Universal Digital Controllers and Indicator Specifications 51-52-03-28 August 2002 Overview The UDC 700 is a 1/32 DIN (49 x 25 mm) controller which combines a high degree of technology and quality
More informationModel OEM-2 INSTRUCTIONS FOR USE
ECO SENSORS, INC. 3-03.2 OEM OZONE CONTROLLER Model OEM-2 INSTRUCTIONS FOR USE GENERAL The model OEM-2 is a system to control ozone generators and alarms based on an adjustable ozone concentration set
More informationESSEX ENGINEERING CORPORATION
WATER/WASTEWATER TREATMENT CONTROL SYSTEMS AND SUBSYSTEMS 2000 SERIES CONTROL SYSTEMS: 2000 series are for surface mounting inside a control cabinet Model 2024 Electronic Alternator Duplex (two pump) pump
More informationVentostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.
GE Sensing & Inspection Technologies Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in
More informationVentostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.
GE Sensing & Inspection Technologies Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in
More informationSeries 5000 Hydrazine Analyzer Model 60002
Series 5000 Hydrazine Analyzer Model 60002 T he patented* Series 5000 Hydrazine Analyzer is a continuous-reading instrument using the p-dimethylaminobenzaldehyde method of analysis for colorimetric measurement
More information86BSD Digital Output
SPECIFICATIONS Stainless steel with O-ring seal Pressure/temperature read-out Digital output ASIC calibrated Absolute, gage Cable/connector option Low power option 16mm diaphragm diameter The 86BSD is
More informationDigital Meters 2002 SINCE 1974 CATALOG. Level Flow Temperature Pressure. PRECISION DIGITAL CORPORATION
Digital Meters 2002 SINCE 1974 2003 Level Flow Temperature Pressure CATALOG PRECISION DIGITAL CORPORATION The first section of our new 2002-2003 Catalog gives you a quick overview of the most important
More information85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage
FEATURES Weldable and Threaded Process Fittings -40ºC to +125ºC Operating Temperature ±0.1% Pressure Non Linearity Solid State Reliability APPLICATIONS Medical Instruments Process Control Fresh & Waste
More informationACL TC 200 TEMPERATURE CONTROLLER
TC 200 TEMPERATURE CONTROLLER TC 200 TEMPERATURE CONTROLLER WARNING This manual must be read in its entirety before installation of this controller. Installation must be performed by a qualified technician
More informationDP86 Constant Voltage with Fitting
SPECIFICATIONS 316L SS Wet/Wet Differential Low Pressure 0 100mV Output The DP86 constant voltage with fitting differential pressure sensor is a double-sided, media compatible, piezoresistive silicon pressure
More informationF PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.
F-2000 PC and AO OUTPUT BOARDS INSTRUCTION MANUAL Blue-White R Industries, Ltd. 500 Business Drive Huntington Beach, CA 92649 USA Phone: 714-89-8529 FAX: 714-894-9492 E mail: sales@blue-white.com or techsupport@blue-white.com
More informationECHOLINE LOW PRESSURE MONITOR. Prevents Unwanted Shutdown Time and Space Saving UL Recognized
ECHOLINE LOW PRESSURE MONITOR Prevents Unwanted Shutdown Time and Space Saving UL Recognized P R E C I S I O N S E N S O R S ECHOLINE overview ECHOLINE was designed in cooperation with a leading semiconductor
More informationPioneer-R16 Gas Monitor Operator s Manual
Pioneer-R16 Gas Monitor Operator s Manual Edition 7/2/97 RKI INSTRUMENTS, INC RKI Instruments, Inc. 33248 Central Ave, Union City, CA 94587 (510) 441-5656 Chapter 1: Description About the Pioneer-R16 Gas
More informationInstallation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified
Installation Instructions for the MicroPressure Board Mount Pressure Sensors Compact, High Accuracy, Compensated/Amplified Issue C 32333868 General Information The is a very small piezoresistive silicon
More informationOperating Instructions tico Temperature Indicator
Operating Instructions tico 735 - Temperature Indicator Introduction Your Hengstler tico 735 Temperature Indicator is one model in a family of 1/8 DIN units which offers breakthrough display technology
More informationI/A Series 716C 1/16 DIN Temperature Controller
Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of
More informationThermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery
Thermo Scientific Ramsey TM Series 60-200 Sensing Speed Conditions on Rotating Shafts and Machinery The Thermo Scientific Ramsey Series 60-200 monitors under-speed, overspeed and zero-speed conditions
More informationvibration switch
user manual 440-450 vibration switch INSTALLATION - OPERATION - MAINTENANCE Z0592822_A ISSUED 06/2017 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. contents Section 1 -
More informationDruck DPI 705/DPI 705 IS Series
GE Sensing & Inspection Technologies 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Druck DPI 705/DPI 705 IS Series Digital Pressure
More informationIntelliPack : 800 Series
800 Series Models by Function Guide 800T Intelligent Transmitters 800A Intelligent Alarms 890M Math/Computation IntelliPack transmitter units convert sensor inputs to isolated process current or voltage
More informationDE20 INSTRUCTION MANUAL
DE20 INSTRUCTION MANUAL Now UL Listed! SET POINT DE20 SET YOUR DISTRIBUTOR: Chemical Distributors, Inc. 80 Metcalfe Street - Buffalo, NY 14206 Phone: 800-777-2436 716-856-2300 Fax: 716-856-7115 sales@cdibuffalo.com
More informationAccuracy by Design Products for the HVAC Professional
Accuracy by Design Products for the HVAC Professional Greystone Energy Systems Inc., is one of North America s largest ISO registered manufacturers of HVAC sensors and transducers for Building Automation
More informationProcess & TeMPerATUre UniversAl input DigiTAl MeTers
Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min
More informationSeries A3 and A4 Differential Pressure Controller
Bulletin 102-0 Installation and Operation Series A3 and A4 Differential Pressure Controller Sensocon, Inc. Phone: (863) 248-2800 Fax: (863) 248-2798 www.sensocon.com 1. Introduction 1.1. Model Number Configuration
More informationInteractive Catalog Replaces Catalog Pages
Interactive Replaces Pages Honeywell Sensing and Control has replaced the PDF product catalog with the new Interactive. The Interactive is a power search tool that makes it easier to find product information.
More informationCONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.
CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse
More informationTwo-Channel Gas Controller
Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously
More information02/11/2015
CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint
More informationINSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.
INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3 M336 Rev F November 21, 2000 ÇConsilium Consilium US, Inc. 59 Porter Rd Littleton, MA 01460-1431 USA
More informationZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement
Data sheet High Temperature Zirconia Oxygen Analyzer Superior technology and quality from the world leader in oxygen measurement User-friendly language options selectable system analysis comprehensive
More informationCarbon Monoxide Transmitter
Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or
More informationProduct Manual SZ1144
Product Manual SZ1144 Refrigeration Temperature Monitor Communicating Controls Description The SZ1144 is a microprocessor-based monitoring and alarm interface designed to monitor up to four 1000 Ω platinum
More informationMobrey MCU900 Series Universal Control Unit
Universal Control Unit Intrinsically Safe power supply to transmitter 4 20mA HART input Isolated 4 20mA output Five control relays Multi-function back lit display Wall or panel mount Pre-programmed linearization:
More informationExercise 1. Introduction to Sensors EXERCISE OBJECTIVE
Exercise 1 Introduction to Sensors EXERCISE OBJECTIVE When you have completed this exercise, you will be introduced to photoelectric, capacitive and inductive sensors; You will also be introduced to the