Test Report for Senko Advanced Components, Report No RES3005 February 22, Test Report. Senko Advanced Components
|
|
- Daniela Alexander
- 5 years ago
- Views:
Transcription
1 Test Report Report No. Client: Address: RES3005 Senko Advanced Components 225 Cedar Hill Street Marlboro, MA Phone: Product Tested: Q-XP MSOC 900m Test Dates: April 2010 October 2010 Prepared By: Sean Grenon Lab Manager Issue Date: February 22, Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
2 Samples Tested: Q-XP SC/APC 900micron Mechanical Splice on Connector Summary Testing was performed in accordance with Telcordia standard GR-1081-CORE Generic Requirements for Field Mountable Optical Fiber Connectors Issue 1 January The samples represented in this report were tested at Resolute Technologies under a third party witness program by Underwriters Laboratories. The full results from this testing program are represented in UL report number 10CA14846 rev 2, this report is meant to be a summary of those test results. Contents: Test Section # Page Test Section # Page New Product Measurements Impact Test Wavelength Dependency Durability Thermal Age End of test Criteria Thermal Cycle Extended Thermal Age Humidity Age Extended Humidity Age Humidity Condensation Cycle Extended Thermal Cycle Post Condensation Thermal Cycle Airborne Contaminants Vibration Salt Spray Twist Test Immersion Corrosion Transmission with Applied Load Ground Water Immersion Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
3 New Product Measurements: 3 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
4 4 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
5 5 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
6 6 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
7 New Product Geometry Radius of Curvature: Fiber Height: 7 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
8 Apex Offset: Test Report for Senko Advanced Components, Report No RES3005 February 22, 2011 GR-1081section 4.2 -Wavelength Dependency Testing 8 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
9 GR-1081 Section Thermal Age, 85ºc uncontrolled Humidity 168 hours 9 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
10 GR-1081 Section Thermal Cycle, 75ºc to -40ºc uncontrolled Humidity 168 hours 10 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
11 GR-1081 Section Humidity Age, 75ºc with 95% RH 168 hours 11 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
12 GR-1081 Section Humidity Condensation Cycle, -10ºc to 65ºc 168 hours 12 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
13 GR-1081 Section Post Condensation Thermal Cycle, 75ºc to -40ºc 168 hours 13 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
14 GR-1081 Section Vibration Summary, Final Reading Z-Axis 14 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
15 15 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
16 GR-1081 Section Twist Test 16 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
17 17 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
18 GR-1081 Section Transmission with Applied Load Test Summary Note: Summary shows non compliances with R30 fiber type. Fiber types R15, R7.5 and R5 were compliant. 18 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
19 GR-1081 Section Impact Test 19 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
20 20 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
21 GR-1081 Section Durability 21 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
22 End of Test Criteria: IL, RL and Geometry 22 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
23 23 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
24 Ext Thermal Age (GR ) - 85ºc Uncontrolled Humidity, Duration: 2000 Hrs. 0.6 Extended Thermal Age 2000 Hr. 0.5 Insertion loss db G657.B3 G.657B G.657A G.652D Sample # 0.6 Extended Thermal Age 2000 Hr. 1550nm Insertion Loss db G657.B3 G.657B G.657A G.652D 6E Sample# 24 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
25 -80 Extended Thermal Age 2000 hr. Return Loss db G657.B3 G.657B G.657A G.652D Sample# -80 Extended Thermal Age 2000 Hr. 1550nm Return Loss db G657.B3 G.657B G.657A G.652D Sample# 25 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
26 Ext Humidity Age (GR ) - 75ºc with 95% RH, Duration: 2000 Hrs. 0.6 Extended Humidity Age 2000 Hr. 1310nm Insertion loss db G657.B3 G.657B G.657A G.652D 6E Sample# 0.6 Extended Humidity Age 2000 Hr. 1550nm Insertion Loss db G657.B3 G.657B G.657A G.652D 6E Sample# 26 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
27 -80 Extended Humidity Age 2000 Hr. 1310nm Return Loss db G657.B3 G.657B G.657A G.652D Sample# -80 Extended Humidity Age 2000 Hr. 1550nm Return Loss db G657.B3 G.657B G.657A G.652D Sample# 27 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
28 Ext Thermal Cycle (GR ) - 75ºc to -40ºc Uncontrolled Humidity, Duration: 2000 Hrs. 0.6 Extended Thermal Cycle 2000 Hr. 1310nm Insertion Loss db G657.B3 G.657B G.657A G.652D 6E Sample# 0.6 Extended Thermal Cycle 2000 Hr. 1550nm Insertion Loss db G657.B3 G.657B G.657A G.652D 6E Sample# 28 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
29 -80 Extended Thermal Cycle 2000 Hr. 1310nm Return Loss db G657.B3 G.657B G.657A G.652D Sample# -80 Extended Thermal Cycle 2000 Hr. 1550nm Return Loss db G657.B3 G.657B G.657A G.652D Sample# 29 Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
30 Airborne Contaminants Test GR-326 section Salt Spray Test GR-326 section Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
31 Immersion/Corrosion Test GR-326 section Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
32 Groundwater Immersion Test GR-326 section Resolute Technologies- 168 Ayer Road Littleton, MA Phone: Fax:
GR-326-CORE Singlemode Optical Connectors and Jumper Assemblies
Preface...Preface 1 1. Introduction... 1 1 1.1 Purpose and Scope... 1 1 1.2 Target Audience... 1 2 1.3 Structure and Use of This Document...1 2 1.4 Changes from Issue 2 of GR-326-CORE... 1 3 1.5 Requirements
More informationQualification Test Report LC Duplex Adapter For LC Cutouts
Qualification Test Report LC Duplex Adapter For LC Cutouts 501-683 09Mar09 Rev B 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics LC Duplex Adapters for LC Cutouts, to determine their
More informationAttenuators. Fiber Optic Products Catalog. Singlemode Build Out Attenuators. Product Facts. Applications. Customizable Features. Available Collateral
Attenuators Build Out Attenuators Product Facts A range of fixed attenuation values. Standard values of 1 through 20 and 25dB UPC and APC offer Excellent Return Loss LC, SC, FC, ST, and D4 styles Attenuation
More informationProduct Specification Qualification Test Report
PS 88 / DMI PC SM / 6/5 DIAMOND Test & Calibration Laboratory STS 333 / SCS 11 Product Specification Qualification Test Report DMI PC SM DIAMOND SA Via dei Patrizi 5 CH-6616 LOSONE Tel. +41 91 785 45 45
More informationJan07 Rev B
Qualification Test Report 501-545 05Jan07 Rev B MT-RJ Patch Panel and Outlet Jacks (Standard, XG, SECURE and SECURE XG) 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics MT-RJ Jack,
More informationEnsuring Cabling Performance in the Customer-Owned Outside Plant
Ensuring Cabling Performance in the Customer-Owned Outside Plant Needs to be able to qualify the installation to validate bandwidth requirements are met Future high bandwidth applications Future Proof
More informationEnsuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications
Ensuring Cabling Performance in the Customer-Owned Outside Plant Keith Foord Product Manager Greenlee Communications Introduction: Outside plant fiber networks require low reflectance terminations for
More informationINTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
INTERNATIONAL TELECOMMUNICATION UNION ITU-T L.36 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (10/98) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
More informationApr06 Rev A
Qualification Test Report LC, Multimode, One-Piece Housing, Fiber Optic Connector 501-628 03Apr06 Rev A 1. INTRODUCTION 1.1. Purpose 1.2. Scope Testing was performed on Tyco Electronics LC multimode, one-piece
More informationQualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)
Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable) 501-586 26Feb09 Rev F 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics LightCrimp*
More information/Mar/2014 Rev A
Qualification Test Report 501-93038 21/Mar/2014 Rev A MPOptimate FO Microcassette 12 fiber MPO-12xLC/PC 1. INTRODUCTION 1.1 Purpose Tests performed on MPOptimate FO Microcassette 12 fiber MPO-12xLC/PC,
More informationBest Practice Briefing
Best Practice Briefing Fiber Optic Connector Handling, Inspection, andcleaning microwave photonic systems Expand Your RF Horizons Briefing Overview Personnel Safety & Best Practices Insertion Loss (IL)
More informationFibre Specification Standards
Fibre Specification Standards User Manual The most important thing we build is trust Cobham Wireless - Coverage Table of Contents 1. Single-mode Fibre to ITU-T Recommendation G.652 3 2. SC/APC Mated Pair
More informationJul07 Rev C
Product Specification 108-2167 11Jul07 Rev C MPO and MPO SECURE Multimode Fiber Optic Connector and Adapter 1. SCOPE 1.1. Content This specification, which is based on GR-1435-CORE, covers the performance,
More informationSumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003
Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber PureGuide SM Optical Fiber, TIA Type IVd Issued: November 2003 78 Alexander Drive, Research Triangle Park, NC 27709 Phone
More informationSumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber
Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber PureGuide -LA SM Optical Fiber, TIA Type IVd ITU G.655 C and D Compliant Issued:
More informationETSI TS V1.2.1 ( )
TS 100 783 V1.2.1 (2004-08) Technical Specification Transmission and Multiplexing (TM); Passive optical components; Fibre optic fusion splices for single-mode optical fibre transmission systems for indoor
More informationTECHNICAL REPORT Crimp Splice Protection -250M/P150 mark 2
FIBER OPTIC TECHNOLOGY CALIBRATION LABORATORY Document number: TZ_2_7_PP_EN_splice TECHNICAL REPORT Crimp Splice Protection -25M/P15 mark 2 E.G. Tec Ltd. Date: May-1-27 TZ_2_7_EN_splice Contents: 1. General...
More informationLaserPlus Model LP-OA EDFA OPERATING MANUAL
LaserPlus Model LP-OA EDFA OPERATING MANUAL 24926 Highway 108 Sierra Village, CA 95346 Phone: (800) 545-1022 Fax: (209 586-1022 025-370571 Rev. X1 E-Mail: sales@olsontech.com 04/13/11 TABLE OF CONTENTS
More informationProduct Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)
Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming) 02Oct08 Rev A 1. SCOPE 1.1. Content This specification, based on IEC 61753-1 Edition 1.0 tests for Category E (Extreme Environment),
More informationQualification Test Report. AMP-TWIST Series Jacks for Class EA systems
Qualification Test Report 501-93032 14/April/2011 Rev A AMP-TWIST Series Jacks for Class EA systems 1. INTRODUCTION 1.1 Purpose Qualification testing on AMP-TWIST* Series Jacks for Class E A Systems, to
More information4120 Fire Alarm Network Reference
4120 Fire Alarm Network Reference Features Autocall 4120 Fire Alarm Network communications are available for wired or fiber optic connections Wired communications are available on Network Interface Cards
More information2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK
PART 1 GENERAL 1.01 SCOPE OF WORK SECTION 27 12 23 FIBER OPTIC DATA NETWORK A. Furnish, install, terminate, and test all fiber optic equipment and cabling necessary for a complete and functional data highway
More informationDome Fiber Optic Closure SC-221
Dome Fiber Optic Closure SC-221 General Information SC-221 fiber optic closure protects the fiber optic splices from harsh external environment conditions. It is designed for many network segments and
More informationDraft ES V1.1.1 ( )
Standard Transmission and Multiplexing (TM); Passive optical components; Fibre optic mechanical splices for single-mode optical fibre communications systems; Common requirements and conformance testing
More informationITU-T L.404. Field mountable single-mode optical fibre connectors
I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n ITU-T L.404 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (08/2017) SERIES L: ENVIRONMENT AND ICTS, CLIMATE CHANGE, E-WASTE, ENERGY
More informationFibre Optic Basics FIA Summer Seminar 2014
Fibre Optic Basics FIA Summer Seminar 2014 Andrew Cole Theory Basics Characteristics of Light What is Light? An electromagnetic wave, which like other waves, has a frequency (f), velocity (v) and a wavelength
More informationFTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)
TE Connectivity's (TE) FTTX infrastructure solutions are designed from the ground up to meet the unique requirements of FTTX networks. Designed for operational efficiency and scalability, TE s FTTX solutions
More informationUC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011
UC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011 GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) UC INSTRUMENTS GM8036
More informationConnections You Can Count On.
Connections You Can Count On. XPRESS ULTRA FIBER CONNECTOR PRODUCT GUIDE - CLEANING & INSPECTION - TESTING AND TROUBLE SHOOTING - XPRESS ULTRA FIBER CONNECTORS - INSTALLATION KITS Connections You Can Count
More informationPRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector
PRODUCT SPECIFICATION 108-115057 29OCT13 Rev. A1 0.5mm Fine Stacking Hermaphroditic Type BTB Connector 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for 0.5mm
More informationFiber Optic Patch Cord and Pigtails
Fiber Optic Patch Cord and Pigtails Description The optical fiber patch cords are fitted at both ends with same connector types or different connector types. Our fiber optic patch cords are ultra reliable
More informationOptical Fiber Monitor (OFM) Whitebox WB-OFM-1262-DC
Optical Fiber Monitor (OFM) Whitebox WB-OFM-1262-DC www.lumentum.com Data Sheet The Lumentum Optical Fiber Monitor (OFM) Whiteboxes reduce network downtime with automated fault location. Detecting and
More informationOptical Time Domain Reflectometry (OTDR)
Experimental Optics Contact: Helena Kämmer (helena.kaemmer@uni-jena.de) Last edition: Helena Kämmer, January 2017 Optical Time Domain Reflectometry (OTDR) Contents 1 Overview 3 2 Safety issues 3 3 Theoretical
More informationETSI TS V1.2.1 ( )
TS 101 263 V1.2.1 (2004-07) Technical Specification Transmission and Multiplexing (TM); Passive optical components; Fibre optic mechanical splices for single-mode optical fibre communications systems for
More informationACCESS Master MT9085 Series. Product Introduction
ACCESS Master MT9085 Series Product Introduction Strengthen of MT9085 Series: 1/5 All Optical Fiber Evaluation Functions in One Tester The ACCESS Master MT9085 series is an all-inone tester with OTDR,
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationJUL 18 Rev A1
Qualification Test Report 501-166004 30 JUL 18 Rev A1 Mini USB-B Header, H-Type SMT 1. INTRODUCTION 1.1. Purpose Testing was performed on the Mini USB-B Header, H-Type SMT to determine if it meets the
More informationFibrlok II 2529 Universal Optical Fiber Splice
Fibrlok II 2529 Universal Optical Fiber Splice Technical Report December 1994 Issue 1, 78-8098-3415-9 1 1.0 Product Description The 3M brand Fibrlok II 2529 Universal Optical Fiber Splice is a high performance,
More informationOWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015
Laser OWL Series Operations Guide Singlemode Light Sources OWL Optical Wavelength Laboratories Operations Guide Laser OWL and Laser OWL HP Singlemode Light Sources Date: October 1, 015 Version.5 Optical
More informationOptical Multitester 500 450 OTDR EMEA & APac Edition Issue 1 Page 1 of 10 Description The 450 OTDR is a PC based state-ofthe-art OTDR designed for field applications. It is a dedicated OTDR which offers
More informationErbium-Doped Fiber Amplifier (EDFA) - MW Series
Nanovation s MW series of EDFA products is designed for applications in advanced dense wave division multiplexing (DWDM) systems where high performance and reliability are critical. They are available
More informationMADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments
MADE FOR THE TRADE! professional FIBER OPTIC XL fibertools Series instruments XL fibertools Series Instruments Designed for Fiber Optic Cable Testing. The XL fibertools are designed for the professional
More informationOTDR II. Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling
Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling The OTDR II is the first tablet
More informationCM97-xxx-7x. Cooled 980nm Pump Laser Module. Product Datasheet. Features. Applications
Cooled 980nm Pump Laser Module Features High output power, >1.0W kink free Fiber Bragg grating stabilization for wavelength locking over the entire operating conditions Hermetically sealed 10pin mini-butterfly
More informationVTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links
VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links TB Number 004 This bulletin is supplied for information only and is intended to provide
More informationMADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments
MADE FOR THE TRADE! FIBER OPTIC professional XL fibertools Series instruments XL fibertools Series Instruments Designed for Fiber Optic Cable Testing. The XL fibertools are designed for the professional
More informationCooled Butterfly 980nm Pump Laser Module
Cooled Butterfly 980nm Pump Laser Module Features: High output power, up to 600mW kink free Polarization maintaining fiber pigtail Fiber Bragg grating stabilization for wavelength locking over the entire
More informationFibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC. Philip C Longhurst Corporate Fibre Optic R & D Manager
Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC Philip C Longhurst Corporate Fibre Optic R & D Manager Outline CENELEC TC86BXA work programme IEC SC86B WG 6 and
More informationAPR 17 Rev A
Product Specification 108-130015 11 APR 17 Rev A ChipConnect Cable Assembly 1. SCOPE 1.1. Content This specification covers performance, test and quality requirements for the ChipConnect Cable Assembly
More informationLink loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team
Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team INTRODUCTION The OTDR is a very efficient tool for characterizing the elements on
More informationPUMP AND SIGNAL COMBINERS
Pump and Signal Combiners For Fiber Laser and Amplifier Design A Furukawa Company www.ofsoptics.com PUMP AND SIGNAL COMBINERS for Fiber Laser and Amplifier Design Multimode Single-mode Polarization-Maintaining
More informationGLOBAL ENCLOSURE STANDARDS WITHIN THE ELECTRICAL INDUSTRY
GLOBAL ENCLOSURE STANDARDS WITHIN THE ELECTRICAL INDUSTRY Industry standards for electrical enclosures exist to promote safety, encourage design efficiency and define minimum levels of product performance.
More informationAnimals:Goats:Bleat.Calls,Warbling.Baa,Movements.Rubbing,Barn,Medium.Close,Interior,BG.Dog.Barks 01:21.618
Description Duration Animals:Goats:Bleat.Calls,Warbling.Baa,Movements.Rubbing,Barn,Medium.Close,Interior,BG.Dog.Barks 01:21.618 Animals:Goats:Herd,Bleat.Calls,Intensity.Increase,Warbling,Baby.Baa,Movements.Rubbing,Barn,Occasional.Dog.Barks,Medium.Close,Interior,BG.Crows.Squawks
More informationFire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.
UL, ULC Approved* Fire Control Panels Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting Features Converts multiple fire alarm communications signals into a single fiber optic
More informationCopper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.
Product Specification 108-93018 25/Aug/2011 Rev H Copper LAN cable 1. SCOPE 1.1. Content This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. 2. APPLICABLE DOCUMENTS
More informationFiber Optic Distribution Cables (6-144 Fibers)
900um Buffered Aramid Yarn Strength Members Outer 6 or 12 Subunit Central Strength Member Outer Ripcord Single Unit Cable 6-24 Multi-Unit Cable 24-144 Description: AMP NETCONNECT distribution cables are
More informationFree Height 0.8 mm Pitch Board-to-Board Connector (SMT)
Product 108-5390 Specification 31 OCT 17 Rev.F1 Free Height 0.8 mm Pitch Board-to-Board Connector (SMT) 1. SCOPE 1.1. Contents This specification covers the requirements for product performance, test methods
More informationProduct Information. Optical fibre water sensor. - Early warning system for ensuring maximum availability of optical transmission routes
C:\Users\Public\Dieter Dokumente\Wolf\Wolf Info\Sensor\Englisch\[WO]-E Water Sensor (Product Product Information Optical fibre water sensor - Early warning system for ensuring maximum availability of optical
More informationSECTION TESTING OF FIBER OPTIC CABLES
SECTION 27 08 23 TESTING OF FIBER OPTIC CABLES PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction,
More informationIntegrated optical fiber shape senor modules based on twisted multicore fiber grating arrays
Integrated optical fiber shape senor modules based on twisted multicore fiber grating arrays P. S. Westbrook, K.S. Feder, T. Kremp, T. F. Taunay, E. Monberg, J. Kelliher*, R. Ortiz, K. Bradley +, K. S.
More informationEOTec 2C32 Installation Guide
ControlNet Dual Ring Modules For the EOTec 2000 Series November 2008 Weed Instrument Company, Inc. 707 Jeffrey Way, P.O. Box 300 Round Rock, TX 78680-0300 USA Tel: 512-434-2850 Fax: 512-434-2851 E-mail:
More information2 Specialty Application Photoelectric Sensors
SMARTEYE HIGH INTENSITY 2 Specialty Application Photoelectric Sensors High Intensity Through Beam Sensor www.ttco.com 800-237-0946 2-121 Specialty Application Photoelectric Sensors 2 SMARTEYE HIGH INTENSITY
More informationECP OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS
Network(s): Summary: ENGINEERING COMMISSIONING PROCEDURE ECP 11-0009 OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS EPN, LPN, SPN This standard details the requirements for the splicing,
More informationMar11 Rev B
Product Specification 108-1576-2 11Mar11 Rev B NETCONNECT*, CHAMP* System 5 Modular Jack Patch Panel 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for NETCONNECT*
More informationMX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA
MX1A and MX1B: Laser Displacement Detection MX1A and MX1B: Laser Displacement Detection Built-in math capabilities available (MX1B only) Digital display on amplifier; easy setting and monitoring (MX1B
More informationFLX380-30x FlexTester OTDR
Features 3rd generation hand-held, all-in-one OTDR, Source, Power Meter, VFL Icon-based LinkMap display with pass/fail for easy network analysis Patented in- or out-of-service testing from a single port
More informationAdvancing Fiber Optic Connectivity
Advancing Fiber Optic Connectivity Fusion Spice-On Connectors by Brad Everette, America Ilsintech, Dallas, TX and Seung-Min Lee, Ilsintech, Daejeon, South Korea Presentation Overview Advancements in Fiber
More informationExtreme High-Intensity Sensors Thru-Beam and Fiberoptic Penetrates Many Packaging Materials for Content Verification
SPECIALTY APPLICATION PHOTOELECTRIC SENSORS Extreme High-Intensity Sensors Thru-Beam and Fiberoptic Penetrates Many Packaging Materials for Content Verification -104 High-Intensity Sensors The Model HSLS-1
More information9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series
COMMERCIAL LASERS 9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series Key Features Diffraction-limited light delivered through fiber termination module Single transverse mode, collimated beam
More informationCore Alignment All In One Fusion Splicer
Economical Solution for Integrated Fiber Preparation Tool Demand. Core Alignment All In One Fusion Splicer Single Optical Fiber Fusion Splicer US Patent /9 2,09 The Revolution of a Splicer Integrated to
More informationDWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series
MTP-200-D100 Hand-held High Performance OTDR DWDM OTDR with Tunable Laser Series Multi-Function and High Performance OTDR Testing 96 C-band wavelengths Dynamic range up to 38dB Short zone: EDZ 1m, ADZ
More informationDatasheet Palm OTDR. Product Summaries
Datasheet Palm OTDR AV6416 palm OTDR is the newest instrument designed for testing FTTx network. It s mainly used to measure the physical characteristics of optical fiber under test, such as the length,
More informationEOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings
EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings Key Features Single and Dual Channel Self Healing Rings for High Reliability
More informationTABLE OF CONTENTS. 1.0 INTRODUCTION Scope References Test Specimen Description Summary 1
Page No. TOC-i TABLE OF CONTENTS Page No. 1.0 INTRODUCTION 1 1.1 Scope 1 1.2 References 1 1.3 Test Specimen Description 1 1.4 Summary 1 2.0 TEST PROCEDURES AND RESULTS 2 2.1 High Temperature Test 2 2.2
More informationAccelerating NBN fiber testing. Tom Ronan Marketing Lead Fiber Optics Melbourne
Accelerating NBN fiber testing and workforce Performance. Tom Ronan Marketing Lead Fiber Optics Melbourne Agenda Network Elements and Parameters Distributed Fiber Network (DFN) Construction Network Activation
More informationApplications Engineering Notes
Applications Engineering Notes Document Title Document Number Revision Number Product Specification and Qualification Test Report: IBC Brand Fiber Optic Connector Cleaner MT38 II AEN-1146 Issue Effective
More informationUpdate and Overview on the NFPA Requirements and Testing for Electronic Safety Equipment
Update and Overview on the NFPA Requirements and Testing for Electronic Safety Equipment Bruce H. Varner. Chair NFPA Technical Committee on Electronic Safety Equipment Fire Chief (Retired) Santa Rosa,
More informationMINI2. Inno Mini 2 Specs Provided by MOST ACCURATE COMPACT OTDR
Inno Mini 2 Specs Provided by www.aaatesters.com MOST ACCURATE COMPACT OTDR SOLA (Smart Optical Link Analyzer) 5 Touch Screen with Smart GUI 8GB Internal Storage with Internal SD Card & External USB Memory
More informationRemote fiber testing to improve SLA s
Remote fiber testing to improve SLA s Presented by : Kamel SOUILAH System Sales Engineer kamel.souilah@exfo.com 2010 EXFO Inc. All rights reserved.. 1 EXFO is the leader in the test and measurement solutions
More informationOZ Optics Limited. Fiber Optic Attenuators. June 2018
OZ Optics Limited Fiber Optic Attenuators June 2018 1 Company Profile Company founded in 1985 Corporate headquarters located in Ottawa, Canada Manufacturing facility in Ottawa/Canada, Izmir/Turkey, and
More informationOn-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000
brochure On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000 Advanced Sensors Ltd Oil in Water Analyser System known as the OIW-EX100 or OIW-EX 1000. The system is designed to monitor
More informationA Cost Effective Multi-Spectral Scanner for Natural Gas Detection
A Cost Effective Multi-Spectral Scanner for Natural Gas Detection Semi-Annual Progress Report No. 1 Reporting Period Start Date: October 1, 2003 Reporting Period End Date: March 31, 2004 Principal Authors:
More informationTechnical Specification for the Mastic-Sealed Fiber-Optic Closure System (FOSC 300C)
Page 1 of 24 Prepared by: Chris Radelet R&D Department Manager Approved by: Pieter De Coster Product Manager for the Mastic-Sealed Fiber-Optic Closure System (FOSC 300C) The FOSC 300C closure system is
More informationNFPA Electronic Safety Equipment Standards What s happening now!
Precision Indoor Personnel Location and Tracking for Emergency Responders Technology Workshop August 4-5, 2008 Worcester Polytechnic Institute, Worcester, MA NFPA Electronic Safety Equipment Standards
More informationAV6416 OTDR. Product Overview: Main Features:
AV6416 OTDR Product Overview: AV6416 OTDR is a test instrument designed for FTTx. It s mainly used to measure the physical characteristics of optical fiber & cables, including length, transmission loss
More informationCHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES
THE CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES 17th September 2002 Botanical Gardens Birmingham The Way We Were 1GbE and 10GbE OF Categories Channel Design Cleaning SFF Connecting Hardware Testing
More informationThe Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise
The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise 1 The purpose of the exercise...2 2 Background...2 2.1 Introduction to scattering and attenuation...2 2.2 Introduction to
More informationTechnical Data Sheet 5mm Infrared LED, T-1
Technical Data Sheet 5mm Infrared LED, T-1 Features High reliability 2.54mm lead spacing Low forward voltage Good spectral matching to Si photodetector Pb free The product itself will remain within RoHS
More informationLuna Technologies Webinar Series. New Rayleigh-Based Technique for Very High Resolution Distributed Temperature and Strain Sensing
Luna Technologies Webinar Series New Rayleigh-Based Technique for Very High Resolution Distributed Temperature and Strain Sensing Dr. Dawn Gifford Senior Optical Engineer Mr. Ed Valigursky VP of Sales
More informationThe True Value of Connector Inspection: New Challenges and Best Practices
The True Value of Connector Inspection: New Challenges and Best Practices Vincent Racine Product Line Manager August 2011 1 Table of contents 1 Best Practices 2 Connector Inspection Tools 3 Connector Inspection
More informationReinforced FBG Sensors Serve Demanding Applications
Reinforced FBG Sensors Serve Demanding Applications Kevin Hsu, Andrei Csipkes, and Tommy Jin Technica Optical Components / 3657 Peachtree Rd, Suite 10A, Atlanta, 30319, USA, info@technicasa.com, www.technicasa.com
More informationSpecification MBT801-S
Specification MBT801-S Drawn SSC Approval 고객명 Approval www. MBT801-S 1. Features 2. Absolute Maximum Ratings 3. Electro Characteristics 4. Optical characteristics 5. Outline Dimension 6. Packing 7. Soldering
More informationAQ7275 OTDR Optical Time Domain Reflectometer
AQ7275 OTDR Optical Time Domain Reflectometer Wide range of models available Supporting FTTH to core networks Short dead zone (0.8 m) High dynamic range (45 db) Dead zone Bulletin AQ7275-02E Meets a broad
More informationSENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -
The sensor is designed for frequent washdowns with a corrosion-resistant AISI316L stainless steel case IP69K rated, compliant to test environments like indicated by Diversey and Ecolab. However, all models
More informationMINI2 MOST ACCURATE COMPACT OTDR
MOST ACCURATE COMPACT OTDR SOLA, Simplify The OTDR Test Process 5 Touch Screen with Smart GUI 8GB Internal Storage with Internal SD Card & External USB Memory Built-In VFL and Light Source Fast Booting
More informationFiber Guardian. Fiber Guardian. Where fiber monitoring starts. Key Features
STAND-ALONE REMOTE OTDR UNIT Fiber Guardian NETWORK TESTING ACCESS Fiber Guardian Where fiber monitoring starts. Key Features All-in-one remote OTDR testing and monitoring functions Multitasking test system
More informationPONA Rack Mounted Erbium Doped Fiber Amplifier. User s Manual r001 August 30, W. Chestnut St Alhambra, CA 91803
PONA 2114-2127 Rack Mounted Erbium Doped Fiber Amplifier User s Manual 21061785r001 August 30, 2005 EMCORE CORPORATION 2015 W. Chestnut St Alhambra, CA 91803 Tel: (626) 430-4000 Fax: (505) 430-4060 www.emcore.com
More informationVIEW500 USER-FRIENDLY STANDARD OTDR
USER-FRIENDLY STANDARD OTDR SOLA (Smart Optical Link Analyzer) 7 Touch Screen with Smart GUI 8GB Internal Storage with Internal SD Card & External USB Memory Built-In VFL, Light Source and OPM Fast Booting
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 NATIONAL TECHNICAL SYSTEMS (NTS) 1536 East Valencia Drive Fullerton, California 92831 Cathy Rumble Phone: (714) 879-6110 E-mail: cathy.rumble@nts.com Website:
More information