1 Page 1/8 Illustrations Principle diagram See enlarged drawings at the end of document Product specification mini-breakout installation cable U-VQ(ZN)H laser-optimized, bend insensitive fiber UV-resistant, metal-free, waterproof and moisture-resistant longitudinally water blocked and suitable for operation down to -40 C cable sheath: LSHF-FR (low smoke halogen free - flame retardant) cable structure: 4, 12 or 24 tight buffered fibers (dia. 0.9 ) strain relief: glasroving elements to be laid in tubes and cable ducts indoors and outdoors applicable standards: EN , ISO nd edition, IEC , IEC , EN fire behaviour: Class Dca s2 d2 acc. EN 50399* variants: number of OS2 fibers 4, 12 or 24 number of OM4 fibers 4, 12 or 24 number of OM3 fibers 4, 12 or 24 *The indication of fire protection classification is currently for your information only and becomes binding only after the assignment of the DoP number.
2 Page 2/8 General Data Fields of application Design Structured building cabling, Office Fiber to the Desk, Data center Installation cables Transmission technology Fiber optic Color heather violet Color coding fiber/ wire(s) see table Mode type of the fiber Multimode Fiber class Cable Type OM4 (ISO/IEC 11801/EN & IEC /EN A1.a.3) Mini breakout Number of cables/ cores 1 Number of fibres each cable/ wire 24 Fiber construction 50/125 µm Weight kg/km Connections/interfaces Connector technology interface 1 Free line end Connector technology interface 2 Free line end Cable sheath diameter (min. - max.) Cable sheath diameter 8.50 Cable sheath diameter in. Optical characteristics Maximum value of cable attenuation at 850 nm 3.0 db/km Maximum value of cable attenuation at 1300 nm 1.0 db/km Mechanical characteristics strain relief glasrooving elements Maximum installation load (max.) 1400 N Maximum installation load Maximum installation load in. Crush (compressive strength) 2000 N Fire load 1240 MJ/km
3 Page 3/8 Materials and material properties Material - Cable jacket LSHF-FR Bend insensitivity Flame retardancy Halogen free Metallfrei UV-resistance Longitudinal water tightness Laser-optimized Environmental conditions Temperature (min. - max.) Temperature - Storage C C Temperature - Storage F F Temperature - Operating C C Temperature - Operating F F Temperature - Installation C C Temperature - Installation F F Approvals RoHS compliant The product meets the following standards Generic cabling systems General requirements ISO/IEC Optical fibers: Product specifications Sectional specification for category A1 multimode fibres ISO/IEC (A1a.3) Optical fibers: Generic specification Cross reference table for optical cable test procedures ISO/IEC Test on gases evolved during combustion of materials from cables Determination of the halogen acid gas content IEC Determination of acidity (by measuring the ph value) and conductivity IEC
4 Page 4/8 The product meets the following standards Tests on electric and optical fibre cables under fire conditions Test for vertical flame propagation for a single insulated ISO/IEC wire or cable Test for vertical flame spread of vertically-mounted ISO/IEC bunched wires or cables Measurement of smoke density of cables burning ISO/IEC Coon test methods for cables under fire conditions Fire behaviour - class ITU-T standard Klasse Dca s2 d2 nach EN 50399* G Classifications ETIM 5.0 EC ETIM 6.0 EC Packing details Type of packaging meter / Ring or drum
5 Page 5/8 Illustrations Principle diagram
6 Page 6/8 Fiber color coding Fiber color code 1 red green blue yellow white grey brown violet 20 9 turquoise black orange pink 24 yellow w/mark per 70 white w/mark per 70 grey w/mark per 70 turquoise w/mark per 70 orange w/mark per 70 pink w/mark per 70 yellow w/mark every 35 white w/mark every 35 grey w/mark every 35 turquoise w/mark every 35 orange with w/mark every 35 pink w/mark every 35
7 Page 7/8 OpDAT fiber OM4 BR 150XXX7 General Data Transmission technology Fiber optic Mode type of the fiber Multimode Fiber class OM4 (ISO/IEC 11801/EN & IEC /EN A1.a.3) 50/125 µm Fiber construction Transmission characteristics Transmission rate up to 100 GBit IEEE 802.3ba Overfilled (OFL) modal bandwidth at 850 nm (min.) 3500 MHz * km Overfilled (OFL) modal bandwidth at 1300 nm (min.) 500 MHz * km Effective modal bandwidth (EMB) at 850 nm (min.) 4700 MHz * km Connections/interfaces Connector technology interface 1 Free line end Connector technology interface 2 Free line end Fasermanteldurchmesser ± 1.0 µm Primary coating diameter - colored 242 ± 5 µm Primary coating diameter - uncolored 250 ± 15 µm Mechanical characteristics Proof stress level min. 0.7 ( 1 %) GPa Strip force (peak) 1.3 <= Fpeak.strip <= 8.9 N Fiber cladding non-circularity max. 0.7 % Core non-circularity max. 5 % Core (MDF)-cladding concentricity error max. 1 µm Primary coating concentricity error max. 5 % Primary coating-cladding concentricity error max. 6 Inhomogeneity of OTDR measurement report at 1310 nm und 1550 nm Numerical aperture max. 0.1 db/km ± Materials and material properties Bend insensitivity
8 Page 8/8 OpDAT fiber OM4 BR 150XXX7 The product meets the following standards Generic cabling systems General requirements Data centers Powered by TCPDF ( ISO/IEC DIN EN TIA/EIA 568-C ISO/IEC Optical fibers: Measuring methods and test procedures Fibre geometry ISO/IEC Coating geometry ISO/IEC Length measurement ISO/IEC Fibre proof test ISO/IEC Coating strippability ISO/IEC Attenuation ISO/IEC Bandbreite ISO/IEC Numerical aperture ISO/IEC Gruppenlaufzeitdifferenz ISO/IEC Optical fibers: Product specifications Sectional specification for category A1 multimode fibres ISO/IEC (A1a.3) ITU-T standard G TIA/ANSI-492 AAAD
Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive
Illustrations Principle diagram Page 1/7 Product specification installation cable U-DQ(ZN)BH universal fiber optic cable for indoors/outdoors with central or stranded loose tube bend insensitive fiber
More informationData sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1
Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification connection cable I-V(ZN)HH breakout cable for direct connector termination for indoors and outdoors
More informationFiretuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red
Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU VERITAS December 2014 OFC-UT-CST
More informationMultipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24
Features and Benefits Laminated swelling glass yarns Improved rodent resistance and longitudinal water protection UV and microbe resistant Can be directly buried or installed in ducts Metal-free cable
More informationFiretuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red
OFC-UT-CST Fire resistant Armoured Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU
More informationHELKAMA. Optical Fibre Cables
1 Contents Optical fibres and their characteristics Cable constructions Cable tests Installation, jointing and terminating Manufacturing (pictures) 2 Multimode Fibre (GK) Attenuation and Bandwidth Fibre
More informationGUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.
GUCN Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection 07-07-05 v3.0 Ordering Information Belden Part Numbers Fibre Description
More informationIndustrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers
Features and Benefits Corrugated armor Mechanical protection Low-smoke/zero-halogen (LSZH ) sheath Key life-safety benefit Meets cyclic impact and chemical resistance test Superior performance Tray-rated
More informationFiber Optic Distribution Cables (6-144 Fibers)
900um Buffered Aramid Yarn Strength Members Outer 6 or 12 Subunit Central Strength Member Outer Ripcord Single Unit Cable 6-24 Multi-Unit Cable 24-144 Description: AMP NETCONNECT distribution cables are
More informationoutdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free
GUSN Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection 05-04-8 v0.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 6 4
More informationTE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET
Optic Backbone Distribution Cables 900um Buffered Aramid Yarn Strength Members Outer 6 or 12 Subunit Central Strength Member Outer Ripcord Single Unit Cable 6-24 Multi-Unit Cable 24-144 Description: TE
More informationGCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.
GCRG Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection 05-05-7 v7.0 Ordering Information Belden Part Numbers Fibre Description / count 4 8 8 4 30 36 6.5/5-OM GCRG04
More informationOPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx
fibrewave About Us Prysmian is a global market leader in optical cables, supplying a major part of the world s optical cable needs. With a strong heritage of highly advanced R&D, Prysmian is at the leading
More informationØ 1000 * 588 mm 50 kg
GUCN Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count
More informationDNVGL-CP-0402 Edition February 2016
CLASS PROGRAMME Type approval DNVGL-CP-0402 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD
More informationGOF Indoor and Outdoor Cables. Documentation VWL Version 2.2 Source Code R
GOF Indoor and Outdoor Cables Documentation VWL 064.504 Version 2.2 Source Code R GOF Installation Cables Cable matrix / overview Source code: R Use Indoor In- / Outdoor Outdoor Type of cable Breakout
More informationGOF Indoor and Outdoor Cables. Documentation VWL Version 1.1 Source Code M
GOF Indoor and Outdoor Cables Documentation VWL 064.503 Version 1.1 Source Code M GOF Installation Cables Cable matrix / overview Source code M Use Indoor In- / Outdoor Outdoor Type of cable Breakout Mini-
More informationGUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.
GUSN Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 16 24 62.5/125-OM1
More informationSumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003
Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber PureGuide SM Optical Fiber, TIA Type IVd Issued: November 2003 78 Alexander Drive, Research Triangle Park, NC 27709 Phone
More informationDuct Cable GYTS-144B1.3
Optical Fibre Cable Technical Specification Duct Cable GYTS-144B1.3 Xcom Ltd All rights reserved 1. Scope This Specification covers the design requirements and performance standard for the supply of optical
More information2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK
PART 1 GENERAL 1.01 SCOPE OF WORK SECTION 27 12 23 FIBER OPTIC DATA NETWORK A. Furnish, install, terminate, and test all fiber optic equipment and cabling necessary for a complete and functional data highway
More informationSumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber
Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber PureGuide -LA SM Optical Fiber, TIA Type IVd ITU G.655 C and D Compliant Issued:
More informationindustry solutions: military
industry solutions: military MC industry Solutions: Military A tradition of leadership in technology, product performance for military applications Optical Cable Corporation is a leading manufacturer of
More informationGUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.
GUSA Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 62.5/125-OM1
More informationGBRD. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits
GBRD Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 24 36 48 60 72 62.5/125-OM1 GBRD124 GBRD136 GBRD148 GBRD160
More informationOptical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3
VersionGYTA-72B1.3 Optical Fibre Cable Technical Specification Duct Cable GYTA-72B1.3 Yangtze Optical Fibre and Cable Joint Stock Limited Company All rights reserved www.yofc.com All Rights Reserved Copyright
More informationEasy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm).
GCDG Multi Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)H(SR)H Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count
More informationCHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES
THE CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES 17th September 2002 Botanical Gardens Birmingham The Way We Were 1GbE and 10GbE OF Categories Channel Design Cleaning SFF Connecting Hardware Testing
More informationFibre Specification Standards
Fibre Specification Standards User Manual The most important thing we build is trust Cobham Wireless - Coverage Table of Contents 1. Single-mode Fibre to ITU-T Recommendation G.652 3 2. SC/APC Mated Pair
More informationTELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS
TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS TKF TECHNOLOGICAL LEADERSHIP IN CONNECTIVITY SOLUTIONS Since its establishment in 90 TKF developed from a cable producer to a leading
More informationCopper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.
Product Specification 108-93018 25/Aug/2011 Rev H Copper LAN cable 1. SCOPE 1.1. Content This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. 2. APPLICABLE DOCUMENTS
More informationSPECIAL ELECTRICAL AND OPTICAL CABLES
SPECIAL ELECTRICAL AND OPTICAL CABLES INTRODUCTION The new high-speed trains and the sensible increase of the traffic, with congested lines, is the result of the latest development of the rail sector.
More informationSTANDARD CONFORMANCE
STANDARD CONFORMANCE IEC 60331-11, Tests for electric cables under fire conditions- Circuit integrity- Fire alone at a flame temperature of at least 750C IEC 60331-21, Tests for electric cables under fire
More informationDNVGL-CP-0401 Edition February 2016
CLASS PROGRAMME Type approval DNVGL-CP-0401 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD
More information--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T
Translated English of Chinese Standard: YD/T1447-2013 www.chinesestandard.net Sales@ChineseStandard.net COMMUNICATION INDUSTRY STANDARD OF THE PEOPLE S REPUBLIC OF CHINA YD ICS 33.180.10 M 33 Replacing
More information13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION
13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION This specification is property of SEC and subject to change or modification
More informationVTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links
VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links TB Number 004 This bulletin is supplied for information only and is intended to provide
More informationDNVGL-CP-0399 Edition March 2016
CLASS PROGRAMME Type approval DNVGL-CP-0399 Edition March 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD
More informationFiber Optic Patch Cord and Pigtails
Fiber Optic Patch Cord and Pigtails Description The optical fiber patch cords are fitted at both ends with same connector types or different connector types. Our fiber optic patch cords are ultra reliable
More informationTraction Cable Radox 3 GKW
General Properties : Excellent high temperature, low temperature, ozone and weathering resistance, zero halogen, flame retardant, solder iron resistant, easily strippable, flexible. Application : Single
More informationFTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)
TE Connectivity's (TE) FTTX infrastructure solutions are designed from the ground up to meet the unique requirements of FTTX networks. Designed for operational efficiency and scalability, TE s FTTX solutions
More informationINTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD
INTERIM EUROPEAN I-ETS 300 644 TELECOMMUNICATION June 1997 STANDARD Source: ETSI TC-TM Reference: DI/TM-01021 ICS: 33.020 Key words: Fibre, cable, optical, transmission Transmission and Multiplexing (TM);
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Presley House Presley Way Crownhill Milton Keynes MK8 0ES United Kingdom Contact: Jeremy Hodge Tel: +44 (0) 1908 267300 Fax: +44 (0) 1908
More informationFibre Optic Cable. Catalogue.
Fibre Optic Cable Catalogue www.fibrefab.com About The FibreFab Group FibreFab Established in 1992, FibreFab is a leading provider of fibre optic connectivity products used in data communications and Telecommunication
More informationSECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING
SECTION 27 13 23 COMMUNICATIONS OPTICAL FIBER PART 1 - GENERAL 1.1 SUMMARY A. Section Includes the following: 1. 50/125-micrometer, optical fiber cabling. 2. Cable connecting hardware, termination panels,
More informationFlame Retardant Overall Screened Instrumentation Cables (multicore)
Flame Retardant Overall Screened Instrumentation Cables (multicore) RE-2X(St)H RE-2X(St)HSWAH LSZH Outer Sheath Tinned Copper Drain Wire LSZH Inner Sheath XLPE Insulation Plain Annealed Copper Aluminium/polyester
More informationPRODUCT CATALOGUE Norröna
PRODUCT CATALOGUE Norröna WWW.SCANKAB.COM Table of contents MARINE AND OFFSHORE CABLES 1 TOXFREE XZ1-K (AS) - 0.6/1 kv 1 TOXFREE MARINE XO2TCuZ1-K (AS) - 150/250 V 5 4x2xAWG 24/1 CAT6 S/FTP LSZH-SHF1 -
More informationSTANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE
ANSI/ICEA S-104-696-2001 STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE Publication S-104-696 First Edition - September 2001 Published By Insulated Cable Engineers Association, Inc. Post Office Box 1568
More informationFire Safety Fire Resistant Building Components
Fire Safety Fire Resistant Building Components NBN 713-020 1968 Fire fighting - Fire performance of building materials and products - Fire resistance of building materials NBN 713-020/A1 1982 Protection
More informationHigh Performance LSZH Fire Resistant Cable
High Performance LSZH Fire Resistant Cable www.cavicel.com 104/2 FIRECEL SR 114H is the long and well established CAVICEL fire resistant cable in the market, since many years. These cables are third party
More informationfire resistant cables
Building Technology fire resistant cables Special electrical and optical cables www.tecnikabel.com Special electrical and optical cables 2 INTRODUCTION Structured cabling solutions. Tecnikabel can provide
More informationProduct Specification CAT 6 UNSHIELDED PATCH CORDS
Product 108-93017 Specification 23/Nov/06 Rev. A CAT 6 UNSHIELDED PATCH CORDS 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for NETCONNECT
More informationHands-On Fiber Optics ISP/OSP - Advanced Combo- Tech
Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech Course Description This Hands-On 3-day course has been customized to provide technicians with a practical understanding of fiber optic theory and fiber
More informationOPTICAL FIBER SOLUTIONS
www.ofsoptics.com/medical OPTICAL FIBER SOLUTIONS FOR YOUR MEDICAL DEVICE ISO 9001 and 13485 Certified FDA Good Manufacturing Practices USP Class VI and ISO10993 for Biocompatibility Low Bioburden Assembly
More informationSpecial Provision No. 683S28 December 2017
FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE - Item No. FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE (TEMPORARY) - Item No. Special Provision No. 683S28 December 2017 1. SCOPE
More informationClearlite Photonic Fibers
Clearlite Photonic Fibers Fiber Name Operating Wavelength MFD at Operating Wavelength Beat Length at Operating WL Clad/Coating Diameter Order by Part Number TruePhase 980 Micro TruePhase 980 400 TruePhase
More informationMT-RJ Optical Fiber System Field Testing
MT-RJ Optical Fiber System Field Testing Table of Contents INTRODUCTION... 3 TEST JUMPERS... 4 LAUNCH CONDITIONS... 4 MT-RJ TEST KITS... 5 MT-RJ SYSTEM TESTING: Fixed transmit and receive (SC or ST-style)
More informationSpecification No.CSC-131/R-1/DH//UH/P&D/ Technical Specifications. for 24 Fiber/48 Fiber Unarmoured. Underground Fibre.
Specification No.CSC-131/R-1/DH//UH/P&D/2016-17 Technical Specifications for 24 Fiber/48 Fiber Unarmoured Underground Fibre Optic Cabling Issue Month:June-2016 (CSC Amendment date 14.06.2016) Common Specification
More informationLloyd s Register Type Approval System Test Specification Number 3
Working together for a safer world Lloyd s Register Type Approval System Test Specification Number 3 July 2015 Performance Test Specification for Equipment to be used in Marine Applications: Electric Cables
More informationCATEGORY 6A FTP RJ45 SOLUTION
CATEGORY 6A FTP RJ45 SOLUTION Clipsal titanium Patch Cord Clipsal titanium LSZH Patch Cord Clipsal titanium Keystone Jacks Clipsal titanium Modular Jacks Clipsal titanium Patch Panels Clipsal titanium
More informationAFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)
Page 1 / 7 Construction and tests. Standards: UNE 211025 Compliance with the Low Voltage Directive (LVD): 2014/35 / EU Construction Products Regulation (CPR) - Regulation (EU) Nº 305/2011: Reaction to
More informationFiber Tes)ng 101 Essen)als Every Network Analyst Needs to Know. David S(llwell BCNET Oscar Rondon BCNET Gwenn Amice - EXFO
Fiber Tes)ng 101 Essen)als Every Network Analyst Needs to Know David S(llwell BCNET Oscar Rondon BCNET Gwenn Amice - EXFO Workshop format The Workshop is going to start with three short lecture style power
More informationLink loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team
Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team INTRODUCTION The OTDR is a very efficient tool for characterizing the elements on
More informationFire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION
Fire alarm cables for highest safety requirements TRADITION INNOVATION PASSION Datwyler Datwyler Cabling Solutions is an internationally operating company with its headquarters in Switzerland and affiliates
More informationFIRE RESISTANT CABLES
Conducting Value The Last Cable Standing FIRE RESISTANT CABLES 100/7b ISO 9001:2008 Certificate No. CS1-249 MANAGEMENT SYSTEMS Assessed to ISO 9001:2008 Cert/LPCB ref. 217 GOST ISO 9001-2011 (ISO 9001:2008)
More informationFiberExpress Solutions
7.2.1-A 7.2.1-B 7.2.1-C 7.2.1-D Simplex Patch Cord Duplex Patch Cord Hybrid Patch Cord Single-ended (pigtails) AX200057 Patch Cord Multimode SC Duplex DESCRIPTION FiberExpress Simplex and Duplex Patch
More informationHands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing
Hands-On Splicing, Termination & Testing BICSI CECs This course has been approved for CEC credits by BICSI. Please read below for a breakdown of the credits that we offer for this course. For more information
More informationPhotovoltaic Cables EN H1Z2Z2-K
Photovoltaic Cables EN 50618 H1Z2Z2-K COMPANY PROFILE Caledonian, established in 1978, offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different
More informationCONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE
CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE Carol Harris, EMEA Product Manager WHITE PAPER Molex Connected Enterprise Solutions EXECUTIVE SUMMARY Combustible construction materials
More informationSTAND OUT FROM THE CROWD. Bisham Abbey, 14th May 2002 INTRODUCTION. Work Smart FIA. The Fibreoptic Industry Association STAND OUT FROM THE CROWD
INTRODUCTION Work Smart FIA STAND OUT FROM THE CROWD 14th May 2002, Bisham Abbey Mike Gilmore 2002 Fibreoptic Industry Association Work Smart www.it-cabling.com www.e-readybuilding.com PO Box MT65, LEEDS,
More informationFibre optic media options and trends
Fibre optic media options and trends Presented by D Stockton & P Lascelles of Miniflex Ltd, branded as m2fx 23 February 2012 1 Contents Cable constructs Indoor/outdoor LSZH Armouring Micro Bends Singlemode,
More information4120 Fire Alarm Network Reference
4120 Fire Alarm Network Reference Features Autocall 4120 Fire Alarm Network communications are available for wired or fiber optic connections Wired communications are available on Network Interface Cards
More informationTYPE APPROVAL CERTIFICATE
TYPE APPROVAL CERTIFICATE Certificate No: TAE00000GG Revision No: 2 This is to certify: That the Data transmission cables and systems with type designation(s) MGD Cat 3, MGD Cat 5, Cat 5e, MGD cat 6, Cat
More informationCompact Module. Category 6A FTP Cabling System 1.1
Updated 24/09/12 Compact Module Cat 6A performance Suitable for 10-Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro Modules and blanks Individually QA tested Easy
More informationOFS IV Optical Fibre System
OFS IV Optical Fibre System FOR ALL FIBRE OPTIC USERS Fibre optic training has assumed great importance in today s world of widespread fibre optic usage whether in telecommunications or railways, industrial
More informationÜntel is ready for CPR
2016 Üntel is ready for CPR Hakan Kubas Marketing Manager 01.11.2016 Construction Products Regulation What is the CPR? The Construction Products Regulation (CPR) lays down conditions for the placing or
More information(Notices) EUROPEAN COMMISSION
14.8.2012 Official Journal of the European Union C 245/1 IV (Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION Commission communication in the framework
More informationinfrastructure for 10, 40 and 100Gbits/s readiness
Field Testing of fiber optic infrastructure for 10, 40 and 100Gbits/s readiness Christian Schillab Product Manager Media Test Fluke Networks Europe Member BritishStandards Institute Working Group TCT 7/
More informationReflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010
Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010 Adrian Young Sr. Customer Support Engineer Foreword Reflectance is measured using an Optical
More informationOPTICAL FIBER SOLUTIONS
RightWave Erbium-Doped Optical Fiber Critical component for the amplification of optical transmission signals A Furukawa Company Broad portfolio suited to diverse needs Proven product uniformity, quality
More informationFIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.
FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No. Special Provision No. 683S01 December 2017 1. SCOPE This Special Provision covers
More informationFujikura-70S Single Fibre Fusion Splicer
Fujikura- Single Fibre Fusion Splicer Features Core-to Core alignment, Dual Axis observation system. World s quickest splicing 6sec. / tube-heating 9sec. Minimal manual operation. Splice in 4 steps. Multi-functional
More informationAcceptance Requirements. Fibre Optic Systems. Revised 12/2017. December 5th, Alexander Kölbel
December 5th, 2017 Acceptance Requirements Fibre Optic Systems Revised 12/2017 Alexander Kölbel +49 6190 8880-40 alexander.koelbel@datwyler.com Dätwyler Cables GmbH, Auf der Roos 4-12, 65795 Hattersheim,
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO/IEC 14763-3 First edition 2006-06 Information technology Implementation and operation of customer premises cabling Part 3: Testing of optical fibre cabling Reference number ISO/IEC
More informationThe Quality Connection. BETAflam Fire Resistant Safety Cables
The Quality Connection BETAflam Fire Resistant Safety Cables BETAflam Contact Your personal customer number To offer you a more efficient service, we kindly ask you to mention your personal customer number
More informationSTANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE
STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE Publication # ICEA S-104-696 Second Edition March 2013 2013 by ICEA INSULATED CABLE ENGINEERS ASSOCIATION, Inc. STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER
More informationBelcom Cable excellence engineered through quality. CPR Construction Products Regulation
CPR Construction Products Regulation Index Construction Products Regulation... 3 What is the Construction Products Regulation (CPR)... 4 What is the objective of the CPR... 4 Who does the application of
More informationWHAT MAKES PRYSMIAN CABLES DIFFERENT?
WHAT MAKES PRYSMIAN CABLES DIFFERENT? UALITY PRYSMIAN PERFORMANCE TEST TALLATION SAFETY INSTALL N IN ECONOMIC ADVANTAG PRYSMIAN PERFORMANCE TEST Prysmian Group presents Prysmian Performance Test (PPT):
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61892-4 First edition 2007-06 Mobile and fixed offshore units Electrical installations Part 4: Cables Commission Electrotechnique Internationale International Electrotechnical
More informationFIRST-CLASS IN TRAINS
FIRST-CLASS IN TRAINS Powered by TCPDF (www.tcpdf.org) Powered by TCPDF (www.tcpdf.org) Advanced fire protection for railway vehicles: hazard level 2 & 3 according to EN 45545 Effectively prevents moisture
More informationTelephone and Data Structured Wiring
Data Specification Category 6A General Telephone and Data Structured Wiring The Electrical Sub-Contractor shall employ a specialist sub-contractor to provide the following systems:- Manufacturer System
More informationThe Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise
The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise 1 The purpose of the exercise...2 2 Background...2 2.1 Introduction to scattering and attenuation...2 2.2 Introduction to
More informationFUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES
Cables Limited MADE IN IRELAND SINCE 1934 QUALITY APPROVED CABLES IDH CABLES LIMITED FUMEGUARD TM LOW SMOKE HALOGEN FREE CABLES The longest-running original range of low voltage, low smoke, halogen free
More informationAttenuators. Fiber Optic Products Catalog. Singlemode Build Out Attenuators. Product Facts. Applications. Customizable Features. Available Collateral
Attenuators Build Out Attenuators Product Facts A range of fixed attenuation values. Standard values of 1 through 20 and 25dB UPC and APC offer Excellent Return Loss LC, SC, FC, ST, and D4 styles Attenuation
More informationThe Quality Connection. Cable fire protection Flammability tests on ship and offshore cables
The Quality Connection Cable fire protection Flammability tests on ship and offshore cables Fire protection 2 Marine technologies product range The right cable for any application. Commercial shipbuilding
More informationNew European Cable Testing and Classification
New European Cable Testing and Classification THE BENCHMARK IN FIRE TESTING New European Cable Testing and Classification Cables will be tested using 5 test methods, and classified by extending the provisions
More informationIEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.
67 POWERFLEX RV-K POWERFLEX RV-K Industrial flexible cable for power transmission. 1 IEC 60502-1 - UNE 21123-2 DESIGN 1. Conductor 2 Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.
More informationCaledonian Flame Retardant Coaxial Cables
Caledonian Flame Retardant Coaxial Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant RG59 Coaxial cables LSZH Outer Sheath Tinned Copper Braid Aluminium+polyester/Aluminium Tape
More informationSingle core cables with reduced wall thickness
Product description: RADOX 4 GKW -AX 1800V M Nominal voltage: Hazard level: Single core cables with reduced wall thickness 1800 / 3000 V AC M (extra low temperature, extra oil and extra fuel resistant)
More informationBasic Professional Fiber Optic Installation
Basic Professional Fiber Optic Installation QUICK SUMMARY Length: 32 hours; or 40 hours with Fiber Optic Association CFOT certification Hands-on Activities: 40 activities, 70-75 % Text/Field Reference:
More information