for CE 134 CCSAUS certificate Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title page EN

Size: px
Start display at page:

Download "for CE 134 CCSAUS certificate Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title page EN"

Transcription

1 Title page CCSAUS certificate: EN for EX Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland CCSAUS certificate

2 THIS PAGE INTENTIONALLY LEFT BLANK

3 CCSAUS instructions specific to hazardous area installations YY5 to YY9 The following instructions relevant to safe use in a hazardous area apply to equipment covered by the CCSAUS certificate. 1 The certification marking is as follows: Class I, Division 1, Groups A, B, C, D Ex ia IIC T6 T1 Ga Class 1, Zone 0 AEx ia IIC T6 T1 Ga Reference drawing PZ Class I, Division 2, Groups A, B, C, D Ex na IIC T6 T1 Gc Class 1, Zone 2 AEx na IIC T6 T1 Gc Reference drawing PZ The equipment may be used in Zones 0, 1 and 2 with flammable gases and vapours, with apparatus groups IIA, IIB and IIC, and with temperature classes T1 to T6. Temperature classes depend on the operating temperatures of the sensor, cable and signal conditioner (see 4). 3 The equipment may also be used in Division 1 and Division 2 with Groups A, B, C, D. 4 The equipment is only certified for use in ambient temperatures in the range as specified below and should not be used outside this range. Sensor operating temperature: 70 to +350 C. Cable operating temperature: 54 to +260 C. Conditioner operating temperature: 54 to +125 C. Temperature classes depend on the operating temperatures of the sensor, cable and signal conditioner: Part T6 T5 T4 T3 T2 T1 Sensor +80 C +95 C +130 C +195 C +290 C +350 C Cable +80 C +95 C +130 C +195 C +260 C --- Conditioner +65 C +80 C +115 C +125 C Installation shall be carried out in accordance with the applicable code of practice by suitably trained personnel. 6 There are no special checking or maintenance conditions. 7 With regard to explosion safety, it is not necessary to check for correct operation. 8 The equipment contains no user-replaceable parts and is not intended to be repaired by the user. Repair of the equipment is to be carried out by the manufacturer, or their approved agents, in accordance with the applicable code of practice. 9 Repair of this equipment shall be carried out in accordance with the applicable code of practice. 10 If the equipment is likely to come into contact with aggressive substances, such as acidic liquids or gases that may attack metals or solvents that may affect polymeric materials, then it is the responsibility of the user to take suitable precautions that prevent it from being adversely affected, thus ensuring that the type of protection is not compromised. 11 WARNING EXPLOSION HAZARD DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS AREA IS KNOWN TO BE NON-HAZARDOUS. CCSAUS certificate

4 Certificate of Compliance Certificate: Project: Master Contract: Date Issued: September 22, 2015 Certificate: Master Contract: Project: Date Issued: September 22, 2015 Issued to: Meggitt SA Rte de Moncor 4 Villars-sur-Glane, 1752 Switzerland Attention: Carlo Pellegrinelli The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. PRODUCTS Issued by: Sripriya Kalyanasundaram CLASS PROCESS CONTROL EQUIPMENT - Intrinsically Safe and Non- Incendive Systems For Hazardous Locations. Class I, Division 1, Groups A, B, C and D Ex ia IIC T6..T1 Ga Part T6 T5 T4 T3 T2 T1 Sensor +80 C +95 C +130 C +195 C +290 C +350 C Cable +80 C +95 C +130 C +195 C +260 C -- Conditioner +45 C +60 C +95 C +125 C CLASS PROCESS CONTROL EQUIPMENT For Hazardous Locations Class I, Division 2, Groups A, B, C and D Ex na IIC T6..T1 Gc CLASS PROCESS CONTROL EQUIPMENT - For Hazardous Locations, Certified to US standards. Class I, Division 2, Groups A, B, C and D Class 1, Zone 2, AEx na IIC T6..T1 Gc CE134 Accelerometer PNR YY5 to YY9, YY depends on the connector type and cable length (YY = 00 to 99) Entity parameters: U 28V, P 224 mw Note Sensor Operating Temperature: -70 C to +350 C Cable Operating Temperature: -54 C to +260 C Conditioner Operating Temperature: -54 C to +125 C Temperature classes depend on operating temperature of conditioner, cable and sensor: Part T6 T5 T4 T3 T2 T1 Sensor +80 C +95 C +130 C +195 C +290 C +350 C Cable +80 C +95 C +130 C +195 C +260 C -- Conditioner +65 C +80 C +115 C +125 C CLASS PROCESS CONTROL EQUIPMENT - Intrinsically Safe and Non Incendive Systems For Hazardous Locations, Certified to US standards. Class I, Division 1 Groups A, B, C and D Class 1, Zone 0, AEx ia IIC T6..T1 Ga CE134 Accelerometer PNR YY5 to YY9, YY depends on the connector type and cable length (YY = 00 to 99) Entity parameters: Ui : 28V; Ii : 100mA; Pi : 700mW; Ci : 0; Li : 0 DQD 507 Rev Page 1 DQD 507 Rev Page 2 2 CCSAUS certificate

5 Certificate: Project: Master Contract: Date Issued: September 22, 2015 Certificate: Project: Master Contract: Date Issued: September 22, 2015 APPLICABLE REQUIREMENTS Marking is engraved on product metallic body. CAN/CSA-C22.2 No August 2011 General requirements Canadian Electrical Code, Part II CAN/CSA-C22.2 No (May 2012) CAN/CSA-C22.2 No :11 (December 2011) CAN/CSA-C22.2 No :14 (February 2014) CAN/CSA-C22.2 No :12 Third Edition Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use Part 1: General Requirements Explosive atmospheres Part 0: Equipment General requirements Explosive atmospheres Part 11: Equipment protection by intrinsic safety i Electrical apparatus for explosive gas atmospheres Part 15 CAN/CSA-C22.2 No Intrinsically Safe and Non- Incendive Equipment for use in Hazardous location CAN/CSA-C22.2 No.213-M Non-Incendive Electrical Equipment for Use in Class I, Division 2 Hazardous Locations ANSI/UL Explosive atmospheres Sixth Edition (July 26, 2013) Part 0: Equipment General requirements ANSI/UL Explosive Atmospheres Part 15: Type of protection n ANSI/UL Explosive Atmospheres Sixth Edition (September 6, 2013) Part 11: Equipment Protection by Intrinsic Safety i ANSI/UL Safety Requirements for Electrical Equipment for Third Edition (May 11, 2012) Measurement, Control, and Laboratory Use Part 1: General Requirements ANSI/UL Intrinsically Safe Apparatus and Associated Apparatus for Use Eighth Edition in Class I, II and III, Division I, Hazardous Locations ANSI/ISA Non-Incendive Electrical Equipment for Use in Class I and II, MARKINGS Division 2 and Class III, Divisions 1 and 2 Hazardous Locations Manufacturer s name : MEGGITT SA Model Number: As specified in the products section. Marking as specified in the products section. Note to say Refer dwg PZ8584, Refer drawing PZ8585 (for Electrical Entity parameters: As specified in the products section.) Serial Number and Manufacturing date in MMYY format. COC number : CSA The CSA Mark with C and US indicators as shown on the Certificate of Conformity. Note: See Instructions for ambient temperature range and warnings. The manufacturer is required to apply the following markings: Products shall be marked with the markings specified by the particular product standard. Products certified for Canada shall have all Caution and Warning markings in both English and French. Additional bilingual markings not covered by the product standard(s) may be required by the Authorities Having Jurisdiction. It is the responsibility of the manufacturer to provide and apply these additional markings, where applicable, in accordance with the requirements of those authorities. The products listed are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US (indicating that products have been manufactured to the requirements of both Canadian and U.S. Standards) or with adjacent indicator 'US' for US only or without either indicator for Canada only. DQD 507 Rev Page 3 DQD 507 Rev Page 4 CCSAUS certificate

6 Supplement to Certificate of Compliance Certificate: Master Contract: The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced Certificate. Product Certification History Project Date Description September 22, 2015 Original Certification of PNR YY5 to YY9 DQD 507 Rev Page 1 4 CCSAUS certificate

7 CCSAUS certificate

8 6 CCSAUS certificate

ccsaus certificate: for GSI 127 Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title Page

ccsaus certificate: for GSI 127 Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title Page Title Page ccsaus certificate: EN 70001999 for EX Meggitt SA Route de Moncor 4 PO Box 1616 CH - 1701 Fribourg Switzerland ccsaus certificate 70001999 www.meggittsensingsystems.com www.vibro-meter.com THIS

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2185148 (217005) Issued to: RAE Systems, Inc. 3775 North First St San Jose, California 95134 USA Attention: James Pan The products listed below are eligible to bear

More information

Certificate of Compliance

Certificate of Compliance FF0002 Certificate of Compliance Certificate: 2792948 Issued to: Siemens Canada Limited 1954 Technology Drive Peterborough, ON K9J 7B1 Canada Attention: Mr. Lee Rogers The products listed below are eligible

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70033893 (166720) Issued to: WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Str 30 Klingenberg, 63911 GERMANY Attention: Uwe Schmidt The products listed below

More information

Certificate of Compliance

Certificate of Compliance FF0002 Certificate of Compliance Certificate: 70009779 Issued to: Pepperl+Fuchs GmbH Lilienthalstrasse 200 Mannheim, 68307 GERMANY Attention: Martin Holdefer The products listed below are eligible to bear

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The

More information

Certificate of Compliance

Certificate of Compliance FF02 Certificate of Compliance Certificate: 70068210 Issued to: Cascade Technologies Ltd Glendevon House, Castle Business Park, Stirling, Scotland. UNITED KINGDOM FK9 4TZ Attention: Mr M Douglas. The products

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70000097 Project: 70125347 Issued to: Thermo Engineering S.r.l Via Giuseppina, 19 26030 Malagnino (CR) Italy Attention: Mr. BOZZETTI The products listed below are

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1469131 (LR 103134) Master Contract: 184981 Issued to: Industrial Monitoring Instr. (IMI) A Div. of PCB Piezotronics, Inc. 3425 Walden Ave Depew, NY 14043 USA Attention:

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Issued to: GE Intelligent Platforms 240 The Village Butterfield Business Park Bedfordshire, Luton LU2 8DL United Kingdom Attention: John Purdy The products listed below are eligible

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2557738 Master Contract: 256526 Issued to: Bartec Varnost d.o.o Cesta 9 avgusta 59 Zagorje ob Savi, 1410 Slovenia Attention: Janez Gajski The products listed below

More information

Certification Supplement Manual

Certification Supplement Manual PROCESS ANALYSERS SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 2 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EC DECLARATION OF CONFORMITY

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70067850 Date Issued: July 28, 2017 Issued to: Otis Instruments, Incorporated 301 S. Texas Ave. Bryan, Texas, 77803 USA Attention: Nicholas Sandera The products listed

More information

Certification Supplement Manual

Certification Supplement Manual PROCESS ANALYSERS SERVOTOUGH Oxy Gas Analyser Certification Supplement Manual Part Number: 01910008B Revision: 9 Language: UK English This page intentionally blank SERVOTOUGH Oxy Certification Supplement

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2325079 Issued to: Cooper Crouse Hinds GmbH Neuer Weg Nord 49 69412 Eberbach Germany Attention: Mr Günther The products listed below are eligible to bear the CSA

More information

Certificate of Compliance

Certificate of Compliance FF0002 Certificate of Compliance Certificate: 2708418 Issued to: Gems Sensors Inc. 1 Cowles Road Plainville, CT 06062 USA Attention: Mr. Philip I. Draper The products listed below are eligible to bear

More information

Certification Supplement Manual

Certification Supplement Manual SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 5 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EU DECLARATION OF CONFORMITY 3 EUROPEAN

More information

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon INSTRUCTION MANUAL Minialite Intrinsically Safe Round LED This instruction sheet describes installations which conform to EN60079:Part14:2008 Electrical Installation in Hazardous Areas. When designing

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1655492 (219995) Issued to: R.C. Systems Co., Inc. 8621 Hwy 6 Hitchcock, Texas 77563 USA Attention: Roger Carter The products listed below are eligible to bear the

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1238566 Issued to: Rosemount Analytical Inc. Solon Research & Development Ctr 6565-P Davis Industrial Pkwy Solon, OH 44139 USA Attention: Dana Crowley The products

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1563164 Issued to: Metal Samples Company, A Div. of Alabama Specialty Products, Inc. 152 Metal Samples Rd PO Box 8 Munford, Alabama 36268 USA Attention: Bala Palanisamy

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1055868 (LR 44092) Master Contract: 152450 Issued to: Micro Motion Incorporated 7070 Winchester Cir Boulder, CO 80301 USA Attention: Ray C. Stengl The products listed

More information

4) Intrinsic Safety Certification

4) Intrinsic Safety Certification INSTRUCTION MANUAL Minialert Intrinsically Safe Round Combined Unit Section Volume Control Tone Generator S2 S3 Tone Selection Switches Fig 1 Simplified block diagram The combined unit is CE marked for

More information

CA 134. Piezoelectric accelerometer. IECEx NEPSI TIIS KGS. » From the Vibro-Meter product line» Vibration monitoring over a wide temperature

CA 134. Piezoelectric accelerometer. IECEx NEPSI TIIS KGS. » From the Vibro-Meter product line» Vibration monitoring over a wide temperature FEATURES» From the Vibro-Meter product line» Vibration monitoring over a wide temperature range, including cryogenic temperatures» Differential output» Hermetically welded» Certified for use in potentially

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2007104 Master Contract: 223077 Issued to: Purge Solutions 2201 North Highway 35 Bypass Suite C Alvin, TX 77511 USA Attention: Wallace Trochesset The products listed

More information

An Urgent Bulletin from CSA Group

An Urgent Bulletin from CSA Group An Urgent Bulletin from CSA Group Hazardous Locations Products No. 28 (Supersedes Electrical Certification Notice No. 544A) Date: January 3, 2018 See Attachment 1 for Effective Dates. See Attachment 1

More information

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION Special Safety Instruction en RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION Contents TankRadar Pro European ATEX Directive Information............................... 2 ATEX marking and Ex Certification

More information

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx Piezoelectric accelerometer with integrated electronics FEATURES» From the Vibro-Meter product line» Designed for medium temperature industrial applications: 55 to 115 C» Sensitivity: 100 mv/ g» Frequency

More information

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Rosemount 3490 Series 4 20 ma + HART Compatible Controller 00825-0200-4841, Rev AB Rosemount 3490 Series 4 20 ma + HART Compatible Controller Failure to follow safe installation guidelines could result in death or serious injury The Rosemount 3490 Series Control

More information

MICROpeL 75 Combustible Gas Sensor Part Number: PM

MICROpeL 75 Combustible Gas Sensor Part Number: PM MICROpeL 75 Combustible Gas Sensor Part Number: PM759-000 Key Features & Benefits: ATEX, UL and CSA Approvals Withstands EN/IEC 60079-0 impact test Enhanced H 2 S and silicone poison resistance Reduced

More information

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control. E2S Datasheet 1.2.1 v10a ISmA1 ISminialarm The ISmA1 is a compact, 100dB(A) alarm sounder. Approvals include ATEX, IECEx and GOSTR for Zone 0 applications and FM approval for Class I Division 1 and Class

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1182963 (066027_0_000) Issued to: WIKA Instruments Ltd. 3103 Parsons Rd Edmonton, Alberta T6N 1C8 CANADA Attention: Robert Woo The products listed below are eligible

More information

Certificate of Compliance

Certificate of Compliance FF0002 Certificate of Compliance Certificate: 2385571 Project 2447891 Issued to: Mine Safety Appliances 1000 Cranberry Woods Drive Cranberry Township, PA 16066 USA Issued by: Jocelyn Jens Product Group

More information

Certificate of Compliance

Certificate of Compliance FF0002 Certificate of Compliance Certificate: 70044220 Issued to: Cascade Technologies Limited Glendevon House Castle Business Park Stirling FK9 4TZ UK Attention: Mr. Marcus Douglas The products listed

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 8 mm non-flush Stainless steel housing Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 8 mm

More information

Certificate of Compliance

Certificate of Compliance FF0002 Certificate of Compliance Issued to: Exheat Ltd. Threxton Road Industrial Estate Watton Thetford Norfolk, IP25 6NG UNITED KINGDOM Attention: James Pettman The products listed below are eligible

More information

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O****** Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O****** CSA 14.2662675 Ex ia IIC T6 Ga, Gb 0044 Document ID: 48924 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical

More information

IRceL CH4 Methane (CH 4

IRceL CH4 Methane (CH 4 Product Datasheet IRceL CH4 Methane Sensor Document Purpose The purpose of this document is to present the performance specification of the IRceL CH4 Methane gas sensor. This document should be used in

More information

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt Airo Wireless Intrinsically Safe White Paper Written By: David Schmitt Intrinsically Safe Cell Phone/Smartphone/PDA Intrinsically Safe (IS) is a protection certification for safe operation with electronic

More information

Rosemount 752 Fieldbus Remote Indicator

Rosemount 752 Fieldbus Remote Indicator Product Data Sheet Rosemount 752 Rosemount 752 Fieldbus Remote Indicator ROSEMOUNT 752 DELIVERS: Two-wire segment powered device Displays up to 8 values Link Master Capability Optional PID, Characterizer,

More information

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74 AM54 Instruction Bulletin North American Installation Addendum Document Number PN25016 Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

More information

User s Manual YTA610 and YTA710 NEPSI Certification

User s Manual YTA610 and YTA710 NEPSI Certification User s Manual YTA60 and YTA70 NEPSI Certification [Option code: /NS, /NS5 and /NF] st Edition . INTRODUCTION Thank you for purchasing the YTA60 and YTA70 Temperature transmitters. This manual contains

More information

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma, User s Manual YTA Series Temperature Transmitters [Style: S3] Manual Change No. 10-008 Please use the attached sheets in the following manuals when the product is with /KU2 option and EN60000 Series based

More information

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm 0102 Model Number Features 4 mm non-flush Accessories BF 12 Mounting flange, 12 mm Technical Data specifications Switching element function NAMUR, NO Rated operating distance s n 4 mm Installation non-flush

More information

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

4P75 CiTipeL Combustible Gas Sensor Part Number: PM Product Datasheet 4P75 Document Purpose The purpose of this document is to present the performance specification of the 4P75 CiTipeL. This document should be used in conjunction with Operating Principles

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate IECEx

More information

INSTRUCTION MANUAL (ATEX)

INSTRUCTION MANUAL (ATEX) INSTRUCTION MANUAL (ATEX) ISmA1M Minialarm Intrinsically Safe Round ISmA1M Volume Control Tone Generator S3 Tone Selection Switches Fig 1 Simplified block diagram The ISmA1M sounder is CE marked for compliance

More information

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2595099 (LR 7189-177) Master Contract: 164196 Project: 2697346 Date Issued: January 28, 2014 Issued to: Tyco Electronics Corporation 2901 Fulling Mill Rd Mail Stop

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush

More information

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0. Selection of Explosion Protected Equipment for Hazardous Locations Compiled by: Pieter Coetzee ZONE 2 ZONE 0 ZONE 1 Be safe be Ex Contents Introduction Occupational Health and Safety Act. (Act 85 of 1993)

More information

E2S Datasheet v10a

E2S Datasheet v10a E2S Datasheet 1.2.3 v10a ISmC1 ISminialert The ISmC1 is a compact combined 100dB(A) alarm sounder and L.E.D. beacon only one Zener barrier or galvanic isolator required to run both sounder & beacon or

More information

Annubar Flowmeter Series

Annubar Flowmeter Series Reference Manual Appendix B Approvals Annubar Flowmeter Series Hazardous Locations Installations.................. page B-1 Rosemount 3051SFA Product Certifications.......... page B-1 Rosemount 3095MFA

More information

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM Key Features & Benefits: ATEX, UL and CSA Approvals Withstands EN/IEC 60079-0 impact test Enhanced H 2 S and silicone poison resistance 4P-90 CiTipeL Combustible Gas Sensor Part Number: PM143-000 Performance

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

Tank Gauging System Special Safety Instruction

Tank Gauging System Special Safety Instruction Tank Gauging System www.rosemount-tg.com Rosemount TankRadar REX Table of Contents Contents SPECIAL SAFETY INSTRUCTION........................ 1-1 1. GENERAL REQUIREMENTS....................... 1-2 1.1

More information

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter PD685 Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter Actual Size Digits C US Intrinsically Safe 3½ Digits LARGE DISPLAY NEMA 4, Type 4X, IP67 Loop-Powered Field-Mount Process Meter 4-20 ma

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 5 mm flush Usable up to SIL2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching element

More information

Understanding Hazardous Locations Concepts

Understanding Hazardous Locations Concepts Gas Well Deliquification Workshop Sheraton Hotel, February 23 26, 2014 Understanding Hazardous Locations Concepts Mark Scantlebury, P. Eng., BASc President and CEO Extreme Telematics Corp. Disclaimer The

More information

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C PSD1001C INSTRUCTION MANUAL SIL 3 SIL 2 IIB Group Power Supply for Hazardous Area Equipment DINRail Model PSD1001C PSD1001C SIL 3 SIL 2 IIB Group Power Supply for hazardous Area Equipment ISM006510 General

More information

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm 0102 Model Number Features 8 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses. General information 1 Marking of the degree of protection 2 SITRANS T SITRANS T Explosion protected temperature sensor Operating Instructions Range of uses 3 Installation 4 Assembly and disassembly 5 Commissioning

More information

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations INSTRUCTION MANUAL E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING

More information

EU DECLARATION OF CONFORMITY

EU DECLARATION OF CONFORMITY The Low Voltage Directive (LVD) 2014/35/EU and Electromagnetic Compatibility (EMC) Directive 2014/30/EU. Capacitive level sensor DLS 27N(T) Capacitive level sensor type DLS 27N(T) is designed to bistable

More information

standards: standards:

standards: standards: INSTRUCTION MANUAL D2xB1LD2 LED Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING HAZARD

More information

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories Hazardous Locations: Understanding the Basics of Global Compliance Requirements Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories DISCLAIMER/ TERMS OF USE: THE INFORMATION

More information

CONTROL BE MADE CHANGES MAY NOT. Page 1

CONTROL BE MADE CHANGES MAY NOT. Page 1 HI 6020IT and HI 6020JB US & Canada Hazardous Locations User Guide (Class I, II, III, Division 1, Class I, Zone 0 and Zone 20) Hardy Process Solutions Document Number: : 0596-0352-01 REV A CONTROL LLED

More information

Field Certification Certificate of Compliance

Field Certification Certificate of Compliance 2 Field Certification Certificate of Compliance Certificate: 2415870 Master Contract: 225996 Project: 2415870 Issued to: SpectraSensors, Inc. 11027 Arrow Route Rancho Cucamonga, CA 91730 USA Attention:

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2613175 Master Contract: 162874 Project: 2613175 Date Issued: April 18, 2013 Issued to: Fujitsu Technology Solutions GmbH Product Compliance Center Buergermeister-Ulrich-Str

More information

Intrinsically Safe Transmitters, Option Code 2n

Intrinsically Safe Transmitters, Option Code 2n Installation Manual for Intrinsically Safe Transmitters, Option Code 2n ATEX PERSONAL INJURY WARNING DO NOT USE these products as safety or emergency stop devices or in any other application where failure

More information

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS Hazardous Areas - EXPLOSIONPROOF SOLENOIDS SOME HISTORY The classification of hazardous areas into zones established the level of protection required for electrical equipment installed in explosive gas

More information

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations INSTRUCTION MANUAL D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations synchronization requirements of UL1971 & UL1638 / CAN/ULCS526. 2.2 NEC & CEC Class / Division Ratings for US / Canada

More information

UL HAZARDOUS LOCATIONS SERVICES

UL HAZARDOUS LOCATIONS SERVICES UL HAZARDOUS LOCATIONS SERVICES The international preference in hazardous locations certification for over 100 years ul.com/hazloc Explosive Gas Atmospheres Class I Division S Includes flammable gases,

More information

Guide for hazardous areas

Guide for hazardous areas Guide for hazardous areas 1 Hazardous areas definitions 2 Gas and dust s 3 Temperature classifications 4 Common flammable gases, vapours and dust types 5 Protection concepts ATEX and IECEx 6 Protection

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70000287 (085005_0_000) Issued to: steute Schaltgeräte GmbH & Co. KG Brueckenstrasse 91 Loehne, 32584 GERMANY Attention: Patrick Keilwerth The products listed below

More information

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

Rosemount 752 FOUNDATION Fieldbus Remote Indicator Rosemount 752 FOUNDATION Fieldbus Remote Indicator Product Data Sheet 00813-0100-4377, Rev FA Two-wire segment powered device Displays up to eight values Link Master Capability Optional PID, Characterizer,

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity Page 1 of 10 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate

More information

File E Project 97SC January 21, 1998 REPORT

File E Project 97SC January 21, 1998 REPORT File E135803 Project 97SC15289 January 21, 1998 REPORT ON COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT Condor DC Power Supplies Inc. Oxnord, CA

More information

D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410

D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410 FIELDBUS INTRINSICALLY SAFE CONCEPT (FISCO) APPROVAL FISCO allows interconnection of intrinsically safe apparatus to associated apparatus not specially examined in such combination. The criteria for interconnection

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-i Edition 09/2018 CONTENTS 1 Safety instructions 3 1.1 General notes... 3 1.2 EU conformity... 3 1.3 Approval according to the IECEx scheme...

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-nA Edition 08/207 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output

More information

Supplementary Installation and Operating Instructions. Category II2G

Supplementary Installation and Operating Instructions. Category II2G Supplementary Installation and Operating Instructions Flap-type Flow Meter Category II2G 2 Contents 1. General safety directions...3 2. Main safety-relevant characteristics...4 2.1. Category / Zone...4

More information

Rosemount 3900/3900VP

Rosemount 3900/3900VP Rosemount 3900/3900VP General Purpose ph/orp Sensor Instruction Manual LIQ-MAN-3900 Rev. G April 2017 hasgkas Essential Instructions Read this page before proceeding! Emerson designs, manufactures, and

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators EC-Type Examination Certificate TÜV99 ATEX 1479X Accessories BT32 BT32XS BT32XAS BT33 BT34 V1-G-N4-5M-PUR Female cordset, M12, 4-pin, NAMUR,

More information

AND INSTALLATION MANUAL

AND INSTALLATION MANUAL Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel. +358 29 006 260 Fax +358 29 006 1260 Internet: www.labkotec.fi 10.10.2013 SET/DM3AL Level sensor OPERATION AND INSTALLATION MANUAL 1(5) SYMBOLS

More information

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017 Rosemount 214C Sensor 00825-0400-2654, Rev AF NOTICE This guide provides basic guidelines for Rosemount 214C Sensor models. If the sensor was ordered assembled to a temperature thermowell or transmitter,

More information

Operating Instructions Edition 02/2007

Operating Instructions Edition 02/2007 Operating Instructions Edition 02/2007 Temperature Transmitter 7NG3214 with PROFIBUS PA 7NG3215 with FOUNDATION Fieldbus sitrans Introduction 1 General safety notes 2 SITRANS T Temperature transmitter

More information

DB5 Intrinsically Safe Sounder Type DB-5

DB5 Intrinsically Safe Sounder Type DB-5 Operating Instructions RTK Instruments Limited DB5 Intrinsically Safe Sounder Type DB-5 Description The DB5 Sounder is a strong, lightweight warning sounder, CENELEC certified to Ex II 1G EExia IIC T4

More information

OPTIBAR P 1010/2010 C Supplementary instructions

OPTIBAR P 1010/2010 C Supplementary instructions OPTIBAR P 1010/2010 C Supplementary instructions Pressure transmitter Equipment category II 1G / Ga, II 1D / Da in protection type intrinsic safety Exi KROHNE CONTENTS OPTIBAR P 1010/2010 C 1 Safety instructions

More information

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical

More information

Overview of Hazardous Locations as They Relate to Solenoid Valves

Overview of Hazardous Locations as They Relate to Solenoid Valves Overview of Hazardous Locations as They Relate to Solenoid Valves Defined: Hazardous Location - "where fire or explosion hazards may exist due to flammable gases or vapors, flammable liquids, combustible

More information

Intrinsically Safe Solutions

Intrinsically Safe Solutions Intrinsically Safe Solutions INSTALLATION MANUAL 04/12/14 Rev D DOC-01-029 Documentation Feedback Your feedback helps us keep our documentation up to date and accurate. If you have any comments or suggestions

More information

SmartLine. RMA803 SmartLine Remote Fieldbus Indicator Specification 34-ST-03-90, December Technical Information.

SmartLine. RMA803 SmartLine Remote Fieldbus Indicator Specification 34-ST-03-90, December Technical Information. SmartLine Technical Information RMA803 SmartLine Remote Fieldbus Indicator Specification 34-ST-03-90, December 2015 Introduction The Honeywell RMA803 is a Foundation Fieldbus remote indicator suitable

More information

Rosemount 3200HP. ph Sensors. Instruction Manual LIQ-MAN-3200HP Rev. G April 2017

Rosemount 3200HP. ph Sensors. Instruction Manual LIQ-MAN-3200HP Rev. G April 2017 Rosemount 3200HP ph Sensors Instruction Manual LIQ-MAN-3200HP Rev. G April 2017 hasgkas Essential Instructions Read this page before proceeding! Emerson designs, manufactures and tests its products to

More information

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC Quick Introduction to TÛV Denmark TÜV Denmark - is a part of the TÜV NORD Group a global Organisation f Certification and Inspection of: Quality Management Systems, Products, Processes and Qualification

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 15 mm Installation non-flush Assured operating distance s a 0...

More information

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor Labkotec UK Ltd Adminicle House 1 Lumb Lane Audenshaw Manchester M34 5WH GREAT BRITAIN Tel: 0844 3350 477 Fax: 0161 4281 179 E-mail: info@labkotec.co.uk 10.8.2012 Internet: www.labkotec.co.uk 1/13 OilSET-1000

More information