RAE Systems Systems. User Presentation. October Protection Through Detection

Size: px
Start display at page:

Download "RAE Systems Systems. User Presentation. October Protection Through Detection"

Transcription

1 RAE Systems Systems AreaRAE Inert User Presentation October

2 AGENDA Overview & Features Basic Operation Turning the AreaRAE Inert monitor ON Warnings NORMAL & INERT Mode Displays Fault Alarms Daily Procedures Gas Alarms User Modes

3 Overview AreaRAE Inert can operate in two modes Standard AreaRAE (NORMAL Mode) AreaRAE Inert (INERT Mode) Specifically designed for use in low-oxygen (inert) environments Three major differences from the NORMAL mode LEL sensor is disabled PID sensor readings converted to % LEL Octane equivalents default Custom default sensor alarm settings

4 AreaRAE Inert Monitor Features 5 internal sensors Photoionization Detector (PID) O 2, LEL 2 Toxics Optional GPS Built-In MHz RAELink modem Frequency hopping, spread spectrum Up to 2 miles / 3.2 kilometers

5 AreaRAE Inert Monitor Sensors Oxygen: 0-30% Combustibles: 0-100% of LEL Disabled in INERT mode Toxic sensors: CO, H 2 S, SO 2, NO, NO 2, Cl 2, HCN, NH 3, PH 3, HF, HCl VOC monitor: PPM in NORMAL mode 0.1%-19.9% LEL in INERT mode - (0.02%) resolution

6 AreaRAE Inert Monitor Features Large LED display and alarm light Loud 110dB buzzer (10cm) can be muted Strong 500 cc/min Sampling pump 4-Way power Li-Ion rechargeable battery Alkaline battery 120 / 240 VAC 12 VDC Intrinsically safe Class I, Division II, Groups A, B, C, D

7 AreaRAE Inert Monitor Features Long Run time: 18 hrs w/li-ion, 9 hrs with Alkaline *Continuous operation via AC power Rugged Housing: IP53 for water and dust resistant Withstands 1 meter drop Size: 9.25" L x 5.0" W x 9.25" D Weight: 8.5 lb. with battery pack Temperature Range -4oF to 113oF -20oC to 45oC *If the application hazardous area certification regulations allow it, the detector can run continuously using AC power

8 AreaRAE Inert Monitor Pump Makes remote sampling easy Sample draw up to 100 feet! Always use external filter for added protection Pump stall feature: When moisture is detected or when pump is blocked the pump will shut off ~300cc/min at Low flow, ~550cc/min at High flow Only use Teflon tubing

9 AreaRAE Inert Start-up: Turning On Hold MODE Key to turn on (alarm will beep once) Watch display screen for messages such as: Sensors installed & their warranty expiration Alarm limits Last calibration date User/Alarm/Datalog modes *Warm-up will take approximately 90 seconds

10 AreaRAE Inert Start-up: Warnings TOX1 VOC TOX2 Incorrect Year LEL Check Clock!!! OXY If this screen appears during the start-up just acknowledge it with the Y key and follow the procedure for setting the clock. The battery has gone dead and the AreaRAE has detected a mismatch between the date code on the sensors and its internal clock.

11 AreaRAE Inert Start-up: Warnings TOX1 VOC TOX2 O2 Installed LEL Warranty Expired OXY This is a warning screen. As long as the sensor calibrates properly it is valid to continue using it. Acknowledge by pressing the Y key to continue warm-up. For maximum AreaRAE availability, RAE Systems recommends replacing sensors at the end of their warranty period

12 Start-up NORMAL Mode After 90 seconds warm-up, the AreaRAE should display all sensors installed If there is no alarm, and the sensor readings are in the range shown above, then the AreaRAE is ready for use

13 Start-up INERT Mode If the detector was shut off in INERT mode, the unit will start up in INERT mode LEL display is replaced with INRT CO display is replaced with COH2 VOC display changed from ppm to %LEL Resolution of 3 decimal places instead of 1 NOTE: When the AreaRAE Inert is turned on while in INERT mode, and its alarm is sounding, it is likely that the normal oxygen level of 20.9% in fresh air is causing this.

14 Switching Operation Modes Menu options allow switching between NORMAL & INERT mode -Press MODE to scroll through menu options NOTE: Unit will always start up in the mode it was in when shut down

15 Wireless Mode Display A small radio antenna displayed in the left center of the AreaRAE screen indicates that the wireless link is established

16 GPS Mode Display A small satellite displayed in the left center of the AreaRAE screen indicates that the GPS is communicating. A minimum of 3 satellites is needed for good signal The display will show a max of 4 satellites GPS on but no satellite signal =

17 Datalog Mode Display A small L is displayed in the left center of the AreaRAE screen indicates datalogging Will datalog 20,000 points (64 hrs, 5 channels, 1 min interval) User can choose one of 4 datalog modes (Manual, Automatic, Periodic & Scheduled in ProRAE Suite)

18 AreaRAE Inert Start-up: Lamp Alarm Lamp display along with audible alarm indicates that PID lamp has failed to light Press Y/+ key to clear alarm, if it clears AreaRAE is ready for use If alarm does not clear, wait a few minutes and check again

19 AreaRAE Inert Start-up: Lamp Alarm If after a few minutes the Lamp message remains, turn off AreaRAE and restart If after restart Lamp message disappears, AreaRAE is ready for use If after restart Lamp message remains, the PID Lamp needs service

20 AreaRAE Alarms: Pump Pump display along with 3 beep audible alarm indicates that pump has stopped due to line clog Pump alarm is a latching alarm Clear line/filter and press Y/+ key to clear alarm and restart pump

21 AreaRAE Alarms: Low Battery A flashing Bat display along with a 1 beep alarm every 10 seconds indicates that the battery voltage has dropped below 6.2 V and it will shut down in minutes Quickly complete confined space entry and charge AreaRAE or install alkaline battery

22 AreaRAE Inert Start-up: Pump Check Every time the AreaRAE Inert is used it is important to check pump flow: Block the filter on the pump inlet Reset pump alarm by pressing the Y key If pump does not go into alarm, check for loose/cracked filter or service pump

23 AreaRAE Inert Start-up: Bump Test Periodic functional testing of the sensors by doing a bump test is recommended Defined as a brief exposure of the monitor to the calibration gas and the sensors to show response and trigger the lowest alarm set point for each sensor The monitor should be calibrated if it does not pass a bump test, but no less than every 6 months, depending on use and exposure to gas and contamination Always operate monitor with external filter It is recommended to keep the units on charge when not in use

24 AreaRAE Inert Alarm Signals The AreaRAE will provide audible and visual alarms to alert users to unsafe states It is extremely important to note that during the following conditions the alarm signals are disabled: When entering the Communicate with PC? standby mode. When entering the Calibrate Monitor menu When viewing data in the View or Change Datalog? menu

25 AreaRAE Inert Alarms: High AreaRAE Inert unit operating in NORMAL mode with VOC High Alarm of 102 ppm High display along with 3 beat/second audible/visible alarm and flashing display backlight indicates that the high alarm has exceeded VOC sensor (PID) has high alarm setpoint of 100 ppm default in Normal mode Press Y/+ key to clear if latching alarm

26 AreaRAE Inert Alarms: Low Low display along with 2 beat/second audible/visual alarm and flashing display backlight indicates that Oxygen sensor has gone into low alarm All other sensors, Low alarm indicates the first warning Press Y/+ key to clear if latching alarm

27 AreaRAE Alarms: STEL & TWA Short Term Exposure Limit (STEL) & Time Weighted Average (TWA) alarms are available for toxic sensors and for PID in NORMAL operation mode If either alarm is exceeded, STEL or TWA is indicated for sensor in alarm, along with a 1 beat/second audible/visual alarm STEL alarm will only clear after 15 minutes in clean air or the AreaRAE is turned off! TWA alarm will only clear after moving to clean air and then turning off the AreaRAE

28 INERT Mode Alarm Levels LOW HIGH STEL TWA CO 35 ppm 200 ppm 100 ppm 35 ppm H2S 10 ppm 25 ppm 15 ppm 10 ppm LEL NA NA NA NA O2 0.5 % 5 % NA NA PID* 1000 ppm = 10% LEL 1500 ppm = 15% LEL NA NA *Octane equivalents

29 NORMAL Mode Alarm Levels LOW HIGH STEL TWA CO 35 ppm 200 ppm 100 ppm 35 ppm H2S 10 ppm 25 ppm 15 ppm 10 ppm LEL 10 ppm 20 ppm NA NA O % 23.5 % NA NA PID 50 ppm 100 ppm 25 ppm 10 ppm

30 Alarms: LEL OFF When operating AreaRAE Inert in NORMAL mode: OFF display along with a 3 beat/second audible/visual alarm indicates that LEL sensor has been exposed to too much gas and has shut off to protect the sensor. Move the meter to clean air and press the Y key to reset.

31 Alarms: NEG NEG display along with a 1 beat/second audible/visual alarm indicates that a sensor has drifted negative (below zero) because the sensor was zeroed in an area containing gas. Perform Fresh Air Calibration in an area clear of all gases.

32 3 User Modes Normal Mode has different privilege levels or User Modes Program Mode: 11 screens for most advanced users Display Mode: 7 screens and has password to get into programming (default mode) Text Mode: 3 screens and has password to get into programming

33 Comparison of User Modes Program (11) Sensor ID Enter Inert Atmosphere? PEAK MIN STEL TWA Battery Time/Date/Temp Start Datalog* LEL Gas VOC Gas Disable GPS? PC Comm Display (7) Sensor ID Enter Inert Atmosphere? PEAK MIN STEL TWA Battery PC Comm Text (3) Sensor ID w/ok Enter Inert Atmosphere? Battery PC Comm * Will not show if no datalogging option or auto datalogging

34 Instantaneous Reading (Main Display) AreaRAE will return to this screen in 60 seconds if left in any subsequent screen This screen alternates between the instantaneous reading and the sensor name approximately every 3 seconds Tap MODE key to proceed to next screen

35 Switching Operation Modes Allow switching between NORMAL & INERT modes Press Y or N key to enter or skip option Tap MODE key to proceed to next screen NOTE: Unit will always start up in the mode it was in when shut down

36 Peak Reading Display This screen is deleted in Text Mode Holds Highest reading since AreaRAE was turned on Press Y key to clear peak/min Screen will prompt: Are you sure? Press Y to confirm peak clearing Tap MODE key to proceed to next screen

37 Minimum Reading Display This screen is deleted in Text Mode Holds Lowest reading since AreaRAE was turned on Tap MODE key to proceed to next screen

38 STEL Display This screen is deleted in Text Mode Short Term Exposure Limit (average for the past 15 minutes) Displays *** until AreaRAE has been on for 15 minutes STEL only is calculated for VOC (NORMAL mode only) Toxic sensors STEL alarm beeps once a second Tap MODE key to proceed

39 TWA Display This screen is deleted in Text Mode Time Weighted Average is the accumulated reading of gas concentration divided by 8 hours since the AreaRAE was turned on TWA only is calculated for VOC & toxics TWA alarm beeps once per second Tap MODE key to proceed to next screen

40 Battery Voltage Display This screen is deleted in Text Mode AreaRAE shuts down when battery voltage drops below 6.2 volts Normal Full Charge is over 7.6 volts Tap MODE key to proceed to next screen

41 Date/Time/Run Time/Temp. Display This screen is deleted in Display & Text Mode Date, Time of day Accumulated time in hours and minutes since the AreaRAE was turned on Temperature in Centigrade or Fahrenheit (operating range from oC, oF) Tap MODE key to proceed

42 Datalog Mode Display This screen is deleted in Display & Text Mode Manual: logs if Y/+ key is pushed now Automatic: this screen is deleted and it logs data when as soon as the AreaRAE on Scheduled: logs data at a preset time Will datalog 20,000 points (64 hrs of data) Entering programming pauses datalogging NOTE: this datalogging is independent of the data logged on host controller PC

43 LEL Units Display This screen is deleted in Display & Text Mode Target Gas for LEL displayed here (AreaRAE is currently measuring LEL in units of methane) Correction Factor can only be changed in programming mode Tap MODE key to proceed to next screen

44 VOC Units Display This screen is deleted in Display & Text Mode Target Gas VOC is displayed here (AreaRAE is currently measuring VOC in units of isobutylene) Correction Factor can only be changed in programming mode Tap MODE key to proceed to next screen

45 Communicate with PC Display If Y/+ key is pushed then AreaRAE will display Monitor will Pause. OK? If Y/+ key is pushed again the AreaRAE will display Ready... until it receives a signal from the computer or the MODE key is pressed. Tap MODE key to proceed

46 Communicate with PC Display When the AreaRAE is in this communication standby mode it stops monitoring gas concentrations and stops datalogging. Datalogging must be manually restarted when exiting unless automatic datalogging is in use.

47 AreaRAE: Power Off Hold Mode Key for full 5 seconds Audible alarm will beep and display will read Power-down in...5 seconds Plug 15V DC charger into AreaRAE charge port when not in use

Using the QRAE Plus personal multigas monitor

Using the QRAE Plus personal multigas monitor Using the QRAE Plus personal multigas monitor Firmware v 1.10 QRAE Plus The Hazardous Environment Detection Company QRAE Plus features Turning on the QRAE Plus Recommended Daily Start-up Procedure User

More information

Operate the Mutli-Gas Monitor PID

Operate the Mutli-Gas Monitor PID TASK: Operate the Multi-Gas Monitor Learning Objective CONDITION: In a classroom environment, given a fully charged Multi-gas Monitor with the manufacturer operator s manual, all monitor components/accessories,

More information

Using the MiniRAE 2000 & ppbrae PID

Using the MiniRAE 2000 & ppbrae PID MiniRAE 2000 Using the MiniRAE 2000 & ppbrae PID Firmware v. 1.20 (rev C) The Hazardous Environment Detection Company Training Agenda: MiniRAE 2000 & ppbrae features Turning on the MiniRAE 2000 & ppbrae

More information

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility EAGLE 2 Inlet fitting Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility Internal / external hydrophobic filters Self healing polyurethane protective

More information

GasAlertMicroClip X3 Specifications

GasAlertMicroClip X3 Specifications GasAlertMicroClip X3 Specifications The instrument must satisfy the following: Physical Specifications Size (h x w x d) Physical size shall be no larger than 4.4 x 2.4 x 1.2 in. / 11.3 x 6.0 x 3.2 cm Weight

More information

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots 5 Operating Modes GX-6000 Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots GX-6000 5 Operating modes Normal Leak Check Inert Bar hole Snap Log Monitor up to

More information

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots 5 Operating Modes GX-6000 Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots CONFINED SPACE ENTRY Monitor LEL, O2, CO, and H2S Internal sample pump Pull samples

More information

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual ToxiRAE II PGM-1100 Series Personal Toxic Gas Monitor User Manual 045-4003-000, Rev C May 2007 - READ BEFORE OPERATING - This manual must be carefully read by all individuals who have or will have the

More information

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012 Confined Space Monitoring Leak Investigation 1 Functions 4 Bar Hole Sampling Line Purge Testing Actual Size GX-2012 3 Operating Modes Internal sample draw pump with 50 range Low flow alarm 3 bright visual

More information

ALTAIR 5X Multigas Detector Product Specification

ALTAIR 5X Multigas Detector Product Specification ALTAIR 5X Multigas Detector Product Specification PHYSICAL CHARACTERISTICS Gas delivery Size, pumped unit without IR Size, pumped unit with IR Weight Handling Case material Environmental protection Display

More information

Sirius MultiGas Detector

Sirius MultiGas Detector Sirius MultiGas Detector Operating Manual In North America, to contact your nearest stocking location, dial toll-free 1-800-MSA-2222 To contact MSA International, dial 1-412-967-3354 or 1-800-MSA-7777

More information

AreaRAE PGM-5020 WIRELESS MULTI-GAS MONITOR. Operation & Maintenance Manual Document Number: Revision B, April 2003

AreaRAE PGM-5020 WIRELESS MULTI-GAS MONITOR. Operation & Maintenance Manual Document Number: Revision B, April 2003 AreaRAE PGM-5020 WIRELESS MULTI-GAS MONITOR Operation & Maintenance Manual Document Number: 029-4001-000 Revision B, April 2003 This product may be covered by one or more of the following U.S. Patents:

More information

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual ToxiRAE II PGM-1100 Series Personal Toxic Gas Monitor User Manual 045-4003-000, Revision B, March 2005 - READ BEFORE OPERATING - This manual must be carefully read by all individuals who have or will have

More information

For the Safety of Your

For the Safety of Your For the Safety of Your Team in Confined Spaces CSM 5000 Portable Multi-Gas Monitor H 2 S OX CO EX Do it Right Do it Safe Power/Select Button Used for turning the CSM 5000 ON and OFF, accessing download

More information

Instruction Manual Eagle Series

Instruction Manual Eagle Series Instruction Manual Eagle Series Portable Multi-Gas Detector Part Number: 71-0028RK Edition: Third Released: July 2001 RKI Instruments, Inc. 1855 Whipple Rd. Hayward, CA 94544 (510) 441-5656 Warranty RKI

More information

IMR IX176 Portable Gas Detector User Manual

IMR IX176 Portable Gas Detector User Manual IMR Portable Gas Detector User Manual Read this manual carefully before using this device. (727) 328-2818 / (800) RING-IMR Fax: (727) 328-2826 www.imrusa.com Ver. 1.0A4 CONTENTS SERVICE GUIDELINES... 3

More information

GasAlertMicro 5. 1, 2, 3, 4, and 5 Gas Detectors. Quick Reference Guide

GasAlertMicro 5. 1, 2, 3, 4, and 5 Gas Detectors. Quick Reference Guide O 2, CO, H 2 S, PH 3, SO 2, Cl 2, NH 3, NO 2, HCN, ClO 2, O 3, VOC, and Combustibles 1, 2, 3, 4, and 5 Gas Detectors Quick Reference Guide Limited Warranty & Limitation of Liability BW Technologies Ltd.

More information

Dräger X-am approved as type MQG 0010 Multi-Gas Monitor Technical Manual _01.eps

Dräger X-am approved as type MQG 0010 Multi-Gas Monitor Technical Manual _01.eps Dräger X-am 5000 approved as type MQG 0010 Multi-Gas Monitor Technical Manual 04723999_01.eps Content Content For Your Safety..................................................... 4 Safety symbols used

More information

Monitores Personales. Personal Monitor

Monitores Personales. Personal Monitor Monitores Personales Personal Monitor Micro IV Full Featured Personal Monitor Micro IV Single-gas Detector Highly configurable smart sensor design Wide range of sensors including O 2, H 2 S, CO, NH 3,

More information

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

MultiRAE Lite. Wireless Portable Multi-Gas Monitor MultiRAE Lite Wireless Portable Multi-Gas Monitor The MultiRAE Lite is an optimal one-to-six 4 -gas monitoring solution for personal protection (including confined space entry) and multi-gas leak detection

More information

GasAlertMicro 5 and GasAlertMicro 5 PID O 2, CO, H 2 S, PH 3, SO 2, Cl 2, NH 3, NO 2, HCN, ClO 2, O 3, VOC, and Combustibles

GasAlertMicro 5 and GasAlertMicro 5 PID O 2, CO, H 2 S, PH 3, SO 2, Cl 2, NH 3, NO 2, HCN, ClO 2, O 3, VOC, and Combustibles GasAlertMicro 5 and GasAlertMicro 5 PID O 2, CO, H 2 S, PH 3, SO 2, Cl 2, NH 3, NO 2, HCN, ClO 2, O 3, VOC, and Combustibles 1, 2, 3, 4, and 5 Gas Detectors Quick Reference Guide Limited Warranty & Limitation

More information

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector. Introduction United Safety applies the detection system as a multi-point monitoring for toxic gases, combustibles and oxygen hazards. Self-powered and solar-capable, the features unequaled versatility,

More information

ALTAIR 5X Multigas Detector

ALTAIR 5X Multigas Detector ALTAIR 5X Multigas Detector With MSA XCell Sensor Technology IT S WHAT S INSIDE THAT COUNTS Now with advanced PID for VOC detection Because every life has a purpose... Save Time, Save Money, Save Lives

More information

E1000 Portable gas detector

E1000 Portable gas detector E1000 Portable gas detector Operation manual Ver:HWWM161229CG Read this manual carefully before using the device Table of Contents SAFETY INFORMATION... - 1-1. BRIEF INTRODUCTION... - 3-2. MAIN FUNCTION

More information

ALTAIR 5X Multigas Detector

ALTAIR 5X Multigas Detector ALTAIR 5X Multigas Detector With MSA XCell Sensor Technology IT S WHAT S INSIDE THAT COUNTS Now with advanced PID for VOC Detection Because every life has a purpose IT S WHAT S INSIDE THAT COUNTS WORKERS

More information

RAE Systems. Using the MeshGuard. Protection Through Detection

RAE Systems. Using the MeshGuard. Protection Through Detection RAE Systems Using the MeshGuard Protection Through Detection Turning on the MeshGuard Hold down the [M] key and release it when the MeshGuard beeps. The MeshGuard performs a selftest, followed by warm-up

More information

DI220 Using the Optional Docking Station The maintenance and operating functions of the Micro IV can be automated with the Micro IV Docking Station.

DI220 Using the Optional Docking Station The maintenance and operating functions of the Micro IV can be automated with the Micro IV Docking Station. DI220 Using the Optional Docking Station The maintenance and operating functions of the Micro IV can be automated with the Micro IV Docking Station. The following steps outline the correct sequence to

More information

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08 Beacon 200 Gas Monitor Operator s Manual Part Number: 71-2102RK Released: 6/6/08 Table of Contents Chapter 1: Introduction.................................................3 Overview.............................................................3

More information

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING II 2 G Ex ib IIB T3 IP20 PENDING (USA) Class 1, Division 1, Groups C and D, T3 Suitable for

More information

MultiRAE Plus. PGM-50/4, PGM-50/4P, PGM-50/5P Multiple-Gas Monitor

MultiRAE Plus. PGM-50/4, PGM-50/4P, PGM-50/5P Multiple-Gas Monitor MultiRAE Plus PGM-50/4, PGM-50/4P, PGM-50/5P Multiple-Gas Monitor User Manual 008-4022-000, Revision B, November 2003 Equipment List Number Part Part Number Monitor Only (not shown)* Shipping case 008-3040-000

More information

Portable type of Carbon Dioxide Detector Model: GT220

Portable type of Carbon Dioxide Detector Model: GT220 Specifications (Specification maybe changed without notice) Model Type Sensor Target Sampling method Measuring range Resolution/accuracy / sampling time Alarm level Audible alarm / Alarm message Backlight

More information

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling NATURAL GAS DETECTOR Confined Space Monitor Leak Investigation Line Purge Testing Bar Hole Sampling CONFINED SPACE ENTRY Monitor LEL, O2, CO, and H2S Smallest 5 sensor sample draw instrument Internal sample

More information

(Vendor Signature) By Mail: Mark sealed proposal with Bid/Proposal No.2014'33' Vendor Contact I nformation :

(Vendor Signature) By Mail: Mark sealed proposal with Bid/Proposal No.2014'33' Vendor Contact I nformation : Vendor Contact I nformation : By Mail: (Vendor Signature) Police Depaftment - Radiation/Chemical Detection Device (Please see attached specifications) Proposals are to be submitted sealed with Bid/Proposal

More information

PHD6. Flexible, comprehensive monitoring backed up by high performance functionality

PHD6. Flexible, comprehensive monitoring backed up by high performance functionality PHD6 Flexible, comprehensive monitoring backed up by high performance functionality PHD6 TM Flexible solution that adapts to meet needs Five sensor slots offering up to six channels of detection Sixteen

More information

1.1 Definitions of alert icons. For your safety

1.1 Definitions of alert icons. For your safety For your safety 1 For your safety Before using this product, carefully read these Instructions for Use and those of the associated products. Strictly follow the Instructions for Use. The user must fully

More information

X5 Personal Gas Detector. Operating Manual

X5 Personal Gas Detector. Operating Manual X5 Personal Gas Detector X5 Operating Manual Limited Warranty and Limitation of Liability All products are designed and manufactured to the latest internationally recognized standards by Honeywell Analytics

More information

Issue 4 10/10/11. Part Number: 48160

Issue 4 10/10/11. Part Number: 48160 User Handbook SHIPSURVEYOR USER HANDBOOK Issue 4 10/10/11 Part Number: 48160 GMI welcomes comments on all our publications. Your comments can be of great value in helping us to improve our customer publications.

More information

1, 2, 3, and 4-Gas Detector. Technical Reference Guide

1, 2, 3, and 4-Gas Detector. Technical Reference Guide 1, 2, 3, and 4-Gas Detector Technical Reference Guide Limited Warranty and Limitation Liability BW Technologies LP (BW) warrants the product to be free from defects in material and workmanship under normal

More information

Dräger X-am approved as type MQG 01** Multi-Gas Monitor. Technical Handbook. CO2 Vol% CH4 %UEG. CO ppm. ppm NH _01.

Dräger X-am approved as type MQG 01** Multi-Gas Monitor. Technical Handbook. CO2 Vol% CH4 %UEG. CO ppm. ppm NH _01. Dräger X-am 5600 approved as type MQG 01** Multi-Gas Monitor Technical Handbook CO2 CH4 %UEG O2 CO H2S NH3 04733072_01.eps Content Content For Your Safety......................................................4

More information

IMR EX610. Portable Gas Detector. Operation Manual

IMR EX610. Portable Gas Detector. Operation Manual IMR EX610 Portable Gas Detector Operation Manual IMR Environmental Equipment, Inc. 3634 Central Ave. St. Petersburg, FL 33711 Phone: 727-328-2818 email: info@imrusa.com Read this manual carefully before

More information

Model GX Operator s Manual

Model GX Operator s Manual Model GX-2012 Operator s Manual WARNING Read and understand this instruction manual before operating instrument. Improper use of the gas monitor could result in bodily harm or death. Periodic calibration

More information

SAFESITE Multi-Threat Detection System

SAFESITE Multi-Threat Detection System SAFESITE Multi-Threat Detection System The SAFESITE Multi-Threat Detection System simultaneously monitors and wirelessly communicates six potential threats: CWAs, VOCs, TICs, gamma radiation, combustible

More information

NH3 RESPONDER PORTABLE AMMONIA LEAK DETECTOR. Quick Reference Guide

NH3 RESPONDER PORTABLE AMMONIA LEAK DETECTOR. Quick Reference Guide NH3 RESPONDER PORTABLE AMMONIA LEAK DETECTOR Quick Reference Guide 2 NH3 RESPONDER Specially configured GasAlertMicro 5 from Refer to Operating Manual for more details. Manual provided on CD with unit

More information

Safe Operation Manual. Honeywell IQ Force Gas Detector

Safe Operation Manual. Honeywell IQ Force Gas Detector Safe Operation Manual Honeywell IQ Force Gas Detector Honeywell Analytics 800-663-4164 403-248-9226 Fax 403-575-3708 03JUN2012 P/N 50105843-047 Version 01 http://www.honeywell.com HONEYWELL IQ Force PERSONAL

More information

Bacharach Bodyguard 4 User's Guide

Bacharach Bodyguard 4 User's Guide Bacharach Bodyguard 4 User's Guide This manual and the software described in it are copyrighted, with all rights reserved. Under the copyright laws, this manual or the software may not be copied, in whole

More information

UltraRAE 3000 Basic Operation Pocket Reference

UltraRAE 3000 Basic Operation Pocket Reference UltraRAE 3000 Basic Operation Pocket Reference PN: 059-4025-000 Rev. A May 2008 Read Before Operating This Pocket Reference is intended as a quick guide to basic use and calibration of your instrument.

More information

CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE

CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE GasAlertMicro 5 IR from Refer to for more details. Manual provided on CD with unit at time of purchase 2 Table of Contents Getting Started.

More information

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual MODEL: SP12C7 (Portable 4 gas detector) Operating Manual Guarantee and Repair Senko Co., Ltd. guarantees the products of SP series for 24 months from the shipping date and repairs or replaces the defected

More information

INSTRUCTION MANUAL MODEL GX-82A

INSTRUCTION MANUAL MODEL GX-82A INSTRUCTION MANUAL MODEL GX-82A PORTABLE THREE GAS DETECTOR RKI Instruments, Inc. 1855 Whipple Road Hayward, CA 94544 Tel: 510-441-5656 Table of Contents INTRODUCTION 1 DESCRIPTION 2 COMPONENTS AND CONTROLS

More information

NH 3 RESPONDER Portable Ammonia Leak Detector QUICK REFERENCE GUIDE

NH 3 RESPONDER Portable Ammonia Leak Detector QUICK REFERENCE GUIDE Portable Ammonia Leak Detector QUICK REFERENCE GUIDE Specially configured GasAlert Micro 5 PID from Refer to for more details. Manual provided on CD with unit at time of purchase 2 Table of Contents Getting

More information

User Manual. Single Gas Detector

User Manual. Single Gas Detector Single Gas Detector Limited Warranty and Limitation Liability BW Technologies LP (BW) warrants the product to be free from defects in material and workmanship under normal use and service for a period

More information

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction BST-MG08/09 Multi-gas Detecting Alarm Manual Instruction 1. Application: This product is designed to ensure safety for users who work in dangerous places. It s used for detecting CO, O2, H2S, CH4 simultaneously

More information

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219) WARRANTY AND REPAIR POLICY Your SENSIT HXG-2d instrument is warranted to be free from defects in materials and workmanship for a period of two years after purchase (excluding sensor, calibration and batteries).

More information

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20 SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex II3G Ex ic llb T3 IP20 PENDING (USA) Class 1, Zone 2, AEx nl llb T3 PENDING (Canada) Class

More information

GasAlertMicro 5 / PID / IR

GasAlertMicro 5 / PID / IR GasAlertMicro 5 / PID / IR O 2, CO, H 2 S, PH 3, SO 2, Cl 2, NH 3, NO 2, HCN, ClO 2, O 3, VOC, CO 2 and Combustibles 1, 2, 3, 4, and 5 Gas Detectors User Manual Limited Warranty & Limitation of Liability

More information

G460. Multi-gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

G460. Multi-gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734) G460 Multi-gas Detector Operations Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.gfg-inc.com GfG Products for Increased Safety Congratulations on your purchase

More information

MiniRAE 3000 ppbrae Basic Operation Pocket Reference

MiniRAE 3000 ppbrae Basic Operation Pocket Reference MiniRAE 3000 ppbrae 3000 Basic Operation Pocket Reference PN: 059-4030-000-D Rev. B August 2010 Read Before Operating This Pocket Reference is intended as a quick guide to basic use and calibration of

More information

Model GX-2003 Operator s Manual

Model GX-2003 Operator s Manual Model GX-2003 Operator s Manual Part Number: 71-0089RK Revision: D Released: 3/26/07 www.rkiinstruments.com Warranty RKI Instruments, Inc., warrants the Model GX-2003 sold by us to be free from defects

More information

Using the GammaRAE II Responder Personal Radiation Detector and Dosimeter in One. Firmware Version 3.00 D August 2006

Using the GammaRAE II Responder Personal Radiation Detector and Dosimeter in One. Firmware Version 3.00 D August 2006 Using the GammaRAE II Responder Personal Radiation Detector and Dosimeter in One Firmware Version 3.00 D August 2006 GammaRAE II Responder Features Getting Started Replacing the batteries Turn the unit

More information

QUICK REFERENCE GUIDE

QUICK REFERENCE GUIDE - 4GAS RESPONDER Confined Space Entry Portable Gas Detector QUICK REFERENCE GUIDE 4-GAS RESPONDER GasAlertMicro 5 from Refer to for more details. Manual provided on CD with unit at time of purchase 2 Table

More information

MeshGuard TM Monitor User s Guide

MeshGuard TM Monitor User s Guide MeshGuard TM Monitor User s Guide Rev. J May 2018 P/N D01-4002-000 Copyright 2018 RAE Systems by Honeywell. Contents 1 Standard Kit... 6 2 General Information... 6 3 Physical Description... 8 3.1 LCD Display...

More information

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual MODEL: SP12C7 (Portable 4 gas detector) Operating Manual Guarantee and Repair Senko Co., Ltd. guarantees the products of SP series for 24 months from the shipping date and repairs or replaces the defected

More information

GX-2009 Portable Gas Monitor Operator s Manual

GX-2009 Portable Gas Monitor Operator s Manual GX-2009 Portable Gas Monitor Operator s Manual Part Number: 71-0158RK Revision: P2 Released: 11/12/08 www.rkiinstruments.com Warranty RKI Instruments, Inc., warrants the GX-2009 sold by us to be free from

More information

Polytector III G999 for Ex zone 0

Polytector III G999 for Ex zone 0 Polytector III G999 for Ex zone 0 7 Sensor Personal Gas Monitor with smart pump, remote multiple instrument monitoring, two way communication and Man Down options Record-breaking The G999 is the world

More information

Reference Manual. MultiPro Gas Detector

Reference Manual. MultiPro Gas Detector Reference Manual MultiPro Gas Detector Honeywell Analytics, Inc. 405 Barclay Blvd Lincolnshire, IL 60069 (800) 711-6776 (847) 955-8200 Fax (800) 995 4992 27August 2012 P/N 13-278 Version 3 www.honeywellanalytics.com

More information

Reference Manual MultiPro Gas Detector

Reference Manual MultiPro Gas Detector Reference Manual MultiPro Gas Detector GasTech Australia Pty Ltd 24 Baretta Rd Wangara Western Australia 6065 Tel 1800 999 902 Fax 1800 999 903 http://www.gastech.com.au 1 MULTIPRO PERSONAL PORTABLE GAS

More information

Micro IV Operation Manual

Micro IV Operation Manual Micro IV Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS Page Introduction...4 For Your Safety...4 Application and Use...4 General Description...4 Detection Principle...5

More information

1, 2, 3, and 4-Gas Detector. Technical Reference Guide

1, 2, 3, and 4-Gas Detector. Technical Reference Guide 1, 2, 3, and 4-Gas Detector Limited Warranty and Limitation Liability BW Technologies LP (BW) warrants the product to be free from defects in material and workmanship under normal use and service for a

More information

Technical Reference Guide. 1, 2, 3, and 4-Gas Detector

Technical Reference Guide. 1, 2, 3, and 4-Gas Detector Technical Reference Guide 1, 2, 3, and 4-Gas Detector Introduction 1 Zeroing the Sensors 1 Contacting BW Technologies by Honeywell 2 Safety Information - Read First 2 Sensor Poisons and Contaminants 5

More information

Personal Single Gas Monitor. Activation Operation Troubleshooting

Personal Single Gas Monitor. Activation Operation Troubleshooting Personal Single Gas Monitor Activation Operation Troubleshooting Part Number: 17123100 Revision: 3.0 Release Date: January 1, 2009 Table of Contents Warnings and Cautionary Statements... 3 Hardware Overview...

More information

Microtector II G gas-detector with performance test approval. Worldwide Supplier Of Gas Detection Solutions

Microtector II G gas-detector with performance test approval. Worldwide Supplier Of Gas Detection Solutions Microtector II G460 7-gas-detector with performance test approval Performance test approved multi-gas detector (290g) Extremely loud alarm, 103 db(a) for optimum personnel protection Full featured, rugged

More information

Operating Instructions and Maintenance Manual

Operating Instructions and Maintenance Manual Impact Series Operating Instructions and Maintenance Manual 4.9.4 Enforcer Calibration This is designed for oxygen, flammable (catalytic or IR LEL sensor), carbon monoxide and hydrogen sulfide, using a

More information

BM25 and BM25 Wireless

BM25 and BM25 Wireless BM25 and BM25 Wireless Class Modules Module 1 BM25 Features and Benefits Unit Specification Sensor Configuration Features and Benefits Module 2 Wireless Option Module 3 BM25 Operations External Features

More information

MiniRAE 3000 User s Guide

MiniRAE 3000 User s Guide MiniRAE 3000 User s Guide Rev. C August 2010 P/N 059-4020-000 FCC Information Contains FCC ID: PI4411B The enclosed device complies with part 15 of the FCC rules. Operation is subject to the following

More information

MSA Portable Gas Detection

MSA Portable Gas Detection Because every life has a purpose MSA Portable Gas Detection Marine Chemist Association Seminar 2015 Paul Jung Product Line Manager Portable Instruments Our Mission & Vision Mission to see to it that men

More information

Operator s Manual. 1, 2, 3, and 4-Gas Detector

Operator s Manual. 1, 2, 3, and 4-Gas Detector Operator s Manual 1, 2, 3, and 4-Gas Detector Limited Warranty and Limitation Liability BW Technologies LP (BW) warrants the product to be free from defects in material and workmanship under normal use

More information

MiniRAE 3000 User s Guide

MiniRAE 3000 User s Guide MiniRAE 3000 User s Guide Rev. A April 2007 P/N 059-4020-000 Copyright 2007 RAE Systems, Inc. Contents Read Before Operating... 4 Special Notes... 5 Warnings... 6 Standard Contents... 8 General Information...

More information

GX-2009 Portable Gas Monitor Operator s Manual

GX-2009 Portable Gas Monitor Operator s Manual GX-2009 Portable Gas Monitor Operator s Manual Part Number: 71-0158RK Revision: F Released: 5/29/13 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating instrument.

More information

ToxiRAE Pro PID User s Guide

ToxiRAE Pro PID User s Guide ToxiRAE Pro PID User s Guide P/N G02-4008-000 Rev. C March 2013 Copyright 2013 RAE Systems, Inc. Contents Read Before Operating... 3 1. General Information... 6 2. Specifications... 7 3. Overview... 8

More information

INNOVA Series INSTRUCTION MANUAL P/N REV. D

INNOVA Series INSTRUCTION MANUAL P/N REV. D INNOVA Series INSTRUCTION MANUAL P/N 71-6417 REV. D THERMO ELECTRON CORPORATION ENVIRONMENTAL INSTRUMENTS 27 FORGE PARKWAY FRANKLIN MASSACHUSETTS 02038 (866) 282-0430 Toll Free (508) 520-0430 International

More information

Operating Manual ALTAIR 5X PID. Multigas Detector. Order No.: /00. MSAsafety.com

Operating Manual ALTAIR 5X PID. Multigas Detector. Order No.: /00. MSAsafety.com Operating Manual ALTAIR 5X PID Multigas Detector Order No.: 10165710/00 MSAsafety.com 1000 Cranberry Woods Drive Cranberry Township, PA 16066 A Phone 1-800-MSA-2222 Fax 1-800-967-0398 For your local MSA

More information

Dräger X-am 2500 (MQG 0011) Technical Manual

Dräger X-am 2500 (MQG 0011) Technical Manual Dräger X-am 2500 (MQG 0011) Technical Manual i Content Content 1 For your safety............................4 1.1 General safety statements....................4 1.2 Definitions of alert icons......................4

More information

T.ex Single Gas Detector VISA

T.ex Single Gas Detector VISA T.ex Single Gas Detector The T.ex is newest instrument in the Promat portfolio. The instrument is currently available in Oxygen, Hydrogen Sulphide and Carbon Monoxide versions. A Bump Test Station is available

More information

GX-2009 MSHA Certified Version CH 4 /O 2 /CO/H 2 S Portable Gas Monitor Operator s Manual

GX-2009 MSHA Certified Version CH 4 /O 2 /CO/H 2 S Portable Gas Monitor Operator s Manual GX-2009 MSHA Certified Version CH 4 /O 2 /CO/H 2 S Portable Gas Monitor Operator s Manual Part Number: 71-0325 Revision: F Released: 8/14/18 www.rkiinstruments.com WARNING Read and understand this instruction

More information

MeshGuard LEL User s Guide

MeshGuard LEL User s Guide MeshGuard LEL User s Guide \\\\\ Rev. C August 2014 P/N D01-4014-000 Copyright 2014 RAE Systems by Honeywell. Contents 1 Standard Kit... 6 2 General Information... 6 3 Physical Description... 8 3.1 LCD

More information

Micro III (Models G203, G203S, and G213) Operation Manual

Micro III (Models G203, G203S, and G213) Operation Manual Micro III (Models G03, G03S, and G13) Operation Manual Worldwide Manufacturer of Gas Detection Solutions Table of contents Page Introduction... 3 For your safety... 3 Application and use... 3 General

More information

SENSIT HXG-2d Combustible Gas Detector

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL SENSIT HXG-2d Combustible Gas Detector Read and understand instructions before use. 710183 UL 913 Intrinsically Safe for Use in Class I, Groups C and D, T3 Hazardous Locations For use

More information

GX-2009 Portable Gas Monitor Operator s Manual

GX-2009 Portable Gas Monitor Operator s Manual Leaders in Gas Detection Since 1977 GX-2009 Portable Gas Monitor Operator s Manual Part Number: Revision: Released: R71-0158RK D 17 January 2012 OIL & GAS CONFINED HVAC MINING LABORATORIES COUNCILS DEFENCE

More information

Reference Manual PhD5 Multi Gas Detector

Reference Manual PhD5 Multi Gas Detector Reference Manual PhD5 Multi Gas Detector 651 South Main Street Middletown, CT 06457 USA (800) 711-6776 (860) 344-1079 Fax (860) 344-1068 http://www.biosystems.com Version 3.20 p/n 13-092 30NOV2006 2 THE

More information

WATCHMAN MULTIGAS MONITOR

WATCHMAN MULTIGAS MONITOR WATCHMAN MULTIGAS MONITOR 08-02-39 FEATURES Continuously monitors combustible gases, oxygen, carbon monoxide and other toxic gases simultaneously; displays gas concentrations over large, easy-to-read digital

More information

MiniRAE 3000 User s Guide

MiniRAE 3000 User s Guide MiniRAE 3000 User s Guide Rev. F February 2016 P/N 059-4020-000 FCC Information Contains FCC ID: PI4411B or SU3RM900 The enclosed device complies with part 15 of the FCC rules. Operation is subject to

More information

INNOVA Series. Instruction Manual Part Number

INNOVA Series. Instruction Manual Part Number INNOVA Series Instruction Manual Part Number 71-6417 5Aug2009 2007 Thermo Fisher Scientific Inc. All rights reserved. Specifications, terms and pricing are subject to change. Not all products are available

More information

Micro IV. Single Gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

Micro IV. Single Gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734) Micro IV Single Gas Detector Operations Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.gfg-inc.com Table of Contents Introduction....1 For Your Safety...1

More information

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions Important: Keep these User Instructions for reference 2 TABLE OF CONTENTS GENERAL SAFETY

More information

PRODUCT GUIDE. Gas Leak Detectors Gas Monitors Pipe & Joint Locators Calibration Stations Data Management MUNICIPAL SERVICES

PRODUCT GUIDE. Gas Leak Detectors Gas Monitors Pipe & Joint Locators Calibration Stations Data Management MUNICIPAL SERVICES Innovative Detection Solutions www.gasleaksensors.com MUNICIPAL SERVICES PRODUCT GUIDE Gas Leak Detectors Gas Monitors Pipe & Joint Locators Calibration Stations Data Management The Company: SENSIT Technologies

More information

Pioneer-R16 Gas Monitor Operator s Manual

Pioneer-R16 Gas Monitor Operator s Manual Pioneer-R16 Gas Monitor Operator s Manual Edition 7/2/97 RKI INSTRUMENTS, INC RKI Instruments, Inc. 33248 Central Ave, Union City, CA 94587 (510) 441-5656 Chapter 1: Description About the Pioneer-R16 Gas

More information

Innova Series Operator s Manual

Innova Series Operator s Manual Innova Series Operator s Manual PROPRIETARY STATEMENT Thermo GasTech owns proprietary rights in the information disclosed within. By receiving this document, the recipient agrees that neither this document

More information

multi-gas detector Go the distance, and save Wear yellow. Work safe.

multi-gas detector Go the distance, and save Wear yellow. Work safe. multi-gas detector Go the distance, and save GasAlertMax XT II is the smart, simple, economical way to compliance. Workers feel safe and incidents are minimized so everyone will be able to do more. That

More information

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Operations Manual TS400. Test Station for G450/G460 Gas Detector TS400 Test Station for G450/G460 Gas Detector Operations Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.goodforgas.com GfG Products for Increased Safety Congratulations

More information

SIRIUS. [ MultiGas Detector ] Instruction Manual. Manufactured by: MSA INSTRUMENT DIVISION P.O.Box 427, Pittsburgh, Pennsylvania 15230

SIRIUS. [ MultiGas Detector ] Instruction Manual. Manufactured by: MSA INSTRUMENT DIVISION P.O.Box 427, Pittsburgh, Pennsylvania 15230 SIRIUS [ MultiGas Detector ] Instruction Manual Manufactured by: MSA INSTRUMENT DIVISION P.O.Box 427, Pittsburgh, Pennsylvania 15230 [Europe] Rev.03 / 11 2010 10092677 Y-HLS / GB 1 Warranty and Liability

More information