JBS-100-ECP-A COMBINATION POWER CONNECTION BOX AND DIGITAL ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS
|
|
- Gavin Malone
- 5 years ago
- Views:
Transcription
1 JBS-100-ECP-A COMBINATION POWER CONNECTION BOX AND DIGITAL ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS JBS-100-ECP-A with Pyrotenax MI heating cable using required MI cable grounding kit JBS-100-ECP-A with Raychem heating cable APPROVALS Nonhazardous locations KIT CONTENTS Item Qty Description A 1 Lid C 1 Box with electronics E 1 Core sealer (for use with Raychem heating cables only) F 1 Battery connector H 1 Cable lubricant (for use with Raychem heating cables only) I 1 Cable tie J 1 MI cable grounding kit (ordered separately; P ) DESCRIPTION The DigiTrace JBS-100-ECP-A is an electric heat-tracing power connection / electronic controller combination housed in a NEMA 4X rated enclosure. It is designed for use only with Raychem BTV- CR, XL-Trace, BTV-CT, QTVR-CT, XTV-CT, VPL-CT, and Pyrotenax MI heating cables in nonhazardous locations. These kits may be installed at temperatures as low as 40 F ( 40 C). For easier installation store above freezing until just before installation. The controller can be programmed to maintain temperatures of 425 F (220 C). It operates at voltages from 100 to 277 Vac and can switch current up to 30 Amps. For technical support call Pentair Thermal Management at (800) TOOLS REQUIRED ADDITIONAL MATERIALS REQUIRED Catalog No: JBS-SPA A B C D E F G H I J K WARNING: This component is an electrical device that must be installed correctly to ensure proper operation and to prevent shock or fire. Read these important warnings and carefully follow all of the installation instructions. if the heating cable is damaged or improperly installed, and to comply with the requirements of Pentair Thermal Management, agency certifications, and the National Electrical Code, groundfault equipment protection must be used. Arcing may not be stopped by conventional circuit breakers. Pentair Thermal Management-specified parts only. Do not use substitute parts or vinyl electrical tape. short. They must be properly insulated and kept dry. strands when scoring the jacket or core. installation. wrap or flame-retardant foam. CAUTION: HEALTH HAZARD: Prolonged or repeated contact with the sealant in the core sealer may cause skin irritation. Wash hands thoroughly. Overheating or burning the sealant will produce fumes that may cause polymer fume fever. Avoid contamination of cigarettes or tobacco. Consult MSDS RAY5510 for further information. CHEMTREC 24-hour emergency telephone: (800) Non-emergency health and safety information: (800) / 14
2 For Raychem Heating Cables Bus wire Conductive core Braid Inner jacket Outer jacket Braid Inner jacket Conductive fiber Spacer Bus wire Outer jacket Braid Inner jacket Heating element Bus wire connection Clear jacket Insulated bus wire Outer jacket BTV-CR, BTV-CT, QTVR-CT, XL-TRACE XTV-CT VPL-CT 1 2 (60 cm) of heating cable for installation. For VPL, cut cable 12 in (30 cm) from bus indentation. at about 45 for easier insertion. Indentation on VPL heating cables only). 12 in (30 cm) installed on bottom side of pipe, knock out drain hole prior to inserting cable. desired direction of box opening, push 18 in (45 cm) of heating cable through stand. 90 cut. Drain hole 18 in (45 cm) Label on stand indicates direction of box opening. Do not attach stand to pipe until step jacket. Do not cut braid. 7 1/2 in (190 mm) 2 / 14
3 4 5A XL-TRACE, BTV and QTVR XL-TRACE, BTV and QTVR Go to Step 5a a pucker. driver to open braid. XTV Go to Step 5b VPL Go to Step 5c work it through opening in braid. jacket around and down as shown. 6 1/2 in (165 mm) 1/4 in (5 mm) bus wires at inner jacket. core material from bus wires. make pigtail. Go to Step 6 3 / 14
4 5B XTV 5C VPL a pucker. driver to open braid. as tight as possible. work it through opening in braid. jacket around and down as shown. 6 in (152 mm) jacket around and down as shown. 6 1/2 in (165 mm) cut and remove as shown. all fiber strands. jacket around and down as shown. 6 in (152 mm) center spacer. fiber material from bus wires. make pigtail. to break jacket at the score then peel off jacket. a screwdriver to open braid as shown. work it through opening in braid. ends of bus wires. make pigtail. 1/2 in (13 mm) Go to Step 6 Go to Step 6 4 / 14
5 6 7 as shown. Caution: Health Hazard. Wash hands after contact with sealant. Consult material safety data sheet RAY5510.] then insert into the guide tubes as shown. 5/8 in (15 mm) Make sure all strands go into the tubes. Tubes 8 heating cable to the mark made in Step 6. Note: Extra force may be at lower temperatures. 9 dispose of them in a plastic bag. Make sure the bus wires do not kink, bunch, or crossover /2 in (13 mm) 1/2 in (13 mm) 1 in (25 mm) 5 / 14
6 12 desired direction of box opening. Do not pinch heating cable. Note: For 1 in (25 mm) and smaller pipes use adapter (purchased seprately) and install between stand and pipe. 1in (25 mm) Glass cloth tape JBS-SPA adapter for small pipes Position adapter this side up. Pipe strap (Optional) To change direction of box opening: into one of the four notches in box. Notch tighten firmly to prevent box rotation. Connecting Heating Cable wires into the terminal block marked To Heating Cable and the heater s braid marked Earth and tighten terminals. Confirm connection by pulling on the wires. Power Terminal Block To Heating Cable Earth Line/ Neutral Line Trim Heating cable ground (braid) Self-regulating heating cable 6 / 14
7 17 18 Connecting RTD into the terminal block marked RTD Input. Match Confirm connection by pulling on the wires. Red RTD Input R R W White Connecting Alarm contact for remote annunciation of RTD failure and low/high temperature alarms. If an then alarm wiring can exit the enclosure via the 1/2 inch plugged hole or the 3/4 inch power conduit hole as long as the insulation rating of the control wiring is the same as the power wiring. Optional Alarm Contacts Com NC NO To user annunciation panel Com NO NC Alarm voltage up to 277 Vac (48 Vdc) Alarm device Normally energized; changes state upon an alarm. 19 minimize loosening due to pipe vibration, use flexible conduit. 1/2 in (13 mm) of insulation and terminate. Power Terminal Block Power In Line Line/ Neutral Earth Pentair Thermal Management recommends the use of a conduit drain to prevent water condensation build-up 20 diagram. GLCB Phase A Phase B Ground RTD Heating cable braid (ground) Self-regulating or MI heating cable 7 / 14
8 21 Programming the Controller that follows.) future reference. le Weather seal 8 / 14
9 For Pyrotenax MI Heating Cables Note: To ensure the MI heating cable is properly grounded, all MI cables must be installed with a grounding kit which is ordered separately (P ). Failure to use the grounding kit will void the warranty and can create a safety hazard by preventing normal operation of the ground fault circuit breaker. Design A Design D Heating cable length Cold lead length Heating cable length Cold lead length Design A: for single conductor cables only (61 series) Design D: for dual conductor cables only (32, 62 series) 1 grommet through bottom of stand. Plug 2 desired direction of box opening. Do not pinch heating cable. excess cold lead can be coiled before entering the box. Note: For 1 in (25 mm) and smaller pipes use adapter (purchased separately) and install between stand and pipe. JBS-SPA adapter for small pipes Position adapter this side up. 9 / 14
10 3 4 (Optional) To change direction of box opening: into one of the four notches in box. Notch 5 6 tighten firmly to prevent box rotation. plug and 1/2 in lock nut from side of enclosure. Trim 7 separately). hub and secure. and then secure with 1/2 inch lock nut. Conduit hub 1/2 in lock nut Grounding strap 10 / 14
11 8 9 Connecting Heating Cable cable wires into the terminal block marked To Heating Cable and the grounding strap to Earth and tighten terminals. Confirm connection by pulling on the wires. Grounding strap Power Terminal Block To Heating Cable Earth Line/ Neutral Line Connecting RTD the terminal block marked RTD Input. Match the colors (Reds terminals. Confirm connection by pulling on the wires. Red RTD Input R R W White MI heating cable 10 Connecting Alarm annunciation of low and high alarms. If an external enclosure via the 3/4 inch power conduit hole, as long the power wire. (Per NEC (c)). Optional Alarm Contacts Com NC NO Alarm Relay Form C: 2 A at 277 Vac, 2 A at 48 Vdc Normally energized; changes state upon an alarm. To user annunciation panel 11 shown. To minimize loosening due to pipe vibration, use flexible conduit. wires, strip off 1/2 in (13 mm) of insulation and terminate. Line Line/ Neutral Power Terminal Block Power In Earth Pentair Thermal Management recommends the use of a conduit drain to prevent water condensation build-up 11 / 14
12 12 diagram. Optional RTD Alarm Input Contacts Power Terminal Block GLCB Phase A Phase B Alarm Ground MI heating cable RTD 13 the Controller that follows.) reference. le Weather seal 12 / 14
13 Programming the Controller To program the controller, supply voltage to the controller in either of the following ways. 1A Powering Controller via Battery battery connector. controller marked Battery Connector. 1B Powering Controller via Line Power WARNING: Shock Hazard. Secure the wire cover in place with the four screws before proceeding. controller and heating cable. 9 Volt battery Ø Ø 2 Activating and Navigating the Menu in Set-up Mode Menu button for approximately 5 seconds. Up and Down buttons to change values. Next button to change to next display code/ parameter. Menu SETTINGS: 1 - *F or *C 2 - Set Point 3 - Deadband 4 - High Alarm 5 - Low Alarm Down Up Next 13 / 14
14 Parameters The first parameter displayed during set-up mode values, and minimum and maximum values, are shown in the following table. Display Code Parameter Default Min. Max. 1 F or C F 2 Maintain set point 40 F 32 F (0 C) 425 F (218 C) 3 Deadband 5 F 1 F (1 C) 10 F (10 C) 4 High Alarm 1 38 F (3 C) 482 F (250 C) 5 Low Alarm 2 20 F ( 6 C) 420 F (216 C) Note: 1. The minimum high temperature alarm set point must always be larger than the maintain set point plus the deadband plus 5 F (3 C). 2. The maximum low temperature alarm set point must always be smaller than the maintain set point minus the deadband. Alarms The following table lists the error or alarm codes and their respective faults: Alarm Relay Form C: 2 A at 277 Vac, 2 A at 48 Vdc Normally energized; changes state upon an alarm. Alarm / Error Codes rtd Err Hi Alr Lo Alr Fault Shorted or open RTD sensor High Temperature Alarm Low Temperature Alarm NORTH AMERICA Tel: Fax: Tel: Fax: thermal.info@pentair.com EUROPE, MIDDLE EAST, AFRICA Tel: Fax: thermal.info@pentair.com ASIA PACIFIC Tel: Fax: cn.thermal.info@pentair.com LATIN AMERICA Tel: Fax: thermal.info@pentair.com Pentair, DigiTrace, BTV, XL-Trace, QTVR, XTV, VPL and Pyrotenax are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice Pentair. PN P / 14
JB-RTD-STAND RTD PIPE STAND FOR COMBINATION POWER CONNECTION BOX AND ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS
JB-RTD-STAND RTD PIPE STAND FOR COMBINATION POWER CONNECTION BOX AND ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS JB-RTD-STAND with Raychem heating cable DESCRIPTION The Raychem JB-RTD-STAND is a combination
More informationJBS-100-EC Electronic controller replacement kit for JBS-100-ECP-A and JBS-100-ECW-A Installation Instructions
JBS-100-EC Electronic controller replacement kit for JBS-100-ECP-A and JBS-100-ECW-A Installation Instructions Description The Raychem JBS-100-EC is a replacement kit that can be used to replace the electronic
More informationC A Heating Cable Gland Kit
C75-100-A Heating Cable Gland Kit Installation Instructions Description The C75-100-A is a NEMA 4X rated gland kit used to transition heating cables into a junction box when making connections off of a
More information1SC-SSC Splice Connection Kit Installation Instructions
1SC-SSC Splice Connection Kit Installation Instructions Description The 1SC-SSC is a NEMA 4 rated splice connection kit for use with Raychem 1SC30, 40, 50, 60, 70, 80 (-CT) and 1SC/H30, 40, 50, 60, 70,
More informationFTC-HST WARNING: CAUTION:
FTC-HST XL-Trace, RaySol, and IceStop Splice/Tee Connection Kit Installation Instructions Description The Raychem FTC-HST is used with RaySol system heating cables to make splice connections (on slab bottoms
More informationHWT-P HWAT POWER CONNECTION KIT WITH END SEAL INSTALLATION INSTRUCTIONS
HWT-P HWAT POWER CONNECTION KIT WITH END SEAL INSTALLATION INSTRUCTIONS DESCRIPTION The Raychem HWT-P Power Connection and End Seal Kit is for use with HWAT heating cables. Materials for one power connection
More informationJBM-100-LBTV2 Power Connection, Powered Splice, Dual Power Connection, or Splice with Junction Box
JBM-100-LBTV2 Power Connection, Powered Splice, Dual Power Connection, or Splice with Junction Box Installation Instructions Description The JBM-100-LBTV2 is a Type 4X-rated connection kit. It is designed
More informationTHERMAL MANAGEMENT SOLUTIONS
DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL ECW-GF with FTC-PSK pipe stand and power connection kit ECW-GF using RayClic power connection kit ECW-GF-DP remote display panel available only with
More informationTHERMAL MANAGEMENT SOLUTIONS
Pipe Freeze Protection and Flow Maintenance ECW-GF, ECW-GF-DP Digital electronic controllers and remote display panel Fire Sprinkler System Freeze Protection ECW-GF with FTC-PSK pipe stand and power connection
More informationCSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines
CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines System for flow maintenance of aboveground fuel oil lines with Proportional Ambient Sensing Control (PASC),
More informationECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW
DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL ECW-GF with FTC-PSK pipe stand and power connection kit ECW-GF using RayClic power connection kit ECW-GF-DP remote display panel available only with
More informationFreezGard. Self-regulating crankcase heater. Product Overview
Self-regulating crankcase heater Product Overview When compressors operate in cold areas, refrigerant can migrate into the crankcase oil whenever the compressor is not running. On start-up, this can cause
More informationCSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines
CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines System for flow maintenance of above ground greasy waste disposal lines with line sensing control,
More informationLongline Heating. Contents. Introduction
Longline Heating This section provides an overview of the longline heat-tracing technologies available from Pentair Industrial Heat Tracing Solutions. For complete design assistance, contact your Pentair
More informationRayClic Connection System
RayClic Connection System RayClic-S Splice Kit RayClic-T Tee and End Seal Kit RayClic-X Cross and End Seal Kit Installation Instructions Description These kits are for use with Raychem IceStop, XL-Trace
More informationFrost Heave Protection System Installation and Operation Manual
Frost Heave Protection System Installation and Operation Manual FHPC Constant Power Density Heating Cable Systems Thermal management solutions EN-RaychemFHPS-IM-INSTALL103 R1 WARNING: Fire and Shock Hazard.
More informationNGC-UIT-ORD User interface terminal for Raychem NGC systems Installation Instructions
NGC-UIT-ORD User interface terminal for Raychem NGC systems Installation Instructions Description The NGC-UIT-ORD is a panel mounted display used in conjunction with other approved Raychem control and
More informationCSI Master Format 2012 Guide Specification for: Hot Water Temperature Maintenance (HWAT) Systems
CSI Master Format 2012 Guide Specification for: Hot Water Temperature Maintenance (HWAT) Systems System for temperature maintenance of domestic hot water supply systems with energy efficient time based
More informationHS-TSPLICE - HEATSHRINK TEE / SPLICE. Installation Instructions
- HEATSHRINK TEE / SPLICE This kit is only for use with the following Drexan HeatTracer Self-Regulating heater products: PipeGuard Warm (PGW), MultiTrace (MT) and HotTape (HT). CAUTION: A ground fault
More informationCSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated)
CSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated) Typical system for snow melting of pavers, concrete and asphalt surfaces with temperature and moisture sensing control,
More informationTHERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16
TraceTek TTSIM-1A TraceTek Sensor Interface Module with Relay Installation/OPERATION Instructions Approvals and Certifications TYPE NM General Signaling Equipment 76LJ Only AC versions are UL listed and
More informationHEATING CABLE RATINGS APPROVALS* Drexan Energy Systems, Inc. Kelowna, BC, Canada, V4V 1S5
DREX0019 Division 1 Adapter Kit Single Cable These installation instructions are only for use with the following Drexan HeatTracer heater products: Self-Regulating (PipeGuard Warm (PGW), MultiTrace (MT)
More informationHOT WATER TEMPERATURE MAINTENANCE HWAT SYSTEM
HOT WATER TEMPERATURE MAINTENANCE HWAT SYSTEM This step-by-step design guide provides the tools necessary to design a Raychem HWAT Hot Water Temperature Maintenance System. For additional information,
More informationCSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)
CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated) System for preventing frost heave in freezers, cold rooms and ice arenas with temperature control, monitoring,
More informationTTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS
TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS GENERAL INFORMATION Please read these instructions and keep them in a safe place. These instructions must
More informationTOUCH 1500 User Interface Terminal for Raychem NGC Systems Installation Instructions
TOUCH 1500 User Interface Terminal for Raychem NGC Systems Installation Instructions Approvals / Certifications Hazardous Locations Class I, Division 2 Groups A, B, C, D Touch 1500-HAZ-CPU and Touch 1500-HAZ-TS
More informationTT3000 and TT5000 Series
TT3000 and TT5000 Series Bulk Sensing Cable Installation Instructions General Notes Do s and Don ts General Information These instructions detail techniques used to install TT3000 or TT5000 bulk sensing
More informationNGC-UIT2-ORD-R Remote User Interface Terminal for Raychem NGC Systems Installation Instructions
NG-UIT2-ORD-R Remote User Interface Terminal for Raychem NG Systems Installation Instructions Description The NG-UIT2-ORD-R is a wall-mounted display which allows the User Interface Terminal (UIT) to be
More informationsulfur transport pipelines Safe, Reliable and Cost-Effective Heat Management System
sulfur transport pipelines Safe, Reliable and Cost-Effective Heat Management System INDUSTRIAL HEAT TRACING SOLUTIONS WWW.pentairthermal.com industrial solutions As the world s largest provider of complete
More informationFIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM
FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM This step-by-step design guide provides the tools necessary to design a Raychem XL-Trace fire sprinkler freeze protection system. For other applications
More informationXL-Trace System. Installation and Operation manual for pipe freeze protection and flow maintenance
XL-Trace System Installation and Operation manual for pipe freeze protection and flow maintenance Thermal management WWW.PENTAIRTHERMAL.COM Important Safeguards and Warnings WARNING: FIRE AND SHOCK HAZARD.
More informationC Electrical Connection Kit
1548-4010C Electrical Connection Kit For Use With Dekoron 2700 and 2300 Family of Heating Cables Installation Instructions Kit Description The Dekoron 1548-4010C electrical connection and end seal kit
More informationPipe Freeze Protection. Flow Maintenance. Introduction. XL-Trace System
Pipe Freeze Protection and Flow Maintenance 1. Pipe Freeze Protection and Flow Maintenance Introduction XL-Trace System This step-by-step design guide provides the tools necessary to design a Raychem XL-Trace
More informationDesign Guide Design Notes Design Examples Technical Data Sheets Expanded Capabilities Specifications Warranty
Introduction HWAT Design Guide This step-by-step design guide provides the tools necessary to design a Raychem HWAT Hot Water Temperature Maintenance System. For additional information, contact your Pentair
More informationTraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM
TTC-1 TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION The nvent RAYCHEM TraceTek TTC-1 sensing module is used with TraceTek sensing cables to detect liquid leaks.
More informationINDUSTRIAL HEAT TRACING SOLUTIONS PRODUCTS & SERVICES
PRODUCTS & SERVICES WWW.PENTAIRTHERMAL.COM ADVANCED INDUSTRIAL SOLUTIONS As the world s largest provider of complete electrical heat management systems, primarily for the general process, oil and gas,
More informationADVANCED INDUSTRIAL SOLUTIONS HEAT-TRACING PRODUCTS & SERVICES
ADVANCED INDUSTRIAL SOLUTIONS HEAT-TRACING PRODUCTS & SERVICES THERMAL MANAGEMENT SOLUTIONS WWW.Pentairthermal.COM ADVANCED INDUSTRIAL SOLUTIONS As the world s largest provider of complete electrical heat
More informationXL-Trace System Application and Design Guide
R XL-Trace System Application and Design Guide Pipe Freeze Protection and Flow Maintenance for Commercial Construction Applications Pipe Freeze Protection and Flow Maintenance 1. Pipe Freeze Protection
More informationData Sheet. Self regulating process heating tapes RS stock numbers ,
Data Pack K Issued March 1997 232-3333 Data Sheet Self regulating process heating tapes RS stock numbers 379-889, 379-974 The information contained within this sheet regarding applications and installation
More informationXL-Trace System Installation and Operation Manual
XL-Trace System Installation and Operation Manual Pipe freeze protection and flow maintenance WARNING: Fire and shock hazard. This heat-tracing system must be installed correctly to ensure proper operation
More informationH908 WinterGard Plug-in Power Connection Kit with End Seal
R R H908 WinterGard Plug-in Power Connection Kit with End Seal Installation Instructions Description The H908 is a plug-in, ground-fault-protected power connection kit for use with WinterGard H311, H611,
More informationNELSON HEAT TRACING SYSTEMS
DESCRIPTION The PLT-BY Tee Splice Connection Kit is for use with all versions of Nelson Heat Tracing Systems LT, CLT, HLT and NC heater cables. Compatible for use with any vendor s heater cables small
More information910 Series Single-point heat-tracing control system
Single-point heat-tracing control system 910*E1FWL*SSR2 Product overview The Raychem 910 is a compact, full-featured, microprocessor-based, single-point heat-tracing control system. The 910 provides control
More informationCOMMERCIAL & RESIDENTIAL SELF-REGULATING HEATING PRODUCTS APPLICATION AND DESIGN GUIDE EUROPE, MIDDLE EAST, AFRICA
WWW.PENTAIRTHERMAL.COM NORTH AMERICA Tel: +1.800.545.6258 Fax: +1.800.527.5703 Tel: +1.650.216.1526 Fax: +1.650.474.7711 thermal.info@pentair.com ASIA PACIFIC Tel: +86.21.2412.1688 Fax: +86.21.5426.2917
More informationNGC-40-IO Control and monitoring modules for use with the Raychem NGC-40 system Installation Instructions
NGC-40-IO Control and moniting modules f use with the Raychem NGC-40 system Installation Instructions A DESCRIPTION The NGC-40-IO provides up to four additional RTD inputs. These additional RTD inputs
More informationDual-point heat-tracing control system
Dual-point heat-tracing control system 920*E4FWL*SIS302*SS3102 shown Product overview The Raychem 920 is a compact, full-featured, microprocessor-based, dual-point heat-tracing control system. The 920
More informationHHS-WWH HOPPER HEATING SYSTEM WRAP-WOUND HEATER INSTALLATION INSTRUCTIONS DESCRIPTION. HHS-WWH PRODUCT SPECIfICATIONS
HHS-WWH HOPPER HEATING SYSTEM WRAP-WOUND HEATER INSTALLATION INSTRUCTIONS HHS-WWH PRODUCT SPECIfICATIONS Power density Standard wattages up to 4650 W/m² (3.0 W/in²) Voltage range (nominal) 120 to 600 VAC
More informationNELSON HEAT TRACING SYSTEMS ALT-BC STANDARD POWER CONNECTION KIT
DESCRIPTION The ALT-BC Standard Power Connection Kit is constructed of cast aluminum for use with all versions of Nelson Heat Tracing Systems LT, CLT, HLT and NC heater cables. Compatible for use with
More informationHTC-915-CONT. Heat-Trace Control system
Heat-Trace Control system Product overview The Raychem HTC-915 system is a compact, full-featured microprocessor-based single-point heat-trace controller. The HTC-915-CONT provides control and monitoring
More informationDESCRIPTION. 42 mm. 125 mm
RMM2-DI TRACE-HEATING REMOTE MONITORING MODULE FOR DIGITAL INPUTS DESCRIPTION 125 mm 60 mm The Remote Monitoring Module for Digital Inputs (RMM2-DI) provides the capability for the Raychem NGC controller
More informationNELSON HEAT TRACING SYSTEMS
DESCRIPTION The PLT-L Series End of Circuit Light Kit is for use with all versions of LT, CLT, HLT and NC heater cables. Compatible for use with any vendor s heater cables smaller than 11mm (.44 ) diameter.
More informationPipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual
MANUAL Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual Model FPT 130 Single Point Freeze Protection Heat Trace Control Table of Contents SCFP-CO-F130 Overview... 3 Installation...
More informationSensor Interface Module Installation/Operation Instructions
TraceTek TTSIM-1 Sensor Interface Module Installation/Operation Instructions Approvals and Certifications TYPE NM General Signaling Equipment 76LJ Only AC versions are UL listed and VDE Certified. For
More informationC SINGLE-POINT HEAT-TRACING CONTROL SYSTEM. product overview
C910-485 SINGLE-POINT HEAT-TRACING CONTROL SYSTEM product overview ALARM SHIFT TEST C910 SERIES MONITOR CONFIG BACK ENTER PROGRAMMABLE SINGLE POINT HEAT-TRACING CONTROLLER STATUS ALARM OUTPUT The DigiTrace
More informationNGC-40 Advanced Heat-Tracing Control System
NGC-40 Advanced Heat-Tracing Control System Local configuration and monitoring with Raychem Touch 1500 touch screen display Heat-tracing system NGC-40 system Remote configuration and monitoring with Raychem
More informationSMPG3 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL. For three-phase heating cables PRODUCT OVERVIEW
SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL For three-phase heating cables Mounting brackets Nameplate HTC energized light Power on light Heater cycle timed control Heater (3R only)
More informationSingle Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual
We manage heat MANUAL Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239
More informationFreezer Frost Heave Prevention
Freezer Frost Heave Prevention 1. Pipe Freeze Protection and Flow Maintenance RaySol System Mineral Insulated Heating Cable System This step-by-step design guide provides the tools necessary to design
More informationNELSON HEAT TRACING SYSTEMS
DESCRIPTION The ALT- continuity monitor device is used to monitor bus continuity on a parallel type heater cable. After the heater cable is installed on the pipe, connect the ALT- to the opposite end of
More informationNELSON HEAT TRACING SYSTEMS
DESCRIPTION The SLT-LPS Entry Seal Kit provides a watertight entry into a junction box suitable for this application. This kit includes cable seals for power and end terminations. The SLT-LPS kit is designed
More informationUnion County Vocational - Technical Schools Scotch Plains, New Jersey
SECTION 220533 - HEAT TRACING FOR PLUMBING PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes plumbing piping heat tracing for freeze prevention, domestic hot-water-temperature maintenance, and
More informationINSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS
RV Products Division INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330C755 CONTROL BOX KIT (12 VDC HEAT READY) 8530-750 CONTROL BOX KIT
More informationNGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X
NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS Firmware versions up to V2.0.X INDUSTRIAL HEAT TRACING SOLUTIONS EN-RaychemNGCUIT2Protocol-IM-H57880 06/15 1/32 Contents Section I Introduction
More informationSkin-Effect Heat-Tracing System (STS)
Skin-Effect Heat-Tracing System (STS) INDUSTRIAL HEAT TRACING SOLUTIONS WWW.pentairthermal.com Cairn India ENGINEERED SOLUTIONS Pentair Industrial Heat Tracing Solutions offers innovative integrated technologies
More informationNELSON HEAT TRACING SYSTEMS INSTALLATION
DESCRIPTION The ALT-BY Tee Splice Connection Kit is constructed of cast aluminum for use with all versions of Nelson Heat Tracing Systems LT, CLT, HLT and NC heater cables. Compatible for use with any
More informationNELSON HEAT TRACING SYSTEMS
DESCRIPTION The ALT-LPM Power Connection Kit without Enclosure is constructed of cast aluminum for use with all versions of Nelson Heat Tracing Systems LT, HLT & NC heater cables. Compatible for use with
More informationMODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL
TRACON MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TABLE OF CONTENTS FPT 130 Overview... 2 Installation... 3 Power Source and Load Connections... 4 Temperature Sensor... 5 External
More informationTank Heating. Introduction. Self-Regulating Heating Cables
Tank Heating This step-by-step design guide provides the tools necessary to design a tank heating system for temperature maintenance using electric heating cables or tank heating pads. For design assistance,
More informationInstallation Instructions. For the 18 Built-In Dishwasher and Front Color Panels
Installation Instructions For the 18 Built-In Dishwasher and Front Color Panels Printed in USA 154232102 Before You Begin DO NOT INSTALL DISHWASHER UNTIL YOU HAVE READ ALL INSTRUCTIONS. FOR YOUR SAFETY,
More informationPLSRR Heat Trace Cable Data Sheet
PLSRR Heat Trace Cable Data Sheet PLSRR is self-regulating heat cable that can be used for roof / gutter heating pipe tracing. The cable features a flexible, UV-stabilized thermoplastic elastomer overjacket
More informationConsignes d installation
PBS-200-A Single entry power junction box Installation Instructions PBS-200-A Single entry power junction box with cold applied connection technology for use with BARTEC PSB / HSB trace heaters Consignes
More informationDual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual
We manage heat MANUAL Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239
More informationCOMMERCIAL HEAT TRACING PRODUCTS AND SERVICES
COMMERCIAL HEAT TRACING PRODUCTS AND SERVICES THERMAL MANAGEMENT SOLUTIONS WWW.THERMAL.PENTAIR.COM BUILDING & INFRASTRUCTURE SOLUTIONS We provide quality solutions for winter safety, comfort and performance
More informationData Sheet. Self regulating heating tapes. RS stock numbers
Data Pack K Issued September 2001 232-3125 Data Sheet Self regulating heating tapes RS stock numbers 379-312 The information contained within this sheet regarding applications and installation of RS WinterGard
More informationSelection guide for self-regulating heat-tracing systems
R Selection guide for self-regulating heat-tracing systems R TraceCalc Net, software design in three easy steps: 1. Select your heat-tracing design 2. Enter the design data >> 3. Get a bill of materials
More informationKE-Series Constant-Wattage Heating Cable
KE-Series Constant-Wattage Heating Cable Installation Instructions Read and understand this material before installing this heater. Failure to understand how to safely install the heater could result in
More informationINSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP
INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1976-360 (1-02) PP TABLE OF CONTENTS 1. Warnings......................................................
More informationRAYCHEM NGC-30 COMPONENTS
PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM PRODUCT OVERVIEW CABLE DUCT Card Rack Modules TERMINAL STRIP PLINTH MAIN SWITCH 800 mm USER INTERFACE
More informationSMPG1 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL FOR SINGLE-PHASE HEATING CABLES PRODUCT OVERVIEW
SMPG1 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL FOR SINGLE-PHASE HEATING CABLES Mounting brackets Heater thermostat (3R only) Power on light HTC energized light Heater (3R only) Snow/Ice
More informationINSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT
RV Products Division INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330A755 CONTROL BOX KIT (12 VDC HEAT/COOL) 8530-750 CONTROL BOX KIT (24 VAC COOL ONLY)
More informationTraceTek Sensing Cable for Aboveground Leak Detection Installation Instructions
TT5000-HUV (for fuel leaks) TT5001-HUV (for solvent leaks) TraceTek Sensing Cable for Aboveground Leak Detection Installation Instructions TT5000-HUV sensing cable is identified by the red tracer in the
More informationMODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT
TRACON MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT TABLE OF CONTENTS GPT 130 Overview... 2 Installation... 3 Power Source and Load Connection... 4 Temperature Sensor Installation... 5 Panel
More informationTechnical Databook for Industrial Heat-Tracing Systems 2006/2007
R Technical Databook for Industrial Heat-Tracing Systems 2006/2007 www.tycothermal.com Tyco Thermal Controls brings together the knowledge, expertise, products and services of the leading brands in industrial
More informationC910 Series. Single-point heat-tracing control system
1. Pipe Freeze Protection and Flow Maintenance Single-point heat-tracing control system 2. Roof and Gutter De-Icing Product overview The DigiTrace C910 is a compact, fullfeatured, microprocessor-based,
More informationGardian W51. Approvals
Gardian W51 120 V pre-assembled electric heating cables for pipe freeze protection and roof & gutter de-icing Installation Instructions Description Gardian W51 120 V pre-assembled self-regulating heating
More informationInstallation Instructions for W2H Series Signals
Installation Instructions for W2H Series Signals IF1513 A Description and Operation DIMENSIONS W2H A 8 7/8" (225 mm) B 8 1/4" (210 mm) C 13" (330 mm) Figure 1. Speaker/Amplifier Dimensions The W2H signaling
More informationINSTALLATION INSTRUCTIONS FOR MOUNTING KIT
RV Products Division INSTALLATION INSTRUCTIONS FOR 8330-5501 MOUNTING KIT 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330B755 CONTROL BOX KIT (12 VDC HEAT/COOL) 8530-750 CONTROL BOX KIT (24 VAC COOL ONLY)
More informationINDUSTRIAL HEAT TRACING SOLUTIONS. Products & Services
INDUSTRIAL HEAT TRACING SOLUTIONS Products & Services Services ADVANCED INDUSTRIAL SOLUTIONS As the world s largest provider of complete electrical heat management systems, primarily for the general process,
More informationSEALING FIBER SEALING COMPOUND
ARCTIC TRACE INSTALLATION INSTRUCTIONS Type GUAT26C Hazardous Location Power Connection and Butt Splice Kit for Temperature Limiting Submersible Heating Cable JUNCTION BOX SEALING FIBER SEAL OFF SEALING
More informationPANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm
PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM Card Rack Modules CABLE DUCT MAIN SWITCH 800 mm USER INTERFACE TERMINAL PRODUCT OVERVIEW The nvent
More informationHWAT -ECO. Installation and Operation Manual. Electronic controller for hot water temperature maintenance systems
HWAT -ECO Installation and Operation Manual Electronic controller for hot water temperature maintenance systems B A C F HWAT -ECO Installation and Operation Manual D Electronic controller for hot water
More informationSERGE BARIL GTKB GUT TRACE KIT BAG
Description: The GTKB Gut Trace Kit Bag includes the power cord connection with the GFI Plug and end seal. It is for use with FPS-BT & IN-PIPE type heater cables. Kit Contents: 1 Compression Fitting 3
More informationSAFETY INFORMATION AND WARNINGS
This manual refers to the Model SST-3 control panel manufactured since October 31, 2013, which uses a universal (100 277 VAC; 50/60 Hz) power supply. Older units use a voltage-specific power supply and
More informationTT3000 and TT5000 Series
TT3000 and TT5000 Series Modular Sensing CableS Installation Instructions General Information These instructions explain the proper procedures for installing and testing TT3000 and TT5000 series modular
More informationInstallation Instructions
Installation Instructions For the 18" Built-In Dishwasher Sears, Roebuck and Co. Sears Canada, Inc. Hoffman Estates, IL 60179 U.S.A. Toronto, Ontario, Canada M5B 2B8 154435201 Before You Begin DO NOT INSTALL
More informationPower-Limiting Cables
Power-Limiting 1. Self- Regulating 2. Power- Limiting This section provides general design guidelines for power-limiting heat-tracing systems installed on insulated metal pipes. For other applications
More informationDESTU. Direct Entry Sealed Termination Unit. Installation Instructions. Suitable for use in either safe or hazardous areas.
DESTU Direct Entry Sealed Termination Unit Installation Instructions Suitable for use in either safe or hazardous areas R II 2 G EEx e II Heat Trace Limited, Mere s Edge, Chester Road, Helsby, Frodsham,
More informationRaychem Heating System
Raychem Heating System Tank Heater (H55207) Approvals F M APPROVED Ordinary and Hazardous Locations lass I, Div. 2, Groups B,, D lass II, Div. 1 & 2, Groups E, F, G lass III All hazardous location applications
More informationrev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM
216279-000 rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM IDENTIFYING YOUR SYSTEM IOM216279-000 The HOTSTART heating system is designed to heat fluids for use in marine
More informationDual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual
We manage heat MANUAL Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239
More information