1 Qualification Test Report /Mar/2014 Rev A MPOptimate FO Microcassette 12 fiber MPO-12xLC/PC 1. INTRODUCTION 1.1 Purpose Tests performed on MPOptimate FO Microcassette 12 fiber MPO-12xLC/PC, to determine its conformance to the requirements of TE Connectivity Product Specification , Rev. C. 1.2 Scope This report covers the mechanical, environmental and transmission performance of the MPOptimate FO Microcassette 12 fiber MPO-12xLC/PC manufactured by TE Connectivity. The testing was performed between February 10 th and February 25 th, Conclusion Tested MPOptimate FO Microcassette 12 fiber MPO-12xLC/PC meet the mechanical, environmental and transmission performance requirements of TE Connectivity Product Specification Rev. C. 1.4 Product Description The MPOptimate FO Microcassette 12 fiber MPO-12xLC/PC comprise a fan out from one 12 fibre MPO connector to 12 single fibre connectors, is intended for use in networking applications where density and high performance is required. 1.5 Test Samples Tested samples were selected from normal current production lots, and the following part numbers (PN) were used for the tests: 12 samples of MPOptimate FO Microcassette 12 fiber MPO-12xLC/PC straight PN samples of MPOptimate FO Microcassette 12 fiber MPO-12xLC/PC flipped PN TE Connectivity AMP España, S.L.U., Barcelona (Spain) a TE Connectivity Ltd. Company. All International Rights Reserved * Trademark 1 of 6 Indicates change TE logo is a trademark LOC IK
2 1.6 Qualification Test Sequence Test No Test Source 1 Attenuation (random mated) -- 2 Return loss (random mated) 1 3 Vibration (sinusoidal) 7 * 4 Strength of coupling mechanism 2 5 Mating Durability -- 6 Bending moment 8 7 Impact -- 8 Mechanical shock -- 9 Change of temperature -- * 10 Damp heat Steady state 11 * 11 Cold 12 * 12 Dry Heat 9 * All the test groups were composed by 4 samples. The 12 channels of each sample were tested. NOTE: Only 9 LC channels were tested for mating durability test. *All 12 channels of each cassette monitored during the test According Product Specification, tests may be performed in any order. The test order followed to perform all the tests is the indicated on the table. Rev A 2 of 6
3 2. SUMMARY OF TESTING RESULTS 2.1 General examination All Groups. All samples submitted for testing were selected from normal current production lots. 2.2 Attenuation (random mated) Group 1. All Attenuation measured values were lower than 0.35 db (maximum specified value). 2.3 Return loss (random mated) Group 1. All Return Loss measured values were higher than 27 db (minimum specified value). 2.4 Vibration (sinusoidal) Group 2. No increases higher than 0.2 db equal or greater than 2 milliseconds duration were detected. All tested samples meet visual requirements, show no physical damages and meet the optical performance requirements: Att.: Initial and final 0.35 db. Att. max change during test: 0.20 db. RL: Before and after test 27 db. 2.5 Strength of coupling mechanism Group 3. All tested samples meet the requirements for the performed test. Att.: Initial and final 0.35 db. Att. increase during test: 0.20 db. RL: Before and after test 27 db. 2.6 Mating Durability Group 4. All the connectors tested were cleaned less than 20 times after 50 operations in MPO side and 500 operations on LC side. Att.: Initial and final 0.35 db. 2.7 Bending moment Group 5. All tested samples show no physical damages after bending in the 4 perpendicular directions and meet the optical performance requirements: Att.: Initial and final 0.35 db. Att. increase during test: 0.20 db. RL: Before and after test 27 db. Rev A 3 of 6
4 2.8 Impact Group 6. All tested samples show no physical damages after 5 impacts and meet the optical performance requirements: Att.: Initial and final 0.35 db. RL: Before and after test 27 db. 2.9 Mechanical shock Group 7. Att.: Initial and final 0.35 db. RL: Before and after test 27 db Change of temperature Group Damp heat Steady state Group Cold Group Dry Heat Group 8. Rev A 4 of 6
5 3. TEST METHODS 3.1 General examination. (Reference Standard: IEC , Ed. 1 Feb 02). Product drawings and inspections plans were used to examine the samples. They were examined visually and functionally. 3.2 Attenuation (random mated) (Reference Standard: IEC , Ed. 3.0 Jan 09). Samples were connected to a Light Source/RL meter. The Power Meter takes the reference of the light power value at the end of the reference cable. Sample was connected between the reference cable and the Power Meter. The attenuation value (Att.) is the difference between power meter measurement in db when the sample is connected and the reference value in db. Initial Attenuation ( Att. ) were measured on each microcassette using 10 different MPO connectors. 3.3 Return loss (random mated) (Reference Standard: IEC , Ed. 3.0 Dec 12). Samples were connected to a Light Source/RL meter. The Return Loss reference were taken at the end of the reference cable. Connecting the reference cable to the sample, the Return Loss Meter measures the RL value on the reference point. Return Loss ( RL ) were measured on each microcassette using 10 different MPO connectors. 3.4 Vibration (sinusoidal) (Reference Standard: IEC , Ed. 3.0 Aug 09). Samples were placed in a vibration header and a sinusoidal motion was applied. Frequency range: 10 to 55 Hz at 1 octave/min rate. Amplitude: 0.75 mm peak ( 1.5 mm peak to peak ). Duration: 30 minutes on each of the three perpendicular axis It is not allowed any attenuation variation higher than 0.2 db and greater than 2 milliseconds. Samples should remain mated and will not show evidence of physical damage. 3.5 Strength of coupling mechanism: (Reference Standard: IEC , Ed. 2.0 Dec 10). Samples were placed in a universal force testing machine and an axial force of 40 N was applied to the mated connector. Application time: more than 30 seconds. Recovery time: 5 minutes. Attenuation and Return Loss were measured before, during and after the test. 3.6 Mating Durability: (Reference Standard: IEC , Ed. 3.0 Jan 09). Samples were submitted to mating and unmating cycles ( 500 for MPO connectors and 50 for LC connectors ). Attenuation and Return Loss values were measured after each operation. If the values measured do not meet the requirement, the connector must be cleaned. If the number of cleaning operations are bigger than 20, the connector do not meet the requirements. Rev A 5 of 6
6 3.7 Bending moment: (Reference Standard: IEC , Ed. 2.0 May 13). Samples were subjected in a universal force testing machine and a load of 10 N was applied using a steel probe during at least 10 seconds over the LC connectors. All the samples were tested on the 4 perpendicular directions. Attenuation and Return Loss were measured before, during and after the test. 3.8 Impact (Reference Standard: IEC , Ed. 3.0 Jul 09). Samples were unmated and subjected to a fiber optic lead with the dust covers placed on its position. Samples were released 5 times from the 1.5 meter height. Attenuation and Return Loss were measured before and after test. 3.9 Mechanical shock (Reference Standard: IEC , Ed. 2010). 12 shocks were applied to the samples ( 2 on each direction of the three perpendicular axis ). Half sine wave. Acceleration: 2000 m/s 2. Duration: 1 ms. Attenuation and Return Loss were measured before and after test Change of temperature (Reference Standard: IEC , Ed. 2 Feb 07). Samples were placed into a climatic chamber and submitted to 5 temperature cycles from -10º C to 60º C. The time at the extremes temperatures was 1 hour and the rate of change of the temperatures was 1º C/min Damp heat Steady state (Reference Standard: IEC , Ed. 3.0 Nov 11). Samples were placed into a climatic chamber and submitted to 60º C during 96 hours Cold (Reference Standard: IEC , Ed. 2 Feb 02). Samples were placed into a climatic chamber and submitted to -10º C during 96 hours Dry Heat (Reference Standard: IEC , Ed. 2 Jul 05). Samples were placed into a climatic chamber and submitted to 40º C and 93% RH during 96 hours. Test equipment identification and calibration traceability is kept in the laboratory files. Optical measurements were done using EF modal condition in accordance with IEC Rev A 6 of 6
Qualification Test Report LC Duplex Adapter For LC Cutouts
Qualification Test Report LC Duplex Adapter For LC Cutouts 501-683 09Mar09 Rev B 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics LC Duplex Adapters for LC Cutouts, to determine their
More informationQualification Test Report. AMP-TWIST Series Jacks for Class EA systems
Qualification Test Report 501-93032 14/April/2011 Rev A AMP-TWIST Series Jacks for Class EA systems 1. INTRODUCTION 1.1 Purpose Qualification testing on AMP-TWIST* Series Jacks for Class E A Systems, to
More informationApr06 Rev A
Qualification Test Report LC, Multimode, One-Piece Housing, Fiber Optic Connector 501-628 03Apr06 Rev A 1. INTRODUCTION 1.1. Purpose 1.2. Scope Testing was performed on Tyco Electronics LC multimode, one-piece
More informationMar11 Rev B
Product Specification 108-1576-2 11Mar11 Rev B NETCONNECT*, CHAMP* System 5 Modular Jack Patch Panel 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for NETCONNECT*
More informationProduct Specification Qualification Test Report
PS 88 / DMI PC SM / 6/5 DIAMOND Test & Calibration Laboratory STS 333 / SCS 11 Product Specification Qualification Test Report DMI PC SM DIAMOND SA Via dei Patrizi 5 CH-6616 LOSONE Tel. +41 91 785 45 45
More informationJan07 Rev B
Qualification Test Report 501-545 05Jan07 Rev B MT-RJ Patch Panel and Outlet Jacks (Standard, XG, SECURE and SECURE XG) 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics MT-RJ Jack,
More informationJul07 Rev C
Product Specification 108-2167 11Jul07 Rev C MPO and MPO SECURE Multimode Fiber Optic Connector and Adapter 1. SCOPE 1.1. Content This specification, which is based on GR-1435-CORE, covers the performance,
More informationQualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)
Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable) 501-586 26Feb09 Rev F 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics LightCrimp*
More informationMar11 Rev C
Product Specification 108-1441 11Mar11 Rev C Connector, Z-PACK*, 2 mm FB, Signal and Power 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the Z-PACK* 2mm
More informationFree Height 0.8 mm Pitch Board-to-Board Connector (SMT)
Product 108-5390 Specification 31 OCT 17 Rev.F1 Free Height 0.8 mm Pitch Board-to-Board Connector (SMT) 1. SCOPE 1.1. Contents This specification covers the requirements for product performance, test methods
More informationQualification Test Report 1/Jul/2005 Rev. A
Qualification Test 501-93013 Report 1/Jul/2005 Rev. A AMP CO 10 Gigabit/s Insert PN 1711188-X 1. INTRODUCTION 1.1 Purpose Testing was performed on AMP* CO 10 Gigabit/s Insert, to determine its conformance
More informationJUL 18 Rev A1
Qualification Test Report 501-166004 30 JUL 18 Rev A1 Mini USB-B Header, H-Type SMT 1. INTRODUCTION 1.1. Purpose Testing was performed on the Mini USB-B Header, H-Type SMT to determine if it meets the
More informationCopper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.
Product Specification 108-93018 25/Aug/2011 Rev H Copper LAN cable 1. SCOPE 1.1. Content This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. 2. APPLICABLE DOCUMENTS
More information/Oct/2014 Rev E
Product Specification 108-93017 14/Oct/2014 Rev E Cat 6 Unshielded Patch Cords 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for TE Connectivity
More information/Oct/2014 Rev B
Product Specification 108-93042 07/Oct/2014 Rev B Class EA shielded solid Patch cords 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for TE
More informationJan05 Rev A EC
Product Specification Two Circuit Heavy Duty Burner Connector 108-1056 12Jan05 Rev A EC 0990-0059-05 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the
More informationTwo Circuit Heavy Duty Burner Connector
Product 108-1056 11 Oct.16 Rev B Specification EC 0990-0059-05 Two Circuit Heavy Duty Burner Connector 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the
More informationPRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector
PRODUCT SPECIFICATION 108-115057 29OCT13 Rev. A1 0.5mm Fine Stacking Hermaphroditic Type BTB Connector 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for 0.5mm
More informationProduct Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)
Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming) 02Oct08 Rev A 1. SCOPE 1.1. Content This specification, based on IEC 61753-1 Edition 1.0 tests for Category E (Extreme Environment),
More informationProduct Specification CAT 6 UNSHIELDED PATCH CORDS
Product 108-93017 Specification 23/Nov/06 Rev. A CAT 6 UNSHIELDED PATCH CORDS 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for NETCONNECT
More informationJun08 Rev C
Product Specification Connector, Card Edge,.050 Centerline 108-14034 02Jun08 Rev C 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for Tyco Electronics.050 centerline
More informationINTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
INTERNATIONAL TELECOMMUNICATION UNION ITU-T L.36 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (10/98) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
More informationCat 6 Shielded Patch cords
Product Specification 108-93010 14/Oct/2009 Rev E Cat 6 Shielded Patch cords 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for AMP NETCONNECT*
More informationProduct Specification Mono-Shape TM Mark II - 5mm Pitch I.D.C Connectors, For TAB Contacts - RAST5
1. SCOPE 1.1 Content This specification covers performance, test and quality requirements for the Mono-Shape Mark II - 5 mm Pitch I.D.C. Connectors for Tab contacts. These connectors are designed and developed
More informationCat 6 Unshielded Patch cords
Product Specification 108-93017 13/Oct/2009 Rev D Cat 6 Unshielded s 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for AMP NETCONNECT* Cat
More informationETSI TS V1.2.1 ( )
TS 100 783 V1.2.1 (2004-08) Technical Specification Transmission and Multiplexing (TM); Passive optical components; Fibre optic fusion splices for single-mode optical fibre transmission systems for indoor
More informationAPR 17 Rev A
Product Specification 108-130015 11 APR 17 Rev A ChipConnect Cable Assembly 1. SCOPE 1.1. Content This specification covers performance, test and quality requirements for the ChipConnect Cable Assembly
More informationHOUSING ASSY 5 POS. HYBRID STD/JR POWER TIMER TAB & REC.
108-37065 Product Specification Rev. A 18-Jan-2007 Housing Assy 5p Hybrid Std./Jr. Power Timer Tab & Rec. DESIGN OBJECTIVES The product described in this document has not been fully tested to insure conformance
More informationProduct Specification JUL07 Rev. F. 1. Scope : 2. Applicable Documents: 3. Requirements : 1 of Contents. 2.1 AMP Specifications :
1. Scope : 1.1 Contents 11JUL07 Rev. F DDR S.O.DIMM Socket 200 Positions This specification covers the requirements for product performance, test methods and quality assurance provisions of DDR S.O.DIMM
More information17" UNIVERSAL MOUNT INDUSTRIAL MONITOR REVISION E, F & G PRODUCT RELIABILITY TEST REPORT
17" UNIVERSAL MOUNT INDUSTRIAL MONITOR REVISION E, F & G PRODUCT RELIABILITY TEST REPORT Model No. HIS-UM17- _ E, HIS-UM17- _ F and HIS-UM17- _ G Table of Contents Test Report Overview... 3 Testing Rationale...3
More informationETSI TS V1.2.1 ( )
TS 101 263 V1.2.1 (2004-07) Technical Specification Transmission and Multiplexing (TM); Passive optical components; Fibre optic mechanical splices for single-mode optical fibre communications systems for
More information23" PANEL MOUNT INDUSTRIAL MONITOR REVISION C PRODUCT RELIABILITY TEST REPORT
23" PANEL MOUNT INDUSTRIAL MONITOR REVISION C PRODUCT RELIABILITY TEST REPORT Model No. HIS-ML23- _ C Table of Contents Test Report Overview... 3 Testing Rationale...3 Test Plan...4 Test 1 Cold (Steady
More informationITU-T L.404. Field mountable single-mode optical fibre connectors
I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n ITU-T L.404 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (08/2017) SERIES L: ENVIRONMENT AND ICTS, CLIMATE CHANGE, E-WASTE, ENERGY
More informationDraft ES V1.1.1 ( )
Standard Transmission and Multiplexing (TM); Passive optical components; Fibre optic mechanical splices for single-mode optical fibre communications systems; Common requirements and conformance testing
More informationFEB. 17 Rev. A1
Product Specification 108-94552 10 FEB. 17 Rev. A1 The product described in this document has not been fully tested to ensure conformance to the requirements outlined below. Therefore, TE Connectivity
More informationUSB 3.0 Plug & Receptacle
US 3.0 Plug & Receptacle 1. Scope: 1.1 Contents: This specification covers the requirements for product performance, test methods and quality requirements of Tyco Electronics Universal Serial us (US) consortium
More informationSPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES
SPECIFICATION AND PERFORMANCE OF MDP CONNECTOR SERIES CIRCUIT ASSEMBLY CORP. 18 THOMAS STREET, IRVINE, CA 92618-2777 Page No. 1 of 16 CLAUSE CONTENTS PAGE 1.0 SCOPE... 3 2.0 APPLICABLE DOCUMENTS... 3 3.0
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61753-1-3 Edition 1.0 2014-05 Fibre optic interconnecting devices and passive components Performance standard Part 1-3: General and guidance for single-mode fibre optic connector
More informationJun08 Rev A
Product Specification Terminal Block Crimp Snap Plug Assembly 108-2319 09Jun08 Rev A 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the Tyco Electronics
More informationTECHNICAL REPORT Crimp Splice Protection -250M/P150 mark 2
FIBER OPTIC TECHNOLOGY CALIBRATION LABORATORY Document number: TZ_2_7_PP_EN_splice TECHNICAL REPORT Crimp Splice Protection -25M/P15 mark 2 E.G. Tec Ltd. Date: May-1-27 TZ_2_7_EN_splice Contents: 1. General...
More informationLaboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka
Last Amended on 07.10.2015 Page 1 of 18 I. EMC Test Facility 1. Electrical and Electronic Products, Process Control Devices, Lighting Control Products, Sensing and Control Devices, Electromechanical Products,
More informationOCTOBER 4, 2013 C.O.C #213041B VITA 46 VPX CONNECTORS QUALIFICATION TESTING HYPERTRONICS CORPORATION
OCTOBER 4, 2013 C.O.C #213041B VITA 46 VPX CONNECTORS QUALIFICATION TESTING HYPERTRONICS CORPORATION APPROVED BY: THOMAS PEEL PRESIDENT AND DIRECTOR OF TEST PROGRAM DEVELOPMENT CONTECH RESEARCH, INC. ATTLEBORO,
More informationVibration tests on a TNAML Luminaire
Sebert Trillingstechniek B.V. Report M13.001-P13.001 rev.01 Date 26 august 2013 Vibration tests on a TNAML Luminaire Client Technor Benelux B.V. Veersteeg 15 4212 LR Spijk The Netherlands Contact Person
More informationPlug shell and receptacle, single cavity, floating, EN Application of modular rectangular modules and shells per EN4165
PRODUCT SPECIFICATION Sep 22, 29 Rev. B CONNECTOR, SINGLE CAVITY, AEROSPACE, PANEL MOUNT, FLOATING, EN416 1 - SCOPE 1.1. Content This document covers the performances, tests, and quality requirements of
More informationUniversal Connectivity Platform
Enabling Business Transformation through Agility Availability Efficiency UCP provides a fully modular approach to accommodate both copper and fiber into one common footprint, simplifying network architecture
More informationENVIRONMENTAL TEST REPORT
MECHANICAL TESTING 0839.04 Hermon Laboratories Ltd. Harakevet Industrial Zone, Binyamina 30500, Israel Tel. +972-4-6288001 Fax. +972-4-6288277 E-mail: mail@hermonlabs.com ENVIRONMENTAL TEST REPORT ACCORDING
More informationMichael J. Caron, Test Engineer. Lee R. Senne, Test Technician. Kent L. Erickson, Dynamics Division Manager
Engineering Report 49820-1 Vibration Test for Crystal Group Inc. Prepared by Michael J. Caron, Test Engineer Lee R. Senne, Test Technician Approved by Kent L. Erickson, Dynamics Division Manager This document
More informationMODULAR CONNECTOR 154 (58 AND 96) POS, WATERPROOF PRODUCT SPECIFICATION
MODULAR 154 (58 AND 96) POS, WATERPROOF PRODUCT SPECIFICATION 108-18965 Product Specification 108-18965 10.02. 2011 Rev C1 MODULAR 154 (58 AND 96) POSITION, WATERPROOF CONTENT : 1 PRODUCT OVERVIEW 1.1
More informationTest Report for Senko Advanced Components, Report No RES3005 February 22, Test Report. Senko Advanced Components
Test Report Report No. Client: Address: RES3005 Senko Advanced Components 225 Cedar Hill Street Marlboro, MA 01752 Phone: 508-481-9999 Product Tested: Q-XP MSOC 900m Test Dates: April 2010 October 2010
More informationFT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series
FT702LT Turbine control wind sensor......gives durability a new meaning FT702LT series Proven High Availability The FT702LT ultrasonic anemometer is the result of FT Technologies 10 years of experience
More informationCOMITÉ EUROPÉEN DES ASSURANCES
COMITÉ EUROPÉEN DES ASSURANCES SECRETARIAT GENERAL 3bis, rue de la Chaussée d'antin F 75009 Paris Tél. : +33 1 44 83 11 73 Fax : +33 1 44 83 11 85 Web : cea.assur.org DELEGATION A BRUXELLES Square de Meeûs,
More informationReport No 288/ Part 1 of 2 This report consists of 22 pages. Maxitone ZAMT Type A Addressable Sounder. See Assessment Summary for details
Test Report Report No 288/7387780 Part 1 of 2 This report consists of 22 pages Licence/Certificate No KM 532936 Client GLT Exports Limited 72-78 Morfa Road Hafod Swansea SA1 2EN United Kingdom Authority
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 NATIONAL TECHNICAL SYSTEMS (NTS) 1536 East Valencia Drive Fullerton, California 92831 Cathy Rumble Phone: (714) 879-6110 E-mail: cathy.rumble@nts.com Website:
More informationProduct Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616
TO WHOM IT MAY CONCERN Product Test report Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616 Product name: BOSCH FLEXIDOME IP indoor 4000 HD/IR BOSCH FLEXIDOME IP indoor
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Washington Laboratories, Ltd. 7560 Lindbergh
More informationProcedure for the Approval of New Fire Detection and Alarm Technologies
VdS Guidelines for Automatic Fire Detection and Fire Alarm Systems VdS 3469en Procedure for the Approval of New Fire Detection and Alarm Technologies VdS 3469en : 2016-01 (01) Publisher and publishing
More informationM7100 Pressure Transducer
SPECIFICATIONS Performance standard on and off highway engine and vehicle OEMs Rugged for heavy equipment and outdoor use Designed specifically for high volume applications Stainless steel wetted surfaces
More informationEngineering Report Vibration Test for Intertek Testing Services Prepared by Approved by 9725 Girard Avenue South Minneapolis, MN 55431
Engineering Report 47566-1 Vibration Test for Intertek Testing Services Prepared by Michael J. Caron, Test Engineer Lee R. Senne, Test Technician Approved by Kent L. Erickson, Dynamics Division Manager
More informationEnvironment Test Report
Environment Test Report Product Name: Product Model: Product Type: Power System TP48200A TP48200A-H15A3 TP48200A-H15A5 TP48200A-D15A1 Report Number: SYBH(H) 346052012 Reliability Laboratory of Huawei Technologies
More informationHMN-D2 Insert Series
HMN-D2 Insert Series Table of contents 1. SCOPE... 2 1.1. Content... 2 1.2. Qualification... 2 2. APPLICABLE DOCUMENTS... 2 2.1. TE Connectivity Documents... 2 2.2. Other Documents... 2 3. REQUIREMENTS...
More informationFibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC. Philip C Longhurst Corporate Fibre Optic R & D Manager
Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC Philip C Longhurst Corporate Fibre Optic R & D Manager Outline CENELEC TC86BXA work programme IEC SC86B WG 6 and
More informationCNBOP-PIB Standard Fire Protection
Centrum Naukowo Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego Państwowy Instytut Badawczy CNBOP-PIB-BA-01E:2014 Revision 1, February 2014 CNBOP-PIB Standard Fire Protection Laboratory Tests
More informationTechnical Specification for the Mastic-Sealed Fiber-Optic Closure System (FOSC 300C)
Page 1 of 24 Prepared by: Chris Radelet R&D Department Manager Approved by: Pieter De Coster Product Manager for the Mastic-Sealed Fiber-Optic Closure System (FOSC 300C) The FOSC 300C closure system is
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61300-2-1 Second edition 2003-01 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-1: Tests Vibration (sinusoidal) Dispositifs
More informationDSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor
DSF xx15.xx xhv Ex-Atex Product ID Type # Product # Drawing # DSF 1215.01 SHV Ex-atex (5m) 304Z-05197 113216 DSF 1415.01 AHV Ex-atex S148 304Z-05256 113351 DSF 1615.01 SHV Ex-atex (5m) 304Z-05196 113214
More informationUniversal Connectivity Platform A Modular Approach to Infrastructure Design
A Modular Approach to Infrastructure Design TE Connectivity s Universal Connectivity Platform (UCP) provides a fully modular approach to designing data centers and telecommunications rooms. This patch
More informationNG4access ODF Platform Standard Chassis Installation Manual
NG4access ODF Platform Standard Chassis Installation Manual TECP-90-703 Issue 1 8/2012 24939-A Content Page INTRODUCTION...1 1 PRODUCT DESCRIPTION...2 2 MAIN COMPONENTS...3 3 GROUNDING AND BONDING THE
More informationProduct Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616
TO WHOM IT MAY CONCERN Product Test report Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616 Product name: BOSCH FLEXIDOME IP outdoor 4000 HD/IR BOSCH FLEXIDOME IP outdoor
More informationTechnical Specification for the Gel-Sealed Fiber-Optic Closure System (FOSC 450)
Page 1 of 26 Prepared by: Daniel Daems R&D Department Manager Approved by: P. De Coster Product Manager for the Gel-Sealed Fiber-Optic Closure System (FOSC 450) The FOSC 450 system is a fully mechanical
More informationDSS SERIES. Single Channel Hall Effect Speed Sensor. Product ID
Product ID Type # Product # Drawing # 378Z-05380 DSS 1210.00 STV (5m) 113807 374Z-04996 DSS 1210.02 PHV 112705 374Z-05052 DSS 1210.02 SHV (2m) 112865 378Z-05864 DSS 1210.12 AHV 115675 378Z-05910 DSS 1210.13
More informationMX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA
MX1A and MX1B: Laser Displacement Detection MX1A and MX1B: Laser Displacement Detection Built-in math capabilities available (MX1B only) Digital display on amplifier; easy setting and monitoring (MX1B
More informationDSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor
Product ID Type # Product # Drawing # DSF 1210.00 SHV Ex-atex (2m) 374Z-05066 110428F1 DSF 1210.00 SHV Ex-atex (5m) 374Z-05176 110428F1 DSF 1210.00 SHV Ex-atex (10m) 374Z-05590 110428F1 DSF 1410.00 SHV
More informationTB/T Translated English of Chinese Standard: TB/T RAILWAY INDUSTRY STANDARD
Translated English of Chinese Standard: TB/T2296-2011 www.chinesestandard.net Sales@ChineseStandard.net RAILWAY INDUSTRY STANDARD TB OF THE PEOPLE S REPUBLIC OF CHINA ICS 45.020 S 60 TB/T 2296-2011 Replacing
More informationQuality Assurance and Quality Control of Optical Fibres for CERN
EN Seminar - Quality Assurance and Quality Control of Optical Fibres for CERN Elisa GUILLERMAIN and Johannes TROLLER on behalf of the Cabling and Optical Fibre Section (EN-EL-CF) Seminar Outline 2 Johannes
More informationVTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links
VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links TB Number 004 This bulletin is supplied for information only and is intended to provide
More informationRules for Classification and Construction Additional Rules and Guidelines
VI Rules for Classification and Construction Additional Rules and Guidelines 7 Guidelines for the Performance of Type Approvals 7 Test Requirements for Statical Converters with Semi-Conductors Edition
More information2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK
PART 1 GENERAL 1.01 SCOPE OF WORK SECTION 27 12 23 FIBER OPTIC DATA NETWORK A. Furnish, install, terminate, and test all fiber optic equipment and cabling necessary for a complete and functional data highway
More informationTEMPORARY IMMERSION AND DUST TEST REPORT
Report No. :HS1007140060A Version:A TEMPORARY IMMERSION AND DUST TEST REPORT Company :Gold Apollo Co., Ltd Address :3F.-1, No.77, Sec. 1, Xintai 5th Rd., Xizhi City, Taipei County 221, Taiwan (R.O.C.)
More informationApplications Engineering Notes
Applications Engineering Notes Document Title Document Number Revision Number Product Specification and Qualification Test Report: IBC Brand Fiber Optic Connector Cleaner MT38 II AEN-1146 Issue Effective
More informationCERTIFICATE of QUALITY TEST
Testing laboratory for climatic, mechanical and corrosive environmental stress CERTIFICATE of QUALITY TEST Test report - No. 10142 / 13 Client ADDI-DATA GmbH Airpark Business Center Airport Boulevard B210
More informationFiber Optic Connector Cleaning and Inspection Kit Instructions
Instruction Sheet 860376037 Rev E, March 2018 Fiber Optic Connector Cleaning and Inspection Kit Instructions General This instruction sheet describes the use of the CommScope Fiber Optic Connector Cleaning
More informationVictoreen & 660-8
Victoreen 660-6 500-100 6000-100 660-7 & 660-8 CT Probes and Phantoms Operators Manual March 2005 Manual No. 660-6-1 Rev. 3 2004, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A. All product
More informationWLAC Facilities Committee Meeting. May 15, 2017
Campus Program Report WLAC Facilities Committee Meeting May 15, 2017 Page 1 DSA completed the initial review June 24, 2016 and the Design Builder is proceeding through the back check process. DSA reports
More informationProduct Tests Report
TO WHOM IT MAY CONCERN Page: 1 of 5 Product name: Model number and description: MIC IP starlight 7000i Product Tests Report MIC-7502-Z30B, PTZ camera 2MP HDR 30x IP68 IK10, black MIC-7502-Z30W, PTZ camera
More informationFiber Optic Distribution Cables (6-144 Fibers)
900um Buffered Aramid Yarn Strength Members Outer 6 or 12 Subunit Central Strength Member Outer Ripcord Single Unit Cable 6-24 Multi-Unit Cable 24-144 Description: AMP NETCONNECT distribution cables are
More informationISO/TS TECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION ISO/TS 10811-1 First edition 2000-06-01 Mechanical vibration and shock Vibration and shock in buildings with sensitive equipment Part 1: Measurement and evaluation Vibrations et
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 62341-5-2 Edition 2.0 2019-03 colour inside Organic light emitting diode (OLED) displays Part 5-2: Mechanical endurance test methods INTERNATIONAL ELECTROTECHNICAL COMMISSION
More informationMore Precision. indusensor // Linear inductive displacement sensors
More Precision indusensor // Linear inductive displacement sensors 18 Long-stroke sensors for hydraulics & pneumatics indusensor EDS - Measurement ranges 75... 630mm - Linearity ±0.3% FSO - Integrated
More informationWLAC Facilities Committee Meeting. September 18, 2017
Campus Program Report WLAC Facilities Committee Meeting September 18, 2017 Page 1 DSA approved the plans on May 15, 2017. Notice to Proceed was issued June 8, 2017 and the project remains on schedule for
More informationIEC Type Test Report Report No. EU1515-H-00.3 Type PVI-LP Polymer Arrester 10,000 A Line Discharge Class 2
IEC Type Test Report Report No. EU1515-H-00.3 Type PVI-LP Polymer Arrester 10,000 A Line Discharge Class 2 This report records the results of this type test made on 10 ka Class 2 arresters rated 3 thru
More informationFiber Optic Patch Cord and Pigtails
Fiber Optic Patch Cord and Pigtails Description The optical fiber patch cords are fitted at both ends with same connector types or different connector types. Our fiber optic patch cords are ultra reliable
More informationANSI-ASQ National Accreditation Board/ACLASS
ANSI-ASQ National Accreditation Board/ACLASS SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Washington Laboratories, Ltd. 1, 2 7560 Lindbergh Drive, Gaithersburg, Maryland 20879 John Repella Phone: 301-216-1500
More informationEnglish version. Central Secretariat: rue de Stassart 35, B Brussels
TECHNICAL REPORT CLC/TR 50378-2-1 RAPPORT TECHNIQUE TECHNISCHER BERICHT December 2008 ICS 33.180.20 English version Passive components to be used in optical fibre communication systems - Product specifications
More informationMore Precision. indusensor // Linear inductive displacement sensors
More Precision indusensor // Linear inductive displacement sensors 14 Long-stroke sensors for hydraulics & pneumatics indusensor EDS - Measurement ranges 75... 630mm - Linearity ±0.3% FSO - Integrated
More informationECP OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS
Network(s): Summary: ENGINEERING COMMISSIONING PROCEDURE ECP 11-0009 OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS EPN, LPN, SPN This standard details the requirements for the splicing,
More informationThis is a preview - click here to buy the full publication ICS ISBN
IEC 62341-5-2 Edition 2.0 2019-03 REDLINE VERSION colour inside Organic light emitting diode (OLED) displays Part 5-2: Mechanical endurance testing methods INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS
More informationICS Regent. Fire Detector Input Modules PD-6032 (T3419)
ICS Regent Fire Detector Input Modules (T3419) Issue 1, March, 06 Fire detector input modules provide interfaces for 16 fire detector inputs such as smoke detectors, flame detectors, temperature detectors,
More informationThe advantages of using waveguides in Hi-Fi loudspeakers
The advantages of using waveguides in Hi-Fi loudspeakers Ole Lund Christensen, B.Sc.E.E Amphion Loudspeakers Ltd, Finland The advantages of using waveguides in Hi-Fi loudspeakers By Ole Lund Christensen,
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61051-1 QC 420000 Second edition 2007-04 Varistors for use in electronic equipment Part 1: Generic specification Commission Electrotechnique Internationale International Electrotechnical
More informationSpecial Provision No. 683S28 December 2017
FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE - Item No. FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE (TEMPORARY) - Item No. Special Provision No. 683S28 December 2017 1. SCOPE
More information