Gas Detection System TOX ALARM DG2000-Garage

Size: px
Start display at page:

Download "Gas Detection System TOX ALARM DG2000-Garage"

Transcription

1 Gas Detection System TOX ALARM DG2000-Garage Gas Detection System 32 independent programmable channels 2 programmable alarm levels for each gas = up to 6 for each channel LCD alphanumeric display of gas concentration + precise clock Audible (integrated buzzer) and visual alarm Non-volatile memory for past alarm events 3 SPDT 5A/250 V output relays RS485 (Modbus RTU ), galvanic isolated Sophisticated Sensor I. APPLICATION The Gas Detection System TOX ALARM DG2000-Garage is purposed for detection and control of dangerous concentrations of carbon monoxide (CO), methane (CH4) and propane-butane (LPG) (all 3 or any combination of them). It is applicable in underground garages, tunnels, automobile workshops and engine testing stands, metallurgy & chemical industry factories and other areas, where toxic CO concentrations can be found. To the main control unit TOX ALARM DG2000-Garage can be connected up to 32 sophisticated sensors, mounted in the hazardous areas, which need to be monitored and controlled. The sophisticated sensors are from the series DG510/3G and have a standard range of 0-300ppm CO (up to 1000ppm on request), 0-50% LEL (lower explosion limit) of LPG and CH4. The communication is maintained through serial interface RS485. There are two programmable via the keypad alarm levels for each detected kind of gas pre-alarm AL1 and alarm AL2 connected with 2 integrated SPDT 5A/250V output relays. The two relays are common for all channels. If any detected gas concentration reaches pre-alarm level AL1 and does not decrease under it for a certain period of time (0 999,9 min, adjustable via the keypad), an integrated buzzer starts emitting repeated short beeps, the LED AL1 is lighted up and the output relay AL1 is activated. The relay output may operate a ventilation system in order to clear the air in the dangerous area, any kind of alarm systems, etc. If despite the ventilation the gas concentration exceeds the set alarm level, immediately the buzzer starts emitting a continuous signal, the LED AL2 is lighted up and AL2 output relay is activated, which can operate a stronger ventilation system, a siren, a semaphore system, barriers, alarm lights or other systems to restrict the access of people to the dangerous area until the concentration drops below the alarm level. The Gas Detection System has a non-volatile memory capacity of 30 alarm events. The alphanumeric LCD indicates the 3 different process values of gas concentration of every channel on rotational basis. The user can manually fix the indication to any desired channel. In case of a sensor or cable fault a common for all channels SPDT output relay is activated, LED FLT is lighted up and the audible alarm is activated. DELTA INSTRUMENTS Ltd. 23 A. Saharov blvd., Mladost 1, 1784 Sofia, Bulgaria Tel , , ; Fax: Web Site: delta@deltainst.com

2 II. TECHNICAL SPECIFICATIONS Power supply for control unit 230 V, 50 Hz Power supply for sensors 230 V, 50 Hz Detected Gas Carbon Monoxide (CO), Propane-Butane (LPG), Methane (CH4) Range ppm CO (up to 1000 ppm on request), 0-50% LPG, 0-50% CH4 Pre-alarm level output signal AL1 5A/250V SPDT relay common for all channels Alarm level output signal AL2 5A/250V SPDT relay common for all channels Sensor or cable fault output signal 5A/250V SPDT relay common for all channels Signalization Audible (integrated buzzer) and visual (LEDs) Display LCD, alphanumeric Communication interface with the sensors RS485 Recommended cable type for the RS485 LiYCY 1x2x0.5 (a shielded twisted pair, Ø 0.5 mm 2 ) network between sensors Communication interface to a PC or a RS485 (Modbus RTU), galvanic isolated monitoring & control system Dimensions of control unit 160 x 166 x 102 mm /wall mountable/ Dimensions of a sophisticated sensor 115 x 100 x 40 mm Protection degree of control unit IP65 Protection degree of sensors IP30 Ambient temperature for control unit 0 50 С Ambient temperature for sensors С III. NETWORK SCHEME BMS RS485 (Modbus/RTU) Stations RS485 RS485 RS485 Sensors 2

3 The communication interface between sensors and main control unit is RS485. The following scheme illustrates the topology of such RS485 network. At the one end of the network is placed the main control unit, which has an integrated terminating resistor. Identical terminating resistor should be mounted at the last device of the network as well. The connection cable of each sensor to the main communication cable should not be longer than 2-3 meters. The communication between main control unit and sensors is maintained at the low baud rate of 9600, so it can cover a greater length of up to m. RS485 comp. IV. CONNECTION SCHEME 12V AL 1 AL 2 FLT 220V A B GND A RS485 sen sors B GND +VD _ + L N DESCRIPTION OF TERMINALS Terminal Nr. Description 1,2,3 Galvanic isolated RS485 (Modbus/RTU Slave) for connection with SCADA/HMI. Terminal 1 is +, terminal 2 is -. Terminal 3 is galvanic isolated ground. 4,5 RS485 for communication with sensors. Terminal 4 is +, Terminal 5 is -. 8,9 Back-up power supply accumulator 12VDC. Terminal 8 is +, terminal 9 is - 10,11,12 SPDT relay for pre-alarm level. Terminals 11, 12 are normally open. 13,14,15 SPDT relay for alarm level. Terminals 14, 15 are normally open. 16,17,18 SPDT relay for cable or sensor fault, Terminals 17, 18 are normally open. 19,20,21 Main power supply. Term. 19 phase, Term. 20 zero, Term ground 3

4 Connection of sensors to main control unit CONTROL UNIT A B SENSOR A B SENSOR A B V. MOUNTING INSTRUCTIONS Mount the Gas Detection System on the wall in an area with normal risk of fire. VI. GENERAL CONDITIONS 6.1. TOX ALARM DG2000-Garage may be used only in applications, approved by its manufacturer - DELTA INSTRUMENTS Ltd Test and calibration have to be made every 12 months. The test overall performance will be ensured in a best way through a periodical maintenance servicing contract with the manufacturer The safe operation guarantee is not valid, if the device is maintained with unauthorized personnel or if the corresponding to the term of question Test and Calibration Report is not available If no other parameters are specified, the device is calibrated by the manufacturer with values 50 and 100 ppm CO, 10% and 20% LEL of CH4 and LPG accordingly for pre-alarm and alarm levels and by correct mounting no additional settings should be necessary. VII. OPERATION MODES OF TOX ALARM DG2000-Garage Standard operation mode After switching on the power supply of the main control unit, it enters a standard operation mode of displaying the measured 3 different gas concentration values for each channel on an automatic rotation basis. The upper row of the display indicates Ch CH4 LPG CO and the lower row respectively shows the number of the currently displayed channel, the concentration of methane, propane-butane and carbon monoxide. If any measured value in the lower row blinks, the pre-alarm level AL1 is activated. If the indications of the upper row blink as well, means that the alarm level AL2 is activated too. 4

5 The lower row can display also the following notifications: Offline No response from the sensor Actv The sensor is in activation process (warming up) Fault Sensor s measurement error Not update the control unit has not sent yet a request to the sensor Clock function By pressing the key MODE once while in standard operation mode, the display indicates the real time upper row: hh:mm:ss and lower row date (dd.mm.yy) Manual channel switching mode By pressing the key MODE once again (second time) the display enters a mode for manual switching of all channels. In this mode the operator can go through every channel manually by pressing the and keys. Mode of displaying past alarm events By pressing the key MODE once again (third time) the display enters a mode for visualization of the archive with past alarm events. After entering this mode is displayed the last registered alarm event. The operator can go through all 30 stored past alarms by pressing the and keys. By pressing the key MODE once again (fourth time) the display enters back the standard operation mode. Deactivation of the sound alarm In case of any activated alarm event the sound alarm (buzzer) is triggered as well. It can be deactivated by holding pressed the key ENT. VII. ENTERING PARAMETERS The 32-Channel Gas Detector provides an option for the customer to set for each channel different gas concentration percentage values for the pre-alarm and alarm levels of each type of gas, observing the restrictions 0 AL1 AL2 50 % LEL of CH4 and LPG and 0 AL1 AL2 300ppm for CO. The menu for programming gas detector s parameters is entered from the standard operation mode by pressing and holding the button MODE. It is separated in several submenus, listed in the table below. Traversing the elements of the menu or a submenu is operated by the vertical arrow keys: and. By pressing the button ENT, entering a correct corresponding password and hitting ENT again, the operator can enter a submenu. To exit a submenu, the operator can press MODE. For editing the different parameters of a submenu are used all arrow keys,, and. A newly edited value of any parameter should be saved (confirmed) by pressing the ENT button. 5

6 Indication Submenu s content Password Date Time Submenu for setting the clock (date and time) Alarms Adjusting the pre-alarm and alarm levels of each channel On/Off Ch Activation/ Deactivation of each channel RS-485 Params Modbus RS-485 parameters Others - enabling/disabling the audible alarm setting the reaction delay of AL1 output relay Factory Sett. Parameters, accessible only by manufacturer The accessible for adjusting parameters are listed in the following table: Date Time - Submenu for setting the clock of the control unit Date E Date setting in the form: dd.mm.yyyy Time E Time setting in the form: hh:mm:sec Alarms - Adjusting the pre-alarm and alarm levels of each channel LL CH4 Pre-alarm level of methane in % LL LPG Pre-alarm level of propane-butane in % LL CO Pre-alarm level of carbon monoxide (CO) in ppm HL CH4 Alarm level of methane in % HL LPG Alarm level of propane-butane in % HL CO Alarm level of carbon monoxide (СО) in ppm On/Off Channels Activation / Deactivation of each channel Channel 1 Activation / Deactivation of channel 1 Channel 2 Activation / Deactivation of channel Channel 32 Activation / Deactivation of channel 32 RS-485 Params - Modbus RS-485 Parameters Device Addr Address of the device Baud rate Baud Rate Others On/Off Siren Enabling / Disabling the Audible Alarm AL1 Delay sec Reaction Delay of the Pre-alarm Output Relay in seconds 6

7 APPENDIX А DESCRIPTION OF MODBUS COMMUNICATION PROTOCOL 1. The device conforms to a subset of the MODBUS over Serial Line (RS 485) specification V 1.0. Only RTU transmission mode of characters is supported. For detailed information about the Modbus protocol visit 2. The device utilizes the following configuration: Baudrate = "1200","2400","4800","9600","14400" Databits = 8 Parity = none Stopbit = 1 3. Connection scheme: It is required to place Line termination resistors (LT) near each of the ends of the bus with typical value of 360 Ohms (0.5W resistor). There is an integrated LT resistor in the main gas detection unit DG2000, so there needs to be placed only 1 more at the other end of the bus. 7

8 4. Input Registers (Read Only): Address Description Two 16-bit registers, indicating if the corresponding channel is activated or deactivated. The least significant bits of both registers correspond respectively to channels 1 and 17. The most significant bits channels 16 and 32. Set bit (=1) = activated channel. Two 16-bit registers, indicating if there is received data from the sensor. When DG2000 is turned on, it starts reading measured data from each sensor. Set bit (=1) means that the sensor has been initially read. The least significant bits of both registers correspond respectively to channels 1 and 17. The most significant bits channels 16 and 32. Two 16-bit registers, indicating if a sensor is Offline (does not respond). The least significant bits of both registers correspond respectively to channels 1 and 17. The most significant bits channels 16 and 32. Set bit (=1) means that the sensor is offline. Two 16-bit registers, indicating if there is an error by the measurement of methane (e.g. disconnected sensor). The least significant bits of both registers correspond respectively to channels 1 and 17. The most significant bits channels 16 and 32. Set bit (=1) means that there is an error. Two 16-bit registers, indicating if there is an error by the measurement of propane-butane (e.g. disconnected sensor). The least significant bits of both registers correspond respectively to channels 1 and 17. The most significant bits channels 16 and 32. Set bit (=1) means that there is an error. Two 16-bit registers, indicating if there is an error by the measurement of carbon monoxide (CO) (e.g. disconnected sensor). The least significant bits of both registers correspond respectively to channels 1 and 17. The most significant bits channels 16 and 32. Set bit (=1) means that there is an error. Right after connecting DG2000 to the power supply, the sensors undergo an activation (warming up) process for about 30 sec. The values, measured by sensors during their activation process should not be considered real. So if a sensor is warming up, the corresponding bit will be set (=1). The least significant bits of both registers correspond respectively to channels 1 and 17. The most significant bits channels 16 and 32. These 16-bit registers indicate if a channel s pre-alarm level is activated. The least significant bits of both registers correspond respectively to channels 1 and 17. The most significant bits channels 16 and 32. Set bit (=1) = activated pre-alarm level. These 16-bit registers indicate if a channel s alarm level is activated. The least significant bits of both registers correspond respectively to channels 1 and 17. The most significant bits channels 16 and 32. Set bit (=1) = activated alarm level. Pre-alarm level for СН4 Alarm level for СН4 Pre-alarm level for LPG Alarm level for LPG Pre-alarm level for СO Alarm level for СO 8

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

REPEATER FS5200R INSTRUCTION MANUAL

REPEATER FS5200R INSTRUCTION MANUAL REPEATER FS5200R INSTRUCTION MANUAL Instruction Manual Page1 CONTENTS 1. Introduction... 3 2. Function... 3 3. Technical data... 3 4. Contents of delivery... 4 5. General information... 5 6. Duty Mode...

More information

SCAN200E USER S MANUAL

SCAN200E USER S MANUAL SCAN200E USER S MANUAL Code No. 2071 1052 rev. 1.4 Code No. 2071 1052 Rev. 1.4 Page 2/16 SCAN200E User s Manual Foreword This manual is for SCAN200E Controller running software version 2.03 or later. We

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6 Digital Gas Transmitters with Auxiliary s & Control Specifications subject to change without notice. USA 181011 Page 1 of 5 DESCRIPTION Digital RS-485 communicating, addressable toxic and combustible gas

More information

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro A d e v i h c r D c o n e m u WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free from defects in workmanship

More information

RS 0021 DIGITAL GAS DETECTION CONTROL UNIT FOR SENSORS WITH S-BUS PROTOCOL. USER MANUAL Read carefully before use

RS 0021 DIGITAL GAS DETECTION CONTROL UNIT FOR SENSORS WITH S-BUS PROTOCOL. USER MANUAL Read carefully before use RS 0021 DIGITAL GAS DETECTION CONTROL UNIT FOR SENSORS WITH S-BUS PROTOCOL USER MANUAL Read carefully before use GENERAL INFORMATION This device is a gas control unit with RS485 serial communication, based

More information

DIGITAL TEMPERATURE RELAY TR-100

DIGITAL TEMPERATURE RELAY TR-100 LTD Research-and-Manufacture Company DIGITAL TEMPERATURE RELAY USER S MANUAL www.novatek-electro.com - 2 - Service manual is intended for getting acquaints with hardware, operation principals, modes of

More information

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option SM3000 Videographic Recorder User Guide (RTU) Communications Option ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow

More information

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1- DPR-45 User Manual V-2.0 (2..206) DPR-45 TEMPERATURE PROTECTION RELAY PT00 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT 9-50VDC SUPPLY DESCRIPTION DPR-45 is a precision unit designed for the temperature

More information

Warranty Registration

Warranty Registration WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free from defects in workmanship and materials for a period

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

Toxic and Explosive Smart Gas Monitor PN / Installation and User Manual

Toxic and Explosive Smart Gas Monitor PN / Installation and User Manual Toxic and Explosive Smart Gas Monitor PN 151022/151023 Installation and User Manual Quest Controls, Inc. 208 9 th Street Dr. West Palmetto, FL 34221 www.questcontrols.com Phone: (941) 729-4799 Fax: (941)

More information

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual BS-316 Gas detection control panel up to 16 inputs Installation operation manual Page 1 from 21 Contents 1 Operation instructions--------------------------------------------------------------------------------------------------------------------3

More information

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS.  A4741 / Rev.1 DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS User Manual and Menu Map A4741 / Rev.1 www.entes.com.tr ATTENTION -Disconnect all power before connecting the device. -Don t remove

More information

Model D12-IR. Digital Gas Transmitter...

Model D12-IR. Digital Gas Transmitter... Model D12-IR Digital Gas Transmitter... ATI s Series D12 gas transmitter line now includes a versatile Infrared system that can be configured for LEL or select toxic gases. The D12-IR utilizes a compact

More information

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device Safety Instructions Used symbols Important Comments Before starting with installation of the MS 10B Alarm Unit, we recommend you to read the important information beneath. Qualification The installation

More information

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM 2 Line, 16 Characters/row LCD Display Temperature Input Range -50 C to +500 C -58 F to + 932 F Enclosure NEMA Type 4X Current Rating 30A max (resistive load only) Ambient Temperature -40 C to + 40 C -40

More information

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: / Planungsbüro + Service: Esteraustr. 10, 56379 Holzappel Tel.: 0 64 39 / 90 19 90 Fax.: 0 64 39 / 90 19 91 E-Mail: u.ramakers@umsitec.de Entwicklung + Fertigung + Service: Heerweg 15 D, 73770 Denkendorf

More information

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head 4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head NET DRAFT version 2.1-2008 Pag. 1 4-20mA Cyber - DRAFT version 2.1-2008 Pag.

More information

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays

More information

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min

More information

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Process & TeMPerATUre UniversAl input DigiTAl MeTers Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min

More information

Warranty Registration

Warranty Registration WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free from defects in workmanship and materials for a period

More information

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number Worldwide Supplier of Safety Solutions GfG Instrumentation 1194 Oak Valley Drive #20 Phone: 734-769-0573 Fax: 734-769-1888 E-Mail: info@gfg-inc.com Internet: www.gfg-inc.com GMA 301 Operation Manual Part

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

Danfoss gas detection unit Type GD Heavy Duty

Danfoss gas detection unit Type GD Heavy Duty Data sheet Danfoss gas detection unit Type GD Heavy Duty The Heavy Duty gas detection units are used for monitoring and warning of hazardous Ammonia gas concentrations. They are intended for ATEX/ IECEx

More information

Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer

Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer ABB MEASUREMENT & ANALYTICS OPERATING INSTRUCTION SUPPLEMENT COM/AZ40/MOD-EN REV. A Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer Communications supplement Measurement made easy Oxygen

More information

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features. CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse

More information

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Revision 6/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...

More information

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528]

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528] Installation- & Operation manual [Dok. id: mi-303gb_180528] Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction and control output MF-PFA ver 3.x NOTE! Read through the entire manual

More information

MODEL 4300-PG CENTRAL ACCESS PANEL FOR EC-GOLD TRANSMITTERS. User Manual

MODEL 4300-PG CENTRAL ACCESS PANEL FOR EC-GOLD TRANSMITTERS. User Manual MODEL 4300-PG CENTRAL ACCESS PANEL FOR EC-GOLD TRANSMITTERS User Manual Technical Support Continental North America Toll Free 1-(800) 387-9487 Ph: +1 (905) 829-2418 Fx: +1 (905) 829-4701 A Product of Arjay

More information

EasyTronic III MANUAL SERVICE

EasyTronic III MANUAL SERVICE rev.6 EasyTronic III MANUAL SERVICE General characteristics: Power supply 24 Vac ±15% Max consumption at 24Vac 300mA Relay outputs 6 Maximum relay current 8 A res. Serial standard RS232 2 Serial standard

More information

21-light Remote Annunciator. Owner s Manual

21-light Remote Annunciator. Owner s Manual 21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With

More information

CONVENTIONAL FIRE CONTROL PANELS FS 5100 and FS 5200

CONVENTIONAL FIRE CONTROL PANELS FS 5100 and FS 5200 CONVENTIONAL FIRE CONTROL PANELS FS 500 and FS 500 BASIC FEATURES Fire Control Panels FS 500 and FS 500 are up-to-date, highly reliable, multifunctional and versatile units, providing the user with unexpected

More information

Fire control panels FC360

Fire control panels FC360 Cerberus TM FIT Fire control panels FC360 FC361-ZZ, FC361-ZA, FC361-YZ, FC361-YA Fire control panels (1-loop) for addressable peripheral devices with integrated operating unit One loop with 126 addresses

More information

Multi-Gas-Controller MGC2

Multi-Gas-Controller MGC2 Page 1 Aug. 2018 Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology for continuous monitoring of the ambient air to detect toxic and combustible gases, refrigerants

More information

CTT8 TEMPERATURE MONITOR DEVICE

CTT8 TEMPERATURE MONITOR DEVICE INSTRUCTION MANUAL IM302-U v2.3 CTT8 TEMPERATURE MONITOR DEVICE GENERALITY The device of control temperatures CTT8 is used in the control of electric machine, transformer, motor, etc. where it s possible

More information

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System Nitrogen Dioxide (NO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in nitrogen dioxide (NO)/diesel fume gas sensor, accepts one analog remote device such as a secondary

More information

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation Gas Detection Control Panel Analog and digital controller 4 or 8 lines / 6 to detectors max Highly versatile controller Cost savings on wiring installation Certifications The The Fixed Fixed Gas Gas Detection

More information

MO n : 12JMC rév A

MO n : 12JMC rév A CTT8 MO n : rév A Page 2 / 18 MODIFICATIONS Rev. Description Date Checked by Approuved by Z Creation 2012/02/12 JMC LA A First issue 2012/02/14 JMC LA INDEX Page 3 / 18 GENERALITY 4 INTRODUCTION 4 ACCESSORIES

More information

Macurco DVP-120 / DVP-120M Detection and Ventilation Control Panel User Instructions

Macurco DVP-120 / DVP-120M Detection and Ventilation Control Panel User Instructions Macurco DVP-120 / DVP-120M Detection and Ventilation Control Panel User Instructions IMPORTANT: Keep these User Instructions for reference. TABLE OF CONTENTS 1 Introduction 4 1.1 DVP-120 General Information

More information

Inc Series Digital Gas Detector/Controller. Operation Manual

Inc Series Digital Gas Detector/Controller. Operation Manual 5 Series Digital Gas Detector/Controller Operation Manual TABLE OF CONTENTS 1. 2. 3. 4. 5. 6. 7. General Description 1.1 Applications 1.2 Features Model Selection Guide Characteristics Installation 4.1

More information

BX444-Mc Gas Detector

BX444-Mc Gas Detector Installation and User Guide Rev.01. BX444-Mc Gas Detector Application Duomo is recognised within the gas industry for providing a comprehensive range of low cost, high reliability gas detection for many

More information

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual Revision 4/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...

More information

GAS PLUS ALARM SYSTEM

GAS PLUS ALARM SYSTEM GAS PLUS -IR SERIES 4688-IR COMBUSTIBLE GAS OR CARBON DIOXIDE TRANSMITTER GAS PLUS -IR TRANSMITTER SERIES 4688-IR COMBUSTIBLE GAS OR CARBON DIOXIDE TRANSMITTER The Scott Gas Plus -IR Model 4688 IR Gas

More information

FLOW CONTROLLER TYPE S/601

FLOW CONTROLLER TYPE S/601 Checked Version Release date QA V4.2.6 F1 F2 EN 26.01.2012 Manual FLOW CONTROL FLOW CONTROLLER TYPE S/601 MODELS F1 AND F2 INTRODUCTION Thank you for using the S/601 flow and batch control series. This

More information

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output Features Electrochemical sensor element (0)2-10 Vdc or (0)4-20 ma output, jumper selectable Standard IP65 plastic enclosure Measuring ranges 0-50 ppm 0-100 ppm 0-150 ppm 0-200 ppm 0-250 ppm 0-300 ppm 0-500

More information

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers. ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page

More information

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation Gas Detection Control Panel MX Analog and digital controller or 8 lines / 6 to s max Highly versatile controller Cost savings on wiring installation The Fixed Gas Detection People www.oldhamgas.com an

More information

Q-SMART MODBUS KIT. Modbus Protocol & Parameters. Cod EN rev.a ed.08/2018. Q-SMART Software Version AE17

Q-SMART MODBUS KIT. Modbus Protocol & Parameters. Cod EN rev.a ed.08/2018. Q-SMART Software Version AE17 Q-SMART MODBUS KIT Modbus Protocol & Parameters Cod.001085120EN rev.a ed.08/2018 Q-SMART Software Version AE17 Index 1 Modbus Protocol on Q-SMART... 4 1.1 Broadcasting... 4 1.2 Data Protection... 4 1.3

More information

LCF Touch Modbus Datasheet Application Security Advice Caution

LCF Touch Modbus Datasheet Application Security Advice Caution LCF Touch Modbus Electronic Fan Coil Thermostat with Touch Display (Flush mounting) Datasheet Subject to technical alteration Issue date: 3.11.214 Application Modern design flush mounting fan coil room

More information

RS485 MODBUS Module 8AI

RS485 MODBUS Module 8AI Version 1.4 15/04/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

ACCURATE ELECTRONICS INC

ACCURATE ELECTRONICS INC ACCURATE ELECTRONICS INC Page 1 of 7 Model 108078 2 Sept 09 WWW.ACCURATE.ORG PO BOX 1654 97075-1654 8687 SW Hall Blvd 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 Practice Section 108078 Rev A

More information

VAP304 PRO INSTALLATION & OPERATION MANUAL

VAP304 PRO INSTALLATION & OPERATION MANUAL VAP304 PRO INSTALLATION & OPERATION MANUAL Panic Fire Duress Program Bypass Report Chime Test Memory B A D C Program Chime Panic Duress Exit Fire Report Bypass Memory Test Reset Password Exit Reset Password

More information

Fire Control Panel FS4000

Fire Control Panel FS4000 Fire Control Panel FS4000 INSTRUCTION MANUAL Revision 4/02.11 Contents 1. Introduction... 4 2. Terminology... 4 3. Function... 5 4. Technical features... 5 4.1 Fire alarm lines... 5 4.2. Current thresholds

More information

YOUR PARTNER IN FIRE & GAS DETECTION

YOUR PARTNER IN FIRE & GAS DETECTION YOUR PARTNER IN FIRE & GAS DETECTION OGGIONI s.a.s. Via Lavoratori Autobianchi, 1 - P.T.B. Edif.13/O - 20832 Desio (MB) Italy Tel.+39 0362 629135 Fax. +39 0362 622531 www.oggionisas.com - info@oggionisas.com

More information

GLD-30 Gas Leak Detector

GLD-30 Gas Leak Detector GLD-30 Gas Leak Detector Installation, Operation & Maintenance General: The Archer Instruments GLD-30 is an ambient air monitor, used to detect the presence of a target gas (or gases) and to alert operators

More information

Detection, Protection, Innovation

Detection, Protection, Innovation MX3 CONTROLLER MX 3 CONTROLLER Analog and digital controller or 8 lines / 6 to 32 s max Highly versatile controller SIL reliability CERTIFICATIONS Detection, Protection, Innovation Oldham SAS has more

More information

DiMM Unit. LST Digital Interface Monitor Module (LST-DiMM) MAN3109

DiMM Unit. LST Digital Interface Monitor Module (LST-DiMM) MAN3109 LST Digital Interface Monitor Module (LST-DiMM) MAN3109 TABLE OF CONTENTS: Page No. 1 Important Guidelines... 3 2 General Description... 4 Digital Interface Monitor Module... 4 3 Specifications... 5 Leader

More information

Fire Control Panel FS5100

Fire Control Panel FS5100 Fire Control Panel FS5100 INSTRUCTION MANUAL Revision 6/02.11 Contents 1. Introduction... 5 2. Terminology... 5 3. Function... 7 4. Technical data... 7 4.1. Modules... 7 4.1.1. Type of modules... 7 4.1.2.

More information

Oxygen (O2) Single-Point Gas Detection System

Oxygen (O2) Single-Point Gas Detection System Oxygen (O) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in oxygen (O) sensor, accepts one analog remote device such as a secondary gas sensor, temperature or humidity

More information

UniPOS Wireless Fire Alarm Control Panel VIT 01 WIRELESS FIRE ALARM CONTROL PANEL VIT01 INSTRUCTION MANUAL

UniPOS Wireless Fire Alarm Control Panel VIT 01 WIRELESS FIRE ALARM CONTROL PANEL VIT01 INSTRUCTION MANUAL WIRELESS FIRE ALARM CONTROL PANEL VIT01 INSTRUCTION MANUAL Revision 8/10.13 Instruction manual Page 1 1. 2. 3. 4. 4.1. 4.2. 4.3. 4.4. 5. 5.1. 5.2. 5.3. 6. 6.1. 6.2. 6.3. 7. 7.1 7.2. 7.3. 8. 8.1. 8.2. 8.3.

More information

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel Gas Detection Control Panel MX Analog and digital controller or 8 lines / 6 to s max Highly versatile controller SIL reliability Fixed The Fixed Gas Gas Detection Detection Experts People www.oldhamgas.com

More information

Gas Controller Module GC-06

Gas Controller Module GC-06 Page 1 Oct. 2015/2 Measuring, warning and controlling module for toxic, combustible and refrigerant gases and vapours. The gas controller series GC-06 is designed in accordance with the standard EN 50545-1.

More information

SEC 3500 OI- StatCast RS232 Gas Status Text Broadcast Configuration Manual

SEC 3500 OI- StatCast RS232 Gas Status Text Broadcast Configuration Manual SEC 3500 OI- StatCast RS232 Gas Status Text Broadcast August, 2006 Sensor Electronics Corporation 5500 Lincoln Drive USA (952) 938-9486 Table Of Contents: Intended Audience... 3 Purpose...3 Overview...

More information

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL.

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL. Page 1 / 15 Installation and user manual Page 2 / 15 Sira s.r.l. reserves the right to make modifications to this manual and the product described herein without prior notice. Sira s.r.l. shall not be

More information

ModBus DE-1 INSTALLATION AND USER MANUAL

ModBus DE-1 INSTALLATION AND USER MANUAL ModBus DE-1 INSTALLATION AND USER MANUAL INTESIS Software, SL Distributed by DURAN ELECTRONICA S.L Tomás Bretón 50 28045 MADRID, España duran@duranelectronica.com www.duranelectronica.com 2 2010 DURAN

More information

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual Revision 1.03 8 November 2013 JVA Technologies Ethernet General Purpose IO Technical Manual www.jva-fence.com.au Table of Contents INTRODUCTION...3 Scope and Purpose...3 Glossary...3 SPECIFICATIONS...4

More information

CO2 transmitters TRANSMITTERS TO DETECT CARBON DIOXIDE (CO 2 )

CO2 transmitters TRANSMITTERS TO DETECT CARBON DIOXIDE (CO 2 ) CO2 transmitters TRANSMITTERS TO DETECT CARBON DIOXIDE (CO 2 ) Measure carbon dioxide (CO2), carbon monoxide (CO) and temperature (T) Infrared measurement technology (NDIR) Automatic calibration eliminates

More information

Version Inc Series Digital Gas Detector/Controller. Operation Manual

Version Inc Series Digital Gas Detector/Controller. Operation Manual 6000 Series Digital Gas Detector/Controller Version 000.02 Operation Manual TABLE OF CONTENTS 1.0 2.0 3.0 4.0 5.0 6.0 General Description 1.1 Applications 1.2 Features 1.3 Outputs 1.4 User Interface Model

More information

Combustible Gas Detection and Control System

Combustible Gas Detection and Control System Combustible Gas Detection and Control System DESCRIPTION Gas monitor with built-in combustible gas sensor, wall-mounted, accepts inputs from remote devices such as other gas sensors, temperature or humidity

More information

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015 OPERATING MANUAL EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC DOCUMENT NUMBER IN35-03 Revised 15 May 2015 TORREY PINES SCIENTIFIC, INC. 2713 Loker Ave. West Carlsbad,

More information

GS100M Gas Detection Controller

GS100M Gas Detection Controller GS100M Gas Detection Controller GS100M 1 Zone Gas Detection Controller 1 Zone / Sensor Conventional Positive Safety IP44 EN61010-1 EN50270 FEATURES Single Zone Protection Positive Safety Option Detection

More information

ACTIVE INFRARED BARRIER

ACTIVE INFRARED BARRIER Although PROTECH provides high security indoor intrusion sensors for the military and government markets, our specialty is outdoor protection. Since we first introduced our PIRAMID outdoor dual technology

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The nvent RAYCHEM NGC-40 is a multipoint

More information

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63 Fire Extinguishing Control Panel FS5200Е INSTRUCTION MANUAL Revision 8/01.17 Instruction Manual Page 1 1. 2. 3. 4. 4.1. 4.2. 4.2.1. 4.2.2. 4.2.3. 4.2.4. 4.2.5. 4.2.6. 4.2.7. 4.2.8. 4.2.9. 4.2.10. 4.2.11.

More information

Air Check EX LEL Gas Monitor Instruction Manual

Air Check EX LEL Gas Monitor Instruction Manual Air Check EX LEL Gas Monitor Instruction Manual PureAire Monitoring Systems, Inc. 1140 Ensell Road Lake Zurich, Illinois 60047 Phone: 847-726-6000 Fax: 847-726-6051 Toll-Free: 888-788-8050 www.pureairemonitoring.com

More information

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2 Features Integrated (built-in NO2 sensor / detector (Electro chemical sensor type Measuring ranges 0-10 ppm, 0-20 ppm or 0-30 ppm LCD display to show actual in ppm Status LED indication Normal operation

More information

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options

More information

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL Installation and Operation Manual 2 GG-2 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The Raychem NGC-40 is a multipoint electronic

More information

SCAN20 Series Gas Detection Controller

SCAN20 Series Gas Detection Controller SCAN20 Series Gas Detection Controller USER S MANUAL Code Number 2071 1022 SCAN20 USER S MANUAL Code no. 2071 1022 Page 1/14 Foreword This manual is made for SCAN20 Controllers equipped with the software

More information

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

Rig Protector. Multipoint Critical Gas Detection and Monitoring System Rig Protector Multipoint Critical Gas Detection and Monitoring System Rig Protection Device Protecting Personnel from Hazardous Gases RC Systems has engineered and manufactured industrial electronic products

More information

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev. TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL Microener- Copyright 2010 FW 2.1 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection

More information

Danfoss gas detection Controller unit

Danfoss gas detection Controller unit Data sheet Danfoss gas detection Controller unit The gas detection Controller Unit is used for a centralized monitoring and warning of hazardous gas concentrations. The input signals for the controller

More information

FIRECLASS Networking. Addressable Fire Alarm Control Panels From Software version 21. Product Application and Design Information FC-A-FCNET-A

FIRECLASS Networking. Addressable Fire Alarm Control Panels From Software version 21. Product Application and Design Information FC-A-FCNET-A FIRECLASS Networking Addressable Fire Alarm Control Panels From Software version 21 Product Application and Design Information FC-A-FCNET-A Doc. version 1 23. March 2012 FIRECLASS. Hillcrest Business Park,

More information

S5000 Gas Monitor. GMS5000.com

S5000 Gas Monitor. GMS5000.com S5000 Gas Monitor GMS5000.com A DETECTOR AS TOUGH AS YOU ARE... LOWER TEMPERATURE SPEC?... ARCTIC WINTERS IT HAS TO BE THE MOST RELIABLE PIECE OF EQUIPMENT OUT HERE IF THE DETECTOR DOESN T WORK, WE DON

More information

Operate the Mutli-Gas Monitor PID

Operate the Mutli-Gas Monitor PID TASK: Operate the Multi-Gas Monitor Learning Objective CONDITION: In a classroom environment, given a fully charged Multi-gas Monitor with the manufacturer operator s manual, all monitor components/accessories,

More information

M1000 Alarm Annunciator

M1000 Alarm Annunciator Data Sheet Alarm Annunciator Reliable Supervision and Control 10 inputs with LED indications Supports both NO/NC input contacts 10 open collector outputs Built-in siren relay Text label for alarm descriptions

More information

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1 Operation Manual Fighter ProVision Software Version: 0.0 Revision: 1 TABLE OF CONTENTS 1. Introduction 5 2. Software Installation 5 3. PC Users 6 3.1 Introduction 6 3.2 Default Code 6 3.3 Edit PC User

More information

P2267 NETWORK INTERFACE

P2267 NETWORK INTERFACE P2267 NETWORK INTERFACE USER MANUAL FOR OPERATING SYSTEMS: 22031-03 23636-01 October 2009 Associated Controls (Australia) Pty. Limited 2-4 Norfolk Road Greenacre, NSW, 2190. PH +61 2 9642 4922, FAX +61

More information

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system. Page : 1 of 17. ELAUSYS JA-KNX KNX Interface for Jablotron alarm system User Manual Document history Version. Date Author Comment 1.00 24-JUN-2017 NDE First issue 1.01 14-NOV-2017 NDE Support for user

More information

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

LINEAR HEAT DETECTION CABLE DURÁN-SAFE LINEAR HEAT DETECTION CABLE DURÁN-SAFE Installation & User Manual 2018 DURAN ELECTRONICA S.L. - All rights reserved www.duranelectronica.com I-manSAFECABLE-v05 TABLE OF CONTENTS Pages 1. INTRODUCTION...

More information

Ethernet General Purpose

Ethernet General Purpose Ethernet General Purpose Technical Manual Revision 1.03 8 November 2013 Pakton Technologies IO PAE224 Ethernet GPIO Manual.docx Page 1 of 22 Revision 1.03 Last updated 8/11/2013 Table of Contents INTRODUCTION...3

More information

3M Oldham MX 43 Controller

3M Oldham MX 43 Controller Description Fully scalable, and designed to functional safety performance level standards, the MX is an analog and digital controller that continuously measures and controls gases in the atmosphere. The

More information

QAS-101 SERIES SINGLE CHANNEL CONTROLLERS

QAS-101 SERIES SINGLE CHANNEL CONTROLLERS QAS-101 SERIES SINGLE CHANNEL CONTROLLERS INSTALLATION OPERATION AND MAINTENANCE MANUAL QUATROSENSE ENVIRONMENTAL LTD. 5935 OTTAWA STREET, PO BOX 749, RICHMOND, ONTARIO, CANADA. K0A 2Z0 PHONE: (613) 838-4005

More information

System 57. An advanced world of intelligent gas detection system management

System 57. An advanced world of intelligent gas detection system management An advanced world of intelligent gas detection system management A world of control technology High precision, intelligent control Master/voted alarm options High packing density Flexible I/O configuration

More information

User Manual. PolyGard Gas Controller MGC3. Two-Channel Analog Gas Controller Serial Number _E _0907. September 2007

User Manual. PolyGard Gas Controller MGC3. Two-Channel Analog Gas Controller Serial Number _E _0907. September 2007 PolyGard Gas Controller MGC3 Two-Channel Analog Gas Controller Serial Number _E _0907 User Manual September 2007 January 04, 2016 Revision Specifications subject to change without notice. USA 160104 Page

More information

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485 Select Option Device Wise Device/Group HumiLog Y-Axis Text Show/Hide Ledgends MIN MAX Scale Y Max 08-05-2015 15:17:59 PV_C PV_RH Color default default Graph Refresh Interval 2 Set Interval PV Low Alarm

More information